4 SLOPE
8'-1" T.O.B.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over A5TM D
(tgpe 2) 30 lb felt undarlagment installed with min. 4' side laps and 6" and
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
c thick light textured
stucco on typical concrete
block construction
O'-O" = Finished Floor\
5/8" thick x 8"w cut
coral finished stucco bands
LEFT ELEVATION
li
5/8" thick x 8"w cut
oral finished stucco bands
Finish Columns with
5/8" thick cut coral
finished stucco bands
1 V IlL lj'�+w
ST. LUCIE COUNTY BUILD' NG DIVIS101
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #1165N1.12 REVIEWED FOR COMPLI E'
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5" REVIEWED BY LY
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D DATE
(type 2) 30 lb Felt underlagment installed with min. 4' side laps and 6" end PLANS AND PERMIT MUST lI KEPT ON )GB
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails SITE OR NO INSPECTION
spaced L' o.c. at all laps and two staggered rows 12" o.c. in field. Attach (S) WILL BE MADE
deck to trusses using attachment detail on this sheet THESE PLANS AND ALL PROPOSED WORK
ALL MANUFACTURES LABLES SHOWING ARE SUBJECT TO ANY CORRECTIONS
U FACTORS AND SHGC COMPLIANCE REQUIRED BY FIELD INSPECTORS THAT
WITH FBC ENERGY CODE MUST MAY BE NECESSARY IN ORDER TO
REMAIN ON ALL DOORS AND WINDOWS COMPLY WITH ALL APPLICABLE CODES,
UNTIL INSPECTIONS ARE APPROVED
712
O P E 1,4 CONCEALED FASTE"RERS OR ATTACHMENTS
ARE THE RESRONSIBILI 1Y GF THE
CONTRACTOR OF RECORD.
/---- 8'-1" T.O.B.
5/8" thick light textured /
stucco on typical concrete
block construction
REAR ELEVATION
SCALE: 1/4" - 1'-0" F__ I_ F__ �/ ,� I I O I X IX O T r_- s :
— Overhangs at 1'-0" unless otherwise noted on Roof Flan
— Roof pitch at -f:12 unless otherwise noted L
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12 Any changes to this plan shall be submitted to the architect
wood
ga. re crimp metal roofing attached to plywood deck using over
x 1.5° for approval In writing prior to starting construction.
wood shrews with sell' Dealing washer at 12" o.c. max spacing over ASTM D Window
I
(type s.) ne lb felt rosin underlagment installed with min. 4' side laps and 6" end Return ALL Stucco Bands Into W 1 n d ow Or Door.
laps fastened with corrosion resistant tin ceps and with 1.25" ring shank nails —
%aced L o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet \
12
SLOPE 4
LJ �5/8" thick x 8"w cut L_J
corn finished stucco bands 3
5/8" thick light textured
stucco on typical concrete
block construction
RIGHT ELEVATION
SCALE: 114" - 1'-0"
�Finish Columns with
5/8" thick cut coral
finished stucco bands
SCALE. I/4" - 1'-0"
Gulf Coast Suppig and MFG 5v Crimp Metal roofing FL #11451.12
26 ga. 5v crimp metal roofing attached to plywood deck using 49 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4 side laps and L" and
laps Fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in Field. Attach
deck to trusses using attachment detail on this sheet
� e
WiMmillm
coral finished stucco bands 8= I I
11
= F-imishad Floor Finish Columns with �/ 5/8" thick light textured
5/8" thick cut coral stucco on typical concrete
finished stucco bands block construction
FRONT ELEVATION
2" x 4" top plate 11
1/2" drywall ceiling on truss bottom cord
1/2" drywall on
2" x 4" studs at 16" o.c.
base -board 11 11 / 2" x 4" P.T. bottom plate
\ 4" concrete slab with fibermesh
OR
6"xV #10/10 WWM on 6 mil Visqueen
over
clean compacted termite treated
fill
Interior Non —Bearing Partition
nts
Braden t
Braden AIA, PA
Wt4nne
Building Corp.
Architects
- Planners
41-1
1B
S.E. Coconut Avenue
THE
STERLING
Tel :
(112) 281-8258
Fax :
(112) 281-8283
S anlsh
P
Lakes
E—mail:
bradenaia0comcast.net
St. Lucie
County Florida
=1
aaaai xaerrnnnncL")
I/8" Thick cut coral stucco over paper
backed wire lath nailed to substrata through
one layer of 15 lb felt using 8d nails_ Substrate
to be 19/32" CDX PI wood nailed at 6" o.c,
in field and edges with IOd ring shank galvanized
nails into truss webbing.
12
SLOPE 4
SCALE: 1/4" = 1'-0"
2"
thick X 8"w cut
coral finished stucco bands
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
PERMITTING INFORMATION (FORM 100)
Florida Building Code Residential: 6th Edition and ASCE 1-10 for Wind Loading
Building Design is: Enclosed Risk Category: II Wind Velocity: I45 mph ultimate
Mean Roof Height: 11'-O" Roof Pitch: 4:12
Internal Pressure oe icient. ± 0.18
Subjectabilitr to damage from: Weathering: Negligible Termites: Veru Heavu
Width of Roof End Zone: 3'-4" Wind Speed: I45 mph ultimate
Wind Exposure Classification: C 1.21 x O.L = 0.126
Adjustment factor for Exposure Height: ASD design
Load Combination: ASCE 1-10 Section 2.4 DL+LL; DL+O.LWL. O.LDL+O.LIDL
Components t Cladding Wind Pressure (NET) Roof Zone: L +20.L/-32.6 psf
Roof Zone: 2. +20.6/-51.0 psf
Roof Zone: 3. +20.6/-84.0 psf
Components t Cladding Wall End Zone Width: T-4"
Components t Cladding Wind Pressure (NET) Wall Zone: 4. +35.8/-38.1 psf
Well Zone: 5. +35.8/-41.8 psf
Components t Cladding Wind Pressure (NET) on Garage Door: +32.0/-40.3Pat
Shear Walls Considered for Structure? Yes
Continuous Load Path Provided7yea
Are Components an Cladding Datalilas Provided? Yes
Minimum Sol Bearing Pressure:2.500 psi. Presumptive: X Bg Test: psi
ROOF i-IVE LOAD: 3-1 pat ROOF DEAD LOAD: 10 psf
FLOOR LIVE LOAD: _A5_ oaf FLOOR DEAD LOAD: 10 Pat
JOB ADDRESS: � N',�� Coe,-��
MODEL:
REAR
PORCH
RIGHT
Date Drawn
5-24-18
Drawn by:
C.C.U.
Checked by;
D.R.B.
