Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT SC��nfED Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, F Permit Number: St' �UCIe Owner: U-AA0` (�D,�a,c7� �"" _ Jurisdiction: C OLIn Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1 1. New construction or existing New (From Plans) 9. Wall Types (1432.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1224.00 ft2 b. Frame - Wood, Adjacent R=11.0 208.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1763.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ft2 6. Conditioned floor area above grade (ft2) 1753 b. N/A - R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(151.4 sqft.) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 250 a. U-Factor: Sgl, U=0.63 111.36 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.239 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1753.0 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.086 Total Proposed Modified Loads: 51.96 PASS Total Baseline Loads: 53.66 1 hereby certify that the plans and specifications covered by Review of the plans and Sl1E 57, this calculation are in compliance with the Florida Energy specifications covered by this 04 Code. calculation indicates compliance with the Florida Energy Code. PREPA By* DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 v �� _ ' "- O - r y x I hereby certify that this building, as dsigned, is in compliance the Florida Energy Code.` Florida Statutes. COD with WE OWNER/AC�T �1 BUILDING OFFICIAL: DATE: \ h\ t DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE COW20I8 4/16/2018 6:31 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: WYNNE THE WINDSOR IM Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot# Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225 Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie . Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 - 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft' -_-_ 0 1 0 2SIab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft' _-_- 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft' _--- 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ft' 0 1 0 5 Slab -On -Grade Edge Insulatio LAUDRY 1 ft 0 36 ft' _--- 0 1 0 4/16/2018 6:31 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6'Slab-On-Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft' ____ 0 1 0 7 Slab -On -Grade Edge Insulatio DINING/GREAT 50 It 0 588 ft' ____ 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN lift 0 209 ft' ____ 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 ft 0 50 ft' ____ 0 1 0 10Slab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft' ____ 0 1 0 11Slab-On-Grade Edge Insulatio FOYER 9 it 0 92 ft' 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 it 0 169 ft' ___ 0 1 0 ROOF _ / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 1847 ft' 292 ft' Light 0.5 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61112 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft' 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft' 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 ft' 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 209 ft' 0.1 Wood 9 Under Attic (Vented) BATH. 30 Blown 50 ftz 0.1 Wood 10. Under Attic (Vented) HALL 30 Blown 25 ft' 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 92 ft- 0.1 Wood 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft' 