Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
/,gl2 - O3 FORM R405-2017 FILE COPY FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method -SU Project Name: CALIANDRO 3 MODEL Builder Name: RAVE GOLDEN HOMES MVE® Street: 18102 BRIDLE WAY Permit Office: ST LUCIE COUNTY City; State, Zip: FORT PIERCE, FL, Permit Number. m�aaBy St. Lucie Owner. Jurisdiction: ST LUCIE COUNTY Count Design Location: FL, Fort Pierce County: St Lucie (FloddaClimate Zone. 2 ) 1. New construction or existing, New(From Plans).. 9. Wall Types (2106.0 spit) Insulation. Area 2. Single family or multiple family Single-family a. Concrete Block- Ext Insul, Exterior R=4.1 1835.30 fP b. Frame Adjacent R=11.0 270.671? 3. Number of units, if multiple family 1 Ame-Wood, R= W 4. Number of Bedrooms 3 d. WA R= ft- G. Is thisa worst case? No 10.Ceillng Types (2764.0 sgfq) ,Insulation Area a. Roof Deck (Unvented) R=20.0 2764.00 ft- 6. Conditioned floor area above grade (ft') 2764 b. N/A R= It - Conditioned floor area below grade (ft-) 0 c. N/A R= fN 11. Ducts R ft' 7. Windows(362.0 sgf4) Description Area. a. Sup: Attic, Ret: Adic, AH: Garage 6 200 a. U-Factor: Sgl, U=0.65 200:00 ft- SHGC: SHGC=0.30 b. U-Factor. Sgl, U=0.65 162.00 ft' 12. Coding systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 46.5 SEER:16.00 c U-Factor: WA ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. WA ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted: Average Overhang Depth: 1.333 ft. Area Weighted. Average SHGC: 0.278. 14, Hot water systems 8. Floor Types (2764.0 sgft:) Insulation Area a. Electric. Cap: 50 gallons a. Sian -On -Grade Edge Insulation R=0.0 2764.00'ft' b. Conservation features EF: 0.980 b. N/A R= IF None c. N/A R= ft2 16, Credits None Glass/FloorArea: 0.131 Total Proposed Modified Loads: 80.84 P/'"t.QS Total Baseline Loads: 83.39 I hereby certify that the plans and specifications covered' by Review of the plans and 57�� this calculationare in compliance with the Florida Energy specifications covered by this oFSXfi Code. 3. calculation indicates compliance 'R' with the Florida Energy i unu :. •. Y PREPA E • 09 Before construction is completed DATE: - this building will be inspected for compliance with Section 553.908 0 '" 1(01� > I hereby certify that this bulidi , as de 'gned, is in compliance Florida Statutes. with the Florida Energy Cod . CODwe OWNER/AGENT, BUILDING OFFICIAL: DATE: Ll DATE: - Compliance requires certification by the: air handier unit manufacturer that the air handler enclosure qualifies as certified; factory -sealed in accordance with 11403.3.2.1. • Compliance.requires an Air Barrier and Insulation Inspection Checklist In accordance with. R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 1I82019 9:48.AM EnergyGaugel& USA Section R405.4.1 Compliant Software Page 1 of 6 CnRnd RdnA.9n17 IMPHT,SUMMARY CHECKLIST REPORT PROJECT' TWT. CALIANORO 3-MODEL Bedrooms: 3 Address Type:, Strcet:Address' Budding Type: User. `Conditioned Area: 2764 .Lot # Owner Name: Total Stories:, 1. BlooklSuMfivislon: #of Units; 1,- • Worst`Case;- No. Platsocki. - BuilderName: DAVE GOLOENAOMES RotateAngle: •0 Street, -18102BRIBLEWAY Permit Office: ST'LUCIE'COUNTY CrossVenhlation: No County. St. Lucie ., Jurisdiction:. ST LUCIE COUNTY `,1"clo House Fan: No" City, State; Zip, FORT: PIERCE, . FamllyType: Singlatamlly FIL `,New1Exls6ng: Ne_''(Fnxm Plans) Comment - CLIMATE Design Temp ,Int Design Temp Heating Design- Daily Temp Design.Location TMY Site 97.5 % 2.6 % Winter Summer Degree Days, Moisture Range FI,.FortrtPierce ',FL_VERO BEACM_MUNI 39 90 70 75, 299 62 Low s1.ocKs Number Name Area Volume 1 Entire House ':2764 26453.8 ' SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID: Finished Cooled Heated 1 MASTER BEDROO „265 2397 No 0. 1 1 Yes' yes, Yes 2 MBATH 172 1616.8 No 0 1 Yes. - Yes Yes • Z3- MTOILET 20. '188: No 0 : 1.,, No Yes. Yes • 4 GREAT ROOM 571 57-10 No 0' 1 Yes • Yes Yes 5 M W IC 99 '930.6 . No 0 1 No Yes. Yes 6 BATH 1 55 517 No '0 1 Yes Yes Yes 7 WIC 1 44 413.E No 0 1 Yes „Yes, Yes 8 BEDR60M 1 245 2303' No a 1 1 Yes - Yes Yes :9 BEDROOM 2 190 1786 No 0 1 7, Yes Yes Yes 10 CLST2. 20 188 :No 0' 1. 'No. yes Yes . 11 HALLWAY - 139 1306.6 No 0 1' No Yes Yes .42 BATH2 67 629.:8 ,No 0 1, ' No.. . Yes. Yes 13 OFFICE CLST 10 94 No A 1 - No Yes, Yes 14 OFFICE 172 1616.8 No 0 '1 'Yes Yes 'Yes 15 FOYER 216 2160 No 0 1 -Yes Yes Yes 16 KITCHEN:' 278 '2613:2 Yes 0 1 Yes ,• Yes. Yes 17 LAUNDRY 126 1184.4 No '0 1 Yes. Yes Yes 18 HALL 45. 423 ` No 0 - V yes:. Yes. Yes ' 19 LINEN- 16 150.4 No 0 1 No Yes Yes 20 PANTRY 24 ,225.6No, 0 No 'Yes . Yes 1180019 9A8 AM EnergyCaugeO USA Section R405.4.1 Compliant Software. Paget of 6 ;FORtuI R40&21)17 INPUT SUMMARY. CHECKLIST REPORT FLOORS- ' .#.. Floor Type Space :Perimeter Perimeter R-Value .Area Joist RValue: Tlle�' Wood. Carpet 1 Slab -On -Grade Edgeinsulaion MASTER BEDR0 .32 ft 0 255.fF ___- 1 0 0 2 Slab -On -Glade Edge. Insulation M.BATH let 0 172W 1 :0 ' 0 3Slab-On-Grade Edge Insulation MTOILET 1dt 0 20 ft' -- 1 0 0 4 Slab -On -Grade Edge Insulation GREAT ROOM 29 ft 0 571 ft' — 1 0 0 5 SIab-On-Grade Edge Insulation MWIC t.ft. -0 99 ff? __ 1 0 0 6 Stab-On=Grade'Edge Insulation BATH 5ft- 0 55 ft- ___ 1 0 0 7 Slab -On -Grade Edge insulation WIC 4ft 0 44 IF __— 1 0 0 8 Slab -On -Grade Edge, insulation BEDROOM.I 32 ft 0 245 ft- ____ 1 0 �0 '9 Slab -On -Grade Edge Insulation BEDROOM 2 21 ft 0 190 ft' 1 0 0 10SIab-On-Grade. Edge Insulation CLST 2 1 ft, 0 20 ft' __ 1 0 0 I lSlab-On-Grade:Edge Insulation HALLWAY 1 ft. 0 139 W ,_�. 7 0, 0 12SIab-On-Grade Edge Insulation BATH 2 i ft 0. 67 ft- 1 •0 0 73Slab-On-Grade, Edge Insulation OFFICE CLST 'oft 0. 10f- _-- 1 0 0 `;. 14SIab-On-Grade Edge:, Insulation OFFICE Sit 0: 172 ft' __ 1 0 0 i0ab-On-Grade Edge Insulation FOYER '6ft 0 216 fV 1 0 0 leslab-On-Grade Edge lnsulallon KITCHEN l4ftr 0 278 H'- ____ 1 0 0. 