Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEV V FORM 60OA-2001 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING -CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: Rodriques residence Builder: owner Address: Lot: 5, Sub:, indian rvr esta, Plat: block 66 unit 8 Permitting Office: City, 'State: Ft Pierce, FL Permit Number. Owner: Jurisdiction Number: Climate Zone: Central 1. New construction or existing New - 12. Cooling systems 2. Single family or multi -family Single family _ a. Central Unit S Cap: 34:0 kBtu/bT _ 3. Number of units, if multi -family 1 _ CANNED SEER: 10.00 - 4. Number of Bedrooms 3 - b. N/A �t By - 5. Is this a worst case? No _ Lucie co Un•fiY 6. Conditioned floor area (ft') 1299 ft' c. N/A - 7. Glass area & type Single Pane Double Pane - - a. Clear glass, default U-factor 0.0 ft' 0.0 ft' - 13. Heating systems b. Default tint 198.7 ft' 0.0 ft' - a. Electric Heat Pump Cap: 24.8 kBtu/hr _ c. Labeled U or SHGC 0.0 ft' 0.0 ft' HSPF: 7.00 _ 8. Floor types - b. N/A - a. Slab -On -Grade Edge Insulation R=0.0, 174.0(p) It - - b. N/A - 6. N/A - c. N/A - 9. - Wall types - 14. Hot water systems a. Concrete, Ext Insul, Exterior R=4.0, 1059.7 ft' - a. Electric Resistance Cap: 50.0 gallons _ b. �rame, Wood, Adjacent R=11.0, 152.2 ft' c. N/A _ - b. N/A FILE d. N/A _ e. N/A c. Conservation credits 10. Ceiling types _ (HR-Heat recovery, Solar a. Under Attic R=19.0, 1298.9 ft' _ DHP-Dedicated heat pump) b, N/A _ 15. HVAC credits CF, _ c. N/A (CF-Ceiling fan, CV -Cross ventilation, I1. - Ducts _ HF-Whole house fan, a. Sup: Unc. Ret: Con. AH: Interior Sup. R=6.0, 125.0 ft - PT -Programmable Thermostat, b. �I/A - MZC-Multizone cooling, W-H-Multizone heating) Glass/Floor Area: 0.15 Total as -built points: 19963 PASS Total base points: 20620 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: L DATE: 9'-v[o �DS I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. /A A DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: Fnarnvr:ai,ncfkl !t/arry ion: FLRCSB v3.30) FORM 60OA-2001 r - Code Compliance Checklist Residential Whole Building Performance Method A - Details I ADDRESS: Lot: 5, Sub: Indian,rvr esta, Plat: block 66 unit 6, Ft Pierce, FL, PERMIT #: I INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cttrr/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1 ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill. plate; jointsbetween exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous Infiltration barrier is installed that extends from and is,sealed to, the foundation to the top plate. Floo 606.1 ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss orjoint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor, around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier, gaps In gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed thatis sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated,with no penetrations, sealed; or Type IC or non -IC rated, installedinsidea sealed box with 1/2" clearances& 3" from insulations or Type IC rated with < 2.0 cfm from ditied space, tested. Multi-sto Houses 606.1.ABC.1.2:5 An perimeter of floor cavity between floors. Addi,ional Infiltration reqts 606.1ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. se 09 nT41F0 PAFSCRIPTIVF MFARI IRFR !moist ha mat nr awrandpd by all rncidnnces_1 COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers(except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air istribution Systems 610.1 All ducts, fittings,,mechanical equipment and plenum chambers shall, be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3both sides. Common ceiling & floors R-11. EnergyGaugeTM DCA Form 60OA-2001 EnergyGauge®/FIaRES'2001 FLRCSB v3.30 j: T: <j- ,, I .