Loading...
HomeMy WebLinkAboutBUILDING SITE PLANGulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12 26 ga. 5v crimp metal roofing attached to pigwood deck using #9 x 1.5" wood screws with self sealing washer at 12' o.c. max spacing over ASTM D (type 2) 30 lb Felt underlayment installed with min. 4 side laps and 6" end laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails spaced 6 o.c. at all laps and two staggered rows 12" o.c. in Field. Attach deck to trusses using attachment detail on this sheet 12 SLOPE 14 5/8" thick light textured o O stucco an typical concrete block construction Finish Columns with 5/8" thick x 8"w cut 5/8" thick cut coral coral finished stucco bands finished stucco bands R i G H T E L E V A T I O N SCALE: 114" = F-O" Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11151.12 26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5" wood screws with self sealing washer at 12" o.c. max spacing over ASTM D (type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails spaced L o.c. at all laps and two staggered rows 12" o.c. in field. Attach deck to trusses using attachment detail on this sheet 12 4 SLO� S'-I" T.O.B. 12" 12" C O'-O" = Finished Floor Ll Finish Columns with 5/8" thick light textured 5/8" thick cut coral stucco on typical concrete finished stucco bands block construction ELEVATION NOTES: REAR ELEVATION — Overhangs at 1'-0" unless otherwise noted on Roof Plan — Roof pitch at 4:12 unless otherwise noted - An(g changes to this plan shall be submitted to the architect for approval In writing prior to starting construction. Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12 2L ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5" ASTM D — Return Stucco ALL Bands Into Window or Door. wood screws with self sealing washer at 12" o.c. max spacing over (type 2) 30 lb felt underlayment installed with min. 4 side laps and V end laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails spaced 6" c.c. at all laps and two staggered rows 12" o.c. in field. Attach deck to trusses using attachment detail on this sheet 12 4 1 SLOPE 12" ° ❑ 5/8" thick x 8"w cut ■ 3 coral finished stucco bands 3 77-77-7 5/8" thick light textured stucco on typical concrete block construction =Finished Floor -------------------------------------------- LEFT ELEVATION Product Approval Submittal Affidavit Opening Schedule Swing Doors, Overhead Doors, Sliding Doors. Windows do Skylights Opening Type NOA/FL NUMBER Product Model Manufacturer Glass Attachment method Expiration Expiration Date Design Pressure of Approved Teats 1.2.3 E4 FL# 239.3 Single Hung SH-100 Impact PGT 5/IG" 1/4' dia. tapcorn w/ min. 1 spaced per product approval. min. edge distances specified 3/8' penetration to be Contractor shall adhere to in Product approval + 80.0 PSF — A 16-0330.02 Overhead Garage Door Model 824dth 9'-4" max width IL'-O° max height DAB RAW W Y to cmicretl et a N as ' •fArd , „R/yaaa2 t." ��su'�hwea at y� is siu• x i sir rw Wood ip sera m sh sndvt ss.es ins. a is sa,s dtewa - GC to atmseIa inn... to prsaact sppiwe 10-9-21 + 50.0/-60.0 sf p B FL# 14614.1 Fiberglass Smowogth Pro Jeld-Wen Elco I/4" dia. tapcon with min 1.25" embedment at 3' max from comers and 11.5' o.c. max thereafter in head and iambs. + 50.0 PSF C FL# 251.5 Sliding Glass g Door Series 110 5GD PGT 1" nom Type "GSA " I/4' dia. tapcons w/ an. I / ' snetration to be spaced per product approve. a�itractor shall adhere to min. 2 I/2 edge distances specified in Product approval ± LD.O PSF Product NOA/FL NUMBER Model # Manufacturer Attachment Method TEST Expiration Date Design Pressure of Approved Tests M11lllOI18 FL# 261.1 1" x 2 3/4' x .315' PGT Install per fastener type and spacin a shown in Table IA and IS in product approval on sheet 5 of2. + 58.0 PSF ]'i00f FL# 11451.12 5V Cnmp Metal Roofing Gulf Coast Supply and manufacturing 21 ga. 5v Grim metal roofing attached to plywood deck using #9 x 1.5" isoccl raA ASTM �j 3owit felt sealing d o.cwith max seaside ovlapernd Iaps fastened with corrosion resistant tin ceps and with 1.25' ring shank nails spaced L o.c. at all I and two staggered rows 12' o.c. in field. Attach deck to trusses wing attachment detal on roof plan — 108.3 P5F Siding stucco on Block Soffit FL# 12198.3 Model T4 12" vented Vinyl Soffit Kaycan Install using 2" x 2" battens at L" o.c. screwed to aofrit framing using #8 x 3" wood screws at each truss. Install soffit to battens using II clia. x 1.5" Iona ring shank mails auth S/8" ckahead +55.0/-35.0 PSF Hurricane Panels I have reviewed the above and approved it by my seal below. ( Architect or Engineer of Record ) SCALE: 1/4" = 1'-0" 2" x 4" top plate base -board 12 4 1 SLOPE 1 �2, b351 ST. LUCIE COUNTY BUILDING DIVISI N REVIEWED FOR COM , C, REVIEWED BY DATE PLANS AND PERMIT MUSZ BE KEPT ON JUB SITE OR NO INSPECTION(S) WILL BE MADE ALL MANUFACfUSEB TABLES SHOWING U FACTORS AND SHGC COMPLIANCE yfn{ FBC ENERGY CODE MUST REMAIN ON ALL DOORS AND UNTIL INSPECTIONS ARE APPROVED SCALE: 1/4" = 1'-0" Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12 26 ge_ 5v crimp metal roofing attached to plywood deck using #9 x 1.5" wood screws with self sealing washer at 12" o.c. max spacing over ASTM D (type 2) 30 lb Pelt underlayment installed with min. 4 side laps and L" end laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails spaced L" o.c. at all laps and two staggered rows 12" o.c. in field_ Attach deck to trusses using attachment detail on this sheet 12" P E H. 5/8" thick x 8"w cut coral finished stucco bands ®®� ® ❑e ®®®® Q THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED By FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIRILI 7 11 THE CONTRACTOR OF RECORD, 5/8" thick x 8"w cut coral finished stucco bands 1/8" Thick cut coral stucco over paper backed wire lath nailed to substrate through one layer of 15 lb felt using Sd nails. Substrate to be 19/32" CDX Plgwood nailed at 6" o.c. in field and edges with IOd ring shank galvanized nails into truss webbing. 