Loading...
HomeMy WebLinkAboutLETTER - WINDOWSBRADEN 6 BRADEN, A. I. A., P. A. 7rchilech & 'Planners 417 COCONUT AVENUE, STUART, FLORIDA 3499B TELEPHONE: [772) 2B7-B25B FAX (772) 297-92B3 #AAC-000032 March 12, 2019 St. Lucie County Building Department Permit #: 1812-0316 RE: Wynne Bldg Corp. 6466 Alamendra To whom it may concern, Please note, The windows for this project shall be impact rated. There shall be no shutters installed. If you have any questions please feel free to call me at (772) 287-8258. Than , 1 R. Braden AIA Braden & Braden AIA PA r, BRADEN 6 BRADEN, A. I. A., P. A. '�Irchdech & 'Planners 417 COCONUT AVENUE, STUART. FLORIDA 34998 TELEPHONE (772) 287-8252 FAX [7721 2B7-82B3 #AAC-000032 FIB Product Approval Submittal Affidavit Opening Schedule Swing Doors, Overhead Deers, Sliding Dwr% Windows & Skylights Opening Type NOA/FL NUMM Product Model y Manufacturer Glass Attachment method T��Tratton Date pr'e%v�'e of Approved Teats 1,2,3 t4 FLa 239.3g Single Hun SH-l00 Impact PGT 5/IG' I/4' Ga eapewu a/ ma I /$' peneaaaon to be ®=ddgapp1duptarc t pproya incp°r ap=.V'am w F 80.0 PSF A IG-0330.02 Overhead Garage Door Motif[824/9Ir v-4 max. width Ic'-o• sax hoghht DAB •„R„ a s• wi artfflrm a�..w 10-9-21 + 50.0/-40.0 par B FLa I4414.1 Fiberglass Desi n Pro/ SD h Pro Jeld=Wen Eko 1/Y din. "n a 1.3 avbedrn6 et 3' wx . aor^ars °"� I1..r C.C. • tt;Z ar m hoed and ,00hs. + 50.0 PSF C FLa 251.5 Sliding Glass Door Series TWO SGD PGT I' mom Type °G5A° v4' da ta�c�s v wie. 1 t3/4C panaaa"WO.M epacad ait"Met apprava onaactar sore w era 2 1%2 ,adgo cb=r s paafud m Product approval + G0.0 PSF Product NOA/PL NUMBER Model 11 Manufacturer Attachment Method TT���f %5p .tioa Date Design Premature of Approved Teats MulllOn9 FLa 2G1.1 1' x 2 3/4' x .315' PGT Inebll yyar fastener tgpa and swings sheen m Table IA and IS �n III. c approval on sheet 5 2. ± 58.0 PSF lZOpf FLa IIL51.12 SV Crimp Metal Roofing Gulf Coast Supply and manufacturing 2G a Sv enm metal r�fmg ar,tachad to pigeood dock uang et9 x is' oac� scrams mt�r wV rang usher at 1Y ee. sax ,posing wet ASTm D (tgpa 2) 30 Ib raa un"debsent mut-ed with sin. 4 was legs and V end We f stanad with noon r aslant sin mps and lip 1.25' sing shame net epaae �Lµm at an�tee etamgeraa teas 12 me. in rbkt Attach aacx using a techaent datm 011 root pin — 108.5 PSF Siding Stucco on Block Soffit FLa 12198.3 Nadel T4 12' vented Vinyl Soffit Kaycan Install using 2' x 2' battens at L' ac. scraaad to soffit rraming usng ae ; 3' mood fcrema at each trues Install tit to battens asap +55.0/-35.0 PSF Hurricane Panels I have reviewed the above and approved it by my seal below. ( Architect or Engineer of Record ) WYNNE BUILDING CORPORATION 8000South U.S. #1 Suite 402 Port St. Lucie, FL 34952 Spanish Lakes Communities Division Port Saint Lucie April 9, 2019 To: St. Lucie County Building Department Attn: Permitting and/or Plan Review Re: 6466Alemendra Permit # 1812-0316 To Whom It May. Concern:. 0o G�� Miami Division Miami In regards to the above property, the mobile home that was located on the lot was moved off the property by the homeowner. If you have any questions I can be reached at (772) 878-5513. Thank you, AA ,Cheri.Lynn Adams Permit Coordinator Telephones: Port Saint Lucie (772) 878-5513 Miami (305) 235-3175