Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT SCA Street: THE STERLING Permit Office: ST. LUCIE COUNTY NFL City, State, Zip: FT. PIERCE, FL, Permit Number: Sg a Y Owner., 'p'-G Juri/ sdiction: �uC, t? COUnt Design Location: FL, Fp Pierce ` ` County:: St. Lucie (Florida Climate Zone 2) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types (1474.0 sgft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1474.00 ft2 6. Conditioned floor area above grade (ft2) 1474 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(141.3 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 300 a. U-Factor: Sgl, U=0.63 101.25 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency 'd. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.239 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1473.5 sgft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 48.34 PASS Total Baseline Loads: 48.53 I hereby certify that the plans and specifications covered by Review of the plans and g•fHE Srgl this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance °„ �O with the Florida Energy Code.DEC ¢Nrxe ?f •, t; ;,•;;.•, PREPAR B Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 tt0 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AA��FFNT, i r � 9 BUILDING OFFICIAL: t''0 WE�� DATE: A- 'y% � DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (RQ2,1.2 . 4/17/2018 12:27 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: WYNNE THE STERLING Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE STERLING Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, Stale, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M. BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 329 ft' 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft' ____ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft' — 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN t ft 0 192 ft' ____ 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft' ___ 0 1 0 7SIab-On-Grade Edge Insulatio ENTRY 7 ft 0 55 ft' _r 0 1 0 4/17/2018 12:27 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ---- 0 1 0 9SIab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1553 ft2 246 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1474 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 329 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 NE=>SW Exterior Concrete Block - Ext Ins®EDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 2 SW=>NE Exterior Concrete Block - Ext Ins®EDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext Ins®EDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 _ 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 5 NE=>SW Exterior Concrete Block- Ext Insul BATH 4.1 5 0 8 0 40.0 112 0 0 0.6 0 _ 6 NE=>SW Exterior Concrete Block - Ext InREDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 7 SE=>NW Exterior Concrete Block - Ext InfiEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 8 S=>N Exterior Concrete Block - Ext InREDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.6 0 9 SW=>NE Exterior Concrete Block- Ext IndWDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 _11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 _12SW=>NEExterior Concrete Block - ExtlnsdlAUNDRY 4.1 6 0 8 0 48.0ft2 0 0 0.6 0 13 NE=>SW Exterior Concrete Block - Ext Ins REAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.6 0 14 NW=>SE Exterior Concrete Block - Ed Ins REAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.6 0 _15 N=>S Garage Frame -Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.6 0 4/17/2018 12:27 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 0.63 0.25 N 32.9 ft' 1 it 0 in 1 it 4 in 0.63 0.25 N 6.9 ft' 1 ft 0 in 1 It 4 in 0.63 0.25 N 24.0 ft' 6 ft 0 in 1 ft 4 in 0.63 0.25 N 37.5 ft' 1 It 0 in 1 It 4 in 0.65 0.21 N 40.0 ft' 8 it 0 in 1 ft 4 in