FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE WINDSOR IMPACT
Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR
Permit Office: ST. LUCIE COUNTY
SCANNED
City, State, Zip: FT. PI RCE , FL,
c3lz
11 (''�
��`
Permit Number:
BY
Owner:
� 1
Jurisdiction:
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate fteLwie County
1. New construction or existing
New (From Plans)
9. Wall Types(1432.0 sqft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1224.00 ft2
b. Frame - Wood, Adjacent
R=11.0 208.00 ft2
3. Number of units, if multiple: family
1
c. N/A
R= ft2
4. Number of Bedrooms
3
d. N/A
R= ft2
5. Is this a worst case?
Yes
10. Ceiling Types (1753.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1753.00 ft2
6. Conditioned floor area above grade (ft2)
1753
b. N/A
R= ft2
Conditioned floor area below grade (ft2)
0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(151.4 sqft.) Description
Area
a. Sup: Attic, Rat: Attic, AH: Attic
6 250
a. U-Factor: Sgl, U=0.63
111.36 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.65
40.00 112
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A
ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A
ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth:
2.850 ft.
Area Weighted Average SHGC:
0.239
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1753.0 sqft.)
Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation
R=0.0 1753.00 ft2
b. Conservation features
b. N/A
R= ft
None
c. N/A
R= ft
15. Credits
Pstat
Glass/Floor Area: 0.086
Total Proposed Modified Loads: 51.96
PASS
Total Baseline Loads: 53.66
1 hereby certify that the plans and specifications covered by
Review of the plans and
STq?�
this calculation are in compliance with the Florida Energy
specifications covered by this
pF-fNfi
0Code.
calculation indicates compliance
with the Florida Energy Code.
!~ ruu�+k -:, ,'a`;'•'.:•• O
PREPAR D Y:
Before construction is completed
r
DATE:
this building will be inspected for
compliance with Section 553.908
* c
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with theFloridaEnergy Cade.
C'Op WE
BUILDING OFFICIAL:
DATE \� �`
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
4/16/2018 6:31 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
Vr1RM RdnF_7017
PROJECT
Title: WYNNE THE WINDSOR IM Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1753
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225
Street:
THE WINDSOR
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fart Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1753 14024
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1 MASTER BEDROO
224 1792 No
0
1
1
Yes
Yes
Yes
2 WIC
63 504 No
0
1
No
Yes
Yes
3 MASTER BATH
56 448 No
0
1
Yes
Yes
Yes
4 M.BATH
61 488 No
0
1
Yes
Yes
Yes
5 LAUDRY
36 288 No
0
1
No
Yes
Yes
6 BEDROOM 2
180 1440 No
0
1
1
Yes
Yes
Yes
7 DINING/GREAT R
588 4704 No
2
1
Yes
Yes
Yes
8 KITCHEN
209 1672 Yes
0
1
Yes
Yes
Yes
9 BATH
50 400 No
0
1
Yes
Yes
Yes
10 HALL
25 200 No
0
1
No
Yes
Yes
11 FOYER
92 736 No
0
1
Yes
Yes
Yes
12 BEDROOM 3
169 1352 No
0
1
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
MASTER BEDRO 37 It 0
224 ft'
____
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC t ft 0
63 ft'
____
0 1
0
3 Slab -On -Grade Edge Insulatio
MASTER BATH 8 ft 0
56 ftz
____
0 1
0
4 Slab -On -Grade Edge Insulatio
M. BATH 7 ft 0
61 ft'
___
0 1
0
5SIab-On-Grade Edge Insulatio
LAUDRY 1 ft 0
36 ft'
0 1
0
4/16/2018 6:31 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
F(1RM Rdr15-9r117
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 12 8
0
180 ft2
----
0
1
0
7Slab-On-Grade Edge Insulatio
