Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION • Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, \` 'S\� Permit Number: Owner: lk G Jurisdiction: Design Location: FL, Fort Pierce / County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft' b. Frame - Wood, Adjacent R=11.0 192.00 112 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1474.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1474.00 ft2 6. Conditioned floor area above grade (ft) 1474 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R 112 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 300 a. U-Factor: Sgi, U=0.63 101.25 ft2 SHGC: SHGC=0.25 b 40.00 ft2 12 ms SCA/ Efficiency SHGC: SHGC 0.21 a. Cent al Uniting /VAA®kB34 8r SEER:15.00 13 C4systems C/g C�OVUnh.Btuihr Efficiency d. U-Factor: N/A ft a. Electric Heat Pum�t 34.8 HSPF:8.50 `Y SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.239 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1473.5 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2 b. Conservation features b. N/A R= ft2 None c. WA R= ft2 15. Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 48.34 PASS Total Baseline Loads: 48.53 1 hereby certify that the plans and specifications covered by Review of the plans and Srgls this calculation are in compliance with the Florida Energy specifications covered by this 04THE Code. calculation indicates compliance y ,i„�O+jz `` .o �O with the Florida Energy Code. un, •t", .:' +"°;:• "`n PREPARED BY: Before construction is completed v. DATE: this building will be inspected for compliance with Section 653.908 �yjp a I hereby certify that this building, as designed, is in compliance Florida Statutes. !,Y with the Florida Energy Code. COp W'B,V0 OWNER/ Cz NT� C , BUILDING OFFICIAL: DATE: N \ DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4. F1itg_ Elaf(j ` I Pagel of 5 W7•,IZIIb-SailVA PROJECT Title: WYNNE THE STERLING Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE STERLING Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 329 ft- — 0 1 0 2SIab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft2 __ 0 1 0 3 SIab-On-Grade Edge Insulatio M. BATH 8 ft 0 56 ft' _- 0 1 0 4SIab-On-Grade Edge Insulatio KITCHEN 1ft 0 192 ft' ____ 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' ____ 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft' ___ 0 1 0 7 SIab-On-Grade Edge Insulatio ENTRY 7 ft 0 55 ft' — 0 1 0 4/17/2018 2:37 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile. Wood Carpet ' 8SIab-On-Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft' --__ 0 1 0 9SIab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft' 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1553 ft' 246 ft' Light 0.6 No 0.9 No 0 18.4 ATTIC / V IRCC # Type Ventilation Vent Ratio (1 in) Area RBS 1 Full attic Vented 150 1474 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 329 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood _ 3 Under Attic (Vented) M. BATH 30 Blown 56 ft° 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft' 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft' 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft' 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft' 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft' 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft' 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _1 NE=>SW,Exterior Concrete Block -Ext Ins®EDROOM 4.1 10 0 8 0 80.0 ft' 0 0 