Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business arid Professional Regulation - Residential Performance Method Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. P\IER.C.�E , FL, Permit Number: Owner: 3 ib �' Jurisdiction: Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft' b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1474.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1474.00 ft2 6. Conditioned floor area above grade (ft2) 1474 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 300 a. U-Factor: Sgl, U=0.63 101.25 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft2 12. Cooling systems Sl kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit C ^, 34.8 SEER:15.00 c. U-Factor. N/A ft2 SHGC: 13. Heating systems C�0 TtBlu/hr Efficiency d. U-Factor. N/A ft2 a. Electric Heat Pump CO, 34.8 HSPF:8.50 SHGC: / Area Weighted Average Overhang Depth: 3.832 ft. J� Area Weighted Average SHGC: 0.239 14. Hot water systems 8. Floor Types (1473.5 sgft.) Insulation Area a. Electric Cap: 40 gallons a. a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft' 15. Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 48.34 PASS Total Baseline Loads: 48.53 1 hereby certify that the plans and specifications covered by Review of the plans and S7gl� this calculation are in compliance with the Florida Energy specifications covered by this O�TFIE Code. calculationnce tFlorida with the Energy Code. PREPAR By. Before construction is completed DATE: this building will be inspected for,-v y compliance with Section 553.908 t I hereby certify that this building, as designed, is in compliance Florida Statutes. !� with the Florida Energy Co SOD WE OWNER(AG�f�T� BUILDING OFFICIAL: DATE: \ d \'�` DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILI;r Z B pY 4/17/2018 2:37 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: WYNNE THE STERLING .Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE STERLING Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M. BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 329 ft- — 0 1 0 2 Slab -On -Grade Edge Insulatio WIC t ft 0 63 ft' — 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft' ___ 0 1 0 4Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 192 ft' ____ 0 1 0 SSIab-On-Grade Edge Insulatio BATH 5 ft 0 45 ft' ____ 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft' -_ 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft' — 0 - 1 0 4/17/2018 2:37 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6 CnDKA PAnr7AfN7 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio 'LAUNDRY Eft 0 42 ft' ---- 0 1 0 9SIab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft' ---- 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1553 ft' 246 ft' Light 0.6 No 0.9 No 0 18.4 ATTIC / V IRCC # Type Ventilation Vent Ratio (1 in) Area RBS 1 Full attic Vented 150 1474 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ 1 Under Attic (Vented) BEDROOM 30 Blown 329 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63ft' 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft' 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft' 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft' 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft' 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft' 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo w Space _ 1 NE=>SW Exterior Concrete Block - Ext InsiREDROOM 4.1 10 0 8 0 80.0 ft' 0 0 0.6 0 _ 2 SW=>NE Exterior Concrete Block - Ext InsiREDROOM 4.1 28 0 8 0 224.0 ft' 0 0 0.6 0 _ 3 NW=>SE Exterior Concrete Block - Ext InsdiIEDROOM 4.1 14 0 8 0 112.0 ft' 0 0 0.6 0 . 