HomeMy WebLinkAboutGAS PIPING SCHEMATICBOARD OF
COUNTY
COMMISSIONERS
GAS PIPING SCHEMATIC
TANK SIZE: 500 GALS.
APPLICANCE — TYPE/SIZE
Al &4p-
A2 Po eu
A3 Tenkim- W&w ►Wttr
A4 SPe Nos fU
A5 t3bQ Si.ib
A6
PLANNING & DEVELOPMENT
SERVICES DEPARTMENT
Building and Code Regulation
Division
SCANNED
By
St, Lucie County
63,000 BTU
30 000 BTU
160.000 BTU
(00,000 BTU
(oD0017 BTU
BTU
PIPING LENGTH & SIZE
Ll 3S FT. 3/It.INCH DIA.
L2 5 FT.
W4 INCH DIA.
L3 Imo- S_FT.
3/4 INCH DIA.
L4 / a FT.
� INCH DIA.
L5__&_FT.
3/4 INCH DIA.
L6 Z FT.
3/4 INCH DIA.
L7 IS FT.
ilk INCH DIA.
1-8 Z FT.
3jµ INCH DIA.
L9_-6__FT.
3/FINCH DIA.
L10 z FT.
3/ F INCH DIA.
1-11 FT.
INCH DIA.
L12 FT.
INCH DIA.
Revised 7/22/14
(PIPE SIZE WAS TAKEN FROM
THEBcFUEL GAS CODE —
TABLE 402 (_))
ST. LUCIE COUNTY BUILDING DIVISION
REVIEWED FOR MPLIA CE
REVIEWED BY /
DATE
PLANS AND PERMIT MUST BE KEPT ON JOB
OR NO INSPECTION WILL BE MADE.
Websfte: www stiudeco.00v
2300 Virginia Avenue - Fort Pierce, FL. 34982-5652
Phone (772) 462-1553 FAX (772) 462-1578
�l ,w ICJ
!s
�H
4
g
W
Custom Home
oneThe Hinkle Residence
ervicsa, ina f9�13s4as 2469imtvl Or. FaR FImc. PL 31949
ME
N FT
�A KINGFlSHER WATERWAY
.>• 56 S87'08'47"E
W+ a
E 80.00,
FENCE TIE
(0.1' WEST) b CONIC ,
SCALE : 1"=30' _ N 05GL j}ub-EAWALL
Jr ;
jj�� Df+
- I
wveAl:u I�
�+NAI I�
FE
FENCE TIE)
` 22' IOFFSEI)e
((
E
/�Ip� �(
0
37.5' b
(EAST
g' (0.3 NORTH )
.1 �YE3T
111 i )
ri
LOT 10
(NO WELL FOUND) Ld
PROPOSED
RESIDENCE
22.5' 12.0'
n
FFE=5.56
O
a b
a
PROPOSED
FFE=1B
no LOT 8
**NOTE** .M-
¢
IF\,
qqp
b
N.— (NO WELL FOUND)
CITY W LE
C5
a 1
K
n d,
0 FFE=6.60
to
OPOSED !r7
SEPTIC SYSTEM N
615 SO FT O
....____.._� Z
?
0.0'
COVER _
'u
FENCE c, TIE
( 15 �lI -
S TC wW
Oct
36.2' 00
J O_
T 11r a�
VW_UNE
.Soot I pOH BIIVII DRIVE ''B� 4.
ASPHALT
FIID
SP KE (NOOID)
_
V[.1g1T (60 RAW)
PNQA^
668.72'
TMr PROJECT BENCHMARK
LEGEND
SET NAIL/TIN TAB (NO ID)
EL=4.23 1988)
A • aEMRAI M¢E
(NAVD Q4-g
.R • CURVE RAM
tTsl,9
L = CURVE LENGTH
CERTIFIED TO: oo_9xu's
`a`i eP�T
DONALD G. HINKLE AND UNDA J. HINKLE
MD - FORID
R 5/9' WON ROD
P - 1/2' RON PPE
DESCRIPTION
NU : p FUR FIGHT
ON - COI1CIRX MONIIMmT
LOT 9, BLOCK 3, CORAL COVE BEACH SECTION 1, ACCORDING TO THE PLAT THEREOF,
mE - UNSH RmR EuvAnav
AS RECORDED IN PLAT BOOK 11, PAGE. 30. OF THE PUSUC RECORDS OF
No - MAO NFNL AND InsL
ST. LUCIE COUNTY, FLORIDA.