Drapes/blinds None None None Drapesiblinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft' 24It 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1375.7 75.53 142.04 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Can # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' 4/17/2018 12:27 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FnRM R4n5-9n17 DUCTS — Supply — — Return — Air CFM25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 300 ft' Attic 75 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Ceiling Fans: ]Thermostafft:]]Y Heating [X] Jan [X] Feb [[ ] [X] Mar ] i ] Apr May [ [X� Jun r [X� Jul [ ] [X] Aug [ ] Sep [ j LJ Qc Nov Dec Venting I 1 Jan II[ I Feb [Xl Mar [Xl I Jun [ Jul [)Aug Ex] ]Sep Lxl Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/17/2018 12:27 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall behind rinono and wiring Shower/tub The air barrier installed at exterior walls adjacent to showers and _e2dend Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, Inspection of log wails snail be in accordance with the provisions of ICC-400. 4/17/2018 12:27 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. THE STERLING, FT. PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft' b. Frame - Wood, Adjacent R=11.0 192.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft. 4. Number of Bedrooms 2 d. N/A R= ft' 5. Is this a worst case? 10. Ceiling Types Yes Insulation Area a. Under Attic (Vented) R=30.0 1474.00 ft' 6. Conditioned floor area (W) 1474 b. N/A R= ft' 7. Windows" Description Area c. N/A R= ft a. U-Factor: Sgl, U=0.63 101.25 ft2 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft' 6 300 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.06 ft' SHGC: SHGC=0.21 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft' a. Central Unit 34.8 SEER:15.00 SHGC: d. N/A r. ft' SHGC: SHGC: 13. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.239 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft a. Electric EF: 0.97 b. N/A R= ft' c. N/A R= fP b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. G BuilderSignature: Date: \��`?:: 0 Address of New Home: aT1 City/FL Zip..-- r *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/17/2018 12:27 PM EnergyGauge® USA - Flaftes2017 - Section R405.4.1 Compliant Software Page 1 of 1 - wrightsoft' Project Summary Dab Entire House By: QUICK.CALCS, INC. 317 ST. LUCIE LK, FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Emil: OUICKCALCS@AOLCOM — - Project Information For. WYNNE DEVELOPMENT THE CARLTON 299, FT. PIERCE, FL SCANNED G Notes: 1 BYSt. Lucie County Weather. Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TO 26 `F Heating Summary Structure 18188 Btuh Ducts 5654 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Pipingr 0 Btuh Equipment load 23842 Btuh Infiltration Method Construction quality Fireplaces Fort Pierce, FL, US Simplified Average 0 Area (ft)2 Hea1471 Co 14i A Volume(ft') 12227 12227 Airchanges/hour 0.45 0.23 Equiv. AVF (cfm) 92 47 Heating. Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Model 25HBC536A'030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 33 OF 8.5 HSPF 34600 Btuh @ 47OF 27 0 OF 1160 0.049 cfm/Btuh 0.50 in H2O Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TO 15 'F Daily range Relative humidity L 50 0/a Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 17877 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier Equipmenf 0.95 sensible load 25093 Btuh Latent Cooling Equipment Load Sizing Structure 2958 Btuh Ducts 2319 Btuh Central vent (0 cfm) 0_ Btuh (none) Equipment latent load 5277 Btuh Equipment total load 30370 Btuh Req. total capacity at 0.70 SHR 3.0 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A•030 Coil FX4DN((B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual airflow 1160 cfm Air