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft' 0 0 0.6 0 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.6 0 _ 6 NE=>SW Exterior Concrete Block - Ext InSEDROOM 2 4.1 16 0 8 0 128.0 ft' 0 0 0.6 0 7 SE=>NW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 10 0 8 0 80.0 ft' 0 0 0.6 0 8 S=>N Exterior Concrete Block - Ext InfiffDROOM 2 4.1 4 3 8 0 34.0 ft' 0 0 0.6 0 9 SW=>NE Exterior Concrete Block - Ext InOEDROOM 2 4.1 2 0 8 0 16.0 ft' 0 0 0.6 0 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft' 0 0 0.6 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft' 0 0 0.6 0 12 SW=>NE Exterior Concrete Block- Ext InsdIAUNDRY 4.1 6 0 8 0 48.0 ft' 0 0 0.6 0 13 NE=>SW Exterior Concrete Block - Ext InsGREAT/DINI 4.1 26 0 8 0 208.0 ft° 0 0 0.6 0 14 NW=>SE Exterior Concrete Block - Ext Ins 3REAT/DINI 4.1 20 0 8 0 160.0 ft' 0 0 0.6 0 15 N=>S .Garage Frame - Wood KITCHEN 11 24 8 192.0 ft' 0.23 0.6 0 4/17/2018 2:37 PM EnergyGaugeS USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R4n5-9017 DOORS # Omt Door Type Space Stones U-Value Ft Width In Ff eightln Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. _ / Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 0.63 0.25 N 32.9 ft' 1 It 0 in 1 ft 4 in 0.63 0.25 N 6.9 ft' 1 It 0 in 1 ft 4 in 0.63 0.25 N 24.0 ft' 6 It 0 in 1 ft 4 in 0.63 0.25 N 37.5 ft' 1 It 0 in 1 it 4 in 0.65 0.21 N 40.0 ft' 8 It 0 in 1 it 4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 316 ft' 24 it 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1375.7 75.53 142.04 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft, 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 Ff1RM RAm-W)17 DUCTS — Supply — — Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 300 ft' Attic 75 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y CApr[[eiling Fans:Cooling Jan Vent Jan Feb Feb Mar [f ] Apr May Jun [[ ]] [X] Jul f[[ ]] Aug [ ] Sep [ ] L Oct No f[X Nov r[X'j Dec ng l [ lxl Jun [)Jul I Aug LXl Ex] ]Sep _l lxl [X� [ ] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 2617 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind nin'no and wirino Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire qnrinkler cover nlates and walls or ca linas a. in aaamon, inspection of log walls small be in accordance with the provisions of ICC-400. 4/17/2018 2:38 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 'FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. THE STERLING, FT. PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 1474.00 ft2 6. Conditioned floor area (ft2) 1474 b. N/A R= ft2 7. Windows" Description Area c. N/A R= ft2 a. U-Factor: Sgl, U=0.63 101.25 ft2 11. Duds a. Sup: Attic, Ret: Attic, AH: Attic R ft2 6 300 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft2 SHGC: SHGC=0.21 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 34.8 SEER:15.00 SHGC: d. r: N/A ft2 SHGC: SHGC: 13. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.832 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.239 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2 a. Electric EF: 0.97 b. N/A R= ft2 c. N/A R= ft2 b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home:% lj Cg S City/FL Zip` S�r 'K>`, 3K4524, *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site of energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 wri htsoit® Project Summary SCBy Date: 9 Entire House St, Lucie®�n By: QUICK CALCS, INC. 317 ST. LUCIE Lk, FT. PIERCE, FL 34946 Phone: 772-466-6799 Pax 772-466-6796 Email: OUICKCALCS@AOLCOM Project• • For. WYNNE DEVELOPMENT THE CAAR\LTON 299, FT. PIERCE, FL Notes: � vQ) � IV c,� Design• • Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70. OF Inside db 75 OF Design TD 20 OF Design TO 15 °F Daily range Relative humidity L '50 6/e Moisture difference 61 gr/ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 18188 Btuh Structure 17877 Btuh Ducts 5654 Central vent (0 cfm) 0 Btuh Btuh Ducts . Central vent (0 cfm). 8536 0, Btuh Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23842 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 25093 Btuh Method simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2958 Btuh Ducts 2319 Btuh Central vent (0 cfm) 0 Btuh Heatingg Area Coolin�gg (none) (ft2) 1474 1474 Equipment latent load 5277 Btuh Volume (f 3) 12227 12227 Airchanges/hour 0.45 0.23 Equipment total load 30370 Btuh El AVF (cfm) 92 47 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment, Summary Cooling Equipment Summary Make Carrier Make Caner Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A•030 Cond 25HBC536A•030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 10440 Btuh Temperature rise 27 OF Total cooling 34800 Btuh Actual'airflow 1160 cfm Actual airflow 1160 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O balance Load sensible heat ratio 0.83 Capacthermostat point = 33 °F Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th,Ed wrightsoW RightSulte® Unhersai 2017 17.0.14 RSU08101 2017-Apr-1017:14:53 ��" " ...WdghtsoR HVAC\WYNNE-THE GRAND CARLTON-299.rup Cale =MJB Front Door ices: N Page 1 + wrightsafC Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE I.M. FT. PIERCE, FL 34946 Phone: 772466-6799 Fax: 772-466E796 Email: OUICKCALCS@AOLCOM 1 Rcom name Entire House BEDROOM 2 Exposed wall 156.2 ft 52.0 It 3 Room height 8.3 ft d 8.0 It heat/cool 4 Room dimensions 1.0 x 329.0 ft 5 Room area 1473.5 ft' 329.0 ft' Ty Construction U-value Or HTM Amp (flj Load Area (ftj Load number I (BtulVftz'F) (BtUWft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat cool Gross N/P/S Heat Cool 6 LG 13A'4ops -0.143 ,.ne -_ 4.00 2.55 479 .. 442 1768 1124 80 80 320 204 • .1Ac1om. 1.270 ne 35.56 -_70.43 ' 38 `0 '. 1344 2662..-0 0 ` 0..., ,.. '0 4y 13AAocs 0.143 se 4.00 255 128 83 331 210 0 0 -0 0 ��G 1Ac1om 1.770 se 35.56 34.77 24 48 848 829 0 0 0 0 11 D 11130 0.390 se 10.92 11.31 22 22 236 244 0 0 0 0 W ,13A-4= 0.143 s 4.00 255 34. 34 136 86 0 . 0 ` 0 0 W 13A ccs 0.143 sw 4.00 265 360 353 1414 899 224 224 897 570 �C 1Actom 1.270 sw 35.56 42.91 7 it 247 298 0 0 0 0 13A4ocs " -0.143 nw' . 4.00 2.55 '290 ' 217 - . , 867 . -551 -112 79. 318 202 . 1Aol m .: 1.270 nw .. 35.56 45.24 - 33 0 1162 .1478 33 . 0 '.. 1162 : ...1478 4A5-2om; 0.770 'mv ' 21.56 `-,'27.54 41 , 0 880. •. .,1124 0' 0 0:.. 