17SIab-On-Grade Edge lnsulabon- LAUNDRY 23ft 0 126ft' _— 1. 0. 0 18SIab-On-Grade Edgainsulation HALL 5ft 0 45 ft' _ 1 0 0 1931ab-Or Gfade Edge Insulation. LINEN 1ft 0 16 fN 1 0 0 ' 20SIab-On-Grade Edge Insulation PANTRY i,ft 0 24 ft' ____ 1 0 0 ROOF .._. , _ Roof Gable Roof Bclar SA Enid 'Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested.. Insul. (deg) 1 Hip. Metal 3D91 ft' 'b ft- Medium 0.6 No 0.9 No 20 26.6 ATTIC J# Type Ventilation Vent Ratio (I in) Area RBS IRCC 1 Full attic Unvented 0 2764 fF N N 118/2019 9:48 AM EnergyGaugelD USA SectionR405.4.1 Compliant Software Page 3,of 6. FORM.R405-'2011 INPUT SUMMARY CHECKLIST REPORT CEILING ff Ceiling Type Space R;Value Ins Type Area Framing Free- Truss Type 1 Under Attic (Unnamed) MASTER BEDRO 20 Blown 265 ft' 0.1 Wood 2 Under Attic (Unvenled) M.BATH 20, Blown 172R' 0.1 Wood _ 3 Under Attic (Unvented) M TOILET 20 Blom 20 W 0.1 Wood _ 4 Under Attic (Unvented) GREAT ROOM 20 Blown 671 W 0.1 Wood. _ 5 Under Attic (Unvented) MWIC 20. Blown 99 N' 0.1 Wood _. 6 Under.Attic (Unvented) BATH 1 20 Blown 55 ft' 0.1 Wood 7 Under Attic Unvented) WIC 20 Blown 44 fl- Oil' Wood _ 8 Under Attic(Unvented) BEDROOM 20 Bloom 246W 0.1 Wood _ ;9 Under Attic(Unvented) BEDROOM 20. Blown 1901t' 0.1 Wood _ 10 Under AtGc(Unvented) CLST2 20 Siam 20 ft' 0.1 Wood _ 11 Under Attic (Unvented) HALLWAY 20 Blown 139ft' 0.1 Wood ._ 12 Under Attic (Unvented) BATH 2. 20; .Blown- 67 ft' 0.1 Wood _ 13 Under Attic (Unvented) -OFFICE CLST 20 Blown 10 ft' 0.1 Wood _. 14 Under Aitlo(Unvented) OFFICE 20- Blown 172ft- 0.1 Wood _ 15 UnderAttic(Unvented) FOYER' 20 Bloom 216 ft' 0.1 Wood 16 Under Attic(Unvented). KITCHEN 20- Blom 278 fl' 0.1 Wood _ 17 Under Attic(Unvented) LAUNDRY 20 Blown 126 ft' 0.1 Wood _ 18 Under Attic (Unvented) HALL. 20 Blown 45ft' 0.1 Wood 19 Under Attic (Unvented), LINEN 20 Blown 16 ft- 0.1 Wood 20 Under Attic (Unvented) PANTRY 20 Blown 24W 0.1 Wood WALLS Adjacent Cavity. Width Height Sheathing Framing Solar Below Space _ o 1 N Exterior Concrete Bieck -Etd lnsMASTER BE 4A 15 0 9 4 140.0 fN 0 0 0.6 0 2, W Exterior Concrete Block- E)dlnstMASTER BE 4.1 17' 0 9 4. 158.7 ft' 0 0 0.6 0 _ 3 W Exterior Concrete Block -E)d lnsul MBATH 4.1 16 0 9 4 149.3 ft' 0 0 0.6 0 _ 4 N Exterior Concrete -Block --EM InsGREAT ROO 4.1 29' 0 10 0 290.0 fN 0 0 0.6 0 5 W Exterior Concrete Block- Bd lnsul. BATH 1 4.1 5 0 9 4 46.7 ft' 0 0 0.6 0 _ 6 W Exterior Concrete Block.- EM9nsul W IC T 4.1 4 0 9 4 37.3 tN 0 0 0.6 0 7 E Exterior Concrete Block- ExtImSEDROOM I 4.1 2 0 9 4- 18.7 ft- 0 0 0.6 0 _ 8 S Exterior Concrete Block- Erd lnstSEDROOM'1 4.1 '17 0 9 4 1581 ft' 0 0 0.6 .0 _9 W 'Exterior Concrete Block- Ext InsiSEDROOM I 4.1- 43 0 9 4 121.31t 0 0 0.6 0 _ 10 E Exterior Concrete Block- Ext InsSEDROOM 2 4.1 7 0 9 4 65.3 ft- 0 0 0.6 0 11 S Exterior Concrete Block-. Etd lns9EDROOM 2 4.1 14 0 9 4 130.7 ft' 0 0 0.6 .0 _12 S Exledor Concrete Block -Ext lnsui OFFICE 4.1 5 0 9 4 46.7 ft' 0 0 0.6 0 13 S Exterior Concrete Block- Ext lnsul FOYER 4.1 6 0 10 0 80.0 ft- 0 0 0.6 0 14 N Exterior Concrete Block- Ext lnsul KITCHEN '4.1 14 0 9 4 130.7 ft- 0 0 0,6. 0 15 N Exterior Concrete Block- Ext lnsull-AUNDRY 4.1 9 0 9 4 84.0 ft' 0 0 0.6 0 16 E Exterior Concrete Block• E)d InsuILAUNDRY 4:1 14 0' 9 4 130.7 ft' 0 0 0.6 , 0 _ 17 'E Exterior Concrete Block- Ext Insul HALL 4.1 5 0 9 4 4&7 ft' .0 0 ox 0, _18, E Garage_ .Frame -Wood. LINEN 11 4- '9 4 373W 0 0.25 0.600000. 0 19 ;S Garage Frame -Wood PANTRY 11 23 9 4 214.7 fP 0 0.25 0.600000 0 20 W Garage Frame -Wood. PANTRY , 11 2 9 4 10.7 ft' 0 0.25 0.600000 ,0 11812019 9A8;AM EnergyGaugaO USA Section R405.4.1 Compliant Software Page 4 of 6 FORM.R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proused orientation.; ` V # Well ._ Omt ID Frame Panes ,... NFRC -.. U-Factor SHGC Imp Area Overhang Depth 'Separation [at Shade Screening 1 -2 _ 3 4.. '5- _ 6: 7 _. 6 _ 9 10. 11 N - 1 Metal W 3 Metal N 4 Metal W 6 Metal S 8' ,Metal S 11 Metal S . '12 Metal' S 13 . Metal N 14. Metal N 15' Metal E 17 Metal Low-ESingle.. L A E'Single Low-E Single.. Low-E:Single Low-E Single Low ESingle, Lo E'Single Low-E Single.. Low-E Single Lo E Single, Lo E Single Yes Yes Yes Yes Yea Yes Yes Yee Yes Yes Yes 0.65 0,25 N 30.0it' 0.65 0:25 N 6.0 ft2 0.65 0.3 N 160.0 ft- 0.65 0.25 N 9.0 ft' 0.65 0.2611 - N. 30.0 ft- 0.65. 0.25 N. 30.0 ft' 0.65 0.25 N. 15.0 ft- .0:65 0.3' N 40.0 ft- 0.65 0.25 N 12.0 ft- 0.65 0.25 N 15.0 ft' 0.65 0.25 N• 15.0 ft 164..in 1 ft 4In I ft 4 in 1ft4In, 1 ft4:in 1ft4`In 1 ft4.in Tff 4 in 1 ft 4 in 1 lt4�in 1 ft 4In 1ft41n 9 ft 41n 1 ft 41n 1:ft 41n 1 f 41n 1041n 1'ft 41n I ft 4In 1 "ft 4 in 1114In 1 ft 4ln None None None None.. None None None : None None , None None None None. None .None None None None ,None None. None None GARAGE ` # Floor Area Calling Area Exposed Walt Perimeter Avg. Wall,Height Exposed Wall-Insulatlon 1 .. 644 ft' 644TF 29$ loft -, 11 . INFILTRATION' # Scope. Method.. SLA bFM50 'ELA EgLA ACH ACH'50' l' Wheehouse Proposed ACH(50) .000426 3086.3- 169.43: 318.64. .3256. 7 HEATING SYSTEM, # System Type. Subtype Efficiency Capacity Block' Ducts 1 Electric Strip Heatf None COPA 34 kBtulhr 1 sys#1 COOLING -SYSTEM .#- System Type Subtype Efficiency Capacity: Air Flow SHR Block Ducts 1 Central Unitl Spin SEER 16 46.6 kBtu/hr 1395 elm 0.8 1 sys#1 HOT WATER SYSTEM }) 'System Type SubType Location EF Cap' Use SetPm Conservation -_ 1 .Electric None Garage 0.98 50ga1 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM ' FSEG - -Cart # Company Name System Model# Collector Model Collector Area Storage Volume. FEF None Nona f - 102019 9:48 AM EnargyGauge(D USA Section R405A.1 CompliantSoftware , Page 5 of -6 r:naee PAnt0nm7 IMP[ IT RIIMMARY.QW11KLIST'REPORT DUCTS - Supply - - Return- Air CFM 25 'CFM25 HVAC # J 9 Location R-Value :Area Location Area -Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic '6. 