12" H. Q 5/8" thick x 8"w cut coral finished stucco bands A.F.F. 5/8" thick light textured ��� Finish Columns with stucco on typical concrete 5/8" thick cut coral block construction finished stucco bands FRONT ELEVATION SCALE: 1/4" = 1'-0" 1/2" drywall ceiling on truss bottom cord 1/2" drywall on 2" x 4" studs at 16" o.c. 2" x 4" P.T. bottom plate \ 4" concrete slab with fibermesh OR 6"x6" #10/10 WWM on 6 mil Visqueen over clean compacted termite treated fill Interior Non—Bearina Partition Braden t Braden AIA, FA Architects — Planners 411 S.E. Coconut Avenue Tel : (112) 281-8258 Fax : (112) 281-8283 E-mail: bradenaia0comca5t.net Stuart_ FL 34994 UAACOOOOS2 nts WW nne Building Corp. THE STERLING Spanish Lakes St. 1-ucie County Florida ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP. AND WiLL CONTINUE FOR ONE YEAR FROM THAT DATE PERMITTING INFORMATION (FORM 100) Florida Bwiding Code Residential: Lth Edition and ASCE 1-10 For Wind Loading Budding Design is: Enclosed Risk Categorg: II Wind Velocity: 11.5 mph ultimate Mean Roof Height: II'-O" Roof Pitch: 4.12 Internal Pressure o-e icient: ±0-18_ SubJectability to damage from: Weathering: Negligible Termites: Veru Heavu Width of Roof End Zone: '- " Wind Speed: 145 mph ultimate Wind Exposure Classification: C 08 , TN Adjustment factor for Exposure Height: 1.21 x O.G = 0.124 ASD design Load Combination: ASCE 1-10 Section 2.4 DL+LL; DL+O.LWL; O.LDL+O.LWL Components f Cladding Wind Pressure (NET) Roof Zone: I. +20.6/-32.6 pat Roof Zone: 2. +20.6/-51.0 pat Roof Zone: 3. +20.4/-84.O psf Components t Cladding Wall End Zone Width: 3'-4" Components E Cladding Wind Pressure (NET) Wall Zone: 4.+35.8/-38.1 psf 0= Roof Zone I Well Zone: S. +35.8/-41.8 pat Walls Zone 4 Components d Cladding Wind Pressure (NET) on Garage Door:+32.0/-40.3paf Shear Walls Considered for Structure? Yes Continuous Load Path Provided? ® = Roar Zone 2 es Walla Zone 5 Are Components an Cladding Det� Provided? Yes END ZONE Minimum Soil Bearing Pressure: 2.500 psi, Presumptive: X B9 Test: pal = Corner Zones SEE RODUCT APPROVAL FOR IMPACT PROTECTION FOR OPENINGS Roof Zone 3 ROOF LIVE LOAD: 3-1 paP ROOF DEAD LOAD: 10 pot FLOOR LIVE LOAD: __15 pat FLOOR DEAD LOAD: 10 sf S(ANNFEl3 JOB ADDRESS: '\-\ r�.S\Grp MODEL: Date Drawn : Revisions 5-24-18 REAR Drawn by: PORCH LEFT c.c.U. Checked by: D.R.B. r Sheet I Comm # OF 5 'FLOOR PLAN CRAB TYPICAL NOTES: SCALE 1/4" = 1'-0" POST DETAIL N.T.S. I. Contractor to verify ALL notes and dimensions prior to steel high by 4" diameter steel crash post. Floor proceeding with work. Flange with 4 - 3/8" 2. Contractor to STRICTLY enforce ALL OSHA Requirements. lap a(3/ bolts Into 3. ALL Lumber to be used as Beam, Rafters, etc... to have slab (3/8"t 50 kill steel plate) a minimum 1,400 P.S.I. fiber stress. a 4. No dissimilar metals to touch. 2�5" 2 5, ALL Concrete used for slabs shall be min. 2,500 PSI concrete. o �2" ALL Concrete used for vertical filled cells, cont. tie beams etc.. to m /,- 4 shall be 3,000 P.S.I. concrete and/or 4,000 p.S.l. grout mix 6. Drywall at ceilings shall be leveled and attached to bottom chord 4E of trusses with screws per FBC R102.3.5. o 1. ALL wood in contact with concrete shall be pressure treated. 8. ALL wall dimensions are nominal and not finished wall or stud dimensions. 9. ALL plumbing fixtures to be low flow. 10. Contractor to Provide Drain at water heater in accordance with the current edition of the Florida Plumbing Code. 11. Contractor to Provide a 2'-8" wide door at one bathroom for 12v 2i"1" handicap accessibility requirements. 12. Lowest finished floor to be set by Governing Building Department ` surveyor to set in field. 13. Separation between residence and garage shall be per FBC R302.6 14. Door between garage and residence shall be 1-3/4"t 20 min. rated door w.H. = Water Heater 15. Wall and Ceiling shall have a flame -spread classification of not greater than 200 per FBC R302.9.1 16. Wall and ceiling finishes shall have a smoke -developed index of not greater than 450 per FBC R302.9.2 11. All exposed attic insulation materials installed on attic floors shall have a critical radiant I" x V P.T. Buck nailed to flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation block with case hardened nails materials exposed on the underside of the roof deck or on the attic walls shall comply prior to door attachment with F.B.C. R316 - see permit info box of code edition ..,. 18. Gyyppsum board material shall conform to ASTM C36, C19, C4-15, C514, C630, C931 CW 0, C1002, C104-1,C11-11, C11�8, C12�8, C1395, or C13% and shall be installed according to the following: (FBC R102.3.5) Drywall Thickness Location Orientation Framing Member Max. spacing of fasteners Nail sizing options for installation of drywall into spacing Maximum wood framingmembers Nails Screws 2" x min. thickness Ceding Perpendicular 24" 'I" 12" 13ga 1 3/8" long with 19/L4" head 0.098' diameter x 1 1/4" long annular -ringed or Sd cooler nail ?2 „OR Walls Either IL" 8" IL" 0.080" dia. xx 1 5/8" long with Direction 15/64 head OR Ggpaum board nail 0.084" dia. x 1 5/8" with 9/32" head. Ceding Perpendicular 24" 1" 12" 13ga 1 5/8 011oong with 19/64" head O.Cl diameter x 1 3/8" long annular -ringed or Ld cooler nail OR Walls Either IL" all ILO 0.092"addia. x 11/8" long with Direction OR Gypsum board nail 0.0915" dia. x 11/8" with 19/64" head. Install SGD thru buck into block with 3/14" tap -con with 1 1/2" penetration at 0 o.c. max. from each corner and 20." o.c. max thereafter at head per product approval Use SAC tap -con with 1 1/2" penetration at L" o.c. max. from each corner and 20" o.c. max thereafter at sill per product arc 19. ALL ceramic tile surfaces installed shall conform to ASTM A108.1 thru A108.6, A108.1, A118.1, A118.3, A136.1 and A13-1.1 20. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM C1288, C1325, OR C11-18 and installer I.A.W. manufacturers recommendations shall be used as backer for the wall tile in tub areas and wall panels in Shower areas. 