HomeMy WebLinkAboutREVISION - BUILDING PERMITOFFICE USE ONLY: q
DATE FILED: / �a lm
REVISION FEE:
PERMIT # —mod ' D--0L('X�X/
RECEIPT # 157 �,V
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
SCANNED FORT PIERCENFL 349 2- 652
BY (772)462.1553
St. LUCI@ COUII�Ij
APrP�LICATION FOR BUILDING PERMIT RE
PROJECT INFORMATION 4
CONTRACTOR INFORMATION:
STATE of FL REG./CERT,
BUSINESS NAME:
QUALIFIERS NAME
ADDRESS:
CITY:
PHONE (DAYTIME): _
3
STATE:
OWNER/BUILDER INFORMATION:
NAME:
CITY:
PHONE
ARCIIITECT/ENGINEER INFORMATION:
I► 1181 C
CITY:
PHONE(DA
SLCCC: 9123109
Revised 06/30/17
ST. LUCIE CO CERT. #:
W"F
FAX:
ZIP:
ZIP:
ZIP:
m
w
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation -,Residential Performance Method
Project Name: FRAN BISHOP
Builder Name: � BISHOP HOMES, LLC.
Streekl 3608 GROVE COURT
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE. FL,
Permit Number:
Omer.
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County. - St. Lucie (Florida Climate Zone 2 )
1. New construction or e>asting
Now (From Plans)
9. Wall Types (1876.0 sgft.)
Insulation Area
a. Concrete Block- Polystyreneft Bead Aggre2=0.0 1661.30 '
2. Single family or multiple family
Single-family
b. Frame- Wood, Adjacent
R=13.0 214.671N
3. Number of units, if multiple family
1
c. NIA
R= fP
4. Number of Bedrooms
2
d. NIA
10. Ceiling Types (1890.0 sgft.)
R= fN
Insulation Area
5. Is this a worst case?
No
a. Roof Deck (Unvented)
R=21.0 1890.00 R2
6. Conditioned floor area above grade (ftJ
1890
b. N/A
R= ft'
c. NIA
R= ft'
Conditioned floor area below grade (M
0
11. Ducts
R ft'
7. Windows(230.0 sgfL) Description
Area
a. Sup: Attic, Ret Attic, AH: AHU CLST
6 140
a. U-Factor. Slit, U=0.65
230.00 ft'
SHGC: SHGC=0.25
12. Cooling systems
kBtulhr Efficiency
b. U-Factor: N/A
a. Central Unit
35.0 SEER:16.00
SHGC:
c. U-Factor. NIA
ft
SHGC:
13. Heating systems
kBtulhr Efficiency
d. U-Factor. WA
fta.
Electric Strip Heat
27.0 COPA.00
SHGC:
Area Weighted Average Overhang Depth:
7.913 ft.
Area Weighted Average SHGC:
0.250
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor�Types (1890.0 sqft.)
Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation
R=0.0 1890.00 ft'
b. Conservation features
b. NIA
R= ft
None
c. NIA
R= ft'
15. Credits
None
Total Proposed Modified Loads: 61.41
PASS
Glass/Floor Area: 0.12z
Total Baseline
Loads: '61.86
I hereby certify that the plans and specifications covered by
Review of the plans and
0�4Hfi ftJz>
this calculation are in compliance with the Florida Energy
specifications covered by this
OR
4
Code.
calculation indicates compliance
y yi, c
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
A2
DATE: 11 - -
this building will be inspected for
compliance with Section 553.908
.
• ° a
hereby certify that this IldinAllig
nc nce
Florida Statutes.
_with the Florida En gy ode.
cop WE
OWNER/AGE
BUILDINdOFFICIAL:
DATE:
DATE:
ufacturer that the air handler enclosure qualifies as
Checklist in accordance with R402.4.1.1 and this project requires
ter than 7.00 ACH50 (R402.4.1.2).