DINING/GREAT 50 It
0
588 ft2
----
0
1
0
8 Slab -On -Grade Edge Insulatio
KITCHEN lift
0
209 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio
BATH 5 ft
0
50 ft2
-_--
0
1
0
10Slab-On-Grade Edge Insulatio
HALL 1 it
0
25 112
----
0
1
0
11Slab-On-Grade Edge Insulatio
FOYER 9 ft
0
92 ft2
----
0
1
0
12SIab-On-Grade Edge Insulatio
BEDROOM 3 14 ft
0
169 112
----
0
1
0
ROOF
/
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V
# Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1 Gable or shed Composition shingles 1847 ft2
292 ft'
Light
0.5
No
0.9
No
0
18.4
ATTIC
/
V
# Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented)
MASTER BEDRO
30
Blown
224 ft2
0.1
Wood
2 Under Attic (Vented)
WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented)
MASTER BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented)
M. BATH
30
Blown
61 ft2
0.1
Wood
5 Under Attic (Vented)
LAUDRY
30
Blown
36 112
0.1
Wood
6 Under Attic (Vented)
BEDROOM 2
30
Blown
too ft2
0.1
Wood
7 Under Attic (Vented)
DINING/GREAT
30
Blown
588 ft2
0.1
Wood
8 Under Attic (Vented)
KITCHEN
30
Blown
209 ft2
0.1
Wood
9 Under Attic (Vented)
BATH
30
Blown
50 ft2
0.1
Wood
10 Under Attic (Vented)
HALL
30
Blown
25 ft2
0.1
Wood
11 Under Attic (Vented)
FOYER
30
Blown
92 ft2
0.1
Wood
12 Under Attic (Vented)
BEDROOM 3
30
Blown
169 ft2
0.1
Wood
WALLS
Adjacent
Space Cavity Width
Height
Sheathing Framing
Solar
Below
1
NE=>W Exterior Concrete Block - Ext IndMASTER BE
4.1 16
0 8
0
128.0 ft2
0
0
0.5
0
2
SW=>E Exterior Concrete Block - Ext InSNASTER BE
4.1 7
0 8
0
56.0 11:2
0
0
0.5
0
3
NW=>S Exterior Concrete Block - Ext InddASTER BE
4.1 14
0 8
0
112:0 ft2
0
0
0.5
0
4
NE=>W Exterior Concrete Block - Ext InEMASTER BA
4.1 8
0 8
0
64.0 112
0
0
0.5
0
4/16/2018 6:31 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
Space
-5
NE=>W Exterior
Concrete Block - Ext InsuM. BATH
4.1 7
0
8 0
56.0 ft'
0
0
0.5
0
-6
NE=>W Exterior
Concrete Block - Ext InSEDR00M 2
4.1 12
0
8 0
96.0 ft'
0
0
0.5
0
-7
SW=>E Exterior
Concrete Block - Ext InMNING/GRE
4.1 30
0
8 0
240.0 ft2
0
0
0.5
0
-8
NW=>S Exterior
Concrete Block - Ext InMNING/GRE
4.1 20
0
8 0
160.0 ft'
0
0
0.5
0
_ 9
SW=>E Exterior
Concrete Block - Ext InsuKITCHEN
4.1 11
0
8 0
88.0 ft'
0
0
0.5
0
_ 10
NE=>W Exterior
Concrete Block - Ext Insul BATH
4.1 5
0
8 0
40.0 ft'
0
0
0.5
0
11
SE=>N Exterior
Concrete Block - Ext Insul FOYER
4.1 8
0
8 0
64.0 ft'
0
0
0.5
0
12
SW=>E Exterior
Concrete Block - Ext Insul FOYER
4.1 1
0
8 0
8.0 ft'
0
0
0.5
0
_ 13
NE=>W Exterior
Concrete Block - Ext InREDROOM 3
4.1 13
0
8 0
104.0 ft'
0
0
0.5
0
_ 14
SW=>E Exterior
Concrete Block - Ext InMEDR00M 3
4.1 1
0
8 0
8.0 ft'
0
0
0.5
0
15
N=>SW Garage
Frame - Wood BEDROOM 3
11 26
8
208.0 ft'
0.23
0.5
0
DOORS
# Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 SE=>N Insulated FOYER
None
.39
3
3
6 8
21.7 ft'
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/
Wall
Overhang
V
# Ornt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 NW=>S 3
Metal Low-E Single Yes
0.63 0.25
N
32.4 ft'
1 It 0 in
1 it 4 in
Drapes/blinds
Exterior 5
2 NE=>W 5
Metal Low-E Single Yes
0.63 0.25
N
6.9 ft'
1 ft 0 in
1 It 4 in
None
None
3 NE=>W 6
Metal Low-E Single Yes
0.63 0.25
N
16.2 ft°
1 It 0 in
1 It 4 in
None
None
4 SW=>E 7
Metal Low-E Single Yes
0.63 0.25
N
39.8 ft'
1 ft 0 in
1 ft 4 in
None
None
5 NW=>S 8
Metal Low-E Single Yes
0.65 0.21
N
40.0 ft'
8 ft 0 in
1 ft 4 in
None
None
6 NE=>W 13
Metal Low-E Single Yes
0.63 0.25
N
16.2 ft'
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 806 ft' 806 ft'
26 ft
8 ft
11
INFILTRATION
# Scope Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82
168.92.