� I � .. , T " - , , C. . .. FORM 60OA-2001 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: Lot: 5, Sub: Indian rvr esta, Plat: block 66 unit 8, Ft Pierce, FL, PERMIT #: BASE WATER HEATING Number of X Multiplier Total _ 1 3 2664.00 7692.0 AS -BUILT Tank EF Number of X Tank X Multiplier X Credit = Total Volume Bedrooms Ratio Multiplier 60.0 0.97 3 1.00 2326.10 1.00 6978.3 As -Built Total: 6978.3 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling Points + Heating + Points Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total Points Points Points 10315 2613 7692 20620 9003 3981 6978 19963 PASS EnergyGaugeTM DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCSB v3.30 r A l t L., y i r ... n r n .. :. a, r . AWN, .. .,, .. A :r i FORM 6p0A-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: 5, Sub: Indian rvr esta, Plat: block 66 unit 8, Ft Pierce, FL, PERMIT #: I BASE AS -BUILT INFILTRATION Area X BWPM = Points Area X WPM = Points 1299.0 -0.28 -363.7 1299.0 -0.28 -363.7 Winter Base Points: 4164.5 Winter As -Built Points: 7164.5 Total Winter X ,Points System Multiplier = Heating Points Total X Component Cap Ratio X Duct X System X Multiplier Multiplier (DM x DSM x AHU) Credit = Multiplier Heating Points 4164.6 0.6274 ' 2612.8 7164.5 7164.5 1.000 1.00 (1.068 x 1.160 x 0.92) 0.488 1.140 0.488 1.000 1.000 3981.4 3981.4 Ene,rgyGauge' DCA Form 60OA-2001 EnergyGauge®/FIaRES'2001 FLRCSB v3.30 4 i FORM FOOA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: Lot: 6, Sub: Indian rvr esta, Plat: block 66 unit 8, Ft Pierce, FL, PERMIT #: I BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point .18 1299.0 5.86 1370.2 Single, Tint E 1.5 4.5 12.0 13.04 1.03 161.1 Single, Tint N. 1.5 3.5 6.0 15.38 0.99 91.8 Single, Tint W 1.5 5.5 22.5 13.80 1.01 314.4 Single, Tint E 9:0 8.5 48.0 13.04 1.17 734.7 Single, Tint- W 2.0 10.2 6.7 13.80 1.01 92.9 Single, Tint NE 2.5 5.5 16.0 15.07 1.00 226.3 Single, Tint E 1.5 5.5 15.0 13.04 1.02 199.5 'Single, Tint SE 1.5 5.5 15.0 11.49 1.06 182.2 Single, Tint W 1.5 5.5 22.5 13.80 1.01 314.4 Single, Tint S 1.6 4.5 12.0 10.88 1.11 145.4 Single, Tint S 1.5 4.5 12.0 10.88 1.1.1 145.4 I' Single; Tint S 1.5 4.5 12.0 10.88 1.11 145.4 As -Built Total: 198.7 2753.6 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM, = Points Adjacent 152.2 1.80 274.0 Concrete, Ext Insul, Exterior 4.0 1059.7 2.40 2543.3 Exte or 1059.7 2.00 2119.4 Frame, Wood, Adjacent 11.0 152.2 1.80 274.0 Base�Total: 1211.9 2393.4 As -Built Total: 1211.9 2817.2 DOOR TYPES Area X BWPM = Points Type Area X WPM' = Points Adjacent 17.8 4.00 71.2 Exterior Wood 37.8 7.60 287.3 Exte for 37.8 5.10 192.8 Adjacent Wood 17.8 5.90 105.0 BaseaTotal: 65.6 264.0 As -Built Total: 55.6 392.3 CEI LI ING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Unde'rAttic 1298.9 0.64 831.3 Under Attic 19.0 1298.9 0.87X 1.00 1136.0 Base; Total: 1298.9 831.3 As -Built Total: 1298.9 • 1130.0 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 174.0(p) -1.9 -330.6 Slab -On -Grade Edge Insulation 0.0 174.0(p 2.50 435.0 Raised 0.0 0.00 0.0 Base,Total; -330.6 As -Built Total: 174.0 435.0 EneigyGauge® DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCSB v3.30 °t, .,`illV ^�ii j?ti �ru � �. n " ..� I� � .`'� 1 � . � F t 1 .r� i�`, r.,aer�r'ri.�;.„1�"a i 'f'!a �it� j`8' �a.�,"?.;��', .. .<: _. ..,. .?.G�: l .. rn ..� .. .. . , lid +a..F'. .. _.. .. ,1._,. �� ... .. .4a. .. .. _.. .: i ' .. .. .... .. ..... .... ,.. .�. ..... .. .,.