P2s • Rmvfl'ov PIO RSONA' LU1D R
IS . U01503 eURNESS
SAID LAND CONTAINS 0.20 ACRES, MORE OR LESS.
P.B. • PUT ROOK
-
Idaalec
SURVEY NOTES
SWAY
0
® a `W�NDMPPRROPµE TANK
1. This survey is not valid without a signature and original embossed sealof a Florida
® - EXISTING SmnC TANK
Professional Land Surveyor.
OO - AT&T PEm &
2. Desenption provided by client and/or their agent.
® - wAM NUIER
3. The lost date of field work was October 3, 2018.
cps - Noce "M Pau
4. Underground Improvements and foundations were not located as part of this survey.
0 - MUE ITLEVISON BON
5. Bearings shown hereon are based on the North R/W line of Bimini Drive, bearing
NB7'08'47'W, as monumented. All beorings•are relative thereto.
-11- • PRWOR3D WATER SEHNCE
6. All boundary information shown is calculated per plat, unless otherwise shown.
O - MO Re sme
7. The proposed residence Iles In Flood zone 'X' and 'AE-5', per map 12111CO181 J.
CONo • COFFOREHE
doted 2-16-12.
so - 15 Rw Roo
8. Additions or deletions to survey maps or reports by other than the signing potty or
aU.E - DnANACE Ax0 uTlurr rASTAMr
so R. souvU REr
parties is prohibited without written consent of the signing party or parties.
-K- - V (MEN IM FENCE
9. All elevations shown are based on the North American Vertical Datum of 1985 (NAVD
-LT- - s' WOOD MOE
f aRR) t
NACU Nalnl ANEFUvN MUM DAIRS
LAxps SHOWN xmEox HERE xm Aernumm FaR wart rc WAYS, �' /
RESERMnRe, AGRDm21S A!ID/al FAsaYm" aF RECQ✓D. svCH i ['YL
RraWAnW. zt
6 OMER. SKann BE ®OUNE0 AND a RTFNEV BY BY:
mmes TROUGH APFROPRarE nnE va0urlal. RIDH H1I f'.. I AVFNTU�. FLORIDA P.I. NSana
"".... -
-
BOUNDARY SURVEY
PREPARED FOR
DONALD & LINDA HINKLE
REF. JOB NO.
DRAWN BY
DATE
DRAWING
NO
LAVENTURE & ASSOCIATES, INC.
PROFESSIONAL SURVEYING AND MAPPING
2552 PETERS ROAD, SMITE D
LB 7056 (n21 3ga 6 3PHONE RIDA �n2I 398-6426 FAX
18.3186
MINH
10/4/1e
18.3186
F.B..PG.
ALCULATED B
SCALE
SHEET NO.
18-252/40-41
RCL
1'=30'
1 OF 1 -
Anvwoco.
AtrAv=*z PYvPAft COMPMY
.
■ Corrugated stainless steel tubing (CSST) gas piping systems will be bonded
in accordance with Section G2411.1 (310) of the Florida Building Code and
0I 2 .
■ Underground gas piping will be installed at a minimum depth of 12 inches
below grade in accordance with Section G2415.12 (404.12) of the Florida
Building Code and NFPA 58.
■ Polyethylene pipe will be installed in accordance with 6.11.4 of NFPA 5$
and the Florida Building Code.
■ Carbon monoxide monitors will be installed prior to inspection and will
meet all code and safety requirements of NFPA 54 and the Florida Building
Code.
Compact First Stage Regulators
LV3403TR
Application Materials
Ideal for use as a first stage regulator on Orly domestic size ASME or
DOT container In propane gas installations requiring up to 1,500,000
BTU's per hour. The regulator Is factory set to reduce container -
pressure to an intermediate pressure of approximately 10 PSIG.