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>W Exterior Concrete Block - Ext In3NMSTER BE 4.1 16 0 8 0 128.0 ft' 0 0 0.5 0 2 SW=>E Exterior Concrete Block - Ext InddASTER BE 4.1 7 0 8 0 56.0 ft' 0 0 0.5 0 3 NW=>S Exterior Concrete Block - Ext InddASTER BE 4.1 14 0 8 0 112.0 ft' 0 0 0.5 0 4 NE=>W Exterior Concrete Block - Ext InsMASTER BA 4.1 8 0 8 0 64.0 ft' 0 0 0.5 0 4/1612018 6:31 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 5 NE=>W Exterior Concrete Block - Ext InsuM. BATH 4.1 7 0 8 0 56.0 ft' 0 0 0.5 0 6 NE=>W Exterior Concrete Black - Ext InJIIEDROOM 2 4.1 12 0 8 0 96.0 ft' 0 0 0.5 0 7 SW=>E Exterior Concrete Block - Ext InQINING/GRE 4.1 30 0 8 0 240.0 ft' 0 0 0.5 0 8 NW=>S Exterior Concrete Block - Ext In9➢INING/GRE 4.1 20 0 8 0 160.0 ft' 0 0 0.6 0 9 SW=>E Exterior Concrete Block - Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft' 0 0 0.5 0 10 NE=>W Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.5 0 11 SE=>N Exterior Concrete Block - Ext Insul FOYER 4.1 8 0 8 0 64.0 ft' 0 0 0.5 0 12 SW=>E Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8 0 8.0 ft' 0 0 0.5 0 13 NE=>W Exterior Concrete Block - Ext InfiffDROOM 3 4.1 13 0 8 0 104.0 ft' 0 0 0.5 0 14 SW=>E Exterior Concrete Block - Ext InEEDROOM 3 4.1 1 0 8 0 8.0 ft' 0 0 0.5 0 15 N=>SW Garage Frame - Wood BEDROOM 3 11 26 8 208.0 ft' 0.23 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>N Insulated FOYER None .39 3 3 6 8 21.7 ft' WINDOWS Orientation shown is the entered orientation => chan ed to Worst Case. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>S 3 Metal Low-E Single Yes 0.63 0.25 N 32.4 ft' 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>W 5 Metal Low-E Single Yes 0.63 0.25 N 6.9 ft' 1 ft 0 in 1 ft 4 in None None 3 NE=>W 6 Metal Low-E Single Yes 0.63 0.25 N 16.2 ft' 1 ft 0 in 1 ft 4 in None None 4 SW=>E 7 Metal Low-E Single Yes 0.63 0.25 N 39.8 ft' 1 ft 0 in 1 ft 4 in None None 5 NW=>S 8 Metal Low-E Single Yes 0.65 0.21 N 40.0 ft' 8 ft 0 in 1 ft 4 in None None 6 NE=>W 13 Metal Low-E Single Yes 0.63 0.25 N 16.2 ft' 1 ft 0 in 1 It 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft' 806 ft' 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82 168.92 .2598 7 4/16/2018 6:31 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 HEATING SYSTEM System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Duds 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr dm 0.85 1 sys#1 HOT WATER SYSTEM #'. System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS _ / --- Supply — -- Return — Air CFM 25 CFM25 HVAC # V #: Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 250 ft' Attic 65 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablee Y Ceeiling Fans: Heat ng [X] an Jan EXl Feb Mar Apr Apr Mayr[[ ]] Jun Jul May r[[ ]] Aug [[ ]] [X] Sep [[[ ]]] [OctrX'] [NovrX'] HID Venting [[ ]] Jan [ I Feb X Mar [ LXl Jun [ Jul lXl I Aug LXl [[ ]] Sep lxl l^l Oct [X] Nov Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/16/2018 6:31 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with n any The insulation idropped ed ceiling /soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposededge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall becovered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawispace walls Shafts, penetrations Dud shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tubs