HomeMy WebLinkAboutBLOWER DOOR TEST CERTIFICATEPlanning & Development Services
Building & Code Regulation Division
O t j 2300 Virginia Ave, Rm 201
' '4C Fort Pierce, FL 34982
-,Y Phone:772-462-2165 Fax:772-462-6g43
Date: y f " (( l
Contractor.
.lob Address
B0,091)i'ER DOOR TEST FORM
House infiltration Test Certification
Prescriptive and Performance Method
ra
L�'la
o3S7
RECEIVED
AUG 2 01019
Permitting Depart
St. Lucie C,,,, menr
SCANNED
Permit #: ( 81 2- - 0,3 S '? Be County u
Construction: "mew Construction — Complete ( ) Existing — After Addition
House Infiltration Test Results SLC Climate Zone 2 p/� r/Q
CFM (50) = 1319 T est Date: 0 / oI
Volume = ! 1 -7 91
ACH (50) = CFM (50) it 60 / Volume = �- Mechanical Ventilation required less than 3 ACH
Passing results must be & ACH (30) or less (114 Pass ( ) Fail
FBC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (1) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at anytime after creation of all penetrations of the building
thermal envelope.
F6C, F:esiderecial
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Company
Company Name: Pro -Duct Services
Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section R402.4.1.2 Climate Zone 2.
Signature: G /X i
Printed Name: Martin Klein
License/Certification #: 5061633
Planning Os Development services
Building Code Regulation Division
2300 Virginia Ave, Rm 202
Fort Pierce, FL 34932
Phone:772-462-2155 Fait:772-462-6443
RECEIVED
SEP 0 9 71118
Permitting Departrn: ,
St. Lude Caur�
SLOWER DOOR TEST FORM
S
House Infiltration Test Certification St C,q��
Prescriptive and Performance Method 41,0�BY F,
f C
Date: Permit#i: _ (8 12 — 03S'7 111)61
Contractor. _ (/�, n �� fie,, .r _ _ s_.1,
Job Address: 3 Lo F G, I0-S g PL 3 tF `t S2
Construction: �niew Construction — Compete ( ) Existing — After Addition
House Infiltration Test Results SLC Climate Zone 2 f
CFM (50) = 1-3/9 P
volume = / 1 -i 9 2 est Date: / Z Ohl
/ q
ACH (50) = CFM (50) it 60 / Val ume= �- Mechanical Ventilation required less than 3ACH
Passing results must be & ACH (50) or less (14 Pass ( ) Fall
FIX, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour In Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either Individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
F9C, Racidwrumi
Where the air infiltration rate of a dwelling unit Is less than !.air changes per hour when tested with a blower door at a
Pressure of 0.2 Inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
i estine Comnanv
Company Name: Pro -Duct Services
Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements In accordance with SeAlon R402.4.1.2 Climate Zone 2.
Signature:
Printed Name: Martin Klein
License/Certification #: 5061633