0 P 12C-Dsw 0.091 - 2.55 1.28 192 192 489 246 0 0 0 0 C 'ABA-30md 0.032 - -0.90 2.32 1474 1474 1320 3419 329 329 295 763 i F 22MP1 0.989 - 27.69 0.00 1474 156 4325 0 329 52 1440 0 6 c)AED excursion 784 1 680 Envelope loss/gain 15366 13954 44321 3897 12 a) Infiltration 2822 773 909 249 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 5 1150 2 460 Appliances/other 2000 0 Subtotal(Iines 6to 13) 18188 17877 5341 4606 Less adwol load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18188 17877 5341 4606 15 Duct loads 31% 48% 6654 8536 31% 48% 1660 2199 Total room load 23842 26413 7001 6805 Air required (cfm) 1160 1160 341 299 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A - wrlghtsuft- Right-Sulte® Universal 201717.0.14 RSU08101 2017-Apr-10 17:14:53 ...Wrightsoft HVACIWYNNE-THE GRAND CARLTON-299.rup Cale = MJ8 Front Door faces: N Page 1 wrightsoft Right-J®Worksheet Job: Entire House Date: QUICK CALC$, INC. By. 317 ST. LUCIE LN. FT. PIERCE. FL 34946 Phone: 7724665799 Fas 772-466-6796 Email: DUICKCALCS@AOL.COM 1 Room name WIC M. BATH 2 ed wall 0 ft 8.0 ft 3 Room height 8.0 ft heat/cool 8.0 tt heat/cool 4 Room dimensions 7.0 x 9.0 It 7.0 x 8.0 ft 5 Room area 63.0 ft' 56.0 ft' Ty Construction U-value Or HTM Area Load Area number (Btuhlfti'F) (Btuwft') or perimeter (ft) (Btuh) or perimfeter (ft) (Stuh) Heat Cool Gross WP/S Heat Cool Gross WKS Heat cool 6 '13AAocs 0143"ne 4.00 2.55 0" "0 0 0 0 0 6 D L _G JAatoni 1.270-ne 35.56 70.43- 0 .0 0 0 0'' 0 0'.. "0 V� 13A-0acs 0.143 se 4.00 255 0 0 0 0 0 0 0 0 II----GD 1Aclom 1.270 se 35.56 34.77 0 0 0 0 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W 13A4ocs 0:143 s -4.00 255 0 0 0 0 D 00 . -0 Ly T-G 13A-0as 0.143 sw 4.00 2.55 0 0 0 0 64 57 228 145 1Acian 1.270 sw 35M 4291 0 0 0 0 7 5 247 298 VE13A4038 -., 0143 dw "niv 4.00 2.55 0 . 0 0 ;0 0 ... 0 0 .. `. U 1Aclorn --1270 35.56 45.24 0 " 0 , 0 0 , 0 -0 0 10 ' 4A5-2Dm'' +0.770 nw 21.56 27.54 0 0 1- 0 .0 0 - "0 ...0 - 0 P 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 0 0 0 0 c 16A90md 0.032 - 0.90 232 63 63 56 146 56 -56 50 130 F 22A-tpI 0.999 - 27.69 0.00 63 0 0 0 56 8 222 0 P. 6 c)AED excursion -2 225 Envelope loss/gain 56 145 747 798 12 a) Infiltration 0 0 140 38 b) Room vents ation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Dines 6 to 13) 56 145 887 836 Less a denial load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 145 887 836 15 Duct loads 31% 48% 18 69 31% 48% 276 399 Total room load 74 214 1 1162 1235 Airrequired (cfm) 4 g 671.64 Calculations approved byACCA to meet all requirements of Manual J 8th Ed -Fk wrightsoft- RlghtSuite® Universal 2017 17.0.14 RSU08101 2017-Apr-1017:14:53 ...Wdghtsoft FNACIWYNNE-THE GRAND CARLTON-299.rup Colo = MJB Front Door faces: N Page 2 i#f wrightsoft' Right-M Worksheet Job: Entire House Date: 8y: QUICK CALCS, INC. 317 SL LUCIE LK, FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-4666/96 Email: OUICKCALCS@AOLCOM 1 Room name KrrCHEN BATH 2 3 E)gmed wall Room height 0 it 8.0 it heaticcol 5.0 ft 8.0 It heatlocol 4 5 Room dimensions Room area 1.0 x 192.0 It 192.0 ft' 9.0 x 5.0 It 45.0 it' Ty Constluction U-value Or HTM Area (ft) Load Area (ft° Load number (Btuh/ft-F) (Btuh/W) or perimeter (ft) (Btuh) or Perimeter (it) (Btuh) Heat Cool Gross WPIS Heat Cool Gross NIFIS Heat Cool 6 Nl L--C' 13A-0ocs' ,1Actom.. .0.143 1.270 .ne 'ne 4.00i 35:56 r 2.55 ' 70.43 0 ' 0 - 0 0 0" . 0 0 .. 0 40 0 -' 40,. `. .' 