HomeMy WebLinkAboutENERGY EFFICIENCY CODERECETVEII JAN 0 9 2019
FORM R405-2017 DEC id!)1g F CY
FLORIDA
ENGY.EFFICIENC�( CO C NSTRUCTION
Luae COUr1tq, Pe7mittinn
Florida Departmen o ssaTld-Professional Regulation - Residential Performance Method
'Project Name: FRAN BISHOP
Builder Name: BISHOP HOMES, LLC.
SCANNED
Street: 3608 GROVE COURT
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
BY
Owner:
Jurisdiction: ST LUCIE COUNTY
St. County
Design Location: FL, Fort Pierce
I
�ucie
County: Indian River (Florida Climate Zone 2
1. New construction or existing
New (From Plans)
9. Wall Types It 876.0 sqft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block- Ext Insul, anterior
R=4.1 1661.30 ft'
b. Frame - Wood, Adjacent
R=11.0 214.67 ft'
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
2
d. N/A
R= ft2
5. Is this a worst case?
No
10. Ceiling Types (1890.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 1890.00 ft2
6. Conditioned floor area above grade (ft2)
1890
b. N/A
R= ft2
Conditioned floor area below grade (1112)
0
c. N/A
R= ft2
11. Ducts
R 1112
7. Windows(230.0 sqft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: AHU CLST
6 150
a. U-Factor: Sgl, U=0.65
230.00 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A
ft2
12. Coding systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
35.0 SEER:16.00
c. U-Factor: N/A
ft2
SHGC:
-
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A
ft2
a. Electric Strip Heat
27.0 COPA.00
SHGC:
Area Weighted Average Overhang Depth:
2.000 ft.
Area Weighted Average SHGC:
0.250
14. Hot water systems
a. Electric.
Cap: 50 gallons
8. Floor Types (1890.0 sgft.)
Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation
R=0.0 1890.00 ft2
b. Conservation features '
b. N/A
R= ft2
None
c. N/A
R= ft2
15. Credits
None
Glass/Floor Area: 0.122
Total Proposed Modified Loads: 57.85
PASS
Total Baseline
Loads: 61.89
1 hereby certify that the plans and specifications covered by
Review of the plans and
IT STg7,
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
y p„ ' ,•• o
with the Florida Energy Code.
PREPAR
BZPBefore
construction is completed
DATE: -
this building will be inspected for
compliance with Section 553.908
n�
I hereby certify that this b ' di , as desig is omph ce
Florida Statutes.
with the Florida Energy
COp WE
OWNER/AGFig
BUILDING OFFICIAL:
DATE:
DATE:
Compliance requires certification by th air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance it
R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
8/29/2018 11:24 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
FRAN BISHOP
Bedrooms: 2
Address Type:
Street Address
Building Type:
User
Conditioned Area: 1890
Lot#
Owner Name:
Total Stories: 1
BlocMSubdiAsion:
#of Units:
1
Worst Case: No
PlatBook:
Builder Name:
BISHOP HOMES, LLC.
Rotate Angle: 0
Street:
3608 GROVE COURT
Permit Office:
ST LUCIE COUNTY
Cross Ventilation: No
County:
Indian River
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FORT PIERCE,
Famil�Type:
Single-family
FL,
New/ xisting:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
1890
17766
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1
MASTER BEDROO
299
2810.6 No
0
1
1
Yes
Yes °
Yes
2
M WIC
72
676.8 No
0
1
Yes
Yes
Yes
3
M BATH
152
1428.8 No
0
1
Yes
Yes
Yes
4
WIC 2
48
451.2 No
0
1
Yes
Yes
Yes
5
BEDROOM 2
180
1692 No
0
1
1
Yes
Yes
Yes
6
M TOILET
18
169.2 No
0
1
No
Yes
Yes
7
BATH 2
56
526.4 No
0
1
No
Yes
Yes
8
LAUNDRY
70
658 No
0
1
No
Yes
Yes
9
AHU CLST
20
188 No
0
1
Yes
Yes
Yes
10
STUDY
180
1692 No
0
1
Yes
Yes
Yes
11
HALL
72
676.8 No
0
1
No
Yes
Yes
12
STUDYCLST
6
56.4 No
0
1
No
Yes
Yes
13
LINEN
21
197.4 No
0
1
No
Yes
Yes
14
KITCHEN
241
2265.4 Yes
0
1
Yes
Yes
Yes
15
GREAT ROOM
273
2566.2 No
0
1
Yes
Yes
Yes
16
DINING
182
1710.8 No
0
1
Yes
Yes
Yes
FLOORS
#
Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation
MASTER
BEDRO 43 it 0
299 fF
___
1 0
0
2 Slab -On -Grade Edge Insulation
M W IC 9 ft 0
72 ft'
___
1 0
0
8/29/2018 11:24 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 2 of 6
FORM R406-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
3 Slab -On -Grade Edge Insulation
M BATH
16 ft
0
152 ft2
____
1
0
0
4 Slab -On -Grade Edge Insulation
WIC 2
6 ft
0
48 ft2
1
0
0
5 Slab -On -Grade Edge Insulation
BEDROOM 2
14 ft
0
180 ft2
____
1
0
0
6 Slab -On -Grade Edge Insulation
M TOILET
1 ft
0
18 ft'
____
1
0
0
7 Slab -On -Grade Edge Insulation
BATH 2
1 ft
0
56 ft2
___
1
0
0
8 Slab -On -Grade Edge Insulation
LAUNDRY
1 ft
0
70 ft2
___
1
0
0
9 Slab -On -Grade Edge Insulation
AHU CLST
4 ft
0
20 ft2
___
1
0
0
10SIab-On-Grade Edge Insulation
STUDY
22 ft
0
180 ft2
1
0
0
11SIab-On-Grade Edge Insulation
HALL
1 ft
0
72 ft2
___
1
0
0
12SIab-On-Grade Edge Insulation
STUDY CLST
1 ft
0
6 ft2
___
1
0
0
13SIab-On-Grade Edge Insulation
LINEN
1 ft
0
21 ft2
__
1
0
0
14SIab-On-Grade Edge Insulation
KITCHEN
25 ft
0
241 ft2
---
1
0
0
15SIab-On-Grade Edge Insulation
GREAT ROOM
11.9 ft
0
273 ft2
___
1
0
0
16SIab-On-Grade Edge Insulation
DINING
27ft
0
182 ft2
____
1
0
0
ROOF
Roof
Gable
Roof
Solar
SA Emitt
Emitt
Deck
Pitch
V
# Type Materials
Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Hip
Metal 2114 ft'
0 ft'
Light
0.6
No 0.9
No
20
26.6
ATTIC
/
V
# Type
Ventilation
Vent Ratio (1
in)
Area
RBS IRCC
1 Full attic
Unvented
0
1890 ft2
N N
8/29/2018 11:24 AM EnergyGaugeO USA Section R405A.1 Compliant Software Page 3 of 6
FORM R406-2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Fmc Truss Type
_
1
Under Attic (Unvented) MASTER BEDRO
20
Blown
299 fP
0.1
Wood
_
2
Under Attic (Unvented) MWIC
20
Blown
72 ft-
0.1
Wood
_
3
Under Attic (Unvented) M BATH
20
Blown
152 ft2
0.1
Wood
4
Under Attic (Unvented) WIC
20
Blown
48 ft2
0.1
Wood
5
Under Attic (Unvented) BEDROOM
20
Blown
180 ft2
0.1
Wood
6
Under Attic (Unvented) MTOILET
20
Blown
18 ft2
0.1
Wood
7
Under Attic (Unvented) BATH
20
Blown
56 ft2
0.1
Wood
8
Under Attic (Unvented) LAUNDRY
20
Blown
70 ft2
0.1
Wood
_
9
Under Attic (Unvented) AHU CLST
20
Blown
20 ft-
0.1
Wood
_
10
Under Attic (Unvented) STUDY
20
Blown
180 ft'
0.1
Wood
11
Under Attic(Unvented) HALL
20
Blown
72 ft2
0.1
Wood
_
12
Under Attic (Unvented) STUDYCLST
20
Blown
6W
0.1
Wood
13
Under Attic (Unvented) LINEN
20
Blown
21 ft2
0.1
Wood
_
14
Under Attic (Unvented) KITCHEN
20
Blown
241 ft'
0.1
Wood
_
15
Under Attic(Unvented) GREAT ROOM
20
Blown
273 ft2
0.1
Wood
16
Under Attic (Unvented) DINING
20
Blown
182 ft2
0.1
Wood
WALLS
Adjacent
Cavity
Width Height
Sheathing Framing
Solar Below
Space
_ 1
E
Exterior Concrete Block - Ext Insd19ASTER BE
4.1
17
0 9
4
158.7 ft.
