HomeMy WebLinkAboutSURVEYS----- --- -- --- EP --- ---- Savanna Road
CL (50' RIght—of—way ,x. 20�avemenf - --
N 90'00'00" E 165.00'
• (NGVD 1929) QpEP �titi I
EL-17.50
SET PK NAIL
in ' t5 N I
±CENTER OF SWALE
N 90'0(Y00" E 100.00' t
FND 1)
1/2" IPin
,
, q
,
i
i
i
/
o
/
ui
_MIN, SETBACK REG.
I FRONTqr`)�-5-
SIDES q• S1
- -
-- ctiA$gI-@_ES u
LOT 1
w
W
a
ZNG'
TECH.
(OCCUPIED)
e
o
FFE=19.39
CD
I Y
LOT 21
SEPTIC/DRAINFIELD
IN REAR &OVER
0
(VACANT)
75' AWAY FROM
O
O
PROPOSED WELL -
in[
WELL IN FRONT OF
' t
LOT (NO CONFLICT)m
\
6' WOODEN 10 PROPOSED WELL
FENCE (CLEAR) N .y5 I )
, I—
PROPOSED
12' X 39'
,' o
+ I 22'
DRAINFlELD
L
39-
EPTIC
��
6 36.17'
------ f
,
\
�S
tib°-
PROPOSED ;
COVERED
M
3.00' 4
ENTRY �
_
Ci
M
\
d
i
PROPOSEDN
o ONE—STORY \ j
a RESIDENCE 1
(Susanna
!L�
9
06 6
�0
o w
00�2
0
O o
}-------ADD*
------
Iw
0
13
0
00
w
i v! W �
Ic
-33• C,
0
C w
0 0
Y'
in
M
PROPOSED
16' DRIVEWA
�1{
I� I
1
33.00'
,
�'
i
h'l
-to
N 90'00'00" E
' 125.00'
"N�;I
40.00" SET
fV
LLJ 0
0 H
LOT 22
/
EXISTINGG4
PK
NAIL
~
o_ < o 2
I
o
(OCCUPIED) /'
I
I
x
O
v w g a o? v
o
FFE=20.84 /
o
J
0 LL a 1n F
LL n
I
SEPTIC/DRAINFlELD IN REAR & OVER
I
W 2 of
75' AWAY FROM PROPOSED WELL EXISTING WELL LOCATED /
LEGEND
CERTIFICATION
IN FRONT OF LOT (NO CONFLICT) /
I hereby certify that the survey represented hereon was performed under
FIRE HYDRANT
� =
WATER VALVE
my supervision and it complies with the minimum technical standards, as /
0 =
WOOD POWER POLE
PUDE=
PUBLIC UTILITY &
set forth by the Florida
Board of Surveyors &Mappers in Chapter
=
TELEPHONE RISER
DRAINAGE EASMENT
61G17-6 of the Florida
Administrative Code, pursuant to Section 472.027,
♦ =
WATER METER
FIRC =
FOUND IRON ROD & CAP
Florida Statutes, and further that th4a"o'ble, above ground
E—=
POLE ANCHOR
it =
CABLE TELEVISION RISER
encroachments unless shown or note
FND =
FOUND
OHE =
OVERHEAD UTILITY LINES
WPP =
WOOD POWER POLE
IR =
IRON ROD
WM =
WATER METER
SIRC =
SETIRON ROD & CAP
JUNE 8, 2006
CL =
CENTERLINE
R/W =
RIGHT-OF-WAY
Date of Signature
B. BENNETTD
EP =
EDGE OF PAVEMENT
P =
PLAT DIMENSION
=DELTA
ANGLE
M =MEASURED
DIMENSION
urveyor & M pper
L =
ARC LENTH
UE =
UTILITY EASEMENT
Florida Certificate No. 6 53
R =
RADIUS
® =DRAINAGE
MANHOLE
LB No. 7235
y 9PP=
SPOT ELEVATION
(I =
SANITARY SEWER MANHOLE
SIGN SITE PLAN APPROVED f
SUPERCEDES ALL PRE1
010AIC C a
Location Map
(Not To Scale)
SCANNED
BY
St. Lucie County
LEGAL DESCRIPTION:
All of LOT 21, BLOCK 64, INDIAN RIVER ESTATES UNIT EIGHT, as
recorded in Plat Book 10, at Page 73, of the public records of St. Lucie
County, Florida.