Features
• Compact design can be connected to a service valve using either
a POLadapler or a RegO product pigtail.
• Large threaded F.NPT bonnet vent can easily be piped -away
undergmund installations without the need of glue We or extra
adapters.
• NonAdjustable
• Large now orifice resists freeze ups due to water concentration In
LPG vapor.
• Design provides for good flow regulation at both high and low
container pressures.
• Built in relief valve and travel stop comply with NFPA 58 over
pressure requirements.
• incorporates 'A" F.NPT downstream pressure tap for an easy
Inllne check of the regulator's delivery pressure.
• Molded diaphragm provides an o-ring type seal betweefi the body
and bonnet
• Body and bonnet are assembled in the USA using the unique,
patented RegUlok seal system.
• Fully painted In brilliant red for complete corrosion protection.
• Mounting bracket avallable as an accessory: pad number 2302-31.
Ordering Information
Body.......................I...._.......................... .................... Zinc
Bonnet..........................................._..._.........._._.
.. ............................. steel
SpringDisc
..:................... ..... ........ ....... _...............Resitienl Rubber
Beat Disc ... ................
-••••-•Integrated Fabric and Synthetic Rubber
Diaphragm .:................I..... 9
e11M•. i97.4M ML MOM ,I1A' = 1JIDA9 r9]Ae0 IMp
fIOW?RarAaE
It. v_seo3-rRi I /.' I 9,
%' FNPT '/' FNPT10 PSIG ago 1,500,00
LY3403TRV9
O based on hdapw.s 2D PSIG higher Nan the mgubbree0ing end daWr3Y Pmssure 20%bwer NanN gWaoiyNnga�tltlegvery pre 9IYI rNan Ne Ifmg
M,*=
A14
dDO RagO De P..G.6ot 247 Efon. NC 21244 USA www.regopmduda.wm rhne (336)149-T70T Fax t336x 449o594 imma.
Designed to reduce rust stage pressure of 5 to 20 PSIG down to
burner pressure, normally 11' w.c. Ideal for medium commercial
Installations, multiple cylinder installations and normal domestic
loads.
Feallwes
• Large vent helps prevent blockage and has s:' F.NPT for vent
piping.
With 15 PSIG Inlet pressure, regulator Is designed to not pass
more than 2 PSIG with the seat disc removed.
Incorporates Integral relief valves.
• Replaceable valve orifice and valve seat disc.
• Stmight line valve closure reduces wear on seat disc.
• Unique bonnet vent profile minimizes vent freeze over when
properly installed. ,
• Large molded diaphragm is extra sensitive to pressure changes.
• Built In pressure tap has plugged 1r8" F.NPT outlet Plug can be
removed with a 3/16' hex alien wrench.
Select brown finish.
Body.......................... .......... .... _... .............. ...... Die castZ ric
Bonnet.:......:............................................................Dla Cast Zinc
NozzleOrifice .... :... ,—............... ....................................... Brass
.. Steel
Valve
....lv........_...................................................
Valve Seat Disc ......- .. .......... _......... ::_............. Resilient Rubber
Diaphragm ....................•• Integrated Fabdc and Synthetic Rubber
LiSTEa
_ a e
Mounts directly to house line piping. Eliminates need for union joints, u
elbows, and mounting brackets. Quick and easy to Install. d
O
• 8win"I design
Mmd,.5,.b8redcn 10 PSIG Mad Mmy P...
nab..
W
19f403BSeztes
oiwQROMMMMMM
.