- n _ _..... , . !' . Z• _ n, s'v a � � ;. i � ;.. r. .. ,. � �. Y.. � .. �. �� ' � .. ;a� � ,� i ,. _ i � � . � ., r. a. k �� .� .� ... .. <... � � i i .. .. ... .. .. l n... n.... � y a ... ... I r.: e ..1. '.� L { _ i � ti a 1. FORM 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: 5, Sub: indian rvr esta, Plat: block 66 unit 8, Ft Pierce, FL, PERMIT #: I BASE AS -BUILT INFILTRATION Area X BSPM = Points Area X SPM = Points 1299.0 14.31 18588.7 1299.0 14.31 18588.7 Summer Base Points: 24179.9 Summer As -Built Points: 24886.2 Total Summer Points X System = Multiplier Coaling Points Total X Component Cap Ratio X Duct X System X Multiplier Multiplier (DM x DSM x AHU) Credit Multiplier = Cooling Points 24179.9 0.4266 10316.2 24885.2 24885.2 1.000 1.00 (1.079 x 1.150 x 0.90) 0.341 1.117 0.341 0.950 0.950 9002.9 9002.9 EnergyGauge" DCA Form 60OA-2001 EnergyGauge0/FIaRES'2001 FLRCSB v3.30 I I FORM 6.00A-2001 1 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: Lot: 5, Sub: Indian rvr esta, Plat: block 66 unit 8, Ft Pierce, FL, PERMIT #: I BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang. Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 1299.0 25.78 6027.9 Single, Tint E 1.5 4.5 12.0 53.27 0.86 548.1 Single, Tint N 1-.5 3.5 6.0 24.46 0.86 126.7 Single, Tint W 1.5 5.5 22.5 47.90 0.90 971.7 Single, Tint E 9.0. 8.5 48.0 53.27 0.51 1316.2 Single, Tint W 2.0 10.2 6.7 47.90 0.95 304.8 Single, Tint NE 2.5 5.5 15.0 38.88 0.79 460.6 Single, Tint E 1.5 5.5, 15.0' 53.27 0.90 721A Single, Tint SE 1.5 5.5 15.13 50.80 0.87 663.5 Single, Tint ' W 1.5 5.5 22.5 47.90 0.90 971.7 Single, Tint S 1.5 4.5 12.0 39.84 0.80 382.8 Single, Tint S 1.5 4.5 12.0 39.84 0.80 382.8 Single, Tint S 1.5 4.5 12.0 39.84 0.80 382.8 As -Built Total: 198.7 7233.0 WALI L TYPES Area X BSPM = .Points Type R-Value Area X SPM = Points Adjacent 152.2 0.70 106.5 Concrete, Ext Insul, Exterior 4.0 1059.7 0.60 529.8 Extenor 1059.7 1.90 2013.4 Frame, Wood, Adjacent 11.0 152.2 0.70 106.5 BaseiTotal: 1211.9 2120.0 As -Built Total: 1211.9 636.4 DOOR 1 TYPES Area X BSPM = Points Type Area X SPM Points Adjacent 17.8 1.60 28.5 Exterior Wood 37.8 7.20 272.2 Exterior 37.8 4.80 181.4 Adjacent Wood 17.8 2.40 42.7 BaselTotal: 55.6 209.9 As -Built Total: 65.6 314.9 CEILING TYPES Area X BSPM = Paints Type R-Value Area X SPM X SCM = Points UnderAttic 1298.9 2.13 2766.7 Under Attic 19.0 1298.9 2.82X 1.01) 3662.9 Base, Total: 1298.9 2766.7 As -Built Total: 1298.9 3662.9 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 174.0(p) -31.8 -5533:2 Slab -On -Grade Edge Insulation 0.0 174.0(p -31.90 -5550.6 Raised 0.0 0.00 0.0 (Total: 174.0 Bas -5533.2 As -Built Total: -5550.6 EnergyGauge® DCA Form 60OA-2001 EnergyGauge4D/FlaRES'2001 FLRCSB v3.30 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 83.7 The higher the score, the more efficient the home. , Lot: 5, Sub: indian rvr esta, Plat: block 66 unit 8, Ft Pierce, FL, 1. New construction or existing 2. Single family or multi -family 3. Number of units, if multi -family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Glass area & type a. Clear - single pane b. Clear - double pane c. Tint/other SHGC - single pane d. Tint/other SHGC - double pane 8. Floor types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 9. Wall types a. Concrete, Ext Insul, Exterior b. Frame, Wood, Adjacent c. N/A d. N/A e. N/A 10: Ceiling types a. Under Attic b. N/A e. N/A I1. ucts a. up: Unc. Ret: Con. AH: Interior b. /A New - 12. Cooling systems Single family - a. Central Unit Cap: 34.0 kBtu/hr 1 _ SEER:10.00 3 _ b. N/A No _ - 1299 112 c. N/A - Single Pane Double Pane _ - 0.0 ft2 0.0 ft2 - 13. Heating systems 198.7 ft2 0.0 