Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2017 /P /2, - o ysy FILE COPY FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION 6orida Department of Business and Professional Regulation - Residential Performance Method CT1/cry SCANNED Project Name: BEEBE RESIDENCE uilder Name: TREFELNER CONSTRUCTION Street CODYLANE DEC 262018 ermit Office: STLUCIECOUNTY BY City, State, Zip: FORT PIERCE, FL, F emit Number: St, Lucie Count}9 Owner: JUSTIN AND CHELSE, B E J :�pIpFE1Nl1" PBrITIFhih risdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce -- ounty: St. Lucie (Florida Climate Zone 2 ) 1. Newlconstruction or existing New (From Plans) 9. Wall Types (1810.7 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Ext Insul, Exterior R=4.1 1810.70 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (1768.0 sgft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 1768.00 ft2 6. Conditioned floor area above grade (ft2) 1768 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(228.0 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: LAUNDRY RM 6 140 a. U-iFactor: SgI, U=0.32 156.00 ft2 SHGC: SHGC=0.22 b. U-Factor: Sgl, U=0.40 72.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 29A SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: AreaiWeighted Average Overhang Depth: 2.000 ft. ArealWeighted Average SHGC: 0.229 14. Hot water systems a. Propane Tankless Cap: 1 gallons B. Floor Types (1768.0 sqft.) Insulation Area EF: 0.590 a. Slab -On -Grade Edge Insulation R=0.0 1768.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.129 Total Proposed Modified Loads: 60.67 PASS Total Baseline Loads: 65.54 1 hereby certify that the plans and specifications covered by Review of the plans and tHE STgT� this calculation are in gQmpliance with the Florida Energy specifications covered by this �I Code. calculation indicates compliance ti '••• c',•:atYh',;:o. °„ �O. with the Florida Energy Code. hnrp. PREPAREDY Before construction is completed DATE.` this building will be inspected for y compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. CO With the Florida Energy Cade. / O D WEIR � � // OWNER/AGE . BUILDING OFFICIAL: ,T DATE: /o /?i% DATE: " - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 10/31/2018 10:48 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST mr-rvlcr PROJECT Title: BEEBE RESIDENCE Bedrooms: 3 Address Type: Street Address Buildi g Type: User Conditioned Area: 1768 Lot# Owne Name: JUSTIN AND CHELSEA BEE Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: TREFELNER CONSTRUCTI Rotate Angle: 0 Street: CODYLANE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1768 20060 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 3 176 1654.4 No 0 1 1 Yes Yes Yes 2 CLST 3 20 188 No 0 1 Yes Yes Yes 3 BATH 2 60 564 No 0 1 Yes Yes Yes 4 BEDROOM 2 176 1654.4 No 0 1 1 Yes Yes Yes 5 CLST 2 20 188 No 0 1 Yes Yes Yes 6 HALL 24 225.6 No 0 1 No Yes Yes 7 KITCHEN 374 5236 Yes 0 1 Yes Yes Yes 8 FAMILY ROOM 374 5236 No 0 1 Yes Yes Yes 9 MASTER BEDROO 256 2406.4 No 0 1 1 Yes Yes Yes 10 M WIC 66 620.4 No 0 1 No Yes Yes 11 M BATH 131 1231.4 No 0 1 Yes Yes Yes 12 LAUNDRYRM 63 592.2 No 0 1 Yes Yes Yes 13 MTOILET 28 263.2 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 3 26 fl 0 176 ft- __ 1 0 0 2 Slab -On -Grade Edge Insulation CLST 3 2 ft 0 20 ft- ___ 1 0 0 3 Slab -On -Grade Edge Insulation BATH 2 6 ft 0 60 ft' ___ 1 0 0 4 Slab -On -Grade Edge Insulation BEDROOM 2 26 ft 0 176 fe ___ 1 0 0 10/31/2018 10:48 AM EnergyGaugeCDJ USA Section R405.4.1 Compliant Software Page 2 of 6 PnRnn Rdn6-7n17 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulation CLST 2 2 it 0 20 112 ___ 1 0 0 6 Slab -On -Grade Edge Insula8on HALL 1 it 0 24 ft2 1 0 0 7 Slab -On -Grade Edge Insulation KITCHEN 