Loading...
HomeMy WebLinkAboutD O H PAPERWORK (2)JAN 0 0 2019 PERMIT #: 56-SF-1891227 STATE OF FLORIDA ���� COICATION :AP1372800 DEPARTMENT OF HEALTH DATE PAID: ONSITE SEWAGE TREATMENT AND DISPOSAL FEE PAID: SYSTEM RECEIPT #: RECEIVED #: PR1193724 DEC 2 6 2018 CONSTRUCTION PERMIT FOR: OSTDS New SCANNED APPLICANT: Yoan and Ta mi Rojas . Lucie County, Permitting BY PROPERTY ADDRESS: TBD Briltain Ave Fort Pierce, FL 34945 util LOT: 1, 2, 3, 10, 11, an BLOCK: A SUBDIVISION: PROPERTY ID #: 2310-801-0001-000-4 [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] [OR TAX ID NUMBER] SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY. SYSTEM DESIGN AND SPECIFICATIONS T [ 900 ] GALLONS / GPD Septic CAPACITY A [ 1 GALLONS / GPD NIA CAPACITY N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] K [ ] GALLONS DOSING TANK CAPACITY E ]GALLONS @[ ]DOSES PER 24 RRS #Pumps E D [ 375 ] SQUARE FEET R [ 1 SQUARE FEET A TYPE SYSTEM: [ ] I CONFIGURATION: Ex] N F LOCATION OF BENCHMARK: SYSTEM N/A SYSTEM STANDARD E 1 FILLED EX] MOUND TRENCH [ ] BED E 1 NED CL of Briltain Ave W property line extended S I ELEVATION OF PROPOSED SYSTEM SITE E BOTTOM OF DRAINFIELD TO BE L D I 0 T H E R E 10.001E INCHES FT ][ABOVE kBELOW'ji BENCHMARK/REFERENCE POINT E 7.00 1E INCHES FT ][ABOVE BELOW BENCHMARK/REFERENCE POINT ie system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 0 9pd. e licensed contractor installing the system is responsible for installing the minimum category of tank in accordance with 64E-6.013(3)(f), FAC. SPECIFICATIONS BY: Brian J Ingra TITLE: Environmental Specialist APPROVED BY: LE: Environmental Specialist II Brian J Ingr _ DATE ISSUED: 12/06/201$ EXPIRATION DATE: DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC II St. Lucie CHD 06/06/2020 Page 1 of 3 v 1.1.4 AB1372800 SE1143536 NOTICE OF RIGHTS A party whose substantial interest is affected by this order may petition for an administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for administrative hearing must be in writing and must be received by the Agency Clerk for the Department, within twenty-one (21) days from the receipt of this order. The address of the Agency Clerk is 4052 Bald Cypress Way, BIN A-02, Tallahassee, Florida 32399. The Agency Clerk's facsimile number is 850-413-8743. Mediation is not available as an alternative remedy. Your failure to submit a petition for hearing within 21 days from receipt of this order will constitute a waiver of your right to an administrative hearing, and this order shall become a'final order'. Should this order become a final order, a party who is adversely affected by it is entitled to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a second copy, accompanied by the filing fees required by law, with the Court of Appeal in the appropriate District Court. The notice must be filed within 30 days of rendition of the final order. 'a�'i r dW HEALTH PAYING ON: .RECEIVED FROM: PAYMENT FORM: St. Lucie County Health Department 5150 NW Milner Dr Port Saint Lucie, FL 34983 PERMIT M 56-SF-1891227 GILL Doc #:56-BID-4015256 CONSTRUCTION APPLICATION H: AP1372800 Trefelner Construcion Inc. AMOUNT PAID: $ 515.00 CHECK 1672 PAYMENT DATE: 11/09/2018 MAIL TO: Yoan and Taymi Rojas FACILITY NAME: PROPERTY LOCATION: TBD Brittain Ave Fort Pierce, FL 34945 Lot: 1. 2, 3. 