Revisions
ED = Roof Zone I
Walls Zone 4
® = Roof Zone 2
Walls Zone 5
END ZONE
Corner Zones
Roof Zone 3
Sheet I Comm #
OF 5
FLOOR CLAN
CRASH POST DETAIL
TYPICAL NOTES: SCALE 1/4" = I'-O" N.T.S.
I. Contractor to verify ALL notes and dimensions prior to steel
high by 4" diameter
steel crash post. Floor
proceeding with work. Flange with 4 - 3/8"
2. Contractor to STRICTLY enforce ALL OSHA Requirements. ex ansion bolts Into
3. ALL Lumber to be used as Beam, Rafters, etc... to have slag (3/8"t 50 ksr steel plate)
a minimum 1,400 P.S.I. fiber stress. me L"
4. No dissimilar metals to touch. 2�." 2r,°
5. ALL Concrete used for slabs shall be min. 2,500 PSI concrete.
ALL Concrete used for vertical filled cells, cont. tie beams etc.. to o
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix 03/8" 2%.
L. Drywall at ceilings shall be leveled and attached to bottom chord
of trusses with screws per FBC R102.3.5. 2 °
O O
1.
ALL wood in contact with concrete shall be pressure treated.
8.
ALL wall dimensions are nominal and not finished wall or stud dimensions.
9.
ALL plumbing fixtures to be low flow.
10.
Contractor to Provide Drain at water heater in accordance
with the current edition of the Florida Plumbing Code.
11.
Contractor to Provide a 2'-8" wide door at one bathroom for
handicap accessibility requirements.
12.
Lowest finished floor to be set by Governing Building Department
`
surveyor to set in field.
13.
Separation between residence and garage shall be per FBC R302.6
1-4.
Door between garage and residence shall be 1-3/4"t 20 min, rated door
w•H• = Water Heater
15.
Wall and Ceding shall have a flame -spread classification of not greater than 200 Der
FBC R302.9.1
16.
Wall and ceiling finishes shall have a smoke -developed index of not greater than -450
per FBC R302.9.2
11.
Ail exposed attic insulation materials installed on attic floors shall have a critical radiant Masonry Beam
flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation
I" x L" P.T. Buck nailed to
block with case hardened nails
materials exposed on the underside of the roof deck or on the attic walls shall comply
prior to door attachment
with F.B.C. R316 - see permit info box of code edition
18.
G psum board material shall conform to ASTM C36, C19, Cif-f5, C514, C630, C931
C40, C1002, CIO-4-1,C11-17, C1118, C1278, C1395, or C1396 and shall be installed
accordingto the following:(FBC R102.3.5)
":.
Drywall
Thickness
Location
Orientation
Framing
Member
Max. spacing
fast
fasteners
Nail sizinoptions for
g
Spacing
of
Installation of drywall Into
Nails
Screws
Maximum
wood framing members
2 x min. thickness
Ceiling
Perpendicular
24"
1"
12"
13ga 1 3/8" long with 19/64' head
0.098" diameter x 1 1/4" long
/2„
annular -ringed or 5d cooler nail
OR
0.080" di . xx 1 5/8" tong with
Walls
Either
IL"
g
IL "
Direction
15/64' head
OR
Ggpsum board nail 0.086" dia.
x 1 5/8" with 9/32" head.
Ceiling
Perpendicular
24"
12"
13ga 1 5/8" long with 19/44" head
0.098" diameter x 1 3/8" long
„
annular -ringed or Ld cooler nail
O
0.092" dia. x 1 -/8" long with
Walls
Either
14"
8"
16"
Direction
1/4" head
OR
Gypsum board nail 0.0915" dia.
x 1 -1/8" with 19/64" head.
Install SGD thru buck into 0 block with 3/I4" tap -con with �-
1 1/2" penetration at 0 o_c. max.
from each corner and 20." o.c. max
thereafter at head per product approval
F1
Use 3/I6" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20" o.c. max
thereafter at sill per product apprc
19. ALL ceramic tile surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, A136.1 and A13-1.1
20. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM
C1288, C1325, OR CII-18 and installed I.A.W. manufacturers recommendations shall
be used as backer for the wall tile in tub areas and wall panels in shower areas.
21. Insulation including facings such as retarders or vapor permeable members installed
within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics
Shall have a flame spread index not to exceed 25 with an accompanying smoke
developed index not to exceed -450 when tested in accordance with ,ASTM E 84.
Insulation shall comply with F.B.C. R316.
Gulf Coast supply and MFG 5v Crimp Metal roofing FL #11651.12
24 go. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25' ring shank nails
spaced L o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet \
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) 10d x 1 1/2" nails
1 24' o.c.) supportmg Max.
ISl0lbs. uplift
12
47
PRE-ENGINEERED TRUSSES
at 24"o.c. TYPICAL
(shop drawings by manufacturer)
Aluminum Drip
' \R-30 blown fiberglass
Edge i Fascla_�
in bottom chord or trusses
TIM
I/2" drywall with smooth finish
2" x 6" Sub -Fascia
Two rows of beam block filled with concrete
and (1) #5 bar cont. in each row. Substitute
Kaycan full o vent vin�l soffit installed
wing 1/8" dia shank x 5' tong
precast lintel filled with concrete and (U #5
bar Cont. for bottom row over openings
gale.
rooting nails with 3/8' dia. head par
product approval - see chart sheet fill
1/2" drywall over I" x furringg
R4.1
strips at 14" o.c. with ff-fod
insulation on typical
On Block walls
5/8" thick light textured
All drywall to
be installed per FBC R102.3.1
stucco on typical concrete
T
and shall meet all peirtair ASTM codes.
block construction
m
Mortar to be Type M onlg proportioned per FBC R601.1
and Mortar Jonts shall comply with FBC R601.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
#5 bar vert. w/
30" overlap
Fill cell with concrete and
at each filled cell
(U #5 bar vert. ftypical).
Max. spacing shall not exceed
Wood
48" unless otherwise noted
Base
see foundation plan notes for
spacing at openings
4" concrete slab with fibermesh OR
L"x6" #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
Grade
,IIIH1
_
III
II
II-
-IIIIII11-1
Ili
ii
14
14" x 14" Concrete footing
#5
with (2) #5 bars coat. and
TYPICAL
S C T
I O
N
transverse bars at 48" o.c.
AREA
CALCULATIONS
Living A/C
= I9-f1,4 sq. ft.
Front Porch
= 153 sq. ft.
Rear Porch
= 116 sq. ft.
Garage
= 321 sq. ft.
Total Under Roof= 2,124 sq, ft.