21. Insulation including facings such as retarders or vapor permeable members installed within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics shall have a flame spread index not to exceed 25 with an accompanyin smoke developed index not to exceed 450 when tested in accordance with ASTM E 84. Insulation shall comply with F.S.C. R316. Gulf Coast Supplg and MFG 5v Crimp Metal roofing FL #11651.12 24 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5" wood screws with self sealing washer at 12" o.c. max spacing over ASTM D (type 2) 30 lb felt underiayment installed with min. 4' side laps and L" end laps fastened with corrosion resistant tin caps and with 1.25' ring shank nails spaced L' o.c. at all laps and two staggered rows 12" o.c. in field. Attach deck to trusses using attachment detail on this sheet \ Simpson HETA 20 or equal hurricane anchor at each trues 12 with (10) IOd x 1 1/2" ( 24' o.c.) suppporting nails Max. 4 PRE-ENGINEERED TRUSSES 24"o.c. TYPICAL Ia101ba. uplift at (shop drawings bu manufacturer) Aluminum Drip -V Edge t Fascia '\R-30 blown fiberglass in bottom chord of trusses I/2" drgwall with smooth finish 2" x L" Sub-Faseie Kagcen fun o vent vm i soffit installed ualg Von dro shank x 1.5" long gaiv. roofing nails with 3/8" die. head per product approval - see chart sheet al 5/8" thick light textured stucco on tgpical concrete block construction Two rows of beam block filled with concrete and (1) 95 bar cont. in each row. Substitute precast lintel filled with concrete and (1) #5 bar cont. for bottom row over openings 1/2" drygwall over I" x furringg strips a{ Ili" o.c. with R4.1 Yi-foil insulation on tgpical 8" Block walls All drywall to be installed per FBC R102.3.1 and shall meet all pertaining ASTM codel Mortar to be Type M onlg prortioned per FBC R601.1 and Mortar Jonts shall comply withopFBC R601.2.1. Provide Dur-O-Rack at all wet areas (ex. showers, tubs etc...) T ro 95 bar erw/ 30" overlaplap Fill cell with concrete and at each filled cell () #5 bar vert. (tgpical). Max. spacing shall not exceed Wood 48" unless otherwise noted Base see foundation plan notes for spacing at openings 4" concrete slab with fibermesh OR 611xv #10/10 WWM on L mil Visqueen over clean compacted termite treated fill Grade r _�' I 1II1= III I I:AIIIII „ - I1 I I1 I I_ I''' lI 14' x 14" Concrete footing 14" with (2) #5 bars cost. and #5 TYPICAL SECTION transverse bars at 48" o.c. Scale : 1/2" = 1'-0" Al e1 Masonry Beam Head fixed door sliding door 1 1/2" Sill 5lldlncl Door Detail At Masonry Wall NTS AREA CALCULATIONS Living A/C = 1,414 sq. ft. Front Porch = 153 sq. ft. Rear Porch = 114 sq. ft. Garage = 321 sq. ft. Total Under Roof= 2,124 sq, ft. Total Cubic Ft = 11,192 2" VTR J1L I I I I 21' VTR Mastel JiL Bath 1 I 1Lw. I 2•hr I Lay. _ I q• 1 2' VTR V JIL I I 7' 3• % I aMir. I Ka. sink I Kitchen 2' I I I Lay. 3' W.C. Bath #2 akv. 3• C.O. To Septic PLUMBING RiSER I" x 6" F.T. Buck nailed to block with case hardened nails prior to door attachment \ Masonry Wall gpical Flooring Install SGD thru buck into block with 3/I6" tap -con with 1 1/2' penetration at 6" o.c. max. from each corner and 20." o_c. max thereafter at Jambs per product approval Jamb Window Schedule Mark Size Rough Open. Window Description PRESSURE ZONE I. 4'-Ska"x 5'-3 ia" 54ka"x 43i4" Single Hung ZONE 4 2. C-2%a"x V-3 %a" 15" x 1.3 %4" Single Hung ZONE 4 3. 2'-2" x V-2 1/2" 21k2"x 385's" Single Hung ZONE 4 4. 4'-5%e"x 4'-2Ve" 54%a"x 54ya" Single Hung ZONE 4 ALL Windows to be aluminum windows w/ tint and mullions per elevations. ALL windows to withstand pressures in permit info box on Sheet 1 ALL windows in bathrooms to be tempered All rough opening dimensions to be verified by contractor with manufacturers specs prior t0 construction Door Schedule Mark Size Rough Opening Door Description PRESSURE ZONE A 9'-0" X it -On 108' x 84" Overhead Garage Door ZONE 4 B 31-0" X 4'-8" 41'4"x 83%" Fiberglass Panel - Inswing ZONE 4 C L'-O" X C-8" 14" x 81 %" d;c;;t'" Sliding Glass Door ZONE 4 D 2'-O" X 4'-8" Solid Core - Wood - 6-Panel -Bi-Fold Finished 24" x 81 E 2'-V X C-8" Solid Core - Wood - L-Panel F 5'-0" X 6'-8" Solid Core - Wood - 4-Panel - Bi-Fold G 2'-S" x C-S" x I %4" Solid Core Wood, Steel, or Masonite Door H 2'-8" X 4'-8" Solid Core - Wood - L-Panel U 2`-L" X c-en Solid Core - Wood - L-Panel - Bi-Fold K 2`-8" X L`-e" Solid Core - Wood - 4-Panel - Bi-Fold L I'-L" X L'-8" BI-FOLD ALL Exterior doors to withstand pressures stated in permit info box on sheet 41 GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET #1 All rough opening dimensions to be verified by contractor with manufacturers specs prior to construction lo'-o" 12 10'-0" 12" 09N II�TiAR��r B Q o 0 0 0 0 0 o a o (V ° � EGRESS 12" x 12" Concrete column � ° block filled with concrete and O 12) #1 bars vert. tied Into I OD lintels above Covered Porch l] Provide screen infill below Oif if ti LOJI1011 1100110 ° ° I I I lol°0 ° c MASTER UL= BEDROOM 1 ° ao a� u " . 8 -O" to-9'-8' A.F.F. F m n 8'-0" A.F.F. Vaulted C*eilrng "' a� • Flat Ceiling GRE4"T o ROOM I G O "+ E � � Rod t fielf 1 H_B_ Vanitiq to e i I tv 4 i2 hig r p E 2" x 6" knee -wall 8'-Ot to 9'-8" A.F.F. N rr r O I AC below counter top faulted Ceding CLOSET I DINING is, - - - J ROOM CABINE Rod t shelf 8 /he F` s, UJI o Y _ _ -' \ ATH � I O (] ° Vanity to be F I 34 y2"high O I (410) 9Y4„ 13'-03/4,, 0 Lo O High wall ' Lo <ITCHEN 3'-e° 1 0 Ven Dryer - � � thro h wall 0 L 1-1/2" - c+ i - - 8'-O" A.F.F. Over -hang O N - Flat Ceding ° ° Upper cabinets to D ext rid over Ref. 3'-O"4" 10'-2" O N 2" idler 4'-0" I rI °ef. E BATH , G _ rar� �p� _ O emng -Vent --- Rod tShelf O ° " R-II Satta nolation s N - E w•H. a 1 ® O - - - - 4"0 Steel Ballard # I See detail on this s ae I --- L /O it Provide auto - 24" 22" x 5,, li" O 1 N closer Attic Access 6 1 L°] I with light Q L - - - - - J 22" _ 8'-0" A.F.F. Flat Calling 150 Amp 4 c It Meter _O" 13'-6" Panel m 4 " SECOND to Cq GARAGE E BEDROOM I EGREssY _ m O O -4" A.F.F. ° E MT1 IE31 ° Flat Cedingif cv F\O' o Q o O r-----------------i EGRESS 0 `r Block wall in o 1 garage to be 1 = O ° 1 struck block I T 12" x 12" concrete column block filled I 4 -L 1 0RC with concrete and (2) #1 6ars vert. tied 0 O into lintels aba eLA 1' 2" O chl°O 1010 H01 3'-5" 5'-2" Install windows thru buck into block with 3/16" tap -con with 11/2" penetration at V o.c. max. from each corner and 20." ill max thereafter at ,iambs and 20" o.c. max. Exterior face at head and sill per product approval of wall -\ / \ Buck to be I" x 4" FT Detail at windows I"x4" P.T. Buck nailed to block with case hardened nails prior to window attachment NTS INSTALL VULKEM BLOCK SEALANT ON ALL JAMB, HEADER, AND SILL BLOCK PRIOR TO BUCK INSTALLATION Exterior face Attach buck to block wall with 1/4" die. Elco conic screws with min. 1 1/4" penetration at 12" o.c. max and 4" max from each corner thru 2" x 6" PT Buck Uetail at Uoor crews thru jamb into buck ige and 15" o.c. max and prior to door attachment NTS STRUCTURAL NOTES I. ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN PROPER ENGINEERING DATA FOR DESIGN. 2. ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI BE 3000 PSI OR 4,000 PSI GROUT MIX AT 28 DAYS 3. POISON SOIL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS. NO SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION. 4 GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ 6X6 10/10 WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL (MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH. 5. LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS BEFORE FILL IS BROUGHT IN. FILL MATERIAL SHALL CONSIST OF CLEAN GRANULAR SAND CONTAINING LESS THAN 10% MATERIAL PASSING THE US STANDARD NO. 200 MESH SIEVE. PLACE STRUCTURAL FILL IN LOOSE LAYERS OF 12" IN THICKNESS AND COMPACT EACH LIFT TO AT LEAST 95% OF ITS MODIFIED DRY PROCTOR VALUE. 6• GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE ATTENTION OF THE ARCHITECT. GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR FOUNDATION FLAN 8. SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS 9. DESIGN LOADS ARE AS FOLLOWS: ROOF (DL+LL) = 41 PSF WIND VELOCITY = PER PERMIT INFO BOX ON SHEET #I EXPOSURE =licit 10. ALL REINFORCING STEEL SHALL BE GRADE 60, MEETING ASTM A-16, t A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 301 STEEL. 11• ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE. FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS, SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE. 12. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTING: 3" BEAMS: 1-1/2" 13• LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS. 14. USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1400 PSI I5. ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF 1000 PSI OF NO.2 SOUTHERN PINE, UNLESS NOTED OTHERWISE. 16• ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. FASTENERS TO HAVE MIN. GISS RATING. I. Any changes to plans must be submitted to the architect for approval before proceeding with construction. 2. Contractor shall be responsible for verification of all notation and dimensions before starting construction. 3. Soil conditions assumed to be 2500 psf. Should any other conditions be encountered, the architect shall be notified in writing for revision 4. Verify, all recess thickness at showers, tile, etc.... 5. Contractor to provide filled cell with concrete and 1 45 bar vert. at 48" o.c. max. Provide (1) filled cell on each side of openings upto 5'-11" wide. Provide (2) filled cells on each side of openings from 6'—O" to 9'—I1" and Provide (3) filled cells on each side of openings from 10'-0" and up Contractor to see plans for any other condition used. Foundation Walls shall have filled cells at 24" o.c. unless otherwise noted (see section) L Contractor to provide for Form Board Survey — Form Board Survey to be provided to Truss Company prior to truss construction 1. Contractor to provide for soil test prior to construction and provide a copy of soil test to architect for review prior to construction 8. ALL Reinforcing steel shall be grade 60, meeting ASTM A—l� and A-35 specifications. ALL Anchors to be A-301 Steel. 9. Provide a minimum of 3" concrete protection at footings and 1-1/2" concrete protection at beams for ALL reinforcing bars. #5 bar vert. w/ Thicken edge to 8"x8" 30" overlap SEE TYPICAL with concrete and at each filled cell ECTIONS one 45 bar continuous 4" concrete slab with fibermesh OR GRADE VxV #10/10 WWM on 10 mil Visqueen over clean compacted termite treated fill °D �r IF � f I TYPICAL FOOTIN =1111— 14"w x Mild concrete monolithic I�Ifootmg with (2) #5 bars cont. DETAIL SCALE 1/2" = 1'-0" 4" concrete slab with fibermesh OR 6"x6" #10/10 WWM on 10 mil Visqueen over clean compacted termite treated fill 395 bar cont. Step per ,a foundation plan 2v (2) #5 bars cont, bottom steel 10 L/ DETAIL AT (GARAGE STEPDOWN IT x 12" concrete column block filled with concrete and (2) #1 bars vert. tied into lintels above Top of Tooter 14" below finished floor ... SCALE 1/2" = 1'-0" Verify house slab height in field 30"x30"xl6" concrete column footing with (4) #S bars each way COLUMN FOOTING DETAIL SCALE: 1/4" = 1'-0" Termite Protection for New Construction. Soil treatment used for subterranean termite prevention inside the foundation perimeter shall be done after all excavation, backfilling and compaction is complete. If soil area is disturbed after initial chemical soil treatment area shall be re -treated with a chemical soil treatment including spaces boxed or framed. Treatment must be in accordance with the rules and laws established by the Florida Department of Agriculture and consumer services. Protective sleeves around metallic piping penetrating concrete slab on grade floors shall not be of cellulose containing materials and shall receive application of termicide in annular space between sleeve and pipe. 4" concrete slab with fibermesh OR 6"AV 410/10 WWM on to and Visqueen over clean compacted termite treated fill PORCH SLAB EDGE DETAIL SCALE 1/2" = 1'-0" #5 bar vert. w/ 30" overlap at each filled cell Adjust curb height based on gar. floor slope. 