.2698
7
4/16/2018 6:31 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/
Split
HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.85
1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1
Electric
None
Garage
0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart
# Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft'
DUCTS
--- Supply --
— Return --
Air
CFM 25
CFM25
HVAC #
#
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 250 ft'
Attic
65 ft' Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programablre'Thermostat:
CApr[[eiling Fans:
Cooling
jjY
[[ ]]
May [[ ]]
[[ ]]
[ ]
[[ ]j
Nov
Dec
Heat
Jan [X] Feb
IX] Mar
Apr
Jun [X] Jul
May
[X] Aug
Sep
LJ
[rX�]
Nov
H Dec
Venting [ 1
l J
Jan [[ ]] Feb
[[X]] Mar
[ lXl Jun [[ ]] Jul
[[ ]) Aug
EX]
) Sep
ll�xll
Oct
[X]
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
4/16/2018 6:31 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall. be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind ninong and widna
Shower/tub
The air barrier installed atexterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electricallphone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
4/16/2018 6:31 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2
7. Windows"
Description
a. U-Factor:
Sgl, U=0.63
SHGC:
SHGC=0.25
b. U-Factor:
Sgl, U=0.65
SHGC:
SHGC=0.21
c. U-Factor:
N/A
SHGC:
d. U-Factor:
N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
THE WINDSOR, FT. PIERCE, FL,
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1224.00 ft2
b. Frame - Wood, Adjacent
R=11.0
208.00 ft2
1
c. N/A
R=
ft2
3
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
Yes
a. Under Attic (Vented)
R=30.0
1753.00 ft2
1753
b. N/A
R=
ft2
Area
c. N/A
R=
ft2
111.36 ft2
11. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: Attic
6 250
40.00 ft2
12. Cooling systems
kBtu/hr
Efficiency
ft2
a. Central Unit
34.8 SEER:15.00
ft2
13. Heating systems
kBtu/hr
Efficiency
a. Electric Heat Pump
34.8
HSPF:8.50
2.850 ft.
0.239
Insulation Area
R=0.0 1753.00 ft2
R= ft2
R= ft2
14. Hot water systems
a. Electric Cap: 40 gallons
EF: 0.97
b. Conservation features
None
15. Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant featuLes.,
Builder Signature:Date:
Address of New Home:sl \Apk�,�,,a City/FL Zip - 7�VQQ
�, -3(-A-li5
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/16/2018 6:31 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
-F - wrightsoft- Project Sumlrnary
Enure House
.QUICK CALCS, INC.
For. WYNNE DEVELOPMENT
THE WINDSOR, FT. PIERCE, FL
Notes:
\,-( � \
Design Information
Weather.
Winter Design Conditions
Outside db 42 OF
Inside db 70 OF
DesignTD 28 OF
Heating Summary
Structure
18467
Btuh
Ducts
6190
Btuh
Central vent (0 cfm)
0
Btuh
(ne )
Humidionfication
0
Btuh
Piping
0
Btuh
Equipment load
24657
Btuh
Infiltration
Method
Construction quality
Fireplaces
Fort Pierce, FL, USA
Simplified
Average
Heatingg Coolingg
Area (ft2) 1753
1753
Volume (fta) 14741
14741
Air changes/hour 0.38
0.20
Equiv. AVF (cfm) 93
49
Heating Equipment Summary
Make Carrier
Trade CARRIER AIR CONDITIONING
Model 25HBC536A`030
AHRI ref 7914585
8.5 HSPF
34600
Btuh @ 47OF
0
1160
cfm
0.047
cfm/Btuh
0.50
in H2O
point = 34 OF
Backup:
Input - 7 kW, Output = 23009'Btuh, 100 AFUE
Job:
Date:
By:
Summer Design Conditions
Outside db
90
OF
Inside db
75
OF
Design TD
15
OF
Daily range
L
Relative humidity
50
%
Moisture difference
61
gr/lb
Sensible Cooling Equipment.Load Sizing
Structure
17655
Btuh
Ducts
9340
Btuh.
Central vent (0 cfm)
0
Btuh .
(none)
Blower
0
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Equipment sensible load
25645
Btuh
Latent Cooling Equipment
Load Sizing
Structure
2453
Btuh
Ducts
2554
Bfuh
Central vent (0 cfm)
0
Btuh
(none)
Equipment latent -load
5007
Btuh
Equipment total load
30652
Btuh
Req, total capacity at 0.70 SHR
3.1
ton
Cooling Equipment Summary
Make Carder
Trade CARRIER AIR CONDITIONING
Cond 25HBC536A"030'
Coil FX4DN(B,F)037
AHRI ref 7914585
Efficiency 12.0 EER,
15 SEER
Sensible cooling
24360
Btuh
Latent cooling
10440
Btuh
Total cooling
34800
Btuh
Actual 'air flow
1160
cfm
Air flow factor
0.043
cfm1Btuh
Static pressure
0.50
in H2O
Load sensible heat ratio
0.84
Calculations approved byACCA to meet all requirements of Manual J ath Ed.