0
0
0.6
0
_ 2
W
Exterior Concrete Block - Ext InsLWASTER BE
4.1
12
0 9
4
112.0 ft-
0
0
0.6
0
_ 3
N
Exterior Concrete Block - Ext InsJNASTER BE
4.1
14
0 9
4
130.7 ft2
0
0
0.6
0
4
E
Exterior Concrete Block - Ext Insul M W IC
4.1
9
0 9
4
84.0 ft2
0
0
0.6
0
_ 5
E
Exterior Concrete Block- Ext Insul M BATH
4A
16
0 9
4
149.3 ft'
0
0
0.6
0
6
E
Exterior Concrete Block- Ext Insul WIC 2
4.1
6
0 9
4
56.0 ft2
0
0
0.6
0
_ 7
E
Exterior Concrete Block- Ext Insd6EDROOM 2
4.1
14
0 9
4
130.7 ft2
0
0
0.6
0
_ 8
W
Exterior Concrete Block - Ext InsuIAHU CLST
4.1
4
0 9
4
37.3 ft2
0
0
0.6
0
_ 9
S
Exterior Concrete Block- Ext Insul STUDY
4.1
7
0 9
4
65.3 ft2
0
0
0.6
0
_ 10
W
Exterior Concrete Block- Ext Insul STUDY
4.1
15
0 9
4
140.0 ft2
0
0
0.6
0
_ 11
S
Exterior Concrete Block- Ext Insul KITCHEN
4.1
8
0 9
4
74.7 ft2
0
0
0.6
0
_ 12
W
Exterior Concrete Block - Ext Insul KITCHEN
4.1
17
0 9
4
158.7 ft2
0
0
0.6
0
_ 13
N
Exterior Concrete Block - Ext InsaREAT ROO
4.1
12
0 9
4
112.0 ft2
0
0
0.6
0
_ 14
W
Exterior Concrete Block - Ext Insul DINING
4.1
14
0 9
4
130.7 ft2
0
0
0.6
0
15
N
Exterior Concrete Block-Ext Insul DINING
4.1
13
0 9
4
121.3 ft2
0
0
0.6
0
16
S
Garage Frame -Wood LAUNDRY
11
23
9
4
214.7 ft2
0
0.25
0.600000
0
DOORS
#
Orm Door Type Space
Storms
U-Value
Width
Height Area
Ft
In
Ft
In
1
S Insulated KITCHEN
None
.39
3
8
24 ft2
8/29/2018 11:24 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 6
FnRne RADF-9n17 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
V #
Wall
Ornt ID Frame
Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation
Int Shade
Screening
1
_ 2
_ 3
_ 4
5
_ 6
7
_ 8
9
W 2 Metal
N 3 Metal
E 5 Metal
E 7 Metal
S 9 Metal
W 12 Metal
W 12 Metal
N 13 Metal
N 15 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0,65 0,25 Y 24.0 ft2 2 ft 0 in
0.65 0.25 Y 36.0 ft- 2 ft 0 in
0.65 0.25 Y 18.0 ft2 2 ft 0 in
0.65 0.25 Y 18.0 ft2 2 ft 0 in
0.65 0.25 Y 18.0 ft2 2 ft 0 in
0.65 0.25 Y 8.0 ft- 2 ft 0 in
0.65 0.25 Y 8.0 ft2 2 ft 0 in
0.65 0.25 Y 64.0 ft- 2 ft 0 in
0.65 0.25 Y 36.0 ft2 2 ft 0 in
1 ft 4 in
1 ft 4 in
1 ft4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height
Exposed Wall Insulation
1
575 ft2
575 ft2
23 ft 9 It
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50)
.000418
2072.7 113.79 214 .318
7
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/
None
COP:1 27 kBlu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
SEER: 16 35 kBtu/hr 1050 cfm
0.8 1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap Use SetPnt
Conservation
1
Electric
None
Garage
0.98 50 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
System Model # Collector Model #
Collector
Area
Storage
Volume
FEF
None None
ft2
8/29/2018 11:24 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 6
❑noun aenG-')nrr IMP[ IT SUMMARY CHECKLIST REPORT
DUCTS
--- Supply--
—
Return --
Air
CFM 25
CFM25
HVAC #
V # Location R-Value
Area
Location
Area
Leakage
Type
Handler
TOT
OUT ON
RLF
Heat Cool
_ 1 Attic
6 150 ft'
Attic
15 ft'
Default Leakage
AHU CLST (Default) c(Default) c
1 1
I
TEMPERATURES
Programable Thermostat:
N
Cr(eiling Fans:
Feb
r
May
Jun
[X]
] Jul
[JCS
[ ] Aug
[�J
l 1 $ep
Oct
11
j[Xj] Nov
HDec
Venting Jan
Feb
Mar
Apr
[
May
Jun
E 1 Jul
11 Aug
l 1 Sep
[X] ov
Dec
Thermostat Schedule: HERS
2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling(WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling(WEH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Heating (W D)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating,(WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft'
0 ft
0.3
AHU 1
Default(8 lbs/sq.ft.
0 f?
0 ft
0.3
AHU 2
Default(B lbs/sq.ft.
0 ft.
0 ft
0.3
AHU 3
Defauln lbs/s .ft.
O ft'
O ft
0.3
AHU 4
Name:
Rating Compant:
8/29/2018 11:24 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: FRAN BISHOP Builder Name: BISHOP HOMES, LLC.
Street: 3608 GROVE COURT Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
U
Owner: Jurisdiction: ST LUCIE COUNTY
W
x
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed:
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring a
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -Floor or drywall.
Concealed
When. required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover Plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
8/29/2018 11:24 AM EnergyGaugeO USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 93
The lower the Energy Performance Index, the more efficient the home.
11. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
35.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1890
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.650
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.250
14. Heating system: Capacity
27.0
c) Area
7c.
230.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.98
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
20.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has co plie with the
Florida
Building Code, Energy Conservation, through the above energy
saving features which will be nstall d (or exceeded) i
is home before final inspection. Otherwis new EPL
display card will be comple d b ed on inst
c
complia features.
Builder Signature.
Date: z ?�
Address of New Home: 3608 GROVE COURT ICity/FL Zip: FORT PIERCE. FL
8/29/2018 11:24:37 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Project Summary Date: Aug 29, 2018
wrightsoft® Entire House By:
QUICK CALCS, INC.
/'317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM
Project Information
For: FRAN BISHOP, BISHOP HOMES, LLC.
3608 GROVE COURT, FORT PIERCE, FL
Notes:
Design Information
Weather: Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 42
OF
Outside db
90
OF
Inside db 70
OF
Inside db
75
OF
Design TO 28
OF
Design TO
15
OF
Daily range
M
Relative humidity
50
%
Moisture difference
61
gr/lb
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure 21943
Btuh
Structure
17777
Btuh
Ducts 5820
Btuh
Ducts
8324
Btuh
Central vent (0 cfm) 0
Btuh
Central vent (0 cfm)
0
Btuh
Humidification 0
Btuh
Blower
0
Btuh
Piping 0
Btuh
Equipment load 27764
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Infiltration
Equipment sensible load
24796
Btuh
Method Simplified
Latent Cooling Equipment
Load Sizing
Construction quality
Average
Fireplaces
0
Structure
3448
Btuh
Ducts
2255
Btuh
Heatingg
Coolingg
Central vent 0 cfm)
0
Btuh
Area (ft2) 1890
1890
Equipment la Ent load
5703
Btuh
Volume (fta) 17577
17577
Airchanges/hour 0.38
0.20
Equipment total load
30499
Btuh
Equiv. AVF (cfm) 111
59
Req. total capacity at 0.70 SHR
3.0
ton
Heating Equipment Summary
Cooling Equipment Summary
Make
Make Trans
Trade
Trade TRANE
Model
Cond 4TTR6036B1
AHRI ref
Coil TEM6AOC36H31++TDR
AHI ref 7795577
Efficiency 100 EFF
Efficiency 13.0 EER, 16
SEER
Heating input 7.5
kW
Sensible cooling
24500
Btuh
Heating output 25721
Btuh
Latent cooling
10500
Btuh
Temperature rise 20
OF
Total cooling
35000
Btuh
Actual airflow 1167
cfm
Actual airflow
1167
cfm
Air flow factor 0.042
cfm/Btuh
Air flow factor
0.045
cfm/Btuh
Static pressure 1.00
in H2O
Static pressure
1.00
in H2O
Space thermostat
Load sensible heat ratio
0.82
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrightsoft•
2018-Aug-2911:25:26
Right -Suite® Universal 2017
17.0.08 RSU08101
Page 1
-4C'pE:WccumnetslWrightsoR HVAC\FRAN BISHOP.rup Cafe
=MJ8 Front Door faces: W
wrightsoftRight-M Worksheet Job:
Entire House Date: Aug 28, 2018
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM
1
Room name
Entire House
MASTER BEDROOM
2
3
F)posed wall
Room height
177.9 ft
9.3 If
43.0 ft
9.3 ft heat/cod
4
Room dimensions
1.0 x 299.0 ft
5
Room area
1890.0 ft2
299.0 ft2
Ty
Construction
number
U-value
(Btuh/ft2-°F)
Or
HTM
(Btutdft2)
Area (ft2)
or perimeter (ft)
Load
Stuh)
Area (fe)
or perimeter (ft)
Load
(Bluh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
NIP/S
Heat
Cool
6
.
j
13A focs ._7
2 glazing, clr low,e ,._-
9 9
13A-0ocs
0 143
_._„-_ 0.650
0.143
- n
-,_n_
a
3.85
-_17.49
3.49
2.57
_15.32
2.97
577
..-_..�140
118
" 50
0
121
-__..._
2080
_ T-629
a 1392
313
313
'--158
.__� 0
0
158
-.__._0
0
! 608
__.-_._ _0.
0
-_�...
