Loading...
HomeMy WebLinkAboutBUILDING SITE PLANEm SITE PLAN w/ MEMORIAL & EQUIPMENT RELOCATION SCOPE OF WORK 1. CONSTRUCT NEW CONCRETE SERNCE PAD; 1, RELOCATE (3) A/C CONDENSER UNITS AS INDICATED; 3. RELOCATE WATER PUMP k WATER FILTER SYSTEM AS INDICATED; AND ALL ARE SUBJECT TO ANY CR WORK RK CTION REQUIRED ev FIELD INSPEMAY atCTORS THAT IVECESARY IN ORDER TO COMPLYWITHSAL PLICABLEConFe PHESE DRAWINGS CONTAIN ARCHITECTURAL SYMBOLS USED FOR GRAPHIC 3URPOSES ONLY. SIZE Al LOCATION MAY VARY TO MEET MANUFACTURERS SPECIFICATIONS. DO NOT SCALE DRAWINGS. ANY QUESTIONS ABOUT DIMENSIONS, CONTACT DESIGNER. �■■�CANNED BY St. Lucie County 1 START DATE: 08.09.18 DATE LA 1 1ST_REVISION 2ND—REVISION RAY CHLADNY 4929 S. INDLAN RIVER DRIVE, FT. PIERCE, FL rr 1 /16" = 1'-0" L s1r�)-- tAj 3 DRAWING INDEX SITE SITE PLAN E1 NOTES & PLAN Site RELOCATED WEATHER PROOF, GFI 4-PLEX RECEPTACLE ON ALUM. MOUNTING POST NEW 4" TH CK CONCR f 7 TE' SERVICE FAD RELOC TE EXISTING WATER PUMP & PURIFICATION EQUIPMENT CONDENSER UNIT BASE MOUNT BRACKETS w/ 6"- 8 ' SCREWS MIN. 4" THICK CONCRETE SERVICE PAD CONDENSER ANCHOR NOTES: 1. BASE MOUNT BRACKETS TO BE STEEL, ZINC PLATED, (2) ON EACH SIDE AS SHOWN HERE WITH MIN. 1 /16" THICK x 2" x 6" x 1.5" ON BEND; 2. MIN. (1) 1/4 ;) x 2.5" S.STEEL TAPCON PER CLIP TO CONCRETE SERVICE PAD; 3. SERVICE PAD CONCRETE TO BE MIN. 3000 PSI COMPRESSION STRENGTH; 4. FASTENERS USED IN THE INSTALLATION MUST BE PROPERLY INSTALLED & COMPLETELY SCREWED IN SUCH THAT THE HEAD OF THE FASTENER ENr-AGES THE BRACKET; 5. ATTACH EACH CLIP TO THE CONDENSING UNIT USING (2) #14 X 3/4"S.S. SEI F—TAPPING SCREWS. ELECTRICAL NOTES: 2 PROVIDE RELAY SWITCHES SO IF 2 OR MORE UNITS START AT THE SAME TIME, LARGEST UNIT TO START 1ST w/ 10 SEC. DELAY RESPECTFULLY FOR EACH OF THE OTHER UNITS 17'-n" PRE-MANUF. S.STL UNI-STRUT RACK FOR 100A RATED PANEL w/ MAIN DISCON. (3) DISCON. FOR CONDENSERS O n n II ii a '110 ii II II II II II II II II ------- u u n n II ------------- ----- ii II 2 II , II II II II 11 u u n n ----------------------------- it 1 II 24 �! II II II II II II u -------- II ---- I II II II -------- u RELOCATED EXISTING 20V W.P. PUMP HARD WIRE CONNECTION NEW 1 " CP VC 11 RELOCATE EXISTING-/ CONDENSER UNITS TO THIS LOCATION w/ NEW SERVICE PADS (2) #5 BARS THE WAY & �5 CROSS 1. ALL LOAD CALC'S TO BE CHECKED BY FLORIDA LICENSED ELECTRICIAN; 2. ALL WORK TO 2017 NEC & REQUIREMENTS OF FPL; 3. ENSURE MIN. 36" CLEAR BETWEEN EQUIPMENT & DISCONNECTS, TYPICAL; 4. PROVIDE NEW G.F.I., W.P. SERVICE OUTLET & DISCONNECTS IN PROXIMITY TO RELOCATED CONDENSERS; 5. ALL EXTERIOR SWITCHES & DUPLEX RECEPTACLES TO HAVE WEATHER PROOF COVE S. OUTLETS TO BE GFI AS WELL. 6. ALL EXTERIOR SWITCHES & DUPLEX RECEPTACLES TO HAVE WEATHER PROOF COVERS. OUTLETS TO BE GFI AS WELL. 7. NEW CONTROL WIRES FOR CONDENSER UNITS SHALL BE ROUTED THROUGH THE ATS FOR LOAD SHEDDING; 8. ADD, ON —DELAY RELAYS TO CONDENSER UNITS, ONE SET FOR 20 SECONDS, ANOTHER 40 SECONDS, AND THE THIRD 60 SECONDS; 9. ALL CONDUCTORS TO BE COPPER OR ALUMINUM; ALL INSULATION TO BE THHN ABOVE GROUND & THWN UNDERGROUND; CONDUIT AS FOLLOWS: PVC BELOW GROUND; RIGID FROM U/G TO SERVICE; BOX FOR EXTERIOR LITES ON BUILDING; AC, MC OR EMT CONDUIT ELSEWHERE. LOAD CALC FOR NEW 100A RATED PANEL C FOR 3) CONDENSERS; (2) CONDENSERS: 15A RATING EACH, OR 2x3200 VA (1) CONDENSER: 25A RATING, OR 5400 VA TOTAL LOAD CALC: 11,800 VA 1 ST 1 OkVA @ 100% = 10,000 VA BALANCE @ 40% = 720 VA FACTORED TOTAL FOR NEW PANEL: 10,720 VA 102720/240 = 44.7 AMPS, 1-PH, 120/240V NO NEW ELECTRICAL LOADS ADDED TO EXISTING SERVICE WATER PIPE (3) PAIRS OF BURIED_,/ CONDENSATE LINES INSIDE PVC CONDUIT TO RELOCATED CONDENSER UNITS @ MAX 36"O.C. ENLARGED NEW EQUIPMENT PLACEMENT 3/4" = 1'-0" NEW PANEL C FOR EXISTING, RELOCATED CONDENSERS 100A RATE, 120/24CV, 1-PH, 3-W PANEL w/ (12) CIRCUITS FOR CONDENSERS & WATER SYSTEM NEW (3)#3 CU w/ #8 CU GRND EXISTING PANELS IN GARAGE EXISTING PANEL B EXISTING 300 AMP MAIN SERVICE & METER EXISTING (2) 2" PIPES EXISTING UNDERGROUND SERVICE BY F.P.L. EXISTING GROUND ROD & CU WIRE EXISTING PANEL A EXISTING W.P. PANEL w/ (2) 200A, 3-W, 120/240V DISCONNECTS & (8) CIRC. PANEL 200A DISC PANEL A 200A DISC PANEL B NEW 80A 2-POLE BREAKER TO PANEL BOX TO FEED 100A RATED PANEL FOR CONDENSERS; EXISTING RISER DIAGRAM NO CHANGE w/ EQUIPMENT RELOCATE N.T.S. NEW PANEL C FOR EXISTING, RELOCATED CONDENSERS LONG BARS 'la nr THESE DRAWINGS CONTAIN ARCHITECTURAL SYMBOLS USED FOR GRAPHIC PURPOSES ONLY. SIZE AN LOCATION MAY VARY TO MEET MANUFACTURERS SPECIFICATIONS. DO NOT SCALE DRAWINGS. ANY QUESTIONS ABOUT DIMENSIONS, CONTACT DESIGNER. START DATE: _ 08.09.18 NO.REVISION/ISSUE DATE 0 1ST —REVISION 2ND—REMSION RAY CHLADNY 4929 S. INDIAN RIVER DRIVE, FT. PIERCE, FL 0 LOT 7 ELKO SUBDIVISION (PLAT BOOK 8, PAGE 39, ST. LUCIE COUNTY, FLORIDA.) CAM .I lan l y FND4"X4" CAA NO ID N`. t�l�\ FND 1/2" 0 \ IP NO ID 0.32'N0.52'W LOT 8 ELKO SUBDIVISION (PLAT BOOK 8, PAGE 39, ST. LUCIE COUNTY, FLORIDA.) FA LOT 9 ELKO SUBDIVISION (PLAT BOOK 8, PAGE 39, ST. LUCIE COUNTY, FLORIDA.) 