LOT AREA: 12,991 Sq. Ft.; 0.30 Acres±
STREET ADDRESS: 5609 Sunset Boulevard, Fort Pierce, Florida
i SURVEYORS' NOTES:
1. Bearings shown hereon are based on the centerline of Sunset Boulevard
as platted and bears SO'00'00"E.
- 2. Written dimensions take precedence over scaled dimensions and distances
3 are not to be scaled for construction and/or design purposes.
7 3. All distances and bearings are as field measured and are coincident
with "PLAT" and description data unless otherwise noted.
4. This drawing is not valid without the signature and original raised seal of
a Florida licensed Surveyor & Mapper.
5. This survey is based upon a description furnished by the client, there
has been no search of the public records done by this office.
6. Property lies in Flood Zone "AH17" as scaled from the National Flood
Insurance Program Rate Map, Community Panel Number 12111CO281 F, with
an effective date of August 19, 1991.
7. City water & sewer are available in this area.
8. Elevations shown hereon are based upon an assumed datum.
9. This plan information to be verified by contractor to construct*on_g�
CERTIFIED TO: 0
EARL TAYLOR;
BANK OF AMERICA; JUN 13 2006
COASTAL LAND TITLE CO. and
LOURAN BUILDERS. SELUCIECOUNTY HULTHDE ARTMENT
Revised: Added existing well, JS, 12-07-05. ENVIRONMENTAL HEALTH DIVISION
Revised: Changed proposed house plan, JA, 06-08-06.
Date of Last field work:07/07/2005
Boundary Survey & Site Plan
!� le n ett Prepared on the order of:
Bennett Surveying + Mapping Louran Builders
439 S.E. Port St Lucie Boulevard Unit 107 Field: LM JD Job No.: 05-0703
Port St. Lucie, Florida 34984
tel: 772.336.4933 fax: 772.336.8689 Drawn: JS Date:09�14�2005
email: wbennettdd®cs.com Scale: 1"=20' Sheet: 1 of 1
1'
EP
Savanna eRoad
N 90'00'00" L 100.00, —�
6� 5.00'
BENCHMARK%I
(NGVD 1929)
p1
1�'t' EP
ry� ;
1• ;
ry0
,1
EL=17.50
• SET PK NAIL
N
I
xo
;
..
N I
� �
±CENTER OF SWALE 1
—
N
90'00'00" E 100.00'
S3
I �g6
_
FND
ND
p 9'2i. p
\
IP
,
90•
�
00 ��
tS
0
0 "moo.
1
- 4 00
,
w
x -
o
O
----
59 0'
---------=-----
-- --- - --- ---- --
36.-
---------
---
ayy
--- ss:6
r
I
I
1.33
=
LOT 1
Block
64 4CD
(OCCUPIED)
LaM
D.
3.o
s•o -s ci OVERED
c
p
FFE=19.39 I
c
o
LOT
21 o ENTRY
FORMS
°°
w
Cni
O
-
9Q
W o
I
N
Ua
C
CD
I
-------33.0'-------
FORM BOARDS 75
O
TOP OF FORM
o o '
ELEV.=20.80
c
(Susanna II
m
to
330t
o
6' WOODEN
�1
ui;
FENCE (CLEAR)
(tTEEnn'=i1
I I N 90'00'00" E 125.00'
Uj
LOT 2 LOT 22
(OCCUPIED) I o o I (OCCUPIED)
FFE=19.52 I I FFE=20.84
CERTIFICATION
I hereby certify that the survey represented hereon was performed under
my supervision and it complies with the minimum technical standards, as
set forth by the Florida Board of Surveyors & Mappers in Chapter
61G17-6 of the Florida Administrative Code, pursuant to Section 472.027.
Florida Statutes, and further that there ore n " visible above ground
encroachments unless shown or noted.
JULY 7, 2006
Date of Signature WIL A ETT
Professional Surveyor & Mapper
Florida Certificate No., 6353
LB No. 7235
Willa
q
rA " 0" N
I
I s ¢
_N
SI TE
i
g,s;v a
'SIGN
rBYI:
EIVED EEesy Sl 1 iEE�W eI i 1 2 7006 Location Map
1.! c (Not To scale) SCBVN,D Y���
Obt9 L- `OS - St. Lucie Gou
L_ LEGAL DESCRIPTION: flty
p All of LOT 21, BLOCK 64, INDIAN RIVER ESTATES UNIT EIGHT, as recorded
> in Plat Book 10, at Page 73, of the public records of St. Lucie County, Florida.
