Loading...
HomeMy WebLinkAboutEVALUATION REPORTa.{ NEMO.1 etc. Certificate of Authorization #32455 �� 353 Christian Street, Unit #13 NI*:t3 Oxford, CT 06478 Si. LII SY (203) 262-9245' ENGINEER EVALUATE TEST rtCONSULT CERTIFY EVALUATIONREPORT Polyglass USA, Inc. Evaluation Report P12060.02.09-R24 1111 West"Newport, Center Drive FL5259-R28- Deerfield Beach, FL 33442 Date of issuances 02/24/2009 (954),233-1230 Revision 24:01/24/2018 SCOPE: This Evaluation Report is issued under Rule 61620.3- and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6"'' Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Polyglass RoofUnderlayments WEUNG:- Labeling shall be in. accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation'Report is valid until such time as the named product(s) changes, the referenced' Quality Assurance documentatiowchanges, or provisions ofthe 'Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s)i the Quality Assurance or the production facility location(s).. NEMOIetc, requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTisEMENT: The Evaluation Report number preceded by the words "NEMoletc. Evaluated" may be displayed- in advertising literature.: if any portion of the Evaluation 'Report, is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the .manufacturer or its distributors -and shall be available for inspection at the job siie.atthe request of the Building Official. This Evaluation Report consists of pages Ithrough 14. Prepared by: r S� RobertJ:M. Nieminen, P.E. Florida Registration No. 59166, Florida OC4 ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on ot/24/2DIS. This does not same as an electronhaily signed document. CERWICATION OF INDEPENDENCE: 1. NEW Ietc. does not have, nor does it Intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEW I etc. is not owneci,:operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does nothave nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financiallnterestin any other entity involved in the approval process of the product. 5. This is a building code,evaivation, Neither NEMOiett. nor, Robert Nieminen, P.E. are, in anyway, the"Designer of Record for any project on which thisEvaluationAeport, or; previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. "NEMO e I etc. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA; Inc., have demonstrated compliance with the following sections of the 6"' Edition (2017) Florida Building Code through testing in accordance with the following Standards.. Compliance Is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS:' Section property Standard Year 1504.31 Wind Uplift FM 4474 2011 1504.3A 'Wind Uplift UL 1897 2012 1507.2.3/,1507.1.1 Physical Properties ASTMD226 2009 1507.2.4 / 1507.1.1, 150719.2 Physical Properties ASTM D1970- 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 1507.11.2 Physical Properties ASTM 06164 2011 1507.11.2 Physical Properties ASTM 06222 2011 TA6110 Accelerated Weathering ASTM'D4798 2011 3. REFERENCES: Entity Examination; Reference- Date FM Approvals (TST1867).. Wind Uplift 3604091 01/12/2000 PRI (TST 5878) Physical` Properties. PRI01111 04108/2002 PRI (TST 5878) Physicals Properties. PUSA-005-02-01 01/31/2002 PRI (TST5878) Physical.Properties. PUSA-013-02-01 12/23/2002 PRI (TST 5878) Physlcal:Properties. PUSA-013-02-02 12/23/2002 PRI(TST S878) PhysicalProperties PUSA-013-02-03 12/23/2002 PRI (TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI (TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI (TST 5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI (TST 5878) Physical Properties PUSA-035.02-01 09/29/2006 PRI (TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI (TST Physical Properties PUSA-061.02.02 01/28/2008" PRI (TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRI (TST 5878) Physical Properties". PUSA-083-02.01 04/14/2008 PRI '(TST 5878) Physical. Properties, PUSA•088.02-01 07/29/2009 MTI"(TST•2508) Physical Properties JX201-17A 04/01/2008, MTI(TST 'MS) Physical Properties RX14E8A 01/29/2009 ERD (TST 6049) Physical Properties 11752.09.99.1 02/08/2000 ERD (TST 6049) Wind Uplift. 11757.08.'01.1 08/13/2001 ERD (TST 6049). Wind Uplift. 