22 it 0 374 ft' ___ 1 0 0 8 Slab -On -Grade Edge Insulation FAMILY ROOM 22 it 0 374 ft' ___ 1 0 0 9 Slab -On -Grade Edge Insulation MASTER BEDRO 32 it 0 256 ft2 --- 1 0 0 10SIab-On-Grade Edge Insulation M WIC 1 it 0 66 112 ___ 1 0 0 11SIab-On-Grade Edge Insulation M BATH 14 It 0 131 ft' ___ 1 0 0 12SIab-On-Grade Edge Insulation LAUNDRY RM 9 It 0 63 ft2 _--_ 1 0 0 13SIab-On-Grade Edge Insulation M TOILET lift 0 28 ft2 __ 1 0 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 1977 ft2 0 ft2 Light 0.6 No 0.9 No 20 26.6 ATTIC v # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1768 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ 1 Under Attic (Unvented) BEDROOM 20 Blown 176 ft' 0.1 Wood _ 2 Under Attic (Unvented) CLST 3 20 Blown 20 ft2 0.1 Wood _ 3 Under Attic (Unvented) BATH 2 20 Blown 60 ft2 0.1 Woad _ 4 Under Attic(Unvented) BEDROOM 20 Blown 176 ft2 0.1 Wood _ 5 Under Attic (Unvented) CLST 2 20 Blown 20 112 0.1 Wood 6 Under Attic (Unvented) HALL 20 Blown 24 11:2 0.1 Wood 7 Under Attic (Unvented) KITCHEN 20 Blown 374 ft' 0.1 Wood 8 Under Attic (Unvented) FAMILYROOM 20 Blown 374 k' 0.1 Wood 9 Under Attic (Unvented) MASTER BEDRO 20 Blown 256 ft2 0.1 Wood 10 Under Attic (Unvented) MWIC 20 Blown 66 112 0.1 Wood 11 Under Attic (Unvented) M BATH 20 Blown 131 ft' 0.1 Wood 12 Under Attic (Unvented) LAUNDRYRM 20 Blown 63 ft2 0.1 Wood 13 Under Attic (Unvented) MTOILET 20 Blown 28 ft2 0.1 Wood 10/31/2018 10:48 AM EnergyGaugeO USA Section R405A.1 Compliant Software Page 3 of 6 POPM R411Fi-9f117 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 1 S EMerior Concrete Block - Ext InstBEDROOM 3 4.1 14 0 9 4 130.7 ft' 0 0 0.6 0 _ 2 W Exterior Concrete Block - Ext InsZEDROOM 3 4.1 12 0 9 4 112.0 ft' 0 0 0.6 0 _ 3 W Exterior Concrete Block - Ext Insul CLST 3 4.1 2 0 9 4 18.7 fN 0 0 0.6 0 4 S Exterior Concrete Block- Ext Insul BATH 2 4.1 6 0 9 4 56.0 ft' 0 0 0.6 0 _ 5 E Exterior Concrete Block - Ext Ins5EDROOM 2 4.1 12 0 9 4 112.0 ft' 0 0 0.6 0 _ 6 S Exterior Concrete Block - Ext InstZEDROOM 2 4.1 14 0 9 4 130.7 ft' 0 0 0.6 0 7 E Exterior Concrete Block - Ext Insul CLST 2 4.1 2 0 9 4 18.7 ft' 0 0 0.6 0 _ 8 W Exterior Concrete Block - Ext Insul KITCHEN 4.1 22 0 14 0 308.0 ft' 0 0 0.6 0 _ 9 E Exterior Concrete Block- Ext InsiAAMILY ROO 4.1 22 0 14 0 308.0 ft' 0 0 0.6 0 _ 10 N Exterior Concrete Block- Ext InstMASTER BE 4.1 16 0 9 4 149.3 W 0 0 0.6 0 _ 11 W Exterior Concrete Block- Ext InstRIASTER BE 4.1 16 0 9 4 149.3 ft' 0 0 0.6 0 _ 12 N Exterior Concrete Block- Ext Insul M BATH 4.1 14 0 9 4 130.7 ft' 0 0 0.6 0 _ 13 E Exterior Concrete Block- Ext InsdIAUNDRY R 4.1 9 0 9 4 84.0 ft' 0 0 0.6 0 _ 14 N Exterior Concrete Block- Ext InsulM TOILET 4.1 4 0 9 4 37.3 ft' 0 0 0.6 0 15 E Exterior Concrete Block- Ext InsulM TOILET 4.1 7 0 9 4 65.3 ft- 0 0 0.6 0 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening _ 1 S 1 Vinyl Low-E Single Yes 0.32 0.22 N 15.0 ft' 2 ft 0 in 1 ft 4 in None None _ 2 W 2 Vinyl Low-E Single Yes 0.32 0.22 N 15.0 ft- 2 ft 0 in 1 ft 4 in. None None 3 S 4 Vinyl Low-E Single Yes 0.32 0.22 N 6.0 ft' 2 ft 0 in 1 ft 4 in None None _ 4 E 5 Vinyl Low-E Single Yes 0.32 0.22 N 15.0 ft' 2 ft 0 in 1 ft 4 in None None _ 5 S 6 Vinyl Low-E Single Yes 0.32 0.22 N 15.0 ft' 2 ft 0 in 1 ft 4 in None None _ 6 W 8 Vinyl Low-E Single Yes 0.32 0.22 N 9.0 ft- 2 ft 0 in 1 ft 4 in None None _ 7 W 8 Vinyl Low-E Single Yes 0.4 0.25 N 48.0 ft' 2 ft 0 in 1 ft 4 in None None 8 E 9 Vinyl Low-E Single Yes 0.32 0.22 N 16.0 ft- 2 ft 0 in 1 ft 4 in None None _ 9 E 9 Vinyl Low-E Single Yes 0.4 0.25 N 24.0 ft' 2 ft 0 in 1 ft 4 in None None 10 N 10 Vinyl Low-E Single Yes 0.32 0.22 N 20.0 ft' 2 ft 0 in 1 ft 4 in None None _ 11 W 11 Vinyl Low-E Single Yes 0.32 0.22 N 15.0 ft' 2 ft 0 in 1 ft 4 in None None _ 12 N 12 