Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE .FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: 1 LJ (�9 Jurisdiction: Design Location: FL, Fo Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1442.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types (1474.0 sgft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1474.00 ft2 6. Conditioned floor area above grade (ft2) 1474 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(141.3 sgft.) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 300 a. U-Factor: Sgl, U=0.63 101.25 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft2 12. Cooling systems 00, kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit st ^ 34.8 SEER:15.00 c U-FactN/A ft2 O'V'VL �4 `okBtu/hr SHGC: 13. Heating systems 0 Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 0% 34.8 HSPF:8.50 SHGC: l� Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.239 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1473.5 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 48.34 PASS Total Baseline Loads: 48.53 1 hereby certify that the plans and specifications covered by Review of the plans and 4g8E STgl this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance <ri ., y a„ _ `s with the Florida Energy Code. 1~ '-A - PREPARP B Before construction is completed DATE: "�") this building will be inspected for O a compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. COB WS S¢� OWNERK "N BUILDING OFFICIAL: DATE: 11 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 Fy Ce tnoPY 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: WYNNE THE STERLING Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE STERLING Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 604 No 0 1 No Yes Yes 3 M. BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 329 ft2 -_-_ 0 1 0 2SIab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft2 _- 0 1 0 3SIab-On-Grade Edge Insulatio M. BATH 8 ft 0 56 ft2 ___ 0 1 0 4SIab-On-Grade Edge Insulatio KITCHEN 1 ft 0 192 ft' ____ 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft2 ___ 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft2 ____ 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft2 __-- 0 1 0 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft' ____ 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft' _- 0 1 0 ROOF _ / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested insul. (deg) 1 Gable or Shed Metal 1553 ft' 246 ft' Light 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1474 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 329 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 fP 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft' 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft' 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft' 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft' 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below RA/ah Is Pt In Ft In Area R-X/nhip Frgotion Ahqnr 0 1 NE=>SW Exterior Concrete Block - Ext Ins(BEDROOM 4.1 10 0 8 0 80.0 ft' 0 0 0.6 0 2 SW=>NE Exterior Concrete Block - Ext Ins(BEDROOM 4.1 28 0 8 0 224.0 ft' 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext Ins(BEDROOM 4.1 14 0 8 0 112.0 ft' 0 0 6.6 0 _ 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 6 0 8 0 64.0 ft' 0 0 0.6 0 