Loading...
HomeMy WebLinkAboutEVALUATION REPORTCREEK Certificate ofAut17520tion bur 29824 17520 Edinburgh Drive Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6Te EDITION (2017) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued October 11, 2017 1 Owens Coming Parkway Toledo, OH 43657 (800)438-7465 www.owenscoming.com Manufacturing Location: Brentwood, NH Houston, Tx SCANNED Quality Assurance: UL LLC (QUA9625) St. Lucie County County SCOPE Category: Roofing Subcategory: Undedayments Code Sections: 1504.3.1, 1507.1.1 Properties: Physical properties REFERENCES Enti Report No. Standard Year PRI Construction Materials Technologies (TST5878) NEI-039.02-01 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) NEI-042-02-01 REV2 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) NEI-045-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST5878) NEI-045-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST5878) NEI.053-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST5878) NEI 63.02.01 ASTM G 155 2005a PRI Construction Materials Technologies (TST5878) NEI.093.02-02 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) OCF-213-02-01 ASTM D 1623 2009 PRI Construction Materials Technologies (TST5878) OCF-237-02-01 UL 1897 2012 PRI Construction Materials Technologies (TST5878) OCF-252-02-01 ASTM D 4798 2001 PRI Construction Materials Technologies (TST5878) OCF-252-02-01 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) OCF-253-02-02 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) OCF-272-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST5878) OCF-296-02-02 ICC-ES AC 188' 2012 ICC•ES AC 48 2012 PRI Construction Materials Technologies (TST5878) OCF-297-02.01.1 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) OCF-318-02.01 ASTM D 1970 2016 PRI Construction Materials Technologies (TST5878) OCF-320-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST5878) OCF-320-02-01 ASTM G 155 2005a PRI Construction Matedals Technologies (TST5878) OCF-321-02.01 ASTM D 1623 2009 PRI Construction Materials Technologies (TST5878) OCF-322-02-01 UL 1897 2012 PRI Construction Materials Technologies (rST5878) OCF-355-02-01 UL 1897 2012 'Determined to be equivalent to ASTM D 226-09, Type I and II This evaluation report is provided for Stale of Florida product approval under Rule 61 G20.3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation repon does not express nor Imply warranty, installation, recommended use, or other product alldbutes that are not specifically addressed herein. CREEK OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock® Self -Sealing Ice & Water Barriers TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION AND LIMITS OF USE Weatherl-ock(D G WeatherLock® G is an ASTM D 1970 self-adhesive undedayment constructed from SBS (Brentwood, NH) modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2-sq. roils with nominal dimensions of 3-ft x 66.7-ft. WeatherLock® G is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock® Mat WeatherLock® Mat is an ASTM D 1970 self-adhesive undedayment constructed from (Brentwood, NH or SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1- Houston, 7X) sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock® Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock® Metal WeatherLock® Metal is an ASTM D 1970 self-adhesive undedayment constructed from (Brentwood, NH) SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The product is supplied in 2.0 sq. rolls with nominal dimensions of 3-11 x 66.7-ft. WeatherLock® Metal Is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on. the roof deck shall be limited to a maximum 90 days. WeatherLock® WeatherLockC1 Specialty Tile & Metal is an ASTM D 1970 self-adhesive undedayment Specialty Tile & Metal constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric. (Brentwood, NH or The product is supplied in 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-ft. Houston, 7X) WeatherLock® Specialty Tile & Metal is permitted to be used as prescribed in FBC Section 1507.1.1. WeatherLock® Specialty Tile & Metal is permitted to be used with adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160 (ICP Adhesives and Sealants, Inc.) or TILE BOND Roof Tile Adhesive (The Dow Chemical Company). Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when used with clay or concrete tile installations without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per stack. WeatherLock® G (High WeatherLock® G (High Tear) is a selfadhered, undedayment used as an alternative to Tear) ASTM D 226, Type I or Type II roofing felt and ASTM D 1970 self -adhering polymer (Houston, 7X) modified bitumen underayment. The undedayment is composed of SBS modified asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal dimensions of 3-ft x 65-ft. WeatherLock® G (High Tear) Is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days. c, oiwu uuWy l Mccn Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC PRODUCT APPLICATION Min. Roof Slope: Application: Min. Application Temperature: RESISTANCE 2:12 in accordance with the FBC OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock® Self -Sealing Ice & Water Barriers All undedayments shall be installed in accordance with the FBC. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underiayment application. Prior to beginning Installation, the undedayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The undedayment shall be installed with the release backer removed and pressed firmly into place to ensure complete contact with the deck. The undedayment shall be installed with the roll length parallel to the eave, starting at the save, and with minimum 3" side laps and minimum 6" end laps staggered min. 6-ft.from preceding course. Additionally, if applying WeatherLock® Specialty Tile & Metal, end laps shall be primed with ASTM D 41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width of the lap. It is permissible to back nail the undedayment 12-inches on -center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the undedayment). Additionally, WeatherLock® Specialty Tile & Metal shall be back nailed when installed on roof slopes greater than 3:12. 40°F; Contact the manufacturer when installing at temperatures below the minimum application temperature. The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. Undedavment System No.1 — WeatherLock Specialty Tile & Metal Only Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24" o.c. Undedayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with manufacturer's installation instructions to the fastened deck and backnailed along the selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through optionally primed, 32ga. x 1-5/8-inch 0 tin caps spaced 12" o.c. The applied underlayment shall be rolled with a minimum 751b steel roller immediately following application. Maximum Design -142.5 psf Pressure: OCR14002.8a FL9777-RI1 Page 3 of 4 This evaluation report is provided for Stale of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK OWENS CORNING ROOFING AND ASPHALT LLC WealherLockO Self -Sealing Ice & Water Barriers TECHNICAL SERVICES, LLC „ GENERAL LIMITATIONS 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturers published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deck area shall be property ventilated in accordance with the FBC requirements. 6) All side lap seams shall be installed to shed water from the deck. 7) The underlayment may be used as described in other current FBC product approval documents. 8) Design wind load pressures shall be determined for components and cladding In accordance with FBC 1609. 9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind load pressures fo(components and cladding. 10) Maximum Design Pressures for a given undedayment shall meet or exceed the design wind loads determined for the roof assembly. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 6"' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. O0 11% 1 11 fill $,, ....... ..�.10 r.•� NF� 2Q9 7.q Q. `,C. ,•VV No 74021 _ _ - 09:06:29 — 041QQr 9, STATE OF ',tt/� �i�CCs •; O 10: 'GN Zachary R. Priest, P.E. R �p Florida Registration No. 74021 Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial Interest in any company manufacturing or distributing products under this evaluation. Zachary R- Priest, P.E. does not have, nor will acquire, a financial interest In any other entity involved in the approval process of the product END OF REPORT OCR14002.88 FL9777-Rl l Page 4 of 4 This evaluation report Is provided for State of Florida product approval under Rule 61G20.3. The manufacturer shall notify CREEK Technical Services, LLC of any productchanges or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.