Loading...
HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSh ENGINEERING & TESTING, INC. Phone: (866) 781-6889 •Fax: (866) 784-8550 RECEIVED irmm.ftoridaenginceringandtesting.com 250 S.W.13"' Avenue �� DEC 2 6 2018 Pompano Beach, FL 33069 DATE: 12/18/18 ST. Lucie County, Permitti B ORDER #• 18-5690 CLIENT: All Area Roofing ADDRESS: 3921 S. US Highway 1 Fort Pierce, Florida 34982 PROJECT: Hood Residence 5V Crimp 26ga. Steel Roof Panels ADDRESS: 906 Coral Street Fort Pierce, Florida S 2017 FBC/ASCE-7 DESIGN PRESSURE CALCULATIONS0 !�4%��,�FO Proiect Information: CMG Mean Height = 9' Exposure: C Basic/Ultimate Wind Speed: Vmt=170 m15�r Length = 58' Category: lI Nominal Wind Speed: V,d=V"it*40.6 Width = 37' Slope: 4/12 = 18' (asd = allowable strength design) Parapet Wall: N/A Residential KZ = 0.85, Kzt =1.0, Kd = 0.85 Design Calculations: Velocity Pressure: q = 0.00256*KzKZtKdV2 Velocity Pressure (uit): q=0.00256(0.85)(1.0)(0.85)(170)2] = 53.45 psf Velocity Pressure (0d): q=0.00256(0.85)(1.0)(0.85)(170*40.6)2] = 32.07 psf Width of Pressure Coefficient: Effective Wind Area: <1 OfO External Pressure Coefficient: 1) GCP1 = -0.9 2) GCP2 = -1.7 3) GCP3 = -2.6 0.1(3T) = 3.7' 0.4(9') = 3.6' ) use: 4'0" Design Pressures Based on V"5d: Internal Pressure Coefficient: 1) GCPi = 0.18 1) Field PI = 32.07*[(-0.9) — (0.18)] = -34.6 psf 2) Perimeter P2 = 32.07*[(-1.7) — (0.18)] = -60.3 psf 3) Corners P3 = 32.07* [(-2.6) — (0.18)] = -89.2 psf 1r �1 0 '� 'vi Quality 1�13,` A�V./lssnrance Page 2, 12/18/18, Job Ors__ : 48-5690 All Area Roofing - Hood Residence 5V Crimp 26ga. Steel Roof Panels Hood Residence; Fort Pierce, FL: Attachment Requirements: DEC 26 2018 ST. Lucie County, Based on the requirements of Florida Product Approval # 11651.12 with maximum design pressures of-108.5psf (for 12" o.c. fastener row spacing); the following are our recommended fastening patterns to attach the 24" wide 5V Crimp 26 ga. Steel Roof Panels to the min. 15/32" thick, APA Rated plywood deck (attached to structural supports per product approval) with # 9-15xl.5" fasteners with sealing washing through panel rib with a 1/4" minimum penetration through plywood: Area Field, Perimeter & Corner (Method 2) Design Pressure -108.5psf Fastener Pattern @ Panel Ribs (12" o.c.) Fastener Pattern (Row) Spacing 12" o.c. Fastener # 9-15x1.5" fasteners with sealing washing through panel rib with a 1/4" minimum penetration through plywood Notes: Corners and perimeter (edge, hip, & ridge) area dimension shall not be less than a = 4'0" (Zone 2: Perimeter (including along ridges) is a 410" wide strip, Zone 3: Corners are 4'0" x 4'0") Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2017 Edition. Wind load calculations based on ASCE-7, 2017 FBC, and information provided by client. Client is responsible for verifying existing conditions as it pertains to the above provided product approval. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. Sincerely, `.N a pLAN Mark A. Mesiat(2�P.E. Florida Engin& TsvtjpjbF nc. Florida Reg. No- Q2,� �Q� Certificate of ZU%I r'�,�3�ILq { \��