flow factor 0.044 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed wrightsofr Right-SuRe® UnlNersal 2017 17.0.14 RSU08101 2017-Apr-1017:14:53 ' � ...Wrightsoft WAC\WYNNE-THE GRAND CARLTON-299.rup Calc=MJ8 Front Door faces: N Page 1 + wrightsi Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Emil: OUICKCALCS@AOL.COM 1 Room name _ Enthe House BEDROOM 2 E19osed wall 156.2 ft 62.0 ft 3 Room height 8.3 ft d 8.0 ft heallcool 4 Room dimensions 1.0 x 329.0 ft 5 Room ama 1473.5 ft' 329.0 ft' Ty Construction U-value Or HTM Area (ft) Load Area In Load number (BtuIVWF) (BtuWft2) or perimeter (ft) (Btuh) or perimeter (ft) ) Heat Cool Gross N/P/S Heat Cool Gross ' WP/S Heat Cool 6 Vy 13AA06; 0.143 .no. 4.00 - 255 479 442 1768 1124 80' 80 320 204 .1Aclom 1.270 ne, 35.56 - 70.43 . 38 .. >0 :1344, 2662 . -. 0' 0 - .0,.- .;o Vi 13AAocs 0.143 se 4.00 2.55 128 83 331 210 0 0 0 0 �G I-D 1Ac1wn 1.270 se 35.56 34.77 24 48 848 829 0 0 0 0 11 11DO 0.390 as 10.B2 11.31 22 22 236 244 0 0 0 0 W,' 43A4ocs 0.143 a 4:00 255 34 34 136 86 0 - . 0 ' 0 0 W 13AAccs O. sw 4.OD 255 360 353 1414 899 224 224 897 570 1Aotan 1.770 sw 35.56 42.91 7 11 247 298 0 0 0 0 -6 Vy 13A4ccs "' .0143 nw.. , 4 00 :' 255 . 290 217 ` , 867 . 551 112 '79 ' ' 318 202 l�-CC tAc1cm 1:270:'mv '3556= 45.24 33 0 1162 .1478 '33. ;A; 1162 'r1478 4AB-20o:. ;0.770 ''rw 21.56 - '27.54 41 . 0 880 -- 1124 0 0: . 0 10 �f' 12C-0sw 0.091 - 2.55 1.28 192 192 489 240 0 0 0 0 C .16A30md 0.032 - .0.90 2.32 1474 - 1474 1320 3419 329 329 295 763 F 22A-tPI 0.989 - 27.69 0.00 1474 156 4325 0 329 52 1440 0 6 c)AED excursion 784 680 Envelope loss/gain 15366 13954 4432 3897 12 a) Infiltration 2822 773 909 249 b) Roomventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 1150 2 460 Applences/other 2000 0 Subtotal Qmes 6 to 13) 18188 17877 5341 46M Less eldemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18188 17877 5341 4606 15 Duct loads 31% 481 5654 8536 31% 48% 1660 2199 Total room load 23842 26413 7OD1 6805 Air required (cfm) 1160 1160 341 299 Calculations approved byACCA to meet all requirements of Manual J 8th Ed A - wrighlsofY RlghtSulteO Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:14:53 ...Wdghisoft HVAC1WVNNE-THE GRAND CARLTON-299.rup Cale =MJB Front Door faces: N Page 1 +# wrightsoft' Right-M Worksheet Job: Entire House Date: sy: QUICK CALCS, INC. 317 ST. LUCIE I.M. FT. PIERCE, FL 34946 Phone: 772-066-6799 Fax 772-466-6796 Emil: OUICKCALCSa,AOL.COM 1 Room name WIC M. BATH 2 Exposed wall 0 ft 8.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heaticool 4 5 Room dimensions Room area 7.0 x 9.0 It 63.0 W 7.0 x 8.0 It 56.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (W) Load number (BtulVft;°F) (BlulVft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heal Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 Vy I--G 13A-4= `0.143 no 4.00 ' 255 0 -0 - 0 0 0. 0 0 ` '0 1A-c1an 13A-0ocs 1.270 0.143 -ne- se 135.56 4.00 70.43 2.55 0 0 0 0 0 0 0 0 0' 0 0 0 '.0 0 '. - 0 0 I 11 I(---GD 1Aaiom 11DO 1.270 0.390 se se 35,56 10.92 34.77 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W W, 13AAocs 13A-0ocs -0.143 0.143 a sw 4.00 4.00 255 255 0 0 0 0 0 0 0 0 0' 64 to 57 228 0 145 --G . 1Actom 13A-0dcs - 1Ac1om - 4LS20M 12C-0sw -16A30md- 2244pl 1270 .0143 .1270 -'0.770..ray 0.091 0.032 0.989 sw Inw .nw. - - - 3556 400 3556: 21.56 2.55 0.90 27.69 42.91 . 2:55 ..45:24: • '27.54 1.28 232 0.00 0 0 ., 0 0 0 63 63 0 0 -0 0 0 63 0 0 0 0 ' - 0 0 56 0 0 0 0 .0 0 146 0 7 - 0 - ..p: 0 0 66 56 5 0 - ." .p -0 0 66 8 247 0 p .. 