HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 4000 Avenue L
Builder Name:
SCANNED
Street: 4000 Avenue L
Permit office:
City, State, Zip: Ft. Pierce , FL, 34947
Permit Number:
By
Owner: Guilf Dieuvil
Jurisdiction:
County:: St. Lucie Climate
SS}, LUC
Zone 2 )1e County
Design Location: FL, Fort Pierce
(Florida
1. New construction or existing
New (From Plans)
9. Wall Types (1593.0 sqft.)
Insulation Area
a. Frame - Wood, Exterior
R=13.0 1593.00 ft2
2. Single family or multiple family
Single-family
b. N/A
R= ft
3. Number of units, if multiple family
1
c. N/A
R= ft'
4. Number of Bedrooms
4
d. N/A
R= ft
10. Ceiling Types (1450.0 sqft.)
Insulation ' Area
5. Is this a worst case?
No _
a. Under Attic (Vented)
R=38.0 1450.00 ft2
6. Conditioned floor area above grade (ft2)
1450
b. NIA
R= fP
c. N/A
R= ft2
Conditioned floor area below grade (ft2)
0
11. Ducts
R ft2
7. Windows(205.0 sqft.) Description
Area
a. Sup: Attic, Rel: Attic, AH: AC
6 290
a. U-Factor. Sgl, U=0.70
205.00 ft'
SHGC: SHGC=0.50
-
12. Cooling systems
kBEfficiency
b. U-Factor. NIA
ft'
a. Central Unit
36.0 36.0 SEER:14.00
SHGC:
c. U-Factor: NIA
ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. N/A
ft2
a. Electric Strip Heat
27.3 COPA.00
SHGC:
Area Weighted Average Overhang Depth:
0.000 ft.
Area Weighted Average SHGC:
0.500
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1448.0 sqft.)
Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation
R=0.0 1448.00 ft
b. Conservation features
b. WA
R= ft2
None
c. N/A
R= ft'
15, Credits
CF, WHF
Total Proposed Modified Loads: 54.54
PASS
Glass/Floor Area: 0.141
Total Baseline Loads: 54.61
1 hereby certify that the plans and specifications covered by
Review of the plans and
OY'CIiE STgl�
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
/
with the Florida Energy Code.
1. /nru
PREPARED BY: v✓
Before construction is completed
ra
_)�I A.
DATE: /-
9 : 1.a/ 9
this building will be inspected for
compliance with Section 553.908
�
°
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
It yS
COO
with the Florida Energy Code
t'
WE
OWNER/AGENT•
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this roerequires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 42 ; ). E Cj
/ T .(OPY
1/9/2019 12:51 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017
PROJECT
Title:
4000 Avenue L
Bedrooms:
4
Address Type:
Street Address
Buildirig Type:
User
Conditioned Area:
1450
Lot#
Owner'Name:
Guilf Dieuvil
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
Rotate Angle:
0
Street:
4000 Avenue L
Permit Office:
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
Whole House Fan:
Yes
City, State,
Zip:
Ft. Pierce ,
Family Type:
Single-family
FL , 34947
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design
Temp
Heating Design Daily Temp
v Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
1450
13050
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1
Master Bed
189
1701 No
2
1
1
Yes
Yes
Yes
2
Mbath
38
338 No
0
1
Yes
Yes
Yes
3
mclst
28
248 No
0
1
No
Yes
Yes
4
Laundry
91
819 No
0
1
Yes
Yes
Yes
5
Kitchen
99
891 Yes
0
1
Yes
Yes
Yes
6
Living Room
239
2151 No
0
1
Yes
Yes
Yes
7
Hall
84
758 No
0
1
No
Yes
Yes
8
Family Rm
202
1818 No
0
1
Yes
Yes
Yes
9
c
10
90 No
0
1
No
Yes
Yes
10
AC
10
90 No
0
1
No
Yes
Yes
11
Bed 2
127
1143 No
1
1
1
Yes
Yes
Yes
12
c2
17
155 No
0
1
Yes
Yes
Yes
13
Bed 3
138
1242 No
1
1
1
Yes
Yes
Yes
14
03
19
173 No
0
1
Yes
Yes
Yes
15
Bath
43
383 No