ft2 - a. Electric Heat Pump Cap: 24.8 kBtu/hr _ 0.0 ft2 0.0 ft2 _ FILEHSPF: 700=b. N/A OPT- 14. R=0.0, 174.0(p) It c. N/A Hot water systems a. Electric Resistance Cap: 50.0 gallons - R=4.0, 1059.7 ft2 _ EF: 0.97 R=11.0, 152.2 ft2 _ b. N/A - _ c. Conservation credits _ (HR-Heat recovery, Solar _ DHP-Dedicated heat pump) R=19.0, 1298.9 ft2 _ 15. HVAC credits . CF, _ (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, _ PT -Programmable Thermostat, Sup. R=6.0, 125.0 ft - MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Address of New Home: City/FL Zip: • 'NOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. Ifyour score is 80 or greater (or 86 for a US EPADOE EnergyStar""designation), your home may qualifyfor energy efficiency mortgage (EE4 incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec. ucf. edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affatr9tWgy6*WUWprsion: FLRCSB v3.30) r r r I t: Rodriquef Residence HVAC Load Calculations for Prepared By: Shawn Mock S & S A\C & Refrigeration Port St. Lude, FL 34953 (772) 336.9846 Thursday, September 15, 2005 F 1 Title: ad By: Date: Comment: Comment: any Name: any Representative: any City: any Phone: any Fax: any Comment: Rodriquez Residence Shawn Mock 9-15-05 Edit the file AUTOLOAD.RHV so that it contains your company name, weather data, and any other information you would like to have in each new project that you start. S & S MC & Refrigeration Shawn Mock Port St. Lurie, FL. 34953 (772)336-9646 (772) 336-8169 Daily Temperature Range: Latitude Elevation: Altitude Fedor. Elevation Sensible Adj. Factor: Elevation Total Adj. Factor. Elevation Heating Adj. Factor. Elevation Heating Adj. Factor: Winter. summer. Medium 27 Degrees 25 ft. 0.999 1.000 1.000 1.000 1.000 Outdoor Outdoor Dry But Wet BUI 45 0 90 '18 ft. of Room Area: 1,299 (ft) of Cond. Space: 12,528 Indoor Indoor Groins Rei.Hum Dry But D'rfference 0 72 0 50 75 61 Square ft. Per Ton: 494 Air Turnover Rate (per hour): 5.7 Total Sensible Gain: 24,298 Stuh 85 % Totai Latent Gain: 4,455 Stuh 15 % Total ;Cooling Required With Outside Air: 28,753 Btuh 2.40 Tons (Based On Sensible + Latent) 2.63 Torts (Based On 77% Sensible Capacity) C.aicuiations are based on am etlmon or ALGA manusi J. All computed results are estimates as building use and weather may vary. Be sure to select a and that meets both sensible and latent bads. C:1EIdelRhvacwlProjectslardic breeze rodriquez.rhv Thursday, September 15, 2005, 7:06 PM •'S custemlA-ibo: Glazing-operabie window low a metal frame w break single hung customlA-tb-d: Glazing -eliding glass door single pane low e glass metal frame door w break customlB-ib: Glazing -foxed window low a metal frame w break 111: Door -Panel With Metal Storm { 11 D: Door -Solid Core 13A-4ocs: Well -Block, board insulation only, R-4 board inn$�I ulation, open core, siding finish 12B Osw: Wall -Frame, R-11 insulation in 2 x 4 stud cavity, no, board insulation, siding finish, wood studs 168-19: Roof/Ceiling-Under attic or knee wall, Vented Attic, No Radiant Barrier, Deck Asphalt Shingles or Dark Metal, Ter and Gravel or Membrane, R-19 insulation 22A-ph: Floor -Slab on grade, No edge insulation, no insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: People: Equipment: Lighting: Ductwork: Infiltration: Winter CFM: 157, Summer CFM: 73 Ventilation: Winter CFM: 0, Summer CFM: 0 Total (Building Load Totals: ft. of Room Area: 1,299 (W) of Cond. Space: 12,528 48 1,413 0 1,861 1,861 i 45 1.323 0 2,947 2,947 37.8 367 0 354 354 17.8 104 0 104 104 1059.7 4,094 0 2,317 2,317 152.2 221 0 221 221 I I 1298.9 1,717 0 3,182 3,182 174 6,380 0 0 0 