45 bar in curb \ Grade d , 1111= 4" concrete slab with fibermesh OR 6""" #10/10 WWM on 10 mil Visqueen over clean compacted termite treated fill o'-o" ® F.P. 14" 14"w x 14"d concrete monolithic footing with (2) #5 bars Cont. ARAGE CURB DETAIL SCALE 1/2" = 1'-0" 2" x 6" PT wood secured with \ 3/8"dia. x 6" anchor bolt at 18" o.c. overhead door track secured to wood jamb per manufacturer's product approval Garage Door Jamb Detail GARAGE DOOR TO WITHSTAND PRESSURES STATED NTS IN PERMIT INFO BOX ON SHEET #I. SEE PRODUCT APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL. Filled Cell Masonry Column With One 45 From Footing To Tie Beam Conc. Fill To Be 3000 PSI See Floor Plan For Location Single Filled Cell COlumn NTS Filled Cell Masonry Column With One #S From Footing To Beam Each. Conc. Fill To Be 3000 PSI See Floor Plan For Location Double Filled Cell Column NTS 0 v- 14'-O" r- I X--'( I MOTsa 9I 4 "THft&MITTAEJ l --- -r 12° 10'-0" 12" N r----I I ° I i Rear Patio/Slab — 1 to be poured separate lU I 12 _g from the house slab. IL 81 AM 24" °i Thicken footing to FI 24% x Mild x 24"L 'n to 1 under filled cells r under girder bearing. — EJ Ell 19 Iola I I I I O I I I I CJ I I I 1 11OI Rear Patio%Slab to-----------------� be flush with bottom of sliding door recess. FI Slope 1/2" I� I II I IF I I I I II P FI I I I a�34Yzyhgh to be 14" concrete slab with fibermesh OR 6"x6" 410/10 WWM on 6 mil Visqueen over I ° clean compacted termite treated fill I Fl I I I I II I i I I F I V It 1 °• FI I� 1 I�I I FI ° pl ° I 4'-0° i 0 U. Q — 0 O #I ( 4"0 Steel Ballard filled w/ Concrete 0 1 \—> FS > I I col I °I o 10 a� I I V�� I I I C s E✓ ° I o 3 I° O oo� FI _ O I a —FI I — — — ---- - --�C LLI X o a- n- F41 T-2" 12,-6" N �" L — F5 Recess for — — — — i r r ° ° ° ° Garage ISoor °0 O° I °——-- — — — —— 12" x 12" concrete column block fille 9'-0" 3'-5" with concrete and (2) U I bars vert. into lintels above II'-6" 36'-O" R FOOTING SCHEDULE Mark Size Description FI 14"W x 14"D MONOLITHIC FOOTING WITH 2 95 BARS CONTINUOUS F 12"W X 12"D MONOLITHIC FOOTING WITH (2) #5 BARS CONTINUOUS Q 30" x 30" x 16"D COLUMN FOOTING WITH (4) #5 BARS EACH WAY F® 8"W x 8"D THICKEN SLAB EDGE WITH 1 #5 BAR CONTINUOUS F5 14"W With x 14"D Curb at Garage MONOLITHIC FOOTING WITH 2 #5 BARS CONTINUOUS - CURB S 0'-0" Provide #5 bars with min. 48 bar diameters overlap into beam. Tie filled call steel into continuous beam block steel. Provide #5 bar set in pre -cast lintel into beam where length of the opening calls for it. ROOF SHEETING ATTACHMENT DETAIL I. Minimum Nail Size = 8d ring shank (min. 2.5" long) 2. Minimum Screw Size = 48 x 2" 3. Minimum Sheathing Thickness 19/32" COX Pltgwood 4. Use nails or screws bas d on presspre for roof stated in permit info box on t ese plans For zone 3 1Ce Area Edge Field Fastener Max. Pressure Zone 1 411 `" 8d ring shank 45 psf Zone 2 4" 6" 8d ring shank 14 psf Zone 3 4" 4" 8d ring shank 84 psf ** Zone 3a I 6" 6" #8 wood screw 112.5 psf ** Use nails or screws based on pres§ure for roof stated in permit info box on these plans for zone 3 Verify with Plan J Column to Lintel "x 12" nn Block 'J#1 Rebdr Provide Cast -Crete SUB-OB/OT precast lintel set in mortar-. Min. 8" Bearing Provide PT Buck i;; :•i attached per jamb details into filled cel 4" Pre cast sill17 r.� I , I.�.1 :7 i:•: . "^-Poured Filled Call Provide #5 bare with min. 48 bar diameters overlap in filled cell. Tie .diameters cell steel into continuous / factor steel. %..:..',`,:` Concrete Footing (see factor schedule '-" for exact sizes) DETAIL AT WINDOW OPENING IN CBS WALL Scale: 1/2" = 1'-0" �r N SINGLE PLY REAR GIRDER TRUSS Nail 2" x 4" blocking to vert. leg of truss with 10d x 1.5 nails at 4" o.c. Install Simpson MGT into wall using 5/8" dia. threaded rod set min. 12" into wat beam and (22) IOd nails into trues i. Overlap " TRUSS BLOCKING DETAIL Attachment AT GIRDER STRAPPING AT CENTER BEARING POINT NTS 1/8" thick light textured stucco installed per ASTM C 924 over ASTM D tgpe 2 paper backed wire lath nailed to substrate through one layer of ASTM D Tgpe 2 felt paper using 8d nails. Substrate to be 19/37 COX Plywood nailed at 6 o.c. in field and edges with IDd ring shank nails into studs. ulf Coast Suppig and MFG 5v Crimp Metal roofing FL #11451.12 IL ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5' w; d screws with self sealing washer at 12" o.c. max spacing over ASTM D (type 2) 30 lb felt underlayment installed with min. 4 side laps and 6" end laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails $paced 6" o.c. at all laps and two staggered rows 12' o.c. in field. Attach deck to trusses using attachment detail on this sheet oe Additional Precast Lintel tt5 bare e BEAR Lintel Length Bar Length Clear Span u u A Bars 11 u B Bars :''• i 1 i 1 i 1 2'-10" 2'-8" 1' -6" 2,#3 none 3'-4" 2'-2" 2,93 none BF8-OBAT SF8-I1BAT SF8-I13/2T Additonal 4'-0" 3'-101, 2'-8" 2.93 none tt5 bars CLEAT 4'-6" 4'-4" 3'-2" 2,43 none ,e,%1..,�.i, i:•�rr me Row of "H" •.'„r?:: Block Above [; j>, 5'-4° 5'2" 4'-0" 2,43 none .;i.' Precast Lintel .��,irC: 5'-10" 5'-8" 4'-C 2,44 none r el Additional �`. i 6 4 5 -41,2,#4 none tt5 bars 1'-0" 4'-2" 2,45 none 8FI6-IBAT 8FI6-IB/2T e'-4" 7'-10" 7'-0" 2,45 none NOTES: ALL reinforcing steel is grade 40. I. min. coverage of stee1=1.5' 2. min. bearing required 6 ea, end=8" 3. standard for reinf. ateei=ASTM ALI5 TYPICAL LINTEL SECTION ( PRECAST CONCRETE ) LiNTEL SCHEDULE Mark Window or D Unit Width Lintel Size Cast -Crete Specification Rows of 'He Block Above a " Bottom steel 8me Top Steal s17e Max Gravrtg Load (PLF) Max. Uplift Lead (PLF) Max. Lateral Load (PLF) L22 2'-2' 3'-6' 8FO-OBAT 1 #5 3069 1564 1024 L31 2'-1' 3;_B. 4'-O" SFe-OBAT 1 #5 256I 136S 143 L45 4'-5' 5'-10' SF8-OBAT 1 #5 1105 909 339 L50 S'-O" v-6' or8-OBAT 1 #5 1238 835 121 L60 L'-O" T-0 BPS-OBAT 1 85 1011 121 S34 LBO 8'-0" T-4" BPS-IB/2T 1 #5 2 #5 152 Sell 512 L90 T-O' 10'-6' 8P8-I5/2T 1 #3 2 #5 (43 530 401 L90B T-O' 10'-6' BFIL-I13/27 ONE I US 2 85 1533 1189 401 LI00 10'-O" II'-4' 8P8-I5/2T I #5 2 #5 582 494 452 LIOOB 10'-0' 11'-4' 8FI6-I5/2T ONE 1 95 2 #5 13L6 1028 452 L120 12'-0' 13'-4" 8P8-18/2T 1 #5 2 #5 411 428 324 L120B 17-0' 13'-4" BFIL-I15/2T ONE I #S 2 #5 1015 110 324 L140 14'-O' IS' -4" OF16-6/2T ONE I #5 2 #5 1250 L09 254 Llbo IL'-O" 11--4" 1 or8-0/2T 1 #5 2 #5 300 M2 1 144 LIOOB IL'-O" IT-4' 1 8FI6-I13/2T ONE 1 #3 2 #5 1 950 500 1 194 - ALL LINTELS SHALL BE MADE BY CAST-CRETE. - LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE - REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ. REQUIREMENTS - LINTELS OVER 14'-0" LONG ARE TO BE PRESTRESSED, 12 Simpson HETA 20 or equal 4 hurricane anchor at each truss with (10) IOd x 1 I/2' male ( 24" o.c.) sup tft g Max.