FLORIDA ENERGY EFFICIENCY CODE .FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE STERLING
Builder Name: WYNNE DEVELOPMENT
Street: THE STERLING
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner: 1 LJ (�9
Jurisdiction:
Design Location: FL, Fo Pierce
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types(1442.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1250.00 ft2
b. Frame - Wood, Adjacent
R=11.0 192.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
10. Ceiling Types (1474.0 sgft.)
Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1474.00 ft2
6. Conditioned floor area above grade (ft2) 1474
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(141.3 sgft.) Description Area
a. Sup: Attic, Rat: Attic, AH: Attic
6 300
a. U-Factor: Sgl, U=0.63 101.25 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.65 40.00 ft2
12. Cooling systems 00,
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit st ^
34.8 SEER:15.00
c U-FactN/A ft2
O'V'VL
�4 `okBtu/hr
SHGC:
13. Heating systems 0
Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump 0%
34.8 HSPF:8.50
SHGC:
l�
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.239
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1473.5 sqft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.096 Total Proposed Modified Loads: 48.34
PASS
Total Baseline
Loads: 48.53
1 hereby certify that the plans and specifications covered by
Review of the plans and
4g8E STgl
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
<ri .,
y a„ _ `s
with the Florida Energy Code.
1~ '-A -
PREPARP B
Before construction is completed
DATE: "�")
this building will be inspected for
O a
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
COB WS S¢�
OWNERK "N
BUILDING OFFICIAL:
DATE: 11
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 Fy
Ce
tnoPY
4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
PROJECT
Title: WYNNE THE STERLING Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1474
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180
Street:
THE STERLING
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1474 11792
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM
329 2632 No
0
1
1 Yes
Yes
Yes
2 WIC
63 604 No
0
1 No
Yes
Yes
3 M. BATH
56 448 No
0
1 Yes
Yes
Yes
4 KITCHEN
192 1536 Yes
0
1 No
Yes
Yes
5 BATH
45 360 No
0
1 Yes
Yes
Yes
6 BEDROOM 2
204 1632 No
0
1
1 Yes
Yes
Yes
7 ENTRY
55 440 No
0
1 Yes
Yes
Yes
8 LAUNDRY
42 336 No
0
1 Yes
Yes
Yes
9 GREAT/DINING
488 3904 No
0
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 52 ft 0
329 ft2
-_-_
0 1
0
2SIab-On-Grade Edge Insulatio
WIC 1 ft 0
63 ft2
_-
0 1
0
3SIab-On-Grade Edge Insulatio
M. BATH 8 ft 0
56 ft2
___
0 1
0
4SIab-On-Grade Edge Insulatio
KITCHEN 1 ft 0
192 ft'
____
0 1
0
5 Slab -On -Grade Edge Insulatio
BATH 5 ft 0
45 ft2
___
0 1
0
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 32.2 ft 0
203.5 ft2
____
0 1
0
7 Slab -On -Grade Edge Insulatio
ENTRY 7 ft 0
55 ft2
__--
0 1
0
4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
0
42 ft'
____
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0
488 ft'
_-
0
1
0
ROOF
_ / Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V # Type Materials Area
Area
Color
Absor. Tested
Tested
insul.
