Loading...
HomeMy WebLinkAboutEVALUATION REPORT - ROOFINGFjL LE COPY EVALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION SCANNE® `26 GA. 5V-CRIMP PANEL' By St. Lucie County FLORIDA BUILDING CODE 6T13 EDITION (2017) FLORIDA PRODUCT APPROVAL FL 14645.3-R3 ROOFING METAL ROOFING RECEIVED CONCEALED FASTENERS OR ATTACHMENTS DEC 2 0 2�J18 ARETHERESPONSIBILITY OFTHE CONTRACTOR OR RECORD ST. Lucie County, Permitting Prepared For: Metal Sales Manufacturing Corporation 545 South 31d Street; Suite 200 Louisville, I{Y 40202 Telephone: (502)855-4300�L�` Fax: (502) 855-4200 FILE COPY ST, LUCIE COUNTY REVIEWED FOR CO Prepared By: SITE OR NO INSPECTION(S) Bala Sockalingam, Ph.D., P.E. Florida Professional Engineer #62240 1216 N Lansing Ave., Suite C Tulsa; OK 74106 Telephone: (918) 492-5992 FAX: (866) 366-1543 l2,-DY2 oc_LlQ-PQi2 MADE This report consists of EvaluationInstallation Details (1 Page) cover) `,,``SOCKAL/N �PVQSFg2�,i��s . No 62240 .. Report No. C2182-3 Date: 9.9.17 THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT Po9AY BE NECESSARY IN ORDER TO COWjPLY WITH ALL APPLICABLE CODES. STATE OF c(OR1OP, ct , G . 2.0 FL 14645.3-R3 C2182-3 9.9.17 Page 3 of 3 Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory or ASTM E108AM790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: . TAS 125 Test Reports Farabaugh Engineering and Testing Inc Project No. T181-05, Reporting Date 7/21/05 (Tests #1 & 2) Project No. T240-09, Reporting Date 9/22/09 Architectural Testing, Inc. — West Palm Beach, FL (Formerly Hurricane Test Laboratory, LLC) Project No. 0103-0712-09, Reporting Date 9/l/09 EXISTING SHINGLES (OPTIONAL) NEW UNDERLAYMENT- (REQUIRED ONLY FOR NEW CONSTRUCTION) EXISTING SHINGLES (OPTIONAL) EXISTING UNDERLAYMENT (OPTIONAL) NEW UNDERIAYMENT- (REQURED ONLY FOR NIEW CONSTRUCTION) EXISTING SHINGLES (OPTIONAL) EXISTING UNDERIAYMENT (OPTIONAL) SEE DETAIL 2 / -� SEE DETAIL 1 NEW URED ONLY FO F r FASTENER AT PANEL FLAT SV-CRIMP (REQUIRED ONLY FOR 1 REQUIRED FOR PANEL (PANEL OVERLAP) NEW CONSTRUCTION) ENDS ONLY. EXISTING UNDERLAYMENI ` / MINIMUM ATTACHMENT: PRESSURE FASTENER (OPTIONAL) PRESSURE TABLE Bd x 2.5' LONG RING SHANK NAIL OR S8 x 2' LONG WOOD SCREWS SPACED ® 8' O.C. IN THE FIELD & MIN. 2X_ WOOD RAFTER/JOIST/ 4' O.C. AT PLYWOOD EDGES TRUSS AT MAX. 24" O.C. - TYPICAL PANEL INSTALLATION X—SECTION 1 WITHSELF SEALING WASHER MAXIMUM SPACING OF 36' O.C. 5V-CRIMP MIN 26 GA. DETAIL 1 19/32-THICK (MIN.) WITH SELF SEALING WASHER AT MAXIMUM SPACING OF 36' O.C. 5V-CRIMP MIN 26 GA DETAIL 2 19/32' THICK (MIN.) ALLOWABLE UPLIFT PRESSURE FASTENER SPACING (IN) PRESSURE (PSF) 36 41.6 16 74.8 8 196.75 GENERAL NOTESe 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WDH THE FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS SHALL BE MIN. 26 C4 (t = 0.0169-). EFFECTIVE COVERING WIDTH OF PANEL = 24'. 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. S. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. c n