� 18101bs. a lift Aluminum Drip " Edge t Fasciaatta I/2" 12" t from 2" x 6" Sub-Fasci harm into Kalican full o vent vimgl starlit installed using 1/8' dia shank x 15' long gals. roofing nails with 3/a" dia. head per product approval - ase chart sheet #1 12" x 12' concrete column block filled with concrete and (2) #1 bars vert. tisj_ — into lintels above thicken adge to 8"xS" with concrete and one #5 bar continuous BEYOND Top of Tooter IL" below finished floor on Aluminum rip - Edge E ascia Flash and Counter flash Nail ledger to gable end trusa with (2) IOd [is at each web hi —rib lath vertical wood s to provide .ration Into 3/4' penetration members 5/8" thick light textured stucco on typical concrete block construction Varies - see plan #5 bar vert. w/ 30" overlap at each filled cell Rear Patio/Slab to be flush with bottom of sliding door recess. Step per foundation plan �I a Slope per foundation plan M III III . I I I 1 i 3 T Brace Gable end with 2' x 4" SYP #2 Oft back nailed to bottom Of top chords using (2) IOd nails at each truss PRE-ENGINEERED WOOD TRUSSES e 24"o.c. TYPICAL ( shop drawings by manufacturer ) \R-30 blown fiberglass in bottom chord of trusses I/2" drywall with smooth finish Two rows of beam block filled with concrete and (1) #5 bar cont. in each row. Substitute precast lintel filled with concrete and (1) #5 or cont. for bottom row over openings 1/2" drgwall over I" x furringg strips of 14" o.c. with R4.1 pi -foil insulation on typical 8" Block walls All drywall to be installed per FBC R?O: and shall meet all pertaining ASTM codes. a Mortar to be Type "M" only proportioned and Mortar goints shall comply with FBC F Provide Dur-O-Rock at all wet areas (e), Fill cell with concrete and (D 95 bar vart. (typical). Max. spacing shall not exceed Wood 48' unless otherwise noted Base see foundation plan notes for spacing at openings 4" concrete slab with fibermesh OR VxV 910/10 WWM on 6 mil Visqueen over clean compacted termite treated fill I I I__I I I l=l I III__I I I 111=1III— \ FI 14" Ical SeCtIOn at Front Fort a a as s O� rn tY C: <i�is ° a a a 2s a ai 0o a v pQ EC= to to sy F_ El Brace Gable end with 2" x 4" 5YP #2 min. aft back nailed to bottoms of top chords using (2) IOd nails at each truss r FBC R601.1 D1.2.1. showers, tubs etc...) R W :ri: Strap truss to wall using Simpson MGT with Simpson HETA 20 5/8' dia. threaded rod with min 12" embedment hurricane anchor at each truss into beam (22) IOd truss leg either wet set or in epoxy with nails Into truss. Add blocking to per detail on this sheet ( 24" o.c.) HETA 20 1810 supporting Max. Ibs, uplift 6� was 0 ON wroraLl VIA Gulf Coast Supolu and MfG 5v Crimp Metal roof,noF s rows with self sealing washer at 12" o.c, max a )of 2) 30 lb felt underla=ainntsta edc with min- 4' side laps and V end i astened with corrosion n aos and with 1.25' ring shank nails no attachment is sheet WE PANE NEW@ Fe f: OOF FLAN I W Ln L 0) Q LURE IV LU U-C: W in Z vl rya z LU d_U I W fL O 1L u) 0 LU — OVERHANGS AT 1'-0" UNLESS OTHERWISE NOTED ON THIS SHEET — ROOF PITCH AT 4:12 UNLESS OTHERWISE NOTED ON THIS SHEET — TRUSS SHOP DRAWINGS TO BE PROVIDED BY MANUFACTURER — ANY CHANGES TO THIS PLAN SHALL BE SUBMITTED TO THE ARCHITECT FOR APPROVAL IN WRITING PRIOR TO STARTING CONSTRUCTION. — ALL TRUSS TO TRUSS CONNECTIONS BY TRUSS MANUFACTURER — ARCHITECT TO REVIEW TRUSS SHOP DRAWINGS PRIOR TO CONSTRUCTION FOR LAYOUT AND UPLIFT VERIFICATION — CONTRACTOR TO PROVIDE FOR FORM BOARD SURVEY AND TO PROVIDE FORM BOARD SURVEY TO TRUSS COMPANY PRIOR TO TRUSS CONSTRUCTION PANEL "A" Poles BR Load Wire Description tire# tire# Description Wire Load BR Poles 2 40 l.0 kw #e A/C comp 1 2 AHU #10 3.6 kw 30 2 3 4 2 30 4.5 kw #10 40 gal. waxer HTR 5 4 Range #6 12.0 ka 50 2 l g 1 20 L8 kw #12 Pump 9 10 Dr er #10 9.0 kw 30 2 11 12 1 20 I.5 ke #12 13 14 Dishwasher #12 1.2 kw 20 1 1 20 1.5 kw #12 Microwave 15 16 Refrigerator #12 1.2 kw 20 I i 20 1.5 kw #@ Kitchen S.A.C. m 18 Racepts #12 20 I 1 20 1.5 kw #12 Kitchen S.A.C. 19 20 Racepts #12 - 20 1 1 20 L2 kw #12 Clothes Washer 21 22 Recepts #12 - 20 1 1 20 0.81 Its #I2 Garage Door Opener 23 24 Recepts #12 20 1 I 20 1.4 kw #1225 21.Racapis #12 20 1 I 20 1.92 kw #12 Zl 28 Recepts #12 20 I 1 20 #12 General Lighting 24 30 Racepts #12 20 1 1 20 #12 General Lighting 31 32 Recepts #12 20 1 1 20 #12 General Lighting 33 34 Exterior GFCI #12 - 20 1 1 20 #12 General Lighting 35 Bathroom GFI #12 ZO 1 1 20 #12 Smoke Detectors 3l 38 General Lighting #12 - 20 1 1 20 #12 Bathroom GFI 39 40 General Ligh" #12 - 20 1 s are 11 42 S are PANEL "A" LOAD CALCULATION SHEET Load Description at . Watts Total(Watts) General Lighting (3. watts sq Pt,) Small. Appliance, Circult(a) , , , , , , , , , ,,, , , , , ,, , , , , , , , , , , ,, .Range .. .................. .................. ........... .. Refrigerator ................................ ................. Microwave ........................ ....................... .... ,Dish . Washer ................................................... ......................... .............. Clothes,.Dryer................................................ .Water. Heater ................. ........... Water. Pump ................................................... Garage. Door .Opener .... . .......... .. . 