(deg)
1 Gable or Shed Metal 1553 ft'
246 ft'
Light
0.6
No
0.9
No
0
18.4
ATTIC
/
V # Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1474 ft'
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
329 ft'
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft'
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft'
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 fP
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft'
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft'
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft'
0.1
Wood
9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ft'
0.1
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing
Solar
Below
RA/ah
Is Pt In
Ft
In
Area
R-X/nhip Frgotion
Ahqnr
0
1 NE=>SW Exterior Concrete Block - Ext Ins(BEDROOM
4.1 10
0 8
0
80.0 ft'
0
0
0.6
0
2 SW=>NE Exterior Concrete Block - Ext Ins(BEDROOM
4.1 28
0 8
0
224.0 ft'
0
0
0.6
0
3 NW=>SE Exterior Concrete Block - Ext Ins(BEDROOM
4.1 14
0 8
0
112.0 ft'
0
0
6.6
0
_ 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH
4.1 6
0 8
0
64.0 ft'
0
0
0.6
0
5 NE=>SW Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft'
0
0
0.6
0
6 NE=>SW Exterior Concrete Block - Ext InRIEDROOM 2
4.1 16
0 8
0
128.0 ft'
0
0
0.6
0
7 SE=>NW Exterior Concrete Block - Ext Infi EDR00M 2
4.1 10
0 8
0
80.0 ft'
0
0
0.6
0
8 S=>N .Exterior Concrete Block - Ext InfilEDROOM 2
4.1 4
3 8
0
34.0 ft'
0
0
0.6
0
9 SW=>NE Exterior Concrete Block- Ext InBEDROOM 2
4.1 2
0 8
0
16.0 ft'
0
0
0.6
0
10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY
4.1 6
0 8
0
48.0 ft'
0
0
0.6
0
11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY
4.1 1
0 8
0
8.0 ft'
0
0
0.6
0
_12 SW=>NE'Exterior Concrete Block - Ext InsdIAUNDRY
4.1 6
0 8
0
48.0 ft'
0
0
0.6
0
_13 NE=>SW Exterior Concrete Block -Ext In98REAT/DINI
4.1 26
0 8
0
208.0 ft'
0
0
0.6
0
_14 NW=>SE Exterior Concrete Block- Ext InaREAT/DINI
4.1 20
0 8
0
160.0 ft'
0
0
0.6
0
15 N=>S Garage Frame - Wood KITCHEN
11 24
8
192.0 ft'
0.23
0.6
0
4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
FARM R405-2017
DOORS
# Ornt
Door Type Space
Storms U-Value Width
Ft In
Height
Ft In
Area
1 SE=>NW
Insulated ENTRY
None .39 3 1
6 8
20.6 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
V # Ornt ID Frame
Panes NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1 NW=>SE 3 Metal
_ 2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW13 Metal
5 NW=>SE14 Metal
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
0.63 0.25 N 32.9 ft2 1 ft 0 in 1 ft 4 in
0.63 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in
0.63 0.25 N 24.0 ft2 6 ft 0 in 1 ft 4 in
0.63 0.25 N 37.5 ft2 1 ft 0 in 1 ft 4 in
0.65 0.21 N 40.0 ft2 8 ft 0 in 1 ft 4 in
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315ft2
315ft2
24ft 8ft
11
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1375.7 75.53 142.04 .2598
7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/ Split
HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unitt
Split
SEER: 15 34.8 kBtu/hr cfm
0.85 1
sys#1
HOT WATER SYSTEM
# System Type
SubTpe Location
EF Cap Use SetPnt
Conservation
1 Electric
None Garage
0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume FEF
None None
ft2
4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017
DUCTS
/
— Supply
—
— Return —
Air
CFM 25
CFM25
HVAC #
V #
Location R-Value
Area
Location
Area
Leakage
Type
Handler
TOT
OUT
ON
RLF
Heat Cool
1
Attic 6
300 ft'
Attic
75 ft'
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programabl[e
Y
C[ei]ling Fans:
Heating [X]
]Thermostarrt:
Jan [X� Feb
Mar
[
[
]
] AApi' [
]May
Jun
rX�
[ ]Jul
[X]
[ ]Aug
[ ]
Sep
v
�[r[XX]]
Dec
Venting II
11 Jan II[ 11 Feb
X Mar
[X)
[
]
lXl Jun
I 1 Jul
[ ] Aug
EX]
] Sep
Oct
lxl Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (VVD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 5
A2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT
Street: THE STERLING Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceilinglattic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in an ceiling/soffit
Y dropped soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
air
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
Bs.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind pip'no and wirino
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
„ „F�L UL.,, . I ,„s wdna anon ue if du:uwdnae wim me provisions or ruw-4uu.
4/17/2018 2:38 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (W)
7. Windows" Description
a. U-Factor: Sgl, U=0.63
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.65
SHGC: SHGC=0.21
c. U-Factor: N/A
SHGC:
d. U-Factor. N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
THE STERLING, FT. PIERCE, FL,
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1250.00 ft
b. Frame - Wood, Adjacent
R=11.0
192.00 ft
1
c. WA
R=
ft2
2
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
Yes
a. Under Attic (Vented)
R=30.0
1474.00 ft2
1474
b. N/A
R=
ft2
Area
c. N/A
R=
ft2
101.25 ft=
11. Ducts
R ft'
a. Sup: Attic, Ret: Attic, AH: Attic
6 300
40.00 ft'
12. Cooling systems
kBtu/hr
Efficiency
ft2
a. Central Unit
34.8
SEER:15.00
ft'
13. Heating systems
kBtu/hr
Efficiency
a. Electric Heat Pump
34.8
HSPF:8.50
3.832 ft.