200W Attic .20 ft' Default Leakage Garage (Default) c(Default)'c 1 1 TEMPERATURES _. Programabler[T'jhermostat:[ N C((oiling Fans: Coding (X1 Feb [[� [XJ Mar jj jj 17'4r [ ],Jun J E J.Jul [X� l ]AOM ug [�j t J'S p rD0' Oct NOVv ((X�� l lJan Heeling [[[( 1111 Jan LL 11 Feb. [(�x11.Mal ll�xll [ May [ ) Jun 111 Jul (] Aug l 1 Sep [XJ (]DDec ec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 '6 6 7 8 9. 10 11 12 .Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 Bo 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH). AM 78 78 78 78 78 78 78 78 80 Bo 80 80 PM 80 80 80 8o 78 78 78 78 78 78 78 78, Heatmg(WD)- AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 fib 68 68 68 68 68 68 68 68 68 Heeling:(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass type .:Area Thickness Furniture:Fraction. apace Default(8ibs/sq.ft. 0 fN 0 ft 0.3 'BATH 2 Defaulhfl lbs/sq.ft it. ft 0.3 HALLWAY Default(8.Ibs1sq'.f . ft. it 0.3 CLST 2 Defauft(8lbs/sq.fL ft' it 0.3 BEDROOM Default(B Ibsisci t ft- it 0.3 BEDROOM 3 Data ull(61bs/sq.fL ft' It 0.3 CLST 3 Default(8 lbs/sq.ft fN' ft 0.3 LAUNDRY Default(8 lbs/sq.fL ft' It 0.3 MUD ROOM .Default(8 lbs/sq.ft. fN it 0.3 DINING ROOM. Default(816s/sq.ft ft' ft 0.3 STORAGE Default(8 lbs/sq.fL ft' it 0.3 GREAT ROOM Default(B lbs/sq.ft. ,ft' A 0.3 MASTER BEDROO Default(8 lbs/sq.ft. w it 0.3 MWIC '1' Default(8.lbs/sq.fL ft' it 0.3 M CLST 2 Default(8,lbs/sq.f. W it 0.3 MBATH Default(81bs/sq.ft. ft- it 0:3 STAIRS UP Default(8 lbs/sq.fL ft' ft 0.3 GAME ROOM Default(B lbs/sqJ ft' ft 0.3 CLST4 Default(81bs/sq:R. ft' - R '0.3 BEDROOM 4. Default(8 lbs/sq.ft ft' it 0.3 BATH 3 Defaufl(B.Ibs/sq.ft ft? ft 0.3 KITCHEN Default(8 lbs/s,fL ft' ft 0.3 OPEN. Name: Rating Compant: e 1/8/2019 9:48.AM EnergyGaugcO USA Section R406.4.1 Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION • COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: CALIANDRO 3 MODEL Builder Name: DAVE GOLDEN HOMES Street: 18102BRIDLEWAY PermitOffics: ST LUCIE. COUNTY City, State, Zip: FORT PIERCE, FL., Permit Number: V Owner. Jurisdiction: ST LUCIE COUNTY m x Design Location: FL, Fart Pierce O COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA, General 'A continuous air barrier shall be Installed In the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier, not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. ceilinglattic The air barrier in any dropped ceiling/soffit shellbe aligned with the The insulation In any dropped ceiling/soffd insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Accessopenings, drop down stairs or knee walldoom to unconditioned attic spaces shall be sealed. Walls The junction of the foundationand sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be Insulated by completely filling the cavity with Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelopeinsulation for framed walls. shall be Installed in substantial contact and continuous alignment with the air barrier. Windows, skyights. The space between windowldcor jambs and framing, and and doors skylghts and framing shag be sealed. Rim joists Rim joists shall Include the air battler. Rim joists shall be Insulated. Floors The air barrier shall be installed at any exposed edge of Insulation. Floor framing cavity Insulation shall be installed to (including maintain permanent contact with the underside of abave-garage subit" decking, a floor framing cavity insulation shall and comilavered floom) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the hattorr to the top of all,perimetef flooriraming members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided Instead of floor insulation, insulation Class l vapor retarderwith overlapping joints taped. shall be permanentlyattached to the crawlspace wails. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shag be sealed. Betts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and core lfloned spaces. Recessed lighting Recesseddightfoduresdnstalled inthe building thermal envelope shall Recessed light fixtures Installed in building be sealed to the drywall,: thermal: envelope shall be air fight and IC rated. Plumbing and wiring Batt insulation' shall be cut really to fit around wiring a plumbing In extedor walls, or Insulation that on Installation readily conforms to available space shall extend behind oilding and i' Showerhub The air barrier. Installed at exterior walls adjacent to showers and Exterior walls: adjacent to showers and tubs shall be on exterior wall lubs shaft separate them from the showers and tubs. insulated.. Electricallphone box on The air barrier shall be installed behind electrical or communication exteriorwalls boxes or air-sealed'boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed-. When required to besealed, concealed fire sprinklers shall only be: sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill vdds between fire sprinkler cover plates and walls or cellincts, a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 11812019 9:50 AM EnergyGaugeO USA FBC 6th Edition (2017) Compliant Software :Page l of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCELEVEL (EPL), DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12.'Ducts, location & insulation level ' a). Supply ducts R 6.0 2. Single-familyor multiple family 2. Single-family b) Return ducts 'R 6i0 c) AHU location Attic/Attic 3. No: of units (if multiple -family) 3. 1,, 4. Number ofbedrooms 4. 3 13. Cooling system: Capacity 46.5 a). Split system SEER 16.0 5. Is this a worst case? (yes/no). 5, No b) Single package SEER c) Ground/water source SEER/COP. B. Conditioned floor area (sq. ft.) 6. 