LOT AREA: 12,991 Sq. Ft.; 0.30 Acres±
O STREET ADDRESS: 5609 Sunset Boulevard, Fort Pierce, Florida.
SURVEYORS' NOTES:
'} 1. Bearings shown hereon are based on the centerline of Sunset Boulevard as
platted and bears SO'00'00"E.
2. Written dimensions take precedence over scaled dimensions and distances are
not to be scaled for construction and/or design purposes.
N 3. All distances and bearings are as field measured and are coincident with "PLAT"
and description data unless otherwise noted.
4. This drawing is not valid without the signature and original raised seal of a
Florida licensed Surveyor & Mapper.
5. This survey is based upon a description furnished by the client, there has been
no search of the public records done by this office.
6. Property lies in Flood Zone "AH17" as scaled from the National Flood Insurance
Program Rate Map, Community Panel Number 12111CO281 F, with an effective date
of August 19, 1991.
7. City water & sewer are not available in this area.
8. Elevations shown hereon are based upon NGVD 1929.
YV.UU I PK
NAIL
EXIST!
WELL I w
I �
LEGEND
= FIRE HYDRANT pd = WATER VALVE
0 = WOOD POWER POLE PUDE= PUBLIC UTILITY &
= TELEPHONE RISER DRAINAGE EASMENT
♦ = WATER METER FIRC = FOUND IRON ROD & CAP
E— POLE ANCHOR X = CABLE TELEVISION RISER
FND = FOUND OHE'= OVERHEAD UTILITY LINES
WPP = WOOD POWER POLE IR = IRON ROD
WM = WATER METER SIRC = SET IRON ROD & CAP
CL = CENTERLINE R/W = RIGHT-OF-WAY
EP = EDGE OF PAVEMENT (P) = PLAT DIMENSION
D = DELTA ANGLE (M) = MEASURED DIMENSION
L = ARC LENTH UE = UTILITY EASEMENT
R = RADIUS ® = DRAINAGE MANHOLE
y p0P= SPOT ELEVATION QS = SANITARY SEWER MANHOLE
CERTIFIED TO: ��
EARL TAYLOR; st. `tatot"
BANK OF AMERICA; U proved
COASTAL LAND TITLE CO. and
LOURAN BUILDERS.
Revised: Added existing well, JS, 12-07-05.
Revised: Changed proposed house plan. JA, 06-08-06.
Revised: Form board tie-in, WBB, 06-19-06.
Revised: Add Porchs (previously not Installed) to form board tie-in, W88, 07-07-06.
Date of Last field work:07/07
Boundary Survey
?e n n e t t Prepared on the order of:
Bennett Surveying + Mapping Louran Builders
439 S.E Port St. Lucie Boulevard Unit 107 Field: LM/dD Job No.: 05-07
Port St. Lucie, Florida 34984
tel: 772.336.4933 fax: 772.336.8689 Drawn: JS Date:09/14/20
email: wbennettddOcs.com Scale: 1"=20' Sheet: 1 of 1
BENCHMARK/ 1
(NGVD 1929)
EL=17so b
SET PK NAIL o
uI ,
FND
1/2' IP
CL
Savanna —Road
(50' Right—of—way), \120' Pavement
N 90'00'00" L 165.00'
±CENTER OF SWALE
N 90'00'00" E
b, 59 0'
C-------------- =-------------------
v'i
CD
W a Block 64
LOT 1 I o LOT 21
0
(OCCUPIED) c
FFE=19.39 c C-ON �J�j n
N a`e��y'
V �l ao
50.0'
--------------------------- --
6' WOODEN (6:
FENCE (CLEAR)
LOT 2 a IL
(OCCUPIED) b b
5
100.00'
,
,
,
,
,
,
in
,
M�
FORM BOARDS
TOP OF FORM
ELEV.=20.80
(Susanna II)
90000'00" E
LOT 22
(OCCUPIED)
FFE=19.52 I I FFE=20.84
CERTIFICATION
I hereby certify that the survey represented hereon was performed under
my supervision and it complies with the 'nimum
technical standards, as
set forth by the Florida Board of Surveyor & Mappers in Chapter
61G17-6 of the Florida Administrative Code, rsuant to Section 472.027,
Florida Statutes, and further that there are n 'bible, ve ground
"
encroachments unless shown or noted.