Total Cubic Ft = 11,192
2" VTR
JAL
1
1
I
21' VTR
JIL
Me ter I
Beth
ILaw.
I
I
2'
Lay.
I
11' 1 2' VTR
W.C. I IL
I I
Shur.
3' % I I
Kit. amk I
Kitchen a'
I
I
I
Lev.
3'
W.C.
Bath #2 s
3'
C.O. To septic
PLUMBING
RISER
I" x V P.T. Buck nailed to O
block with case hardened nails i
Head prior to door attachment O
L,
fixed door `
sliding door
Masonry Wall y.;';
Bottom Track `-Typical Flooring
Sill Install SGD thru buck into
block with 3/I6" tap -con with
S l l d i n g D Oar D e t a l l I I/2' penetration at 6" ." max.
from each corner and 20." o.c. max
thereafter at Jambs per product approval Jamb
At Masonry Wall NTS
Window
Schedule
Mark
Size
Rough Open.
Window Description
PRESSURE ZONE
I.
4'-5Ya"x V-3 /a"
54/a"x 63/4'
15" x 63 /f"
Single Hung
ZONE 4
2.
V-2Ya"x 5'-3 /a"
Single Hung
ZONE 4
3.
2'-2" x V-2 I/T
2l%2"x 38%"
Single Hung
ZONE 4
4.
4'-5Ya"x 4'-2 /e"
1 54%a"x 54Ye"
I Single Hung
I
ZONE 4
ALL
Windows to be aluminum
windows w/ tint
and mullions per
elevations.
ALL
windows to withstand
pressures in permit info box on
sheet I
ALL
windows in bathrooms to
be tempered
All
rough opening
dimensions
to be verified by contractor
with
manufacturers specs prior to construction
Door Schedule
Mark
Size
Rough O ening
Door Description
PRESSURE ZONE
A
9'-0" X 1'-O"
108" x 84"
Overhead Garage Door
ZONE 4
B
3'-0" X 6'-8"
41 %,"x 83%"
Fiberglass Panel - Inswing
ZONE 4
C
6'-O" X 6'-8"
14" x 81 %2" d;c;,;°"
Sliding Glass Door
ZONE 4
D
2'-O" X 6'-8"
Solid Core - Wood
- 6-Panel -Bi-Fold
Finished 24' x 81
E
2'-V X V-8"
Solid Core - Wood
- 6-Panel
F
51-0" X 6'-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
G
2'-8" x C-8" x i %"
Solid Core Wood, Steel, or Masonite Door
H
2'-8" X 6'-8"
Solid Core - Wood
- 6-Panel
J
2'-6" X 6'-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
2'-e" X 6'-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
L
I'-6" X 6'-8"
BI-FOLD
ALL Exterior doors to withstand pressures stated in permit info
box on sheet 41
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET #1
All rough opening dimensions to be verified by contractor
with manufacturers specs prior to construction
N
0 1
in
N
w
A
3" L'-O I'
NOT
ON THIS PERMIT
Opt. mul`IIrcX. vAt
ON THIS PERMIT
12' x 12" Concrete column
block filled with concrete and
(2) #1 bars vert. tied Into
lintels above
Covered Porch
8'-0" to 19'-8" A.F.F.
Vault d Ceding
G EAT
OOM
I
I
I
14'-0"
I
MASTER
BEDROOM
V-0" A.F.F. Ad-\
Flat Ceding
Rod 'f Shelf
I U)I
I 8'-0" to 9'-8" fj.F.F. OL 2" x 6" knee -wall aD
Vaulted Ceilirtq below counter top 1
DiNING IrCLOSET
ROOM F all LRod Shelf
be / r _
DW-7
\
Vanity to be
/
34 Y2' high
9Y�I'Hlgh 111) "
K�ITCHENa
m SECOND
BEDROOM
ty to be
4"high
J1 r
1714
�jver ang B'-O" A.F.F.
Flat Ceding
6'-O" 1
„ pper cabinets to
extend over cf. iti
I
MINIM
1=
U
-IIL r
i
p
EGRESS
nui I W I iu1��6;ju I iui r
T
3'all
12" x 12' concrete column block filled C V E R D
with concrete and (2) #1 bars vert. tiedFORCH
/ into lintels above
12'-6" T-
Install windows thru buck into
block with 3/16" tap -con with
1 1/2" penetration at V o.c. max.
from each corner and 20." o.c. max
thereafter at amba and 20" o.c. max.
Exterior face at head and sill per product approval
of wall -\ J \ Buck to be I" x 4' PT
GARAGE
"
8'-4" A.F.F.OILC
Flat Ceding
f
r-----------------i
Block wall in
garage to be
struck block
I I
I I
� I
5'-2" 2,-8, 2 _8„ 3,_5„ 91-01,
5'-4" 15'-10"
36' -O"
x4" P.T. Buck nailed to INSTALL VULKEM BLOCK SEALANT
I"
lock with case hardened nails ON ALL JAMB, HEADER, AND
Detail at w 1 n d ow S prior to window attachment SILL BLOCK PRIOR TO BUCK
INSTALLATION
NTS
Exterior face
of wall -\
H.B.
s
lu
f-
I
filler n
m
T
N
rler
wall
A/C o
meter
Attach buck to block wall with
1/4" dia. Elco conc screws with min.
1 1/4" penetration at 12" o.c. max
and 4" max from each corner thru
2" x 6" PT Buck
Detall at Door
O
Ln
#8 Wood screws thru jamb into buck
at each hinge and 15" o.c. max and
prior to door attachment
NTS
Scale : 1/2" = I'-O"
STRUCTURAL
NOTES:
I.
ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL
8.
SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM
FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN.
2.
ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS
9.
DESIGN LOADS ARE AS FOLLOWS:
ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI
ROOF (DL+LL) = 41 PSF
WIND VELOCITY = PER PERMIT INFO BOX ON SHEET #1
BE 3000 PSI OR 4,000 PSI GROUT MIX AT 28 DAYS
EXPOSURE ="C"
S.
POISON SOIL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS. NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
10.
ALL REINFORCING STEEL SHALL BE GRADE 40, MEETING ASTM A-I6, t
4
GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ 6X6 10/10
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 301 STEEL.
WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL
11.
ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
MIX MAY BE SUBSTITUTED FOR WELDED WiRE MESH.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
5.
LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL IS BROUGHT IN. FILL MATERIAL SHALL CONSIST OF
CLEAN GRANULAR SAND CONTAINING LESS THAN 10% MATERIAL
12.
MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
PASSING THE US STANDARD NO. 200 MESH SIEVE. PLACE
FOOTING: 3"
STRUCTURAL FILL IN LOOSE LAYERS OF 12" IN THICKNESS AND
BEAMS: 1-1/2"
COMPACT EACH LIFT TO AT LEAST 95% OF ITS MODIFIED DRY
PROCTOR VALUE.
13.
LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS.
6
GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
14.
USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1400 PSI
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
ATTENTION OF THE ARCHITECT.
15.
ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF IOOo
PSI OF NO.2 SOUTHERN PINE, UNLESS NOTED OTHERWISE.
l
GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
16.
ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
FOUNDATION FLAN
I. Any changes to plans must be submitted to the architect
for approval before proceeding with construction.
2. Contractor shall be responsible for verification of all
notation and dimensions before starting construction.
3. Soil conditions assumed to be 2500 psf. Should any other conditions be
encountered, the architect shall be notified in Writing for revision
4. Verify all recess thickness at showers, tile, etc....
S. Contractor to provide filled cell with concrete and 1 1*5 bar vert. at -48"
o.c. max. Provide (1) filled cell on each side of openings upp to 5'-11" wide.
Provide (2) filled cells on each side of openings from 6'-O" to 9'-I1"
and Provide (3) filled cells on each side of openings from 10'-0" and up
Contractor to see plans for any other condition used. Foundation walls
shall have filled cells at 2-4)1o.c. unless otherwise noted (see section)
6. Contractor to provide for Form Board Survey - Form Board Survey
to be provided to Truss Company prior to truss construction
1. Contractor to provide for soil test prior to construction and provide
a copy of soil test to architect for review prior to construction
8. ALL Reinforcing steel shall be grade 60, meeting ASTM A-16 and
A-35 specifications. ALL Anchors to be A-301 steel.
9. Provide a minimum of 3" concrete protection at footings and
1-1/2" concrete protection at beams for ALL reinforcing bars.
#5 bar vert. w/ Thicken edge to 8"x8"
30" overlap SEE TYPICAL with concrete and
at each filled cell _,SECTIONS one US bar continuous
4" concrete slab with fibermesh OR
VxV #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
ao11111111111302
14"
TYPICAL FOOTIN
1111—
"w x 14"d concrete monolithic
,otmg with (2) #5 bars Cont.
DETAIL
4" concrete slab with fibermesh OR
Cx6" 410/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
U5 bar cont.
Step per
foundation plan
101, BPI (2) #5 bars cont. bottom steel
12"
DETAIL AT GARAGE STEPDOWN
12" x 12" concrete column
block filled with concrete
and (2) #1 bars vart. tied
into lintels above Verify house slab
height in field
Top of looter
IL" below finished floor_ '
'ill=1 I I I
30"x30"xl6" concrete
column footing with (4)
#5 bars each wag
30"
OLUMN FOOTING DETAIL
SCALE 1/2" = 1'-0"
io
[A=Z-303
SCALE: 1/4" = 1'-0"
Termite Protection for New
Construction.
Soil treatment used for subterranean termite prevention
inside the foundation perimeter shall be done after all
excavation, backfilling and compaction is complete.
If soil area is disturbed after initial chemical soil treatment
area shall be re -treated with a chemical soil treatment
including spaces boxed or framed.
Treatment must be in accordance with the rules and laws
established bg the Florida Department of Agriculture and
consumer services.
Protective sleeves around metallic piping penetrating
concrete slab on grade floors shall not be of cellulose
containing materials and shall receive application of
termicide in annular space between sleeve and pipe.
4" concrete slab with fibermesh OR
4"xV #10/10 WWM on 10 and Visqueen over
clean compacted termite treated fill
PORCH SLAB EDGE DETAIL
95 bar vert. w/
30" overlap
at each filled cell
Adjust curb height
based on gar. floor
slope.
#5 bar in curb \
ao �
ITANN e 4
1/2" = ]'-0"
TYPICAL
TIONS
4" concrete slab with fibermesh OR
VxV #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
O'-O" ® P.F.
I 14"w x 14"d concrete monolithic
footing with (2) #5 bars Cont.
14"
CURB DETAIL
SCALE 1/2" = 1'-0
"
2" x 4" PT wood secured with \
3/8"ilia. x 4" anchor bolt at 18" o.c.
overhead door track secured to wood
jamb per manufacturer's product approval
Garage Door Jamb Detail
GARAGE DOOR TO WITHSTAND PRESSURES STATED NTS
IN PERMIT INFO BOX ON SHEET #I. SEE PRODUCT
APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL.
Filled Cell Masonry Column With One
#5 From Footing To Tie Beam
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Sinole Filled Cell Column
Cell Column
NTS
Filled Cell Masonry Column With One
#5 From Footing To Beam Each.
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
ouble Filled Cell Column
NTS
au
w
2" 10'-O" 12"1 10'-01, — — 14'-0"
I � I
I � I
IOpt. PATIO/SR
41
---- w O°
1
�
�
a>
z
o
i
I
- 0 1 I
- Rear Patio/Slab 1
r
I pj to be poured separate 1
18 fZ from the house slab. 12'-a I
"
Q fl
4
O
I J Thicken footingg to
N in 24"w x 14"d x 24"L FI
L
1 under filled cells
- under grader bearing. I
I�
e o 0 0 0 0 0 o N
e
°
_ _ _ _ _ _ _ _ _ I
— — — — — — — — — — — — --i
Rear Patio/Slab to
CD
FI beflush with bottom of sliding door recess. l 1
0
� j rn
°
I Slope 1/2"
$o u
F
-a
l
yr
�
_ W
CL
II
I
ICD
I
-'
I
of
FI
of
�I�
I
Vanitg to be
—b1
1 4" concrete slab With fibermesh OR 34 ' �fiigh
H-B-
1 Cx6" 410/10 WWM on 6 mil Visqueen over
I clean compacted termite treated fill 7
0
I FI 1
I
eI
I�
f_
_
Q
_a
I FI
Ln
I
1
•
1 r - - 4"0 Steel Ballard I
luJ�1 I ®Pilled w/ Concrete
I 1 >> 1 11 >
� �
Q2
#i
`r
a
uu
I �,a J 1 I v�� I
ya
I FI I I v,wE 1
ad)
I FI I 1 -L- E`` 1
I a r-- L
C
°
Ell
0
_ _ _ _
e OO i i i o O ° _ (aO V
I W-
;r
e
u
A- - I°
W Q x
I
an
I
6 to 12'-6" T-2"
I Q
F 4 e — — _ — Recess for F5
4 —
°
-
°— — — — — — — — — I ---- �° ° ° Garage L'Soor ° ° ,�
00
�3
12"
x 12" concrete column block filled
wi
h
concrete and (2) 91 bars vert. tied
into lintels above
3'-5"
9'-0.1
3'-4"
5'-41,
3C-O"
FOOTING
SCHEDULE
Mark
Size
Description
FI
14"w
x 14"D
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS
F
12"W
X 12"D
MONOLITHIC FOOTING
WITH (2) #5 BARS CONTINUOUS
Q
30"
x 30" x 16"D
COLUMN FOOTING WITH (4) #5 BARS EACH WAY
F
8"W
x 8"D
THICKEN SLAB EDGE
WITH 1 #5 BAR CONTINUOUS
F5
14"W
With
x 14"D
Curb at Garage
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS - CURB a O'-ON
Provide #5 bars with min. 48 bar
diameters overlap into beam. Tie
Pilled cell steel Into continuous
beam block steel
Provide #5 bar act in pre -cast
lintel into beam where length of
the opening calls for it.
