NOTICE OF ACCEPTANCE(NOA) www.miamidade.eovibuildine/
Monier Lifetile, LLC ST. LaEiF 6eNntr, Pprinlal119
200 Story Road �� ��
Lake Wales, FL 33853 Copy
�DN �COOFASTENERS OR
RPM HE �
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control
Section to be used in Miami Dade County and other areas where allowedby the Authority Having JurisdiceL" By
(AHJ). oqff
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product (%twele counl y
Section (In Miami Dade County) and/or the AHJ (inareas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance -purposes. df this product or material, fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of suchproduct or material.within their jurisdiction. BNC reserves the right to
revoke this acceptance, if it is determined by Miami-Dade.County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described.herein, and.has been designedto comply with the Florida Building Code
including the High Velocity' Hurricane Zone of the Florida Building Code.
THESE PLANS AND ALL PROPOSED WORK
DESCRIPTION: Tejas Espana Concrete Roof Tile REQUIRED BY FIIEELDD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
LABELING: Each unit shall bear a permanent label with the maafiWdtu'80ffadaAt& )WiJ0bp,0tjt4ib6ES,
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be consideredafter a renewal application has been filedand there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for: termination and, removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date maybe displayed, in advertising literature. If any portion of the NOA is displayed, then it. shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at.the job site at,the request of the Building Official.
This renews.NOA# 06-0711.12 and consists of pages.l through 7.
The submitted documentation was reviewed'by Alex Tigera.
MIAMI•DADE COUN LUC15 COUNTa BUILDING DIVISION � e� NOA No.: 11-0714,01-
EWED FOR COMPLIANCE (/( Expiration:Date: 09/14/16
VIEWED BY Approval Date: 09108/1.4
DATE Page 1 of 7
PLANS AND PERMIT MUST BE KEPT ON JOB
SITE OR NO INSPECTION(S) WILL BE MADE
,
TQA 155nktiA C'er� lZtD � fife is
I u; toil tc. �t 9-�w,5-r
f% al reFcc, (-,(((-)A
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub Category: High Profile Roofing Tiles
Material: Concrete
1. SCOPE
This approves a system using Tejas Espana Concrete Roof Tile, as manufactured Monier Lifetile
LLC in Katy, TX. and described in Section 2 of this Notice of Acceptance. For locations where
the pressure requirements, as determined.by applicable Building Code does not exceed the design
pressure values obtained by calculations in compliance with RAS 127 using the values listed in
section 4 herein. The attachment calculations shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Test
Product
Applicant
Dimensions
Specifications
Description
Monier Lifetile Tejas
1= 16 %'
TAS 112
High profile, interlocking, one-piece `S'
Espana Tile
w = 13"
shaped, high pressure extruded concrete
%" thick
roof file equipped with two nail holes. For
direct deck or battened nail -on, mortar or
adhesive set applications.
Trim Pieces
1= varies
TAS 112
Accessory trim, concrete roofpieces for use
w = varies
at. hips, rakes, ridges and valley
varying thickness
terminations.
2.1 MANUFACTURING LOCATION
2.1.1. Katy, TX.
Test Aeency
Test Identifier
Test Name/Renort
Date
Redland Technologies
7161-03
Static Uplift Testing
Dec. 1991
Appendix III
TAS 102 & TAS 102(A)
Redland Technologies
7161-03
Wind Tunnel Testing
Dec. 1991
Appendix.I1
TAS 108 (Nail -On)
Redland Technologies
P0402
Withdrawal Resistance Testing of
Sept. 1993
screw vs. smooth shank nails
Redland Technologies
Letter Dated Aug. 1,
Wind Tunnel Testing TAS 108
Aug. 1994
1994
(Nail -On)
Redland Technologies
P0631-01.
Wind Tunnel Testing
July 1994
TAS 108 (Mortar Set)
Nutting Engineering
13343.1
Physical Properties TAS 112
June 2006
NOA No.: 11-0714.01
MLAMMAD, COUNTY Expiration Date: 09/14/16
Approval Date: 09/08/11
Page 2 of 7
Test Agency
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
Celotex Corporation
Testing Services
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering,. Inc.
Test Ideutifl'er
22-7688-3
25-7688-10
25-7688-5
25-76884
520111-3
520191-2-1
Calculations
CaIcul'ations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
TestName/E2euort
Static Uplift Testing
TAS 101 (Adhesive Set)
TAS 10.1 (Mortar Set)
Static Uplift Testing
TAS 102 (3" Headlap, Nails,
Direct Deck, New Construction)
Static Uplift Testing
TAS 102
(4" Headlap, Nails, Clips)
Static Uplift Testing
TAS .101
Aerodynamic Multiplier
Two Patty Adhesive Set System
25-7193
25-7094
25-7496
25-7584
25-7804b-8
25-7804-4 & 5
25-7848.6
Date
June 1996
July 1996
June 1996
June 1996
Dec. 1998
March 1999
March 1999
April. 1999
March 1995
February 1996
April 1996
December 1996
NOA No.: 11-0714.01
MuuMi•onoecourm Expiration Date: 09/14/16
Approval Date: 09/08/11
Page 3 of 7
3. LimnAmNS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set --file applications, a static field uplift test shall -be performed in
accordance with TAS 106.