11776.06.02 01/16/2003 ERD (TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD (TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD (T5T6049) Physical :Properties P511OD4.07-1 04/11/2007 ERD (TST 6049) Wind Uplift :; P9260.03.08 03/21/2008 ERD (TST 6049) Physical Properties' P13450.08.09 08/13/2DD9 .ERD (TST 6049) Wind Uplift P30540.11.09-R1 11/30/2009 ERD (TST 6049)" Physical Properties P11030.11.09-1 11/30/2009 ERD (TST 6049) 'Wind Uplift P11030:11.09-2 11/30/2009 ERD (TST 6049)'. Physical Properties P11030.11.09-3 11/30/2009 ERD (TST 6049) Physical; Properties -P33360.06.10 06/25/2010 ERD (TST 6049) Physical Properties P33370.03.11 03/02/2011 ERD (TST 6049) Physical Properties P33310.04.11 04/2612011. ERD(TST 6049) Physical Properties P37300.10.11 10/19/2011 NEMO ETC, U.C. Evaluation.Repoq P12060.02:09-R24 CertffiwW gfAuthenrcfton #32455 6TM EDITION (2017) F8C"NON-HVHZ EVALUATION FI.5259-1128 PotWass Roof Underlayments; (954) 233-1230- Revision 24: 01/24/2019 Page 2of 14. 4. Entity ERD (TST 6049) ERD (TST 6049): ERD (TST 6049), ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6a49) ERD (TST 6049) ERD (TST 6046). ERD (TST'6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049). ERD(TST ERD (TST 6049) ERD (TST 6049); ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) -ERD '(TST 6049) ERD (TST 6049) ERD ;(TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD(TST6049) ICC-ES (EVIL 2396) Miami-Dade:(CER 1592) Polyglass USA. Polyglass USA Polyglass USA. UL, LLC.(QUA9625) PRODUCT DESCRIPTION. Examination. Physical Properties Physical Properties Physical Properties' Wind Uplift Physical Properties Wind Uplift Wind Uplift. Wind Uplift Wind Uplift Wind Uplift Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties. PhysicalProperties Physical' Properties. Physical Properties Physical Properties Physical Properties Wind Uplift Physical Properties Wind Uplift Physical Properties Physical Properties, Physical Properties 16C Compliance_ HVHZCompliante Manufacturing Affidavit P/L Affidavit MaterialsAffidavit Quality Control Reference P40390.08.12-1 P46390.08112 2 C41420.09.12.3 P39680.03.13 P45370.04.13. P1738.02.07-R2. 31757.04.01=1-.RS P41630.08.13 011751.05.03-R1 P11781.11.03-R1 P45270.05A4, 6020,07,14-1 -6020.09.14-2 6020.09:14-3 6020.09.14-4 6020.09,14-5 6020.09,14-6 046520.10.14 P43290.10.14 PLYG-SC7550.03,15 P40390.04,15. P44360.1014-R1 PLYG-SC8080.05.15-5 PLYG-SC8905.05.16-1 PLYG-SC808007.16 PLYG-SC12025.10.16, PLYG-SC13040.12.16 PLYGSC11900.03.17 PLYG-SC12115.08.17 ESR-1697 NOA 14-0717.08. Products Current Mule -Hide Crossltg Polystick:SA Compound Service Confirmation 41.2 Elastobase P is a polyester -reinforced, SB$ modified,bitumen base sheet, 4.1.3 Polyglass G2 Base Is a fiberglass -reinforced, asphaltic base. sheet. 4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet. ONEMOletc. Date 08/06/2012 08/07/2012 09/11/2012 03/04/2013 04/26/2013 04/29/2013 04130/2013' 08/06/2013 11/26/2013 11/26/2013. 05/12/2014 09/08/2014 09/08/2014 09/08/2014 09/08/2014 09/08/2014 09/08/2014 10/03/2014 /0/1712014 . 03/2412015 04/03/2015 05/18/2015 05/20/2015 05/17/2016 07/16/2016 10/12/2016 12/21/2016 03/10/2017 O8/08/2017 11/0112014 01/22/2015 02/18/2009 03/02/2008 OS/18/2011 Exp.10/05/2018 4.2.1 Polystick MTS or Polystick MTS PUTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with polyoiefinic film surface; meets FRSA/TRI April2012. 4.3.2 Polystick IR-Xe Is a nominal 60-mil thick rubberized, asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM'D1970. 4.2 3 Polystkk TU Plus is a:nominalSO-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets A5TM D1970 and,FRSA/TRI April 2012, NEMO:ETC; LLC. Evaluation Report P12060.02.09-R24 Certtj/cate afAuth vhatton #32455 :e EDITION (2017) FOC NON•HVHZ EVALUATION FL5259-RZB Polyglass Roof Underlayments; (954) 233.1230 Revision 24:.01/24/2018: Page 3 of 14 ft-V 0'�NEMOjetc. 