1135 3 5,205 2 1,500 3.000 1 12,000 12.000 1 1.200 12OO 1 1500 1500 1 1,200 1.200 1 1200 1200 I 5,000 5.000 1 4 500 4,500 1 1,800 1800 1 810 810 Total Watts 311415 First 10000 Watts e100% 1 10,000 10.000 Remainder 21.415 940% 1 O 10,966 Electric Heat or A/C 10,000 945% 1 10.000 10,000 Calculated Load Watts 30,9LL Voltage 240 Calculated Wattage Divided by Voltage = Total Amps 129.03 Panel Size Required = 150 Amps r Electrical S mbol Legend S Single Pole Switch ® Recessed Can Light S3 Double Pole Switch ® Eyeball Recessed ills Push Button Switch Exhaust Fan Duplex Outlet Ceiling Mounted Light _0 Special Receptacle C- Wall Mounted Light mmme W=1 ground fault circuit Light with Pull Chain (attic) ® Floor Duplex Outlet @ Computer Connection Jack Carbon Monoxide Detector 4& Flood Light TQ Thermostat m Electrical Panel Central Vac rcEi Electrical Meter ® Smoke Detector Ceiling Pan ® Television Jack Telephone Jack nc Disc A/C Disconnect ® I x 4 Florescent Light ® 2 x 4 Florescent Light s Speaker Hook -Up I❑ Intercom 14"1 CFM IOxlOx6 149 CFIs IOx10x6 `1t e� IB2�Axl0 9 CFM Vent_t#�ru ___- SON 1t �ATH E l� Covered Porch I G R E,4 IT ROOI ( I 12xl2AO B/A e.i C nter Registers a 1 208 C o� calling fan 208 CFM ,_1 IOxIOx I \"x IOxlOxi N IDI o � I 12" DINING ROOM 73 / ssamr� ,, Attic Access with light I • 150 Amp GARAGE r--------------- ®= JUNCTION BOX TO SUPPORT A PAN O THERMOSTAT LOCATION �IECH/4NIC�4 Y O U T B/A = BALANCED AIR Electric Notes: SCALE: 1/4" 1'-0" I. Use copper were 2g11 no aluminum. 1-1. It is not the intent of these plans to show ever minor detail 2. ContProvra and were ail required smoke detectors. of construction. The contractor shall furnish and install 3. Contractor to verify location of electrical all items for a complete electrical system and provide all service and provider. 4. ALL addle fans shall be on a rheostat. the requirements necessary for the equipment to be placed in p F. proper working order.. ALL bath and kitchen receptacles to be GFI protected. 18. All work shall be done In accordance with the N.E.C. and 6. ALL exterior outlets to be WP/GFI protected. shall comply with all local codes and ordinances, and shall 8. AFCI receptacleess are required in all rooms except 1. Recessed cans be installed per NFPA requirements. meet all standard requirements of the local electric utility Kitchen, Bathrooms, and Garage. and telephone company. 9. A/C Return Air Balance Must comply w/ FBC RM1602 in 19. The electrical system shall be completely and effectively sleeved i C grounded as re 10. A/C in Brant lines that are run thru slabs must be the latest edition of the N.E.C. Vrequired b y 11. ALL A/C Equipment shall comply with energy calculation 20. All material shall be new and shall bear underwriters' 12. All work shall be performed bg a licensed electrical labels where applicable. contractor, the completed system shall be full operative. 13. Contractor shall pay for all -Pees, permits, testing: and 21. All equipment and panel sizes shall be verified before inspections including blower testing where requiredd ordering. The contractor shall provide circuit routings to 14. All work shall be coordinated with other trades to avoid suit the Job conditions. interference with the progress of construction. 15. All required insurance shall be provided for protection 22. Furnish and install all fixtures as called for on the plans against the public liability and property damage for the or as selected bg others. duration of the work. 16. Contractor shall guarantee all materials and workmanship 23. All raceways and pipes placed in or through any concrete free of defects for a period of not less than two years from slab shall be spaced a minimum of three diameters of the the date of acceptance or certificate of occupancy, or one largest conduit or pipe from any other service. year from closing sale of house. Correction of defects shall be completed without additional 24. All exposed wire below T-I" shall be installed in metal EMT charge and shall include replacements or repair of any conduit. other phase of installatron that may have been damaged. 25. Dryer Vents to be installed per FBC RM1502 SECOND BEDROOM j � 112x12x8 x-�x B/A H.e. Vent thru Soffit MASTER BEDROOM i y a 12 Exhaust Duct Thru Soffit 4" Exhaust Duct Thru Wall W.P. G Install owlet under disc. /" N 's not shown FJ clarity COVERED PORCH of A/C disc. AM #2/0 Aluminum feed MC I ih" Conduit � PANEL M TE AHU 2" PVC ( FPL 2" rigid service FPL Bare #L coppsf wire g to #5 cont.' 4%ar in slab ELECTRICAL RISER - Contractor shall use AL-CU Landing lugs- NITS - Contractor shall torque lugs I.A.W. manufacturers recommendations which shall be verified prior to construction A/C °$Jo-r ZL�6JbAB ON THIS PERMIT / Covered Porch Inl 1 � I GFI ..� I (thl1 arbon G R E ,t T etector ROOM I I I I II II II II I I / DINING ROOM I I i� I y� /I KITCHEN I' - WL .-H. §mgkIs ( CA/r®/4s Monoxide Detector /24" 3'-2" 3-2" Combo 8 Sop-- B 4, T1 50 CFM 4 GF N 42"h GPI 22" x 54" , 1�..�Op Cente Attic with Access es st L L t- 15 0 AMR Optional Meter Panel PCq panel location Pull chainl � fight in attic GARAGE 4211h GFI CLO Garage Door Opener r------------- l I I I I I I I I I I I I I I I I I 1 I I I I I I /i\PB COVERI<P1' F-T Pb12-C H ELEC i RICAL PLAN v SCALE. v,. Braden It Braden AIA, FA Architects - Planners 411 S.E. Coconut Avenue Tel : (112) 281-8258 Fax : (112) 281-8283 E-mail: brad enaiaOcomcast.net Attic VentInCl Calculations FBC 2309.1 Total Attic Space = 212-4 sq. f t. Venting Ratio 1/150 = 1-4.16 sq. ft. required Provide A Continuous Vented Soffit Post Light with Photo cell I 6'-3" a� Exhaust Duct �Thru Soffit Wire For Front Post Light Wynne Building Corp. Date Drawn ; Revisions ; Sheet 5-24-I8 THIS STERLINGREAR Drawn by: PORCH C.C.U. E - Spanish Lakes LEFT Checked by: St. Lucie Count(J Florida D.R.S. OF 5 Comm # A=LIFE SAFETY WARNING This symbol identifies life Safety Warnings that should be read given special attention �y all persons installing trusses. I I 30' Span or less Is 30' to 60' Span 0 degrees Spreker ar or Igss �- j /2 ' a9—APProx 2/3 to _� T g Line span Opprox. �i^e t/2 of Span REFER TO BCSI REFER TO BCSI Truss must be set this way ifcrane used. Truss must be set this way if crane used. l Truro i. an e.