Loading...
HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online Page t of 3 Y:.Iiy.ka'sa;'Yn h"V.yA')"3 cp,i'�-m'.&J 'J1 si 1 t I �1�i 1.?.l"mu.����sl-"±c.}-r�r'�� BEIS Home f Log In Use, Reglstretlon 1 Hot Topics 'S. Supmr surnarge Stan, a Fb¢s PuWotlons I ME Stan etl551te Map Line searN I ��I7Annca� T C S Ili r,I Product Approval 1 LC, ��.p ti USER: Poenc Later\\/. $ Fvoenn Aoo.vU Mmu > Pmo,, l or o,, c on Sea m a Annn[ennn Hst a AppuEluon Detail :x'e d5+r1""tis FL# FL17022-R7 ... ._...__.. Application Status Comments 08/18/2017v. date reapply 08/21/17 Archived I_,I Protluct Manufacturer Extreme Metal Fabricators, LLC Address/Phone/Email 2'60 SW Poma Drive OFTHE M SCANNED BY St. Lucie County Authorized Signature Richard McKuhen flvalldation@yahoo.com Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City, FL34990 ARRL�1�POSE WORK (772) 872-8034 114ESE F LANs dchard@emfab.net ARE SUI JECT TO ANY CORRECT[ NS Quality Assurance Represen[ate RF_QUIR -D BY B9t �1�TORS IAT ER T MAY B NECESSAR 6N y!Address/Phone/Email COMPL TCAIR&9 ODES. CALLAPP D Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report - Hardwpy Received Florida Engineer or Architect Name who developed the LOCKE BOWDEN Evaluation Report Quality Assurance Entity Keystone Certifications, Inc. ......_Quality Assurance Contract Expiration Date-__-------04/22/2024 Validated By Zachary R. Priest, P.E. PJ Validation Checklist- Hardcapy Received Certificate of independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated R17022 R7 COI FL 17022.1 5 V CRIMP ssr pdf Standard TAB 125 UL 1897 UL 580 Year 2603 2012 2006 ST. LUCIE COUNTY BUILDING DI N REVIEWED FOR CO PLIANCE Method 1 Option D REVIE D DATE Da/18i2017 PLANS AND PERMIT MUST BE KEP JOB 08/25i2017 SITE OR NO INSPECTION(S) WIL E MADE Florida Building Code Online Page 2I of 3 Date Pending FBC Approval Date Approved 08/28/2017 10/10/2017 FL # Model, Number or Name Description 17022.1 1 - "5V Crimp" (116) 26 Gauge steel, 3/8" rib height, 24' wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use In HVHZ: No FL17022 R7 U FL 17022.1 5 V CRIMP ssr.ndP Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports assembly In compliance with the installation method listed In this report and applicable code sections of FBC. Refer to manufacturer's Installation Instructions. 17022.2 12 - "5V Crimp" (R6) use in HVHZ: No use outside HVHZ: Yes Other: Refer to evaluation report for conciltIons.Install the assembly In compliance with the Installation method listed In this report and applicable code sections of FBC. Refer to manufacturer's Installation Instructions. 3 - "1.5" Mechanical Seam" (R5) Limits of Use Approved for use in HVHZ: No. 'Approved for use outsideHVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly In compliance with the Installation method listed In this report and applicable code sections of FBC. Refer to manufacturer's Installation Instructions. 17022.4 14 - "1.5" Mechanical Seam" IRS) Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistants No Design Pressure: +WA/ -Table A use. install me assembly in compliance with the Installation men listed In this report and applicable code sections of FBC. Refer to manufacturer's Installation instructions, 17022.5 1 5 - "1 In. Neil Strip" (RS) Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressures +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly In compliance with the installation method Ilstetl In this report and applicable code sections of FBC. Refer to manufacturers Installation Instructions. - "1 In. Nall Strip" (R5) Llrnits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No 'Design Pressure: +N/A/ -Table A Others Refer to evaluation report for conditions and limitations of use. Install the assembly, In compliance with the installation method listed In this report and applicable code sections of FBC. Refer to manufacturees Installation Instructions. - "1.5 _In: Nall Strip" IRS) 0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Installation