2764 d) Room unit1PTAC EER e) Other 7. Windows, type and area a) U-iacton(weighted average) 7a. 0.650 6) Polar'Heat Gain Coefficient (SHGC) 7b. 0,278 14. Heating system: Capacity 34.0 c) Area 7c. 362.0' a) Split system heat Pump HSPF b) Single package heat pumpHSPF 8. Skylights c) Electric resistance COP 1.0 a)= U•factor..(weighted average) 8a: NA d) Gas furnace,natural gas AFUE b) Solar Heat Gain Coefficient (SHGC). 8b:. NA. e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a)'Slab-on-grade (R-value) 9a. 0.0 b),Wood, raised (R-value) 9b. 15. Water heating system c),Concrete, raised (R-value) 9c. a) Electric resistance. EF 0.98 ' b) Gas fired, natural. gas.. EF 10. Walrtype and insulation: c) Gas fired; LPG EF A. Exterior. d) Solar system with tank EF 1.' Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump With tank EF_ 2: Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) lost. 11.0 2. Masonr"(Insulation 'R=value) 1082, 16, HVAC credits claimed (Performance'Metfiod) 11.. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a.. 20.0 b) Cross ventilation No b) Single assembly 11b. c) Whole,houseLfan No c) Kneewalls/skylight walls 11c. d) Multizone cooling credit d) Radiant. barrier Installed 11d. No 'a)'Multizone heating credit f) Programmable thermostat No 'Label required by Section R303,1.3 of the Florida Building, Code,_ Energy Conservation, if not DEFAULT. I certify that this home.has complie 'th the Florida Building Code, Energy Conservation, through the above energy saving features which will 6e ins a (or exceeded in thishome before final Inspection. Otherwise,. anew EPL display card will be,completed b on in lied de compliant features. Builder Signature: Date: ,vI Xs; Address -of New Home: 18102.BRIDLE WAY City/FL Zip: FORT PIERCE. FL 118/2019 9:49:53 AM EnergyGauge®USA 6.0.02 - FlaRas2017 FBC eth Editim'(2017) Compliant Software Page l of 1 n Project Summary FILE COPY Date: Oct 02, 2018 -F�- wrightsoft Enure House By: QUICK CALCS, INC. 317 STLUCIE LANE, FORT PIERCE. FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM Project For. CALIANDRO 3 MODEL, DAVE GOLDEN HOMES 18102 BRIDLE WAY, FORT PIERCE, FL seey�►e® Notes: St• Lucie COunty Pesign Information Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 26643 Btuh Structure 22011 Btuh Ducts 9120 Btuh Ducts 12996 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 35764 Btuh Use manufacturer's data in Rate/swing multiplier 0.95 Infiltration Equipment sensible load 33256 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3925 Btuh Ducts 3623 Btuh Heating g Cool' Central vent 0 cfm) 0 Btuh Area (ft� 27 2764 Equipment la ent load 7548 Btuh Volume (fts) 26256 26256 Air changes/hour 0.32 0.16 Equipment total load 40804 Btuh Equiv. AVF (cfm) 140 70 Req. total capacity at 0.70 SHR 4.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6049B1 AHRI ref Coil TEM6AOD48H41++TDR AHRI ref 7567557 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER - Heating input 9.5 kW Sensible cooling 32650 Btuh Heating output 32411 Btuh Latent cooling 13950 Btuh Temperature rise 19 OF Total cooling 46500 Btuh Actual airflow 1550 cfm Actual airflow 1550 cfm Air flow factor 0.043 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.82 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrighttsoft- 2016-Oct-02 b6:40:05 Right -Suite® Universal 2017 17.0.08 RSU08101 Page 1 EADocurmets\Wnghtsoft WAMCALIANDRO 3.mp Cate =MJ8 Front Door bees: S a wrightsoft Right-JO Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: Oct 02, 2018 By: 1 2 3 4 5 Room name Elposed wall Room height Room dimensions Room area Entire House 194.0 It 9.5 ft 2764.0 ft2 MASTER BEDROOM 320 It 9.3 It heal/cod 15.0 x 17.0 ft 255.0 ft2 Ty Construction number U-value (BtuIVfF-'F) Or HTM (Btulvft2) Alea (1`0 or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Bluh) Heat I Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cod 6 11 Yfr -- II��-GG W !. —G 12/ ��(C` _-... IW E2I--c� G ,... 13A4ocs - 2 glazing, dr laa-e 2 glazpg, Ur Ioµe 2 glazing, clr.l�__ 13A-0acs 2 alazino..Ur lowc._-._ 13AAocs 2glazing cir to a 2glazing Gr Ew,e „..:...,,_0650 13A ws 2 glazing, Ur 10 2 alazino. U{ lave .. 16A-30ad 1 -(f.143650 0.650 0.650 ._ _0.650 0143 _.. 0.650 0.143 0.650 0,143 0.650 0.650 ,. 0,032 n n n .n_ a _ e,,..„._.18.20 s s _s_ w w w , .. 4 00 18 20 18 20 __._18.20 4.00 4.00 18.20 ,::_J8.20 4.00 18.20 18.20 ...e .,0.90 ' i 210 14.99 14.99 _14.99 219 _.. 33.77. 219 14.99 ._.1499- 2.19 33.77 33.77 -.. 224 612 12 45 _ --161 260 __ _.15.. 415 75 ,,,-,_,40 612 6 9 _,- 2764 _ 420 : 0 0 ---_0 245 0 300 75 40..........732 497 0 0 .,, 27641 '1218 819 818 _ v.2927 983 ----- 273 1200 1365 1988 109 164 2477 ' ^.- 18 675 675 _._._..2411 537 '.'__.. 507 655 1124 .„, ,..„._603 1086 203 _ . ,... 304 6191 _740„ 0 30 __.,..0 0 -..___. _ 0.. 0 0 ,.-.... ..0 158 0 0 255 110 0 0 0 _-_ _ 0 0 0 ,.,0 158 0 - 0 _. :255: 430 0 546 0 ._0. 0 0 _....,. 0 633 0 -_ _ , 0 _ 228 - 240 0 450 _0 0 _...._._ _0 0 0 .__.'0 346 0 ._ 0 .. 571. F......._.. _. - 22A-tph_ _..-» _ .. __. ...1.358 _. 3802 0.00 2764 ... ,_1&_t ._, .,._7377 0 ... _. 255,. s - 32 1217 _..... _....0 61 c)AED excursion 1 1 0 1 1 -40 Emelope loss/gain 22334 15407 3063 1567 12 a) Infiltration 4309 1154 701 188 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliancestother 5450 1500 Subtotal (lines 6 to 13) 26643 22011 3763 3254 Less adenal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 26643 22011 3763 3254 15 Duct loads 34% 59% 9120 12996 34% 500 1288 1921 Total morn load 35764 35007 5052 5176 Al(cfm) 1550 1550 219 229 .