The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids hPitveenfire.qn.r.inkler cover plates and wnlls or cailinas a. w euwuun, mspeutiun ui lug walls Snail be in ac nuance with the provisions o1 IGG-4uu. 4/16/2018 6:31 PM EnergyGaugeO USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) ' DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. THE WINDSOR, FT. PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Ext Insul, Exterior R=4.1 1224.00 ft2 b. Frame - Wood, Adjacent R=11.0 208.00 ft 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 3 d. N/A R= ft' 10. Ceiling Types Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1753.00 ft' 6. Conditioned floor area 1753 b. N/A R= ft, 7. Windows- Description Area c. N/A R= ft'z a. U-Factor: Sgl, U=0.63 111.36 ft' 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft 6 250 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft' SHGC: SHGC=0.21 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft' a. Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: N/A ft' 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.239 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ftx a. Electric EF: 0.97 b. N/A R= ft' c. NIA R= ft' b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant featur C> Builder Signature: Date: Address of New Homer kCli, , t�, Cl cS� City/FL Zip:�7 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/16/2018 6:31 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 -- wrightsoftm Project Summary Entire House QUICK CALCS, INC. For. WYNNE DEVELOPMENT THE Wt INDSOR; FFTT.. ,PIERCE, FL � Notes: � \a01�1 f 8CANNEr3 Job: lay Date: o Lucie COunth By: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD Summer Design Conditions 42 OF Outside db 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 18467 Btuh Central vent (0 cfm) 61 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heatingg. Coolingg. Area. (ftz) 1753 1753 Volume (ft') 14741 14741 Airchanges/hour 0.38 0.20 Equiv. AVF (cfm) 93 49 Heating Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Model 25HBC536A'030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow Airflow factor Static pressure Space thermostat. Capacity balance point = 34 OF 8.5 HSPF 34600 Btuh @ 470F 27 0 1160 cfm 0.047 cfm/Btuh 0.50 in H2O kW, Output = 23009 Btuh, 100 AFUE Calculations approved byACCA to meet 90 OF 75 OF 15 OF 50 % 61 gr/lb Sensible Cooling EquipmentLoad Sizing Structure 17655 Btuh Ducts 9340 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multipplier 0.95 Equipment sensible load 25645 Btuh Latent Cooling Equipment Load Sizing Structure 2453 Btuh Ducts 2554 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5007 Btuh Equipment total load 30652 Btuh Req. total capacity at 0.70 SHR 3.1 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A'030 Coil FX413N(B,F)037 AHRI'ref 791458 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual air flow 1160 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.84 Manual J 8th Ed. CP.WrIghESOft' RightSPage 1uite® Universal 2017 17.0.14 RBUD8101 2017-Apr-10 17:ge 1 ...k Caks\Documents%WYNNE-THE WINDSOR-REVISED.rup Cato = M,18 Front Door faces: N - wrightsoft' Right-M Worksheet Job: Entire House Date: ey. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 77246"796 Email: OUICKCALCS@AOL.COM 1 Room name Erdire House MASTER BEDROOM 2 3 Fgwed wall Room height 153.0 It 8.4 it d 45.0 It 8.0 ft heallcool 4 5 Room dimensions Room area 1753.0 it- 1.0 x 280.0 ft' 2810 ft' Ty Construction U-value Or HTM Area Load number I (Stuh1ftL*F) (BtulJftl or perimeter (ft) (Btuh) oorperimeter (ft) (Btuh) Heat Cool Gross MP/S Heat Cool Gross WP/S Heat Cod 6 13A-0acs 1Aclom 1Aclom 0.143 1.270 1.270 ne no -ne, 4.00 35.56 35.56 265 70.43 .70.43 488 7 16" 448 0 0 1795 247. 581 1141 488. . 1151- 192 0 0 192 0' 0 769 "0 0: 489 '0 .'0 - 11 :1Aclom 13A-4ocs - 1:270 0.143 ne, se 35.56 4.OD 45.24 255 • ' 18 64 0 41 581 165 739 105 " ,0 0 . 0 0 0 0 " .0 0 11D0 13A-0ccs' IAS2om 13AAM 1Aclom 4AS-2omd 12C-0sw - IBA SOmd 22A4pl 0.390 0.143--sw 0.770 0.143 1.270 o.770 0.091 0.032 0.989 se `sw. nw nw nw - - 10.92 4,00 21.56 4.00 35.56 21.58 2255 0.90 27.69 11.31 ... 255 - 27.53 2.55 45.2,4 36.90 - 1".28 2.32 . 0.00 23 "-..437'. 41 290 33 41 308 1753 - 1753 23 396 45 217 0 0 - 308 1753 153 248 1584 893 867 1162 880 784 1571 4237 257 1007 i 1140 551 1478 1505 395 4067 . 0 0 56 0 112 33 0 0 280 280 0 - 66 . o 79 0 0 . " 0 280 - 45 0 224 " - 0 318 1162 0 00 251 1246 0 - :143 - 0 202 1478 0 650 -. 0 �D yI _. P-: - C F 6 c)AED ex:ursion 1360 Epp Envelope loss/gain 16594 15385 3970 W61 12 a) infiltration b) Room ventilation 2873 0 810 0 809 0 0 22 0 0 13 Internal gains: Occupants Q 230 Appliances/other 2 460 1000 0 U Subtotal Qines 6 to 13) 1 18467 17655 4791 3789 14 15 Less wdemal load Less transfer Redistribution Subtotal Duct bads 34% 53% 0 0 0 18W 6190 0 0 p 176$5 9340 34% 53% 0 0 0 4602 1602 0 0 0 2005 2005 Total room load Air required(cfm) 2= 1160 26M 1160 6380 300 5794 249 .ti -F�- wrightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 ... k CalcslDocumentslWYNNE-THE WINDSOR-REVISED.mp Calc = MJ8 Front Door faces: 2017-Apr-10 17:19:28 Page 1 wrightsoft• Right-M Worksheet Job: Entire House °atei By: QUICK CALCS, INC. 317 ST. LUCIE LM, FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 7724664796 Email: OUICKCALCWOL.COM 1 Room name WIC M. BATH 2 Bilosed wall 0 It 7.0 it 3 Room height 8.0 ft heaticool 8.0 It heat1cool 4 Room dimensions 7.0 x 9.0 It 1.0 x 61.0 It 5 Room area 63.0 ft- 61.0 ft. Ty Construction U-value Or HTM Area W) Load Area (fN) Load number (BtuWft;°F) (BtuWft2) or perimeter (ft) (Btuh) or perimeter (8) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/5 Heat Cool 6 V11 ' 13AAocs 0.143 ne 4.00 2.55 0 0 0 0 56 49 196 125 1Acloo 1.270-.ne .3556 70.43 -0 0 0 0 7' "0. 247 488 `.1Actorn; '.. 1.270 ne.. ., 35.66 ,70.43, 0 0 0, 0 .0- 0 0.-. ,'0 '1Ac1om ,. - -1.270 -ne" 35.56 45.24 - 0, 0 : 0 - ' 0 0 '. -' 0. 0 �' 0 t1 Vd I-D 13AAccs 0.143 as 4.00 2.55 0 0 0 0 0 0 0 0 11D0 0.390 as 1092 11.31 0 0 0 0., 0 0 0 0 W : 113X4ws- - : ,.; 0.143 sw '.: ' 400 ...255 0 :.' 0 . -., 0 0 ,' ..0.. . 0: _. � .0 : :, 0 '�., 0 1 " ` '4A5-20rn ,.. .0.770 :.sw -' 1.56 27.53 0 0 0 '0 -0 :. .0 0 -0 V)1 13A4ocs 0.143 nw, 4.00 255 0 0 0 0 0 0 0 0 1Actom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 '.P. .; :12C-0sw ... 0.091 -- "2.55.-1:28. ...;0: ..0- 0 0.. _0 0':.:' '.q ... ",0 C 16A-30md 0.032 - 0.90 232 63 63 56 146 61 61 55 142 F- , 22A-tpl 0.989 •• 27.69 0.00 ' 63 0 0 . 0' , '61 -. 7 > - 194 : '0 6 c)AED a cumlon -5 -26 Envelope loss/gain 56 141 692 729 12 a) Infiltration 0 0 126 35 b) Rcomventilation 0 0 0 0 13 internal gains: Occupants (off 230 0 0 0 0 Applianceslother 0 0 Subtotal (lines 6 to 13) 56 141 817 . 