0.239
Insulation Area
R=0.0 1473.50 ft2
R= ft2
R= ft'
14. Hot water systems
a. Electric Cap: 40 gallons
EF: 0.97
b. Conservation features
None
15. Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features. \\
Builder Signature: Date: �� \7\ls�
Address of New Home: Zj C�q`rj City/FL Zipt�
L" -� 5�
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
h
�# wrightsoftProject Summary
Entire House
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-46"796 Email:
For. WYNNE DEVELOPMENT
THE CA\RLTOON r. /299, FPIEERC-E,FFIL
Notes: `,A
Desi n Information
Weather. Fort Pierce, FL, US
Winter Design Conditions.
Outside db 42 OF
Inside db. 70, OF
Design TD 26 `F
Heating Summary
Structure 18188 Btuh
Ducts 5664 Btuh
Central vent (0 cfm) 0 Btuh
(none)
Humidification 0 Btuh
Piping. 0 Btuh
Equipment load 23842 Btuh
Infiltration
Method Simplified
Construction quality Average
Fireplaces 0
Area ft z
He 1474
Cc 1474
Volume
1
10
Air changeesrhour
0�.45
3 22
Equiv.AVF (cfm)
92
47
Heating Equipment Summary
Make Carrier
Trade CARRIER AIR CONDITIONING
Model 25HBC536A`030
AHRI ref 7914585
Efficiency
Heating input
Heating output
Temperature rise
Actual'air flow
Air flow factor
Static pressure
Space thermostat
Capacity balance point = 33 OF
8.5 HSPF
34600
Btuh @ 47OF
27
0
1160
cfm
0.049
cfm/Btuh
0.50
in H2O
Backup:
Input = 7 kW Output = 23009 Btuh, 100 AFUE
Job:
Date:
By:
SCq
SS
t 4UciCpuO.
n�,
Summer Design Conditions
Outside db
90'
OF
Inside db
75
OF
Design TD
15
`F
Daily range
L
Relative humidity
50
%
Moisture difference
61
gdlb
Sensible Cooling Equipment Load Sizing
Structure
17877
Btuh
Ducts
8536
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Blower
0
Btuh
Use manufacturer's data
n
Rate/swing multiplier
Equipment sensible load
0.95
25093
Btuh
Latent Cooling Equipment
Load Sizing
Structure
2958
Btuh
Ducts
2319
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Equipment latent load
5277
Btuh
Equipment total load
30370
Btuh
Req. total capacity at 0.70 SHR
3.0
ton
Cooling Equipment Summary
Make Carder
Trade CARRIER AIR CONDITIONING
Cond 25HBC536A'030
Coil FX4DN(B,F)037
AHRI ref 7914585
Efficiency 12.0 EER, 15 SEER
Sensible cooling
24360
Btuh
Latent cooling
10440
Btuh
Total cooling
34800
Btuh
Actualair flow
1160
cfm
Air flow factor
0.044
cfm/Btuh
Static pressure
0.50
in H2O
Load sensible heat ratio
0.83
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-t# blrrightrsoft• Right-Sune® Unlwmai 2Ol7 r7.a14 RSU681g1 2o17-Apr-m 17:14:53
' � ...Wrightson WAOMM E-THE GRAND CARLTCN-299.rup Cola = MJ6 Front Door faces: N Page 1
.wrightsoft• Right-JOWorksheet Job:
Entire House Date:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Emit: OUICKCALCS ,AOLCOM
1
Room name
Entire House
BEDROOM
2
5ywsed wall
156.2 ft
62.0 ft
3
Room height
8.3 it d
8.0 ft heaticool
4
Room dimensions
1.0 x 329.0 It
5
Room area
1473.5 iP
329.0 ft'
Ty
Construction
U-value
Or
HTM
Area (ft-)
Load
Area (ftj
Load
number
(BtuWftuF)
(Btuhlit j
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
WPIS
Heat
Cool
Gross
WPJS
Heat
Cool
6
W�
13A4ocs
0.143
. ne
.4.00
2.55
479
442
1768
1124
80
.80
320
- 204
LG:
';1Abtom
1.270
ne
35.56
70.43
38
0
1344
2662'
`. 0
0
'- :0
.-` 0
4)I
13A-4ms
0.143
se
4.00
255
128
83
331
210
0
0
0
0
hL-(D'
1Ac1om
1.270
se
35.56
34.77
24
48
848
829
0
0
0
0
11
11DO
0.390
se
10.92
11.31
22
22
236
244
0
0
0
0
W '
43A4ocs
0.143;
a
4:00
255
34
34
- 136
.86
0'
..0
' 0
0
t-�
13AA=
0.143
sw
4.00
265
360
353
1414
899
224
224
897
670
1Aatom
1270
sw
3556
42.91
7
11
247
298
0
0
0
0
13A4ocs
:.0.143
nw.