Wr19htSOft' RightSuite® Universal 2017 17.0.14 RSU08101 2017 Apr 10 1 Page 1
...k CalcslDocuments\WYNNE-THEWINDSOR-REVISED.mp Calc=MJS Front Dwrfaces: N 0
wrightsoft RighWg Worksheet Job:
Entire House Bate`
sy:
QUICK CALLS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-4666796 Email: OUICKCALCS@AOL.COM
1
Room name
Entire House
MASTER BEDROOM
2
EKposed wall
153.0 ft
46.0 ft
3
Room height
8.4 ft d
8.0 ft heat/cool
4
5
Room dimensions
Room area
1753.0 ft2
1.0 x 280.0 ft
280.0 ft2
Ty
Construction
U-Value
Or
HTM
Area (w)
Load
Area (fN)
Load
number
I
(BtulJfti°F)
(Stub/W)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Etuh)
Heat
I Cool
Gross
WP/S
Heat
Cool
Gross
WP/S
Heat
Cool
6
13A4ocs
9Actom
1Aclom. ,
0.143
1.270
-- 1:270
ne
ne
ne
.400
3556
35.56
2.55
70.43
i 70.43
488
7
' 16
448
0
0.
1795
.247.
581
1141
. 498
; .:1151
192
0
0
192
0.
0
769
0
, 0
489
�- , '0
- 0
11
' "
W
�--D
Welomo
13A4ocs
IWO
0.143
no,'
as
35.56
4.00
'45.24
255
` 16
64
0
41
' 581
165
739
105
` r ;0.
0
t
0
- ,. 0..
0
.� '. O
0
11D0
13A4ocs''•.
0.390
0.143-,svv
se
1092
.. 400
11.31
>255
23
,'437.
23
396
248
1684'
257
1.,1007
0
58
0
56
0
. 224
0
' S443
Vy
�C
'4PS2om
,0.770
sw
21.56
'V.53
,41
- 45
�893
i1140
0
0
0
�0
�11
I---G
13A40cs
1Ac1cm
0.143
1.270
nw
nw
4.00
35.56
2.55
45.24
290
33
217
0
867
1162
551
1478
112
33
79
0
318
1162
202
1478
�--G
P.: .
4A5-2omd,
'd2C-0sw` '• ' ...
0.770
0.091
,,nw
-
21.56
; 2.55
36.90
1:28
41
:.. 308
0
.. - 308
880
" 784
1505
l: '; ,. 395
0
.� : 0
, 0
, - .. 0
0
, ' . 0
0
,.0
C
16A30md
0.032
-
0.90
2.32
1753
1753-
1571
4067
280
280
- 251
65D
F: .:22A4p1
.,.
'..0.989
:..-:
27.89
0.00
1753-
153-
4237:
0
- 280.
..45
:1246
.., .. 0
6
c)AED excursion
1360
600
Envelope lass/gain
15594
15MI
13970
3561
12
a) infiltration
2873
810
809
228
b) Roomventilation
0
0
0
0
13
Internal gains: Occupants @ 230
Appliances/other
2
460
1000
0
0
0
Subtotal (lines 6 to 13)
18467
17655
4779
3789
Less fademal load
0
0
0
0
14
15
Less transfer
Redistribution
Subtotal
Duct loads
34%
53%
0
0
18467
6190
0
0
17655
9340
34%
53%
0
0
4779
1602
0
0
3789
2D05
Total room load
Air required (cfm)
24657
1160
26995
1160
6380
300
5794
249
A 4id- WrightsoR- Right -Suite® Universal 201717.0.14 RSU08101
...k Calcs\DocumentslWYNNE-THE WINDSOR-REVISED.rup Cale =MJ8 Front Door faces: N
2017-Apr-10 17:19:28
Page 1
+ wrightsoft• Right-M Worksheet deb:
Entire House Date:
QUICK CALC8, INC. By.