764 Less etemalload 0 0. 0 0 Less transfer t 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 141 817 764 15 Duct loads 340/ 53% 19 75 34% 63% 274 404 Total room lead 75 216 1091 1168 Air required(cfm) 4 9 51 50 A&A -Ft+- wrilgi lSofY RlghtSuite® Universal 201717.0.14 RSU08101 ...k Calcs\DocumentslWYNNE•THEWINDSOR-REVISED.mp Calc=MJ8 Front Doorfaces: N 2017-Apr-10 17:19:28 Page 2 wrightsofY Right-M Worksheet Job: Entire House Date: sy. QUICK CALLS, INC. 317 ST. LUCIE Lin., FT. PIERCE, FL 34946 Phone: 772-4666799 Fax 772-466-6796 Emil: QUICKCALCS@AOL.COM 1 Room name LAUDRY BEDROOM 2 2 - Exposed wall 0 ft 12.0 ft 3 Room height 8.0 ft heat/cool 8.0 fl heat/cool 4 Room dimensions 6.0 x 6.0 ft 15.0 x 12.0 It 5 Room area 36.0 ft' 180.0 ft, Ty Construction U-,Adue Or HTM Area (fly Load Area (ft') Load number (Btuh/ft °F) (Stulff) or perimeter (ft) (Btuh) or perimeter (ft) i (Btuh) Heat Cool Gross WPIS Heat Cool Gross WP/S Heat Cool 6 V 13AAocs 0.143 ne 4.00 255 :0. 0 0 0 96 - 80 319 203 1Actorn .1.270 no .. `35.56 70.43' .. 0 0 . 0 .0 :. 0 .i.. , : 0. 0 - . 0 1Aa1om•,1 1.270 . no • -3556 70.43 : .0 • 0 0 "o 16'1 . 0 581 1161' tAcicm 1.270 . no 35.56 45.24 0 - 0 0 0 0 0. 0 . 0 11 Yt/ �---D 13AAms 0.143 se 4.00 2.55 0 0 0 0 0 0 0 - 0 11D0 0.390 as 1092 11.31 0 0 0 0 0 0 0 0 Vy � 13PAces - - 0.143 • sw - 4;00 - 2.55 0 0 - 0 0 - - 0 0 - .0 : 0 I-T'. 4AB-2dm ' 0.770 - sw 21.66 - 27.53 0 0 0 0 01 o . - . 0 . ..' 0 W 13A-4= 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 �G 1Aclom 1.270 nw 35.56 4524 0 0 0 0 0 0 0 0 4A5.2omd 0.770 nw 21.66 36.90 0 0 0 0 0 0 0 0 P 12C-0sw - 0.091 .- - Z55 .128 0 ,0 0 - 0.' 0 0 0 0 C 16A30md 0.032 - 0.90 Z32 36 36 32 84 180 180 161 418 F 22A-tpl . 0.989 , - . 27.69 ' 0.00 36 0 0 ' .0 180 .12 .' 332 • 0 6 c)AED excursion -3 -60 Envelope loss/gain 32 81 1394 1711 12 a) infiltration 0 0 216 61 b) Room vem8ation 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 32 81 1609 1772 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 6 14 14 Subtotal 38 95 1615 1786 15 Duct loads 34% 53% 13 50 34% 53% 541 945 Total room load 51 145 2156 2730 Air required (cfm) 2 6 101 117 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. G`h • wrightsoft- RIghlSuite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page 3 ... k Celcs\Documents\WYNNE-THEWINDSOR-REVISED.mp Calc=MJ8 Front Doorfaces: N I wrightsoft° Right-M) Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Faz 772-466.6796 Email: OUICKCALCSQAOL.COM 1 Room name DINING/GREAT ROOM 1117CHEN 2 F�osed wall 50.0 ft 11.0 ft 3 Rcom height 8.9 1t heat/cool 8.9 ft heat/cool 4 Room dimensions 1.0 x 588.0 ft 19.0 x 11.0 It 5 Room area 588.0 W 209.0 ft2 Ty Construction U-value Or HTM Area M Load Area (ft'j Load number (Stuhfft2-°F) (BtuWfl2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gmss I WP/S Heat Cool 6 1 13A4= - 0.143 no 4.00 265 0 0 0 0 0 0 0 0 1Acicim - - 1.270 no 35.56 70.43 0 0 0 0 0.. 0 0 0 - :1Acllom, 1.270 no 35.56 _." 70.43 0 0. 0. - 0 :. i 0 0 -0 -0 1Ac1cm 1.270 no 35.56 46.24 0- 0 0 0 0 0 0 t 0 11 W �D 13A-4= 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11DO 0390 se 10.92 11.31 0 0 0 0 0 0 0 0 Vy 13A4= 0.143 ' . sw 4.00 ',.:. 255 - 267 226 -903 " 674 98 ' . 