0.6 0 _ 2 SW=>NE Exterior Concrete Block - Ext Insi3EDROOM 4.1 28 0 8 0 224.0 ft' 0 0 0.6 0 _ 3 NW=>SE Exterior Concrete Block - Ext Insi0EDROOM 4.1 14 0 8 0 112.0 ft' 0 0 0.6 0 _ 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft' 0 0 0.6 0 5 NE=>SW Exterior Concrete Block -Ext Insul BATH 4.1 5 0 8 0 40.0ft 0 0 0.6 0 6 NE=>SW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 16 0 8 0 128.0 ft' 0 0 0.6 0 7 SE=>NW Exterior Concrete Block - Ext In!affDROOM 2 4.1 10 0 8 0 80.0 ft' 0 0 0.6 0 8 S=>N Exterior Concrete Block - Ext InfiffDROOM 2 4.1 4 3 8 0 34.0 ft' 0 0 0.6 0 _ 9 SW=>NE Exterior Concrete Block - Ext InfiffDROOM 2 4.1 2 0 8 0 16.0 ft' 0 0 0.6 0 10 SE=>NW Exterior Concrete Block- Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft' 0 0 0.6 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft' 0 0 0.6 0 12 SW=>NE Exterior Concrete Block - Ext InsdIAUNDRY 4.1 6 0 8 0 48.0 ft' 0 0 0.6 0 _ 13 NE=>SW Exterior Concrete Block - Ext InsGREAT/DINI 4.1 26 0 8 0 208.0 ft' 0 0 0.6 0 14 NW=>SE (Exterior Concrete Block - Ext Ins©REAT/DINI 4.1 20 0 8 0 160.0 ft' 0 0 0.6 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft' 0.23 0.6 0 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 DOORS # Omt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW 13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 0.63 0.25 N 32.9 ft' 1 ft 0 in 1 ft 4 in 0.63 0.25 N 6.9 ft' 1 ft 0 in 1 ft 4 in 0.63 0.25 N 24.0 ft' 6 it 0 in 1 ft 4 in 0.63 0.25 N 37.5 ft' 1 ft 0 in 1 ft 4 in 0.65 0.21 N 40.0 ft' 8 ft 0 in 1 ft 4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft' 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1375.7 75.53 142.04 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 Fnph4 Rdf1F-9M7 DUCTS / -- Supply ---- --- Return -- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 300 ft' Attic 75 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programabl[e Y Ceiling Fans: an HeDec ating [X] Jan Feb [[ [X� Mar [ ] [ ] [ May[[ ] ]] LX] Jun [[ ]] [X1 Jul [ ] Aug [[ ]] [X] Sep �[ ]]] Octet [rX'] NovrrX]� Nov Venting [[ ]) Jan [ Feb l J [[X11 Mar [X] APf [) Mey [[ J) Jun [[ ]) Jul EX] 1 Aug [[ ]) Sep lhl lxl [X] [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 so 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 .2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and an gaps in the air barrier shall be sealed. Y 9 P shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Dud shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots WAG register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire snrinkler cover plates and walls or ceilinas a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 4/17/2018 2:38 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 .FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. THE STERLING, FT. PIERCE, FL, 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft' 7. Windows" Description a. U-Factor: Sgl, U=0.63 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 SHGC: SHGC=0.21 c. U-Factor. N/A SHGC: d. U-Factor. N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1260.00 ft' b. Frame - Wood, Adjacent R=11.0 192.00 ft' 1 c. N/A R= ft' 2 d. N/A R= ft' Yes 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 1474.00 ft' 1474 b. N/A R= ft' Area c. NIA R= ft. 101.25 ft' 11. Ducts R ft' a. Sup: Attic, Ret: Attic, AH: Attic 6 300 40.00 ft' 12. Cooling systems kBtu/hr Efficiency ft' a. Central Unit 34.8 SEER:15.00 ft' 13. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 34.8 HSPF:8.50 3.832 ft. 0.239 Insulation Area R=0.0 1473.50 ft' R= ft' R= ft' 14. Hot water systems a. Electric Cap: 40 gallons EF: 0.97 b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. ^ �/ Builder Signature: Date: Address of New Home: City/FL Zip 3 �-A5 52 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 - wrightsoft° Project Summary Date: Entire House By: QUICK.CALCS, INC. 317 ST. LUCIE LM. FT. PIERCE, FL 34946 Phone; 772-46"799 Fax 772-46"796 Email: OUICKCALCSQAOLCOM Project• • For. WYNNE DEVELOPMENT THE CARLTON`299, FT. PIERCE, FL Notes:\�C� l�. �O 9 Weather. Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TO 28 OF Heating Summary Structure 18188 Btuh Ducts 5654 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 23842 Btuh Infiltration Method Construction quality Fireplaces Fort Pierce, FL, US Simplified Average He 1474 Co Area ft 2 1474 Volume (W) 12227 12227 Air chargeslhour 0.45 0.23 Equiv. (cfm) 92 47 'Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A`030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual', air flow Air flow factor Static pressure Space thermostat Capacity balance point = 33 OF 8.5 HSPF 34600 Btuh @ 47°F 27 OF 1160 cfm 0.049 afm/Btuh 0.50 in H2O Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TO 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 17877 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0. Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier Equlpmenf sensible load 0.95 26093 Btuh Latent Cooling Equipment Load Sizing Structure 2958 Btuh Ducts 2319 Btuh Central vent (0 cfm) 0' Btuh (none) Equipment latent load 5277 Btuh Equipment total load 30370 Btuh Req. total capacity at 0.70 SHR 3.0 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536MO30 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Stuh Total cooling 34800 Btuh Actual. airflow 1160 cfm Air flow factor 0.044 cfm/Stuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Wrightsoft' Right -Suite® Uniwrsal 2017 17.0.14 RSU08101 2017-Apr-1017:14:53 '��...Wrightsoft WVAC\WYMJE-THE GRAND CARLTON-299.rup Calc=MJB Front Door faces: N Pagel wrightsoft' RighW@ Worksheet Job: Entire House Date` QUICK CALCS, INC. By 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-4666799 Fax 772-4666796 Emil: OL4CKCALCS@AOLCOM 1 Room name Entire House BEDROOM 2 Exposed wall 156.2 ft 52.0 ft 3 Room height 8.3 If d &0 It heat/cool 4 Room dimensions 1.0 x 329.0 ft 5 Room area 1473.6 ft' 329.0 IF Ty Construction U-value Or I HTM Area (ft') Load Area (ft2) Load number (BluNflx'F) (Btuwftl or perimeter (ft) (Stub) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/s Heat Cool 6 rt/I�✓— 13A-0dcs 0.143 .no 4.00 . 255 479 442 1768 1123 80 80 320 .;.204 I`D—f' •, INclorn11 0:� 38 .0 .0 ., .. 1331 i2210 - ` o 0 0 .'0 138 331 210 0 0 0 0 C�'.- �13DD5 se o:0 Z 55 24 48 848 829 0 0 0 0 ' 22 22 236 244 0 0 0 0 W 434-0cds 0.143 :a 4:00 . 255 34 34 136 -86 0 0 0 - 0 W I— la&-4ws 0.143 sw 4.00 255 360 353 1414 899 224 224 897 570 1Aclom 1.270 sw 3556 42.91 7 11 247 298 0 0 0 0 .G yl, _ I�-CG 13A4ocs .0.143 nw, 4.00 2.55 . 290 217 867 .. 551 112 - 79 318 202 1Acicrn - 1:270 nw 35.56 :45.24 33 - 0 1162 1478 . -33 '; '0 1162 .' 4A5i-20M -.- ,.0.770 ' nw , 21.56 . '27.54 41 0 880 . • • 1124 0 0 • 0 .1478 • 0 P 12C41sw 0.091 - 2.55 1.28 192 192 489 246 0 0 0 _ 0 C .16A30md 0.032 - 0.90 232 1474 1474 1320 . 