0 160 0 �102 :0 V� 13A = 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 �G L-D 1A-clom 1.270 se 35.56 34.77 0 0 0 0 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 w .13A-4ccs 0.143 's '- .4.00 255 0 0 0 0 0 0 0 0 V�1 13A4= 0.143 sw 4.00 255 0 0 0 0 0 0 0 - 0 I-G 1Aclom 1270 sw 3556 42.91 0 0 0 0 0 0 0 0 13A-0dcs 1Aclorb' - 0143 :1270 nw. nvv , 400 3556 2.55 ^'. 45:24 0 0. 0 0;- 0 0. 0.'0 0 0 0.,0 •0.' 0 . :0 0 . `4A5.20M ,0.770 W . 21.56 :27.54 0 0 -. 0 0 0 - 0 0 .: 0 P 12C-0sw 0.091 - 2.55 1.28 64 64 163 82 0 0 0 0 C 16A30md 0.032 - 0.90 2-32 192 192 172 445 - -45 - 45 . 40 1D4 F 22AAO 0.989 - 27.69 0.00 192 0 0 0 45 5 138 0 6 0)AED excursion -27 -2 Enoeiope losslgain 335 501 339 204 12 a) Nfiftraton 0 0 87 24 b) Room ventilation 0 0 p 0 13 internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2000 0 Subtotal(lines 6to 13) 335 2601 426 228 Less e)dwW load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 335 0 0 2501 0 0 426 0 .0 228 15 Duct loads 31% 48% 104 1194 31% 48% 133 109 Total room load Alr required (cfm) 439 21 3695 162 559 27 336 15 Calculations approved byACCA to meet all requirements of Manual J 8th Ed . A -r# wrilghtoof - Right-SulteO Universal 2017 17.0.14 RSU08101 2017-Apr-1017:14:53 ... Wrightsoft WAC1WYNNE-7HE GRAND CARLTONL299.mp Cato = Wit Front Door faces: N Page 3 wrightsoft Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE M FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM 1 Room name BEDROOM 2 ENTRY 2 Bposed wall 32.2 ft 7.0 ft 3 Room height 8.0 ft heaticool 8.0 it heat/cool 4 5 Roam dimensions Room area 1.0 x 203.5 it 203.5 W 1.0 x 65.0 ft 55.0 it - Ty ConstWCUM U-value Or HTM Area (ft2) Load Area Load number I (BtulyftMF) (BtutJft� or perimeter (it) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 8 W. ..13A-0ocs L-G AA-61an 13AAccs .0.143, 1.270 0.143 no 'ne se 4.00 35.56 4.00 2.55 70.43 2.55 . 128 0 8o 128 0 56 513 0 225 326 0 143 0 0 48 0 0 26 0 0 106 - 0 • 0 67 17/ 11 IL---GD IA-c1om 11DO 1.270 0.390 se se 35.1% 10.92 34.77 11.31 24 0 24 0 848 0 829 0 0 22 0 22 0 236 0 244 'W V7/ I 13A4ccs 1344ocs 1Aa1om 13A-0acs. 1Ac1am' , '4AS2orrt 1200sw 16A-30md 0.143 0.143 1.270 0.143 1.270 .0.770 0.091 0.032 a sw sw nw ; mv: . nw - - .4.00 4.00 35.56 4.00' 35.56 21.56 2.55 0.90 255 255 42.91 2.55 45.24 27.54 1.28 232 34 16 0 0" 0 0 0 204 34 16 0 0 0 0 0 204 136 64 0 0 0 0 0 182 86 41 0 0' 0 0 0 472 0' 8 0 -0 0' 0 72 55 0 8 0 0 .0 0 72 65 0 32 0 0 0 0 183 49 .0 20 0 0 . 50 0 92 128 --a W `G P C F 22A-tpl 0.989 - 27.69 0.00 204 32 891 0 55 7 194 0 6 c)AED et=ursion -24 -0 Envelope loss/gain 2859 1873 600 645 12 a) Infiltration b) RoomvemJation 1 564 0 154 0 122 0 34 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal pines 6 to 13) 3422 2257 922 579 14 15 Less Warne load Less transfer Redistribution Subtotal Duct loads 31% 48% 0 0 0 3422 1064 0 0 0 2257 1078 31% 481/6 0 0 0 922 287 0 0 0 579 276 Total room load Air required (cfm) 4486 218 3335 146 1209 59 865 38 Calculations approved byACCA to meet all requirements of Manual J Bth Ed �h rrightsoft- Right -Suite@ Universal 201717.0.14 RSU08101 2017-Apr-10 17:14:53 ...Wrightsoft HVACIWYNNE-THE GRAND CARLTON-299.rup Calc = MJB Front poor faces: N Page 4 wrightsoft° Right-JO Worksheet Entire House QUICK CALCS., INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772A66-6799 Fax 772A6646796 Email: OUICKCALCS@AOLCOM Job: Date: By: 1 Room name LAUNDRY GREAT/DINING 2 E��osad wall 6.0 ft 46.0 ft 3 Roam height 8.0 If heat/coal 8.9 If heat/cool 4 Room dimensions 7.0 x 6.0 ft 1.0 x 488.0 ft 5 Room area 420 W 488.0 ft' Ty Construction U-value Or HTM Area (ft-) Load number (BtuhrftMF) (BluryfP) or perimeter (ft) (tuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross WP/S Heat Cool 6 W -. 