HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERC/E , FL , \ q Owner: \ c% J � Permit Number: Jurisdiction: K `�"S Design Location: FL, Fart Pierce "-K''��.. ��`���---"' County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sqft.) Insulation Area 2. Single family p y or multiple family Single-family a. Concrete Block- Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types (1474.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1474.00 ft2 6. Conditioned floor area above grade (ft2) 1474 b. N/A R= ft2 c. N/Ducts A R= ft2 Conditioned floor area below grade (ft.)( 0 11 R 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 300 a. U-Factor: Sgl, U=0.63 101.25 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13 systems pAct kBt Efficiency d. U Factor: N/A ft2 a. Electriric Heat Pump �/r 34.8 HSPF:8.50 q'V/� SHGC:Area Weighted Average Depth: ft. `G�i �y �® Area Weighted Average SHGC: O 239 14. Hot water systems a. Electric C04 Cap: 40 gallons 8. Floor Types (1473.5 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 48.34 PASS Total Baseline Loads: 48.53 1 hereby certify that the plans and specifications covered by Review of the plans and 4Zt18 Srgr this calculation are in compliance with the Florida Energy specifications covered by this �� __ g 001 Code. calculation indicates compliance yai a„.4po"r'�_ '0 with the Florida Energy Code. un,:R'4, ', ;,.•` „ O PREPA Y: DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 C 0 1 a I hereby certify that this building, as designed, is in compliance Florida Statutes. J,l, with the Florida Energy Code. COD WE S¢v OWNER/AF`NT' BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). I L EEC 2 6 0, PY 4/17/2018 12:27 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: WYNNE THE STERLING Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE STERLING Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 329 ft- ---- 0 1 0 2SIab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft' ---- 0 1 0 3SIab-On-Grade Edge Insulatio M. BATH 8 ft 0 56 ft' ---- 0 1 0 4SIab-On-Grade Edge Insulatio KITCHEN 1 ft 0 192 ft' --__ 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' ---- 0 1 0 6 lab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft' ---- 0 1 0 7 lab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft' _--- 0 1 0 4/17/2018 1 27 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY Eft 0 42 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 ---- 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1553 ft2 246 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1474 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 329 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 NE=>SW Exterior Concrete Block - Ext InS®EDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 2 SW=>NE Exterior Concrete Block - Ext Ins®EDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext Ins®EDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 5 'NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 _ 6 NE=>SW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 7 SE=>NW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 8 S=>N Exterior Concrete Block - Ext InfiffDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.6 0 9 SW=>NE Exterior Concrete Block- Ext InGEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 _ 10 SE=>NW Exterior Concrete Black - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 11 SW= NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 _ 12 SW=>NE Exterior Concrete Block - Ext InsdLAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 13 NE=>SW Exterior Concrete Block - Ext In9 REAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.6 0 _14 NW= BE Exterior Concrete Block -Ext InaGREAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.6 0 15 NJ S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.6 0 4/17/2018 12:27 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW 13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 0.63 0.25 N 32.9 ft' 1 ft 0 in 1 ft 4 in 0.63 0.25 N 6.9 ft' 1 ft 0 in 1 ft 4 in 0.63 0.25 N 24.0 ft' 6 ft 0 in 1 ft 4 in 0.63 0.25 N 37.5 ft' 1 ft 0 in 1 ft 4 in 0.65 0.21 N 40.0 ft' 8 ft 0 in 1 ft 4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft' 24 it 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgI-A ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1375.7 75.53 142.04 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' 4/17/2018 12 27 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 DUCTS — Supply — -- Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 300 ft° Attic 75 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programabl[e Ceiling Fans: ]Thermosta[[t:]]Y [ ] May[[ ]] [[ ]] [ ] [ ] [[ ]j Heating [X] JDec an [X] Feb Mar [ ] Apr[ ]May [X] Jun [X] Jul Aug Sep LJ Oct [Oct[X�] Nov [NovrX'j Venting [[ ]] Jan [[ ]] Feb X Mar [X] [ ] [[ 11 Jun [[ ]] Jul EX] ] Aug EX] 1 Sep ll�xll [X] [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4117/2018 J27 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electricallphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids be.tweenfire qp.r.inkler cover plates and walls or cellino.% a. m auuumn,i mspecuon of log watts snau be In accoraance with the provisions of IGO-400. 4/17/2018 12i27 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. THE STERLING, FT. PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ftz b. Frame - Wood, Adjacent R=11.0 192.00 ft 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d. N/A R= ft' 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 1474.00 ft= 6. Conditioned floor area (W) 1474 b. NIA R= ft' 7. Windows'* Description Area c. NIA R= ft' a. U-Factor: Sgl, U=0.63 101.25 ft' 11. Duds a. Sup:. Attic, Ret: Attic, AH: Attic R ft' 6 300 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft' SHGC: SHGC=0.21 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft' a. Central Unit 34.8 SEER:15.00 SHGC: d. r: NIA SHGC: SHGC: 13. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average Overhang Depth: 3.832 k. Area Weighted Average SHGC: 0.239 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft a. Electric EF: 0.97 b. N/A R= ft' c. N/A R= ft' b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. C� Builder Signature: Date: Address of New Home: ��� City/FL ZiP7' L' --,, *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/17/2018 12:27 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 - wrightsoft� Projed-Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LN:, FT. PIERCE, FL 34946 Phone: 772-468-8799 Fm 772-4E For. WYNNE DEVELOPMENT