&A -FIf wrightSOf ' Right -Suite® Universal 2017 17.0.08 RSUD8101 EADocurn els\Wrightsoft WACICALIANDRO 3.rup Calc = MJ8 Front Door faces: S 2018-Oct-02 08.40:05 Page 1 t wrightsoft• Right-M Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE. FORT PIERCE, FL 34946 Phone: 772-4666799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM Job: Date: Oct 02, 2018 By: 1 Room name M BATH M TOILET 2 3 Exposed wall Room height 16.0 ft 9.3 ft heatt000l 0 8 9.3 It beat/cool 4 Room dimensions 1.0 x 172.0 ft 4.0 x 5.0 ft 5 Room area 172.0 W 20.0 IF Ty Construction U-value Or HTM Af (fly Load Area (ft� Load number (BtUIVW'F) (Btuh/ft0 or perimeter (ft) (Bluh) or perimeter (ft) (Btuh) Heat Cod Gross I WP/S Heat Cool Gross I WP/S Heat Cod 6 4t! -... -13A4ocs - 0.&90 n 9 u u u u u. o 0 2 glazing, Gr lyre 0.650 n 8.20 18.20 4. 14.99 0 0 0 0 0 0 0 "0 0 2glazing drfwi-e 0.650 n 18.20 14:99 0 0! 0 0 0 0 0 2 gI&ng;drla __0.650 _.�. _n_ __:18.20 _14.99 --_.0 0 0 11 _...� IN ,w,e__. 13A-0acs 0143 a 4.00 219 0 0 0 0 0 0 L_.G. 2olazm,cIrlcw-e,_._ „__,__0.650 ,....?__.._18.20 ._.33.77 _...0 0 ._.._..., ,_0 ..,__...........9-.�___._9 0 0 .__.___0 0 _..__...__0 0 _ -___0. 0 W '13A4= 0143 s 400 2.19 0 0 0 2 glazing, Galax-e 0.650. s. 1820 14,99 0 0 0 0 0 0 0 0 2glazin9,drlmv-e .-1118.20 _14.99 .,_ ..._.._ 0 -., .. A .._ 0 _-- ---0 ._..,0'_.. - _..0 „_-0 ...». ._....._0. , .'_.,. 13A4ocs _.A,650„s. 0,143 w 4.00 2.19 149 143 572 312 0 0 0 0 LsI--(i Ls 2 glazing, dr low-e 0.650 w 18.20 33.77 6 0 109 203 0 0 0 0 2 olazirp or Ivvc 0.650 w,. 18.20 _ 33.77 0 0 ,. - 0 0 0 _ _ 0 , 0 _ __ _ - 0 .0 _.'._ 16A-30ad „ ,. -_ , _ 0.90 224 - 172 _ ;.: 172 154 .385 20 '... .20. ._ „18 _ 45 F-._..-... _:.. 22A-toh _..._..._ ..__0032. 1.358 _-..._. 38.02 __.__0.00 172,--,--- _ 1.6 _..-.._608 0 �._._._20 .._..-"0 0 ._0 6 c)AEO excursion 72 A Envelope loss/gain 1443 973 1 18 41 12 a) Infiltration 350 94 - 0 0 b) Raom ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliancestother 0 1 300 Subtotal(lines 6to 13) 1794 1037 16 341 Less edemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 2 5 14 Subtotal 1794 1067 20 346 15 Duct loads 34% 59% 6141 630 34% 59% 7 204 Tolal room load 2408 1696 27 550 Air required(cfm) 104 75 1 24 C A4- Wrilghtsoft' 2018-Oct-0208:40:05 Right -Suite® Unlvarsal 2017 17.0.08 RSU08101 Page 2 .�CEA E9Documnets\Wrighlsoft HVAC\CALIANDRO 3.rup Calc = MJ8 Front Door laces: S w F�t wrightsoft Right- JO Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772.466.6796 Email: DUICKCALCS@AOL.COM Job: Date: Oct 02, 2018 By: 1 2 3 4 5 Room name E)prsed wail Room height Room dimensions Room area GREAT ROOM 29.0 ft 10.0 ft heat/cool 1.0 x 571.0 It 571.0 ft2 M WIC 0 It 9.3 If heat1cod 9.0 x 11.0 It 99.0 ft2 Ty Construction number U-value (BtulUWt F) Or HTM (Btuh/ft� Area qtl or penmeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Stuh) Heat I Cod Gross N/P/S Heal Cod Gross NIP/S Heat I Cod 11 I-G W r- 2 glazing, cir low-e 2 glazing. dr love 2glazing, dr.loa-e- 13A-0acs 1 1 1 0143 :0 650 0.650 -._0.650 0.143 0 650 n n n ,n a a '._ 4 00 16.20 18.20 _,- 1820 4.00 1820 2.19 14.99 14.99 ..,,,. 14.99 2.19 33 77 290 a 0 _ _.__161 0 0 129 0 0 .__ _ _.0 0 0 ' Wy517 0 0 ,.,._: 2927 0 0 _ 283 '.0 0 v...---- 2411 0 0 -0 0 0 0 0 0 _- ,0 0 0� 0 0 _..- 0 0 0 0 0 0 0 0 0 0 i _ 2a azn0.,.a r. _400 �_- 219 .0. _ 0 0 '0 .U...... 0 .. _.� 0 _ .-0 N�1 13A-0acs 2 glazing, dr h" 0143 0.650 5 s 18.20 14.93 0 0 0 0 0 0 0 0 `AGO _. s_.,,,.._9820 _..14.99 ......,. -_P ._. _0 _.....,'L _0_ 0_ 0._ _..,.., .0._...,_...._0 ._..._.0 _._..:2glazIpgdrldN-e_......_,._0650 <N 13A-4= 0,143 w 4.00 219 0 0 0 0 0 0 0 0 2 glazing, dr lci -e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 alazinp lc we 0.650 w 18.20 33.77 0 0 _ _ 0 0 _ 0 ._ 0 ._ 0 _ 0 C„�_ _dr „ 16A-30ad ��,_0.032 . r , ._ 0.90 _,. 2.24 _ ` ,. 571 ,571 __. ,- 512 _ 1279 __,99 . - 99 .. 89 ..,, 222 F __._... 22A-lph__._. 1.358 - -... __36.02 ___ Q.00 _ 571 ..,. , 29 .._,... 1103 _...,.. _01 "` ___ 99 6 c)AED exursion -50 -3 Envelope Icss/gain 5058 3922 89 219 12 a) Infiltration 683 183 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances other 0 0 Subtotal (lines 6 to 13) 5741 4105 89 219 Less odemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 11 27 44 110 14 Subtotal 5752 4132 133 329 15 Duct leads 34% 59% 1969 2440 34% 59% 46 194 Total mom load 7721 6572 179 523 Air required(crm) 335 291 8 23 /ALA -Fp- wrightsoft- 2018-Oct-0208:40:05 Right -Suite® Universal 2017 17.0.08 RSU08101 Page 3 E:1DocurmelslWdghtsat HVAC1CAUANDRO 3.mp Cole =MJ8 Front Door faces: S F�F wrightsoft Right-M Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL,COM Job: Date: Oct 02, 2018 By: 1 2 3 4 5 Room name Ugxsed wall Room height Room dimensions Room area BATH 1 5.0 ft 9.3 ft 11.0 x 5.0 55.0 W heat1cool ft WIC 1 4.0 ft 9.3 It 11.0 x 44.0 ft2 heat/cool 4.0 ft Ty Construction number U-value (BtulVft2-"F) Or HTM (Btuh/ft0 Area (ft2) or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Btuh) Heat I Cod Gross N/P/S Heat I Cool Gross N/P/S Heat Cool 6 __ .. __..__. 13A-0ocs. 0,143. .-_. - q _.. 4.00 .. 2.19 . 0 _ ._ :" a 0 - _ 0 .__.. .. '0 _"0 0 0 ,.__. 0 I-G 2gluing clr lcw-e 2glazmg, clr 11 2glazmg.draav-e . '0,650 0,650 . ..:0.650-n.. n n '18.20 18.20 _._18.20 14,99 14,99 .14.99 0 0 0 - 0 0 0, 0 0 ._.._.0 -0 0 ;...0 0 0, _�. ,0,....:_._.,. 0. 0. 0...._.__.__...0 0 0 0 0 .___�0 II----GG. �..._, 11 W, 13A-0acs 0143 a 4.00 219 0 0 0 0 0 0 0 0 . __.-,_. 2alazino,. clr Im-e _. _0650 _e ,.,__1620 ... 33.77 ... „,,,,-0 -. 0 0 __.„,_0 ,.-., 0 ,.0 0 0 ,...0 '0 W m4ocs 0143 s 400 219 0 0 0 :0 0' 0 Lrg 2 glazing cIr Iow-e 0,650 s 18.20 14,99 0 s 0 0 0 0 0 0 0 291azi08. Ur_Iwu-e _._ _0.650 „-s, 1820 14.99 .--_„.0 >:.-. 0 0 , �0. ____„_0 0, ... __0 ._._... 0 _ . 13AAccs 0.143 w 4.00 2.19 47 38 150 82 37 37 149 81 IW I--ts 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2glazlnq, clr lav-e__ 0.650 w 1820 33.77 9 �, 0 164 304 _ 0 0 0 0 _-,-, . C i6A-30ad 0.032 . '> 0.90 .224 55 55 - ; . 49 .. . 123 44 44 _ 99 99 _ _ F 22A-tah _ _. 1.358 _. 38.02 ..0.00 ..,, ,.,._55._. 5 ,_. ,,... ,190 _.. __.0. _-.44. 4,.....,. 152. __.._,.