Instructions FL17022 R7 11 FL 2 s Verified By: Locke Bowden, P.E. 49704 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with clips and fasteners. Installation Instructions 0 Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Parry: Yes Evaluation Reports FL17022 R7 AE FL 170223 1.5 MECHANICAL seam 24aa ssr.if Created by Independent Third Party: Yes ll 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof l � panel mechanically attached to 15/32" plywood or Wood Deck with clips and fasteners. Installation Instructions FL17022 R7 11 FL 17022.4 MECHANCIAL SEAM ALUMINUM ssrpd Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with FL17022 R7 D FL 17022.5 1.0 NAILSTRtP ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Parry: Yes Evaluation Reports FL17022 R7 AE EL 17022.5 1.0 NAILST rP ssr.odf Created by Independent Third Party: Yes 1" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanicallyattached to attached to 15/32" plywood or Wood Deck with fasteners, j Installation Instructions FL17072 R7 IT FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.ady Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7_ AE_FL 17022.6_ 1.0 NAIL STRIP 0.032 ALUM ssr.odf Created by Independent Third Party: Yes Florida Building Code Online Page 3 of 3 1.5" rib height, 19" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15132" plywood or wood deck with fasteners. Limits of Use Installation Instructions Approved for use In HVHZ: No FL17022 R7 I F ] 1.5 Nil Strip 26GA s' r. df Verlfled By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions and limitations of use. Install the assembly In compliance with the Installation method FL17022 R7 AE FL 17022.7 15 Nail Strip 26GA ssr odf Created by Independent Third Party: Yes listed In this report and applicable code sections of FBC. Refer to manufacturer's Installation Instructions, e plywood or wood deck with exposed fasteners. Limps of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL17022 R7 11 FL 177022.8 EMAX R'b ssr.ndf Verified By: Locke Bowden, P.E. 49704 Impact Resistanb No Created by Independent Third Parry: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions and limitations of FL17022 R] AE FL 177022,8 EIIAX Rib ssr odf use. Install the assembly In compliance with the Installation method Created by Independent Third Party: Yes listed in this report and applicable code sections of FBC. Refer to manufacturer's Installation Instructions. 17022.9 9 -" PBR MAX" IRS) 26 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Limits of Use Installation Instructions Approved for use In HVHZ: No Approved for use outside HVHZ: Yes R17022 R7 11 FL 17022.9 PBR RIB ssr odf Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressures +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions and limitations of FL17022 R7 AE FL 17022.9 PBR RIB ssr odf use. Install the assembly In compliance with the Installation method Created by Independent Third Party: Yes listed In this report and applicable code sections of FBC. Refer to manufacturer's Installation Instructions. oacR ne.t C.nind U}:: 2601 elnl, Stone Bond, Tallahassee R 32399 Phone: 850487-1824 The $doe of rlord. la an MEEO employ.. Ca..ftht 2002-2013 state of M,H4, :: M,on Statement :: A—sorlOn Statement :: RehnE Statement address Product Approval Accepan M-199M 1 M FL17022.1 6V Crimp (26GA Steel), 24" Wide Roof Panel -Details Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 61h ad. 2. Minimum slope to be compliant with Florida Building Code 2017 61h ad., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6t^ ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. Deck- - 15132'or greater Plywood, or -Nkadplank 24- 12" n n Panel Profile 12" O.C. I O.C. Fasten ' g x -1/2" Min. or #10 x 1-1/2" Min. per -table "A" Hex Wisher Head Screw Spaced 12" o.c. across the Panel Wdth Panel Referto Table "A" for Spacing Along Panel Overlap Length Deck- 15/32" or greater Plywood, or -Mod plank