JUNE 19. 2006
Date of Signature WILLIAM B. E ETT
Pro
JeMmar Surveyor & Mapper
Florida Certificate No. 6353
LB No. 7235
1.3'
IP
0
36.2' I I
w
o�
b
00
I
w
W =
0
- 33.0' - ----- CD
w
C o
rn
1
.>.»
P T I JUN 2 0 2006
b
CMP
-. 3.0-1 w
-------3'---- -
_ U
� o
ma t
ya w
i h� ,b' pb bry
WPP 4'
SIRC i 40.00' -� SET
125.00 PK
EXISTING NAIL
WELL I =
I
LEGEND
= FIRE HYDRANT pd = WATER VALVE
0 = WOOD POWER POLE PUDE= PUBLIC UTILITY &
= TELEPHONE RISER DRAINAGE EASMENT
A = WATER METER FlRC = FOUND IRON ROD & CAP
E—= POLE ANCHOR X ='CABLE TELEVISION RISER
FND = FOUND OHE = OVERHEAD UTILITY LINES
WPP = WOOD POWER POLE IR = IRON ROD
WM = WATER METER SIRC = SET IRON ROD & CAP
CL = CENTERLINE R/W = RIGHT—OF—WAY
EP = EDGE OF PAVEMENT (P) = PLAT DIMENSION
D = DELTA ANGLE (M) = MEASURED DIMENSION
L = ARC LENTH UE = UTILITY EASEMENT
R = RADIUS ® = DRAINAGE MANHOLE
y pop= SPOT ELEVATION OO = SANITARY SEWER MANHOLE
_g.
SI
i fl I
I ! i
Location M8
(Not To Scale)
SCANNEQ
BY
c+ I I IciP county
L_ LEGAL DESCRIPTION:
p All of LOT 21. BLOCK 64, INDIAN RIVER ESTATES UNIT EIGHT, as
> recorded in Plat Book 10, at Page 73, of the public records of St. Lucie
County, Florida.
LOT AREA: 12,991 Sq. Ft.; 0.30 Acres±
STREET ADDRESS: 5609 Sunset Boulevard, Fort Pierce, Florida.
1
SURVEYORS' NOTES:
N 1. Bearings shown hereon are based on the centerline of Sunset Boulevard as
V) platted and bears SO'00'00"E.
2. Written dimensions take precedence over scaled dimensions and distances
are not to be scaled for construction and/or design purposes.
(n 3. All distances and bearings are cis field measured and are coincident
with "PLAT" and description data unless otherwise noted.
4. This drawing is not valid without the signature and original raised seal
of a Florida licensed Surveyor & Mapper.
5. This survey is based upon a description furnished by the client, there
has been no search of the public records done by this office.
6. Property lies in Flood Zone "AH17" as scaled from the National Flood
Insurance Program Rate Map, Community Panel Number 12111CO281 F, with an
effective date of August 19, 1991.
7. City water & sewer are available in this area.
8. Elevations shown hereon are based upon an assumed datum.
CERTIFIED TO:
EARL TAYLOR;
BANK OF AMERICA;
COASTAL LAND TiTLE CO. and
LOURAN BUILDERS.
Revised: Added existing well, JS, 12-07-05.
Revised: Changed proposed house plan, JA, 06-08-06.
Revised: Form board tie—in, WBB, 06-19-06.