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.6 0 6 NE=>SW Exterior Concrete Block - Ext InRIEDROOM 2 4.1 16 0 8 0 128.0 ft' 0 0 0.6 0 7 SE=>NW Exterior Concrete Block - Ext Infi EDR00M 2 4.1 10 0 8 0 80.0 ft' 0 0 0.6 0 8 S=>N .Exterior Concrete Block - Ext InfilEDROOM 2 4.1 4 3 8 0 34.0 ft' 0 0 0.6 0 9 SW=>NE Exterior Concrete Block- Ext InBEDROOM 2 4.1 2 0 8 0 16.0 ft' 0 0 0.6 0 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft' 0 0 0.6 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft' 0 0 0.6 0 _12 SW=>NE'Exterior Concrete Block - Ext InsdIAUNDRY 4.1 6 0 8 0 48.0 ft' 0 0 0.6 0 _13 NE=>SW Exterior Concrete Block -Ext In98REAT/DINI 4.1 26 0 8 0 208.0 ft' 0 0 0.6 0 _14 NW=>SE Exterior Concrete Block- Ext InaREAT/DINI 4.1 20 0 8 0 160.0 ft' 0 0 0.6 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft' 0.23 0.6 0 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FARM R405-2017 DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal _ 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes 0.63 0.25 N 32.9 ft2 1 ft 0 in 1 ft 4 in 0.63 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in 0.63 0.25 N 24.0 ft2 6 ft 0 in 1 ft 4 in 0.63 0.25 N 37.5 ft2 1 ft 0 in 1 ft 4 in 0.65 0.21 N 40.0 ft2 8 ft 0 in 1 ft 4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315ft2 315ft2 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1375.7 75.53 142.04 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unitt Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 DUCTS / — Supply — — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 300 ft' Attic 75 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programabl[e Y C[ei]ling Fans: Heating [X] ]Thermostarrt: Jan [X� Feb Mar [ [ ] ] AApi' [ ]May Jun rX� [ ]Jul [X] [ ]Aug [ ] Sep v �[r[XX]] Dec Venting II 11 Jan II[ 11 Feb X Mar [X) [ ] lXl Jun I 1 Jul [ ] Aug EX] ] Sep Oct lxl Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (VVD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 5 A2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceilinglattic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an ceiling/soffit Y dropped soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. air Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac Bs. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind pip'no and wirino Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids „ „F�L UL.,, . I ,„s wdna anon ue if du:uwdnae wim me provisions or ruw-4uu. 4/17/2018 2:38 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (W) 7. Windows" Description a. U-Factor: Sgl, U=0.63 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 SHGC: SHGC=0.21 c. U-Factor: N/A SHGC: d. U-Factor. N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A THE STERLING, FT. PIERCE, FL, New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft b. Frame - Wood, Adjacent R=11.0 192.00 ft 1 c. WA R= ft2 2 d. N/A R= ft2 10. Ceiling Types Insulation Area Yes a. Under Attic (Vented) R=30.0 1474.00 ft2 1474 b. N/A R= ft2 Area c. N/A R= ft2 101.25 ft= 11. Ducts R ft' a. Sup: Attic, Ret: Attic, AH: Attic 6 300 40.00 ft' 12. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 34.8 SEER:15.00 ft' 13. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 34.8 HSPF:8.50 3.832 ft. 0.239 Insulation Area R=0.0 1473.50 ft2 R= ft2 R= ft' 14. Hot water systems a. Electric Cap: 40 gallons EF: 0.97 b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. \\ Builder Signature: Date: �� \7\ls� Address of New Home: Zj C�q`rj City/FL Zipt� L" -� 5� *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 h �# wrightsoftProject Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-46"796 Email: For. WYNNE DEVELOPMENT THE CA\RLTOON r. /299, FPIEERC-E,FFIL Notes: `,A Desi n Information Weather. Fort Pierce, FL, US Winter Design Conditions. Outside db 42 OF Inside db. 70, OF Design TD 26 `F Heating Summary Structure 18188 Btuh Ducts 5664 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping. 0 Btuh Equipment load 23842 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Area ft z He 1474 Cc 1474 Volume 1 10 Air changeesrhour 0�.45 3 22 Equiv.AVF (cfm) 92 47 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A`030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual'air flow Air flow factor Static pressure Space thermostat Capacity balance point = 33 OF 8.5 HSPF 34600 Btuh @ 47OF 27 0 1160 cfm 0.049 cfm/Btuh 0.50 in H2O Backup: Input = 7 kW Output = 23009 Btuh, 100 AFUE Job: Date: By: SCq SS t 4UciCpuO. n�, Summer Design Conditions Outside db 90' OF Inside db 75 OF Design TD 15 `F Daily range L Relative humidity 50 % Moisture difference 61 gdlb Sensible Cooling Equipment Load Sizing Structure 17877 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier Equipment sensible load 0.95 25093 Btuh Latent Cooling Equipment Load Sizing Structure 2958 Btuh Ducts 2319 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5277 Btuh Equipment total load 30370 Btuh Req. total capacity at 0.70 SHR 3.0 ton Cooling Equipment Summary Make Carder Trade CARRIER AIR CONDITIONING Cond 25HBC536A'030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actualair flow 1160 cfm Air flow factor 0.044 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -t# blrrightrsoft• Right-Sune® Unlwmai 2Ol7 r7.a14 RSU681g1 2o17-Apr-m 17:14:53 ' � ...Wrightson WAOMM E-THE GRAND CARLTCN-299.rup Cola = MJ6 Front Door faces: N Page 1 .wrightsoft• Right-JOWorksheet Job: Entire House Date: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Emit: OUICKCALCS ,AOLCOM 1 Room name Entire House BEDROOM 2 5ywsed wall 156.2 ft 62.0 ft 3 Room height 8.3 it d 8.0 ft heaticool 4 Room dimensions 1.0 x 329.0 It 5 Room area 1473.5 iP 329.0 ft' Ty Construction U-value Or HTM Area (ft-) Load Area (ftj Load number (BtuWftuF) (Btuhlit j or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WPIS Heat Cool Gross WPJS Heat Cool 6 W� 13A4ocs 0.143 . ne .4.00 2.55 479 442 1768 1124 80 .80 320 - 204 LG: ';1Abtom 1.270 ne 35.56 70.43 38 0 1344 2662' `. 0 0 '- :0 .-` 0 4)I 13A-4ms 0.143 se 4.00 255 128 83 331 210 0 0 0 0 hL-(D' 1Ac1om 1.270 se 35.56 34.77 24 48 848 829 0 0 0 0 11 11DO 0.390 se 10.92 11.31 22 22 236 244 0 0 0 0 W ' 43A4ocs 0.143; a 4:00 255 34 34 - 136 .86 0' ..0 ' 0 0 t-� 13AA= 0.143 sw 4.00 265 360 353 1414 899 224 224 897 670 1Aatom 1270 sw 3556 42.91 7 11 247 298 0 0 0 0 13A4ocs :.0.143 nw. 4.00 ` 2.55 290 217 867 . 551 112 79. - 318 - 202 1Ao1om t270 nw 3566. 45.24 33 .0 -1162 1478. 33.. '0 ` 1162 i ., 1478 -P 4A6-2orn 0.77o tnw 26 t5 .'27.54 41 0: 880 1124" .0 0.. 0 .