317 ST. LUCIE LN., FT. PIERCE, FL 34M Phone: 772466-6799 Fax 772-466-6796 Emil: OUICKCALCS@,AOLCOM
1
Roomname
WIC
M. BATH
2
E-osed wall
0 ft
7.0 ft
3
Room height
6.0 ft heat/cool
8.0 It heat/cool
4
5
Room dimensions
Room area
7.0 x 9.0 it
- 63.0 ft-
1.0 x 61.0 ft
61.0 ft2
Ty
Construction
number
U-value
(BtuNft2-°F)
Or
HTM
(Btutvft2)
Area (ftj
or pedmeter (ft)
Load
(Btuh)
Area (ftj
a perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
WKS
Heat
Cool
Gross
NIP1S
Heat
Cool
6
V
-
13A4ocs
1Aclom
`1Actom
0.143
1.270'-.ne.
1.270
ne
. ne
4.00
3556
- 35.56
2.55
-.70.43
: 70.43
0
10.
0
0
0
0
0
0
0
0
.0
0
56
7'
. 0
49
"0.
r 0
196
247
0
126
488
. 0
11
V!/
LD
1Ac1cm
13A4acs
1.270
0.143
•'ne
se
'35.66
4.00
45.24
2.55
- 0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11D0
0.390
0.143-SW
se
1092
400
11.31
.- 255
0
.0
0
0-
0
- 0
0
.0
0
' 0
0
- 0
0
- -0
0
-0
,:•1344ces--
L=C
4A5-2am
-0.770
sw.:
21:56
27.53
0
0
0
0
0
o-
--0
ro
V)/
13A-0ccs
0.143
nw
4.00
255
0
0
0
0
0
0
0
0
1Ac1cm
1.270
nw
35.56
45.24
0
0
0
0
0
0
0
0
---CG
4A5-2omd
0.770
nw
21.56
36.90
0
0
0
0
0
0
0
0
'P.
-12C-0sw
0.091
.-
.'2.65
1:28
0
0
0
0
- 0
0
- ._0
- .0
C
16A-30md
0.032
-
0.90
2.32
63
63
56
146
61
61
55
142
F
22A4pl ..
0.989
-.
27.69
0.00
..63
0,
0',
0
. '.61
.7
194...
'0
6
c)AED esnursion
-5
-26
Envelope loss/gain
56
141
692
729
12
a) Infiltration
1 0
0
126
35
b) Roomventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Applianceslother
0
0
Subtotal pines 6 to 13)
56
141
817
764
Less elderid load
0
0
0
0
Less transfer
0
0
0
0
RedistdlxNon
0
0
0
0
14
Subtotal
56
141
817
764
15
Duct loads
34%
53%
19
7.51
341/6
53%
274
MX
Total room load
75
216
1
1091
1168
Air required (cfm)
4
9
51
50
A 4fl- wrightsoft, 2017-Apr-1017:19:28
Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2
...k CaIcsIDocumenta WYNNE-THE WINDSOR-REVISED.mp Cale =MJS Front Door faces: N
+# wrightsoft• Right -A) Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By:
317 ST. LUCIE LN., FT. PIERCE. FL 34946 Phone: 772-466-6799 Fa c 772-466-6796 Email: OUICKCALCS@AOLCOM
1
Room name
IAUDRY
BEDROOM
2
F)q)osed wall
0 ft
12.0 ft
3
Room height
8.0 It heat/cool
8.0 R heat/cool
4
Room dimensions
6.0 x 6.0 It
15.0 x 12.0 ft
5
Room area
36.0 ft'
180.0 fl'
Ty
Construction
U-value
Or
HTM
Area (ftj
Load
Area (fP)
Load
number
(Btuh/ftMF)
(Btuh/ftl
a perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
WP/S
Heat
Cool
Gmss
WP/S
Heat
Cool
6
_
13A4ocs
0.143
ne
4.00
255
0
0.
0
0
96
80
319
203
1Actom
-1.270
- no.
-35.56
- 70.43
0
0
0
'0
" 0'
' : -0
- .0
- 0
dAol m
1.270
ne
35.56
70.43
0-
0
- 0-
'0
- '.16
'0
SBT
1151
1Ac1om, '
1:270
. no
35.55
45.24
0
0
- 0
0
0
0
0
. -0
11
Uy
�D
13AAccs
0.143
as
4.00
265
0
0
0
0
0
0
0
0
11D0
0.390
se
10.92
11.31
0
0
0
0
0
0
0
0
LW/ ;
Imo-^
'13A4ads,
0.143
-sw
' 4.00
.., 255
0
0.
0
0
- . 0:
• 0
- 0
4AB-2am '.