407
0
V+1
11
�j
2 A-4oc dr,low-e
13A-0ocs
2 glazing, clr love
2glazing clrlo
2 glazmg clr lower
111)0.._ -_
---0.650
0650
0650
0650
0.650
-0.390
a
s
a
s
s
_s_
17.49
- 349
1749
1749
17.49
-10.49
32.57
5.32
15.32
15.32
15:32
-_111.39
18
78
8
8
24
_-_-24
�_ _- 1
513
8'
8
24
_-.24
315
972
-'1140
140
0
42420
_-_252
593
1123
123
368 368
-,er273
__ 0
110
0
0
24
.-_-_--_-:0
,- 0
88
0
0
24
_._-___0
„-, _ 0
-"330
0
0
420
--0
0
---�220
0
0
368
___0
13A4ocs
0.143
w
3.85
2.57
363
227
872
584
130
94
362
242
�G
`G
Cis,,.: ;
2 glazing, clr low-e
2 Glazing, clr Ipwe _
16A-30md_�.-
0.650
0.650
.__._.,0.032
w
w
�„,„
17.49
1749
�:._0.86
32.97
33.25
,'� 2.33
72
64
,._�1890
4
_ - 3
- .,1890
1259
_ ,1119
1627
2374
___ 2128
.�_4397
36
�__ . 0
.�.,�299
2
__,_,_ _ 0
,299
629
_- 0
�1.257,
1187
,--_ 0
_7.696
F. _.. ..
22A-tph.---
_-358
-
36.53
-- goo
1890
178
6499
__-.p- 0
299
43
1571.
_..._ _ 0
6
c)AED mursion
1387
330
Envelope loss/gain
17790
15924
4185
3455
12
a) Infiltration
3290
998
795
241
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
1200
0
Subtotal (lines 6to 13)
21081
18122
4980
3696
Less eMemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
21081
18122
4980
3696
15
Duct loads
27%
46%
5680
8388
27% 1
46%
1342
1711
Total room load
26761
26510
6321
5407
Air required (cfmj
1167
1167
276
238
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
/C, A wrlghtsoR' Right -Suite® Universal 201717.0.08 RSU08101 2018-Aug-28 1 :37:45
1
E:\Documnels\Wrightsoft HVAC\FRAN SISHOP.rup Calc= MJB. Front Door faces:S
9
wrightsoft, Right-M Worksheet Job:
Entire House Date: Aug 28, zota
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Enall: QUICKCALCS@AOL.COM
i
Room name
M W IC
M BATH
2
Egwsed wall
9.0 ft
16.0 it
3
Room height
9.3 ft heaVcool
9.3 ft heat/cool
4
5
Room dimensions
Room area
9.0 x 8.0 ft
72.0 f?
1.0 x 152.0 ft
152.0 ft-
Ty
Construction
U-value
Or
HTM
Area (W)
Load
Area (ft')
Load
number
(Btuidf -F)
(Stuh/ft')
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Bluh)
Heat
I Cool
Gross
N/P/S
Heat
Cool
Gross
NIP/S
I Heat
Cool
6
_,._-.
yy �
13A400s�__,--
.,_� _
0143
'' n'-385
—"2:57
- r84
-"�84
----322
—215
149
— 131
—500
--.- -337
2 glazing_clr.low�:,-,-
13A4ocs
-.__0 650
0.143
_n._
a
_17.49
3.85
_15.32
2.57
_-_„__s0
0
__-315
0
— _276
0
y/
,-._.--._,_,0
0
_„__O
0
-._.___0
0
--18
0
—0
0
11
—
-
2 olazinq. clr low-e„Y,
13A4ocs
0.650
0143
a
—s-
17.49
385
32.97
- -.2.57
0
"—�"m 0
_ 0
�0
0
�0
---0
_ _� 0
—0
0
.'__0
_,�0
0
0
____.._- 0
~Y0
2 glazing clrlow-e
2 glazing clr Iowa
2 glazing clr low-e
0650
0.650
0.650
s
s
s.:
1749
1749,
1749
15.32
15.32
15.32
0
0
0
0
0
0
0
0
0
0
0,
0
0
0
0
0
0;
0
0
0'
0
0
0
0
11D0___�._...._.
0.390
_s_
—10.49
'_.._,11.39
---0
--—0
--..0
____0
--0
—0
—_0
13A4ocs
0143
w
385
2.57
0
0
0
0
0
0
0
0
2 glazing or lows
2 glazinq clr lower_--_
,10 30md'_.::,�.;a
0690
0.650
._,._.�._____0.032
w
w
`„�:_
1749
17.49
7— 086
32.97
-33.25
.2.33
0
0
_=,_ `72
0
0
,„_--,,_„__72
0
_ __ 0
.;,__62
0
0
_,_168
0
0
,�152
0
. 0
�_�,_152
0
_-_ . 0
,� __131
0
, - 0
F
22A-lph_„
1.358
36.53
0.00
72
9
329
0
152
_ 16
584
0
77,
6
c)AED muision
-11
-26
Envelope loss/gain
713
372
1533
940
12
a) Infiltration
166
50
296
90
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
879
423
1829
1029
Less wdemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
879
423
1829
1029
15
Duct loads
27%
46-/U
237
196
2r/
46%
493
476
Total room load
1
1
1116
618
2322
1606
Air required (cfm)
49
27
101
66
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed
h -Fk wrightsaft- RighlSuite® Universal 201717.0.08 RSU08101 2018 Aug 281 :337.:455
E:\Documnels\Wrightsolt HVAC\FRAN SISHOP.rup Cale = MJ8 Front Door faces: 8 g
wrightsoftRight-JO Worksheet Job:
Entire House Date: Aug 28, zola
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM
i
Room name
WIC 2
BEDROOM 2
2
3
E posed wall
Room height
6.0 It
9.3 it heat/cool
14.0 it
9.3 it heat/cool
4
5
Room dimensions
Room area
6.0 x 8.0 it
48.0 f?
1.0 x 180.0 it
180.0 ft2
Ty
Construction
number
U-value
(Btuh/ft;*F)
Or
HTM
(Stuh/fN)
Area (W)
or perimeter (ft)
Load
(Btuh)
Area (ft-)
or perimeter (ft)
Load
(Btuh)
Heat
I Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
11
W
13A-0a`cs-��
2 glazing; clr lav-e__.
13A4ocs
2 olazina.,cIr Im;e
13A4ocs ,
2 glazing clr Iowa
2 glazing clr Iowa
2glazing• clr Iowa
11DO,_._.._._.._._.
-Or143
-_._0.650
0.143
0.650
- -0143
- 0.650
0650
0650
-0.390
ri
-n�
a
a
s-
5
s
s
_s_
-- 3.85
,w17,49
3.85
17.49
.»_ 3.85
17.49
1749
1749
-10.49
' 2.57
�15:32
2.57
_32.97
2.57
15.32
15.32
15.32
_.11.39
'�'�b6
„_____0
0
0
0
0
0
'0
....._._._.0
- "-56
'._�_0
0
0
0
0
0
0
--0
---215
__�0
0
- 0
_0
0
0
0
---144.
_,_._.0
0
0
_ .__...- 0
0
0
0
" 130
_„_- 18
0
-_0
0
0
'0
0
:---112
-__0
0
_„__0
0
0
0
0
432
_v_ 315
0
__._. 0
0
0
0
0
i-- 289
____ 276
0
_ _ _ 0.
0
0
0
0
.__ __ _0
t-G
r
-
y/
_.-0
0
.__-._0
0
_._--,0
0
__.-_0
0
----_0
0
13A-4ocs
0143
w
385
2.5/
0
0
0
�L-GC
C,�_..:16A-30md„T_
2 glazing, clr low-e
2 glazino, clr Iowa
0.650
_ 0650
0 032
w
w
r .,
_�._
17.49
1749
:_0 86
32.97
33.25
;�._-,2:33
0
0,0
=.. =� 48
0
=48
0
0
_.� 41.
0
_.._,.�_. 0-��_0
,_.__.:112
0
____180
0
__ 0_r.,
-.� 180
0
0
__755
0
_,_ 0
_.___419
F ...-__
22A-tph-,_�__._
.___.. i_359
.
-
_ 36.53
0.00
.�._
48
_,.. 6
219
_ 0
180
._..
_ i 14
--511
- 0
.r__.
_..._._..�.......
�.._..�,_.__..
,.......�
___.�
._�.e
�..._......-.._._
-_
�.__,
_._ _ _
6
c)AED excursion
-7
-39
Envelope loss/gain
475
248
1413
944
12
a) Infiltration
ill
34
259
78
b) Room ventilation
0
0
0
0
13
Intemal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
500
Subtotal (lines 6 to 13)
596
282
1671
1523
Less extemal load
0
0
0
0
Less transfer
0
01
0
0
Redistribution
0
0
7
19
14
Subtotal
586
282
1679
1542
15
Ductloads
27%
46%
158
130
27%
46%
452
714
Total room load
744
412
2131
2255
Air required(cfm)
32
18
93
99
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed
�„ `A T+ wrightSoft- RightSuite® Universal 2017 17.0.08 RSU08101 2018-Aug-28 1 :37:45
3
E:\Documnels\Wrightsoft HVAC\FRAN BISHOP.rup Calc = MJB 'Front Door faces: 8
9
I wrightsoft Right-J® Worksheet Job:
Entire House Date: Aug 28, 2018
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772A66-6796 Emil: QUICKCALCS AOL.COM
1
Room name
M TOILET
BATH 2
2
Exposed wall
0 ft
0 it
3
Room height
9.3 It heat/cool
9.3 ft heat/cod
4
Room dimensions
6.0 x 3.0 It
8.0 x 7.0 It
5
Room area
18.0 ft2
56.0 ft2
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft2)
Load
number
(BtuWfti°F)
(Btuh/ft2)
or perimeter (ft)
(Bluh)
or perimeter (it)
(Bluh)
Heat
I Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cod
6
i�,13A-0oos
_.._.._
0143
n..
�- 385
...�2.57.
-�-"..0
0
'�_0
—._
___ 0
__..___---'-0
0
____Q
�_— 0—_0
.