4 O3 VA
-File, Copy
2017 FBC 6th Edition (2017) Compliant Software
Page 1 of 6
FORM R405-2017 IIVI'C!-i :JUMIYIAMT VPICI+RLI0I RCrIJRI
PROJECT
Title:
FRAN BISHOP
Bedrooms: 2
Address Type:
Street Address
Building Type:
User
Conditioned Area: , 1890
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
BISHOP HOMES; LLC.
Rotate Angle: 0
Street
3608 GROVE COURT
Permit Once:
ST LUCIE COUNTY
Cross Ventilation: No
County.
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: . No
City, State, Zip:
FORT PIERCE,
FamtlyType:
Single-family
FL,
New/Ebsfing:
New (From Plans)
Comment:
CLIMATE
Design Location
TMY Site
Design Temp
97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
1890
17766
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1
MASTER BEDROO
299
2810.6 No
0
1
1
Yes
Yes
Yes
2-
M WIC
72
676.8 No
0
1
Yes
Yes
Yes
3
M BATH
152
1428.8 No
0
1
Yes
Yes
Yes
4
WIC
48
451.2 No
0
1
Yes
Yes
Yes
5
BEDROOM 2
180
1692 No
0
1
1
Yes
Yes
Yes
6
M TOILET
18
169.2 No
0
1
No
Yes
Yes
7
BATH 2
56
526.4 No
0
1
No
Yes
Yes
8
LAUNDRY
70
658 No
0
1
No
Yes
Yes
9
AHU CLST
20
188 No
0
1
Yes
Yes
Yes
10
STUDY
180
1692 No
0
1
Yes
Yes
Yes
11
HALL
72
676.8 No
0
11
No
Yes
Yes
12
STUDY CLST
6
56.4 No
0
1
No
Yes,
Yes
13
LINEN
21
197.4 No
A
1
No
Yes
Yes
14
KITCHEN
241
2265.4 Yes
0
1
Yes
Yes
Yes
15
GREAT ROOM
273
2566.2 No
0
1
Yes
Yes
Yes
16
.DINING
182
1710.8 No
0
1
Yes
Yes
Yes
FLOORS
#
Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation MASTER BEDRO 43 ft 0
299 ft
--
1 0
0
2SIab-0o'-Grade Edge Insulation M WIC 9 ft 0
72 ft
_�
1 0
0
11/7/2019 5:23 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
cnonn oenr; onw IIdDI .. �1 IMMARV CI4FCKI IST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
3 Slab -On -Grade Edge Insulation
M BATH
16 ft
0
152 ft'
—
1
0
0
4 Slab -On -Grade Edge Insulation
WIC
61t
0
48 ft'
--
1
0
0
5 Slab -On -Grade Edge Insulation
BEDROOM 2
14 ft
0
180 ft'
__
1
0.
0
6 Slab -On -Grade Edge Insulation
M TOILET
1 ft
0
18 ft
—
1
0
0
7 Slab -On -Grade Edge Insulation
BATH 2
1 ft
0
56 ft
--
1
0
0
8 Slab -On -Grade Edge Insulation
LAUNDRY
1 ft
0
70 IF
—
1
0
0
9 Slab -On -Grade Edge Insulation
AHU CLST
4 ft
0
20 ft
—
1
0
0
10SIab-On-Grade Edge Insulation
STUDY
22ft
0
180 ft'
_—
1
0
0
11Slab-On-Grade Edge Insulation
HALL
1 ft
0
72 fY
--
1
0
0
12SIab-On-Grade Edge Insulation
STUDY CLST
1 ft
0
6 fP
--
1
0
0
13SIab-On-Grade Edge Insulation
LINEN
1 ft
0
21 W
--
1
0
0
14SIab-On-Grade Edge Insulation
KITCHEN
25 tl
0
241 W
—
1
0
0
15SIab-On-Grade Edge Insulation
GREAT ROOM
11.9 ft
0
273 ft?