Vinyl Low-E Single Yes 0.32 0.22 N 15.0 ft' 2 ft 0 in 1 ft 4 in None None 13 E 13 Vinyl Low-E Single Yes 0.32 0.22 N 15.0 ft' 2 ft 0 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000505 2340.3 128A8 241.63 .4061 7 10/31/2018 10:48 AM EnergyGauge® USA Section R405A.1 Compliant Software Page 4 of 6 r GnRne PAns-9n17 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 29.4 kBtu/hr 882 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Propane Tankless Exterior 0.59 1 gal 55.1 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / —Supply--- —Return-- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 140 ft' Attic 14 ft' Default Leakage LAUNDRY (Default) c(Default) c 1 1 TEMPERATURES ProgramablerxT'Jhermostat:: Cr[eiling Fans: Heating 'JN Jan Feb rx]], Mar �Cj JMay un [ ] Jul jX] [ ] Aug X� 4 ] Sep Oct NovrD0'j[Xj] Nov Dec Venting 11 L 1 Jan 11 Feb L 1 IXl Mar lhl Apr [ May l l Jun 11 Jul 11 Aug 11 Sep [XJ [ ] DDec ec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating'.(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 10/31/2018 10:48 AM EnergyGauge@ USA Section R405A.1 Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space I�IDefault(8 Ibs/sq.@. befault(8 lbs/sq.ft. 0 ft2 ft2 O ft ft 0.3 0.3 M W IC 2 M W IC 1 Default(8 lbs/sq.ft. ft2 ft 0.3 MASTER BATH Default(8 lbs/sq.ft. ft2 ft 0.3 TOILET Default(8 lbs/sq.ft. ft2 ft 0.3 LINEN Default(8 lbs/sq.ft. ft2 ft 0.3 FOYER Default(8 lbs/sq.ft. ft2 ft 0.3 DINING ROOM Default(81bs/sq.ft. ft2 ft 0.3 LIVING ROOM Default(81bs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(81bs/sq.ft. ft2 ft 0.3 UTILITYROOM Defaull(81bs/sq.ft. ft2 ft 0.3 CLST 2 Default(81bs/sq.ft, ft2 ft 0.3 BEDROOM 2 Default(81bs/sq.ft. ft2 ft 0.3 BATH 2 Default(81bs/sq.ft. ft2 ft 0.3 CLST 3 '.Default(81bs/sq.ft. ft2 ft 0.3 NOOK Default(81bs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(81bs/sq.ft. ft2 ft 0.3 WIC CLOSET Default(8 ll ft2 ft 0.3 MASTER BEDROO Name: Signature: 1r Rating Compant: Date: (Q';Hb 10/31/2018 10:48 AM EnergyGauge® USA Section R406A.1 Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE,402 4-" AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: BEEBE RESIDENCE Builder Name: TREFELNER CONSTRUCTION street: CODY LANE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: U Owner: JUSTIN AND CHELSEA BEEBE -. - Jurisdiction: - . ST LUCIE COUNTY W x Design Location: FL, Fort Pierce � COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for franierl walls shall be installed in substantial contact and continuous alignment with the air barrier. M, Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity, insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity, insulation shalli and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottoff to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided Instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped, shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility, penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be out to fit, or narrow Narrow cavities cavifles shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed In the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend be ind i in and— irin . Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electricallphone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover Plates and walls or ceilings. , I U, ,may W011� Juan uc ui eccuwence Wim the provisions or iu:-vuu. 10/31/201810:49 AM EnergyGaugeO USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD �s .•d4li, u.��.:.