•0 12C.0sw 0.091 - 2.55 1.28 192 192 489 246 0 0 0 0 C 16A-30md 0.032 - 0.90 232 1474 1474 1320 3419 329 329 295 763 F 22 -tpl 0.989 - 27.69 0.00 1474 156 4325 0 329 52 1440 0 6 c)AED excursion 784 680 Envelope loss/gain 15M 13954 4432 3897 12 a) Infiltration 2822 773 909 249 b) Room ventilation 0 0 0 0 13 internal gains: Occupants@ 230 5 1150 2 460 Applianceslother 20M 0 Subtotal Dines 6 to 13) 18189 17877 5341 4606 Less eldemal load 0 0 0 0 Less transfer0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18188 1.77 5340 4606 15 Duct loads 31% 48% 5654 8536 31% 48% 1660 2199 Total room load 23842 21413 7001 6805 Air required (cfm) 1160 1160 341 299 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed �CZ`h Tb'r wrightsoft• RlghlSuite@ Universal 201717.0.14 RSUD8101 2017-Apr-1017:14:53 ...Wdghtsoft WAC1WYNNE-THE GRAND CARLTON-299.mp Calc=MJ8 Front Door faces: N Page + wrightsoftRight-M) Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: OUICKCALCS@AOLCOM 1 Room name WIC M. BATH 2 Eaqaosed wall 0 ft 8.0 It 3 Room height 8.0 ft heat/cool 8.0 ft heallcool 4 Room dimensions 7.0 x 9.0 It 7.0 x 8.0 ft 5 Room anew 63.0 ft' 56.0 ft' TY Construction U-value Or HTM Am (ftj Load Area (fly Load number (Btu1Vf(MF) (BtUh/fF) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WPIS Heat Cool 6 W 13AA= 0.143' no 4.06 255 • -0 0 0 .0 0 0 0 0 L-G- JActan 1.270 -:ne<. -35.56 ..70.43:. .0 0 .. 0 •0 0. 0 :0 . -'0 4�l!-�` 13A4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 IA-clown1.270 se 35.56 34.77 0 0 0 0 0 0 0 0 11 `D 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W 13A-0acs 0.143 s 4.00 2.65 0 •0 0 0 0 0 () I ' 0 W 13A4o s 0.143 sw 4.00 255 0 0 0 0 64 57 228 145 1Aclon _ 1270 sw 35.56 42.91 0 0 0 0 7 5 247 298 1.11f- 13A-4ocs .0143 hw 400 ' 2.55 0 0 0 0 l> .0 0 - '- 0 -1A=clom -1270 rov 35:56 45:24 0. -0• 0 0 0-. ..p;- 0 0 4A.5-2om' . "0.770 nw 21.56 27.54 0 0 ' 0 '0 0 0 0 ' - 0 P 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 0 0 0 0 C 16A30md 0.032 • 0.90 Z32 63 63 56 146 56 66 60 130 F 22A-tot 0.989 - 27.69 0.00 63 0 0 0 56 8 222 0 8 c)AFJO excursion -2 225 Envelope losslgain 66 145 747 798 12 a) Infiltration 0 0 140 38 b) Room ven ilatim 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Qirles 6 to 13) 56 145 887 gib Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 14 Subtotal 55 145 887 836 15 Duct loads 31% 48% 18 69 31% 480/6 276 399 al md lead '4 219 1167 1235 AToirt) 54 Calculations approved byACCA to meet all requirements of Manual J 8th Ed A wrightsoft• Right -Suite® Universal 201717.0.14 RSU08101 2017-Apr-1017:14:53 ...Wdghlsoft WtlACIWYNNE-THE GRAND CARLTON-299.mp Cale = MJ8 Front poor faces: N Page 2 + wrightsoft• Right+J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-46"796 Emil: QUICKCALCS@AOL.COM 1 Room name KITCHEN BqH 2 Emposed wall 0 ft 5.0 ft 3 Room height &0 ft heat/cool 8.0 It heat/cool 4 Room dimensions 1.0 x 192.0 ft 9.0 x 5.0 ft 5 Room area 1920 ft° 45.0 ft- Ty construction U-value Or HTM Area (ft2) Load Area Load number (RUWRx°F) (BtUWfN) or perimeter (ft) (Ruh) or perimeter (ft) (Ruh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 W � '13A4ocs' 0.143 ne - 4.00 . 2.55 0 0 - 0 0 40 40 160 �102 LG 1Actonn 1.270 ne 35.66 70.43 0' -0 0- 0 -0 0: ,0 WI-G 13AAccs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1.270 se 35.56 34.77 0 0 0 0 0 0 0 0 11DO '.13AAocs 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 w 0.143: a .4.00 255 0 0 - 0 -. 