--.
1
0
0
16Siab-On-Grade Edge Insulation
DINING
27ft
0
182 fY
--
1
0
0
ROOF
Roof
Gable
Roof
Red
Solar SA Emttt
Emitt
Deck
Pitch
# Type Materials
Area
Area
Color
Bart
Atisor.. Tested
Tested
Insul.
(deg)
1 Hip
Metal 21141P
0 fP
Light
N
0.1 No 6.9
No
21
26.6
ATTIC
/
V
# Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
-
1 Full attic
Unvented
0
1890 ft'
N N
I lf7/2019 5:23 PM EnergyGauge9) USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
u•nr.. ar 1eeenAOV f`UPPtfI 1ST RFP[ART
FUKM K4Ub-ZUII u�ra... avro•■u�•�.
..••��•��•�
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Unvented) MASTER BEDRO 0
Blown
299 ft2
0.1
Wood
_
2
Under Attic (Unvented) MWIC
0
Blown
72 ft2
0.1
Wood
_
_
3
Under Attic (Unvented) M BATH
0
Blown
152 ft2
0.1
Wood "
4
Under Attic (Unvented) - WIC
0
Blown
48 ft2
0.1
Wood
_
5
Under Attic (Unwanted) BEDROOM
0
Blown
1801t'
0.1
Wood
_
6
Under Attic (Unvented) M TOILET
0
Blown
18 ft2
0.1
Wood
_
7
Under Attic (Unvented) BATH 2
0
Blown
561?
0.1
Wood
_
8
Under Attic (Unvented) LAUNDRY
0
Blown
70 ft2
0.1
Wood
_
9
Under Attic (Unvented) AHU CLST
0
Blown
20 ft2
0.1
Wood
_
_
10
Under Attic (Unvented) STUDY
0
Blown
180 ft2
0.1
Wood
11
Under Attic (Unvented) HALL
0
Blown
72 ft2
0.1
Weal
_
12
Under Attic (Unvented) STUDY CLST
0
Blown
6.N'
0.1
Wood
_
_
13
Under Attic (Unvented) LINEN
0
Blown
21 ft2
'0.1
Wood
_
14
Under Attic (Unvented) KITCHEN
0
Blown
2411112
0.1
Wood
15
Under Attic (Unvented) GREAT ROOM
0
Blown
273 ft2
0.1
Wood
_
16
Under Attic (Unvented) DINING
0
Blown
182 ft2
0.1
Wood
WALLS
Adjacent
Cavity
Width Height
Sheathing
Framing
Solar Below
0
Space
_ 1
E
Exterior Concrete Block - PolystyTER BE
0
17
0 9
4
158.7 ft2
0
0
0.1
0
_ 2
W
Exterior Concrete Block - Polysty&WTER BE
0
12
0 9
4
112.0 ft'
0
0 _
0.1
0
3
N
Exterior Concrete Block - PolystyMWTER BE
0
14
0 9
4
130.7 ft2
0
0
0.1
0
_
4
E
Exterior Concrete Block- PolystyrervM WIC
0
9
0 9
4
84.0dP
0
0
0.1
0
_ 5
E
Exterior Concrete Block - Polystyrerld BATH
0
16
0 9
4
149.3 ft2
0
0
0.1
0
6
E
Exterior Concrete Block - PoystyrenANIC 2
0
6
0 9.
4
56.0 ft2
0
0
0.1
0
7
E
Exterior Concrete Block - PolystyMPROOM 2
0
14
0 9
4
130.7 ft2
0
0
0.1
0
8
W
Exterior Concrete Black - Polystyr"U CLST
0
4
0 9
4
37.3 ft2
0
0
0.1
0
9
S
Exterior Concrete Block- PolystyrenSTUDY
0
7
0 9
4
65.3 ft2
0
0
0.1
0
_ 10.