+ds ..., , t , 1 �1� 5"q.4. F, d� 1 '��'?1'� ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX" = 93 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 29.4 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5.f No b) Single package SEER c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 1768 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.345 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.229 14. Heating system: Capacity 27.0 c) Area 7c. 228.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF 0.59 A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 20.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No `Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: - t/ i Date: 10 Address of New Home: CODY LANE City/FL Zip: FORT PIERCE. FL 10/31/2018 10:49:00 AM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Project Summary Date: Oct 30, 2018 wrightsoft' Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE. FORT FL 34946 Phone: 772466-6799 Fac 772-466-6796 Emil: For. BODY LRESIDENCE THE E WER CONSTRUCTION Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TO 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 20377 Btuh Structure 15875 Btuh Ducts 4609 Btuh Ducts 6482 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24985 Btuh Use manufacturer's data n Rate/swingg multiplier Equipment 0.95 Infiltration sensible load 21239 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2779 Btuh Ducts 1718 Btuh Central vent (0 cfm) 0 Btuh Area Heatingg Cool (none) (ft') 1768 1768 Equipment latent load 4497 Btuh Volume (ft3) 19958 19958 Air changes/hour 0.38 0.20 Equipment Total Load (Seri+Lat) 25737 Btuh Equiv. AVF (cfm) 126 67 Req. total capacity at 0.70 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR40311_1 AHRI ref Coil TEM6AOC36H31++TDR AHRI ref 7567544 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 6.5 kW Sensible cooling 20580 Btuh Heating output 22119 Btuh Latent cooling 8820 Btuh Temperature rise 21 OF Total cooling 29400 Btuh Actual airflow 980 cfm Actual airflow 980 cfm Air flow factor 0.039 cfm/Btuh Air flow factor 0-044 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.83 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed wrlgM1tSOR• 2018-Oct-3011:08:33 �� Rlghl-Suite® Universal 201818.0.31 RSU08101 Page 1 EADocumnets\Wrightsoft HVAC\BEEBE RESIDENCE.rup Calc=MJ8 Front Door faces: E wrightsoft Right-M Worksheet Job: Entire House Date: Oct 30, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCWOL.COM 1 2 3 4 5 Room name 9wpwed wall Room height Room dimensions Room area Entire House 172.0 If 11.3 ft 1768.0 ft- BEDROOM 3 26.0 ft 9.3 It heat/cool 1.0 x 176.0 It 176.0 W Ty Construction number U-wlue (Btuh/fti°F) Or HTM (Bluh/ft') Area (ft) or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Ruh) Heat I Cad Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 Vy- U.143 0.320 0.320 - n n n 4.00 8.96 8.96 -219 9.41 9.41 - 318 20 15 281 0 0 1126 179 134 615 188 141 0 0 0 0 0 0 0 0 0 0 0 0 13A 5a 2 glazing, cir lower 2 glazing, cir laws I�-fGa 11 4y 13A-4= 2 glazing, dr low-e 2 glazing, clr low-e 2 Cimino. cir low_e 13A4om 2glazing cir low,e 2 glazing,cir_lowe_, 13A-4om 2 glazing, cir low-e 2 glazing, cir lows 2 olazino, cir low -a -16A-30md� - 22A-pti 0.143 0.320 0.320 -0.320 0.143 0.320 0.320 0.143 0.320 0.320 0.320 10.032 1.358 a a a e s s _s_ w w w w ,� - 4.00 8.96 8.96 8.96 4.00 896 _8.96 4,00 8.96 8.96 8.96 =0,90 38.02 2.19 24.75 25.20 25.20 " 2..19 9.41 _9.41 2.19 23.96 24.75 25.20 _2.24 0.00 587 30 16 24 -316 6 ___.