_ -imommm----
t\.
titiM��m��m
minim
��irr
1�F
,�
n
A 6• 100Reg0Dr. P.O.api247EbNNC27244USA Fa1335)449e594R?E6Q
Capy(ighl 2017 National Fire Platedol A Odabm(NFPA®). Ucemec, eemem, for Ndvidual use aM clv ioacl on 12/372017 to knoncas to ,stoo we( final Pear. No other repmductiot or t2nsnusslon in any
Iona pemAaed waho, ipanyissimof NFPAO.Fm MLgdeswtomportumuthaHzeduw.= _.1sing.pa.olg.:
Chapter 16 • Pipe and Tubing Sizing Tables
,1
r
TABLE 16.1(n) Polyethylene flask P1pe-ll S
Gas: Undiluted -Propane
Inlet Pressure: 10.0 psig
Pressure Drop: LOpsig
Specific Gravity: 1.52
Plastic Pipe Y, in. '/<in: 1 in. 11/.in. Pb in. 2 in.
Length SDR 9.33 S SDR 11 SDR Il SDR 11 SDR 71
30
2140
2390
7740
13420
20300
36400
40
1840
3670
6630
11480
17300
31200
50
1630
3260
5870
10180
15400
27600
60
1470
2950
5320
9220
13900
25000
70
1360
2710
4900
8480
12800
23000
.t1,
1260
530
4560
789D
11900
21400
9
1180
2370
4270
740D
11200
20100
100
1120
2240
4040
699D
10600
19000
125
990
990
3580
620D
9360
16800
150
897
897
3240
5620
8480
15200
175
826
826
2980
5170
7800
14000
200
778
778
2780
4810
7260
13000
225
721
721
260
451D
6810
12200
250
681
681
2460
426D
6430
11600
275
646
646
2340
405D
6110
11000
300
617
617
2230
386D
5830
10470
350
567
567
2050
355D
5360
9640
400
528
528
1910
330D
4990
8970
450
495
495
992
310D
4680
8410
500
468
468
937
293D
4420
7950
600
424
424
849
265D
4010
7200
700
390
390
781
244D
3690
6620
800
363
363
726
227D
3430
6160
900
340
340
682
213D
3220
5780
1000
322
322
644
1201D
3040
5460
1500'- _
258
258
517
933
1616
4390
2000
221
221
443
499
1383
3750
IPS: Iron Pipe Sim.
SDR: Standard Dimension Ratio
Notes:
(1) Capacities are in 10DO Btu/hr.
(2) Dimensions in parentheses are inside diameter.
II
2017 LP -Gas Code Handbook
I
N
Table P-7B Propane
Maximum
Capacity ofTracPipe CSST in Thousands of BTU per Hour Propane Gas
,
Min Gas Pressure,., 12 74 R t, iq w.c-
Pressure Oros:.=2A
(Based on a 152 Specific Gravity/ 2520 BTU per cubicfoot Gas)
Tubing Length (feet)
`
r 5 10 15 20
t 40 50 .7,5:. °. 100
r 200 250
300
400
500 600 700
:00 900
1000
1100
1200 .t 1400
1500
3/8' 15 190 138 114 100
89
82 71 65 59 54 52 49 46 41
38. 33 30
27
24
22 19 17
17 16
16
14
14 13 13
13
{172"
19
4D..'.,
306
':252,
,2� 18,.
, 1�96
', .79
757'
:139
128"116
.
-111
°704„
_�
100
s 0
F
90-,
82'b
71'
-�63 "
S9
'�51,';
q6
41"=,
38
, 36'
, 3,- 5
3, 2
3.0
30�
-28-
27
�-
147
374
25
1069
763
625
545
488
'446
388
348
318
285
277
261
249
222
204
177
158
146
127
112
103
95
90
B4,
81
76
73
71
68
66
31
1846'
1309
707,?�
'933
836;
'765h
`663"
' 95
543'
]5'
�,..�r.?
488,:'
n�eisry
^t+,r..^'.a�'
445
;423.
„ 1
380'
u.!��.'
'.34T
^3
:269.'
247
'214'
792
176`
��n
'163
F-..rv.
752
.�s.r-i-
;'702
+.rov-
136'
-
130
125-
.d20�'116
w.s
,l11.
