HomeMy WebLinkAboutFIELD DENSITY TESTFEDERAL ?'UN 1 9 2006 1798 AGORA CIRCLE S.E. SUITE 5 PALM BAY, FLORIDA 32909 250 S.W.13TH AVENUE POMPANO BEACH, FLORIDA 33069 FIELD DENSTTY TESTS OF COMPACTED SOILS DATE: 6/14/06 ORDERNO: 06-3122 PERMITNO. CLIENT: STEVE JOHNSON TRACTOR SERVICE ADDRESS: 554 S.W. COLUMBUS DRIVE, PORT ST. LUCIE, FLORIDA 34953 PROJECT: PROPOSED RESIDENCE BUILDING PAD LOT 21, BLK 64, UNIT 8, INDIAN RIVER ESTS. ADDRESS: 5609 SUNSET BLVD., FORT PIERCE, FLORMA DESCRIPTION: BROWN SAND W/SOME CLAY & TRACES OF SHELL FRAGS LOCATION: N.W. CORNER OF PAD -. _ """"`y LOCATION: FIELD DENSITY METHOD AS.T.M. D-2922 DRY DENSITY P.C.F. IN THE FIELD 105.2 105.4 105.7 %MOISTURE 9.8 9.9 10.1 % COMPACTION IN THE FIELD 95.0 95.2 95.4 % COMPACTION REQUIREMENT 95% PROCTOR VALUE, P.C.F. 110.8 OPTIMUM MOISTURE, % 12.8 LABORATORYNO. P-2962 DEPTH ININCHES 12 REMARKS: SOD. NOT TESTED BELOW FOOTINGS TESTED BY. CHECKED BY: Respectfully submitted, WISSAM S. N f"A P.E. As a mutual protection to clients, the public and ourselves, all reports FEDERALEN G & TESTING are, submitted as the confidential property of clients, and authorization FLORIDA REG. #39584 SL KM for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. I A density, test determines the degree of compaction ofthe tested layer of material only. A density does not replace a soil bearing capacity determination.