-_-30 587 9 30 48 =768 1768, 517 4 1 2 2070 269 143 215 1122 54 -269 1131 743 403 605 -613 56 -282 0 0 0 0 130 0 0 0 0 0 115 0 15 0 0 0 0 461 0. - 34 387 0 134 0 , =158 989 0 0 0 0 252 0 41 211 0 371 0 1394 0 ILI--(CG; 280 12 -60 500 2 4 4 1768 172 C^� F 2002 81 269 430 =584 6540 1094 216 743 1209 =3960 0 ___�15 112 0 15 0 176 97 0 1 0 =176 26 176 6 c)AED excursion 128 64 Envelope loss/gain _ 16487 12128 2263 1434 12 a) Infiltration b) Roam ventilation 3890 0 1097 0 521 0 147 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 2650 0 0 0 Subtotal (lines 6 to 13) 20377 15875 2784 1581 14 15 Less eMemal load Less transfer Redistribution Subtotal Duct loads 23% 41% 0 0 0 20377 4609 0 0 0 15875 6482 23% 41% 0 0 118 2902 656 0 0 59 1640 670 Total room load Air required(cfm) 24r 980 72357 980 3558 140 2310 101 Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed c ,`�v�!9hisoTc� 2018-Oct-30 11:08:33 cA ' ^^ RlghtSuiteO Universal 2018 18.0.31 RSU08101 Page 1 E:\Documnets\wfightsoft HVACIBEEBE RESIDENCE.rup Calc = MA Front Door faces: E wrightsoft, Right-J® Worksheet Job: Entire House Date: Oct 30, za,s By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fes 772-466-6796 Emil: OUICKCALCS AOL.COM 1 2 3 4 5 Room name - Eglosed wall Room height Room dimensions Room area CLST 3 2.0 R 9.3 If heat/cool 2.0 x 10.0 ft 20.0 W BATH 2 6.0 ft 9.3 ft heat/cool 10.0 x 6.0 ft 60.0 fN Ty Construction number U-value (BtUhfft�°F) Or HTM (Btuhfft� Area (ftj or perimeter (ft) Load (Btuh) Area (11) or perimeter (ft) Load (BtUh) Halt Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 -6143 0.320 0.320 n n n 4A0 8.96 8.96 2.19 9.41 9.41 0 0 _ 0 0 0 0 0 0 0 -0 0 0 0 -0 0- 0 0 0 0 0 0 0 0 !0 0 0 13Mtocs 2 glazing, clr lmw 2 glazing, Ur 1--a 11 V9/ L��fGG 13A4ocs 2 glazing, clr Iowa 2 glazing, Ur Iowa 2 gl=IM. clr low_e 13A-0ocs _ -' 2 glazing, Ur lowe 2.glazing, cIr lowe„ 2gluins 2 glazing, clr m-eIm-e 2 glazing, Ur lava 2 glazinti. Ur lave _i64-30if1d 22A4 0. 0.320320 0.320 0.320 -0.143 0.320 _0.320 0.320 0.320 0.320 0.320 -0;032 1.358 a a a a s- s ,is_ w w w w - 4.. 8.9696 8.96 8.96 4.00 8.96 _8.96 8.96 8.96 8.96 8.96 „0.90 38.02 24.7575 25.20 25.20 - 2.19 9.41 _9.41 219 24.75 24.75 25.20 ;;2,24 0.00 0 0 0 0 0 0 0 0 0 0 0 - 0 0 0 0 0 0 0 0 • 0 0 0 0 0 0 . 0 199 54 0. 0 0 0 0 -"109 56 4�Il-G !._1i.. 0 0 0 0 0 - 0 0 0 0 0 0 -56 6 0 60 6 0 y/ IIL---IGG' F 19 0 0 0 =20 20 -0 19 0 0 0 =20 2 74 0 0 0 41 0 0 0 0 0 0 0 =60 60 0 0 0 0 =60 6 0 0 0 0 54 228 _._0. 0 0 0 0 _134 0 18 76 45 0 6 c)AED excursion -6 -22 Envelope losstgain 168 79 535 278 12 a) Infiltration b) Room ventilation 40 0 11 0 120 0 34 0 13 Internal gains: Occupants (a] 230 Appliances/other 0 0 0 0 0 0 Subtotal (fines 6to 13) 208 91 655 312 14 15 Less edemal load Less transfer Redistribution Subtotal Duct loads 23% 41% 0 0 -208 0 0 0 0 -91 0 0 23% 41% 0 0 6 662 150 0 0 15 327 134 Total roan load Air required (cfm) 0 0 0 0 811 32 461 20 Calculations approved byACCA to meet all requirements of Manual J 8th Ed w�:Bhbon 2018-Oct-3011:08:33 AECA RlghtSuite® Universal 2018 18.0.31 RSU08101 Page 2 E:\DocumnelsMightsoft HVAC\BEEBE RESIDENCE.rup Calc = 14J8 Front Door faces: E wrightsofC Right-M Worksheet Job: Entire House Date: Oct 30, zo,a By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Faz 772466-6796 Emil: OUICKCALCS@AOL.COM 1 2 3 4 5 Room name Elposed wall Room height Room dimensions Room area BEDROOM 2 26.0 ft 9.3 It heat/cool 1.0 x 176.0 ft 176.0 ft- CLST 2 2.0 ft 9.3 ft heat/cool 2.0 x 10.0 It 20.0 ft' Ty Construction number U-value (BtuwftioF) Or HTM (&Uwftl Area (fP) or perimeter (it) Load (Btuh) Area (ft2) a perimeter (ft) Load (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross I N/P/S Heat Cool 6 13A-05cs 2 glazing,. clr Iowa gglazing, clrlg -6143 0.320 0.320 n- n n 4.00 8.96 8.96 -219 9.41 9.41 0 0 0 0 0 0 0 0 0 --0-0-0-0 0 0 0 0 0 0 0 0 -0 0 0 11 W jL��fG, 13A4ccs 2 glazing, or Io 2 glazing, clr Iou,-e 2 glazing _clr lov e_ 13A46cs 2 glazing, clr Iow-e 2 glazing„dr.lowc_ 134-0ocs 2 glazing, clr lore 2 glazing, Gr Iowa 2 glazing, clr lame 16A�30md 22A4 1311- 0.143 0.320 0.320 0.320 "-0.143 0.320 -0,320 0. 0.320320 0.320 0.320 _0,032 1.358 a a a e s s -sv w w w w _ - 4.00 8.96 8.96 8.96 -4.00 8.96 ,__.