ROOF SHEETING
ATTACHMENT DETAIL
I. Minimum Nail Size = 8d ring shank (min. 2.5" long)
2. Minimum Screw Size = US x 2"
3. Minimum Sheathing Thickness 19/32" CDX Plyywood
4. Use nails or screws band on Presage for root stated
in permit info box on t ese pPans fpor zone 3
Ke
Area
Edge
Field
Fastener
as r
Zone 1
6"
6"
8d ring shank
45 psf
Zone 2
it
6"
8d ring shank
16 psf
Zone 3
4"
4H
8d ring shank
84 psf
** Zone 3a
6"
6"
#8 wood screw
112.6 psf
** Use nails or sprews based on res ure for r of stated
in permit info box on these pl�no or zone
Provide Cast -Crete
8U8-OB/OT precast
lintel set in mortar-.
Min. 8' Bearing
Provide PT Buck
'
i, • ',i
attached per iamb
etails into filled cal
i'. J
4" Pre -east
Sill
F .1
-.y
,
]
---Poured Filled Call
Provide #5 bare with min. 48 bar
—Idiametera overlap in filled cell. Tie
iUed call steel into continuous
looter steel.
Concrete rooting
— —' ►, >;:—''= (see rooter schedule
exact sizes)
DETAIL AT WINDOW OPENING IN
CBS WALL Scale: 1/2" = I'-0"
SINGLE PLY REAR GIRDER TRUSS
Nail 2" x 4" blocking to vert. leg of
truss with IOd x 1.5 nails at 4" o.c.
Verify with Plan
r Install Simpson MGT into wall usin
Concrete r1collumn
x 12" c+___�---5/8" dia. threaded rod set min. 11'
Lintel �� Block into wet beam and (22) IOd nails into truss
Rebar
Rebar 48 Bar Dia.
Min, Overlap TRUSS BLOCKING DETAIL
Column to Lintel Attachment AT GIRDER STRAPPING
AT CENTER BEARING POINT
NITS
1/8" thick light textured stucco installed per
ASTM C 926 over ASTM D type 2 paper backed
wire lath nailed to substrate through one layer of
ASTM D T e 2 felt paper using 8d nails. Substrate
to be 19/3 COX Plywood nailed at V o.c. in field
and edges with 10d ring shank nails into studs.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
26 ga. 5v crimp metal roofing attached to plywood deck using 99 x 1.5"
wood screws with self sealing washer at 12' o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4 side laps and V end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
?aced 6 o.c. at all laps and two staggered rows 12 o.c. in field. Attach
dpsick to trusses using attachment detail on this sheet
LINTEL SCHEDULE
Mark
Window
or Do
Unit
Width
Lintel
Size
Cast -Crete
Specification
Rows of
"H' Block
Above
' "
Bottom
Steel
size
Top
all
Size
Max.
Gravity
Load
(PLF)
Max.
UphPt
Load
(PLR)
Max
Lateral
Load
(PLF)
L22
T-2'
T-6'
8198-05/IT
1
#5
3069
1569
1024
L31
2'-LR
4'-0"
8F8-OBAT
1
#5
2561
1363
143
L45
4'-5'
W-10"
8108-05/IT
1
#5
1 1105
909
339
L50
5'-0"
A'-L"
8118-OBAT
I
#5
1 1238
836
121
L60
6'-8"
T-V
BF8-OBAT
1
#6
1011
121
534
L80
V-O"
9'-4'
BF8-8/2T
1
#5
2
#5
152
591
1 512
L90
T-O'
10'-6"
BPS-IS/2T
1
#5
2
#6
643
530
401
L90B
9'-O'
10'-6"
8FI6-IB/2T
ONE
1
#5
2
#5
1533
1183
401
LI00
ID'-O'
ll'-4'
BPS-IB/2T
1
85
2
85
582
444
452
LIOOB
10'-0"
1 11'-4'
8FI6-I13/2T
ONE
1
85
2
#5
136L
1028
452
LI20
12'-0'
lV-4'
81-8-I5/2T
1
#5
2
86
1 411
428
324
L120B
12'-0-
13'-4"
8FIL-IB/2T
ONE
1
#5
2
#5
1015
1-10
324
1.140
14'-0'
15'-4"
819I6-15/2T
ONE
1
#6
2
#6
1250
609
259
LI60
I6'-0"
IT-4"
BF8-IS/2T
I
#5
2
#5
300
192
144
LILOB
iv -Om
IZ'-4"
SFI6-I13/2T
I ONE
1
#5
2
#5
950
600
194
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-0" LONG ARE TO BE PRESTRESSED.
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) 10d x 1 1/2' nails —
( 24" o.c.) supporting Max.
1810lbs. uplift
Aluminum "" _
Edge t Fascia
12"
2" x 6"
Kagean full o vent vmyyl sarht installed
vain 1/8' dia shank x 15" long gaiv.
raofping nails with 3/8" die. head per
product approval - sae chart shoat #1
O
12' x 12' concrete column
block Idled with concrete
and (2) #1 bars vert. tie
into lintels above
thicken edge to 8"x8"
with concrete and
one #5 bar continuous
BEYOND
Top of Tooter
I6" below finished floor
12
4
Aluminum Drip
Edge t Fascia
Flash and Counter v
flash
Nail ledger to
gable end truss
with (2) IOd " �ils
at each web
314" penetration
members
5/8" thick light textured
stucco on typical concrete
block construction
Varies - see plan
#5 bar vert. w/
30" overlap
at each filled cell
Rear Patio/Slab to
be flush with bottom of
sliding door recess.