0
—0
2 glazing, clrjow e_._.._._0
650
_n_
-_17.49
__15.32
____0
__-_0
_—.-_0
-
- __
0
._.-0
0
0
13A-4ocs
0.143
a
3.85
2.67
0
0
0
0
0
.
tV,J
-
2.ala ina, clr laws
0.650
e_
17.49
32.97
0
0
0
_-
- _„__ 0
T._ _ 0
11
. .
V�1
13AAMS
�"0143
s
--3.85
_
� 2.57
_0
0
��"0
�0
�"-0
�0
0
_�_�0
0
.
0
0
2 glazing, clr Iowa..
- 0650
s
1749
15.32
0
0
'0
0,
0
0
D
0
2 glazing; ctr, lowe
0.650
s
17.49
15.32
0
0
0.
0
0
0
0
0
IFS--GCD
2 glazmg, cir lowe
0.650
s,
17.49
15.32
0
0
01
0
0
0
0
0
iiDO____y_.._.�
_.-0.390
-a-
_-._10.49
_.._.11.39
._...__0
_--_0
----0
_.._0
,..._..__0
._m_____0
___ _0
------- 0
1�
13A-0ocs
0.143
w
3.85
2.57
0
0
0
0
0
0
0
0
I---C
2 glazing, clr Iowa
0.650
w
17.49
3297
0
0
0
0
0
0
0
0
III------fGGi
2 alazina, dr Iowa
0.650
w
17.49
33.25
0
0
0
0
0
0
0
0
`Cr
i6A-3omd-w-._.,
-.__ 0.032
_._0.86
_„_2.33
_
18
_.
.T18
_._..�ry„_ 15
w -_42
_=,=56
,._56
„
_____ 48
-_ -
�_-,-.130
F
22Atph_-y
1.358
-
3653
0.00
18
_, 0_.,YO
0
56
0
0
0
J
..-�. _...-.
tee...._.-m......._...-..-.e.�
�_..�_.
..�..
___.mow
r..-..
.�.�r--
�•___.�..-....»_.
__.�...
.�.-..
� ..-.
._ ._
6
c)AED excursion
-1
-8
Envelope loss/gain
15
41
48
122
12
a) Infiltration
0
0
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
200
Subtotal (lines 6 to 13)
15
41
48
322
Less a#emal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
11
28
14
37
14
Subtotal
26
69
62
359
15
Duct loads
1 27%
46%
7
32
27%
46%
17
166
Total room load
33
101
79
526
Air required (cfm)
1
4
3
23
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed.
ACA -Fk- wrightsof!' Right -Suite® Universal 201717.0.08 RSU08101 2018-Aug-28 1 Page 4
EADocurmets\Wrightsoft HVAC\FRAN BISHOP.rup Cale =We Front Door faces: S
wrightsoft' Right -A) Worksheet Job:
Entire House Date: Aug 28, zota
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466,6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM
1
2
3
4
5
Room name
Eltrosed wall
Room height
Room dimensions
Room area
LAUNDRY
0 ft
9.3 ft heat/cool
10.0 x 7.0 ft
70.0 ft2
AHU CLST
4.0 ft
9.3 It heat/cool
4.0 x 5.0 ft
20.0 ft?
Ty
Construction
number
U-value
(Btut✓ftz°F)
Or
HTM
(Btuh/ft2)
Area (re)
or perimeter (ft)
Load
(Btuh)
Area (fe)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/PIS
Heat
Cool
Gross
NIP/S
Heat
Cool
6!
11
13A-0oc's
2 glazing ; dr, laws_.
13A4ms
2 oledna,clr low-e
13A-4ocs
2glming cir lowe
2 glazing clr lowe
2 glazing clr lowe
0143
- 0650._n_
0.143
0.650
------ 0143
0650
0.650
0.650
___0.390_s__-10.49_....:11.39
- n
a
_e.,,
s
s
s
s
3 85
_.__1749
3.85
1749
'- 3.85
1749
17.49
17.49
2.57
__15.32
2.57
32.97
2.57
15.32
16.32
15.32
_"`0
_-_0
0
_ 0
0
0
0
0
0
0
___-_0
0
, 0
' 0
0
0
0
0-_._-0-
'--0
-__.__0
0
___ 0
"0
0
0
0
_-._ U
--, -0
0
__ �0
ry 0
0
0
0
-0---0---
__._0
.0
0
.-_ 0
-37'
0
0
0
_ �..0
_„,0
0
_ 0
37
0'
0
0
-0�-_0-_._,0
.__, .0
___0.
0
_ 0
143
0
0
0
_____ 0
,,--.__.0
0
, -__ 6
9
0
0
0
W, --
LG
1N •,'; "
y/
�C
;C -_.
13A4ocs
2 glazing, Gr low-e
2 glazing, clr lower �,
16A30md=,, =
0.143
0.650
T_. 0.650
-.�_0 032
w
w
. w
.^,,,.
3.85
17.49
17.49
�_0.86
2.67
3297
-�33.25
___233
0
0
,_� 0
_„___„70
0
0
_ 0
_7=-70
0
0
_ 0
,��_60
0
0
0
0
0
.__�. 0
_�20
0
0
0
_=--20
0
0
__ _ 0
�77
0
0
.__� 0
47
A.
;163
F
22A;tph._u--,,,
1.358
;_
_36.53
0.00
70
0
_0
0
_ 20
4
W_ 146
- -_ 0
._w
6
c)AED excursion
-16
4
Envelope loss/gain
60
146
306
138
12
a) Infiltration
0
0
74
22
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
500
0
Subtotal (lines 6 to 13)
60
646
380
161
Less e)temal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
176
90
-380
-161
14
Subtotal
236
736
0
0
15
Duct loads
27%
46%
CA341
M.
46%
0
0
Total room load
300
1077
0
0
Air required (cfm)
13
47
0
0
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed
ACZ__`A -ro- wrightsOR- Right -Suite® Universal 201717.0.08 RSU08101 2018-Aug-28 1 :37:45
5
E:\DocumnetslWrightsoft HVAC1FRAN BISHOP.rup Cale =MJB Front Door faces: S
9
wrightsoft Right-M) Worksheet Job:
Entire House Date: Aug 28, zota
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM
1
Room name
STUDY
HALL
2
3
E14losed wall
Room height
22.0 It
9.3 It heat/cool
0 1t
9.3 It heat/cool
4
5
Room dimensions
Room area
15.0 x 12.0 It
180.0 W
18.0 x 4.0 It
72.0 ft'`
Ty
Construction
number
U-value
(BtuIVftMF)
Or
HTM
(Btu)Vft-)
Area (ft2)
or perimeter (ft)
Load
(Btuh)
Area (fe)
or perimeter (ft)
Load
(Btuh)
Heat
I Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
'2 gla ng,.ciclow a -v
13A4ocs
__ 0650
0.143
_n_.
a
_ _17.49
3.85
�.15. 2
2.57
�_.LA
65
-- _
0
---0 47
__�..�
----0 1
181
._._�,.._._.._.0
..._.. 21
121
0
0
_...-__...
0
_,0
0
�` 0
_._._._0
0
.___. _
0
_ 0
� 0
Vy
11
1--G
2clazino _clr lc a ,,.,,
13A-0ocs
2 glazng,.cir lovv�
2 glazing, clr Im-e
2glazing, clr Im-e
11D0. __.._...V.._
_..._.,.,.0.650
0143
0650
0650
`0650
_._0390
a
s -
s
s
s
_.s_
17.49
� ! 3 85
1749
1749
1749
_._...1049
32.97
---2.57
15.2
15.32
15.32
-__11.39
18
r _ 140
0
0
0',
-0,-_0
„1
_._......-140
0
0
0
-_ 315
537
0,
0
0.
---0
__._ _593
359
0,
0
0
_-__0
._._ 0
--- 0
0
0
0
._ -0
_ __ 0
Y.--__ 0
0
0
0
�__0
0
0
0
. 0
0
__-0
0.
0
0
0
0
.__v _,.0
.
Vy
---GG
_
C.:._.._
13A-4ocs
2 glazing, clr low-e
2dazinp. clr Im-e-
_16A-30md�, .
0.143
0650
0650
_Y0 032
w
w
w
_
3.85
1749
1749
y6.86
2.57
32.97
_33.25
-2.33
0
0
0
=_..180
0
0
0
a f 180
0
0
0
%5
0
0
-, .0
,--__-419
0
0
_..__._ 0
_�72
0
0
0
._72
0
0
__0
_Y_- _..__62
0
0
_._._ 0
_ _ 168
F
22A4ph
1358
-
3653
0.0a
180
22
804
0
72
0
0
0
::�_
...... -- _.,,_ .a_-•___
__._mil
_-...
_.._..
- _ _._._.
�._.._v
_. �.,
f__._.. _.
� _ .� ._
.__ , � �
._ __.
_ __.._ _
�.__...._.
A.a%.•......