98 - 392 -249 I--G 4A`Y2om - - 0.770 r sw ' 21.56 : 27.63 41 22 .893 : 1140 0 , 0 0 0 WI-- 13A4ws 0.143 nw 4.00 2.55 178 137 549 349 0 0 0 0 2 lA-clone 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 � 4AS-2omd 0.770 nw 21.56 36.90 41 0 880 1505 0 0 0 0 P. 12COsw1 0.091 -2.55 128 0 0 0 0 116 116 295 148 C 16A.30md 0.032 - 0.90 232 588 688 527 1364 209 209 187 485 'F' 122A-tpl 0.989 - 27.69 . 0.00 - 668 50 1365 : 0 209 11 305 + 0 6 c)AED mursion 1004 -64 Envelope loss/gain 5136 5937 .. 1179 818 12 a) Winration 1000 282 220 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 1000 Subtotal pines 6 to 13) 6136 6679 1399 1880 Less eMwel load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 0 0 14 Subtotal 6142 6693 1399 1880 15 Duct loads 34% 53% 2058 3541 34% 53% 469 995 ToW room load 8200 102M 1w 2875 Air required (ofm) 386 440 88 124 Ab-Z A wrightsoR- RlghtSulteO Universal 2017 17.0.14 RSUD8101 ...k CaloslDocumentslWVNNE-THE WINDSOR-REVISED.mp Calc = MJ8 Front Doorfaces: 2017-Apr.10 17:19:28 Page 4 wrightsoft° RighW@ Worksheet Job: Entire House Date: sy. QUICK CALCS, INC. 317 ST..LUCIE M. FT. PIERCE, FL 34946 Phone: 7724GM799 Fac 772-46"796 Email: OUICKCALCS@AOL.COM 1 Room name BATH HALL 2 1 wall 5.0 ft 0 It 3 Room height 8.0 It heat/cool 8.0 It Iheat/cool 4 Room dimensions 10.0 x 6.0 it 5.0 x 5.0 ft 5 Room area 50.0 W 25.0 ft2 TV nstiucticn U-value Or HTM Area (ft5 Load Area (ft2) Load number (Btutdit2-°F) (Btuwft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 Vh13AAocs 0.143 ne 4.00 255 40 40 160 102 0 0 0 0 '1Ac1om 1270 ne 35.56 , 70.43 0 0 0 .0 0 " o '.0 0 4Aciom-' 1270-ne; :.. 3556 70.43 '- 0 0 0.. 0. 0:. .,0, 01.. 0. °.lAciorn - -1.270 -ne 35.56 45.24 0 0 D 0 0- 0 0 0 11 W �-D 13A-4= 0.143 se 4.00 255 0 0 0 0 0 0 0 0 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 13A-0ocs:... ':..0.143 ,.. sw:- 4.00 ..255: .. 0 0 0 .0 .-`0.' 0= -, 0. �--, 0 I-G 4A5-2= 0.no sw 21.56 ; ' 27.63 0 o - 0 0 o .. -0 .-. o ' 0 13A4acs 0.143 nw 4.00 255 0 0 0 0 0 0 0 0 T� 1A�ctom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2omd 0.770 nw, 21.56 36.90 0 0 0 0 0 0 0 0 P: 12C-Osvi 0.091 - 255 -1.28 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 0.90 232 60 50 45 116 25 25 22 58 'F 22A-tPl 0.989 - 27.69 0.00 so 5 138 .. 0 - 25 0 0 - 0 6 c)AED excursion -8 -2 Envelope loss/gain 343 210 22 56 12 a) Infiltration 90 25 0 0 b) Rocmv2Mlation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Qines 6 to 13) 433 235 22 56 Less md" load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 -220 -% 14 subtotal 439 249 0 0 15 Duct loads 34% 53% 147 132 34% 53% 0 0 Total room load 586 381 0 0 Alr required(cfm) 28 16 0 0 �A - wrightsoft- RlghtSuite® Universal 2017 17.0.14 RSU08101 ...k CalcslDocumentslWYM,E-THE WINDSOR-REVISED.mp Calc = MJB Front Doorfaces: N 2017-Apr-10 17.19:28 Page 5 wrightsofV Right-M Worksheet Job: Entire House Date: ay: QUICK CALCS, INC. 317 ST. LUCIE LIA, FT. PIERCE, FL 34946 Phone: 77246b-6799 Fax 772466-6796 Email: OUICKCALCS AOL.COM 1 Room name FOYER BEDROOM 3 2 Exposed wall 9.0 ft 14.0 It 3 Room height 8.0 ft hewcool 8.0 it heaticod 4 Room dimensions 1.0 x 920 it 13.0 x 13.0 ft 5 Room area 920 W 169.0 ft' Ty Construction U-value Or HTM Area (ftj Load Area (tt') Load number (Btuh1ftMF) (Btuh/ft-) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heal I Cool Gross IN/PIS Heat Cool Gross WP/S Heat Cool 6 ' 13A4ccs 0.143 no 4.00 2.55 0 0 0 0 104 88 351 223 1Aclom 1.270 : "no 35.56 70.43 0 0 0 0 0 . 