1" '
39
3469
2467
2022
1756
1574
1438
1249
1119
1023917
888
838
796
712
652
567
507
464
402
361
329
306
287
271
2S6
245
234
225
217
211
TM>r-^r
--t
r„^^-
.SJ
'4023
32772
a1834
2532'
,2si08
197T
128i
,1626
.a.:m
1452'
-,..�...*#'.-'.^-^'^_-.av+W^-.-.^^r^.q46e
Y406
1325
=1256
123"
"'i02�
,885f
2020
63
556
507T�
.469.
[439�
;441-3,
39L
z4;
,358
..33
*331=
31BS
2°
62
13073
9259
7568
6558
5869
5361
4645
4158
37973398
3290
3703
2945
2635
2407
2085
1867
1704
1477
1322
1106
1118
1047
986
936
893
855
822
792
763
Notes: WD(Equivalenl Hydraulic Diameter) Athearebw she which reflects the hydraulic pederm enee ofthe whims. It not a true phpical measure. Thu number is used to compare indhiduei sizes between different manufactwes
Do higher the END number the greaterthe flaw eap dtirofthe piping.
l
Table P-2 Propane Medium Pressure
_
Maximum Capacity ofTracPipe CSST in Thousands
of BTU per Hour Propane Gas
Min.6as Pressure: 13 t4 r m W.0
.PreSttae OroPi. "2S-�,iltw.c::
(Based on a 152 Specific Gravity/2520
BTU per cubic foot Gas)
Tubing
Length (feet)
r 25 3D 40 50 60 70
75 .t 90 100 125
150
200 250
300
400 Soo
°ea
700
SOO
900 1000 1100
t 2QO 1300
1400
ISOD
3/8" 15 222 159
131
114 102 93 81 73 67 62
60 58 55 52 46
43
36 33
30
27 24
22
21
19
17 17 16
-16 14
14
14
S7/2e
19
4 :
353'
290:
'0254�
t288
209`
.182
,1W'150
: 140
135^;
'731
'124
" 118'
. 10_8:
97
85 .
-76
70
57 :
51=..
46-
43
.40r
38,
36
35
33
-32
30,
30�
3/4°
25
1192
850
698
606
545
497
432
388
355
329
318
309
291
277
249
226
198
177
161
141
127
116
1106
100
95
90
'85
82
79
76
73
1:;-,
31
2512:
.i8b3
1720
{;1343
7106:976
883..
$25
`771^
....._
779
;^'-m
696
.>*-r
673
�`632.
T596'
. 533'
.4)0
r398.
;352-
^u-
320
aa..^-
339.
-a-o--
214
,m...,..:.,..�..,
196 ;'
182,
h-..-,.0
169`-160
T..._
,...,..:
1SL
-..�..
'746
139
133''128
.
125
I "
39
3870
2753
2256
1959
1756
1605
1393
1249
1142
1058
1023
991
936
888
796
728
632
567
518
450
402
367
340
320
301
287
272
261
252
242
234
1=v''
'46
.rz-^-s
6393,
aq�a^g
4503
ri-*-
386&
,m..-x�
'3173=
+u�c
"2834
..,�r�-
t25B4
rt.,.-.
22i4
_
5
_
'182
-^-sa
�fws
„-,•..-;a
,1626
..-,,.a.
'1S74,'1484
a+.,
<-,+s-e^
;14%,
>,-a-.:w^+
1256',
^^-'r
'1145
-""-Rr
`990,
--'i•
"885
'B06
�.am'
69P
�^-r
622
;-.-.»tee,
568,
.--�
5�,26
.-s .
4971
,�,aa
A42=
am-
439'
41$
«a«ax-
q01:
s-rv�
3�BSyj
-.-,.m
,370
�«;.� .:
"358.-
2e
62
14609
10347
8456
7329
6558
5990
5192
4645
4243
3930
3797
3676
3467
3290
2945
2688
2331
2085
1905
'1650
1477
1349
1249
1168
1102
1047
997
955
918
885
855
'Nowsx Tabledabovelndude foist lorfouo9 ogreabeMsandtwoend fiNngs. TubingrurnwlM urgernumbenof bendsandlerfittingishapbelneremed bythe equlvalentlengthaftubing woe kenowing eguelion:
a 13 n where L h the addhiomi le ngth of tubing and n is Ne number of add clonal fif W gs anWar bm dL
1
Quality Steel Corporation AG/UG Propane Tanks
keotr.