4.00
` 2.55
290
217
867
. 551
112
79.
- 318
- 202
1Ao1om
t270
nw
3566.
45.24
33
.0
-1162
1478.
33..
'0
` 1162
i ., 1478
-P
4A6-2orn
0.77o
tnw
26
t5
.'27.54
41
0:
880
1124"
.0
0..
0
.•0
12C.0sw
0.091
-
2.55
1.28
192
192
489
246
0
0
0
0
C
16A-30md
0.032
-
0.90
232
1474
1474
1320
3419
329
329
295
763
F
22 -tpl
0.989
-
27.69
0.00
1474
156
4325
0
329
52
1440
0
6
c)AED excursion
784
680
Envelope loss/gain
15M
13954
4432
3897
12
a) Infiltration
2822
773
909
249
b) Room ventilation
0
0
0
0
13
internal gains: Occupants@ 230
5
1150
2
460
Applianceslother
20M
0
Subtotal Dines 6 to 13)
18189
17877
5341
4606
Less eldemal load
0
0
0
0
Less transfer0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
18188
1.77
5340
4606
15
Duct loads
31%
48%
5654
8536
31%
48%
1660
2199
Total room load
23842
21413
7001
6805
Air required (cfm)
1160
1160
341
299
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed
�CZ`h Tb'r wrightsoft• RlghlSuite@ Universal 201717.0.14 RSUD8101 2017-Apr-1017:14:53
...Wdghtsoft WAC1WYNNE-THE GRAND CARLTON-299.mp Calc=MJ8 Front Door faces: N Page
+ wrightsoftRight-M) Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By:
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: OUICKCALCS@AOLCOM
1
Room name
WIC
M. BATH
2
Eaqaosed wall
0 ft
8.0 It
3
Room height
8.0 ft heat/cool
8.0 ft heallcool
4
Room dimensions
7.0 x 9.0 It
7.0 x 8.0 ft
5
Room anew
63.0 ft'
56.0 ft'
TY
Construction
U-value
Or
HTM
Am (ftj
Load
Area (fly
Load
number
(Btu1Vf(MF)
(BtUh/fF)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
WP/S
Heat
Cool
Gross
WPIS
Heat
Cool
6
W
13AA=
0.143'
no
4.06
255
• -0
0
0
.0
0
0
0
0
L-G-
JActan
1.270
-:ne<.
-35.56
..70.43:.
.0
0
.. 0
•0
0.
0
:0
. -'0
4�l!-�`
13A4ocs
0.143
se
4.00
2.55
0
0
0
0
0
0
0
0
IA-clown1.270
se
35.56
34.77
0
0
0
0
0
0
0
0
11
`D
11DO
0.390
se
10.92
11.31
0
0
0
0
0
0
0
0
W
13A-0acs
0.143
s
4.00
2.65
0
•0
0
0
0
0
()
I ' 0
W
13A4o s
0.143
sw
4.00
255
0
0
0
0
64
57
228
145
1Aclon _
1270
sw
35.56
42.91
0
0
0
0
7
5
247
298
1.11f-
13A-4ocs
.0143
hw
400
' 2.55
0
0
0
0
l>
.0
0
- '- 0
-1A=clom
-1270
rov
35:56
45:24
0.
-0•
0
0
0-.
..p;-
0
0
4A.5-2om' .