3419 329 329 295 763 F 22Ata 0.989 27.69 0.00 1474 156 4325 0 329 52 1440 0 6 c)AED excursion 784 1 680 Ewlope loss/gain 15366 13954 4432 3897 12 a) Infiltration 2822 T73 909 249 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 1160 2 460 Appliances/other 20DO 0 Subtotal pines 6 to 13) 18188 17877 5341 4606 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 14 Subtotal 18188 17877 5660 6 15 Duct loads 31% 48% 8536 31% 48% 1660 2199 2199 Total room load f23842 26413 700t 6805Air required (cfm) 116101 341 299 Calculations approved byACCA to meet all requirements of Manual J 8th Ed .A wrightsofC• 2017-Apr-1017:14:53 RGRAND A Universal 9.nu 17Cato RWit F1 Page 1 ...Wdghisoft HVAC1WYNNE-THE GRAND CARLTON-299.mp CaIc=MJB Front Door faces: N F wrightsoft Right-JO Worksheet Job: Enure House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LPL, FT. PIERCE, FL 34946 Phone: 772-46"799 Fax 772-466-6796 Emil: OUICKCALCS@AOL.COM 1 Room name WIC M. BATH 2 Exposed well 0 ft 8.0 If 3 Room height 8.0 it heat/cool 8.0 ft heat/cool 4 Room dimensions 7.0 x 9.0 ft 7.0 x 8.0 ft 5 Room area 63.0 ft2 56.0 It. Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (BtuWfti-F) (Btuh/ft2) or perimeter (ft) (Btuh) a perimeter (ft) (Stuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat cool 6 Vf13A-4ocs ' 0143 ; ne. 4.06 .2.65 -0 0 r 0 ,. 0 0 , 0 0 . 10 LGI IA-ctonn J270 .ne' '35.56' .70.43-.. 0 0.,, 0 0 0 ,..0 :0' i-0 YI}--(; 13A-4ots 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 1Actom 1.270 as 35.56 34.77 0 0 0 0 0 0 0 0 11 LD 11130 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W - 13A4ocs: 0.143 's 4.00 2.55 0 .0 0 0 -0 0 0 0 W 13A-0acs 0.143 sw 4.00 255 0 0 0 0 _ 64 57 228 145 L-G 1A of m 1.270 sw 35.66 42.91 0 0 0 0 7 5 247 298 13A46cs -`, .. - - 0.143 nw - 4 00 2:56 0 - 0 O 10 0 ' 0 0 ' 0 lklom 1.270 my 3556 45.24 :0 -0... 0' 0 0 :. .0. 0 ,,,0 4A.5.2om . :0.770 nw - .. ` 21.56 '27.54 0 ' 0 '' 0 0 0 • 0 0 .• ` . 0 P 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 0 0 0 0 C 164-30md 0.032 - 0.90 232 63 63 56 146 56 56 60 130 F 22A-tpl 0.969 - 27.69 0.00 63 0 0 0 56 8 222 0 6 c)AED excursion 1-2 225 Penelope lassfgain 56 145 747 798 12 a) Infiltration 0 0 140 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Oines 6 to 13) 56 145 887 836 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 145 887 836 15 Duct loads 31% 48% 18 69 31% 48% 276 399 Total room load 74 214 1162 1235 Air required (rim) 4 9 57 54 Calculations approved byACCA to meet all requirements of Manual J 8th Ed -F'.F wrightsof't- RlghtSulte® Universal 2017 17.0.14 RSUD8101 2017-AprA0 17:14:53 �� ... Wrightsoft HVAC1WYNNE-THE GRAND CARLTON-299.mp Cale =MJ8 From Door faces: N Page wrightsoft- Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By- 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-46"796 Email: QUICKCALCS@AOLCOM 1 Room name KRCHEN BATH 2 3 Exposed wall Room height 0 It 8.0 It heat/cool 5.0 ft 8.0 It heallcool 4 5 Room dimensions Room area 1.0 x 192.0 It 192.0 fP 9.0 x 5.0 It 45.0 ft- Ty Construction U-value Or H-rM Area (fl2) Load Area (ft� Load number (9twft-°F) (Btuwfn or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIRIS Heat Cool Gross WP1S Heat Cool 6 t�1 ��. G 13A4ocs ' 0.143 no 4.00 - 2.65 0 0 0 . .0 •. 40 .40 160 � 102 AAclom, 1.270 ne { *35.56 4 70.43 . 0 . '. ' .0 . , 0 ... 0 0 " .0 - ' 0 "'r.. • 10 v 13A-4ocs 0.143 as 4.00 255 0 0 0 0 0 0 0 �0 11 I-G II-----0-0 1Ac1om 11DO 1.270 0.39D se se 35.56 10.92 34.77 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 a 0 ,w. - . W ',.iak4 ds 13A-4cbs 0.143 0.143 s sw - .4.00 4.00 2.55 255 0 0 0 0 - 0 0 . 