:. 0.770>sw
. 21.56
., 27.53
0
o
A
0
0
o
:o
13A-0acs
0.143
nw
4.00
255
0
0
0
0
0
0
0
0
1A-c1om
1.270
nw
35.56
45.24
0
0
0
0
0
0
0
0
4A5.2omd
0.770
nw
21.56
36.90
0
0
0
0
0
0
0
0
P"-:
�12C-0sw -
0.091
-
2:55
1:28
0
.0
0
0:•
0
. 0
:-0
0
C
16A-Wmd
0.032
-
0.90
2.32
36
36
32
84
180
180
161
418
F
22A-tpl ..
- 0.989
-
27.69
0.00
36
. 0
0
' 0
180
12
- 332
• - : - 0
6
c)AED excursion
3
-60
Envelope loss/gain
32
81
1394
1711
12
a) Infiltration
0
0
216
61
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants Qc 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
32
81
1609
1772
Less eMemal load
0
0
0
0
Less transfer
0
0
0
0
RedisMbution
6
14
6
14
14
Subtotal
38
95
1615
1786
15
Duct loads
34%
53%
13
so
34%
53%
541
945
Total room load
51
145
2166
2730
Air required(cfm)
2
6
101
117
�A •+ i- wrightsoTt• Right -Suite® Universal 201717.0.14 RSUD8101
... k Cetcs\DocumentslWYNNE-THE WINDSOR-REVISED.mp Calc = MJ8 Front Doorfaces: N
2017-Apr-10 17:19:28
Page 3
wrigtitsoft• Right-M Worksheet Job:
Entire House Date:
QUICK CALLS, INC. By:
317 ST. LUCIE LK, FT. PIERCE, FL 34946 Phone: 772-46M799 Fax 772d66-6796 Email: OUICKCALCS@AOL.COM
1
Room name
DINING/GREAT ROOM
WCHFN
2
E>Posed wall
50.0 ft
11.0 ft
3
Room height
8.9 It heaticool
8.9 It heaticool
4
Room dimensions
1.0 x 588.0 It
19.0 x 11.0 It
5
Room area
588.0 ft2
209.0 ft2
Ty
Construction
U-value
Or
HTM
Area (ftl
Load
Area (ft2)
Load
number
(Btuhlftx°F)
(BtuWft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
NIP/S
Heat
Cool
6
13AAocs
0143
ne
4.00
255
0
0
0
0
0
0
0
0
,1Aclom -
1270
ne
35.56
70.43
0
0
0
0
0.
0
0
0
slAclonn
1.270
ne.
`-:35.56
- 70.43
0
.. 0
0.
'0
0
0
0
0
;1Acian t.. ' .
` 1.270
ne
`35.56
45.24
0
0
r 0
.... 0'
.0
" ..: 0.
0
:.:..p
11
13AA=
0.143
se
4.00
255
0
0
0
0
0
0
0
0
11DO
0.390
se
1092
11.31
0
0
0
0
0
0
0
0
'�
13A4acs'
0. 143
•sw
4.OD
::. 2.55
267
226
. 903.:
574
-98
_ 98
'392
249
4A5.2an
.0.770
'sw
21.56
27.53
41
22
'893i.
1140
0
0
-0
13A-0acs '
0.143
nw
4.00
2.55
178
137
549
349
0
_-0
0
0
0
1Actom
1.270
nw
35.56
45.24
0
0
0
0
0
0
0
0
4A5-2o nd
0.770
nw
21.56
36.90
41
0
880
1505
0
0
0
0
P -
12C-0sw-
0.091
-2.56
1.28
- 0
0
0
0
116
116
295
148
C
18A30md
0.032
-
0.90
232
588
5a8
627
1364
209
209
187
485
F'
22A4p1 '
0.989
_
-'
27.69
. 0.00
588
50
` 1385
: 0
209
,.. 11
305
0
6
c)AED excursion
1004
S4
Envelope loss/gain
5136
5937
1179
818
12
a) Infiltration
1000
282
220
62
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
2
460
0
0
Appliances/other
0
100D
Subtotal pines 6 to 13)
6136
6679
1399
1880
Less e#emal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
6
14
D
0
14
Subtotal
6142
6693
1399
1890
15
Duct loads
34°/2
53%
20M
3541
340/6
53%
469
995
Total room load
8200
10234
1867
2876
Air required (cfm)
386
440
88
124
� Calculations approved bvACCA to meet all requirements of Manual J 8th Ed.
SEA -Fk wrights ft- RlghtSulteO Universal 2017 17.0.14 RSU08101 2017 Apr 10 1 c
...k CalcslDocumentslWYNNE-THEWINDSOR-REVISED.mp Calc=MJS Front Doorfaces: N Page 4
�+ wrlghtsoft, Right-M Worksheet Job:
Entire House Bate`
sy-
QUICK CALCS, INC.