-0 61 c) AED excursion 1 1 120 1 1 -6 Envelope loss/gain 1 553 629 340 174 12 a) Infiltration 109 29 88 23 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 300 Subtotal (lines 6 to 13) 663 659 428 497 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 11 27 0 0 14 Subtotal 674 686 428 497 15 Duct loads - 34% 59% 231 405 34% 59% 147 294 Total room Ind 905 1091 575 791 Airrequired (cfm) 39 48 25 35 �4jf+- wrightsatV 2018-Oct-0208:40:05 Right -Suite® Universal 2017 17.0.08 RSU08101 Page 4 E:\DocumnelsMirightsoll liWAC\CALIANDRO 3.rup Calc=MJS Front Door faces: S wrightsoft' Right-JO Worksheet Job: Entire House Date: Oct 02, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772.4666796 Email: OUICKCALCS@AOL.COM 1 Room name BEDROOM 1 BEDROOM 2 2 3 E>Posed wall Room height 32.0 It 9.3 ft heat/cool 21.0 It 9.3 ft heat/cool 4 5 Room dimenecns Room area 1.0 x 245.0 R 245.0 ft- 1.0 x 19D.0 ft 190.0 ft' Ty Construction U-value Or HTM Area (ft5 Load Area (ft� Load number (Stuh/ftMF) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Bluh) Heat I Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool e U(/---� {—G -13A-0ocs ....... N18.20 2 glazing dr lce 2 glazing dNrlce .. _. 0143 650 O 0.650 n_ n n —_. -4.00 18 20 18 20 '-fig 14.99 14.99 0-- 0 0 0 0 0 0 0 0 _ ...0_0 0 :0 0 0 0 0 0 0 0 0 �I—(r,' 2 glazing,. dr. loi*e..._.. —0850 n_ ___18.20 --14.99. 0 __0 _ _._ 0 -- _.- 0 0 ----0-- o - -----0 — 19 19 261 11 13AAccs 0.143 e 4 DO 219 74 41 65 65 142 IIN L-G, W WG 2 glazing clrlow a 13A46cs 2 glazing, dr Iox-e ,,,,_0 650 0143 0 650 a s 3 18.20 '_- 4.00 18.20 33.77 219 14.99 0 �158 30 0 128 30 - _ 0 513 548 _-_ ,., 0 280 450 __ 0- 130 30 0 1DO 30 ........ 0 401 546 - „ 0 210 450 _`_'. :2glazing,drao:r-a„-„._,.;0650„s-, _... 1820 14.99 , ,OL._._,..0 ,,..... ... 0_ 0 .,,,,-.A.. ........ 0.. ._ 0 _._,,._.,0 13AAccs 0.143 w 4.00 2-19 121 121 484 265 0 0 0 0 C -... 2 glazing cir love 2glazim dr lawe 16A30atl ,.. . ,-,_.0032 0.650 _0650 w w - - 1820 1e20 0.90 33.77 33.77 ._._224.._.^..245 0 0_._ 0 0, .,245 0 0 220 0 0 , � _ . 549 0 - 0, , 190 0 - _ 0_- i _ 790 0 ._. 0.,,, _ _ 170 0 0 426 F__ 22P.tph _._ __— 1 358 - .:___38.02 .. _ 0.00 245 -_32 --- _ __-1217 __0 _ ___1_90 --21 . 799 ___..—_0, 6 c)AED emursion -21 -19 Envelope loss/gain 3054 1563 2177 1218 12 a) Infiltration 701 188 460 123 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 200 Subtotal Qirres 6 to 13) 3754 1750 2636 1541 Less edemal load 0 0 0L2529 Less transfer 0 0 0 Redistribution 13 33 20 14 Subtotal 3768 1783 2656 15 Dud loads 34% 59% 1290 1053 34% 59% 909 Trial morn load 5058 2836 3565quired(dim)219 126 155 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsof ' 2018-Oct-0208:40:05 Right -Suite® Universal 2017 17.0.08 RSU08101 Page 5 EADocur nelslWrighlsoft HVAC\CALIANDRO 3.rup Cale = MJ8 Front Door faces: S wrightsoft• Right-M Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE. FORT PIERCE. FL 34946 Phone: 772-066-6799 Fax 772466.6796 Email: OUICKCALCS@AOL.COM Job: Date: Oct 02, 2018 By: 1 Room name CLST 2 HALLWAY 2 ErPosed wall 0 It 0 It 3 Room height 9.3 It heat/cool 9.3 It hwttcod 4 Rcom dimensiaru 10.0 x 2.0 ft 1.0 x 139.0 It 5 Roomarea 20.0 It- 139.0 W Ty Construction U-value Or HTM Area M Lead Area (ft5 Load number (Btutdit"F) (Btuh/ft' or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIPIS Heat Cool Gross WPIS Heat CoU _ 6 �_ M1 13A-0ocs". .... ......_._0:143- n -' 400 �2.10 0..... ,.0 ,_._._- .p'.,0 0... _ 0.....,,- ..0 - 0 11 —._ _. w -- Y E ..„.t IW I--G C _. 2 glemng, clr:lox-e _ 9 13AAccs 2 alwina. cir lower_. 13AAocs 2 giezirg, dr loµe 2glazing.clr lave_.__....,...: 13AAcc I 2 glazing, cir lace 2alazino, dr lof e- 18h30ad 22A-tph ___.... ., . _._.._ .0 650 0.143 0.650 0.143 0.650 0.650.s._:_18.20...,,_:14.99. 0.143 0.650 0650 .m0032 _._ 1,358 _n _ a e_- s s w w w _„'-. ._y._ 18 20 �..:18.20 4.00 _ ,., 18.20 400 18.20 4.00 18.20 -,1820 ,- 0.90 .-._38.02 14.99 --14.99- 219 33.77 219 14.99 219 33.77 33.77 224 , .___0.00 0 _ ,.,0 0 _.0 0 0 0 0 0 0 _.. 20,20 mm. 20 0 __.___.._0 0 0 0 Ty 0 ,0_..--.0 0 0 0 20 _ .. 0 . 0 _....._..-__ 0 0 .. __0 0 0 0 0 - o 18 _. „. _0. 0 _......_40 0 . w. _._._._o 0 0 ----0 0 0 00, ., 45139. m,. _0 0': __`0 0 ..,__. _ 0 0 0 _.. _.....: 0 0 0 _ 0 .w _139 0 __...._._0.__�_ 0 -_.. _._.._ _0 0 0 __--_0 0 0 -- 0 _ .,139 _.. ...._..0 -0 0 _�_....,0 0 0 0 0" 0 _..0 .._, ,125 ..-.,..n ...._9 0 0 _........ _._o 0 0 ,_.."0 0 0 - 0 _... 311 '_ ' _ _0 6 c) AED ercursion -1 -4 Envelope loss/gain 18 44 1 125 308 12 a) Infiltration b) Room ventilation 0 0 0 0 0 0 0 0 13 Internal gains: Occupants QQ 230 Appliances/other 0 0 0 0 0 0 Subtotal pines 6 to 13) 18 44 125 30B 14 15 Less eAemel load Less transfer Redistribution Subtotal Duct loads 34% 599% 0 0 -18 0 1 0 0 0 -44 0 0 349% 59% 0 0 -125 0 0 0 0 -308 a 0 Total room load Air required (cfm) 0 0 0 0 0 0 0 0 p'Fp- wrightsaft' 2018-Oct-0208:40:05 Right-SuileO Universal 2017 17.0.08 RSU08101 Page 6 EADocurmets\Wrightsoft HVAC1CAUANDRO 3.mp Cole =MJB Front Door faces: S 0 AL wri htsoft Ri Right-JO Worksheet Job: 9 g Date: Oct 02, 2018 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area BATH 2 O ft 9.3 ft heat/cool 1.0 x 67.0 It 67.0 W OFFICE CLST O ft 9.3 ft heat/cool 5.0 x 2.0 ft 10.0 ft2 Ty Construction number U-value (Btuh/1`02F) Or HTM (Btuh/ft5 Area (ftl or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (6tuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 4p/ " 1{{--.----GGG . W, _._.._..2 W ..--.,G IW I-O i---G C , _ F- 13A4ncs- 2glazing, or foNe 2 glazing, clr towe 2glazing, clr.loa-e _ 13g4acs glazing. Grlowe 13A4ars ' :2 glazing dr lc : e 2 glazing dr lox-e .�.... 13A4ocs 2glazing, clr low-e 2 plazino, or tv:i-e _ 16A-30ad 22A-tph. _ '. -0143 0650 0650 .....:0,650 0,143 650 0143 0143 .0 650 _ . _;0 650 0.143 0.650 0650 A 032 1358 n in n -n,- a a„__.._14.00 s a s w w w _. 