0 0 0 0 0 0 0 0 0 0 1Aclom 1.270 sw 35.56 42.91 0 0 0 0 0 0 0 0 Vj�• 13AAom 1Aclom.' - .. ; M143. 1.270 m-. nw: 400 • 3556 2.55 ' 45.24. - 0' 0 0 0: 0 0 0 10,- - 0 0 ': 0 '0" 0 0 :;0 ,; 0 . 4A5-2orn ,0.770 nw ,. 21.56 :27.54 0 0 0 11 o •0 0. 0 P C. 12C Gsw 16A30md 0.091 0.032- - 2.55 0.9D 1.28 232 64 192 64 192 163 172 82 445 0 .45 0 -.45. 0 40 0 104 F 22A4p1- 0.989 - 27.69 0.00 192 0 0 0 45 5 138 0 6 c)AED excursion -27 -2 Envelope lossfgain 335 501 339 204 12 a) Infiltration 0 0 87 24 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2000 0 Subtotal Qines 6to 13) 335 2501 426 228 14 15 Less eldemal load Less transfer Redistribution Subtotal Ductloads 31% 48% 0 0 D 335 104 0 0 0 2501 1194 31% 48% 0 0 0 426 133 0 0 0 228 109 Total room load Air requiretl (cfm) 439 21 3695 162 559 27 338 15 Calculations approved byACCA to meet all requirements of Manual J 8th Ed .fc& 4• wrights ft- RlghtSuite® Universal 2017 17.0.14 RSUD8101 2017-Apr-1017:14:53 ...Wdghtsoft HVACIWYNNE-THE GRAND CARLTON-299.mp CaIc=MJB Front Door faces: N Page 3 wrightsofr Right-M Worksheet Job: Entire House oyes: ey- QUICK CALCS, INC. 317 ST. LUCIE UN., FT. PIERCE, FL 34946 Phone: 77246M799 F= 77246"796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM ENTRY 2 =ad wall 32.2 ft 7.0 ft 3 Room height 8.0 ft heat/cool 8.0 It hest/cool 4 Room dimensions 1.0 x 203.5 ft 1.0 x 55.0 ft 5 Room area 203.5 ft' 55.0 ft- Ty Construction U-value Or HTM Area Load Area I Load number (Btuh/ftMF) (BtttNft2) a perimeter (ft) (Btuh) or perimeter (ft) (Burn) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 Vy 13A-4ws : 0.143 :'..he :no 4,00 2.55 128 128 513 . 326 - . 0 0 0 .0 :1A 1dm. _ 1.270 35.66 70.43 0'. 0 . • 0 :..0 . . 0 0 .. 0 . .'' 0 4)I 13A-4ws 0.143 se 4.00 2.55 80 56 225 143 48 26 106 67 IL-GD 1Aclom 1.270 se 35.56 34.77 24 24 948 829 0 0 0 0 11 11D0 0.390 se 10.92 11.31 0 0 0 0 22 22 236 244 W. •13A4ocs 0.143 -•s .4.00 255 34 34 136 a6 0 0 ..0 0 48 I-G 13A4ocs 0.143 sw 4.00 2.55 16 16 64 41 8 8 32 20 1Aclom 1.270 sw 35.56 42.91 0 0 0 0 0 0 0 0 13AAocs 0.143 nw 4.00 .:2.55 0 , 0 0 .0 ' 0 0 0 -' 0 1Aclom 1.270;nw.. 35.56 45.24-._ 0,., 0 0 0 0 0. . 0..,. ''o :4A5.2om 0.770 nw 21.66 27.54 0- 0 0. 0 0 0'. 0 0 P 1213-0sw 0.091 - 2.55 1.28 0 0 0 0 72 72 183 92 C "16A-30md 0.032 - 0.90 232 204 204 182 472 55 65 49 128 F 22A4PI 0.989 - 27.69 0.00 204 32 891 0 55 7 194 0 6 c)AED excursion -24 -6 Envelope loss/gain 2859 1873 800 545 12 a) Infiltration 564 154 122 34 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal (fines 6 to 13) 3422 2257 Sm 679 Less eldemel load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3422 257 922 579 15 Duct loads 31 % 48%1 1064 1078 31% 48% 287 276 Total room load 4486 3335 1209 855 -required(cfm) 218 146 59 38 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �A WrighiSofY Right-Suile® Universal 2017 17.0.14 RSU08101 2017-Apr17:14:53 ...Wrightsoft HVAC1WYNNE-THE GRAND CARLTON-299.mp Cale =MJB Front Door faces: N Page 4 + wrightsoft• Right-M Worksheet Job: Entire House Date: ay. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOLCOM 1 Room name LAUNDRY GREATIDINNG 2 Exposed wall 6.0 ft 46.0 ft 3 Roam height 8.0 it heWcool 8.9 It heat/cool 4 5 Room dimensions Room area 7.0 x 6.0 it 42.0 ft- 1.0 x 488.0 ft 488.0 W Ty Construction U-value Or HTM Area (ft' Load Area (fly Load number (BtuNfP-°IF) (BIUNft) or perimeter (it) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 .V7/ L'-G 13A-4ccs. • .1A-c1 m 13A4ocs '0143 .