0 LOT 10 ELKO SUBDIVISION (PLAT BOOK 8, PAGE 39, ST. LUCIE COUNTY, FLORIDA.) REMAINDER GRAPHIC SCALE ( IN FEET ) 1 ITE PLAN w/ MEMORIAL & EQUIPMENT RELOCATION 1 /16" = 1'-0" SCOPE OF WORK 1. CONSTRUCT NEW CONCRETE SERVICE PAD; 2. RELOCATE (3) A/C CONDENSER UNITS AS INDICATED; 3. RELOCATE WATER PUMP & WATER FILTER SYSTEM AS INDICATED; GENERAL REQUIREMENTS 1. ALL WORK TO BE AS PER FLORIDA BUILDING CODE 2017 AND TO MEET OR EXCEED ALL APPLICABLE LOCAL REQUIREMENTS. 2. WORK TO BE COMPLETED AS 'HOME -OWNER -BUILDER' w/ FLORIDA LICENSED ELECTRICIAN, LICENSED WELL WATER SYSTEM SPECIALIST & LICENSED HVAC CONTRACTOR; 3. SITE TO BE KEPT CLEAN AND SAFE STATE THROUGHOUT THE COURSE OF CONSTRUCTION. 4. ALL FASTENERS & CONNECTORS TO BE INSTALLED PER MANUFACTURER'S DIRECTION TO ENSURE DESIGN STRENGTHS. 5. ALL WOOD IN CONTACT w/ CMU OR CONCRETE TO BE PRESSURE TREATED OR HAVE MIN. #15 ASPHALT FELT BETWEEN. CONCRETE SERVICE PAD NOTES 1. CONCRETE SHALL BE A MINIMUM OF a THICK OVER CLEAN, COMPACTED FILL AND 6 MIL POLYETHYLENE VAPOR BARRIER. 2. NO VEGETATION IS REQUIRED TO BE REMOVED; 3. CONCRETE SLAB SHALL HAVE (2) #5 BARS THE LONG WAY & #5 CROSS BARS 0 MAX 36'o.c.. 4. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF NOT LESS THAN 3000 PSI. 5. MINIMUM COVERAGE FOR REBAR SHALL BE 3' IN FOOTINGS AND 1-1/2' IN BOND BEAMS. HOOKS MAY BE ROTATED HORIZONTALLY IF REQUIRED TO ACHIEVE MINIMUM COVERAGES. 6. THE SLAB DESIGN ASSUMES THAT THE SOIL HAS A MINIMUM LOAD CARRYING CAPACITY OF 2500 POUNDS PER SQUARE FOOT. 7. ALL SPECIFICATIONS AND DIMENSIONS TO BE VERIFIED BY CONTRACTOR. 8. ALL EXTERIOR SLABS SHALL SLOPE MIN. 1/8' PER 12' FOR DRAINAGE. REV ISION /B(z_ ST. LUCIE COUNTY BUI G DIVI ION REVIEWED FORCOMPLI E REVIEWED BY_ W PY DATE PLANS AND PERMIT MU T BE KEPT 01 JOB SITE OR NO INSPECTION(S) WILL BE MADE TNLli PLAN/ AND ALL PROPOSED WORK ARI1*10TTO ANY CORRECTIONS R€OUTAID NY PIILD INSPECTORS THAT MAY IIk NICIUARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD. SCANNED BY St. Lucie County �aAz � I tiOa� i S7L0�I� t�yUnty, Psrrnitping a nn�ri 1772)631-5709 AA26002573 THESE DRAWINGS CONTAIN ARCHITECTURAL SYMBOLS USED FOR GRAPHIC PURPOSES ONLY. SIZE ANI LOCATION MAY VARY TO MEET MANUFACTURER'S SPECIFICATIONS. DO NOT SCALE DRAWINGS. ANY QUESTIONS ABOUT DIMENSIONS, CONTACT DESIGNER. START DATE: 08.09.18 NO.IREVISION/ISSUEJ DATE Al1ST REVISION 103.03.19 ZL 12ND_REVISION I RAY CHLADNY 4929 S. INDLAN RIVER DRIVE, FT. PIERCE, FL DRAWING INDEX SITE SITE PLAN E1 NOTES & PLAN Smite