Loading...
HomeMy WebLinkAboutTRUSS PAPERWORKCREEK*' Certificate of Authorization No. 29824 1~.�I 11~�LI iK' 17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, Br" EDITION Manufacturer: TAMKO BUILDING PRODUCTS 220 West a Street Joplin, MO 64801 (417)624-6644 Manufacturing Plants: Joplin, MO KS Frederick, srederick,MID Tuscaloosa, AL Quality Assurance: UL LLC (QUA9625) SCOPE Issued September25, 2017 SC q�jftPhillipsburg, Sy St LUCie C01�i•.6' Category: Roofing Subcategory: Asphalt Shingles Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1. 1523.6.5.1 Properties: Physical properties, Wind Resistance, Wind Driven Rain REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) TAP-043-02-01 TAS 000 1995 PRI Construction Materials Technologies (TST5878) TAP-051-02.01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-054-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-114-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-117.02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-130-02-01 TAS 100 1995 PRI Construction Matedals Technologies (TST5878) TAP-131.02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-165-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5678) TAP-280-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-303-02.01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-307-02.01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-314-02-01 Rev 2 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)el PRI Construction Materials Technologies (TST5878) TAP-317-02-01 TAS 100 1995 UL LLC (TST9628) 02NK9507 ASTM D 3161 2016 UL LLC (TST9628) 04NK24366 ASTM D 3462 201 OA UL LLC (TST9628) 05NK28006 ASTM D 6381 2008(2013)el UL 2390 UL LLC (TST9628) OGNK03898 ASTM D 3161 2016 ASTM D 3462 201 CA UL LLC (TST9628) OSCA59132 ASTM D 3161 2016 UL LLC (TST9628) 09NK07896 ASTM D 3161 2016 ASTM D 3462 201 OA UL LLC (TST9628) IOCA50498 ASTM D 3462 201 CA UL LLC (TST9628) 10CA64882 ASTM D 3161 2016 UL LLC (TST9628) I INK14014 ASTM D 3161 2016 ASTM D 3462 UL LLC (TST9628) 12CA24551 ASTM D 3161 2016A UL LLC (TST9628) 4786110543 ASTM D 6381 2008(2013)el UL LLC(TST9628) 4787043752 ASTM D 3161 2016 UL LLC (TST9628) 4787148748 ASTM D 7158 2011 ASTM D 3161 2016 ASTM D 3462 2010A CREEK Technical Services LLC (ANE11669) TBP15001.3 Calculations 2017 TBP15001.4 1`1-18355-R4 page 1 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CL� E Ei! TAMKO BUILDING PRODUCTS IS G I1 Asphalt Shingles TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION Elite Glass -Seal® 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick, Joplin & asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass -Seal 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H, self-sealing, 3-tab (Frederick & asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass -Seal 12-1/4' x 36", ASTM D 7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass (Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. HerltageO 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas, Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Joplin, Phillipsburg & complying with ASTM D 3462. Tuscaloosa) Heritage®Premium 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas, Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Phillipsburg & complying with ASTM D 3462. Tuscaloosa) Heritage® Premium 12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Frederick) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage® Vintage® 17-1/2" x 40", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage® Woodgate 13-1/4" x 39-3/8', ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas & Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage®Woodgate 12' x 36-3/8", ASTM D 3161, Class'F fiberglass reinforced, laminated architectural (Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Hip and Ridge Shingles 12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt (Frederick & Joplin) shingle surfaced with mineral granules complying with ASTM D 3462. Vintage® Hip and Ridge 12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle (Phillipsburg) surfaced with mineral granules complying with ASTM D 3462. TBP15001.4 FL18355-R4 Page 2 of 11 This evaluation report is provided for Slate of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor Imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC INSTALLATION Elite Glass -Seal® Basic Wind Speed (Vuv): (Frederick, Joplin & Basic Wind Speed (Vwd) Tuscaloosa) Deck (HVHZ): Glass -Seal (Frederick, Joplin (Non- HVHZ) & Tuscaloosa) Deck (Non-HVHZ): Underlayment: Min. slope: Installation (HVHZ): Installation (Non-HVHZ) TSP15001.4 TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or woad plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or woad plank for new construction; Min. 7116 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC. requirements. Refer to the manufacturer's application instructions when Installing shingles at slopes greater than 21:12. Installed with 5-1/8 Inch exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 5-1/8-inch exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. Figure 1. Elite Glass -Seal & Glass -Seal 4 Nail Pattern (Non-HVHZ only) �Flo I19 Figure 2. Elite Glass -Seal & Glass -Seal 6 Nail Pattern R i-1/8" 3 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G203. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This, evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC Heritage® (Dallas, Frederick; Joplin, Phillipsburg & Tuscaloosa) Heritage® Premium (Dallas, Frederick Phillipsburg & Tuscaloosa) Heritage®Woodgate (Dallas & Frederick) Basic Wind Speed (Vuo: Basic Wind Speed (Vasa): Deck(HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation (HVHZ): Installation (Non-HVHZ): TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installed with 5-5/8 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 5-5/8 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nall Pattern" or "6 Nall Pattern" detailed below. NAIL ZONE :ORN EXPOSURE 5-5/8" 1 — 12-112"--+— 12-3/8" —+— 12-1/21I - Figure 3. Heritage®, Heritage® Premium, and Heritage® Woodgate (Dallas) 4 Nail Pattern (non-HVHZ only) FASTENER NAILZONE �LL� COMMON BOND EXPOSURE 5-5/8" 1 � �1-i-1/2'i�l- i-1/2"-►� 7�/8'� 7-12"�-7-1/2"-►� If-1 " Figure 4. Heritage® & Heritage® Premium 6 Nail Pattern TBP15001.4 FL18355-R4 Page 4 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G203. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, Installation, recommended use, or other product a8dbules that are not specifically addressed herein. WCREEK TECHNICAL SERVICES, LLC E 7-i 1a-4 �4-1/2:+7-1/2'Lo 7-318+-1/2+7-1/22� �-1" Figure 5. Heritage® Woodgate 6 Nail Pattern TAMKO BUILDING PRODUCTS Asphalt Shingles M Common Bond 0 s Figure 6. Heritage®, Heritage® Premium, & Heritage® Woodgate Alternate 6 Nail Pattern LOCATION E Figure 7. Heritage® (Tuscaloosa) Expanded Nail Zone Nall patterns from Figures 3, 4, and 6 may be placed in the nail zone as described above TBP15001.4 5355-R4 5 of 11 Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC Heritage® Premium Basic Wind Speed (V„ o): (Frederick) Basic Wind Speed (V,Q: Deck(HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation (HVHZ): Installation (Nan-HVHZ): TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 160 mph In accordance with FBC requirements; Solidly sheathed min. 19132 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7116 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when Installing shingles at slopes greater than 21:12. . Installed with 5 in. exposure in accordance with RAS 116 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. NAIL ZONEf COMMON BOND 1 11"— ►�-- 12" ►�-11n� �in Figure 8. Heritage® Premium (Frederick) 4 Nail Pattern (non-HVHZ only) FASTENERS 51/2" 5" NAIL ZONE/ COMMON BOND 1 u�l �.gt�n r 9°—►�3" 91/zn Ii--1" -I Figure 9. Heritage® Premium (Frederick) 6 Nail Pattern TBP15001.4 FL18355-R4_ Page 6 of 11 This evaluation report Is provided for Slate of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC Heritage® Woodgate Basic Wind Speed (Volt): (Frederick) Basic Wind Speed (V.� ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation (Non-HVHZ): TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in..OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published Installation instructions. Shingles shall be attached using either'4 Nail Pattern" or "6 Nail Pattern" detailed below. BOND EXPOSURE W 1'� �•— 11"-•►�12-3/S"�r- 11e --� �,1" Figure 10. Heritage® Woodgate (Frederick) 4 Nail Pattern (non-HVHZ only) BOND T � &1/2" FEXPOSURE511 1 t 1"� �- 8-1/2" " I' _'�83/8"�3'+►� 8.1/2" ••►I �" Figure 11. Heritage® Woodgate (Frederick) 6 Nail Pattern TBP15001.4 FL1e355-R4 Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this repot is valid. This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not specifically addressed herein. _ CREEK TECHNICAL SERVICES, LLC Heritage® Vintage® Basic Wind Speed (Vmi): (Phillipsburg) Basic Wind Speed (Vasd): Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation (HVHZ): Installation (Non-HVHZ): TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published Installation instructions. Shingles shall be attached using either "5 Nail Pattern" or "6 Nail Pattern" detailed below. rW:aM r th Figure 12. Heritage® Vintage@ 5 Nail Pattern (non-HVHZ only) Figure 13. Heritage@ Vintage® 6 Nail Pattern FL18355-R4 8 of 11 Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC Hip & Ridge Basic Wind Speed (VWi): (Frederick & Joplin) Basic Wind Speed (V,Q: Deck(HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation: TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 In. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15132 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Installed with 5-1/8 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. Direction of prevailing wind exposure Figure 1 Fastener Figure 2 Figure 14. Hip & Ridge (Frederick & Joplin) TBP15001.4 FL18355-R4 axposure I nis evawauon report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK tiIIIIIIIIIIIII TECHNICAL SERVICES, LLC Vintage® Hip & Ridge Basic Wind Speed (Vml): (Phillipsburg) Basic Wind Speed (Vase): Deck(HVHZ): Deck (Nan-HVHZ): Underlayment: Min. slope: Installation: TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBCrequirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15132 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7116 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Installed with 5 inch exposure in accordance with the FBC and manufacturer's published installation Instructions. The direction of the exposed end shall be away from the prevailing wind. Direction of prevailing wind ♦��G�G����! •,�;y,L;t \ 1" "I -Fastener Figure 2 rryure o Figure 16. Vintage® Hip & Ridge (Phillipsburg) TSP15001.4 FL18355-R4 Page 10 of 11 This evaluation report is provided for Slate of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC LIMITATIONS TAMKO BUILDING PRODUCTS Asphalt Shingles 1) Fire Classification is not within the scope of this evaluation. 2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and In accordance with FBC requirements. 3) The mean roof height shall be restricted to a maximum 33 ft In the HVHZ. 4) Classification to ASTM D 7158 applies to exposure B & C with a building mean roof height of 60-ft or less. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) Shingles shall be installed starting at the save in horizontal layers such that the laps shed water from the deck. 7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and code compliant detail shall prevail. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6"' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. R. OAP' R., 2017.09.25 No 74021 11:31:41 a-04'00' 9 STATE OAF` •�� O q 1 p P,: �2�: Zachary R. Priest, P.E. ''1SS..... Florida Registration No. 1 �ONA� E 0 Organization zation No. AN El CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will It acquire, a financial Interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, RE, does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial Interest in any other entity Involved In the approval process of the product. TBP15001.4 END OF REPORT FL18355-R4 I nls evawaoon report Is provloeo for State of Florida product approval under Rule 61 G20.3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not specifically addressed herein.