"0.770
nw
21.56
27.54
0
0
' 0
'0
0
0
0
' - 0
P
12C-0sw
0.091
-
2.55
1.28
0
0
0
0
0
0
0
0
C
16A30md
0.032
•
0.90
Z32
63
63
56
146
56
66
60
130
F
22A-tot
0.989
-
27.69
0.00
63
0
0
0
56
8
222
0
8
c)AFJO excursion
-2
225
Envelope losslgain
66
145
747
798
12
a) Infiltration
0
0
140
38
b) Room ven ilatim
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal Qirles 6 to 13)
56
145
887
gib
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
14
Subtotal
55
145
887
836
15
Duct loads
31%
48%
18
69
31%
480/6
276
399
al md lead
'4
219
1167
1235
AToirt)
54
Calculations approved byACCA to meet all requirements of Manual J 8th Ed
A wrightsoft• Right -Suite® Universal 201717.0.14 RSU08101 2017-Apr-1017:14:53
...Wdghlsoft WtlACIWYNNE-THE GRAND CARLTON-299.mp Cale = MJ8 Front poor faces: N Page 2
+ wrightsoft• Right+J® Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-46"796 Emil: QUICKCALCS@AOL.COM
1
Room name
KITCHEN
BqH
2
Emposed wall
0 ft
5.0 ft
3
Room height
&0 ft heat/cool
8.0 It heat/cool
4
Room dimensions
1.0 x 192.0 ft
9.0 x 5.0 ft
5
Room area
1920 ft°
45.0 ft-
Ty
construction
U-value
Or
HTM
Area (ft2)
Load
Area
Load
number
(RUWRx°F)
(BtUWfN)
or perimeter (ft)
(Ruh)
or perimeter (ft)
(Ruh)
Heat
Cool
Gross
WP/S
Heat
Cool
Gross
WP/S
Heat
Cool
6
W �
'13A4ocs'
0.143
ne
- 4.00
. 2.55
0
0
- 0
0
40
40
160
�102
LG
1Actonn
1.270
ne
35.66
70.43
0'
-0
0-
0
-0
0:
,0
WI-G
13AAccs
0.143
se
4.00
2.55
0
0
0
0
0
0
0
0
1Aclom
1.270
se
35.56
34.77
0
0
0
0
0
0
0
0
11DO
'.13AAocs
0.390
se
10.92
11.31
0
0
0
0
0
0
0
0
w
0.143:
a
.4.00
255
0
0
- 0
-. 0
0
0
.0
0
W
Y-G
IaA4ocs
0.143
sw
4.00
2.55
0
0
0
0
0
0
0
0
1Aclom
1.270
sw
3556
4291
0
0
0
0
0
0
0
0
13A-4ocs
0:143
nw
4 00
2.55
0
" 0
- 0
- :0
:' 0
: • 0
. .0
' � ' 0
1Ac1om.
1.270
, my
35 56
i 7 45.24
:0
- 0
, 0
- - 0
- , .a
' +0
. ' 0
- -; 0
.0.770
nw,
21.56
- -27.54
0
0
" 0
0
0
0
- 0
.= "0
P
12COsw
0.091
-
2.65
1.28
64
64
163
82
0
0
0
0
C
16A-30md
0.032-
0.90
2.32
192
192
172
445
45
45,
40
104
F
22A-tpl
0.989
-
27.69
0.00
192
0
0
0
45
5
138
0
6
c)AED excursion
-27
-p
Envelope loss/gain
335
501
339
204
12
a) Infiltration
0
0
87
24
b) Room ventilation
0
0
0
0
13
Irtemal gains: Occupants @ 230
0
0
0
0
Appliances/other
2000
0
Subtotal Qines 6 to 13)
335
2501
426
228
Less ademal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
335
2501
426
15
Duct loads
31%
48%
104
1194
31%
48%
133
109
109
Tatal room load
439
3695
559
336
Alr required (cfm)
21
162
27
15
�4� Calculations approved byACCA to meet all requirements of Manual J 8th Ed
.A -'7� wrightsoR• RlghtSulte® Universal 2017 17.0.74 RSUD8101 2017-Apr-1017:14:53
...Wnghtsoft FNAC1WYMJE-71iE GRAND CARLTersal2 17 Cale=MJB SUD Front Daor faces: N
Page 3
wrightsoft• RighWO Worksheet Job:
Entire House Date:
By:
QUICK CALCS, INC.
317 ST. LUCIE I-M, FT. PIERCE, FL 34946 Phone: 772-466-6799 Fa c 772466-6796 Email: QUICKCALCS@AOL.COM
1
Room name
BEDROOM
ENTRY
2
Egased wall
32.2 It
7.0 ft
3
Room height
8.0 R heattcool
8.0 R heat/cool
4
Room dimensions
1.0 x 203.5 If
1.0 x 65.0 It
5
Room area
203.5 ft-
55.0 ft-
Ty
Construction
Or
AM er
Load
Am
Load
u bere
number
(Btuh/fMF)
(Btuwftl)
or perimetHTM
(ft)
(BlW)
or Perimeter (ft)
(Btuh)
Heat
Cool
Gross
WP/S
Heat
Cool
Gross
WP/S.