0 0 0 .0 0 W Y-G IaA4ocs 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1.270 sw 3556 4291 0 0 0 0 0 0 0 0 13A-4ocs 0:143 nw 4 00 2.55 0 " 0 - 0 - :0 :' 0 : • 0 . .0 ' � ' 0 1Ac1om. 1.270 , my 35 56 i 7 45.24 :0 - 0 , 0 - - 0 - , .a ' +0 . ' 0 - -; 0 .0.770 nw, 21.56 - -27.54 0 0 " 0 0 0 0 - 0 .= "0 P 12COsw 0.091 - 2.65 1.28 64 64 163 82 0 0 0 0 C 16A-30md 0.032- 0.90 2.32 192 192 172 445 45 45, 40 104 F 22A-tpl 0.989 - 27.69 0.00 192 0 0 0 45 5 138 0 6 c)AED excursion -27 -p Envelope loss/gain 335 501 339 204 12 a) Infiltration 0 0 87 24 b) Room ventilation 0 0 0 0 13 Irtemal gains: Occupants @ 230 0 0 0 0 Appliances/other 2000 0 Subtotal Qines 6 to 13) 335 2501 426 228 Less ademal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 335 2501 426 15 Duct loads 31% 48% 104 1194 31% 48% 133 109 109 Tatal room load 439 3695 559 336 Alr required (cfm) 21 162 27 15 �4� Calculations approved byACCA to meet all requirements of Manual J 8th Ed .A -'7� wrightsoR• RlghtSulte® Universal 2017 17.0.74 RSUD8101 2017-Apr-1017:14:53 ...Wnghtsoft FNAC1WYMJE-71iE GRAND CARLTersal2 17 Cale=MJB SUD Front Daor faces: N Page 3 wrightsoft• RighWO Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE I-M, FT. PIERCE, FL 34946 Phone: 772-466-6799 Fa c 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM ENTRY 2 Egased wall 32.2 It 7.0 ft 3 Room height 8.0 R heattcool 8.0 R heat/cool 4 Room dimensions 1.0 x 203.5 If 1.0 x 65.0 It 5 Room area 203.5 ft- 55.0 ft- Ty Construction Or AM er Load Am Load u bere number (Btuh/fMF) (Btuwftl) or perimetHTM (ft) (BlW) or Perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S. Heat Cool - 6 y1 � ,13A-4ms "0.143 .no 4.00 255, 128 '- 128 513 326 ': 0' 0 . O P <0 LG� . 1.270 no '35.56 .' 70:43 0 0 0 0 , .. 0 U 0 ,. 0 �fy-G .1Ao1orit. 13A-4ocs 0.143 se 4.00 255 80 56 225 143 48 26 106 67 1Aclom 1.270 se 35.56 34.77 24 24 848 829 0 0 0 0 11 L- D 11DO 0.390 as 10.92 11.31 0 0 0 0 22 22 236 244 w ,13A-4ccs 0.143 s • 4.00 255 34 • 34 136 86 0 0 0 A �r 13AAccs 0.143 sw 4.00 2.55 16 16 64 41 8 8 32 20 -G 1A-cl m 1.270 sw 35.56 42.91 0 0 0 0 0 0 0 0 V 13A4ccs 0.143 . gw, 4.00 2.55 0 0 0 .0 , 0 ' . 0 , 0 0 1Ac1om 1.270 hw'. 35.66 45.24 0 `- 0 '. 0 0 0 .0 0, - 0 �--C 4A5-2om 0.770 nw 21.55 27.54 0 0 0 0 0 0 0 0 P 12Mw 0.091 - 2.55 1.28 0 0 0 0 72 72 183 92 C 1BA3Dmd UK - 0.90 232 204 204 182 472 55 65 49 128 F 22 -tol 0.989 - 27.69 0.00 204 32 891 0 55 7 194 0 6 c)AED mursion -24 -6 Envelope loss/gain 2859 1873 Boo 545 12 a) Infiltration 564 154 122 34 b) Room ventilation 0 01 D 0 13 Internal gains: Occupants @ 230 1 230 0 0 Apptiancesfother 0 0 Subtotal (fries 6 to 13) 3422 2257 922 579 Less e#emal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3422 2257 922 579 15 Duct loads 31% 48% 1064 1078 31% 48% 287 276 Total mom load I 1 4486 3335 1209 855 Air required(cfm) 218 146 59 38 .4&A -FPI- wrightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 ...Wdghtsoft HVACIWYNNE-THE GRAND CARLTON-299.mp Colo =MJ8 Front Door faces: 2017-Apr40 17:14:53 Page 4 wrightsoft RighW@ Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUNDRY GREATIDINING 2 Exposedwall 6.0 ft 46.0 R 3 Room height &0 it heaUcool 8.9 it heat/cool 4 Room dimensions 7.0 x 6.0 ft 1.0 x 488.0 it 5 Room area 42.0 it' 488.