5.5 Allowable Roof Covers: Underlayment Asphaft Shingles 29, ..: 'Nail -on Tile Foam-On;Tile - Metal Wood Shakes &Shingles state Elastobase Yes Yes (Rase sheet in 2-ply system)Fl�esheet Yes In 2-piysvnem)Elastobase Yes Yes yes _ P Yes Yes (Basesheatm2 lysystemshentinz-PI Yes. system) yes Yes Yes Polyglass G2 Base No Yes (ease Sheeting iysynem) Yes (ame Sheet in 2-piy systeml No. No No Polyglass APP Base _._._�. No Yes " (Rase sheet in 2NNsysxm) yes iDase:Sheet lnx.piv:ysteml. No No No Polystick MTS or MIS PLUS Yes Yes No Yes Yes Yes Polystick IR-Xe Yes No No No Yes Yes Polystick TU P No, Yes Yes (See 5:5:1) No No No Polystick TU Plus Ves Yes Yes (See 5.5,1) _ Yes Yes Yes P6lystickTUMax No Yes Yes (SeeSS.1) Yes No No Po�_Dual al Pro yes No N6' Yes Yes Yes PoiystiikTile Pro Yes Yes Yes. (SeeS:5.1). Yes :Yes Yes Polystick MU-X m Yes No No Yes Yes Yes , ElastMlex S6.G � Yes 'Yes Yes (5ee5.6.) No - Yes Yes Elastollex 56`G FR 'Yes ,Yes No No Yes Yes ElastoBex GTU Yes - Yes. Yes, (5ee5S.1)`_ No. Yes Yes PolyneX6 Yes. Yes Yes (See5.5Si) No Yes Yes Polyflex GFR'. eyes Yes No No Yes- 'yes ' PolynexSAP arSAP FR Yes Yes Yes (see 5S:1) No Yes _ yes Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (Fit) Yes Yes' Yes (See5:5.1) - No Yes Yes 5-.5.1 "Foam -On Tile Is limited to use of the following Approved, the adhesives / underlaymentcombinations'. 7R, q` ARSi�w/,Y.AEtt- L��ti?a'SMSA:/llP.e.v�i'6 �Aw f. '+iiy„f+'A;ial w "k t'.try uan��V Gi .,5'W. Adhesive Florida Product Underlayments .. Approval DAP Foam Touch 'nSeal 5tormilond Roof FL14506 PolystickTU Plus,.PolystickTU Max Tile Adhesive Dow TileBond"' FL22525 PolystickTU P, Polystick TU Plus, Polyflex'SAP.or Tile Pro PolystickTU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, ICP Adhesives.Polyset° AH-160 FL6332 ' Elastoilex G TU, Elastoftex.S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, `I 'Mule -Hide SA-APP-Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) PolystickTU P; Polystick TU Pius, Polystick TU Max, Polystick Tile Pro, ICP Adhesives Polyset° RTA-1. F1.62% Elastoflex G TU, ElastoflexS6 6, Polyflex G, Polyflex SAP,.Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet I t Refer to Tile Manufacturer's or Adhesive Manufacturer's;Horldo, Product Approval jar Overturning: Moment Resistance Performance. MEMO ETC, LLC:. Evaluation Report P12060.02.09-1124 Cernf/mte:ofAuthutizat)en#32455 6"EDITIONJ2.017)FBCNON-14VH2.EVALUATION .FLS259-R28 Potyglass Roof Underlayments; (9S4) 233-2230 Revision 24: 01/24/2018 Page 5 of 14 ONEMOjetc. Allowable Substrates: 5.6.1 Qirect-Bond to Deck:. Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: P New'untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing plywood New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods 'ZIP System" Panels (designed and installed to meet wind loads for project).. Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywoodor OSB sheathing should -be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex GTU; Elastoflex S6 G or Elastoflex S6'G FR in hot asphalt to: ➢ ASTM D41 primed' structural concrete. Polyflex G or Polyflex G FR.torch-applied to: A ASTM D41 primed, structural concrete. 5.6:2 Bond-to-lnsulatlon: Polystick (ail variations), Polyflex SAP or -SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ ASTM C1289, Type R, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard;.Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G' FR in hot asphalt to: Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. Polyflex G or PolyflexG FR torch -applied to: D ASTM D41 primed structural concrete;. Dens Deck Prime or, SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof' coverings, insulation shall' be attached per minimum. requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems; insulation attachment shag be designed by a qualified design professional and installed based on testing of the insulation/underlaymentsystem in accordance with,FBC'Section 1504.3.1. 