6
c)AED excursion
-21
-4
Envelope loss/gain
1991
1471
62
163
12
a) Infiltration
407
123
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (fines 6to 13)
2398
1595
62
163
Less wdemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
230
139
-62
-163
14
Subtotal
2628
1734
0
0
15
Duct loads
27%
46%
708
803
27%
46%
0
0
Total room load
3336
2537
0
0
Air required (cfm)
145
112
0
0
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed.
wrlghtsof - Right -Suite® Universal 201717.0.08 RSU08101 2018-Aug-28 1 :37: 5
EDocumnels\Wrlghlsoft HVAC\FRAN BISHOP.rup Cale = M.18 Front Door faces: S 9
wrightsoft Right-M) Worksheet Job:
Entire House Date: Aug 28, zota
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466.6796 Email: QUICKCALCS@AOL.COM
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
STUDY CLST
O ft
9.3 ft heat/cool
2.0 x 3.0 ft
6.0 ft2
LINEN
O ft
9.3 ft heat/cool
7.0 x 3.0 ft
21.0 ft2
Ty
Construction
number
U-value
(Btuh/ftUF)
Or
HTM
(Btuh/ft2)
Area (ft2)
or perimeter (ft)
Load
(Btuh)
Aroa (ft2)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
I N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
11
0143
_-_0 650
0.143
_,0.650
0143
.0 650
0.650
0650
--0390
0.143
0.650
0.650
_._0.032
n'
-n_
a
_e_
s
s
s
s
__s_
w
w
w_
!.,�,
_�_
,1385
, :-,1749
3.85
17.49
- 385
. 17.49
' 17.49
1749
-1049
3.85
17.49
�, 17.49
,_0.86
36.53
rfS7
!_„'„15.32
2.67
32.97
77 2.57
15.32
15.32
15.32
-11.39
_a
----0
0
0
..____0
„-,__-0
0
0
P.^-0
0
0
0
--._.._.0..._-
_..__ 0
_-0
0
_,0
_. _.0
0
0
0
0
--0
-0
0
0
_ 0'�
0
0
0
-0
_-_0
-._-_0
0
0
-0
0
0
0
0-0
_-0
-_.,,._0
0
0
�o
0
0
'0'
_____ 0
- -0
0
_0
_.� 0
. 0
0
0
.-_-0
_--;0
---.-0
Y 0
._,_ 0
`�'0
- .0
0
0
_-0
V!
Y--G2
vp�
�C
�G
�C�,_
-13A-0ocs --
2 glazing, clr,low-e.,-.-:y
13A-4ocs
alaziha, clr low-e
.13A4ocs ,
2 glazing, or low-e
2 gluing, clr low-e
2, glazing,clrrlow-e
_11D0
13A4ocs�
2 glazing, clr low-e
2 alazina, clr Iowa
96A-30md�-- .
,tp
�.0
0
0
0
�0
2.57
32.97
33.25
- - 2.33
0.00
0
0
0
'6
6
0
0
0
,M6
0
0
0
0
„ �-�5
0
0
0
0
0
0
__,.- 0
_._ 21
21
0
0
0
_-��21
0
0
0
_ 0
�__18
0
0
0
___ 0
-=49
0
�_
_-_,_ 14
0
6
c)AED excursion
0
A
Envelope loss/gain
5
14
18
48
12
a) Infiltration
b) Room ventilation
0
0
0
0
0
0
0
0
13
Internal gains: Occupants @ 230
Appliances/other
0
0
0
0
0
0
Subtotal (lines 6to 13)
5
14
18
48
14
15
Less external load
Less transfer
Redistribution
Subtotal
Duct loads
27%
46%
0
0
5
0
0
0
0
-14
0
0
27%
46%
0
0
-18
0
0
0
0
48
0
0
Total room load
Air required(cfm)
0
0
0
0
0
0
0
0
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
'et,
-il+ wrightsaft- RightSuile@ Universal 201717.0.08 RSU08101 2018-Aug-28 1 Page 7
E10ocumnetsMightsoft HVAMFRAN BISHORrup Calc = MJB Front Door faces: S
wrightsoft° Right-JO Worksheet Job:
Entire House Date: Aug 28, 2818
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM
1
Room name
IQTCHEN
GREAT ROOM
2
3
Exposed wall
Room height
25.0 ft
9.3 It heaticool
11.9 If
9.3 ft heat/cool
4
5
Room dimensions
Room arm
1.0 x 241.0 it
241.0 ft2
1.0 x 273.0 It
273.0 ft2
Ty
Construction
number
U-value
(Btut✓fti°F)
Or
HTM
(etuh/ft2)
Area (ft-)
or perimeter (ft)
Load
(Btuh)
Area (ft.)
or pedmeter (ft)
Load
(Btuh)
Heat
I Cool
Gross
NtP/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
y! •.
13A4ocs .�
2 gIazing,Ar.I w7e:.__
13A-4ocs
�•.�.'0 tA3
i_____0650
0.143
n
,n.-
a
-3.85
--17.49
3.85
-'2.57
_15.32
2.57
-0
_0
74
' 0
--0
74
--,U
-__--. 0
286
-'_ 0
_.__.,0
192
0
_0
0
0
_-__..-0
0
-_' o
0
---0
,_--.0
0
y/
0
11
J--G
2olazino.,clrlow,
13A-4ocs,
0.650
-'0143
e�
s
v17.49
r 385
32.97
- 2.57
0_
158
0
118
0
~- 454
0,
--304
0
0
0
_-' 0
0
'__._�0
--0--0
".2 glazing'clr low-e
2 glazing, dr, lower
2 glazing, ciclow-e
:11D0..__-.
0650
0650
0.650
i :._.0.390
s
s
s
_s_
1749
1749
1749
.--,_.10.49
15.32
15.32
15.32
�11.39
8
8
0
_..._._-24
8
8
0
_.._._24
140
140
0
.-.._.252
123
123
0
-273
0
0
0
._ -0
0.
0
0
---0
-0
0
0
----0
0
0
0
___0
_
13AAms
0.143
w
3.95
2.57
0
0
0
0
112
48
183
123
2 glazing, clr lower
2 glazinq,.clr lower
16A-30rad',_.._
0.650
_ 0650
�:0.032'
w
w
17.49
17.49
'w0.86
32.97
33.25
--2.33
0
0
=~M241
�241
0
„_,r.,-„ _0
w241
0
_ 0
,�207
0
_ 0
�__-,_,_561
0
64
-�273
0
____�- 3
=273
0
1119
`�235
0
�2128
_^ 635
F
22A-tph
1.358
�„-
36.53
0.00
25
913
0
273
12
._ 435
0
----
Y
6
c)AED excursion
-43
799
Envelope loss/gam
2393
1532
1972
3685
12
a) Infiltration
462
140
222
67
b) Room ventilation
0
0
0
0
13
Irltemal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
2855
1672
2194
3752
Less erdemel lead
0
0
0
0
Lesstransfer
0
0
0
0
Redistribution
15
39
13
33
14
Subtotal
2870
1711
2207
3785
15
Duct loads
27%
46%
773
792
27%
46%
595
1752
Total room load
3643
2503
2801
5537
Air required (cfm)
159
110
122
244
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed.
-IJFF wrlghtsoft- RightSuiteO Universal 201717.0.08 RSUDS101 2018-Aug-28 1 Page 8
EADocumnets\Wrightsoft HVACIFRAN BISHORrup Celc = MJ8 Front Door faces: S
P� wrightsoft Right-M Worksheet Job:
Entire House Date: Aug 28, zo,a
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:. 772466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM
1
Room name
DINING
2
E-posed wall
27.0 ft
3
Room height
9.3 If heaticool
4
5
Room dimensions
Room area
14.0 x 13.0 It
182.0 ft'
Ty
Construction
number
U-value
(Btuh/ftMF)
Or
HTM
(Btu[Vf2)
Area (ft')
or perimeter (ft)
Load
(Btuh)
Area
or perimeter
Load
Heat
I Cool
Gross
N/P/S
Heat
Cool
Gross
N/P!S
Heat
Cool
6
'13A-06Z-s7-..-...
__.0143
-.n'
—,._3.85
"-'-257
—_-0
2 glazing;.cl low-e _
13A-4ocs
,_ 0.650
0.143
_ n_
a
17.49
3.85
-., 15.32
257
0
0
0
0
0
W
11
�--f'
4�/��(C'
2 olazmq clr Iowa
SA -flocs - _
0.650
~^_0143
_ e
s
17 49
3 85
32.97
2
0
130
0
_57 130
0
' 501
_ 0
335
2 glazmg clrlow-e
2glazing clr low-e
2 glazing, clglow-e
0.650
O650
0650
s
s,.
s
i 17.49
1749
17.49
16.32
15.32
15.32
0
0
0
0
0.
0
0-
0
0
0
0
0
LD
11D0.._... _
--0.390
_s_
_..10.49
—11.39
....._.._....._J.0
_.._.._:0....__
_.0
_.___0
'
y/
13A-4ocs
0.143
w
3.85
257
121
85
327
219
.._
2 glazing clr Iowa
2 glazmg, clr_low;e
- �_.
16630md,_.__........_
0.650
T_... 0.650
_ 0.032
w
w,
__.
17.49
1749
,,,,,_ 0.36
32.97
33.25
--_„233
36
0
.�.�_182
2
.__ 0
._,�_127
629
_ 0
57
�.,_ 986
1187
0
F..-.-._
22A:tph___�„.
1.358.E
36.53
0.00
182
_. 27
986
6
c)AED excursion
440
Envelope lom/gain
2600
2604
12
a) Infiltration
499
151
b) Room ventilation
0
0
13
Internal gains: Occupants @ 230
0
0
Appliances/other
0
Subtotal (lines 6 to 13)
3099
2755
Less external load
0
0
Less transfer
0
0
Redistnbution
0
0
14
Subtotal
3099
27M
15
Duct loads
2M
46%
$35
1275
Total room load
3934
4030
Air required (cfm)
172
177
JJ ,, Calculations approved bvACCA to meet all requirements of Manual J 8th Ed.
T� wrightsofi' RightSuile4D Universal 2017 17.0.08 RSU08101 2018 Aug 28 1 page 9
E:\Dccumnets\Wrightsoft HVAC\FRAN BISHOP.rup Colo = MJ8 Front Door faces: 8
-�- wrightsot
Duct System Summary Date: Aug28,2018
Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: OUICKCALCS a@AOL.COM
Project Information
For. FRAN BISHOP, BISHOP HOMES, LLC.