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft') Load number (Stuh/ft2-°F) (BtuIvfB) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cod Gross WP/S Heat Cool Gross WPIS Heat 0001 6 Vy- -1-G-�1Actont 13A4ccs '. '0.143 .ne. 4.00 255 0 0 0 0 231 • 194 775 . 493 .'-1.270 ne 35.56 70.43 0 -0 0 .0' 38 0 " 1344 26U 4y 13A-4ws 0.143 se 4.00 2.65 0 0 0 0 0 0 0 0 �LGD 1Aciom 1.270 se 35.58 34.77 0 0 0 0 0 0 0 0 11 11DO 0.390 so 10.921 11.31 0 0 0 0 0 0 0 0 IN, .13A4ccs - 0.143 's .4.OD '+ 255 0 .0 : 0 - 0 0 - 0 . '0 W 13A4ccs 0.143 sw 4.00 2.65 48 48 192 122 0 0 0 '0 0 �-G IAclom 1.270 sw 35.56 42.91 0 0 0 0 0 0 0 0 - Y��1-C 13A460s ` .0.143 nwl' . ' 4.00 '255 - 0 0 0 .0 178 137 549 349 1Aclom",- .1.270 nw .. 35.56' 45.24. 0 0 0 ':'0 0: :0 0; . 0 �--7i 4AS2an 0.770 my - 21.56 ` . 27.54 0 0 0 .0 41 0 880 1124 P 12C Osw 0.091 - 2.55 1.28 56 56 143 72 0 ' 0 0 0 C 16A30md 0.032 - 0.90 232 42 42 38 97 488 468 437 .1132 F 22A-tpl 0.989 - 27.69 0.00 42 6 166 0 488 46 1274 0 6 c)AED mursim -3 En%elope loss/gain 539 288 5259 5704 12 a) Infiltration 105 29 895 245 b) Room ventaatim 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 1 644 317 6164 6409 Less entemzl load 0 0 0 0 Less transfer 0 0 0 0 Redistribullon 0 0 0 0 14 Subtotal 644 317 6154 6409 15 Duct loads 31% 48% 200 151 31% 48% 1913 3060 Total room load 844 468 8067 9469 Air required (c1m) 41 21 393 416 Calculations approved byACCA to meet all requirements of Manual J 8th Ed . A 4j4- wCightsof - Rlght-Suite® Universal 2017 17.0.14 RSU08107 Page 5 2017-Apr-1017:age 5 ...Wdghtsoft HVAC\WYMJE-THE GRAND CARLTOW299.rup Colo =MJB Front Door faces: N Duct System Summary Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN.. FT. PIERCE. FL 34946 Phone: 772-466i6799 Fa1c 772-466-6796 Emil: QUCKCALCS@AOL.COM Otroject Intorrination For. WYNNE DEVELOPMENT THE CARLTON 299, FT. PIERCE, FL F)ttemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0,250 in H2O 0.284 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 cfm 176 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (In) Duct Mat] Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 559 27 15 0.376 4.0 OxO VIFx 18.1 115.0 st1 BEDROOM 2 h 4486 218 146 0.374 6.0 OxO VIFx 18.6 115.0 st1 BEDROOM -A h 3501 170 149 0.297 6.0 Ox0 VIFx 33.1 135.0 st2 BEDROOM-B h 3501 170 149 0.284 6.0 OxO VIFx 41.1 135.0 st2 ENTRY h 1209 59 38 0.510 4.0 OxO VIFx 3.0 95.0 GREAT/DINING c 4735 196 208 0.318 7.0 0x0 VIFx 22.4 135.0 st2 GREAVDININGE c 4735 196 208 0.307 7.0 OxO VIFx 28.1 135.0 st2 KITCHEN c 3695 21 162 0.375 7.0 OxO VIFx 18.3 115.0 stl LAUNDRY h 844 41 21 0.366 6.0 OxO VIFx 21.6 115.0 st1 M. BATH h 1162 57 54 0.366 4.0 OxO VIFx 21.6 115.0 stl WIG c 214 4 9 0.310 1 4.0 Ox0 VIFx 26.3 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Dlam H x W Duct Name Type (cfm) (cfm) FR (fpm) (In) (in) Material Trunk st2 Peak AVF 737 724 0.284 689 14.0 0 x 0 VinlFlx st1 st1 Peak AVF 1101 1122 0.284 804 16.0 0 x 0 VinlFlx t wri htsoft• 2017-Apr-1017:14:54 �CM9 Rlgtn-Suite® Unrvemat 2017 17.0.14 RSU08101 Page l ...Wrightson WAC%WYNNE-THE GRAND CARLTON-299.mp Cato =MJ8 Front Door faces: N Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 OxO 1160 1160 0 0 0 0 Ox 0 VIFx - Wrl htsaft' 2017-Apr-10 17:14:54 A-ACC9 RightSuite® Universal 2017 17.0.14 RSUD8101 Page 2 ...Wrig tsoR HVAC\WYMJE-THE GRAND CARLTON-299.rup Cats =MJe Front Door faces: N