Date of Last field work:05/11
Boundary Survey
�e n n ett Prepared on the order of:
Bennett Surveying + Mapping
439 S.E. Port St. Lucie Boulevard Unit 107 Field:
Port St. Lucie, Florida 34984
tel: 772.336.4933 fax: 772.336.8689 Drawn'
email: wbennettdd®cs.com Scale:
Louran Builders
i JD Job No.: Uti—U71
JS Date:09/14/20
=20' 1 Sheet: 1 of 1
EP Savanna Roa -
0
Right—of—way) 20' Pave
i
N 90'00'00"
BE E'er 100.00'
! 3e
(NGVD 1929) SEP
EL-17.50 0—
SET PK NAIL
w+_ *CENTER OF SWALE
N 90'00'00" E 100.00'
wz• IP
O
O
Uj----- -------59_R--------------
0
LOT 1 W I Block 64
(OCCUPIED) c o_
FFE=19.39 0 o LOT 21
CONCRETE
STOOP r
50.0'
------------------------
6' WOODEN ly EXISTNG WELL
FENCE (CLEAR)
WU
Wp
riNO
Krcw
ONE—STORY
RESIDENCE
FFE=20.80
n ai (Susanna II)
42.0'
A/C
"NO I N 90000'00" E
LOT 2 a I LOT 22
(OCCUPIED) o o (OCCUPIED)
FFE=19.52 I FFE=20.84
CERTIFICATION
I hereby certify that the survey represented hereon. was performed under
my supervision and it complies with the minimur 4.echnieal standards, as
set forth by the Florida Board of Surveyors B;;.Mappc s in!ghapter
61G17-6 of the Florida Administrative C pu:'I orit'to,'Se Lien 472.027,
Florida Statutes, and further that there arej, o421 ' e, above ground
encroachments unless shown or noted. 1,
JANUARY 22, 2007
Date of Signature
1
)r &'Mapper
No. 6353
125.009
65e— DDT
w
x
C
— -
- L o -
1
oo,
0 0 =
p C
" 1 140.00'
x
----------------------
36.2'
SANITARY
CLEANOUT O o
O
o '
ao w
_ Wa
])ia,5111
WC----- 33.0' ------ ' O^ I w
18"x24" I CMP
m
16' CONCRETE
Q
DRIVEWAY
O
'(
N
33.0'
C
�
w
¢a
�i
w
".�" --
_
� w
--•
h�
A-
'nNG
EXISWELL I w
,I
a
LEGEND
=
TELEPHONE RISER
01 =
WOOD POWER POLE
♦ =
WATER METER
D4 =
WATER VALVE
i—=
POLE ANCHOR
PUDE=
PUBLIC UTILITY &
FND =
FOUND
,
DRAINAGE EASMENT
WPP =
WOOD POWER POLE
FIRC =
FOUND IRON ROD & CAP
WM =
WATER METER
X =
CABLE TELEVISION RISER-
CL =
CENTERLINE
OHE =
OVERHEAD UTILITY LINES
EP =
EDGE OF PAVEMENT
SIRC =
SET IRON ROD & CAP
00!3=
SPOT ELEVATION
UE' =
UTILITY EASEMENT
Z
c
c
a
C
m
E
C
a
O
N
- I ! E Iesy1 s11 I
Location Map
(Not To Scale)
LEGAL DESCRIPTION:
All of LOT 21, BLOCK 64, INDIAN RIVER ESTATES UNIT EIGHT, as
L recorded in Plat Book 10, at Page 73, of the public records of St. Lucie
Q County, Florida.
mLOT AREA: 12,991 Sq. Ft.; 0.30 Acres±
=O STREET 'ADDRESS: 5609 Sunset Boulevard, Fort Pierce, Florida.
SURVEYORS' NOTES:
`} 1. Bearings shown hereon are based on the centerline of Sunset Boulevard as
platted and bears SO'00'00"E.
2. Written dimensions take precedence over scaled dimensions and distances
C are not to be scaled for construction and/or design purposes.
3. All distances and bearings are as field measuredand are coincident with
"PLAT" and description data unless otherwise noted. 3
W 4. This drawing is not valid without the signature and original raised seal of a
Florida licensed Surveyor & Mapper.
5. This survey is based upon a description furnished by the client, there has
been no search of the public records done by this office.
6. Property lies In Flood Zone "AH17" as scaled from the National Flood
Insurance Program Rate Map, Community Panel Number 12111CO281 F, with an
effective date of August 19. 1991.
7. City water & sewer are not available in this area.,
8. Elevations shown hereon are based upon NGVD 1929.
CERTIFIED TO:
EARL TAYLOR; SCANNED
NAIL BANK OF AMERICA;' BY
COASTAL LAND TiTLE and St. Lucie County
LOURAN BUILDERS, INC.
Revised: Added existing well, JS, 12-07-05.
Revised: Changed proposed house plan, JA, 06-08-06.
Revised: Forth board tie—in. WBB, 06-19-06.
Revised: Add Porchs (previously not Installed) to form board tie—in. WBB, 07-07-06.
Revised: Final tie—in, WBB; 01-21-07.
Date of Last field work:01/22/2007
.I Final. Tie —In Survey
... e n n e t t Prepared on fhe order of:
Bennett Surveying + Mapping Louran Builders, Inc.
439 S.E. Port St. Lucie Boulevard Unit 107 Field: LM/JD Job No.: 05-0703
Port St. Lucie, Florida 34984
tel: 772.336.4933 fax: 772.336.8689 Drawn, JS Date: 09/14 2005
email: wbennettdd®cs.com I Scale: 1"=20' 1 Sheaf: 1 of 1 ;