317 ST. LUCIE LK, FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Emil: OUICKCALCS AOLCOM
1
Room name
BATH
HALL
2
Bq:osed wall
5.0 ft
0 ft
3
Room height
8.0 ft heat/cool
8.0 ft heat/cool
4
Room dimensions
10.0 x 5.0 ft
5.0 x 5.0 ft
5
Room area
50.0 W
25.0 ft'
Ty
Construction
U-value
Or
HTM
Area (ft�
Load
Area (ft
Load
number
etul*Vt -F)
(BtulvW)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
WP/S
Heat
Ccol
6
V
13A4ods
0.143
no
400
255
40
40
160
102
0
0
0
0
:1Aclom, -
1.270
'no -
, 35.56
- 70.43
0
D
0
,0
0
0
, '0
0
,1Aclom-
' 1:270
no
a 3556
.•70.43
0
0
0
. ' 01.
0;
. ..0,
. '0'
'0
�7Actom
1.270
'no
35.56
45.24
0
- 0
0
0'
.0,
0
0
0
11
W
�---D
laA4acs
0.143
se
4.00
255
0
0
0
0
0
0
0
0
11D0„
0.390
se
1092
11.31
0
0
0
0
0
0
0
0
yy .•,..13A4ocs
L=C'
.,,
;..0.143
sw
.' ,400
.. .2.55..
'0
& .. a,
,.. .0
� ." 0'
0:-�
0',.
•. � `0
4AS-2om
0.77o
sw
? 21.56
` 27.53
0
0
- 0
0
o
'- -. - 0
0
-0
YV
M41ocs
0.143
nvi
4.00
255
0
0
0
0
0
0
0
0
1Ac1om
1.270
nw
35.56
45.24
0
0
0
0
0
0
0
0
I{----GG
4A5-2amd
0.770
nw
21.56
36.90
0
0
0
0
0
0
0
0
P. -
12GUsw
0.091
-
2.55
"1.28
0
. 0
0
0
0.
0
- 0
, 0
C
16A-30md
0.032
-
0.90
232
50
5o
45
116
25
25
22
58
F -
22A4p1
0.989
-
27.69
' 0.00
50
5
138
: 0
25
0
- 0
.0
6
c)AED en:ursion
-8
-2
Ern lope loss/gain
343
210
22
56
12
a) Infi8ration
90
25
0
0
b) Room ventilation
0
0
- 0
0
13
Internal gains: Occupants C3 230
0
0
0
0
Appliances/other
0
0
Subtotal gins 6 to 13)
433
235
22
66
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
6
14
-22
56
14
Subtotal
439
249
0
0
15
Duct loads
34%
53%
147
1-M
34%
53%
0
0
Total room load
686
381
0
0
Air required (cfm)
28
16
0
0
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
h wrightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-1017:19:28
...1<CalcslDocumentslWYNNE-THEWINDSOR-REVISED.mp C21c=MJ8 Front Doorfaces: N
Page 5
+ wrightsoft• RighWO Worksheet Job:
Entire House Base:
sy:
QUICK CALCS, INC.
317 ST. LUCIE Lin., FT. PIERCE, FL 34946 Phone: 772A66-6799 Fax: 772-466.6796 Email: OUICKCALCS@IOL.COM
1
Room name
FOYER
BEDROOM 3
2
Exposed wall
9.0 ft
14.0 ft
3
Room height
8.0 If heaticool
8.0 ft heat/cool
4
Room dimensions
1.0 x 92.0 ft
13.0 x 130 ft
5
Room area
92.0 W
169.0 ft'
Ty
Construction
U-value
Or
HTM
Area (ft.)
Load
Area (ft2)
Load
number
(Btuh/ftMF)
(StUWft')
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heal
Cool
Gross
WP/S
Heat
Cool
Gross
WP/S
Heat
Cool
6
W
13A-0acs
0.143
no
400
255
0
0
0
0
104
88
351
223
1Aclom
%clom
1.270
1.270.
no
ne
3556
3556
70.43
.70.43
0
0
0
0
0
0
0
0
0
0
. 0.
0
0
.. 0.
0
-0
%V
I
1Xclon'
13A4ccs
1.270
0.143
ne
se
35.56
4.00
_ 45.24
255
0
64
0
41
" 0
165
+ 0
105
16
0
0
0
:581
0
'739
0
11DO
13A-0acs
aAszom + .
0.390
0.143
o.no
_ se
'sw
sw
1092
400
ztss
, 11.31
r . 265.