Step per foundation plan
a Slope per foundation plan
IIII—IIII _...,�! .'..,.: •:.,...� ki
IIII,�IIii iii1-IIII-IIII=1'
IIIMk011�11 IIII
=11111=ii 1
lcal SeC tlOn
Brace Gable end
with 2" x 4" SYP #2
aft back nailed to bottom
Of top chords using (2) IOd
nails at each truss
Ul
u
LU
ly ri
L,
W-o�
O
~-
F-
LU
I
Lo
Brace Gable and
with 2" x 4" SYP #2 min.
aft back nailed to bottom
of top chords using (2) IOd
nails at each truss ---1
21
PRE-ENGINEERED WOOD TRUSSES
of 24"o.c. TYPICAL
( shop drawings by manufacturer )
&2mimO
\R-30 blown fiberglass
in bottom chord of trusses F-
-1/2" drywall with smooth finish UJ
Two rows of beam block filled with concrete =
-and (U #5 bar cant. in each row. Substitute
precast lintel filled with concrete and (1) #5
bor cunt. for bottom row over openings
1/2" drgwall over I" x furring
strips ai I6" o.I.. with R4.1 f _Foil
-insulation on typical 8" Block walls
Simpson I-IETA 20
hurricane anchor at each truss
( 24" o.c.) supporting Max.
1810 lbs. uplift ETA 20
Strap truss to wall
using Simpson MGT with
5/8'
dia.
threaded
rod with min 12" embedment
into
beam
either wet
set or in epoxy with
t22)
IOd
nails into
truss. Add blocking to
truss
leg
per detail
on this sheet
�i■ice■i■NEREWA
s�!e�e����
Fj'
/,
11
UNW311 MENEM--
oil
IN
I W.
2
. Uwe
h corrosion resistant tin caps and with 1,25" ri sh In
all [a
atta and two sta2gered rows 12" o.c. in
OWE
bill
Va,
Attic Access
with light SLOPE ]Iq
I
Mama
ANN ME
I
all
N
All drywall to be installed per FBC R102.3.1
i and shall meet all pertaining ASTM codes.
m Mortar be Typa "M" FBC
-
ETA 20
R601.1
to only proportioned per
and Mortar points shall camplg with FBC R601.2.1.
Provide Dur-O-Rock at all wet areas (ax. showers,
tubs etc...)
FIII call with concrete and
(not
ROOF
M. spacing shall not exceed
Max.bar g shall ex
48" unless otherwise noted
see foundation plan notes for
— OVERHANGS AT 1'-0" UNLESS OTHERWISE NOTED ON THIS SHEET
spacing at openings
— ROOF PITCH AT 4:12 UNLESS OTHERWISE NOTED ON THIS SHEET
4" concrete slab with fibermeah OR
6"x6" #10/10 WWII on L mil Visqueen over
— TRUSS SHOP DRAWINGS TO BE PROVIDED BY MANUFACTURER
clean compacted termite treated fill
t
— ANY CHANGES TO THIS PLAN SHALL BE SUBMITTED TO THE
ARCHITECT FOR APPROVAL IN WRITING PRIOR TO STARTING CONSTRUCTION.
—III,;,,II
ALL TRUSS TO TRUSS CONNECTIONS BY
=jII1-
TRUSS MANUFACTURER
II-
F1
- ARCHITECT TO REVIEW TRUSS SHOP DRAWINGS PRIOR
TO CONSTRUCTION FOR LAYOUT AND UPLIFT VERIFICATION
at Front Porch
— CONTRACTOR TO PROVIDE FOR FORM BOARD SURVEY AND TO PROVIDE
srAl.. • I/2" = 1'—n"
FORM BOARD SURVEY TO TRUSS COMPANY PRIOR TO TRUSS CONSTRUCTION
PANEL
"A„
Pala*
DR
Load
Wire
Description
circ#
arc#
Description
Wire
Load
SR
Pala
2
40
1.0 kw
#8
A/C camp
I
2
AHU
#10
3.5 kw
90
2
3
4
2
30
4.5 kw
#10
40 gal. water HTR
5
6
Range
#6
12.0 kw
50
2
I
8
1
20
1.8 kw
1 #12
Pump
'I
1 10
Dr er
#10
5.0 ks
30
2
11
12
1
20
1.5 kw
212
13
14
Dishwasher
912
1.2 kw
20
1
1
20
1.6 kw
#12
Microwave
i5
I6
Refrigerator
#I2
1.2 kw
20
1
1
20
1.6 kw
#12
Kitchen S.A.C.
11
Ie
Racepts
#12
20
1
1
20
1.5 kw
#12
Kitchen S.A.C.
19
20
Racepts
#12
-
20
1
1
20
1.2 kw
212
Clothes Washer
21
22
Racepts
#12
-
20
1
1
20
O.al kw
#12
Garage Door Opener
23
24
Recepts
#12
20
1
1
20
1.4 kw
#12
25
26
Racepts
#12
-
20
1
1
20
1.92 kw
#12
21
26
Racepts
#12
-
20
1
1
20
#12
General Lighting
29
30
Racepts
#12
-
20
1
-
1
20
#12
General Lighting
31
32
Racepts
#12
-
20
1
-
1
20
#12
General Lighting
33
34
Exterior GFCI
#12
-
20
1
-
I
120
#12
General Lighting
1 35
361
Bathroom GFI
#12
20
1
I
20
#12
Smoke Detectors
31
38
General Lighting
#12
-
20
1
1
20
#12
Bathroom GFI
39
40
General Lighting
#12
20
1
s are
41
42
s are
PANEL "A" LOAD CALCULATION SHEET
Load Description
of .
Watts
Total(Watts)
General Lighting .(3 wotts s9 ft:).........................
Small. Appliance, Circuit(s) . . . . . . . . .. ......... .............
.Range
.Refrigerator.. , .... . ....... .
Microwave ......
................................
Dish Washer ...................................................
Clothes„Washer...............................................
Clothes..Dryer,,,,, ,.
Heater
.W..ater....
..........................................................
Water. Pump ...................................................
Garage, Door .Opener .. ..............