5,63 Bond to Mechanically Attached Base (:aver: Polystick (ail variations), Polyflex SAP or SAP FIR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: ➢ ASTM D226, Type I or 11 felt; Elastobase; Elastobase P or Mule -Hide Nail Base. Elastoflex G TU, Elastoflex 56'G or Elastoflex S6 G FR'irrhot'asphalt to: D ASTM D226, Type for If felt; Elastobase;`Elastobase'P, Mule -Hide Nail'Baseor Polyglass G2 Base. Polyflex G or Polyflex G FR torch -applied for Elastobase; 'Elastobase 'P, Mule -Hide Nail Base, Polyglass G2'Base or Polyglass APP Base. For installations under mechanically attached prepared roof coverings; base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSAjTRI Apri12012'(04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC Section 1504.3.1. NENIO ETA, L1C Evaleatlun Report P12060.02.09-R24 Cert✓6cate pfAuthprhutlan 032455 6'-a EDITION(2017i Pat NON-HVH2 EVALUATION Fl5259-R28: 'Potyglass Roof Underiayments; (954) 233-12M Revision24: 01/24/2018 Page 6 of 14 CP EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 � �� M1CC 353 CHR15TIAN STREET, UNIT#13 GR� SCANNx® OXFORD, Ci 06478 BY (203) 262-9245 EVALUATION REPORT TRI-BUILT Materials Group, LLC ,,uunlyEvaluation Report A42960.10.12-116 PO Box,70 FL16048-R6 Rutherford, NJ 07070 Date of Issuance:10/25/2012 (800) 516-1485 Revision 6: 09/25/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the Ste Edition (2017) Florida Building Code section's noted herein. DESCRIPTION: TRI-BUILT Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality'Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity) ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authored by Robert Nleminen, P.E. on 09/25/2017. This does net serve as on Mactranloll, signed document. CERTIFICATION OF INDEPENDENCE: 1. Trintyl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity Involved in the approval process of the product. S. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P:E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. r � TRINITY � Eaa ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have demonstrated compliance with the following sections of the 6`h Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Resistance FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1504.6 Accelerated Weathering ASTM G155 2005 1507.2.4 / 1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 (04-12) 2012 3. REFERENCES: iniitlf Examination Reference Date ERD (TST6049) Physical Properties S40540.02.13-1 02/19/2013 ERD (TST6049) Physical Properties S40540.11.13 11/19/2013 ERD (TST6049) Physical Properties S40540.03.14 03/26/2014 ERD (TST6049) Physical Properties S44870.04.14-2 04/02/2014 ERD (TST6049) Physical Properties S44870.04.14-3 04/02/2014 ERD (TST6049) Physical Properties S44870.04.14-1 04/10/2014 ERD (TST6049) Physical Properties S44870.04.14-4 04/10/2014 ERD (TST6049) Physical Properties S43530.02.14-1-R1 05/14/2014 ERD (TST6049) Physical Properties S43530.05.14 05/28/2014 ERD (TST6049) Physical Properties S40540.10.14 10/31/2014 ERD (TST6049) Physical Properties SC7645.02.15 02/13/2015 ERD (TST6049) Accelerated Weathering SC8520.04.15 05/27/2015 ERD (TST6049) Wind Resistance SC14045.05.17-R1 06/07/2017 UL, U.C. (QUA9625) Quality Control Multiple -Listing R16814 12/10/2015 UL, LLC. (QUA9625) Quality Control Service Confirmation Exp. 07/18/2020 4. PRODUCT DESCRIPTION: 4.1 Tri-Built Sand-R SA Shingle Underlayment is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment, with a 36-inch sheet width; meets ASTM D3970. 4.2 Tri-Built S/A HT TU Underlayment is a self -adhering, non -woven polyester fabric surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012. 4.3 Tri-Built Smooth HT S/A Underlayment is a self -adhering, glass -mat reinforced, film -surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, I.I.C. Evaluation Report A42960.10.12-R6 CCrtf%lcate of Authorization 09503 6'" EDITION(2017) FBC NON-HVHZ EVALUATION FL16046-R6 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 2 of 6 `.1 1 KINIlY ERD 5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONSy - • - L-�` Underlayment Asphalt Nail -On Tile Foam -On Tile Metal Wood Shakes Slate Shingles & Shingles Tri-Built Sand-R SA Shingle Underlayment Yes No No No Yes Yes Tri-Built S/A HT TU Yes Underlayment Yes Yes See 5.5.1 Yes Yes Yes Tri-Built Smooth HT S/A Underlayment yes No No Yes Yes Yes 5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. TABLE-1A: ALLOWABLE TILE ADHESIVE/ UNDENULYNiENT ComBINATIDN51 Adhesive' Florida Product Approval Underlayments ICP Adhesives Polyset® AH-160 FL6332 Tri-Built S/AHTTU Underlayment Dow TileBond'" FL22525 Tri-Built S/A HT TU Underlayment 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete. While not required over plywood, 0513 or Southern Yellow Pine substrates, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI-BUILT Materials Group, LLC requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -adhering underlayment. 