Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Name: STERLINGNNE THE NE ENT BuildePermitrOffice:. Scq� Street: THE STERLING City, State, FT. PIE CE FL �NUCIE COUNTY Permit Number: co �` Zip: , E` G4C7ey Owner:�(� V„�b Jurisdiction: B Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) C'pUn 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types (1474.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1474.00 ft2 6. Conditioned floor area above grade (ft2) 1474 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH:. Attic 6 300 a. U-Factor: Sgl, U=0.63 101.25 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.239 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1473.5 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2 b. Conservation features b. N/A R= ft None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 48.34 PASS Total Baseline Loads: 48.53 1 hereby certify that the plans and specifications covered by Review of the plans and fliS SrgTe this calculation are in compliance with the Florida Energy specifications covered by this O� y „ _ O� Code. calculation indicates compliance l0 with the Florida Energy Code. f+ ++m"", ;'.:` ';''•` o PREPARED BY: Before construction is completed DATE: 41 1 i�7 this building will be inspected for compliance with Section 553.908 17 9 y ■ ° c I hereby certify that this building, as designed, is in compliance the Florida Energy Code. Florida Statutes. COb with OWNER BUILDING OFFICIAL: WE DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). l G ��4/17/2018 2:37 PM EnergyGauge® USA-FlaRes2 7 Se ti 4 .1 C�qF lt�.;i are pE� 2 2018 Page 1 of 6 FORM R405-2017 PROJECT Title: WYNNE THE STERLING Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 100 Street: THE STERLING Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M. BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 329 ft' ---_ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft' ---_ 0 1 0 3SIab-On-Grade Edge Insulatio M. BATH 8 ft 0 56 ft' -_-- 0 1 0 4SIab-On-Grade Edge Insulatio KITCHEN 1 ft 0 192 ft' ---- 0 1 0 5Slab-On-Grade Edge Insulatio BATH 5 ft 0 45 ft' ---- 0 1 0 6'Slab-On-Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft' _-_- 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft2 ---- 0 1 0 4117/2018 2:37 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8Slab-On-Grade Edge Insulatio LAUNDRY Eft 0 42 ft2 __ 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 ---- 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1553 ft2 246 ft' Light 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1474 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 329 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42ft' 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>SW Exterior Concrete Block - Ext InS®EDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 2 SW=>NE Exterior Concrete Block- Ext Ins®EDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext Insi3EDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 _ 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 6 NE=>SW Exterior Concrete Block - Ext InMEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 7 SE=>NW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 8 S=>N Exterior Concrete Block - Ext InfiffDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.6 0 9 SW=>NE Exterior Concrete Block- Ext InfiffDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 12 SW=>NE Exterior Concrete Block - Ext InsdIAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 13 NE=>SW Exterior Concrete Block - Ext Ins8REAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.6 0 14 NW=>SE Exterior Concrete Block -Ext lnsDREAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.6 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.6 0 4/17/2018 2:37 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 ononn Dnnr_')n17 DOORS # Ornt Door Type Space WidthArea Storms U-Value Ft Width In Ft 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal _ 2 SW=>NE 4 Metal _ 3 SE=>NW 7 Metal _ 4 NE=>SW 13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 0.63 0.25 N 32.9 ft2 1 ft 0 in 1 ft 4 in 0.63 0.25 N 6:9 ft2 1 ft 0 in 1 ft 4 in 0.63 0.25 N 24.0 ft2 6 ft 0 in 1 ft 4 in 0.63 U5 N 37.5 ft2 1 ft 0 in 1 ft 4 in 0.65 0.21 N 40.0 ft2 8 ft 0 in 1 ft 4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft2 315 ft2 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000366 1375.7 75.53 142.04 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr drn 0.85 1 sys#1 HOT WATER SYSTEM System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 F(1RM Ftdf7F_9(117 DUCTS / -- Supply — — Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 300 ft' Attic 75 ft= Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablre'Thermostat: Ceiling Fans: Heating Jan ]]Y [X] Feb Mar [ [) ] [ May[ May ] Jun [ ] Jul [[` ]J] Aug [X] ]Sep j L J Oct [�X Nov Nov Dec r[X,] Venting ( )Jan l l [[ ]) Feb X Mar [X] Apr [ 1 ] EX) )Jun EX) ]Jul [)Aug lX1 E 1 Sep lxl [X� [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/17/2018 2:37 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 2b* - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks orjoints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceilinglattic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind niping and wiring Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 4/17/2018 2:38 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. THE STERLING, FT. PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. WA R= ft2 4. Number of,Bedrooms 2 d.N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 1474.00 ft2 6. Conditioned floor area (ft2) 1474 b. N/A R= ft2 7. Windows" Description Area c. N/A R= ft2 a. U-Factor: Sgl, U=0.63 101.25 ft2 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft2 6 300 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft2 SHGC: SHGC=0.21 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor. N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency a. Electric Beat Pump 34.8 HSPF:8.50 Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.239 8. Floor Types Insulation Area 14. Hot water systems a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2EF: a. Electric Cap: 40 gallons b. N/A R= ft2 0.97 c. NIA R= ft2 b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. c/ Builder Signature: Date: Address of New Home.\ f'�V\C1�M14� (� D�l^ City/FL Zip *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 Project Summary Date: - wrightsoftEntire House By: QUICK.CALCS, INC. 317 Sr. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: 6UICKCALCS@AOLCOM Project• • For: WYNNE DEVELOPMENT THE CARLTO\N_299, FT. PIERCE, Fl- I� Notes: St <4�%YNFO Cp Design - Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 26 "F Design TD 15 OF Daily range Relative humidity L 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18188 Btuh Structure 17877 Btuh Ducts Central vent (0 cfm) 5654 Btuh 0 Btuh Ducts Central vent (0 cfm). 8536 Btuh 0. Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23842 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 25093 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2958 Btuh Ducts 2319 Btuh Central vent (0 cfm) 0 Btuh Area Heatingg Coolin�gg (none) . (ft2) 1474 1474 Equipment latent load 5277 Btuh Volume (ftJ 12227 12227 Air changes/hour 0.45 0.23 Equipment total load 30370 Btuh Equiv. AVF (cfm) 92 47 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment. Summary Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A•030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 33 OF 8.5 HSPF 34600 Btuh @ 47°F 27 OF 1160 cfm 0.049 cfm/Btuh 0.50 in H2O Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Make Caner Trade CARRIER AIR CONDITIONING Cond 25HBC536A'030 Coil FX4DN((B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actualair flow 1160 cfm Air flow factor 0.044 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. r wri9htsoft• RightSuite9 Universal 2017 17.0.14 RSU08101 2017-Apr710 17:14:53 .:.Wdghlsoft HVAC\WYNNE-THE GRAND CARLTON-298.rup CaIc=MJB Front Doorfaces: N Page 1 wrightsoft• Right-JO Worksheet Jab: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 7724666799 Fac 7724666796 Erred: OUCKCALCS@AOL.COM 1 Room name Entire House BEDROOM 2 3 =ad wall Room height 156.2 If 8.3 If d 52.0 ft 8.0 It heallcool 4 5 Room dimensions Room area 1473.5 ft' 1.0 x 329.0 ft 329.0 fP Ty nurriber (Stul✓11MF) Or HTM (Btuwft2) Am or perimeter (ft) (Btuh) or periArea meter (ft) (Bth) Heat Cool Gross WP/S Heat Cool Gross NIP/S Heat Cool 6 Vy LG 1344ocs JAo1om 13A-4ccs 0.143 _1:270 0.143 .ne . no se 4.00 . 35.56 4.00 - Z55 ' 70.43 255 479 38 128 - 442 � _ � 0 83 - 1768 - �1344 331 1124 .2662 210 - 80' _ ..0 0 80 0 0- 320 ";0 0 ' 204 i - -'0 0 W ��GD 1Aa1am 1.270 se 35.56 34.77 24 48 848 829 0 0 0 0 11 11DO 0.390 se 10.92 11.31 22 22 236 244 0 0 0 0 W W I--f :13A41oos 13AAocs 0.143 0.143 - a sw 4.00 4.00 255 2.55 34 360 34 353 136 1414 86 899 0 224 : 0 224 ' 0 897 0 670 1A-clan 1.270 sw 35.56 4291 7 11 247 298 0 0 0 0 13A4ocs 1Aclonn -0.143 1,270'nw nw., 4.00 . 35.56. ' 2.55 45.24 290- 33 217 0 .' 867 -' 1162 . 551 1476 112 33' 79 ' 0:.. ' 318 1162 202 ,; ,,1478 . ` 4A5.20m%.. -0.770 nw. 7 21.56 . 27.54 -41 0 :880 - 1124 ;- 0 0 ' 0 P 12C-Osw 0.091 - 2.55 1.28 192 192 489 246 0 0 0 0 C- A6A30md 0032. - 0.90 2.32 1474 1474. 1320. 