3.3 Applicant shall retain the services of.a Miami -Dade County. Certified, Laboratory to perform
quarterly test in accordance with TAS 412, appendix W. Such testing shall be submitted to
the Building Code Compliance Office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications
Standards listed section 4.1 herein.
3.5 30/90 bot mopped underlayment applications -maybe installed perpendicular to the roof slope
unless stated otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall- be in
compliance with applicable building code.
4. INSTALLATION
4.1 Monier Lifetile Tejas Espana Concrete Roof -Tile and its components shall.be installed in strict
compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120.
4.2 .Data For Attachment.Calculations
Table 1: Average Weight.(W) and `Dimensions (I x w )
Tile Profile
1, Weight-W (lbf)
length-1(ft)
Width-w (ft)
Monieriifetile Teas Espana
10.2
1..33
1.08
Table 2: Aerodynamic Multipliers - 2 i
fe
Tile
Profile
2. (fe)
Batten Application
2. (ft)
.Direct Deck Application
Monier Lffetile Teas si
0.262
0.284
Table 3: estoring Moments clue to Gravi - M ft-lb
Tile
Profile
3":12"
W%12"
5":12"
VA2"
7":12" or
I greater
Monier Lifetile
Tejas Espana
Battens
Direct
Deck'
'Battens
Direct
" Deck
Battens
= Direct
Deck
'Battens
' Direct
Deck
'Battens
Direct
Deck
7.77
1 8.34
1 7.65 1
8.20
7.49 1
8.03
7.30
7.83
7.10
1 7.62
NOA No.: 11-0714.01
Expiration Date: 09/14/16
Approval Date: 09/08/11
Page 4 of 7
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft4bf)
for Nail -On Systems
Tile
Fastener Type
Direct Deck
Direct Deck
Battens
Profile
(min 15132"
(min. 19132"
plywood)
plywood)
Monier Lifetile
2-10d,Ring Shank.Nails
28.6
41.2
19.4
Tejas Espana
1-10d Smooth or Screw
5.1
6.8
2.8
Shank'Nail
2-10d Smooth or Screw
6.9
9.2
7.3
Shank Nails
1 #8 Screw
20.7
20.7
18.1
2 #8 Screw
43.2
43.2
29.8
1-1 Od Smooth or Screw
23.1
23.1
19.0
Shank Nail, (Field Clip),
1-10d Smooth or Screw
29.3
29.3
24.0
Shank Nail Eave Clip)
2-10d Smooth or Screw
27.6
27.6
38.6
Shank Nails Field Clip)
2-10d Smooth or Screw
. 38.1
38.1
41.8
Shank Nails Eave,Gfl
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf)
for Twopatly Adhesive Set Systems,
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Monier Lifetile Tejas Espana
Adhesive'
29.3
1 See manufactures component approval for installation requirements.
2 Flexible Products Company TileBond Average weight per patty 10.7 grams.
PolyfoamProduct,.Inc. Average weightperpatty 8 grams.
Table 6:
Attachment Resistance Expressed as a Moment - Mf (114bf)
for Single Patty Adhesive Set Systems
Tile
-Profile
Tile Application
Minimum Attachment
Resistance
Monier Lifetile Tejas
Espana
Polyfoam Pol ProlM
66.5
Polyfoarn Pol ProT"
38.74
3 Large paddy placement of 63 rams of Pol Pro' .
4 Medium paddy placement of 24 rams of Pol Pro' .
Table. 7: Attachment Resistance Expressed as a Moment - Mr{ft-Ibf)
for Mortar Set Systems
Tile
Profile
Tile
lication
Attachment
Resistance
Monier d::itetile Tejas Espana
Mortar Set
24.5
5 Seespecific mortar manufacturer's Notice of Acceptance
NOA No.: 11-0714.01
Expiration Date: 09/14/16
Approval Date: 09/08/11'
Page 5 of 7
5. LABELING
5.1 All tiles shall hear the imprint or identifiable. marking of the manufacturer's name or logo as
detailed below, or following statement: "Miami -Dade County Product Control Approved".
LABEL FOR TEJAS ESPANA CONCRETE TILE
(LOCATED ON THE UNDERSIDE OF TILE:
6. BUH DING PERWT REQUIREMENTS:
6.1 Application for building.permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required%by Building Official or Applicable building code in
order to properly evaluate the installation of this system.
APPROVED
NOA No.:11-0714.01
Expiration Date: 09/14/16
Approval Date: 09/68/11
Page 6 of 7
. PROFILE DRAWING
When using only one
MONIERLIFETILE TEJAS ESPANA CONCRETE ROOF TILE
END OF THIS ACCEPTANCE
NGA No.:11-0714.01,