Heat
Cool
- 6
y1 �
,13A-4ms
"0.143
.no
4.00
255,
128
'- 128
513
326
':
0'
0
. O
P <0
LG�
.
1.270
no
'35.56
.' 70:43
0
0
0
0
, .. 0
U
0
,. 0
�fy-G
.1Ao1orit.
13A-4ocs
0.143
se
4.00
255
80
56
225
143
48
26
106
67
1Aclom
1.270
se
35.56
34.77
24
24
848
829
0
0
0
0
11
L- D
11DO
0.390
as
10.92
11.31
0
0
0
0
22
22
236
244
w
,13A-4ccs
0.143
s •
4.00
255
34
• 34
136
86
0
0
0
A
�r
13AAccs
0.143
sw
4.00
2.55
16
16
64
41
8
8
32
20
-G
1A-cl m
1.270
sw
35.56
42.91
0
0
0
0
0
0
0
0
V
13A4ccs
0.143
. gw,
4.00
2.55
0
0
0
.0
, 0
' . 0
, 0
0
1Ac1om
1.270
hw'.
35.66
45.24
0
`- 0
'. 0
0
0
.0
0,
- 0
�--C
4A5-2om
0.770
nw
21.55
27.54
0
0
0
0
0
0
0
0
P
12Mw
0.091
-
2.55
1.28
0
0
0
0
72
72
183
92
C
1BA3Dmd
UK
-
0.90
232
204
204
182
472
55
65
49
128
F
22 -tol
0.989
-
27.69
0.00
204
32
891
0
55
7
194
0
6
c)AED mursion
-24
-6
Envelope loss/gain
2859
1873
Boo
545
12
a) Infiltration
564
154
122
34
b) Room ventilation
0
01
D
0
13
Internal gains: Occupants @ 230
1
230
0
0
Apptiancesfother
0
0
Subtotal (fries 6 to 13)
3422
2257
922
579
Less e#emal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
3422
2257
922
579
15
Duct loads
31%
48%
1064
1078
31%
48%
287
276
Total mom load
I
1
4486
3335
1209
855
Air required(cfm)
218
146
59
38
.4&A -FPI- wrightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101
...Wdghtsoft HVACIWYNNE-THE GRAND CARLTON-299.mp Colo =MJ8 Front Door faces:
2017-Apr40 17:14:53
Page 4
wrightsoft RighW@ Worksheet Job:
Entire House Date:
By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM
1
Room name
LAUNDRY
GREATIDINING
2
Exposedwall
6.0 ft
46.0 R
3
Room height
&0 it heaUcool
8.9 it heat/cool
4
Room dimensions
7.0 x 6.0 ft
1.0 x 488.0 it
5
Room area
42.0 it'
488.0 ft2
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft')
Load
number
(Stuh/ft2-°F)
(BtuIvfB)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
I Cod
Gross
WP/S
Heat
Cool
Gross
WPIS
Heat
0001
6
Vy-
-1-G-�1Actont
13A4ccs '.
'0.143
.ne.
4.00
255
0
0
0
0
231
• 194
775
. 493
.'-1.270
ne
35.56
70.43
0
-0
0
.0'
38
0
" 1344
26U
4y
13A-4ws
0.143
se
4.00
2.65
0
0
0
0
0
0
0
0
�LGD
1Aciom
1.270
se
35.58
34.77
0
0
0
0
0
0
0
0
11
11DO
0.390
so
10.921
11.31
0
0
0
0
0
0
0
0
IN,
.13A4ccs
- 0.143
's
.4.OD
'+ 255
0
.0
: 0
- 0
0
- 0
. '0
W
13A4ccs
0.143
sw
4.00
2.65
48
48
192
122
0
0
0
'0
0
�-G
IAclom
1.270
sw
35.56
42.91
0
0
0
0
0
0
0
0
-
Y��1-C
13A460s `
.0.143
nwl'
. ' 4.00
'255
- 0
0
0
.0
178
137
549
349
1Aclom",-
.1.270
nw
.. 35.56'
45.24.
0
0
0
':'0
0:
:0
0;
.