-8.96 4.. 8.9696 8.96 8.96 =0.90 38.02 2A9 24.75 25.20 25.20 - 2.19 9.41 _9.41 23.96 24.7575 25.20 =2.24 0.00 112 15 0 0 97 1 0 0 115 0 15 387 134 0 0 461 0 - 34 0 0 0 0 158 211 371 0 0 -252 0 �141 0 0 0 0 �394 0 19 0 0 0 19 0 0 0 74 0 0 0 41 0 0 III-----GGG - 130 0 5 0 0 __0 0 0 0 0 _-20 20 -0 0 -0 0 0. _0 0 0 0 0 0 0 =76 176 0 0 0 0 `176 -0 0 0 0 0 -20 2 0 0 0 0 _,0 0 0 0 0 45 0 _C_ F 18 76 26 989 �u 6 c)AED excursion -115 S Envelope loss/gain 2263 1255 168 79 12 a) Infiltration bj Room ventilation 521 0 147 0 40 0 11 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 250 0 0 0 Subtotal (lines 6 to 13) 2784 1652 208 91 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 23% 41 % 0 0 118 2902 656 0 0 59 1712 699 23% 41% 0 0 -208 0 0 0 0 -91 0 0 Total room lead Air required (cfm) WM 140 2410 1061 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed _ # wrlghesoft- 2018-Oct-3011:08:33 RlghtSuite® Universal 201818.0.31 RSU06101 Page 3 'AE:1Documnets\Wrighlsoft WAC\BEEBE RESIDENCE.rup Cale=MJ8 Front Door faces: E F� wrightsoft, Right-M Worksheet Job: Entire House Date: Oct 30, zo,a By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Emil: OUICKCALCWOL.COM 1 2 3 4 5 Room name E�losad wall Room height Room dimensions Room area HALL 0 It 9.3 ft heat/cod 4.0 x 6.0 ft 24.0 ft2 KITCHEN 22.0 It 14.0 ft heat/cool 22.0 x 17.0 ft 374.0 ft2 Ty Construction number U-value (BtulVfti°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft-) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 4:00 8.96 8.96 y 219'-0 9.41 9.41 -0 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 0.143 0.320 0.320 n n n 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 �C 11 lq/ I-G 13A-0ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 ctlazlna. clr low-e_ cs 2 glazing, clr low-e 2 glazatg„clr,low e_ lak4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazinq, clr lave - 22A-tph _ 0.143 0.320 0.320 0.320 �'-0.143 0.320 _0.320 0.143 0.320 0.320 0.320 �0.032 1.358 a a a e s s _a_ w w w w ` 4.00 8.96 8.96 8.96 4.00 8.96 .._8.96 4.00 8.96 8.96 8.96 =0.90.._ 38.02 2.19 24.75 25.20 25.20 'i 2.19 9.41 _9.41 2.19 23.96 24.75 25.20 2:24 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 a 0 0 0 0 0 0 0 0 0 0 0 IL--(C; _ W613A-4 y/ �G IL-cC' 1 -0 0 0 0 0 0 0 0 0 0 0 0 0 -0 0 0 -0 -0 0 _0 0 0 0 0 =24 �,-0 0 0 0 0 0 0 0 0 -22 0 0 0 0 0 �54 0 308 9 0 48 W 374 374 251 1 0 2 ,� 374 22 1005 81 0 _430 __n5 837 549 216 0 1209 _838 0 ,C N.:16A-30md F, =24 0 24 ,� 6 c)AED excursion 3 513 Envelope loss/gam 22 50 2687 3325 12 a) Infiltration b) Room ventilation 0 0 0 01 663 0 187 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (fines 6to 13) 22 50 3351 3512 14 15 Less e#emal load Less transfer Redistribution Subtotal Duct loads 23% 41 % 0 0 -22 0 0 0 0 -50 0 0 23% 41 % 0 0 98 3449 780 0 0 49 3561 1454 Total room load Air required (cfm) 0 0 0 0 4229 166 5015 220 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. -FWwrlghtsoY!^ 2018-Oct3011:08:33 RightSuile® Universal 2018 18.0.31 RSU08101 Page 4 E:\Documnets\Wrightsoft HVAC\BEEBE RESIDENCE.mp Cato =MJ8 Front Door faces: E wrightsoft Right-M Worksheet Job: Entire House Date: Oct 30, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: OUICKCALCS@,AOL.COM 1 2 3 4 5 Room name F)gmsed wall Room height Room dimensions Room area FAMILYROOM 22.0 ft 14.0 It heat/cool 22.0 x 17.0 ft 374.0 ft' MASTER BEDROOM 32.0 ft 9.3 it heat/cod 16.0 x 16.0 It 256.0 fl' Ty Construction number U-value (Btuh/ft? -F) Or HTM (Btuhlft') Area (ft') or perimeter (ft) Load (Btuh) Area (fN) or perimeter (ft) Load (Stuh) Heat Cool Gross WP/S Heat Cad Gross WP/S Heat Cgol 6 yf I--C 13A-0ocs 2glazing, dr lvx� 2 glazing, cir I- n n n - 4.00 8.96 8.96 219 9.41 9.41 0 0 0 0 0 0 0 0 0 0 0 0 119 20 0 129 0 0 -516 179 0 28-2 188 0 l0.143 0.320 0.320 I-G 11 lql li(--EGG 13A4gcs 2 glazing, cir low-e 2 glazing, clr lower 2 glazinq. ctr Iowa 13A-4ocs- 2 glazing, cir low-e 2 glazing, clr-low:e_ 13A-4ocs 2 glazing, cir low-e 2 glazing, cir Im-e 2 glazing, cir lov-e 164-30mdy 22A-tph 0. 