0 0 50 222 298 p:r , i0 Z- 0 0 130 0 P C F 6 c)AED exclusion -2 225 Enwlope loss/gain 56 145 747 798 12 a) Infiltration b) Roomventilation 0 0 0 0 140 0 38 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal Ohm 6 to 13) 56 145 887 836 14 15 Less eDdemal load Less transfer Redistribution , Subtotal Dud loads 31% 48% 0 0 0 56 18 0 0 0 145 69 31% 48% 0 0 0 887 276 0 0 0 836 3" Total room lcatl Alr requiretl (dm) 74 4 214 9 1162 57 1235 54 Calculations approved byACCA to meet all requirements of Manual J 8th Ed /(OVA wrightsoft- RlghlSuite@ Universal 201717.0.14 RSU08101 2017-Apr-1017:14:63 ...Wdghtsoft WACIWYNNE-THE GRAND CARLTON-299.rup Cale =MJB Front Door faces: N Page wrightsoft• RighW@ Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST LUCIE LN., FT. PIERCE, FL 34M Phone: 772-466-6799 I = 772466£796 Email: OUICKCALCS@,AOLCOM 1 Room name WCHEN BATH 2 E)pgsed wall 0 ft 5.0 ft 3 Room height 8.0 If heat/cool 8.0 It heaticool 4 Room dimensions 1.0 x 192.0 ft 9.0 x 5.0 ft 5 Room area 1920 ft' 45.0 ftr Ty Construction U-value Or HTM Area (ft-) Load Prey (fti Load number (BtutVfti°F) (Stulvft� or perimeter (f0 (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 13A4ocs 0.143. no 4.00 - 255 0 0 0. 0 40 40 '160 ., 102 �--G 1Aa1om: 1.270 ne 35.56 70.43 0 =0 0 .00- o, o ,� c:... . ;0 vL 13A4ccs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 F-G �D 1Ao1om 1.270 se 35.66 34.77 0 0 0 0 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W -13A4= 0.143 's :4.00 2.55 0 0- 0. 0 0 0 ...0 0 V�1 13A4= 0.143 sw' 4.00 Z55 0 0 0 0 0 0 0- 0 I--G 1Aaian 1.270 sw 35.56 4291 0 0 0 0 0 0 0 0 13A-0dcs� - 0143 -1.270 nvi 400 '2.55 0 0 0 0' .0• .0, 0 ':O .1Ac1w mv:" 3556 45.24 0 0 0. 0 °0" 0- .';0 05-2orn .0.770 nw,, 21.56 :27.54 -0 0 0'L 0. :0 `0 ls. 0 P 12C41sw 0.091 - 2.55 1.28 64 64 163 82 0 0 .0 0 - 0 C 16A-,90rnd '0.032 - 0.90 232. 192 192 172 445 45 45 40 104 F 22A-tpl 0.989 - 27.69 0.00 192 0 0 0 45 5 138 0 6 c)AED excursion -27 -2 Enwlope loss/gain 335 501 339 204 12 a) Infi0rallon 0 0 87 24 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 20M 0 Subtotal Oms; 6 to 13) 335 2501 426 228 Less ademal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 14 Subtotal 335 2501 426 ,0 228 15 Duct loads 31% 481/6 104 1194 31% 48% 133 109 Total room lead 439 3695 559 336 AIr required (crm) 21 162 27 15 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. . h wrightsoft- RlghtSulte® Universal 2017 17.0.14 RSUD8101 2017-Apr-1017:14.53 ...Wrightsoft HVAC1WYNI4E-THE GRAND CARLTON-299.rup Cale =MJB Front Door faces: N Page 3 wrightsoft• Right-J® Worksheet Date: Entire House Date By; QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466.8796 Emil; QUICKCALCS AOL.COM 1 2 3 4 5 Room name ENrosed wall Room height Room dimensions Room aura BEDROOM 2 32.2 ft 8.0 ft heaticool 1.0 x 203.5 ft 203.5 ft' ENTRY 7.0 It 8.0 It heal/cool 1.0 x 65.0 ft 55.0 ft. Ty number (BulJftmF) Or (Btuhfft-) or periArea meter (ft) (Btuh) eorperimeter (ft) (Btuh) Heat Cool Gross NIPIS Heat Cool Gross NIP/S. Heat Cool 6 1134-0GI l--f;:1A-clan 13A4ccs '0.143 1.270'ne 0.143 T.ne se 4.00. '35.56 4.00 255 70.43 2.55 128: . -0. 80 128 0 56 513 0. 225 326 0 143 0' . 0 48 ;0, 0 26 0. '0. 1D6 ' �'0 0 67 11 I-D 1Ac1om 11DO 1.270 0.390 se se 35.56 10.92 34.77 11.31 24 0 24 0 848 0 829 0 0 22 0 22 0 236 0 244 IN t-G 13A4ocs 13A-0acs 0.143 0.143 a sw 4.00 4.00 265 255 34 16 34 16 136 64 86 41 0 B - 0 8 0 32 -� 0 20 1Actoin 1.270 sw 35.56 4291 0 0 0 0 0 0 0 0 4j�1-c''1Ac1om. 13A-0ocs 0.143 - 1.270, nw nw 4:00 35.56 -255 :45.24 _ 0 0 0 - 0 '0 ! 0 -0' 0' 0 0 '0 .0 0 0 '0 .`=0 T--C- 4A5-20m 0.770 nw 21.56 27.54 0 0 . 0 0 0 0. 