3419 329 329 295 763 F 22A4p1 0.989 - 27.69 0.00 1474 156 4325 0 329 52 1440 0 6 c)AEDexcursion 784 1 6,80 Fsnelope loss/gain 15366 13954 1 4432 3997 12 a) Infiltration b) Room ventilation 2822 0 773 0 909 0 249 0 13 Intemal gains: Occupants @ 230 Appliances/other 5 115D 2000 2 460 0 Subtotal (lines 6 to 13) 18188 17677 5341 46D6 14 15 Less wdwnal load Less transfer Redistribution Subtotal Duct loads 31% 48% 0 0 0 18188 5654 0 0 0 17877 8536 31% 48% 0 0 0 5341 16M 0 0 0 460 2199 Total mom load Air required (cfm) 23842 1160 26413 1160 7001 341 6805 299 ,. Calculations approved byACCA to meet all requirements of Manual J 8th Ed A& -Fk wrlghtsoft- Right-SulteO UNversel 2017 17.0.14 RSUD8101 2017-Apr.1017:14:63 ...Wdghtsoft liVAG WVNNE-THE GRAND CARLTON-299.mp Cato =MJ8 Front Door faces: N Page t wrightsoft Right-M Worksheet Job: Entire House Date: ey: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 7724666799 Fax 772-466.6796 Email; OUICKCALCS cUi Of.COM 1 Room name WIC M. BATH 2 Bposed wall 0 ft 8.0 ft 3 Room height 8.0 ft heat/ood 8.0 ft heat/cod 4 Room dimensions 7.0 x 9.0 ft 7.0 x 8.0 It 5 Room area 63.0 ft' 56.0 ft' Ty Construction U-value Or HTM Area (III Load Area (ft-) Load number (Bluhffti`F) (Btulvft� or perimeter (ft) (Btuh) or perimeter (it) (stub) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cod 6 'W 1A-clom '1.270 + no 4.00 2.55 -a 0 0 0 0 � 0 0 ' �0 ' 1Ac1om 1.270 :no 35.56 �- :70.43' " - 0 0 0. ;0 0' � 0 '"0 ', b W, 13A4ocs 0.143 se 4.00 2.55 0 0 0' 0 0 0 0 0 �LGD 1Aaiom 1.270 se 35.56 34.77 0 0 0 0 0 0 0 0 11 1100 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W 13h4ccs - 0.143 s 4.06 255 0 .0 0 0 0 - 0 0 - 0 y/ 13A4ocs 0.143 sw 4.00 255 0 0 0 0 64 67 228 145 1210 ew 0 0 0 0 7 5 240 290 298 13AAcos �, - . 0.143 nw 400 2:55 0 ,0 0 .0 , 0 - .0 0 1Aclom w 1.270 my 35.56 45.24 :0 ' o.: ... 0' 0 -0' .,0 ' 0: ' - C0 'A tom". 'tzco -'0.770 0w.'.' 21.55 � .27.54 o 0 0. o o, o o o o.ost 255 tza 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 0.90 232 63 63 56 146 66 56 50 130 F 22A-td 0.989 - 27.69 0.00 63 0 0 0 56 8 222 0 6 c)AED excursion -2 225 Emlope loss/gain 56 145 747 798 12 a) Infiltration 0 0 140 38 b) Room.remlation 0 0 0 0 13 internal gains: Occupants Q 230 0 0 0 0 Appliances/other 0 0 Subtotal(Iines 6to 13) 56 145 887 836 Less exeRal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 14 Subtotal 56 145 8 36 15 Duct loads 31% 48% 18 69 31% 48% 276 76 39989 Total room load 74 214 1162 1235 Air required (dim) 4 9 57 54 Calculations approved byACCA to meet all requirements of Manual J 8th Ed 'd& -Fk- wrightsoft- RlghtSuiteO Universal 2017 17.0.14 RSUD81012017-Apr-10 17:14:53 ...Wrightsoft flUAC%WYNINE-THE GRAND CARLTON-299.rup Calc=MJ8 Front Doorfaces: N Page i wrightsoft• RighW@ Worksheet Job: Enure House pate: ay: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone; 772-4666799 Fax 772-4666796 Email: QUICKCALCS@AOLCOM 1 Room name KITCHEN BATH 2 FAQ ad wall 0 ft 5.0 ft 3 Room height 8.0 ft heat1cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 192.0 ft 9.0 x 5.0 ft 5 Room area 192.0 ft- 45.0 ft- Ty Con Or HTIVI AM I-) Load Area Load number st h/WF) (Btuwft-) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 ' 13A-0acs 0.143 ne 4.00 '' 2.55 0 0 0.. - 0 - 40 40 160 „ 102 9Aclom. - .1.270 ne, .35;56 70.43': 01' '-0:.. 0. .. 0 _'0. 0;' 0 .:. 0 I�13A4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 C 1Aciom 1.270 se 35.56 34.77 0 0 0 0 0 0 0 0 11 �D 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W -.'.13AAocs 0:143 - -s - .4.00 2.65 0 10 , 01. 0. 0 0 '0 0 1�1 13A-0ocs 0.143 sw' 4.00 255 0 0 0 0 0 0 0- 0 L-G 1Ac1om 1.270 sw 35.55 42.91 0 0 0 0 0 0 0 0 . ., 13A-4ocs.