1135
3
5,205
2
1,500
3,000
1
12 000
12,000
I
1.200
1,200
1
1500
1500
1
1,200
1,200
1
1200
1200
1
5.000
5,000
1
4500
4 500
1
1,800
1.800
810
1
810
Total Watts
31,415
First 10000 Watts e100%
1
10,000
Io.o00
Remainder 21,415 e40%
1
0
10,966
Electric Heat or A/C 10,000 965%
1
10,000
10,000
Calculated Load
Watts
30,966
Voltage
240
Calculated Wattage Divided by Voltage = Total Amps 129.03
Panel Size Required = 150 Amps
Electrical S mbol Legend
$
Single Pole Switch
®
Recessed Can Light
Ss
Double Pole Switch
®
Eyeball Recessed
PB
Push Button Switch
Exhaust Fan
8
Duplex Outlet
-{�
Ceiling Mounted Light
Special Receptacle
O-
Wall Mounted Light
-8
aterproo groan au t circwt
Light with Pull Chain (attic)
®
Floor Duplex Outlet
©
Computer Connection Jack
rEF1
Carbon Monoxide Detector
412
Flood Light
Q
Thermostat
m
Electrical Panel
®
Central Vac
�
Electrical Meter
®
Smoke Detector
Ceiling fan
©
Television Jack
FT]
Telephone Jack
A sc
A/C Disconnect
®
I x 4 Florescent Light
®
2 x 4 Florescent Light
R
Speaker Hook -Up
El
Intercom
®= JUNCTION BOX TO SUPPORT A PAN
O = THERMOSTAT LOCATION
B/A = BALANCED AIR
Electric Notes:
I. Use copper wire only, no aluminum.
2. Provide and wire ail required smoke detectors.
3. Contractor to verify location of electrical
service and provider.
4. ALL paddle fans shall be on a rheostat.
S. ALL bath and kitchen receptacles to be GFI protected.
6. ALL exterior outlets to be WP/GFI protected.
1. Recessed cans to be installed per NFPA requirements.
S. AFCI receptacles are required in all rooms except
Kitchen, Bathrooms, and Garage.
9. A/C Return Air Balance Must comply. w/ FBC RM1602
10. A/C Refri Brant lines that are run thru slabs must be
sleeved in i�VC
11. ALL A/C Equipment shall comply with energy calculation
12. All work shall be performed by a Incensed electrical
contractor, the completed system shall be fully operative.
13. Contractor shall pay for all -fees, permits, testing, and
inspections including blower testing where required.
14. All work shall be coordinated with other trades to avoid
interference with the progress of construction.
15. All required insurance shall be provided for protection
against the public liability and property damage for the
duration of the work.
16. Contractor shall guarantee all materials and workmanship
free of defects for a period of not less than two years from
the date of acceptance or certificate of occupancy, or one
year from closing sale of house.
Correction of defects shall be completed without additional
charge and shall include replacements or repair of any
other phase of installation that may have been damaged.
H.B.
Vent _thr_u
206 CFM
IOxlOxl
Opt. PATIO/SLAB
Covered Porch
1
G1iEAT
iy�00M
1
1
Center RegisLairs
on calling fhn
� xlOxl
DINING
ROOM
146 CFM
IOx6x6
SECOND 1/0
BEDROOM
12x12xs j /
B/A Y!J
149 CFM
IOxlOxb
149 CFm
IOxlOx6
L�I
1210
i
/ o
.o I
rAro K
n
COVERED
PORCH
P'IECHANICAL LAYCUT
SCALE: 1/4" = 1'-0"
11. It is not the intent of these plans to show every minor detail
of construction. The contractor shall furnish and install
all items for a complete electrical system and provide all
the requirements necessary for the equipment to be placed in
proper working order.
18. All work shall be done in accordance with the N.E.C. and
shall comply with all local codes and ordinances, and shall
meet all standard requirements of the local electric utility
and telephone company.
19. The electrical system shall be completely and effectively
grounded as required bg the latest edition of the N.E.C.
20. All material shall be new and shall bear underwriters'
labels where applicable.
21. All equipment and panel sizes shall be verified before
ordering. The contractor shall provide circuit routings to
suit the job conditions.
22. Furnish and install all fixtures as called for on the plans
or as selected bg others.
23. All raceways and pipes placed in or through any concrete
slab shall be spaced a minimum of three diameters of the
largest conduit or pipe from any other service.
24. All exposed wire below 9'-1" shall be installed in metal EMT
conduit.
25. Dryer Vents to be installed per FBC RM1502
22' x S4"
Attic Accew
with light 1
L-___
ICJ
12)d2xlO
B/A
150 Amp
Panel
GARAGE
I
I I
I I
I I
I I
I I
I 1
I I
I I
I I
I
I I
#2/0 Aluminum feed
1'/s' Conduit
2" PVC
2" riaid service PPL
ELECTRICA
A/C disc.
qi rop
PANEL
nar15#cartr4%arw'm slab
L RISER
__ Vent_t#�rtL
Soffit
A/C
41
- Contractor shall use AL-CU Landing lugs_ NTS
- Contractor shall torque lugs I.A.W.
manufacturers recommendations which
shall be verified prior to construction
eter
Braden it
Braden AI A, FA
Architects
- Planners
411
S.E. Coconut Avenue
Tel :
(112) 281-8258
Fax :
(112) 281-8283
E-mail:
brad enaia9comcast.net
H.B.
Exhaust Duct
Thru Soffit -
Wire For
Front Post
Light
ELECTRICAL FLAN
0
N
WQnne Building Corp.
Post Light with
Photo cell
Exhaust Duct
Thru Soffit
4" Exhaust
Duct Thru
Wall
Install oulet
under disc.
i shown for
clarity
SCALE: 1/4" = 1'-011
Attic Ventino Calculations FBC 2309.1
Total Attic Space = 2124 sq. ft.
Venting Ratio 1/150 = I4.16 sq. ft. required
THE STERLING REAR
PORCH
Spanish Lakes RIGHT
St. Lucie County Florida
Provide A Continuous Vented Soffit
Date Drawn
5-24-18
Drawn by:
C.C.U.
Checked by:
D.iR.B.
Revisions
Sheet I Comm #
E - I I i6-3oi
OF
B
For Truss to Truss
Connections see
hanger/connector
schedule in engineering
..�,, y,,.y --
Nails must be as
shown. Guide tabs o
Dome angle nails.
SEAT PLATES BY CHAMBERS
to
LO
Cl)
12
4.00 F_
r 8,
12 2.00
i
upset=1/4" heel=3 15/16"
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT 8'
END DETAIL: TYPICAL VAULT
12
4.00 r—
upset=1/4" heel=3 15/16"
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT 8'
TYPICAL END DETAIL
71 INDICATES LOAD BEARING
REQUIRED BY TRUSSES
SUPPLIED BY BUILDER
AT'I A HEIGHT OF 8'-0"
ABi VE FINISHED FLOOR
TRU'.>SES
FOR THE FIRST MODEL SHOULD BE SHIPPED AND SUCCESSFULLY SET BEFORE ANY MORE
TRUSSES
ARE BUILT FOR THAT MODEL.