: " 27s3:•
23
- 8
o
23
-. '8
01
248
32
o
257
.. 20
, o
0
.. 8
. 0
0
'8
0
0
. 32
0
0
.. '=o
`D
-c
13A-00cs
1Actom
0.143
1.270
mrr
nw
4.00
35.56
2.55
45.24
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
P
4A5-2omd
,12C-0sw,j '
0.770
0.091
nw
21.66
2.55
36.90
1:28
0
.88
0
88
0
224
0
113
0
104
0
', .104'
0
265
0
..133
C
16AJ0md
0.032
-
0.90
2.32
92
92
82
213
169
169
151
392
F
32A4pl ' - -
0.989
- -'
27.69
. 0.00
, - 92
9
" 249
0
169
- 14
398
0
6
c)AED excursion
-25
-52
Envelope loss/gain
1002
684
1768
1455
12
a) infiltration
162
46
252
71
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
1163
730
2020
1527
Less mdemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
1163
730
2020
1527
15
Duct loads
34%a
53%
3W
386
34%
53%
677
808
Total mom load
1553
1116
2697
2335
Air required(cfm)
73
48
127
100
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrigfftsofY Right-Sulte® Universal 201717.0.14 RSUD8101 2017-Apr-10 1 Page age 6
...k Calcs\DocumentslWYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N
wrightsoftDuct System Summary
Entire House
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799Fax 772-466-6796 Email: OUICKCALCS@AOLCOM
For. WYNNE DEVELOPMENT
THE WINDSOR, FT. PIERCE, FL
External static pressure
Pressure losses
Available static pressure
Supply/ return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
Heating
0.50 in H2O
0 in H2O
0.50 in H2O
0.250 / 0.250 in H2O
0.273 in/100ft
1160 cfm
Job:
Date:
By:
Cooling
0.50
in H2O
0
in H2O
0.50
in H2O
0.250 / 0.250
in H2O
0.273
in/100ft
1160
cfm
183 ft
Name
Design
(Btuh)
Htg
(Cfm)
Clg
(Cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Mat]
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH
h 586
28
16
0.372
4.0
OxO
VIFx
19.5
115.6
st1
BEDROOM
C 2730
101
117
0.384
7.0
OxO
VIFx
15.0
115.0
stl -
BEDROOM3
'h 2697
127
100
0.353
6.0
Ox0
VIFx
26.8
115.0,nn;.st1
'.
DININGIGREAT ROOM
c 3411
129
147
0.292
7.0
OxO
VIFx
36.5
135.0
st2
DININGIGREATROOM-e
C 3411
129
147
0.371
7.0
OxO
VIFx
19.9
115.0
stl
DININGIGREAT ROOM
C 3411
129
147
0.278
7.0
OxO
VIFx
44.9
135.0
st2
FOYER
h 1553
73
48
0.490
4.0
OxO
VIFx
7.0
95.0
KITCHEN
c 2875
88
124
0.366
6.0
OxO
VIFx
21:8
115.0
stl
LAUDRY
c 145
2
6
0.371
4.0
OxO
VIFx
19.9
115.0
all
M•BATH
h 1091
51
.50
0.282
6.0
OxO
VIFx
42.3
135.0
st2
MASTER BEDROOM
h 3190
150
124
0.273
6.0
OxO
VIFx
48.4
135.0
st2
MASTER BEDROOM -A
h 3190
150
124
0.284
6.0
Ox O
VIFx
40.9
135.0
st2
wlc
c 216
4
9
0.292
4.0
0x0
VIFx 1
36.0 1
135.0
st2
Trunk
Htg
Clg
Design
Veloc
Diem
H x W
Duct
Name
Type
(cfm)
(Cfm)
FIR
(fpm)
(In)
pn)
Material
Trunk
st2
Peak AVF
612
602
0.273
780
12.0
0 x 0
VinlFlx
st1
all
Peak AVF
1087
1112
0.273
796
16.0
0 x 0
VinIFIX
t �J}r.- Wrl htSOtit• 2017-Apr-1017:19:29
r 9 RlghtSuite® Universal 2017 17.0.14 RSU06101 Page 1
...k CalosWocumenlslWYNNE-TfE WINDSOR-REVISED.mp Calc = MJB Front Door faces: N
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FIR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Math
Trunk
rb1
Ox0
1 1160
1160
0
1 0
0
0
Ox 0
1
VIFx
C wri ht5oft- 2017-Apt-1017:19.29
9 RightSuOe® Universal 201717.0.14 RSU08101 Page 2
... k Calcs%DocumentslWYMdE-THEWINDSOR-RMSED.mp Calc=MA Front Dooncces: N