145D 'n). AND LIP
AAYU Anntrrr-unl ininyr Inlnrrani imnYAr,/I IGt VFSSFL DIMENSIONS AND SPECIFICATIONS .
WATER
CAPACITY
DIAMETER
(OD)
HEAD
TYPE
OVERALL
LENGTH
OVERALL
HEIGHT
. LEG*
WIDTH
LEV*
SPAM
WEIGHT
(lbs.)
**QUANTITY
FULLLOAb
PER STACK
*120 wg.
24"
Ellip.
5'-8"
3'
1'-11/2"
2 31f "
or 3•]i
260
108) 96
16 12
*250 wg.
3011
Hemi.
7'-10"
3'-8"
1'-5"
4'-11"
480
54
9
*320 wg.
30"
Hemi.
9'-7"
3'-S"
i'-51,
5
620
45
9
500 wg.
• 371/2"
Hemi.
10'
4'-2"
1'-8"
5
` 950
37 1 30
81 6
1000 wg.
41"
Hemi.
16,
4'-5"
1'-8"
101•1"
1,800
17115
6 15
1450wg.
461/2"
Ellip.
17'-4"
4'-11"
1'-9"
11'•7"
2,650
12
4
1990wg.
461/2"
Ellip.
23'-11"
4'-11"
1'-91..
16'
3,520
S
4
Dimemlons and sped0ations shown are appmxlmate. Individual vessels mayvary.
•Legspacmg+/-2". Leg widths and spacing may vary based on mfg. location. Check with yoursalespeson for details. 120,250,320wg. standard tanks
-no holes in legs (one center hole an request). 500 and 10DO wg. standard tanks -2 holes 16" on ceder. 145owg. and up as shown above.
--Full load and stack quantities vary by shipping location. Check with your salesperson for details.
General Specifications
- Conforms to the latest edition of ASME Rules for Construction of PressureVessels, Section Vill, Division 1.
Complies with NFPA 58. "
Rated at 250 psig from -20" F to 125" F. All vessels registered with National Board.
-Two serviceoptions available:
Option 1: Ready -to -bury underground option, coated with either powder coated phenolic epoxy finish.
or liquid applied epoxy primer coat followed by urethane top coat, supplied with composite
AG/UG dome.
Option 2: Aboveground option, coated with either powder coated TGIC polyester finish or liquid
applied epoxy primer coat followed by urethane topcoat, supplied with steel AG/UG dome.
-Ali vessels are shipped vacuum pre -purged to enable simplified first fill of the vessel.
Updated June 30, 2015
sLV. CABLE W/
CLAMPS TO
(PULLED
ANCHOR STRAP
e
CLAMPS TO
(PULLED -
UNDERGROUND .TANK HOLD DOWN DETAIL
GENERAL NOTES:PER
1. HELICAL ANCHORS SHALL HAVE AN ALLOWABLE PULL-OUT CAPACITY AS SHOWN B ANCHORS SHALL BE INSTALLED WITH
ANnunR aIAtj&MlbRER.TO ACHIEVE STATED LOAD CAPACITY. CAPACITY VARIES WITH SOOILI[ TYPE. VERIFY ANCHOR CAPACITY WR
(iA `T11NK`....•. 654
CHECK NOR LNOERGROjfNp `.UTILDTE$ PRIOR TO ANCHOR INSTALLATION
LOCATION OF TANK RELATIVE qTO ADJACENT STRUCTURES AND FEATURES ARE DEPENDENT UPON LOCAL CODES AND IS THE
]NSIBILTTY OF OTHERS. "
THE. -TANK AS SHOWN l'IAS. BEEN DESIGNED TO PREVENT FLOTATION, COLLAPSE, OR LATERAL MOVEMENT DURING THE BASE
I. EVENT"
O COPYRIGHT 2016 - FAIM ENGINEERING. LLC
AMERIGAS
PA , DAT ' Consulting Engineer $40111 - CA28108 _-_-^