THE CARLTON 299, FTT. PIERCE, Fcl- Notes: \ \,A v �J Design Information Weather. Winter Design Conditions Outside db 42 OF Inside db 70. OF . Design TD 26 OF Heating Summary Structure 18188 Btuh Ducts 5654 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 23842 Btuh Infiltration Method Construction quality Fireplaces Fort Pierce, FL, US Simplified Average He iw Co lln Area ft? 14 Volume (ftj 12227 12227 Air changeslhour 0.45 0.23 Equiv.AVF (cfm) 92 47 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A"030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow Air, flow factor Static pressure Space thermostat Capacity balance point = 33 OF Backup: 8.5 HSPF 34600 Btuh @ 47OF 27 0 1160 cfm 0.049 cfm/Btuh 0.50 in H2O Input = 7 kW, Output = 23009 Btuh, 100 AFUE Job: Date: By: cSf�4ce�N F® I Cp44 Summer Design Conditions Outside db 90' OF Inside db 75 OF Design TO 15 OF Daily range L Relative humidity 50 % Moisture difference 61, gr/lb Sensible. Cooling Equipment Load Sizing Structure 17877 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0. Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 25093 Btuh Latent Cooling Equipment Load Sizing Structure 2958 Btuh Ducts 2319 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5277 Btuh Equipment total load 30370' Btuh Req. total capacity at 0.70 SHR 3.0 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A•030 Coil FX4DN((B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual airflow 1160 cfm Air flow factor 0.044 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft' 2017-Apr-1017:14:53 ,ram; RlghtSuite® Universal 2017 17.0.14 RSU08101 Page 1 -...I dghtsoft HVAC\WYNNE-THE GRAND CARLTON-299.mp Calc=MJ8 Front Door faces: N I# wrightsoft Right-M Worksheet Job: 87dre House Date: ey: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House BEDROOM 2 Exposed wall 156.2 It 52.0 It 3 Room height 8.3 It d 8.0 It heat/cool 4 Room dimensions 1.0 x 329.0 It 5 Room area 1473.5 ft2 329.0 ft' Ty Constmction number U-value (Btuh`fti°F) Or HTM (Btu(yft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load I (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 W = 13AAMs ".0.143 ne - - 4.00 - 2.55 '479 - 442 - 1768 : 1124 , 80 : 80 320 �.,, 204 Imo. n 9Atc1onn -• 1.270 -0.143 . ne_ 35:56 ..I0.43:. 38 , 0 ..., . ,1344 .- .:2662 -0' :0 .0 ' ., - 0 W, 13ocs se 4.00 2.55 128 83 331 210 0 0 0 0 �LGDP,-1 1Ac1cm 1.270 se 35.56 34.77 24 48 848 829 0 0 0 0 11 11DO 0.390 se 10.92 11.31 22 22 - 236 244 0 0 0 0 W -' V�/ I--G 13A-0dcs 13A-4= 0.143 0.143 ,s sw 4:00. 4.OD 255 2.55 - 34 360 .34 353 '. - 136. 1414- •86 899 0 224 . 0 224 0 897 `0 670 1Ac1cm 1.270 sw 35.56 42.91 7 11 247 298 0 0 0 0 13A4ws 1Actom ,: :0143 4270 rnv., �nw' . ' 4.00 3556 ' 2.55 e 45.24 290 33 : 217 - 0 - . 867 .. 1162 . . 551 • 1478 112 - 33 - :79 :; . ' '0, ' 318 1162 202 r1478 05-2am- a0770'nw : 2156 .-,: 27.54 41 0 880. 1124 0' 0 0 •'.r0 P 12C-Osw 0.091 - 2.55 1.28 192 192 489 246 0 0 0 0 C .18A-30md 0.032 - 0.90 2.32 -. 1474 1474 1320 . . 