• 0143 nw, :. M 2.55 � � 0" � 0 � 0 0: `� 0 ..:^0 0 � �`0 1Ac1om," - 1.270 nw. 35.56 : 45.24 0 ,. 0 .� - 0 -' 0 0 r0 . 0 : ' 0 10.770 nw 21.56 27.54 0 0 0 ..:.. 0 .0 0 0 ,. "0 P 12C-0sw 0.091 - 2.65 1.28 64 64 163 82 0 0 0 0 C. 116A-30mcl 0.032 - 0.90 ' 2.32. 192 192 172 445' 45 '45 40 _104 F 22A-tpl 0.989 - 27.69 0.00 192 0 0 0 45 5 138 0 6 c)AED mursion -27 -2 Envelope loss/gain 335 501 339 204 12 a) Infiltration 0 0 87 24 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliancesfother 2000 0 Subtotal (lines 6 to 13) 335 2501 426 228 Less eMemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 .0 14 Subtotal 335 2501 426 228 15 Duct toads 31% 48% 104 1194 31% 48% 133 109 Total room load 439 3695 559 336 Air required (cfm) 21 162 27 15 Calculations approved bvACCA to meet all requirements of Manual J.8th Ed. wrightsoft- 2017-Apr-10 17:14:53 Aft Right -Suite® Universal 2017 17.0.14 RSUD8101 Page 3 ...Wdghtsoft HVAQWYNNE-THE GRAND CARLTON-299.mp Calc=MJS Front Door faces: N ►# wrightsoft' Right-J® Worksheet Date: Entire House Date By: QUICK CALCS, INC. 317 ST. LUCIE L . FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 2 ENTRY 2 ENwsed wall 32.2 ft 7.0 it 3 Room height 8.0 It heal/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 203.5 It 1.0 x 55.0 ft 5 Room area 203.5 It' 55.0 fl' Ty Construction U-value Or HTM Area (ft=) Load Area (ft5 Load number (Btuhlfli*F) (BtulVft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Ccol Gross WP/S Heat Coal Gross WP/S Heat Cool 6 13A-06cs - 0.143 --ne 4:00 ' 2.55 - 128 128 513 326 - , 0 0 . 0 - 0 1=G IA -clan:' - .1.270 . no 35.66 70.'43 0 0. -, 0 .' 01 0 0: ' ` 0 0 13A4ocs 0.143 se 4.00 2.55 80 56 225 143 48 26 106 67 1Actom 1.270 se 35.56 34.77 24 24 848 829 0 0 0 0 11 11DO 0.390 as 10.92 11.31 0 0 0 0 22 22 236 244 W 113440cs 0.143 s 4.00 - 255 34 - 34 136 86 0 0 .0 0 V�/ 13A-0acs 0.143 sw 4.00 255 16 16 64 41 8 8 32 20 L-G 1Ac1om 1.270 sw 35.56 42.91 0 0 0 0 0 0 0 0 VV 13Adacs., 0.143 nw 4.00 ... 2.55 0 ' 0 0 0. . 0. ... 0 10, -'0 4Abiom' : 1.270 nw l 35.56 45.24 0 0 . 0. . 0 .. ' 0 .0 0 .., . ;- 0 '4A5.20M 0.770 my 21.56 27.54 0 0' 0 0 0 0 0 - 'o P 12GOsw 0.091 - 2.55 1.28 0 0 0 0 72 72 183 92 C 1SAarad 0.032 - 0.90 2.32 204 204 182 472 55 65 49 128 F 22A4PI - 0.989 - 27.69 0.00 204 32 891 0 65 7 194 0 6 c)AED excursion -24 -6 Envelope losslgain 2859 1873 800 545 12 a) Infiltration 564 154 122 34 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 3422 2257 922 679 Less eMemal load 0 0 0 Less transfer 0 0 0 Redistribution 0 0 0 ]67 14 Subtotal 3422 2257 922 15 Duct loads 31°/ 48% 1064 1078 31% 48% 287 Total room load 4486 3335 12M 855 Air required(cfm) 218 146 59 38 Calculations approved byACCA to meet all requirements of Manual J 8th Ed wrllghtsoR- i Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-1017:14:53 A...Wdghtsoft WAC1WYNNE-THE GRAND CARLTON-299.mp Cale =MJ8 Front Door faces: N Page wrightsoft Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LA, FT. PIERCE, FL 34946 Phone: 772-066-6799 Fax 772A66-6796 Ernal: QUICKCALCS@ADLCOM 1 Room name LAUNDRY GREAT/DINWG 2 3 Exposad wall Room height 6.0 ft 8.0 it heaticool 46.0 ft 8.9 It heat/cool 4 Room dimensions 7.0 x 6.0 ft 1.0 x 488.0 it 5 Room area 42.0 fP 488.0 W Ty ConsWctim U-value Or HTM Area (fly Load Area (fl') Load number (Btulyfti*F) (BtuWft') a perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Coal 8 W " -0 0 0 � .0 '. 