18,728 0 17,340 17,340 i 4 920 1,200 2,120 500 1,200 1,700 0 0 0 817 0 3,351 3,361 4,646 3,035 1,207 4,242 0 0 0 0 24.191 4,455 24,298 28,753 wrmr2 I 0.924 Square ft. Per Ton: 494 Air Turnover Rate (per hour): 5.7 w� Total Sensible Gain: 24,298 Stuh 85 % Total Latent Gain: 4,455 Btuh 15 % Total Cooling Required With Outside Air: 28,753 Btuh 2.40 Tons (Based On Sensible + Latent) 2.63 Tons (Based On 77% Sensible Capacity) Calculations are based on 8th edition of ACCA Manuel I All computed results are estimates as building use and weather may very. Be sure to select a unit that meets both sensible and latent loads. C:\Elite\RhvacwiPro)ects\arctic breeze roddquez.rhv Thursday, September 15, 2005, 7:06 PM Loads GUetomlA-th-o: UNOngOperaDle wlnoow row a metal frame w break single hung customlA-fb.d: Glazing -sliding glass door single pane low e glass metal frame door w break custom'! Bob: Glazing -fixed window low a metal frame w break 111. Door -Panel With Metal Storm 11D: Door -Solid Core 113A-4oc:s: Wall -Block, board Insulation only, R-t board insulation, open core, siding finish f 1284Osw: Wail -Frame, R-11 insulation in 2 x 4 stud cavity, no board insulation, aiding finish, wood studs 116E-ig: Roof/Ceiling-Under attic or knee wall, Vented Attic, No Radiant Barrier, Dads Asphalt Shingles or I Dark Metal, Ter and Gravel or Membrane, R-19 insulation 22A-ph: Flw-Slab on grade, No edge insulation, no insulation below floor, any floor cover, passive, heavy moist soil I Subtotals for structure: People: Equipment: Lighting: Ductwork: Infiltration: Winter CFM: 157, Summer CFM: 73 j Ventilation: Winter CFM: 0, Summer CFM: 0 System 1 Load Totals: Total Total l Total I ft. of Room Area: 1,299 (n of Cond. Space: 12,528 48 1,413 0 1,861 1,861 45 1,323 0 2,947 2,947 37.8 367 0 354 354 17.8 104 0 104 104 1059.7 4,094 0 2,317 2,317 152.2 221 0 221 221 1298.9 1,717 0 3,182 3,182 174 6,380 0 0 0 4 0 18,726 0 17,340 17,340 920 1,200 2,120 500 1,200 1,700 0 0 817 0 3,351 3,351 4,646 3,035 1,207 4,242 0 0 0 0 24,191 4,455 24,298 28,753 Square ft. Per Ton: 494 Air Turnover Rate (per hour): 5.7 Is Gain: 24.298 Bluh 85 % Gain: 4,455 Btuh 15 % 3 Required With Outside Air: 28.753 Btuh 2.40 Tons (Based On Sensible + Latent) 2.63 Tons (Based On 77% Sensible Capacity) All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. I C:1ElitelRhvecw%Pro}eetslarctic breeze rodriquez.rhv I i i i i Thursday, September 15, 2005, 7:06 PM —Lulle I— I Bedroom 1 2 Bath 1 3 Bedroom 2 4 Living Room 5 Foyer 6 Breakfast Area 7 kAchen 8 Dining Room 9 Master Bath 10 Wic 11 Master Bedroom 12 Laundry System 1 total System 1 Main Trunk Sire: Velocity: Loss oer 100 ft.: Type:' Model; Brand: Efficiency: sound: Capacity: Sere is Capacity: Latent Capacity: I ..SQ 156 3,046 151 47 802 40 156 3,524 175 212 2,957 147 62 1,060 53 72 3,253 161 132 219 11 117 2,253 112 90 2,345 116 25 613 30 184 3,346 166 46 773 38 1,299 24,191 1,200 15x15 in. 859 ft./min 0.090 in.wg 16 560 2,227 445 1-3 511 508 100 2-5 587 3,243 481 2-6 472 3,750 706 1-4 674 1,191 117 2.6 514 4,087 343 15 532 2,115 230 2-5 501 2,768 264 15 489 1,360 317 1-2 541 239 100 1-6 521 2,071 481 1-4 424 749 871 24,298 4,455 '110 110 25 25 160 160 185 185 59 59 202 202 104 104 137 137 67 67 12 12 102 102 37 37 1,200 1,200 3 '« 1 fq v Wi 9,200 34,000 i iz N x i t ,.. ,,, d/ �.:.«ict y v gyr�,, y r� x Aa tl'{,LpltGx'u.1e:J,Yi.rad�Fr'i'ti't�a*at y �'i pti i,t CONDENSOR DO Rheem Rheem 0 :00 Btuh 00 Btuh i _._.__.___.—....___.____._....... ..._._._......__........_____.__.__.___..___ Q%Elit®�Rhvacw%Projectslarctic breeze rodriquez.rhv Thursday, September 15, 2005, 7:06 PM