3419 329 - ' 329 295 - 763 F 22AApl 0.999 27.69 0.00 1474 156 4325 0 329 52 1440 0 6 c)AED=urslon 784 680 Envelope loss/gain 15366 13954 4432 3897 12 a) Infiltration 2822 773 909 249 b) Room ventilation 0 0 0 0 13 Wemal gains: Occupants @ 230 5 1150 2 460 Appliances/other 20DO 0 Subtotal (lines 6 to 13) 18188 17877 5341 4606 14 15 Less leMemal.load 'transfer Redistribution Subtotal Duct loads 31% 48% 0 0 0 18188 5654 0 0 0 17877 85M 31% 48% 0 0 0 5341 1660 0 0Less 0 4606 2199 Totalroom load Air required (c(m) 23842 1160 26413 1160 7001 341 6805 299 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Fk- wrightsoft- Right -Suite® Universal 201717.0.74 RSU06101 2017-Apr-10 17:14:53 . A ...Wrightsoft HVACIWYNNE-THE GRAND CARLTON-299.rup Calc=MJS Front Door faces: N Page 1 + wrightsoftRight-M Worksheet Job: Entire House Date: ey: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM 1 Room name WIC .. M. BATH 2 Elposed wall 0 it 8.0 ft 3 Room height 8.0 It heaVcool 8.0 It hea0c001 4 Room dimensions 7.0 x 9.0 It 7.0 x 8.0 ft 5 Room area 63.0 ft' 56.0 ft. TY Construction U-value Or HTM Area (ft� Load Area (fit-) Load number (StuWftuF) (Btuwft') or _ perimeter (ft) (Stuh). or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Grass N/P/S Heat Cool 6 - 13A-0acs 4. `0.143 -,no 4.00 :- 2.55 0 �0 ' 0. '0 :0 0 0 �i0 I-G dAclom. ,: ,.:1.270 fie "...3556: .70.43. :0'. .0 ..' 0.. .'.,0 .....0: ,, ., ,O r - 0 i.=;0 �1 13A-4= 0.143 ` se 4.00 2.65 0 0 0 0 0 0 0 0 �C 1Aclom 1.270 se 35.56 34.77 0 0 0 0 0 0 0 0 11 I-D 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W,:.., 13AAoce:... -.. s 0.143 sr..: - 4.00 -.. 2.55 - 0 -0 0 . .. 0 0 :.. 0 •:20 ... , ­0 ,. .-° 0 t-G 13A4ocs 0.143 sw 4.OD 255 0 0 0 64 57 228 145 1Aclom 1270 sw 3556 42.91 0 0 0 0 7 5 247 298 ' . 13A+bcs -,0143 my 4.00 2:55 0 0 -. 0 0 .0 . 0 '... 0 :.,`' 0 =.. 1A-clortl ,:1270 Kw .' .W 45:24 " .0 , 0 - 0 0 0 1 0 0 '. -0 4A&2arr," -+ono - nw ;21.56 �27:54 0-: 0 ` - 0 .0 0'i 0.` .0 0 P 12C-03w 0.091 - 2.55 1.28 0 0 0 0, 0 0 0 0 C 16A-30md 0.032' - 0.90 .232 63 63 56 146 56 56 50' 130 F 224tpl 0.989 - 27.69 0.00 63 0 0 0 56 a 222 0 6 c)AED excursion -2 .2.25 Envelope lass/gain 56 145 747 798 12 a) Infiltration 0 0 140 38 b) Room ventilation 0 0 0 0 13 Intenial gains: Occupants @ 230 0 0 0 1 Appliances/other 0 0 Subtotal oines 6 to 13) 56 145887 836 Less �extemal load 0 00 0 Less itransfer 0 00 T/48% 0 Rediiltdbution 0 00 0 14 Subtotal 56 145897 836 15 Ductloads 31% 48% 18 69 276 399 Total lroom load 74 2141162 1235 Air raquired(cfm) 4 967 54 ,4g& F- wrightsofe- RlghtSuite® Universal 201717.0.14 RSUD8101 ...Wrighlsoft HVAMWYNNE-THE GRAND CARLTON299.mp Calc=MJB FrontDoortaces: 2017-Apr.10 17:14:53 Page 2 wrightsoft' RighW@ Worksheet Job: Entire House Date: ey: QUICK CALCS, INC. 317 ST.. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name KrrCHEN BATH 2 3 E�dsed wall Room height 0 If 8.0 It hwt/cool 5.0 If 8.0 If hea0cool 4 5 Room dimensions Room area 1.0 x 192.0 It 192.0 ft- 9.0 x 5.0 R 45.0 ft- Ty Construction U-v41ue Or HTM Area (fe) Load Area (ft2) Load number (BtulVftmF) (Btuwft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 IN -1--�. 13A4ccs 0.143 ne 4.00 '-. 2.55 0 0 0. 0 . 40 - `40 160 ",102 JAclw, ".1.270 ne. f 35.56 ... 70.43 .. 0; .0. '. ,.01 0: .' 0 0 .0 ,.-. . 0 13A fccs 0.143 as 4.00 2.65 0 0 0 0 0 0- 0 0 11 I-D 1Actom 11DO 1.270 - 0.39D se se 35.56 10.92 34.77 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W -., 111 IaAAws, 13A4ocs 0:143: 0.143 ;s sw r-.4.00 4.00 2,55' 255 0 0 0 0 ..0, 0 0. 