W
Exterior Concrete Block - PolystyrenSTUDY
0
15
0 9
4
140.0 ft2
0
0
0.1
0
_ 11
S
Exterior Concrete Block- PolystyreK&TCHEN
0
a
0 9
4
74.71t2
0
0
0.1
0
_ 12
W
Exterior Concrete Black - PolystyreKATCHEN
0
17
0 9
4
158.7 ft2
0
0
0.1
0
-13'
N
Exterior Concrete Block-PoystyOREAT ROO
0
12
0 9
4
112.0 ft2:
0
0
0.1
0
_ 141
W
Exterior Concrete Block - Polystyrer@INING
0
14
0 9
4
130.7 ft2
0
0
0.1
0
_ 15
N
Exterior Concrete Black- Polystyrer@INING
0
13
0 , 9
4
121.3 ft2
0
0
0.1
0
16,
S
Garage Frame - Woad LAUNDRY
13
23
9
4
214.7 ft2
0
0.1
0.1
0
DOORS
#
Omt Door Type Space
Storms
U-Value
Width
Height Area
Ft
In
Ft
In
1
W Insulated KITCHEN
None
.22
3
8
24 ft2
11/712019 5:23 PM EnergyGaugeD USA 6.0.02,(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
rwrot'}.1 �11 IRRRMADV c41F!_tll. I_CT RFPART
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
# Omt ID Frame
Panes
NFRC
U-Factor SHGC Imp Area
Overhang
Depth Separation
Int Shade
Screening
1 W 2 Metal
_ 2 N 3 Metal
_ 3 E 5 Metal
_ 4 E 7 Metal
_ 5 S 9 Metal
_ 6 W 12 Metal
_ 7 W 12 Metal
_ 8 N 13 Metal
9 N 15 Metal
, Low-E Single
Low-E Single
Low-E Single
Low-E Single
'Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0.65 0.25 Y 24.0 ft'
0.65 0.25 Y 36.0 fY
0.65 0.25 Y 18.0 ft'
0.65 0.25 Y 18.0 W
0.65 0.26 Y 18.0 ft2
0.65 0.25 Y 8.0 ft-
0.65 0.25 Y 8.0 ft2
0.65 0.25 Y 64.0 ft-
0.65 0.25 Y 36.0 ft'
12 ft 0 in 1 It 4 in
2 ft 0 in 1 ft 4 in
2 ft 0 in 1 ft 4 in
2 ft 0 in 1 ft 4 in
6 tt 0 in 1 ft 4 in
2It0 in 1 ft 4 in
8 ft 0 in 1 it 4 in
12 ft 0 in 1 ft 4 in
12ft 0 in 1 ft 4 in
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 575 ft'
576 ft"
23 ft
9 ft
13
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA
.ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000418
2072.7 113.79 214
.1545
7
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Strip Heat/
None
C0P:1
27 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Single SEER: 16 35 kBlu/hr 1050 cfrn
0.8 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric
None
Garage
0.98 50 gal 62.3 gal
120 deg
None.
SOLAR HOT WATER SYSTEM
FSEC -
Cart# Company Name
Collector
System Model# Collector Model# Area
Storage
Volume
FEF
None None
ft2
11/7/2019 5:23 PM EnergyGauge® USA 6.0.02 (Rev. 1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
r.rroi_i„ -rxr 111AMADV rU=nLC1 1_CT RFPART
FUKM K4U0-ZU"I /
caa+nn.v+ . .. — — — —
DUCTS
' —Supply—
—Return—
Air
CFM 25
CFM25
HVAC#
# Location R-Value Area
Location
Area
Leakage
Type
Handler
TOT
OUT ON RLF
Heat Cod
1 Attic
6 140 ft'
Attic
13 ft'
Default Leakage
AHU CLST (Default) c(Default) c
1 1
_
TEMPERATURES
Programable(Thermostat:
Fans:Cooling
CApr
lan )('N
Feb
rX'
[[[ ]]
f[eiling
iMay0(
May
[
Juunn
ItXJul
Jul
1rX
(IX
r t[)C')
Oct
Nov
(rX'� Dee
Dees
Venting [ ] Jahn [ ]
Feb
OCj Mar
[x] Vr
[
[
[
[ Aug
[ Sepov
[X]
[ ]
Thermostat Schedule: HERS 2006 Reference
Hours '
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD)
80
80
80
80
78
78
78
78
78 78
78
78
PM
Cooling (WEH)
PM
80
80
78
78
78
78
78 78
78
78
80
80
78
Heating (WD)
68
68
68
68
65 68
68
68
68
68 68
68
68
PM
Heating (WEH)
68
68
65
68
68
68
68
68
68 68
68
68
PM
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Dafault(8 Ibs/sq.ft.