4 00 18.20 '1820 _..,:18.20 4.20 4.00 18.20 18.20 4.00 18.20 1820 D 90 3802 219 14.99 14.99 - _ 14.99 2.77 ,.. 3219 219 14,99 _ 14.99 2.19 33.77 33.77 2.24 ..-, 0.00 _ 0",-, 0 0 -. 0 0 -. _0 0" 0 ,.,... _....:0 0 0 0 67' - 67 0 0 0 _ ... 0 0 .w_.. .. ..,0 0 0 _„ 0 0 0 0 67 -0 -0- 0 0 ____ _ 0 0 .__._ .,.0 0 0 .... 0 0 0 0 60 .. �y--_„0 ...0 '0 0 _.. _. . -0 0 _..0 0 0 _. _ '0 0 0 0 150 ,-„_. --0 _ 0' 0 0 . .0 ...... 0 .-„.,..-..0 0� 0: , _ 0 0 0 0 '10 _. 10 0 0 0 7-.-_ .0 ,. 0 .„. _._0. 0 0 „ ._ .0 a 0 0 10 .. 0 0 0 --------- 0 0 .._.„ .0.. 0 0 0 0 0 _ . 0„ , 9 _. '0 0 0 ._ ., ., 0 0 _ .. ,0 . 0. 0 ,------0 0 0 _ 0 22 6 c)AED mursion '4 0 Envelope loss/gain 60 146 9 22 12 a) Infiltration b) Roomvenfilation 0 0 0 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 200 0 0 0 Subtotal pines 6 to 13) 60 346 9 22 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 34% 59%1 0 0 12 72 25 0 0 29 375 222 34% 59% 0 0 -9 0 0 0 0 -22 0 0 Trial room load Air required (rim) 97 4 597 26 0 0 0 0 A -rFr wrighYSoft' 2018-Oct-02 08:e 7 Right -Suite® Uni�rersal 2017 17.0.08 RSU08101 Page 7 E:\Documnets\Wrightsofi WAC\CALIANDR03.rup Calc=MJ8 Front Doorfaces: S r{a wrightsoft• Right-M Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM Job: Date: Oct 02, 2018 By: 1 2 3 4 5 Room name EVosedwdll Room height Room dimensions Room area OFFICE 5.0 It 9.3 It heat/cool 1.0 x 172.0 ft 1720 ft- FOYER 8.0 It 10.0 ft heat/cool 8.0 x 27.0 it 216.0 ft2 Ty Construction number U-value (BtuNft-9 Or HTM (Btuh/ftl Area (ft2) or Perimeter (ft) Load (Btuh) Area (ft2) Cr Permeter (it) Load (Btuh) Heat I Cool Gross N/P/S Heat Cod Gross NIPS Heat Cod e W, 13A4ocs 0143 n A 00 ' 219 0 '�_ U �� U _ _ 0 ' - 0 0 0 0 2 glazing, or lox-e 0650 n 1820 14.99 0 0 0 0 0 0 0 0 2 glazing, or Ip 0650 n ':1820 14.99 0' 0 0 Q 0 0 0 0 2glazing Grlowe_. __- ._0650 _n, -..-18.20 _14.99 _ _ 0 ---0--- _ 0-_.__ o-0 _ _. _0 _...__.-0 11 W, 13AAms 0.143 a 4.00 219 0 0 0 0 0 0 0 0 G 2 plazino dr Iwr-e 650 e_ 18 20 - 0 0 - 0 0 -_ 0 -, 0 _...._. 0 0 W, 13A4ocs „ .-„--_0 0143 s -,-„- 4.00 _33.77 219 - 47 „-, 32 126 -69 80, 40 159 87 2 glazing dr lc e 0.650 s 18.20 14.99 15 15 ' 273 225 0 0 0 0 _.� 2glazing, drlowe - , .__0850_a_,-._18.20 _14.99 _, m0.„._ , 0 ... ..._. ,0 _,-,,,_..0, 40 :...,_ 40.._.._.,603 W 13A-4ccs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 LG2 glazing dr lows 0.650 w 18.20 33.77 0 0 0 0 - 0 0 0 0 2 plazinp clrlow-e w- ,_1820 33.77 0 0 _,,,, 0 _ 0 _ 0 ,- 0 �� �.... 0 - 0 C -_, i16A-30ad ,.. „0550 0.032 - 0 90 - ` 2.24 172 '. 172 >.'154 . , .38J` .216 ..- 216 194 484 , F ..- 22A-tph_._.. _ _.1358 -._.___, _. 38,02 .__ 0.00 _ .-_ 172 5 __.. .._190 _ _ 0 _216__-_8--. _-0 6 c) AED excursion -15 e Ernelope loss/gain 743 664 1389 1182 12 a) Infiltration 109 29 188 50 b) Roomventilation 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 0 0 Appllances/other 500 350 Subtotal (lines 6 to 13) 853 1194 1577 1582 Less edemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 38 93 0 0 14 Subtotal 890 1287 1577 1582 1151 Duct loads 34% 59%1 305 760 34% 59%1 540 934 Total room load 1195 2046 2117 2516 Air required(cfm) 52 91 92 111 �C`.P. � wrightSOft- 201&Oct-0208:40:05 Right -Suite® Universal 2017 17.0.08 RSU08101 Page 8 E:\Documnets\Wdghtsoft HVAC\CALIANDRO 3.mp Celc = MJB Front Doorfaces: S wrightsoft Right-JO Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fatc 772466-6796 Email: OUICKCALCS@AOL.COM Job: Date: Oct 02, 2018 By: 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area KITCHEN 14.0 It 9.3 It heaticool 1.0 x 278.0 It 278.0 ft2 LAUNDRY 23.0 It 9.3 It heal/cool 9.0 x 14.0 It 126.0 ft2 Ty Constnlction number U-%thus (Btuh/ft2-°F) Or HTM (BtuWftO Area (fl0 a Perimeter (ft) Load (Btuh) Area (ft� or perimeter (ff) Load (Btuh) Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cad 6 11 V)✓ IFS--C--GG W L—G. 2 Ulmi g, ' '" 2 glazing, Ur lov-e 2 glazing, dr low-e 2glazirg,.dcla __._._0.650—n 13A-0acs 2 dazing sUr lovre_ _. 13A-4ocs 2 glazing Ur 1d 2 alazmc., dr lave 0143 0,650 0,650 0143 0.650 0.143 0.650 . _..:0 650 n n n a _ e_ s s . s . 4 00112 18.20 18.20 _-_1820 4.00 __ 18.20 4.00 18.20 _ :_18.20 14.99 14.99 ._14.99 219 33.77 219 14.99 .. 14,99 12 0 _ __0 0 _. 0 0 0 . .:0 - - 110 , 0 0 "0 0 .__ .. 0 0 0 .-:.. ,,. 0 W 473 218 0 0 _ ........__ 0 0 0 - .:... _ 0--,, 4 LL W 259 180 0 0 _ 0_,_ ;0 0 -0 ' 84 0 15 130 0 0 0. .: - 69 0 0 __a 130 _.__�,_ o 0: 0 -- -„_ ._-_ 0 275 0 273 �. 0 521 ._. 0 0 0 „._ .. 0 -- 150 0 225 _._,0 285 ._ ._ ,_0 0 0 ..__.......0 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 Lam; 2glazinq, cir1cw-a-,_,_ 0.650 w ie.20 33.77 :__ _. 0 0 0 0 _ 0 _ 0 0 „- 0 _, ,. :0:032 - - 0.90 224 _ .278 _ 278 -249 _. 623 726 '. _ 126 113 - 282 . - .. 1.3W - - 3802 _0.00 _.._278..__,-._14 532 ..____..0___ 126 ,_-23 --- ----- -875---- --- 0 6 c)AED excursion -32 -13 Envelope Ims/gdn 1473 .1029 2057 929 12 a) Infiltration 307 82 504 135 b) Rcom serf ilatian 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1500 0 Subtotal (lines 6 to 13) 1780 2611 2560 1064 Less exdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 231 227 416 408 14 Subtotal 2011 2838 2976 1472 15 Duct loads 349/6 59% 688 1678 34% 59% 1019 869 Total room load - 2699 4514 3995 2341 Air required(cfm) 117 200 173 104 .�, �7- wrightsoft. 2018-Oct-0208:40:05 Right-SuiteG Universal 2017 17.0.08 RSU08101 Page 9 E:1DocumnetslWrighlsafi HVACICAUANDRO 3.rup Calc = M M Front Door faces: S qt wrrightsoft, Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM Job: Date: Oct 02, 2018 By: 1 Room name HALL LINEN 2 3 Eked wall Room height 5.0 ft 9.3 ft heat/cool 0 ft 9.3 ft heat/cool 4 5 Room dimensions Room area 9.0 x 5.0 It 45.0 ft' 4.0 x 4.0 ft 16.0 W Ty Construction number U-value (BtuMt;'F) Or HTM (Btuhrft� Area (M or perimeter (ft) Load (Btuh) Area (ft=) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/5 Heat Cool Gross N/P/5 Heat Cool 6 477 _ I--G 13A4065 _ 2 glazing Ur lave 2 glazing Ur lwre .0143 '0 650 oW n n n 4 00 18,20 18 20 _ 219 14.99 14.99 c 0 0 0 0 0 0 `:. 