0
�--7i
4AS2an
0.770
my
- 21.56
` . 27.54
0
0
0
.0
41
0
880
1124
P
12C Osw
0.091
-
2.55
1.28
56
56
143
72
0
' 0
0
0
C
16A30md
0.032
-
0.90
232
42
42
38
97
488
468
437
.1132
F
22A-tpl
0.989
-
27.69
0.00
42
6
166
0
488
46
1274
0
6
c)AED mursim
-3
En%elope loss/gain
539
288
5259
5704
12
a) Infiltration
105
29
895
245
b) Room ventaatim
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
2
460
Appliances/other
0
0
Subtotal (lines 6 to 13)
1
644
317
6164
6409
Less entemzl load
0
0
0
0
Less transfer
0
0
0
0
Redistribullon
0
0
0
0
14
Subtotal
644
317
6154
6409
15
Duct loads
31%
48%
200
151
31%
48%
1913
3060
Total room load
844
468
8067
9469
Air required (c1m)
41
21
393
416
Calculations approved byACCA to meet all requirements of Manual J 8th Ed
. A 4j4- wCightsof - Rlght-Suite® Universal 2017 17.0.14 RSU08107 Page 5 2017-Apr-1017:age 5
...Wdghtsoft HVAC\WYMJE-THE GRAND CARLTOW299.rup Colo =MJB Front Door faces: N
Duct System Summary Date:
Entire House By:
QUICK CALCS, INC.
317 ST. LUCIE LN.. FT. PIERCE. FL 34946 Phone: 772-466i6799 Fa1c 772-466-6796 Emil: QUCKCALCS@AOL.COM
Otroject Intorrination
For. WYNNE DEVELOPMENT
THE CARLTON 299, FT. PIERCE, FL
F)ttemal static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
Heating
0.50
in H2O
0
in H2O
0.50
in H2O
0.250 / 0,250
in H2O
0.284
in/100ft
1160
cfm
Cooling
0.50
in H2O
0
in H2O
0.50
in H2O
0.250 / 0.250
in H2O
0.284
in/100ft
1160
cfm
176 ft
Supply Branch Detail Table
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(In)
Duct
Mat]
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH
h 559
27
15
0.376
4.0
OxO
VIFx
18.1
115.0
st1
BEDROOM 2
h 4486
218
146
0.374
6.0
OxO
VIFx
18.6
115.0
st1
BEDROOM -A
h 3501
170
149
0.297
6.0
Ox0
VIFx
33.1
135.0
st2
BEDROOM-B
h 3501
170
149
0.284
6.0
OxO
VIFx
41.1
135.0
st2
ENTRY
h 1209
59
38
0.510
4.0
OxO
VIFx
3.0
95.0
GREAT/DINING
c 4735
196
208
0.318
7.0
0x0
VIFx
22.4
135.0
st2
GREAVDININGE
c 4735
196
208
0.307
7.0
OxO
VIFx
28.1
135.0
st2
KITCHEN
c 3695
21
162
0.375
7.0
OxO
VIFx
18.3
115.0
stl
LAUNDRY
h 844
41
21
0.366
6.0
OxO
VIFx
21.6
115.0
st1
M. BATH
h 1162
57
54
0.366
4.0
OxO
VIFx
21.6
115.0
stl
WIG
c 214
4
9
0.310 1
4.0
Ox0
VIFx
26.3
135.0
st2
Supply Trunk Detail Table
Trunk
Htg
Clg
Design
Veloc
Dlam
H x W
Duct
Name
Type
(cfm)
(cfm)
FR
(fpm)
(In)
(in)
Material
Trunk
st2
Peak AVF
737
724
0.284
689
14.0
0 x 0
VinlFlx
st1
st1
Peak AVF
1101
1122
0.284
804
16.0
0 x 0
VinlFlx
t wri htsoft• 2017-Apr-1017:14:54
�CM9 Rlgtn-Suite® Unrvemat 2017 17.0.14 RSU08101 Page l
...Wrightson WAC%WYNNE-THE GRAND CARLTON-299.mp Cato =MJ8 Front Door faces: N
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FIR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb1
OxO
1160
1160
0
0
0
0
Ox 0
VIFx
- Wrl htsaft' 2017-Apr-10 17:14:54
A-ACC9 RightSuite® Universal 2017 17.0.14 RSUD8101 Page 2
...Wrig tsoR HVAC\WYMJE-THE GRAND CARLTON-299.rup Cats =MJe Front Door faces: N