0.320320 0.320 `0.320 0.143 0.320 0.320 0.143 0.320 0.320 0.320 =0.032 1.358 a a a a s s -a- w w w w - 4. 8.9696 8.96 8.96 4.00 8.96 -8.96 4.00 8.96 8.96 8.96 `0.90 38.02 219 24.75 25.20 25.20 _ 2.19 9.41 -9.41 2.19 23.96 24.75 25.20 2.24 0.00 30 0 0 16 24 268 0 1 1 -0 0 0 107 0 0 143 215 0 0 58 0 0 403 605 - 0-0-0-0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 `G. ^ 0 0 _-0 0 0 0 0 =374 374 0 0 0 0 -0 0 0 0 0 0 _____374 22 . 0 0 0 0 `335 8370 0 0 0 0 ;838 149 0 15 0 =256 256 -0 134 0 1 0 _=56 32 536 0 134 0 -229 1217 _0 293 0 371 0 =573 0 C= F 6 c)AED excursion -112 .60 Envelope loss/gam 2603 2320 2811 1647 12 a) Infiltration b) Room ventilation 663 0 187 0 641 0 181 0 13 Internal gains: Occupants Q 230 Appliances/other 0 0 6W 0 0 1400 Subtotal(lines 6to 13) 3266 3107 3452 =8 14 15 Less e#emal lead Less transfer Redistribution Subtotal Duct loads 23% 41% 0 0 98 3364 761 0 0 49 3156 1289 23% 41% 0 0 0 3452 781 0 0 0 3228 1318 Total room load Air required (cfm) 4125 162 4444 195 4233 166 4546 199 Calculations approved byACCA to meet all requirements of Manual J 8th Ed wrlght S. - 2018-Oct-3011:08:33 A& Right -Suite® Universal 201818.0.31 RSUD8101 Page 5 EnDocumnets\Wrightsolt HVAC\BEEBE RESIDENCE.wp Cale =MJ8 Front Door faces: E I wrightsoft° Right-M Worksheet Job: Entire House Date: Oct30, 201e By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name F)posed wall Room height Room dimensions Room area M WIC 0 ft 9.3 ft heat/cool 6.0 x 11.0 ft 66.0 W M BATH 14.0 ft 9.3 ft heat1cool 1.0 x 131.0 It 131.0 ft' Ty Construction number U-value (BtuNftk'F) Or HTM (Btuh/ft') Area (fF) or perimeter (ft) Load (Btuh) Area (fP) or perimeter (ft) Load (Btuh) Heat I Cool Grass WP/S Heat Cool Gross WPIS Heat Cool 6 w I--G 13A4 2 glazing, Gr low-e 2 gluing, clr lowe -0343 0.320 0.320 n In n 4.00 8.96 8_96 -219 9.41 9.41 0 0 0 0 0 0 0 0 0 0 0 0 130 0 15 115 0 0 461 0 124 252 0 _ 141 III------(GGG 11 13A4ocs 2 glazing, dr low-e 2 glazing, cir low-e 2 glminq.,,clr low-0.320 13A-4ocs _ 291azing, clr low- 2 glazing-dr.low:e_ 2gluins 2 glazing, clr Iowa 2 glazing, clr Iowa 2 glazing, clr lg _16M30md 22A-lph 0.143 0.320 0.320 0.143 0.320 _0.320 0.320 0.320 0.320 0.320 =0032 1.358 a a a e s` s -s_ w w w w = - 4.00 8.96 8.96 8.96 4.06 8.96 8,96 8.90 8.96 8.96 8.96 =0.90 38_02 2is 24.75 M20 25.20 - 219 9.41 _R41 3.96 23.75 24.75 25.20 _224 0.00 0 0 0 0 - -0 0 -- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4y - I`-1C' 0 0 0 0 0 0 0 0 0 0 0 0 0 0 V0 0 0. 4y -0 0 0 0 0 �fi6 0 �0 0 0 0 0 =59 0 .r0' 0 0 0 0 _1, 0 0 0 0 0 731 131 ..,_._0 0 0 0 0 =131 14 0 0 0 0 = 117 532 0 0 0 0 =293 0 L��CCC F� =66 66 6 c)AED excunstm -10 -59 Envelope loss/gain 59 138 1245 627 12 a) Innriltratim b) Room ventilation 0 0 0 0 280 0 79 0 13 IMerral gains: Occupants @ 230 Appliances/other 0 0 01 0 0 150 Subtotal (lines 6 to 13) 59 138 1526 856 14 15 Less e#emal load Less transfer Redistribution Subtotal Duct loads 23% 41% 0 0 0 59 13 0 0 0 138 56 23% 41% 0 0 0 1526 345 0 0 0 856 350 Total mom load Air required (cfm) 73 3 195 9 1871 73 1206 53 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed _ wrlgM1Csofl� Riile®Universal207818RSU08101 SAE:\Docuets\Wdghtsoft HVAC1BEEBEEEBE RESIDENCE.mp CaIo= 2018-Oct-3011:08:33 mnMJB Front Door faces: E Page Job +wrightsoft, Right-M Worksheet Date: House Date: OctO30, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM 1 2 3 4 5 Room name E)gmed wall Room height Room