Loading...
HomeMy WebLinkAboutLETTER FROM ARCHITECTONIC INCArchitectonic Inc December 18, 2018 Saint Lucie Count Building Department RECENED Y g P DEC 2 0 2010 Attn: Roof Permit Plan Review - 2300 Virginia Avenue Permitting Department Ft. Pierce, FL 34982 St. Lucie county Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure located at 8603 Lakeland Blvd., St. Lucie County Manufacturer: Tri-Built Roofing Products Profiles: TO —Built Modified, FL# 16027.1, System W-5 Code: ' FBC 2017; Section R 905.10 Wind Speed: 160 MPH; Ultimate Design Wind Speeds Exposure: B Mean Roof Height: 30' Maximum Pitch: Flat Roof Required Design Pressure: Zone1: -24 Zone 2: -40 Zone3:-60 Maximum Uplift Pressure: -90 Base: SBS-SA Cap: Tri-built APP-TA (torch) Modified Bitumen Roof Decking: Existing 5/8" plywood sheathing to be nailed w 8d x 2" ring shank nails @ 6" O.C. thru out Zone 1, 4" O.C. perimeter & 6" O.C. field Zone 2, and 4" O.C. thru out Zone 3. The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code, and the Manufacturer's recommendations. LU _� LL 806 Delaware Avenue Fort Pierce, Florida 34950 Tel: 772 460 7751 Fax: 772 460 4244 www.architectonicinc.com FL Reg #AA26003348 1 of 1