� -1%270 0.143 '.no no se _ 4.00 .-�'35.56 4.00 2.55 "..70.43 255 0' 0 0 0 • 0. 0 0, ... 0 0 0 0:' 0 231 38 0 ` 784 , . 0 0 775 1344 0 493 ' 2662 0 W 11 I{--GD 1Actom 11DO 1.270 0.390 as as 35.56 10.92 34.77 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W Vd Y-G '13AAccs 13Adacs 0.143 0.143 s . sw .4:00 4.00 255 255 0 48 .0- 48 0. 192 0 122 - 0 0 - 0 0 0 0 - ,0 0 1A-cl m 13A4ocs% 1Aclom-' '4A5-2om' 1270 .0143 1270 07.70 sw nw nw nw 35.56 . 400 :: 3556 - 21.56 42.91 2.55 • 45.24 ..27.54 0 - 0, 0- 0 0 0. ,0 0 0 - 0 0 0 0 .0 -0' -0 0 178 0'; 41 0 137- , 0 - 0 0 549 - 0 880 0 - 349 "• -1 0 , 1124 W ---G P 12C-0sw 0.091 - 2.55 1.28 56 56 143 72 0 0 0 0 C .16A-30md 0.032 - 0.90 232 42 42 38 97 488 488 437 .1132 F 22A4p1 0.989 - 27.69 0.00 42 6 166 0 488 46 1274 0 6 c)AED excursion -3 !fi Envelope loss/gain 539 288 5259 5704 12 a) Infiltration 105 29 895 245 b) Room ventgation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 644 317 6154 6409 Less eMemal load Less transfer 0 0 0 0 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 644 317 6164 6409 15 Duct loads 31% 481/6 200 151 31% 48% 1913 3060 Total room load Air required (cfm) 8" 41 468 21 8Wi` 393 9469 416 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ,,g& -F[J- wrllghtsoft- RlghtSuite@ Universal 201717.0.14 RSUD8101 2017-ApM0 17:14:53 5 ...WdghtsoR WAC1WYNNE-THE GRAND CARLTON-299.mp Cale =Md8 Front Door faces: N g WlrightsOft Duct System Summary Job: y Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772d666799 Fax 7724666796 Email:. OUICKCALCS a[1AOLCOM P'roject Intormation Far. WYNNE DEVELOPMENT THE CARLTON 299, FT. PIERCE, FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply / return available pressure 0.250 / 0.250 in H2O 0.250 / 0.250 in H2O Lowest friction rate 0.284 in/100ft 0.284 in/100ft Actual air flow 1160 cfm 1160 Cfm Total effective length (rEL) 176 ft Name Design (Btuh) Htg (Cfm) Clg (Cfm) Design FIR Diam (In) H x W (In) Duct Mati. Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 559 27 15 0.376 4.0 OxO VIFx 18.1 115.0 st1 BEDROOM In 4486 218 146 0.374 6.0 OxO VIFx 18.6 115.0 st1 BEDROOM -A h 3501 170 149 0.297 6.0 OxO VIFx 33.1 135.0 st2 BEDROOMS h 3501 170 149- 0.284 6.0 OxO VIFx 41.1 135.0 - st2 ENTRY h 1209 59 38 0.510 4.0 OxO - VIFx 3.0 95.0 GREAT/DINING c 4735 196 208 0.318, 7.0 0x0 VIFx 22.4 135.0 st2 GREAT/DIMNGS c 4735 196 208 0.307 7.0 OxO VIFx 28.1 135.0 st2 KITCHEN c 3695 21 162 0.375 7.0 OxO VIFx 18.3 '115.0 st1 LAUNDRY h 844 41 21 0.366 6.0 OxO VIFx 21.6 115.0 st1 M,RATH h 1162 57 54 0.366 4.0 0x0 VIFx 21.6 115.0 st1 WIC C 214 4 9 1 0.310 1 4.0 Ox0 I VIFx 26.3 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (Cfm) FIR (fpm) (in) (In) Material Trunk st2 Peak AVF 737 724 0.284• 689 14.0 0 x 0 VinlFlx st1 st1 Peak AVF 1101 1122 0.284 804 16.0 0 x 0 VinIFIX L + wri htsofY 2017-Apr-1017:14:54 ACM9 RigMSuiteW Universal 2017 77.0.14 RSU08101 ...WrIghtsoe WAC\WYNNE-THE GRAND CARLTON-299.mp Cato = MJ8 Front Door faces: N Page 1 Return Branch Detail Table Name Grille Size (in) Htg (Cfm) Clg (Cfm) TEL (ft) Design FIR Veloc (fpm) �Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matt Trunk rb1 OXO 1160 1160 0 1 0 0 0 Ox 0 1 VIFx q, {J�} Wrl htsoft' 2017-Apr-1017:14:54 �� ' f Right -Suite® Universal 2077 17.0.74 RSU08101 ...Wrightsoft WAC\WYNRE-THE GRAND CARLTON-299.rup Cale =MJ8 Front Door faces: N Page 2