GROVE STREET, VERO BEACH, FL
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual airflow
Total effective length (TEL)
Heating
1.00
in H2O
0
in H2O
1.00
in H2O
0.500 / 0.500
in H2O
1.000
in/100ft
1167
cfm
206
Cooling
1.00
in H2O
0
in H2O
1.00
in H2O
0.500 / 0.500
in H2O
1.000
in/100ft
1167
cfm
Supply Branch Detail Table
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FIR
Diam
(in)
H x W
(in)
Duct
Mat]
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH
c 526
3
23
1.000
5.0
OxO
VIFx
32.1
135.0
st3
BEDROOM
c 2255
93
99
1.000
7.0
0x0
VIFx
16.5
115.0
st1
DINING
C 4030
172
177
1.000
8.0
0x0
VIFx
37.1
115.0
st2
GREAT ROOM
c 2769
61
122
1.000
7.0
0x0
VIFx
49.3
155.0
st4
GREATROOM-A
c 2769
61
122
1.000
7.0
0x0
VIFx
34.2
135.0
st3
KITCHEN
h 3643
159
110
1.000
7.0
OxO
VIFx
35.4
115.0
st2
LAUNDRY
c 1077
13
47
1.000
6.0
Ox0
VIFx
16.8
115.0
st1
M BATH
h 2322
101
66
1.000
6.0
Ox0
VIFx
31.9
135.0
st3
M TOILET
c 101
1
4
1.000
4.0
Ox0
VIFx
30.2
135.0
st3
Mwlc
h 1116
49
27
1.000
5.0
Ox0
VIFx
46.1
155.0
st4
MASTER BEDROOM
h 3161
138
119
1.000
7.0
Ox0
VIFx
47.7
155.0
st4
MASTER BEDROOM.A
h 3161
138
119
1.000
7.0
Ox0
VIFx
51.0
155.0
st4
STUDY
h 3336
145
112
1.000
7.0
Ox0
VIFx
17.8
115.0
st1
WIC
h 744
32
18
1.000
4.0
Ox0
VIFx
21.6
115.0
st1
Supply Trunk Detail Table
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FIR
(fpm)
(in)
(in)
Material
Trunk
st4
Peak AVF
385
387
1.000
710
10.0
0 x 0
VinlFlx
st3
st3
Peak AVF
553
603
1.000
768
12.0
0 x 0
V]nlFlx
st1
st1
Peak AVF
837
879
1.000
823
14.0
0 x 0
VinlFlx
st2
Peak AVF
330
288
1.000
748
9.0
0 x 0
VinlFlx
htsoft° 2018-Aug-2815:37:47
wr1
�. 9 Right -Suite® Universal 201717.0.08 RSU08101 Page 1
A EADocuwels\Wrightsoft HVAC\FRAN BISHOP.rup Cale = MJ8 Front Door faces: S
Return Branch Detail Table
Name
Grill
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FR
Veloc
(fpm)
Diam
I (in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb1
Ox0
1 1167
1167
0
1 0
0
0
Ox 0
1
VIFx
^, wrightsoft° 2018-Aug-2815:37:47
RlghiSuile® Universa12017 17.0.08 RSU08101
Page 2
�'C'AE:\Documnets\Wnghtsoft HVAC\FRANBISHOP.rup Calc=MJB Front Doorfaces: S
FORM 60OA-2004 EnergyGauge® 4.0
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
_ Florida Department of Community Affairs S
Residential Whole Building Performance Method Af �y
Project Name: New Project LOURAN / SUSANA 11 1291 Builder: LOURAN % �n'
Address: Permitting Office: C� O
City, State: Permit Number: 04�
Owner: Jurisdiction Number:
Climate Zone: Central
L New construction or existing
New _
2. Single family or multi-fanrih
Single family
3. Number of units, if multi -family
1 _
4. Number of Bedrooms
3 _
5. Is this a worst case"
Yes _
6. Conditioned Boor area (it!)
1291 it' _
7. Glass type I and area: (Label read. by 13-104.4.5 if not default)
a. U-faetor:
Description Area
(or Single or Double DEFAULT) 7a. (Sngle Default) 167.0 B' —
b. SHGC:
(or Clear or Tint DEFAULT) 7b.
(Clear)167.0 B'
S. Floor hpes
a. Slab -Oa -Gm de Edge Insulation
R=�0!0, 174.0(p) B _
b. NA
_
c. NA
_
9. Wall types
a. Concrete, Ltt InsuL Exterior
R=4.1, 940.0 11' _
b. Frame. Wtxxl. Adjacent
R=11.0, 246.0 B'
c. NA
_
d. NA
_
e. NA
_
10. Ceiling hpes
a. Under Attic
R=19 0! 1346.0 ft=
b. NA
_
c. NA
_
11. Ducts
_
a. Sup: Une. Ret: U nc. AH: Garage
Sup. R=6.0. 120.0 it
b. NA
12. Cooline *stems
a. Central Unit Cap: 30.0 kBtu hr
SEER:13mo _
b. NA
c. NA
13. Heatingsystems
a. ElNA ectri
b.c Heat Pump
:7?0
_
c. NA ��FILE
14. Hot water.~ -stems
a. Electric Resistance
b. NA
c. Conservation credits
(HR-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HVAC credits
(CF-Ceiling fan. CV -Cross ventilation.
HF-Whole house fan.
PT -Programmable Thermostat,
MZ-C-Multizone cooling.
MZ-H-Multizone heating)
Glass/Floor Area: 0.13 Total as -built points: 19880 PASS
Total base points: 20024
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the F�orida er
Code. h%r✓Jo- - �.vM,lk—
PREPARED BY:
DATE: 3 "10h �\
I hereby certify that this build' as designed. is
-compliance with the Flori a net y o
OWNER/AGENT:
DATE:
1 Predominant glass type. For
type and areas, see Summer & V
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
Jinter Glass output on pages 2&4.
EnergyGauge® (Version: FLRCSB v4.0)
Cap: 40.0 gallons _
EF:1! 92
a
p
FORM 60OA-2004 EnergyGauge® 4.0
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BSPM =
Points
Overhang
Floor Area
Type/SC
Omt
Len Hgt
Area X
SPM X
SOF
= Points
.18 1291.0
25.78
5990.8
Single, Clear
E
1.0 9.0
15.0
63.97
0.99
953.4
Single, Clear
E
1.0 6.0
30.0
63.97
0.97
1862.4
Single, Clear
W
10.0 4.0
21.0
67.68
0.40
487.4
Single, Clear
W
10.0 8.0
41.0
57.68
0.49
1166.8
Single, Clear �- '-
�IN
1A- 6'0
-15.0
57.68 �
0.97 '
839.4
Single, Clear
S
1.0 3.0
4.0
48.22
0.80
153.9
Single, Clear
S
6.0 8.0
41.0
48.22
0.61
1203.3
As$uilt Total:
167.0
6666.6
WALL TYPES
Area X
BSPM
= Points
Type
R-Value
Area
X SPM
=
Points
Adjacent
246.0
0.70
172.2
Concrete, Int Insul, Exterior
4.1
940.0
1.18
1109.2
Exterior
940.0
1.90
1786.0
Frame, Wood, Adjacent
11.0
246.0
0.70
172.2
Base Total:
1186.0
1958.2
As -Built Total:
1186.0
1281A
DOOR TYPES
Area X
BSPM
= Points
Type
Area
X SPM
=
Points
Adjacent
17.7
1.60
28.3
Exterior Insulated
20A
4.80
97.9
Exterior
20.4
4.80
97.9
Adjacent Wood
17.7
2.40
42.4
Base Total:
38.1
126.2
As -Built Total:
38.1
140.4
CEILING TYPES Area X
BSPM
= Points
Type
R-Value Area X SPM X SCM =
Points
Under Attic
1291.0
2.13
2749.8
Under Attic
19.0
1346.0
2.82 X 1.00
3795.7
Base Total:
1291.0
2749.8
As4Buitt Total:
1346.0
3795.7
FLOOR TYPES
Area X
BSPM
= Points
Type
R-Value
Area
X SPM
=
Points
Slab 174.0(p)
31.8
5533.2
Slab -On -Grade Edge Insulation
0.0
174.0(p
31.90
5550.6
Raised
0.0
0.00
0.0
Base Total:
5633.2
As -Built Total:
174.0
-5550.6
INFILTRATION
Area X
BSPM
= Points
Area
X SPM
=
Points
1291.0
14.31
18474.2
1291.0 14.31
18474.2
EnergyGauge® DCA Form 60OA-2004 EnergyGauge®/FIaRES'2004 R.RCSB v4.0
i
FORM 600A 2004
EnergyGauge® 4 0
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS:,,, PERMIT #:
BASE
AS -BUILT
Summer Base Points:
23766.0
Summer As -Built Points:
24807.7
Total Summer X System
=` Cooling
Total X Cap
X Duct X System X
Credit = Cooling
Points Multiplier
Points
Component Ratio
Multiplier Multiplier
Multiplier Points
(System - Points)
(DM x DSM x AHU)
(sys 1: Central Unit 30000 btuh ,SEERIEFF(13.0) Ducts:Unc(S),Unc(R),Gar(AH),R6.0(INS)
24808 1.00
(1.09 x 1.150 x 1.00) 0.262
1.000 8134.4
23766.0 - 0 4266'
" 10138.6"
' 248071 " 1.00
1.250' ""0.262 -
1.000 "_"81 X.4
EnergyGaugeTM DCA Form 60OA-2004 EnergyGauge®/FlaRES'2004 FLRCSB v4.0
FORM 600A-2004 EnergyGauge® 4.0
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BWPM =
Points
Overhang
Floor Area
Type/SC
Ornt
Len
Hgt
Area X
WPM X
WOF = Point
.18 1291.0
6.96
1361.7
Single, Clear
E
1.0
9.0
15.0
12.37
1.00
186.4
Single, Clear
E
1.0
6.0
30.0
12.37
1.01
374.3
Single, Clear
W
10.0
4.0
21.0
13.25
1.11
310.0
Single, Clear
W
10.0
8.0
41.0
13.25
1.10
595.3
Single. Clear`.. -- "--
W'-1:0-
" 15.0 -'-75.0'...
