HomeMy WebLinkAboutFIELD DENSITY TESTFEDERAL
?'UN 1 9 2006
1798 AGORA CIRCLE S.E. SUITE 5
PALM BAY, FLORIDA 32909
250 S.W.13TH AVENUE
POMPANO BEACH, FLORIDA 33069
FIELD DENSTTY TESTS OF COMPACTED SOILS
DATE: 6/14/06 ORDERNO: 06-3122 PERMITNO.
CLIENT: STEVE JOHNSON TRACTOR SERVICE
ADDRESS: 554 S.W. COLUMBUS DRIVE, PORT ST. LUCIE, FLORIDA 34953
PROJECT: PROPOSED RESIDENCE BUILDING PAD LOT 21, BLK 64, UNIT 8, INDIAN RIVER ESTS.
ADDRESS: 5609 SUNSET BLVD., FORT PIERCE, FLORMA
DESCRIPTION: BROWN SAND W/SOME CLAY & TRACES OF SHELL FRAGS
LOCATION: N.W. CORNER OF PAD -. _ """"`y
LOCATION:
FIELD DENSITY METHOD AS.T.M. D-2922
DRY DENSITY P.C.F. IN THE FIELD
105.2
105.4
105.7
%MOISTURE
9.8
9.9
10.1
% COMPACTION IN THE FIELD
95.0
95.2
95.4
% COMPACTION REQUIREMENT
95%
PROCTOR VALUE, P.C.F.
110.8
OPTIMUM MOISTURE, %
12.8
LABORATORYNO.
P-2962
DEPTH ININCHES
12
REMARKS: SOD. NOT TESTED BELOW FOOTINGS
TESTED BY.
CHECKED BY:
Respectfully submitted,
WISSAM S. N f"A P.E.
As a mutual protection to clients, the public and ourselves, all reports FEDERALEN G & TESTING
are, submitted as the confidential property of clients, and authorization FLORIDA REG. #39584
SL
KM
for publication of statements, conclusions or extracts from or regarding
our reports is reserved pending our written approval.
I
A density, test determines the degree of compaction ofthe tested layer of material only. A density does not replace a soil bearing capacity determination.