5:6.2 Bond -to -Insulation: Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474, Appendix D or TAS 114, Appendix J. ' Refer to Tile Manufacturer's or Adhesive Manufacturers Florida Product Approval for Overturning Moment Resistance Performance. Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6 Certii lcate of Authorization #9503 6'" EDrnoN (2027) FBC NON-HVHZ EVALUATION FL16048-1116 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 3 of 6 1 TRINITY I ERD 5.6.3 Bond to Mechanically Attached Base Laver: Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ ASTM D226, Type I or II felt. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems (Tri-Built S/A HT TU Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04- 12). 5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind pressures. #1 Maximum Design Pressure = -45.0 Dsf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 or RESISTO EXTERIOR PRIMER Underlayment: Tri-Built S/A HTTU Underlayment, self -adhered. #2 Maximum Design Pressure = -67.5 Dsf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Soprema Elastocol 600c Underlayment: Tri-Built S/A HTTU Underlayment, self -adhered. #3 Maximum Design Pressure = -150.0 DO Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional) RESISTO EXTERIOR PRIMER Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids, and ensure there are no voids/bridging at side and end -laps. #4 Maximum Design Pressure=-60.0 Dsf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three, equally spaced rows in the center of the sheet. Underlayment: Tri-BuiltS/A HT TU Underlayment, self -adhered. Exterior Research and Design, U.C. Evaluation Report A42960.10.1Z-116 Certificate of Authorization#9503 eEDITION (2017)FBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6:09/25/2017 Page 4 of 6 I Q-TRINITY ERb, 5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 3A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left exposed for longer than 30-days after installation Tri-Built S/A HTTU Underlayment shall not be left exposed for longer than 180-days after installation. 5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-121): When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2i TILESUPPAGE LIMITATIONS FOR DIRECT-DECKTILE INSTALtATION5' Underlayment Tile Profile Staging Method Maximum Slope Flat Max. 10-tile stack 6:12 Lugged Max. 10-tile stack 5:12 Max. 10-tile stack (bottom 2-tile stack shall be inverted, followed by 8 tiles high 6:12 on slope, as shown below) Tri-Built S/A HT TO Underlayment Lugged `ue E Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6 Certificate of Authorization N9503 6'"EDITION (2017)FBC NON-HVHZ EVALUATION F1.16048-116 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 5 of 6 \4 I KINTY ERD 6. INSTALLATION: 6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.3.2 Non -Tile applications: While priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 fit of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel -off the release film diagonally while holding the membrane tight. Firmly roll, broom or hand -press the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below, sealed in accordance with TRI-BUILT Materials Group, LLC requirements. When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back -nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys, apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications (Tri-Built S/A HTTU Underlayment only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012 (04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile staging. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. S. MANUFACTURING PLANTS: Gulfport, MS 9. QUALITY ASSURANCE ENTITY: UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6 Certi/)cate o/Authorization #9503 a EDITION (2017) FBC NON-HVHZ EVALUATION F1.16048-116 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 6 of 6