13.25`--
.1.00-
199.2
Single, Clear
S
1.0
3.0
4.0
9.90
1.12
44.2
Single, Clear
S
6.0
8.0
41.0
9.90
1.61
652.3
As -Built Total:
167.0
2361.7
WALL TYPES
Area X
BWPM
= Points
Type
R-Value
Area
X WPM
=
Points
Adjacent .
246.0
1.80
442.8
Concrete, Int Insul, Exterior,.
4.1
940.0
3.31
3106.7
Exterior
940.0
2.00
1880.0
Frame, Wood, Adjacent
11.0
246.0
1.80
442.8
Base Total:
1186.0
2322.8
As43uilt Total:
1186.0
3649.E
DOOR TYPES
Area X
BWPM
= Points
Type
Area
X WPM
=
Points
Adjacent
17.7
4.00
70.7
Exterior Insulated
20.4
5.10
104.0
Exterior
20.4
5.10
104.0
Adjacent Wood
17.7
5.90
104.3
Base Total:
38.1
174.8
As -Built Total:
38.1
208A
CEILING TYPESArea X
BWPM
= Points
Type
R-Value
Area X WPM X WCM =
Points
Under Attic
1291.0
0.64
826.2
Under Attic
19.0
1346.0
0.87 X 1.00
1171.0
Base Total:
1291.0
828.2
As43uilt Total:
1346.0
1171.0
FLOOR TYPES
Area X
BWPM
= Points
Type
R-Value
Area
X WPM
=
Points
Slab 174.0(p)
-1.9
-330.6
Slab -On -Grade Edge Insulation
0.0
174.0(p
2.50
435.0
Raised
0.0
0.00
0.0
Base Total:
-330.6
As -Built Total:
174.0
435.0
1
INFILTRATION
Area X
BWPM
= Points
Area
X WPM
=
Points
1291.0
-0.28
361.5
1291.0 -0.28
361.5
V
EnergyGauge® DCA Form 60OA-2004 EnergyGauge®/FlaRES'2004 FLRCSB v4.0
FORM 60OA-2004 L EnergyGauge® 4.0
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
I ADDRESS: , , , PERMIT #: I
BASE
AS -BUILT
Winter Base Points:
3993.5
Winter As -Built Points:
7364.1
Total Winter X System =
Heating
Total X Cap
X Duct X System X
Credit
= Heating
Points Multiplier
Points
Component Ratio
Multiplier Multiplier
Multiplier
Points
(System - Points)
(DM x DSM xAHU)
lays 1: Electric Heat Pump 27000 btuh .EFF(7.2) Ducts:Unc(S),Unc(R),Gar(AH),R6.0
7364.1 1.000
(1.078 x 1.160 x 1.00) 0.474
1.000
4365.1
'3993:5 ^0:6274 "
- "- "2505.5-
7364.1 `" - 1.00""_.
1.250"-"" 0,474- "
1.000-'
4365:1"
EnergyGaugeTM DCA Form 60OA-2004 EnergyGauge®/FlaRES'2004 FLRCSB v4.0
FORM 60OA-2004 EnergyGauge® 4.0
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
BASE
AS -BUILT
WATER HEATING
Number of X Multiplier
= Total
Tank EF
Number of X Tank X Multiplier X
Credit = Total
Bedrooms
Volume
Bedrooms Ratio
Multiplier
3 2460.00
7380.0
40.0 0.92
3 1.00 2460.00
1.00 7380.0
As -Built Total•
7380.0
CODE
COMPLIANCE
STATUS
BASE
AS -BUILT
Cooling + Heating +
Points Points
Hot Water
Points
= Total
Points
Cooling
Points
+ Heating + Hot Water = Total
Points Points Points
10139 2506
7380
20024
8134
4365 7380 19880
PASS
EnergyGauge*'^ DCA Form 600A.2004 EnergyGaugeftFlaRES'2004 FLRCSB v4.0
FORM 60OA-2004 EnergyGauge® 4.0
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS:.. , PERMIT #:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION REQUIREMENTS FOR EACH PRACTICE CHECK
Exterior Windows & Doors
606.1.ABC.1.1 Maximum:.3 cfm/sq.ft. window area:.5 cfm/sq.ft. door area.
Exterior & Adjacent Walls
606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall:
foundation & wall sole or sill plate; joints between exterior wall panels at corners: utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from, and is sealed to, the foundation to the top plate.
Floors
606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss orjoint members.
EXCEPTION: Frame floors where a continuous Infiltration barrier Is installed that Is sealed
to the perimeter, penetrations_and seams..
Ceilings
606.1.ABC.1.23 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate:
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
Installed that is sealed at the perimeter, at penetrations and seams.
Recessed Lighting Fixtures
606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed: or Type IC or non -IC rated, installed inside a
sealed box with 1 /2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Mufti -story Houses
606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
bA-2L V 1 HtK 1'Kt5l:KH- I IVA: IVItA,UKtb (must De Illet or eXCeeae0 Dy all residences.
COMPONENTS
SECTION
REQUIREMENTS CHECK
Water Heaters
612.1
Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked circuit
breaker (electric) or cutoff (gas) must be provided. External or built -In heat trap required.
Swimming Pools & Spas
612.1
Spas & heated pools must have covers (except solar heated). Noncommercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficiency of 78%.
Shower heads
612.1
Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems
610.1
All ducts. fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
607.1
Separate readily accessible manual or automatic thermostat for each system.
Insulation
604.1, 602.1
Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
EnergyGaugeTM DCA Form 6MA-2004 EnergyGauge®/FlaRES'2004 FLRCSB v4.0
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORNLANCE SCORE' = 83.9
The higher the score, the more efficient the home.
Y
1. New construction or evatin_
New
2. Single family or umlti-tinnay
Single family
3. Number of units, ifualti-fauiily
1
d. Nnmher of Bedrooms
3
5. Is this a worst case?
Yes
6. Conditioned lhxr area (fi')
1291 it'
7. Glass type I and area: (LaWl reyd.
by 13-144.d.5 if n6t defaidt)'
a. U-factor:
Description Area
(or Single or Double DEFAULT)
7a. (Sngle Def vio 1(57.() W
b. SHGC:
(or Clear or Tint DEFAULT)
7b. (Clear) 167.0 fi'
S. Flav types
a. Slab -On -Grade Edge Insulation
R=o.0. 174.((p) it
b.NA
c. NA
9. Wall byes
a. Concrete. Lit lwail. Exterior
R=4.1. 940.0 fl'
b. Frame. W.xvL Adjacent
R=1 L0.1_460 W
c. NA
d. NA
e. NA
lit. Ceiling types
a. Under Attic
R=19.0, 1346.0 fF
b.NA
c. NA
11. Ducts
1-1. Coailing scstenns
a. Central Unit
b. N A
c. NA
13. Heating s�stenis
a. Electric Heat Pump
b. N A
c. NA
_ ld. Hot water sistems
a. Electric Resistance
a. Sap: Uuc. Ret Line AR Garage Sup. R=6.0. 120.0 fi _
b. NA
b. NA
c. Conservation credits
(HR-Heat recoven'. Solar
DHP-Dedicated heat pmnp)
li. HVAC credits
(CF-Ceiling fan. CV -Cross ventilation,
HF-Whole house hm.
PT -Programmable Thermostat.
NE-C-Multizone cooline.
W-H-Multiwne heatin^-)
I certify- that this home has complied with the Florida Euergc Efficiencc Code For Building
Construction through the above energy saving feature clf will be installed (or exceeded)
in this home before final ' rslse on. Otherwise. a Hess E Displac Cud still be completed
based on installed Co a omplian rf �re .
Builder Signature: Date:
Address of New Home: City/FL Zip:
I
* OTE: The home's estinmted is onll• m•ailahle tlnorrgh the FLU RES conrputerl»ograur.
This isl not a Building Enei p Roling. 11'rour score is 80 or greater (oi- 86•/br a (.::S EE4 DOE Ener, :S9mlt designotion).
roar hbnre mqr gnaliJi :J)r ener; r eJJiciencr ruor� <n>c IEE1 D incentives iJl oil obtain a Florida Enersn <iauge Katin >.
Contact the E+crvv Gauge Hotline at 321 63.4-1492 orsee the Euer rt' Gauge ireh sire tit uvvt y'rec.ucJ:edu Jiu
- in)i>rnurtian and a list c�fcerliJied Raters•. For inliuvnoli<»+ about Florida's Enery>r E>jicierrcr Code For• Buildiu,
<'onstruction• contact the Depormrenr off onuntnrin Affiyir•s at 850 487-1824.