13NAccs 0.143 no _ 4.00 255 0 0 0 0 231 194 775 • - 493 L-.G .tAclom ' . -1.270 no 35:56 70.43 -. 0 .. i 0 .. p o 38 . 0 1344 2662 13A-0acs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 1Acl m 1.270 se 35.56 34.77 0 0 0 0 0 0 0 0 11 D 11DO 0.390 as 10.92 11.31 0 0 0 0 0 0 0 0 W 113AAccs 0.143 s 4.00 '- 255 0 0 0- 0 0 - 0 0 0 W 134-0ocs 0.143 sw 4.00 255 48 48 192 122 0 0 0 0 I--G 1Aotan 1.270 sw 3556 42.91 0 0 0 0 0 0 0 0 13AAcci 0.143 m 4.00 , 2.55 0 ' - 0 b .0 .178 ' -,. 137 549 349 399 -IAclom ' 1.270 nw ... 35.56 ' ;45.24 ..0: 0'' p .. .-0' 0. .0 - 0 . ' - �'4A5-tam 0.7,70 my 21.56 ' . 27.54 0 0 0 0 41 - 0 880 --` -1124 P 12COsw 0.091 - 2.55 1.28 56 56 143 72 0 0 0 0 C 16A-30md 0.032 - 0.90 232 42 42 38 97 488 488 437 1132 F 22A9p1 0.989 - 27.69 0.00 42 6 166 0 488 46 1274 0 6 c)AED excursion 3 -56 Emvlope loss/gain 539 288 5259 5704 12 a) Infiltration 105 29 895 245 b) Room ventilatton 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 2 460 Appliances/other 0 0 Subtotal O'unes 6 to 13) 644 317 6154 6409 Less eldemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 614 317 6154 6109 15 Duct loads 31% 48% 200 151 31% 48% 1813 3060 Total room load 844 468 8067 9469 Air required (cfm) 41 21 393 416 Calculations approved byACCA to meet all requirements of Manual J 8th Ed 'ah -Fk- wrighils ft- Right -Suite® Universal 2017 17.0.14 RSUD8101 2017-Apr.1017:14:53 ...Wdghtsoft WAC1WYNNE-THE GRAND CARLTON.299.mp Cale =MJB From Door faces: N Page +1- wrightsoft Duct System Summary Jae Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 77246U799 Fax 772466-6796 Email: OUICKCALC3@AOLCOM e�roject Intormation For. WYNNE DEVELOPMENT THE CARLTON 299, FT. PIERCE, FL Bdemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 cfm 176 Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (In) H x W (In) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) . Trunk BATH h 559 27 15 0.376 4.0 OxO VIFx 18.1 115.0 st1 BEDROOM 2 h 4486 218 146 0.374 6.0 0x0 VIFx 18.6 115.0 st1 BEDROOM -A h 3501 170 149 0.297 6.0 Ox0 VIFx 33.1 135.0 st2 BEDROOM-B h 3501 170 149 6.284 6.0 OxO VIFx 41.1 135.0 st2 ENTRY h 1209. 59 38 0.510 4.0 OxO VIFx 3.0 95.0 GREAT/DINING c 4735 166 208 0.318 7.0 OxO VIFx 22.4 135.0 st2 GREAVDINING-B c 4735 196 208 0.307 7.0 OxO VIFx 28.1 135.0 st2 KITCF@N c 3695 21 162 0.376 7.0 OxO VIFx 18.3 115.0 st1 LAUNDRY h 844 41 21 0.366 6:0 Ox0 VIFx 21.6 115.0 st1 nteATri h 1162 57 54 0.366 4.0 0x0 VIFx 21.6 115.0 st1 WIC'' c 214 4 9 0.310 4.0 0x0 VIFx 26.3 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (Cfm) FR (fpm) (in) (In) Material Trunk st2 Peak AVF 737 724 0.284 689 14.0 0 x 0 VinlFlx st1 st1 Peak AVF 1101 1122 0.284 804 16.0 0 x 0 VinlFlx Q Wrl hts01•t' 2ot7-Apr-1017n4:84 ZrA 9 RlghtSuite® Universa120171T.0.14 RBU08107 ...Wrightsoft WACIWYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces; N Page 1 Name Grille Size (in) Htg (cfm) Clg (cfm) ' TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 VIFx + So Wrl htft' ��t 9 RightSuite® Universa12017 17.0.14 RSU08701 2017-Apr-1017:14:54 Page 2 ...Wrightsoft WAC\WYNNE-TIE GRAND CARLTON-299.rup Colo =MJ9 Front Door faces: N