0 0; 0 0 0 0 0 0 0 Y-G 1Ac1wn 1270 sw 3556 42,91 0 0 0 0 0 0 0 0 Vy IL----.GG 13AAocs- 1Ac1om" ' -.0143,nw.., - 1 270 rl 400 35.56 266 ` 45:24 0' -.0 0 0 0 :. 0 0 - 0 0' 0 0 - . 0 0. 0 `0 4A5-20n DT70 nw'. , 21.56 27.54 0 . 0 0 ... 0 0 .0 0 -0 - ,:, '0 P 12C-0sw 0.091 - 2.55 1.28 64 64 163 82 0 0 0 0 C 16A-30md 0.032 °- 0.90 2.32. 192 192 172 445 - 45 45 40 104 F 22A-tpl y. 0.989 - 27.69 0.00 192 0 0 0 45 5 138 0 6 c)AED mursion _27 -2 Envelope loss/gain 335 601 339 204 12 a) Infiltration 0 0 87 24 b) Room ventilation 0 0 0 0 13 Internal gars: Occupants @ 230 Applianceslother 0 0 20M 0 0 0 Subtotal pines 6 to 13) 335 2501 426 226 14 15 Laoslextema load Less transfer Redistribution Subtotal Ductiloads 31% 48% 0 0 0 335 104 0 0 0 2501 1194 31% 48% 0 0 0 426 133 0 0 D 228 109 Total;.. load Air required (cfm) 439 21 3695 162 558 27 336 TEl wrightsoft- RlghtSuite® Universal 2017 17.0.14 RSU08101 2017-Apr-1017:14:53 ..,Wdghtsoft WAC\WYNNE-THE GRAND CARLTON-299.rup Colo = MJ8 Front Door faces: N Page 3 wrightsoft Right-J® Worksheet Job: Entire House Date: sy: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS AOL.COM 1 Room name BEDROOM 2 ENTRY 2 5¢ased wall 32.2 ft 7.0 it 3 Room height 8.0 If heaUcool 8.0 If heat/cool 4 Room dimensions 1.0. x 203.5 ft 1.0 x 55.0 ft 5 Room area 203.5 ft- 55.0 ft- Ty Construction U-value Or HTM Ares (III Load Area (ft' Load number (Btuh/f(MF) (9tuWft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool e VN .A3A-0dcs , 0.143 .no , 4.00 , , 2.65 ' 128 - 128 513 326 0' 0 , 0 ' ,.0 L_-C: 7Ac1om't - 1.270 fie 35.56 , 0" 0 .,. 0' ,, 0 0'. 0 .. 0 , .. =0 13AAms 0.143 as 4.00 .70.43 255 80 56 225 143 48 26 106 67 IAclom 1.270 se 35.56 34.77 24 24 848 829 0 0 0 0 11 11D0 0.390 as 10.92 11.31 0 0 0 0 22 22 236 244 :W . :13AAocs - 0:143' 's 4:00 -2.55 34. 34 .. 136 . :56 0 0 0: • ,..0 Yy 13A-4ocs 0.143 sw 4.00 2.55 16 16 64 41 8 8 32 20 1Aciom 1.270 sw 35.56 42.91 0 0 0 0 0 0 0 0 -a 13A-0acs 0.143 my "400 . -255 0; .0 0 .0' 0'. ", 0,.-' 0 '0 >1Aciom 1.270 nw. 35.56 45.24 .0 •' "0 0. ' • .0 0:. `. " 0 0 ;'o ' :4A5-2om 0.770 nw 21.56 27.54 0 0 � . 0 0 0 0 . 0 0 P 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 72 72 183 92 C' 16A30md 0.032 - 0.90 2.32 204 204 182 - 472 65 55 49 128 F 22A.tpl 0.989 - 27.69 0.00 204 32 891 0 65 7 194 0 6 c)AED excursion -24 -6 Emelope lomfgain 2899 1873 800 545 12 a) Infiltration 564 154 122 34 b) Roomventiladon 0 0 0 0 13 Internet gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal(Iines 6to 13) 3422 2257 922 579 Less pdemal load Less ti lnsfer 0 0 0 0 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3422 2257 922 579 15 Duct loads 1 31% 48%1 1064 1078 31% 480/6 287 276 Total room Iced I 1 1 4486 3335 1209 855 Air required (cfm) 218 146 59 38 ,.1. Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A& T� wrlghtsoft- Rlght-Suite@ Universal 201717.0.14 RSU08101 2017-Apr-10 17:14:53 ...Wdghtsoft HVAC\WYNNE-THE GRAND CARLTON-299.mp Colo = MJB Front Door faces: N Page 4 +� wrightsoft" Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-4666799 Fax 772-466-6796 Emil: OUICKCALCS@AOL.COM 1 2 3 4 5 Room name Egmed wall Room height Room dimensions Room area LAUNDRY 6.0 it 8.0 ft heaVcool 7.0 x 6.0 ft 42.0 ft' GREAT/DINING 46.0 ft 8.9 ft heat/cool 1.0 x 488.0 ft 488.0 fin Ty Construction number U-value (BtuIVfP;*F) Or HTM PUMP) Area (fe) or perimeter (ft) Load (Btuh) Area (M or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 1M ^- ,13A-0acs 1Aatorn 13A-0acs .. - 0.143 1.270 0.143 ' ne- ne' as " 4.56 35.56 4.00 7 2.43 ,. 