10, 11, and 12 Block: A Property ID: 2310-801-0001-000-4 EXPLANATION or DESCRIPTION: 128 - OSTDS Construction System Inspection Research Fee -1 - Surcharge (All) -1 - OSTDS New Permit Surcharge -1 - OSTDS Construction Application and Plan Review,New 123 - OSTDS Construction Site Evaluation 126 - OSTDS Construction Permit (New or Mod, Amendment) 127 - OSTDS Construction System Inspection 133 - OSTDS Construction Reinspection QUANTITY FEE 1 $ 5.00 1 $ 15.00 1 $ 100.00 1 $ 100.00 1 $ 115.00 1 $ 55.00 1 $ 75.00 1 $ 50.00 RECEIVED BY: MontanezNM AUDIT CONTROL NO. 56-PID-3791134 �r+a4 STATE OF FLORIDA 2, DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM APPLICATION FOR CONSTRUCTION PERMIT APPLICATION FOR: PERMIT NO. . ^t W 1 DATE PAID: II 01 19) FEE PAID: CV-# I(D-1a RECEIPT #: 404CO [� ] New System [ ] Existing System [ ] Holding Tank [ ] Innovative [ ] Repair [ ] Abandonment [ ] Temporary [ ] APPLICANT: Yoan and Taymi Rojas AGENT: James Trefelner TELEPHONE:772-201-9833 MAILING ADDRESS: 1760 Copenhaver Road Fort Pierce, Florida 34945 TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED BY A PERSON LICENSED PURSUANT TO 489.105(3)(m) OR 489.552, FLORIDA STATUTES. IT IS THE APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS. PROPERTY INFORMATION LOT: 1,2,3,1h BLOCK: A SUBDIVISION: Doiran PROPERTY ID #: 2310-801-0001-000-4 PLATTED: ZONING: AR-1 I/M OR EQUIVALENT: [ No ] PROPERTY SIZE: 2.54 ACRES WATER SUPPLY: [ ] PRIVATE PUBLIC [ ]G=2000GPD [,/]>2000GPD IS SEWER AVAILABLE AS PER 381.0065, FS? [ No ] DISTANCE TO SEWER: FT PROPERTY ADDRESS: BrittainAve -; 4gg5 DIRECTIONS TO PROPERTY: seeattached BUILDING INFORMATION Unit Type of No Establishment 1 residence 2 3 4 [ ✓ ] RESIDENTIAL [ ] COMMERCIAL No. of Building Commercial/Institutional System Design Bedrooms Area Sqft Table 1, Chapter 64E-6, FAC 3 2321 [ ] Floor/Equipment Drains [ ,/ ] Other (Specify) Garbage grinders/ Disposals SIGNATURE: NO DH 4015, 08/0 e(Obsoletes pre i,oUs editions which may not be used) Incorporated 64E-6.001, FAC DATE: 11/7/2018 Page 1 of 4 STATE OF FLORIDA APPLICATION # AP1372800 DEPARTMENT OF HEALTH PERMIT # 56-SF-1891227 ONSITE SEWAGE TREATMENT, AND DISPOSAL SYSTEM DOCUMENT # SE1143536 SITE EVALUATION AND SYSTEM SPECIFICATION APPLICANT: Yoan and Taymi Rojas CONTRACTOR / AGENT: Trefelner Construcion Inc. LOT: 1, 2. 3. 10. 11. and 12 BLOCK: A SUBDIVISION: Doiran ID#: 2310-801-0001-000-4 TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. ENGINEERS MUST PROVIDE PROPERTY SIZE CONFORMS TO SITE PLAN: Ex ]YES [ ]NO NET USABLE AREA AVAILABLE: 2.54 ACRES TOTAL ESTIMATED SEWAGE FLOW: 300 GALLONS PER DAY [ RESIDENCES -TABLET / OTHER -TABLE 2 ] AUTHORIZED SEWAGE FLOW: 6349.98 GALLONS PER DAY [ 1500 GPD/ACRE OR 2500 GPD/ACRE ] UNOBSTRUCTED AREA AVAILABLE: 1008.00 SQFT UNOBSTRUCTED AREA REQUIRED: 750.00 SQFT BENCHMARK./REFERENCE POINT LOCATxON: NO CL of Brittain Ave W property line extended S ELEVATION OF PROPOSED SYSTEM SITE 10.00 [[INCHES / FT ] [ ABOVE / BELOW BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: FT DITCHES/SWALES: 40 FT NORMALLY WET: [ ]YES [X]NO WELLS: PUBLIC: FT LIMITED USE: FT PRIVATE: FT NON -POTABLE: FT BUILDING FOUNDATIONS: 5 FT PROPERTY LINES: 40 FT POTABLE WATER LINES: 10 FT SITE SUBJECT TO FREQUENT FLOODING? [ ]YES [X]NO 10 YEAR FLOODING? [ ]YES [X]NO] 10 YEAR FLOOD ELEVATION FOR SITE: FT [ MSL / NGVD ] SITE ELEVATION: FT [ MSL / NGVD SOIL PROFILE INFORMATION SITE 1 SOIL PROFILE INFORMATION SITE 2 USDA SOIL SERIES:Pineda sand Munsell #/Color Texture Depth 1 OYR 4/2 Sand 0 To 12 10YR 6/1 Sand 12 To 19 1 OYR 6/1 Sand 19 To 25 1 OYR 6/1 Gravelly & Larger Mineral 25 To 48 10YR 4/3 Sand 25 To 48 1 OYR 5/2 Sandy Clay Loam 48 To 55 10YR 5/1 Sandy Clay Loam 55 To 61 10YR 5/1 Loamy Sand 61 To 67 10YR 5/2 Sand 67 To 72 USDA SOIL SERIES:Pineda sand Munsell #/Color Texture Depth 10YR 4/2 Sand 0 To 12 1 OYR 5/2 Loamy Sand 12 To 25 7.5YR 5/8 CMN/PRM RF 21 To 30 1 OYR 6/1 Sand 25 To 28 1 OYR 6/2 Sand 28 To 48 2.5Y 5/2 Sandy Clay Loam 48 To 63 2.5Y 5/1 Loamy Sand 63 To 72 OBSERVED WATER TABLE: 69.00 INCHES [ ABOVE / BELOW ] EXISTING GRADE TYPE: [ PERCHED / APPARENT ] ESTIMATED WET SEASON WATER TABLE ELEVATION: 21 INCHES [ ABOVE / DELOW ] EXISTING GRADE HIGH WATER TABLE VEGETATION: [ ]YES [X]NO MOTTLING: EX ]YES [ ]NO DEPTH: 21.00 INCHES SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: Sand/0.80 DEPTH OF EXCAVATION: 49 INCHES DRAINFIELD CONFIGURATION: [X] TRENCH [ ] BED [ ] OTHER (SPECIFY) r REMARKS/ADDITIONAL CRITERIA VT determined using USDA WSS and soil borings. R5I8 CMN PROM RF mottling in IOYR5/2 and 10YR6/1 matrix>2% starting at 21" in SB2. 9" below BM. SB210" below RM. /7 SITE EVALUATED BY: Ingram, Brian (Title: Envi (�i (mental Specialist II) (ENVIRONMENTAL HEALTH) DH 4015, 08109 (Obsoletes previous editions which may not be used) Incorporated: 64E 6.001, PAC DATE: 11/16/2018 Page 3 of 4 AP1372800 EID1891227 v 1.0.2 APPLIC UNT'S LEGAL ,QosA 5�•sF_ ��q�2z� I certify that there are no potable private wells within 75 feet of the available area for the proposed septic system, that there are no non -potable wells within 50 feet of the available area for the proposed septic system, that there are no wells within 25 feet of a pesticide -treated building foundation, that there are no public wells that serve less than 25 people or less than 15 homes or businesses within 100 feet of the proposed septic system, that there are no public wells that serve more than 25 people or more than 15 homes or businesses within 200 feet of the proposed septic system, that the water line from the water meter or well to the structure is at least 10 feet from the available area for the proposed septic system unless the plans show the line to be double sleeved, that there is not a gravity sewer line, low pressure sewer line or vacuum sewage line in a public easement or right -of --way that abuts the property, that there are no lakes, streams, wetlands, or surface water within 75 feet of the available area for the proposed septic system unless the property was created prior to 1972, that the septic system is proposed on the side of the lot farthest from surface water, that all private wells, septic systems and surface water on adjacent or contiguous land within 75 feet of the applicant's lot are shown on the site plan, that all public wells within 200 feet of the applicant's lot are shown on the site plan, and that the location of building or residences, swimming pools, recorded easements, paved areas or driveways, sidewalks, the general slope of the property, filled areas, drainage features, and surface waters such as lakes, ponds, streams, canals, or wetlands are shown on the applicants lot. The natural grade elevation in the area of the proposed septic system and the benchmark must be shown on the site plan. Please locate the benchmark within 200 feet of the proposed septic system. NOTE: MUST BE CERTIFIED BY A FLORIDA REGISTERED SURVEYOR OR ENGINEER. �.Kf(�rtit4'SCIIIIC¢$COIIC:1j1�1jIP::_ull] CERTIFIED BY: FLORIDA y PROFESSIONAL NO.: _ DATE:%"'Z•-' ,R 10BNO.:\