—Plc. your true. may not match. This is an example, truss may not match. �nsist crane operator sets truss this Iway Insist crane operator sets truss this way. MULTIPLE PLY TRUSSES MUST BE ASTENED TOGETHER PER ENGINEERI BEFORE SETTING. REFER TO ENGINEERING DRAWING TO DETERMII ® IF MULTIPLE PLY. For Truss to Truss Connections see hanger/connector schedule in engineering package) Carrying Girder Nails must be as shown. Guide tabs Dome angle nails. SEAT PLATES BY CHAMBERS z to a a 12 4.00 r— 12 2.00 8� upset=1/4" heel=315/16" PLUMB CUT END 2 x 4 Top Chord WALL HEIGHT 8' END DETAIL: TYPICAL VAULT 12 4.00 r- upset=1/4" heel=315/16" PLUMB CUT END 2 x 4 Top Chord WALL HEIGHT 8' TYPICAL END DETAIL INDICATES LOAD BEARING REQUIRED BY TRUSSES SUPPLIED BY BUILDER AT A HEIGHT OF 8'-0- ABi VE FINISHED FLOOR TRUSSES FOR THE FIRST MODEL SHOULD BE SHIPPED AND SUCCESSFULLY SET BEFORE ANY MORE TRUSSES ARE BUILT FOR THAT MODEL_ A ARRANGE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR OF 18'- 24' IN LENGTH ,A Do not stand on trusses until they are braced per BCSI & properly nailed to straps & hangers - -- T, 5PAGING NOTE ALL TRUSSES ARE TO BE SET AT 2'-0) ON CENTER EXCEPT AS NOTED AIR HAIV�1—�F� hJOTIE= UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR ANY OTHER A/C REQUIREMENTS. THIS MAY BE IN CONFLICT WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS. CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR. All load bearing walls, headers, beams & lintels must be in place at indicated height before trusses A are installed. A 14' 22' I I ) 1 I I�I�Imi120 nimII��I�I F I 0010010,11111 AA N/_ Miss WORD0041 Islas PAP 1 GI e `V"WEBS AT CENTER IS 1 i TRUSSADS PER 10 �'_ 110, PAN P" 11100 �A I V L I C, Lfl DONT LIFT TRUSSES WITH SPANS LONGER THAN 30' BY THE PEAK. CONSULT BCSI 22' 14' I I I r INVERTED'V' WEBS AT CENTER W/9' B.C. PANNEL LOAD W/ (2) 50# POINT LOADS PER TRUSS FOR AnVU NIMI=IIII� I A3 I 1 1 A4 I 1 AS 1 A5 1 1 - - - A5 1 1 t AS A5 1 AS 1 AS ATA ATA ATA ATA ATA ATA ATA ATB ATC BHA 0 FThm ABRICATION AGREEMENT UesE9 CANNOT eE IFTARTED UIML TaEaseDs Wei deealpdon otthe l)h)P6 p whuenee m,..,, tva bRETMRNED made �in , �re.�e at ilt, ,� demta, t,..t 1,mar 1, o l� tla d!9gta'tt by04 to wis M dNialekrn It tlds IeYold fbkr have been vebytry teWerslWtedtAAie Witten riada a provided by amII1marm cn.me.ts rlun Y tn. andenVn.d rb.t wi1tM, notloe a b.nhh.d Cn.rnba. etm.rdisB b.ve flea. bue,e d•r. a wNa, gin repaba regWrad arm sutts9Wm orhecito job it is•reoWta"�bydelivelyPortion �cnr.T la.n,e')"°rtht�n,mthe job alto for dsrml,e aa�)othe rysr b rospawlpte {eraddilloniiii N Tnwq vAl be resporgl6le for duony.Njab eIt. to jobeftag riot for daItVa,r rc Cbtine m roaF nePonemte m =Tnw mar m rbqw 1. ria pnv*d mofIICe ae QI01N, � paragrepl, T bebW IU ng �Yotd A St 0 (Mf tiwnAs mr rsNebrl. a' m�• e made ob 6 a PURCHASE tD. or If ORDER m �Trues '•Ifrv' • t> . t wta ee mWe oa err w Petenft Of y of Abrlcated buue., TM tsM ay. be made at .dnedided dale bf "my M byer cenrrol accgl• fee 1'r wpodBty t, every WMWned spree. m PaY Chambem,Tirim nw mbb gip• wa be added fo . ,.Over' OflpoWma i t hot III made. t•t4 %Per month se,4. &j%W eorinh�ea m feeh..tao, da.a;, ,teatmermm.bereb, 6 In cauWeratlor, of Gwnlxn role. eyder.*V age for fhb maee<W the andenlign.d WMIWIngly guarwdll" PaYeient when due of any and all kxWbfedi,e.. owed to *W"*s Tmn by.•nY smey rsedWp metabd end the pay such Indlebtilidnessk,Gutllnp •14?meys face, If detest In Prymaa tau" aWbe to by e,e10. In the . ny 11110stIon Or pv,,** � "o hweln, 00f�r"tng � apr•emem the Item. MNsbed hen under the Patke aSaint Loeb Couittly, paide.g ee tlut thevwm (Or anti, such action will b i Daegrt r porptt are txr'Nationat stmdam And Remnurended guidelines on kNsvrtemrlles For Catemxtlp, lA V Metal Plate Corviected Wood Tnueee 1NSVfPWVTCA4-2ugQ"" .. DATEp sroNm - F� _—�TTTLE - • , , .., a;nsidsrbtrma rbars*#odperwBCE 9-03"bplageliijuybdanape . Muttlpla ply trlrases must be fastsntsd together perOng lneedng r>store they are sets failure to dos* can reiulti roof collapil e. Temporary and Permanatst bm g are required and can saw Itre and property and Is the respolnalbtilgr of the t rini s erector, Study the contents of the Infom a Ion packet Included on delivery before setting buss". 7hsseenittetbeaatardbracedperdelsigrtDpinhier kr$ Theses must be set plumb and aquars Do not set bunks or stack of plywood, rooting material or arty poi cob"n rated loads on tnimses, this can cause collapse. DO -NOT SET TRUSSES USING THIS LAYOUT USE LAYOUT UE AFEREG yulrrl TitussEs TO SET TRUSSES CHAMBERS iT'RUSS INC _ 3106 Oleander Avenue Fort Plerce; FIOrlda 3082-6423 800-551'-5932 - FortPlerce 772-46ti-2012 Fax e 7iZ-485.8711 Vero Beach 772-5041 12 $t Rua¢ Ns representative's u'-'• nta... nYwuCGtlQTpll a )^"­g approvA. is NOT a iOu a check" of the contractor_ +e contractor shall remain responsible easurements and for checking fists m other con 5trUction Criteria. Architect's approval cowers ,general roof shape, review of 'trap ra structure from 't pping' and loading on g and uplift loads and the res c ve locatio Approved 13 / - .._—.__�� 92.0/93.2 MITEK 4.2 Uate:__ : /6Bradc - DESIGN CRITERIA, '`a jA"A.'—A. f' County SAINT LUCIE Building Department ST LUCIE COUNTY Wind Design Criteria ASCE 7-2010 Wind Design Method MWIFRS/C-C hybrid Wind ASCE 7-10 Roofing Material Shingle or Shake Loading in PSF Roof R.D.L. 'o d I Top Chord Live 20 m s Top Chord Dead 7 4.2 on e Bottom Chord Live 110 Non -Concurrent Bottom Chord Dead 10 3 c TOTAL Load 37 7.2 ` d, Duration Factor 1.25 w m a Wind Speed 165mph cc 0 Top Chord C.B. Sheeting by builder. 0 Or Bottom Chord C.B. Sheeting by builder. to Highest Mean Height 12'-0" v Building Type ENCLOSED Building Category II:Non Restrictive Exposure Category C Barrier Island No Conforms to FBC 2017 rc.u.L =rcesvammcr ueaa Loa. c;.B, =Continuau Bracin Verify DESIGN CRITERIA shown above with the building department and your engineer. Design Criteria is the responsibility of the Building Designer and/or Engineer of Record. Chambers Truss Inc. Drawing Name: M11412 W Scale: 1 /4 =11 73 total trusses, 18 different trusses. MI 4: RLC ACAD: RLC Reviewed By: �^ Date:11/14/16 Revised:10/23/18 I I I I I I I I I I v J FOR 15'-10• ' S' 4• I 3' 4• ' 1r 6- I ' ire• ' 3'-a• ' S' a• WYNNE DEVELOPMENT CORP. GARAGE LEFT GARAGE RIGHT DESCRIPTION: STERLING PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE 18 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT M11412 q is fgwd'� "• /II�I�Ii111�1119� 11 11 11 0A AV IVA I�I�I�I�I�I�I®Ifs