70.43 2.55 . '.0' . 0 0 0 0 0 .., 0 0 0 - 0 0 0 231 ., 38', 0 ' 194 . p 0 775 . ".• 1344 0 ..,:. 493 .. ,, 2662 0 IN�C 11 1A-o1om 11DO ..13A,4ocs.... 13AAws 1A-ctom 13A-0ocs' • 9Ac1om+' 1.270 0.390 0.143 0.143 1.270 0.143 L1.270 se as -s sw sw nw. nw 35.66 10.92 4:OD 4.00 35.56 4.00 _: 35.56 34.77 11.31 ,; 2.65 2.55 42.91 255 = 45.24 0 0 '0 48 0 - 0 0 0 0 0.,,. 48 0 0. 0 0 0 0 192 0 .01 .: 0 0 0 :. 0 122 0 0 •' . 0' 0 0 - 0;' 0 0 ' 178 0 0 0 - 0 0 0 ; 137'. x . .0 0 0 :0 0 0 ' 649 0 0 0 , ,0 0 0 349 ; '- 0 W" W L-G 4A5-20m' -0.770 rlw r 21.56 27.54 0 0 0 0 41 - 0 880 "1124' P 1213-0sw 0.091 - 2.55 1.28 56 56 143 72 0 0 0 0 C ;16A-30md 0.032. - 0.90 2.32 42 - 42 38 97 488 488 437 1132 F 22A-tol 0.989 - 27.69 0.00 42 6 166 0 488 46 1274 0 6 c)AED excursion S -56 Envelope loss/gain 539 288 U59 5704 12 a) infiltration 105 29 896 245 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 644 317 6154 6409 Less eldemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 644 317 6154 6409 15 Dud loads 31% 48% 200 151 31% 48% 1913 3060 Total room load Air required (cfm) 844 41 468 21 8067 393 9469 416 wrightsoft- 2017-Apr-1017:14:53 ,&A Right-3uiteO Universal 2017 17.0.14 RSU08101, Page 5 ...Wrighlsoft WAC\WYNNE-THE GRAND CARLTON.299.mp Calo=MJB Front Doorfaces: N +�- wrightsofte Duct System Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-46"799 Fes 772-466.6795 Emil: QUICKCALCS@AOL.COM For: WYNNE DEVELOPMENT THE CARLTON 299, FT. PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply/ return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 Cfm Job: Date: By: Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 cfm 176 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Cig (cfm) Design FIR Diam pn) H x W (in) Duct Mail Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 559 27 15 0.376 4.0 OxO VIFx 18.1 115.0 st1 BEDROOM 2 h 4486 218 146 0.374 6.0 OxO VIFx 18.6 115.0 st1 BEDROOM -A h 3501 170 149 0.297 6.0 OxO VIFx 33.1 135.0 st2 BEDROOM-B h 3501 170 149 0.284 6.0 OxO VIFx 41.1 135.0 st2 ENTRY It 1209 59 38 0.510 4.0 OxO VIFx 3.0 95.0 GREAT/DINING c 4735 196 208 0.318 7.0 OxO VIFx 22.4 135.0 st2 GREAT/DINING-B c 4735 196 208 0.307 7.0 OxO VIFx 28.1 135.0 st2 KITCHEN c 3695 21 162 0.375 7.0 0x0 VIFx 18.3 115.0 st1 LAUNDRY h 844 41 21 0.366 6.0 0x0 VIFx 21.6 115.0 st1 M{,BAT7 h 1162 57 54 0.366 4.0 Ox0 VIFx 21.6 115.0 st1 WIG c 214 4 9 0.310 4.0 0x0 VIFx 26.3 135.0 st2 Supply Trunk Detail Table Trunk Htg Cig Design Veloc Diann H x W Duct Name Type (cfm) (Cfm) FIR (fpm) (In) (In) Material Trunk st2 Peak AVF 737 724 0.284 689 14.0 0 x 0 VinlFlx Bill st1 Peak AVF 1101 1199 0.284 804 16.0 0 x 0 VinIFIx Wrl htsoft` 20n-Apr-1017:14:54 I'mg Right -Suite® Universa12017 77.0.74 RSU08707 ...Wilghtsoft HVAC\WYNNE-THE GRAND CARLTON-299.rupOnto =MJS Front Door faces: N Page 1 Name Grille Size (in) Htg (cfm) CIg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mall Trunk rbl OxO 1 1160 1160' 0 1 0 0 0 Ox 0 1 VIR, i htsoft° 2017-Apr-1017:14:54 wr 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 ...WrightsoO WACIWYNNE-THE GRAND CARLTON-M.rup Calc=MJ8 Front Door faces: N