AL
ARRANGE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR OF
18'- 24'
IN LENGTH
Do not stand on trusses until they are braced per BCSI & properly nailed to straps &
hangers
P�- -----
5PAGING NOTE _
ALL TRUSSES ARE TO BE SET
AT 2'—Or ON CENTER
EXCEPT AS NOTED
AIR HANK=>LIE=R NOTIE=
UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES
ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR
ANY OTHER A/C REQUIREMENTS. THIS MAY BE IN CONFLICT
WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS.
CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR.
All load bearing walls, headers,
beams & lintels must be in place
at indicated height before trusses
A are installed. A
I I I I I
15'40" 7 5' 4" i� 3' 4" _�v 11' 6" K
GARAGE LEFT
OR
A
DONT LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
I
I
I
1
I _
I
ILI VAMS
INVERTED W" WEBS AT CENTER
W19' B.C. PANNEL- LOAD W/ (2)
50# POINT LOADS PER TRUSS FOR AIHIU
.\\`
I\\'=
I
\OMi691\\\\i\\\\\`I\
01
:to
ATA
ATA
ATA
ATA
ATA
ATA
ATS
ATC
FABRfCAMNI EAEMENT
rairssEs caNNor trE STARTED uNrn navgrrro se m s RE]rUR
Th. Waa desalpaon orthe PmpertYwltore d,e tobraaMd ie
Tneaae,.iabd.cwowlrtdcrt..nd+a+"o.: —
,:.Tnraeet we. be made RI :trtd eocordar.s ost Plexnra I'.Thoo of tM truwesbeen �mmererslpned,r ..:wrtaen » W1d b yme«. Tme.t mrich artpan b tuml.hsd '•we. b. alowed..m to cn.n eera Tn..ha�hwe ease csy °!,1Y,,..daybe& repelsraquked,ortoer�Eeoffwt , ._.-
- Tnw hsa to i besearas job sM u riot prapseed for degvery or mupor b not proparW for depvery of ar uyar fi ro.pon ! w f8r.mbero Tna. for bw6p heats due w.Rs
a Ptke a. aiwkm h peraprsph 7 babe b ub)ect w m.ae y C 7; -71cuL A 869 Par howf le for revblon. may b8 dlarped by Chambers Tnom -
. 7: TNr b a PURCHASE ORDER to Ctrernbarr,Trus at the sum alireed tD, V .
et Pie. Imrdce we. be maGr on dervery err pay or aMtrm lama of
dei of fabrkated 4ia.e�s rnmidoe " a"10daad de. 1 bf "My u bw cannot Docapt
adornef+e tee for „eaant a'M0A0d aa"aa to Pay chambera.Truss reasonable
drdee we. be. added krd Harr. na = fwn a, „" ' made. 1-112 x Per deny, eel,
a slpnaturo or bdtlab srry where on this area aorudtartes spreanoa to s1 temm nerom
6 m mWdoragon of Chambers Tnroa erarmg aedR Par thb materla the hemin. unox iliknaly guarantm pgrtrmd when duo of arty err ap brebbd a owed to Climbers Traaa by.say aa4r rsoelWrp maalsf aM the. rnraralpried
Indudlnp ++19,r" fees, If do*g In PsYnte+d for mateda ha merle by thetl» -
'10. In the avant of any tltlpalpn corroomtrrp thla etyeenrent, the Rams hrtdshed hereunder
be S 60ds CartgymFlcrldab.'' Parllee agree daR dre.ple emus (Or any such adton we. '
11.D.agrresponswaleser0W-Nap«,4l ;dardAndit ,an�dad<�ridelw.or, RasponsMiles For Codamrcdarr U.brp fRetel Plate Corprected Wood Tms.os
ANSVrPIIWTCA 4-2002"' ..
DATEp . -
srdNm -
r ;
rori Trttr= . r •
A=Pb��N�regiddPar'9f)511-03"bpeuafttyjlryg�rtraga .
MiRMOP ply trusses must be fastened togefher per engineering
before they are set; failure to do so can reiul&In roof collapse.
Temporary and permanent bracing are required and can am We
and property and Is the responsibility of the truss arector,
'Study the contents of the Information packet Included on delivery
before sating lhasss.
Tm sesnisietbesetandbracedpertleellgn}�pepsf���yg
Trusses must be set plumb and square
Do not set bunks or stack of plywood, roofing material or any
'blhei 21t 010ntrated loads on trusses, this can cause calla
pts
DO NOT SET TRUSSES USING THIS LAyOUT
USE LAYOUT DELNERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
3105 Oleander Aiienue
Fort'Plerde; Florida 34982.6423
see-551-.5932
Fort Pierce 772486.2012 F'ax 771-466.8711
Vero Beach 7M4568-2012 Stuart �772-286-3902
.•�� cw. r"uauQCoaTDlrftQ'r`.AY . • .
Lv Architu,.. ;.,.r Architect's representative's
shay C, Ninq approval is NifT a
"double check" of the contractor.
The contractor shall remain responsible
for checking field measurements and
other construction criteria. Architect's
approval covers general roof shape,
review of truss strapping, and loading on
structure from gravity and uplift loads and
their res trve locations.
92.0/93.2 MITEK 42
DESIGN CRITERIA "` BY
County SA114T LUCIE "Braden A.I.A. P.A.
Building Department ST LUCIE COUNTY
Wind Design Criteria ASCE 7-2010
Wind Design Method MWFRS/C-C hybrid Wind ASCE 7-10
Roofing Material Shingle or Shake
Loading in PSF Roof R.D.L.
0 :: I Top Chord Live 20
R Top Chord Dead 7 4.2
w C Bottom Chord Live 10 Non -Concurrent
w r6 o I Bottom Chord Dead 10 3
o c I TOTAL Load 37 7.2
w y Duration Factor 1.25
d = I Wind Speed 1651'nph
i 0Top Chord C.B. Sheeting by builder.
— Bottom Chord C.B. Sheeting by builder.
N N
Highest Mean Height 12'4)"
ci zt Building Type ENCLOSED
Building Category II:Non Restrictive
Exposure Category C
Barrier Island No
Conforms to FBC 2017
K.U.L.=Hestraininq Uead Load C.B =Continuous Bracin
[BuildinN CRITERIA shown above with the
tment and your engineer.
is the responsibility of the
Her and/or En ineer of Record.
Chambers Truss Inc. Drawing Name: M11412
W Scale: 1 /4 = 1'
73 total trusses, 18 different trusses.
MI 4: RLC ACAD: RLC Reviewed By:
^ Date:11/14/16 Revised:10/23/18
v) FOR
Q WYNNE DEVELOPMENT CORP.
3� -4- �I 6-4" lc 15'-10"
C DESCRIPTION: -7 �,
GARAGE RIGHT G STERLING 176 (a
PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE
18 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT M 11412 s �ajas