0 0 0 Wclorn 1:270 '. no. " 35.56 - 70.43 - 0 0 0 '0 0 : 0 0 . 0 `tAcicm , 1.270 no 35.56 45.24 0 0 0 s. 0 16 0 ,581 739 11 W 13A4= 0.143 se 4.00 2.55 64 41 165 105 0 0 0 0 �--D 11D0 0.390 se. 10.92 11.31 23 23 248 257 0 0 0 0 W -13A4cos' E-G �4A8-tam 0.143 _ sw 400 _ -: 255. 8' 8 32 20 8. - '8 32 - . - ,20 0.770'.sw 21.56 27.53 ` 0 0 0 0 0 :0 "0 - :0 W, 13A4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1Actom 1.270 nw 35.66 45.24 0 0 0 0 0 0 0 0 L� 4A5-2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 -P' 12C-0sw 0.091 Z55 1.28 .88 88 224 113 .104 . .104 265 133 C 16A-30md 0.032 - 0.90 232 92 92 82 213 169 169 151 392 F 22A-tpl 0.989 - 27.69 . 0.00 , 92 9 - 249 0, ` -169 14 388 0 6 c)AE1 excursion -25 S2 Envelope loss/gain 1002 684 1768 1456 12 a) Infiltration 162 46 252 71 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (Ilnes 6 to 13) 1163 730 2020 1527 Less eternal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1163 730 2020 15N 15 Duct loads 340A 53% 390 386 34% 53% 6T7 808 Total mom load 1 1553 1116 1 2697 2335 Air required(cfm) 73 48 IV 100 A&K -Ffd- wrights ft' Right -Suite® Universal 2017 17.0.14 RSU08101 ... k CalcslDocuments%WYNNE-THEWINDSOR-REVISED.mp Calc=MJ8 From Doorfaces: N 2017-Apr-10 17:19:28 Page 6 Duct System Summa Job: -�- wrightsoft� � Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 77246"799Fax 772466-6796 Email: OUICKCALCS@AOLCOM For. WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL External static pressure Pressurelosses Available static pressure Supply/ return available pressure Lowest friction rate Actual air flow Total effective length (fEL) Heating 0.50. in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm 183 ft Supply Branch Detail Table Name Design (Btuh) Htg (Cfm) Clg (cfm) Design FR Diam (In) H x W (n) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 586 28 16 0.372 4.0 OxO VIFx 19.5 115.6 st1 '•3, BEDROOM C 2730 101 117 0.384 7.0 Ox0 VIFx 15.0 115.0 stl ; BEDROOM 3 h 2697 127 100 0.353 6.0 Ox0 VIFx 26.8 115.0 st1'':`. DINING/GREAT ROOM C 3411 129 147 0.292 7.0 OxO VIFx 36.5 135.0 st2 DININGIGREAT ROOMS C 3411 129 147 0.371 7.0 Ox0 VIFx 19.9 115.0 Ell DININGIGREAT ROOM c 3411 129 147 0.278 7.0 Ox0 VIFx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 Ox0 VIFx 7.0 95.0 IaTC EN c 2875 88 124 0.366 6.0 0x0 VIFx 21.8 115.0 st1 LAUDRY C 145 2 6 0.371 4.0 OxO VIFx 19.9 115.0 st1 M. BATH h 1091 51 50 0.282 6.0 OxO VIFx 42.3 135.0 st2 MASTER BEDROOM h 3190 150 124 0.273 6.0 Ox0 VIFx 48.4 135.0 st2 MASTER BEDROOM -A h 3190 150 124 0.284 6.0 Ox0 VIFx - 40.9 135.0 st2 WIC I c 216 4 9 1 0.292 4.0 Ox0 VIFx 36.0 135.0 st2 Trunk Htg Clg Design I Veloc Diam H x W Duct Name Type (Cfm) (cfm) FR (fpm) (In) (In) Material Trunk st2 Peak AVF 612 602 0.273 780 12.0 0 x 0 VinlFlx st1 all Peak AVF 1087 1112 0,273 796 16.0 0 x 0 VinlFlx t Wfl htsOft' 2017-Apr-1017:19:29 ff 9 Right-SulteO Universal 2017 17.0.14 RSU08101 Page 1 k me ��...CalcslDocunlslWYNNE-THE WINDSOR-REVISED.rup CaIc=MJB Front Daor (aces: N Name Grille Size (in) Htg (cfm) Clg (cfm) TEL • (ft) Design FIR(fpm) Veloc IDiam (in) H x W pn) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 1 1160 1160 0 0 0 0 Ox O VIFx P. -Fp- wrightSoft Right -Suite® UIilmal201717.0.14 RSU08101 ... I Calcs\Docuwnts\WVMJE-TIE WINDSOR-REVISED.mp Calc = MJ8 Front Doorkces: 2017-Apr10 17.19:29 Page 2