0 ft'
Oft
0.3
MASTER BEDROO
Default(8 lbs/sq.ft.
ft,
0.3
M WIC
DefauB(8 Ibs/sq.ft.
ff
ft
0.3
M BATH
Default(8 lbs/sq.ft.
ft'
ft
0.3
WIG
Default(8 lbslsq.ft.
fN
ft
0.3
BEDROOM 2
iDefaull(8 lbs/sq.ft.
ft'
ft
0.3
M TOILET
IDefault(8 lbs/sq.ft.
f?
ft
0.3
BATH 2
Defaull(81bs/sq.ft.
fP
ft
0.3
LAUNDRY
iDefault(8 lbs/sq.ft.
ft,
0.3
AHU CLST
Default(81bs/sq.ft.
ft'
ft
0.3
STUDY
Default(8.lbslsq.ft.
fe
ft
0.3
HALL
Default(8 lbs/sq.ft.
ft'
ft
0.3
STUDYCLST
Default(8 Ibs/sq.ft.
ft'
ft
0.3
LINEN
Default(8 lbs/sq.ft.
fN
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
fP
ft
0.3
GREAT ROOM
Default B Ibs/s .ft.
ft-
ft
0.3
DINING
1 V7/2019 5:23 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, Iodation & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family
2. Sincle-famtly
b) Return ducts R 6.0
AHU CLST
c) AHU location
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 2
13. Cooling system: Capacity 35.0
a) Split system SEER 16.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1890
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 0.650
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250
c) Area 7c. 230.0
S. Skylights
a) U-factor.(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 0.0
10131. 13.0
10B2.
11 a. 0.0
11 b.
11 c.
11d. No
14. Heating system: Capacity 27.0
a) Split system heat pump HSPF
b) Single package heat pump,HSPF
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.98
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
t) Heat recovery unit HeatRec%
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
b) Cross ventilation No
c) Whole house fan No
d) Multizone cooling credit
e) Multizone heating credit
0 Programmable thermostat' No
`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise; a new EPL
display card will be completed based on installed code compliant features.
Builder
Address of New Home: 3608 GROVE COURT City/FL Zip: FORT PIERCE FL
1 V7I2019 5:23:24 PMEnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
OFFICE USE ONLY:
DATE FILED: / - jq. ) q
REVISION FEE: a7r• 0
LOCATION/SITE
PERMIT # o y
RECEIPT #
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 341112"FILE
(772)462.1553
APPLICATION FOR BUILDING PE R100NON
RET
PROJECT INFORMATION
DETAILED DESCRIPTION OF PROJECT
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #:
BUSINESS NAME:
QUALIFIERS NAME:
ADDRESS:
CITY:
PHONE (DAYTIME):
STATE:
OWNERBUILDER INFORMATION:
NAME:
CITY:
PHONE
CITY: I" - SKATE:
PHONE (DAYTIME):
SLCCC: 9123109
Revised 06130/17
ST. LUCIE CO CERT. #:
FAX:
F.
FAX:
ZIP:
ZIP:
ZIP:
APR 19 2019
Permitting Department
St. Lucie County, FL