0 0 P 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 72 72 183 92 'C 16A30md 0.032 - 0.90 2.32 204 2D4 182 472 65 55 49 .: 128 F 22A401 0.989 - 27.69 0.00 204 32 891 0 65 7 194 0 6 c)AED mursion -24 -6 EnrMope loss/gain 2859 1873 800 545 12 a) Infiltration 564 154 122 34 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtatel Quies 6 to 13) 3422 2257 922 579 14 Less a"'anal load Less transfer Redistribution Subtotal 0 0 0 3422 0 0 0 2257 g 0 0 922 0 g 0 679 15 Duct loads 31% 48% 1064 1078 31% 48% 287 276 Total room load Airr,quired(ofm) 4486 218 3335 146 1209 59 855 38 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed -Fp- wrilghCsoftr Right -Suite® Universal 201717.0.14 RSU08101 2017-Apr-10 17:14:53 A...Wdghtsoft WAC1WYNNE-THE GRAND CARLTON-299.rup Calc=MJB Front Doorfaces: N Page wrightsoftRighWO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Faz 772-466-6796 Email: OUICKCALC6 AOLCOM 1 Room name LAUNDRY GREAT/DINING 2 Elrposed wall 6.0 ft 46.0 ft 3 Room height 8.0 ft heat/cool 8.9 ft heaticool 4 5 Room dimensions Room area 7.0 x 6.0 it 42.0 ft' 1.0 If 488.0 ft 488.0 ft' Ty Consbuctlon U-value Or HTM Area (fl2) Load Area (ftq Load number (BtuIVftMF) (BtUiVft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross WP/S Heat Cool Gross WP/S Heat Cool 6 lRl_ I-G 13A4ocs'• 0.143 ne. 4.00 2,55 . ;0 0' .0 - 0 231 . 194 775 ,- 493 1Acl m . ..' .1.270 'ne ,'.. 35.66 ..70.43 . .0 ..._ 0.. 0 0. ..: 38'. 0 '= 1344 '.r".2662 y/ 13A4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11 �LG D 1Aaiorn 11DO 1.270 0.390 se se 35.56 10.92 34.77 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W 13A,4ms - 0.143 s . �4.00 255 0 0 0- 0 0 r 0 -. N/ I--(' 13A-4 cs 0.143 sw 4.00 2.55 48 48 192 122 0 0 ,<0 0 ,0 0 tom 1143 sw 34.00 4291 0 0 0 0 0 0 0 0 :Mnclorn 0270'nw 4.56 .. 0, • 0 0 - .0 178 137, 549 . 349 1Ao1om `�� .. '•1.270 �nw-.. - 35.56 �• 45:24, 5.24 .0• 0`. 0• ::0 0 a0 4A5-2om 0.770 nw 21.56 27.54 0 01 0 0 41 b 860 1124 P 12C-0sw 0.091 - 2.55 1.28 56 56 143 72 0 ' 0 0 0 C 1GA30md 0.032 - 0.90 232 42 42 38 97 488 488 437 .1132 F 22A-tpl 0.989 - 27.69 0.00 42 6 166 0 488 46 1274 0 I 6 c)AED excursion -3 -56 Envelope loss/gain 539 288 5259 5704 12 a) Infiltration 105 29 895 245 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal Qirles 6 to 13) 644 317 6154 6409 Less eldemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 644 317 6154 6409 15 Duct loads 31% 480/. 200 151 31% 48% 1913 3060 Total room load Air required(cfm) 844 41 468 21 8067 393 946 41 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightaoft- RlghtSuite49 Universal 201717.0.14 RSU08101 2017-Apr-1017:14:53 ��A... Wrightsoft WAC%WYPe4E-THE GRAND CARLTON-299.rup Cato =MJ8 Front Door faces: N Page wrightsoft Duct System Summary Job: y Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-46"799 Fas 772-466-6796 Email: OUICKCALCS AOL.COM irroject Intormation For-. WYNNE DEVELOPMENT THE CARLTON 299, FT. PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 Cfm 176 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diann (in) H x W (in) Duct Mat] Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 559 27 15 0.376 4.0 OxO VIFx 18.1 115.0 st1 BEDROOM 2 h 4486 218 146 0.374 6.0 Ox0 VIFx 18.6 115.0 st1 BEDROOM -A h 3501 170 149 0.297 6.0 OxO VIFx 33.1 135.0 st2 BEDROOM-B h 3501 170 149 0.284 6.0 OxO VIFx 41.1 135.0 st2 ENTRY h 1209 59 38 0.510 4.0 OxO VIFx 3.0 95.0 GREAT/DINING c 4735 196 208 0.318 7.0 OxO VIFx 22.4 135.0 st2 GREAVDINING-B c 4735 196 208 0.307 7.0 OxO VIFx 28.1 135.0 st2 KI?CHEN c 3695 21 162 0.375 TO OxO VIFx 18.3 115.0 st1 LAUNDRY h 844 41 21 0.366 6.0 OxO VIFx 21.6 115.0 st1 %BATH h 1162 57 54 0.366 4.0 Ox0 VIFx 21.6 115.0 st1 wic c 214 4 9 0.310 1 4.0 Ox0 I VIFx 1 26.3 1 135.0 s12 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (Cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 737 724 0.284 689 14.0 0 x 0 VinlFlx st1 st1 Peak AVF 1101 1122 0.284 804 16.0 0 x 0 VinlFlx . F�{.�� Wrl htsloft' ton-Apr-1017:14:54 �� - I' 9 RlghtSuilehJ Universal 2017 17.0.14 RSU08101 Page 1 ...Wrightsoft WAC%WYNNE-THE GRAND CARLTON-299.mp Cato =MJ8 Front Door faces: N Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 1 VIFx " wri �1ti8Oft' 2017-Apr-1017:14:54 9 Right-SuBe® Univeisa1201717.0.14 RSU08101 Page 2 ... W ghlsoft HVAC%WYMVE-THE GRAND CARLMN-299.mp Cato = MJ8 Front Door faces: N