231 .194 775 ' r 493 ' tAclloom; , . . ; ..' ..1.2 0 no � . 35.56 •... 70.43 ' ly 13A-4= 0.143 se 4.00 255 0 0 0 0 0 0 0 0 11 II--GD 1A�lcm 11DO 1270 0.390 so se 35.66 10.92 34.77 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W ' W T-C i13A4ccs. 13A-0acs 0.143 0.143 s sw -.4.00 4.00 2.55 255 0. 48 0 48 0 192 - 0 122 0- 0 .0 0 : 0 0 ..0 0 1Aclom 120 sw 3556 42.91 0 0 0 0 0 0 0 0 13A4ocs`` ... 0:143 , nw 4.00 2.55 0 ; . 10 .0 0 . 178'; 7 137 : 549 . 349 .1Ac1om:'".. ..1.270 nw -. 35.56 °' .45.24 .0 0 0 • . 0 ` - 0 ; .0 . 0: •. , -- 0 4A5-2om: 0.7,0 nw - 21.56 .27.54 0 0. 0 0 41 0 860 ' 1124 P 12C-0sw 0.091 - 2.55 1.28 56 56 143 72 0 0 0 0 C 16A3Wnd 0.032 - 0.90 232 42 42 38 97 488 488 437 .1132 F 22A-Id 0.989 - 27.69 0.00 42 6 166 0 488 46 1274 0 6 c)AED excursion -3 -56 Envelope loss/gain 539 288 5259 5704 12 a) Orfiftration 105 29 895 245 b) Rcom vemilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal Qines 6to 13) 644 317 6154 6409 14 Less aMerrel load • Less transfer Redistdbution Subtotal 0 - 0 0 644 0 0 0 317 0 0 0 6154 0 0 0 6409 15 Duct loads 31% 48%u 200 151 31% 48% 1913 3060 Totalmoom load Air required(cfm) 844 41 468 21 8067 393 9469 416 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightoSoR• RlghtSoitelil Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:14:53 /�C�A ...Wrightsoft HVACIWYE-7HE GRAND CARLTON-299.rup Colo Front Door faces: N Page 5 M4 +- wrightsoftDuct System Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772A666799 Fac 772A666796 Email: QUICKCALCS@AOLCOM e-roject Intormation For: WYNNE DEVELOPMENT THE CARLTON 299, FT. PIERCE, FL External static pressure _Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow 'Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 cfm 176 Job: Date: By: Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (In) H x W (In) Duct Mall Actual Ln (ft) Ftg.Egv Ln (ft) . Trunk BATH h 559 27 15 0.376 4.0 OxO VIFx 18.1 115.0 SO BEDROOM 2 h 4486 218 146 0.374 6.0 OxO VIFx 18.6 115.0 st1 BEDROOM -A h 3501 170 '149 0.297 6.0 OxO VIFx 33.1 135.0 st2 BEDROOM-5 h 3501 170 149 0.284 6.0 OxO VIFx 41.1 135.0 st2 ENTRY h 1209 59 38 0.510 4.0 OxO VIFx 3.0 95.0 GREAT/DINING c 4735 196 208 0.318 7.0 OxO VIFx 22.4 135.0 st2 GREAT/DINING-B c 4735 196 208 0.307 7.0 OxO 'VIFx 28.1 135.0 st2 KITCHEN c 3695 21 162 0.375 7.0 OxO VIFx 18.3 115.0 Ed LAUNDRY h 844 41 21 0.366 6.0 0x0 VIFx 21.6 115.0 Gil M.BATH h 1162 57 54 0.366 4.0 OxO VIFx 21.6 115.0 st1 WIC c 214 4 9 0.310 4.0 Ox0 I VIFx 1 26.3 135.0 st2 Supply Trunk Detail Table Trunk Htg. Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 737 724 0.284• 689 14.0 0 x 0 VinlFlx st1 st1 Peak AVF 1101 1122 0.284 804 16.0 0 x 0 VinlFlx t Wrl htsaft' 2017-Apr-1017.14:64 �� 9 RlghiSulte® Univereal 2017 77.0.74 RSU06701 Page 1 ... Wrightsoft WAMYNNE-THE GRAND CARLTON-299.mp Cale = MJ8 Front Door faces: N Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 OxO 1 1160 1160 0 0 0 0 Ox 0 1 VIFx Awrl htSofC Ri2017-Apr-10 n:14:sa 9ghtSuite® Universal 2017 77.0.74 RSU08701 Page 2 ...WdghtsoR HVAC\WYNNE-THE GRAND CARLTON-299.mp Cato -MJ8 Front Door faces: N