Cap: 3o.0 kBtt Ir
SEER 13.00
Cap: _7 1 kBtu lu
HSPF: 7.20
Cap: 40.0 gallons
EF: 0.92
1 Ptndouiinaut glass type. For actual glass type and area.. sa Sumner OR Ranter Glass output on pages 2 4
Ener } G Huge F• ( Version: FLRCKB c4.0)
Summary Energy Code Results
Residential Whole Building Performance Method A
Project Title: Class 3 Rating
New Project LOURAN / SUSANA 11 1291 Registration No. 0
Climate: Central
11 /23/2005
Building Loads
Base
As -Built
Summer:
23766 points
Summer:
24808 points
Winter:
3993 points
Winter:
7364 points
Hot Water:
6790 points
Hot Water: 6790 points
Total:
34549 points
Total:
38961 points
Energy Use
Base
As -Built
Cooling:
10139 points
Cooling:
8134 points
Heating:
2506 points
Heating:
4365 points
Hot Water:
7380 points
Hot Water: 7380 points
Total:
20024 points
Total:
19880 points
PASS
e-Ratio: 0.99
EnergyGauge®(Version: FLRCSB v4.0)
FEB-9-200E, 04:27A FROM:T.D.STFR AIC INC. 7723364171 TO:3365845 P.1
Project Summary;
Enure House er:
TRACY D STEELE A/C INC.
2750 SW EWARCE ST.. PORT ST LUCIE. FL 34853 Phone: $36.2448 Fax 33S4171
For. MONTALTO SUSANNA 129013.0 SEER H.P.
PORT ST LUCIE. FL
Notes:
Weather. Fort Pierce, FL, US
- . Winter Design Conditions
Outside db 42 OF
Inside db 70 OF
Design TD 28 OF
Heating Summary
Structure
21376
Stuh
Central vent (36 cfm)
1104
Btuh
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
26429
Btuh
Infiltration
Method
Simplified
Construction quality
Average
Fireplaces
0
He 12u
Co 1 In9
Area (fly
Volume (le)
11770
11770
Air changesihour
OA5
0.10
Equiv. AVF (cfm)
88
20
Summer Design
Outside db
Inside db
Design TD
Daffy range
Relative humidity
Moisture difference
Sensible Cooling
Duct re
ts
Central vent (90 dm)
Blower
Use manufadurets data
Ratelswing multiplier
Equipment sensible load
Latent Cooling Equipm
Structure
Duda
Central vent t90 cfm)
Equipment latent load
Equipment total load
Req. total capacity at 0.70 SHR
Heating Equipment Summary Cooling Equipment
Make Goodman M Make Goodman Mfgg.
Trade Janitrol GMT Franklin, Goodman, Amana, Evdf t� Jankrcl GMC, Franklin,
Model CPLT361' Cond CPLT3b 1'
Coil ARUFO32-00 -I*
Efficiency
8 HSPF
Efficiency
Heating Input
Sensible cooling
Heating output
30000 Btuh @ 47'F
Latent cooling
Temperature rise
28 OF
Total cooling
Actual air flow
987 cfm
Actual air flow
Air flow factor
0.038 dmlBtuh
Air flow factor
Static pressure
0.00 in H2O
Static pressure
Space thermostat
load sensible heat ratio
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
ma`s WYl WeOVdRO= teW~1 fl012RSR27474
C:tE¢rJu�lteodlApWOmdMyOmmmuIWAOMmM1 HVACVAONTALTO SUSIwDL472B013.OHP.,ry CnY-
90 OF
75 OF
15 OF
L
61 gr/lb
Load Sizing
858 Stuh
631 Btuh
484 Btuh
0 Btuh
Btuh
Sizing
Btuh
Btuh
Btuh
ton
Amana, EverSter.
2000-FW0814=54
Page 1
j
FEB-9-2006-r 04:27A FRDM:T.D.STEELE A/C INC. 7723364171
Component Constructions
Entire House
TRACY D STEELE A/C INC.
27E0 SW EDOARCE ST., PORT ST LUCIE. FL 3403 PhOM 330.2440 Fax 3364171
For.
FL, US
25 it
27°N
Wind speed
MONTALTO SUSANNA 129013.0 SEER H.P.
PORT ST LUCIE, FL
TO:3365845
Job:
Date:
By:
Indoor. H
Indoor temperature (OF)
Design TO ("F)
Relative humidity (%)
Heating Cooling
Moisture difference (grfib)
42 90
Infiltration:
- - 15.-(-L)
_.Method- - . - S
78
Construction quality A
16.0 7.5
Fireplaces 0
P.2
Cooling
75
15
50
61.6
Construction descriptions:
Or
Area
U-valua IMUI R
HIt�g AH,�TM
CID HTM
Gala
UP)
(Buddit"n
IA4'Franml
\--'• M
MUM"
(ah"
Malls
13A-5ocs: Above grade open core concrete block, sldlnptu=,
n
1280
0.125
5.0
3S0
180
2.22
2848
R-5 board Insulation, no farming
Partitions
12B-0bw: Wood stud frame, brick veneer, no board insulation,
98
0.097
11.0
2.72
261
0.85
82
R-11 cavity Insulation
Windows
IA -clam: Operable, metal frame, no break, dear Glass, 1 pans; l
n
16
1270
0.0
35.6
34.8
558
D overhang
a
25
1270
0.0
35.8
26
91.1
2369
5
7
1270
OA
35.6
49
34.8
243
W
24
1270
OA
35.6
853
91.1
2187
all
73
1.270
0.0
35.6
98
73.4
5356
1Aclam: Operable, metal frame, no break, dear glass. 1pane;
a
42
1.270
OA
35.6
94
61.8
2597
100% blinds 46, medium; I R overhang
1Aetom: Operable, metal frame, no break, c(eargl2sa, t pane;
w
32
1270
0.0
35.8
138
61.8
1919
100%blinds 45% medium; 2 D overhang
Doom
11100 Metal door, polystyrene core, vAh storm
n
39
0210
0.0
5.88
229
6.09
238
Ceilings
168-199d: Calling under warded e01G no radiant barrier, dark
1289
0.049
19.0
1.37
769
2.57
3316
shingles, R-19 Insulation
Floors
22A-vph: Vmyl covered slab on grade, heavy moist soil, No edge
176
1.358
0.0
38.0
92
0.00
0
insul, No horiz Insul
I
wrfgFTtSUft Rr2h"UII6Ra8Wert111a0.22RBR27474
2006Feb08
14:60:64
C.%adu*'seo=1 paehronNy D=rwu4VIVoh= HVACWONTALTO SUBANNA IM 13.0 HP.rrp Cek-
Pop
FEB-9-2000� 04:27A FRDM:T.D.STEFLE A/C INC. 7723364171 T0:3365895 P.3
Entire House 1289 25326 2329D 967 967
Other equip loads 1104 1484
Equip. @ 0.96 RSM 18997
Latent cooling 8302
TOTALS 1289 1 26429 27299 967 967
Printout certified by ACCA to meet all requirements of Manual J 8th Ed
wnghtsoft R10*,3Lib Reel0en0el6.o.22RS1W4?4
c:WSW+pliecmepeNlbnWyOmmenMW�011flroI1 MVACVAMALTO SUSANNA 129013.0MPnp Glow
2008•F041814:68:50
Page 2
FEB:9-200E- 04:27A FROM: T. D. STER E A/C INC. 7723354171 TO:3365845 P.4
Job:
Short Form Date:
Entire House ay:
TRACY D STEELE A/C INC.
2750 GWEDGARCE 67r., PORT STLUCIE, FL 340.5 RW .338.2443 FW..33U171
For:
MONTALTO SUSANNA 129013.0 SEER H.P.
PORT ST LUCIE, FL
11
Design
Information
Htg Clg
Infiltration
Outside db (°F)
42 90
Method
m
Inside db'(OF)
70 75
Construction quality
Design TO (°F)
28 15
Fireplaces
Daily range
- L
Inside humidity (%)
50
-
Moisture difference (grilb) 61
HEATING EQUIPMENT
COOLING EQUIPM
T
Make Goodman Mfg.
Make Goodman Mfg.
Trade Janitrol, GMC, Franklin, Goodman, Amana, Ever=rpde Janitrol, GMC, Franklin,
oodman, Amana, EverStar,
Model CPLT30-1•
Cond CPLT3D-1•
Coil ARUFO32-OD•-1•
Efficiency
8 HSPF
Efficiency
138
R
Heating Input
Sensible cooling
20
0
Btuh
Heating output
30000 Btuh @ 47°F
Latent cooling
0
Btuh
Temperature rise
28 OF
Total cooling
2
00
Stuh
Actual air flow
987 Cfm
Actual air flow
7
cfm
Air flow factor
0.D38 dmlBtuh
Air flow factor
O
2
cfm/Btuh
Static pressure
0.00 in H2O
Static pressure
0
in H2O
Space thermostat
Load sensible heat ratio
7a
ROOM NAME
Area
Htg load
Clg load
HIS AVF
CIg AVF
(ftl)
(Btuh)
(Stuh)
(dm)
(Cfm)
M.BED
204
4089
4988
156
207
BED 2
143
3139
2847
120
118
BED 3
143
3139
1696
120
70
G.BATH
40
544
214
21
9
KITCHEN
120
1660
1658
63
69
LIVING
247
4822
4944
184
205
DINING
10a
2747
4864
105
202
M. BATH
70
1985
664
76
28
MISC. HALLS
100
163
275
a
11
WIC 1
42
1579
649
60
27
LAUN.
72
1458
490
58
20
Printout Codified by ACCA to meet all requirements of Manual J 8th Ed.
&wnghtsoft RI0ht- 1 RaWanW6.02211SR2r474
C'.%UWPmaana P10omwy Oauaa•ftVVrl~ WACWONTALTO SLIM w 12001MO r1PAP Calc-
i
2008*048 u:5&04
Pop t