0 0 0 0 -0 0 o D 0 - . 0 0 0 0 0 0 0 0 . L�__.GG ._.., 291azrng,.Ur.loN-e .._ ._0,650 _-n ,..-�18.20 ,_14.99 Oi 0......__.-_0 ---- -0 11 w 13A4ocs 0.143 a 4.00 219 47 32 126 69 0 0 0 0 4�l _. 13A-0ocs - ..... 0143 "s '4.00 2.19 0 0 0 0 0 0 0 0 �G :2 glazing, Urlov-e - 0,650 s„ 1820 14.99 0 0 0 0 0 0 0 0 12 glazing, Ur low-e _ 0.650 s - 16.20 14,99 0 0 0 _ ,0 ......,. 0 _ _.. _ 0 13A4ocs 0.143 w 4.00 2.19 0 0 0 0 0- 0 0 0 IWI - 2 glazing, Ur low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 alazinq, clr lw+-e 0 650 w 18.20 33.77 0 0 „ - 0 ,- 0 _ _ , 0 , ,., 0 0 0 C , �.." '16A-30 _ `0.032 -.. b,90 2.24 45 ' 45 , , - ' 40 ., 101 16 16 ,. .. 14 . 36 F_- _.. , 22A-tgh _............ ..... _ ..m .1 :358 -. _. 38.02 . _ 0.00 45 ., 5 _ _ _190 ..... _16 .__, .._ a .,. , W _ 0 ,.. ., 0 E - I- --I , ,:..I ... _:r- 6 c)AED elcursion 1 19 4 Em,elope loss/gain 630 696 14 32 12 a) Infiltration 109 29 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 300 Subtotal (lines 6to 13) 739 725 14 332 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -739 -725 92 91 14 Subtotal 0 0 107 422 15 Duct loads 34% 59% 0 0 34% 59% 37 249 Total room load 0 0 143 672 Air required (Um) 0 0 6 30 2018-Oct-02 08:40:05 Page 10 A wrightsoft' Right -Suite® Universal 2017 17.0.08 RSU08101 E:\DccumnetsMrightsoft WAC\CALIANDRO 3.rup Cato =MJ8 Front Door faces: S wrightsoft Right-M Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE. FORT PIERCE, FL 34946 Phone: 772-466-6799 Fas 772-466-6796 Email: OUICKCALCS@40L.COM Job: Date: Oct 02, 2018 By: 1 Room name PANTRY , 2 3 F)glosed wall Room height 0 It 9.3 ft heat/cool 4 Room dimensions 6.0 x 4.0 ft 5 Room area 24.0 W Ty Constmctim number U-value (BtuNftk°F) Or HTM Area (ft� or perimeter (ft) Load (Btuh) Area or perimeter Load Heat Cool Grass N/PIS Heat Cool Gross I NIP/S Heat Cod 6 -._. ,184-466s _..-.._ _._._ -0143 n 4.00 239 - _ - -'a-- 0:" 0 0 (--G 2 glazing, dr lc v e 2 glazing, cir lure 0.6w 0.650 n n 1820 '18.20 14.99 '- 14.99 0 0 % 0 0 0 0 0 11 L�-GG _...__ IN '2g1azing..drIo*e___. 13AAccs ` 0.650 :_n,. 0.143 a _-,1820 4.00 ;.. _14.99 2.19 ------ 0.__ 0 _-0 0 0 0 ,.--G lN �C 2clazim. cir love.--__ -13A-4ocs -2 glazing cir lci e '2 glazing dr, bvr-e.. 13AAccs _.._..__0.650 0143 _ , 0650 ,_...__0650 0,143 e_ s s _ s., w -_„18.20 4.00 '18.20 ,__._18.20 4.00 .._._33.77 219 14.99 _, 14.99 2.19 -.._..__. . 0 0 0 . 0 0 _ ,......,___0 0 0 0 0 ._.._ 0 0 0 0 s..__--._0 0 0 0 _ _.__. .._ _..__._.. _ _...... 1w I-U C _.-16A30atl 2 glazing, cir 1- 2 glazln0. clr Im-e ....: 0.650 0650 .�0032 w w, -.. 18,20 18.20 0.90 33.77 33.77 22 `. 0 0 ._'24 0 0 . 24 0 _.. 0 , ._ 22q 0 .., 0 54 .. F._ -_ .22A-tPh._,1.358 ...-._ _ .. 38.02 ,_. 0.00 _ ... 24 _._ . -0-. , 0 ... ._ __0 ... ..._. �.._ .. _ _._ AED excursion 12 a) Infiltration 0 0 b) Room ventilation 0 0 13 Intemal gains: Occupants @ 230 0 0 Appliwceslother 300 Subtotal (lines 6 to 13) 22 349 Less eldemal load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 22 349 15 Duct loads 34% 59% 7 206 Total room load 29 I Air required (cfm) 1 1 25 .A � wrigh@soft' 201&Oct-02 08age 11 Right -Suite® Universal 2017 77.0.08 RSU08101 page 11 EADocumnelaMrighlsoft WAMCAUANDRO 3.mp Celc = MJ8 Front Door faces: S wrightsoft' Duct System Summary Entire House QUICK CALCS, INC. 317 Sr LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fa�c 772-466-6796 Email: OUICKCALCS@AOL.COM eL roject into For: CALIANDRO 3 MODEL, DAVE GOLDEN HOMES 18102 BRIDLE WAY, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1550 cfm Job: Dato: Oct 02, 2018 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1550 cfm 179 ft Supply Branch. Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Matt Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH c 1091 39 48 1.000 6.0 Ox0 VIFx 37.2 115.0 st2 BATH c 597 4 26 1.000 5.0 Ox0 VIFx 9.9 115.0 st3 BEDROOM 1 h 5058 219 126 1.000 7.0 Ox0 VIFx 42.7 115.0 st2 BEDROOM h 3565 155 112 1.000 7.0 Ox0 VIFx 44.9 115.0 st2 FOYER c 2516 92 111 1.000 7.0 Ox0 VIFx 14.6 115.0 st3 GREAT ROOM h 3861 167 145 1.000 6.0 0x0 VIFx 44.4 135.0 st4 GREAT ROOM -A h 3861 167 145 1.000 8.0 Ox0 VIFx 16.3 115.0 st3 KITCHEN c 2257 58 100 1.000 7.0 Ox0 VIFx 23.5 115.0 st1 KITCHEN -A C 2257 58 100 1.000 7.0 Ox0 VIFx 18.4 115.0 SO LAUNDRY h 3995 173 104 1.000 7.0 Ox0 VIFx 19.6 115.0 st1 LINEN C 672 6 30 1.000 5.0 Ox0 VIFx 17.7 115.0 SO •BATH h 2408 104 75 1.000 6.0 Ox0 VIFx 37.7 135.0 st4 M TOILET c 550 1 24 1.000 5.0 Ox0 VIFx 41.8 115.0 st2 MWIC c 523 8 23 1.000 5.0 Ox0 VIFx 39.9 135.0 st4 MASTER BEDROOM c 2588 109 115 1.000 7.0 Ox0 VIFx 42.8 135.0 st4 MASTER BEDROOM -A C 2588 109 115 1.000 7..0 Ox0 VIFx 39.6 135.0 st4 OFFICE c 2046 52 91 1.000 7.0 0x0 VIFx 13.6 115.0 st3 PANTRY c 556 1 25 1.000 5.0 Ox0 VIFx 16.4 115.0 st1 WIC c 791 25 35 1 1.000 5.0 OxO VIFx 1 42.7 1 115.0 st2 Wri htsoft° 2o18-oca0208:40:07 y9 Right -Suite® Universal 2017 17.0.08 RSW8101 Page 1 AM E:\Docu=els\Wrighlsoft WAC\CALIANDRO 3.mp Cato = MJ8 Front Door faces: S Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 439 345 1.000 805 10.0 0 x 0 VinlFlx st3 Peak AVF 813 847 1.000 792 • 14.0 0 x 0 VinlFlx st4 Peak AVF 498 473 1.000 755 11.0 0 x 0 VinlFlx st3 st1 Peak AVF 298 358 1.000 656 10.0 0 x 0 VinlFlx Return Branch Detail Table Name Grill Size (in) Htg (cfm) CIg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 1550 1550 0 0 0 0 Ox 0 VIFx wri htsOft 2018-Oc402 08:40:07 9 Right -Suite® Unlwrsal 2017 17.0.08 RSU08101 Page 2 ^`�"^ EADocunmels\Wrightsoft WAMCALIANDRO 3.rup Cato =MJ8 Front Door faces: S This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.