dimensions Room area LAUNDRYRM 9.0 ft 9.3 It heaticool 9.0 x 7.0 ft 63.0 ft2 M TOILET 11.0 It 9.3 It heaticool 7.0 x 4.0 It 28.0 ft2 Ty Construction number U-value (Btuh/W "F) Or HTM (BtulUft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross NIP/S Heat Cool Gross NIP/S Heat Cool 6 4�/'- ,-9 _ 13A-0ocs 2 glazing, cir lave 2glazing„clrloiv-e _0343 0.320 0_320 n n d 4 00 8.96 6.96 ��4.00 -2:19 9.41 9,41. - 0 0 0 0 0 0 0 0 0 0 0 0 -37 0 0 -37 0 0 _ f49 0 0 -81 0 0 11 VjI 13A-0acs 2 glazing, clr low-e 2 glazing, cir lower 2 clazuxq cir_Im-e 13A-4ccs ' - 2 glazing w cir lo-e 2 glazing, clr,low;e_ 13A4ocs 2 glazing, cir IIcvvem-e 2glazing, cir low�e 2 glazinp, cir Im-e _16&Wmd 27Mtph 0.143 0.320 0.320 0.320 - 0.143 0.320 _0.320 0.320 0.320 0.320 _,0.320 ___W__0.032 1.358 a a a e_ - s s _a_ w w w w - 8.96 8.96 8.96 4.00 8.96 _,_,.8.96 4.90 8.96 8.96 8.96 =0.96 38.02 2.19 24.75 25.20 25.20 --2.19 9.41 -9.41. 2.96 24.75 24.75 25.20 --224 0.00 84 15 0 0 69 1 0 0 275 134 0 0 ISO 371 0 0 65 0 0 0 65 0 0 0 261 0 0 0 142 0 0 0 �L-GG Wi' I-C 1-G 0 0` 0 0 -0 0 -0 -0 0 0 0; _0 0 _0 0 _0 0 W -0 0 0 0 0 -0 0 0 0 0 0 0 0 0 -0 0 0 0 0 41 0 -0-0-0 0 0 0 0 0 0 0 0 0 0 0 0 =25 418 _0 0 0 0 0 =63 0 C F' 63 =63=-56 =28 28 =28 11 63 9 342 6 c)AED excursion 32 -23 Envelope loss/gain 808 630 853 264 12 a) InfiRmtion b) Room ventilation 180 0 51 0 220 0 62 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 250 0 0 0 Subtotal (lines 6to 13) 988 931 1073 326 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 23% 41% 0 0 0 988 224 0 0 0 931 380 23% 41% 0 0 0 1073 243 0 0 0 326 133 Total room load Air required (cfm) 1212 48 1312 57 1316 52 459 20 Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed wrl9tifsoTC- 2018-Oct3011:08:33 Right -Suite@ Universal 201818.0.31 RSUD8101 Page 7 rADocumnets\Wrightsoll WAC\BEEBE RESIDENCE.mp Calc=MJB Front Door faces: E +� wrightsoft Duct System Summary Date: W30,2018 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: OUICKCALCSa@AOL.COM For. BEEBE RESIDENCE, TREFELNER CONSTRUCTION CODY LANE, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 980 cfm Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 980 cfm 191 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Matt Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 811 32 20 1.000 5.0 OxO VIFx 38.8 115.0 st2 BEDROOM 2 h 3558 140 106 1.000 7.0 OxO VIFx 30.8 115.0 st2 BEDROOM 3 h 3558 140 101 1.000 7.0 0x0 VIFx 52.6 135.0 st4 FAMILY ROOM C 2222 81 97 1.000 7.0 0x0 VIFx 38.1 115.0 st2 FAMILY ROOM -A C 2222 81 97 1.000 7.0 OX0 VIFX 9.7 115.0 st1 KITCHEN c 2507 83 110 1.000 7.0 Ox0 VIFX 55.7 135.0 st4 KITCHEN -A C 2507 83 110 1.000 7.0 Ox0 VIFX 24.4 135.0 st3 LAUNDRY RM C 1312 48 57 1.000 6.0 OxO VIFx 8.0 115.0 st1 M BATH h 1871 73 53 1.000 6.0 Ox0 VIFx 13.0 115.0 st1 M TOILET h 1316 52 20 1.000 5.0 OxO VIFx 16.4 115.0 st1 M WIC C 195 3 9 1.000 4.0 OxO VIFx 25.6 135.0 st3 MASTER BEDROOM C 2273 83 100 1.000 7.0 Ox0 VIFx 24.4 135.0 st3 MASTER BEDROOM�A C 2273 83 100 1.000 7.0 Ox0 VIFx 20.9 135.0 st3 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st4 Peak AVF 222 211 1.000 504 9.0 0 x 0 VinlFlx st2 st2 Peak AVF 475 434 1.000 719 11.0 0 x 0 VinlFlx st3 Peak AVF 252 318 1.000 719 9.0 0 x 0 VtnlFlx st1 st1 Peak AVF 505 546 1.000 695 12.0 0 x 0 VtnlFlx C Wrightsoft- 2018-Oct3011:08:34 W..+..n-+ RightSuite® Universal 2018 18.0.31 RSU08101 Page 1 E:\Documnets\Wrightsoe HVAC\BEEBE RESIDENCE.rup Cale =MJS Front Door faces: E Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL M Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 980 980 0 0 0 0 Ox 0 VIFx -f}i- w_rightsoft- 2018-00-3011:08:34 RighlSuite® Universal 201818.0.31 RSU08101 Page 2 E1Dccu"ets\Wrightsoft WACIBEEBE RESIDENCE.rup Cato =MJB Front Door faces: E