0
1
Yes
Yes
Yes
16
Bed 4
94
846 No
1
1
1
Yes
Yes
Yes
17
c4
10
90 No
0
1
Yes
Yes
Yes
18
L
12
108 No
0
1
No
Yes
Yes
1/9/2019 12:51 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2017
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
1 Slab -On -Grade Edge Insulatio
Master Bed
31 ft
0
188.5 ft2
—
1
0
0
2 Slab -On -Grade Edge Insulatio
Mbath
5 ft
0
37.5 ft'
—
1
0
0
3Slab-On-Grade Edge Insulatio
mclst
1 ft
0
27.5 ft'
___
1
0
0
4Slab-On-Grade Edge Insulatio
Laundry
20 ft
0
91 ft'
—
1
0
0
5 Slab -On -Grade Edge Insulatio
Kitchen
11 ft
0
99 ft'
—
1
0
0
6 Slab -On -Grade Edge Insulatio
Living Room
17.5 ft
0
239 ft'
—
1
0
0
7SIab-On-Grade Edge Insulatio
Hall
1 ft
0
84.3 ft'
__
1
0
0
8 Slab -On -Grade Edge Insulatio
Family Rm
20.5 ft
0
201.8 fN
—
1
0
0
98Iab-On-Grade Edge Insulatio
c
1 ft
0
10 ft'
____
1
0
0
10SIab-On-Grade Edge Insulatio
AC
1 ft
0
10 fN
—
1
0
0
11SIab-On-Grade Edge Insulatio
Bed 2
22.5 ft
0
126.5 ft'
—
1
0
0
12SIab-On-Grade Edge Insulatio
c2
2.5 It
0
17.3 ft'
—
1
0
0
13SIab-On-Grade Edge Insulatio
Bed 3
23.5 ft
0
138 ft'
—
1
0
0
14SIab-On-Grade Edge Insulatio
c3
3.5 ft
0
19.3 ft'
__
1
0
0
i
15SIab-On-Grade Edge Insulatio
Bath
5 ft
0
42.5 ft'
—
1
0
0
1631ab-On-Grade Edge Insulatio
Bed 4
11 ft
0
93.5 ft
___
1
0
0
1751ab-On-Grade Edge Insulatio
c4
4 ft
0
10 ft'
—
1
0
0
18SIab-On-Grade Edge Insulatio
L
1 It
0
12.3 ft'
—
1
0
0
ROOF
/
Roof Gable
Roof
Solar
SA Emift
Emitt
Deck
Pitch
V
# Type Materials
Area Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Gable or Shed Composition shingles
1526 ft 240 ft'
Medium
0.9
No 0.9
No
0
18.4
ATTIC
/
V
# Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Vented
300
1448 ft'
N N
1/9/2019 12:51 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2017
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented)
Master Bed
38
Blown
189 ft'
0.1
Wood
_
2
Under Attic (Vented)
Mbalh
38
Blown
38 ft'
0.1
Wood
_
3
Under Attic (Vented)
mclst
38
Blown
28 ft'
0.1
Wood
4
Under Attic (Vented)
Laundry
38
Blown
91 ft'
0.1
Wood
_
5
Under Attic (Vented)
Kitchen
38
Blown
99 ft'
0.1
Wood
6
Under Attic (Vented)
Living Room
38
Blown
239 ft'
0.1
Wood
_
7
Under Attic (Vented)
Hall
38
Blown
84 W
0.1
Wood
_
8
Under Attic (Vented)
Family Rm
38
Blown
202 ft'
0.1
Wood
9
Under Attic (Vented)
c
38
Blown
10 ft'
0.1
Wood
10
Under Attic (Vented)
AC
38
Blown
10 ft'
0.1
Wood
11
Under Attic (Vented)
Bed 2
38
Blown
127 ft'
0.1
Wood
_
12
Under Attic (Vented)
c2
38
Blown
17 ft'
0.1
Wood
_
13
Under Attic (Vented)
Bed 3
38
Blown
138 ft2
0.1
Wood
_
14
Under Attic (Vented)
c3
38
Blown
19 ft'
0.1
Wood
_
15
Under Attic (Vented)
Bath
38
Blown
43 ft2
0.1
Wood
16.
Under Attic (Vented)
Bed 4
38
Blown
94 ft'
0.1
Wood
_
17
Under Attic (Vented)
e4
38
Blown
10 ft2
0.1
Wood
_
18
Under Attic (Vented)
L
38
Blown
12ft'
.1
Wood
WALLS
Adjacent
�
Cavity
Width
Height
Sheathing
Framing
Solar
Below
n,ntSpace
_ 1
E
Exterior Frame - Wood
Master Bed
13
14
6 9
6
130.5 ft'
0
0.25
0.5
0
_21
S
Exterior Frame - Wood
Master Bed
13
13
0 9
0
117.0, ft2
0
0.25
0.5
0
_ 3,
W
Exterior Frame -Wood
Master Bed
13
3
6 9
0
31.5 ft'
0
0.25
0.5
0
_ 4
E
Exterior Frame -Wood
Mbalh
13
5
0 9
0
45.0 ft'
0
0.25
0.5
0
_ 5',
N
Exterior Frame -Wood
Laundry
13
13
0 9
0
117.0 ft'
0
0.25
0.5
0
6
E
Exterior Frame - Wood
Laundry
13
7
0 9
0
63.0 ft2
0
0.25
0.5
0
_ 71
N
Exterior Frame- Wood
Kitchen
13
11
o 9'-'
0
99.0 ft'
0
0.25
0.5
0
8�,
S
Exterior Frame, -Wood
Living Room
13
17
6 9
0
157.5 ft'
0
0.25
0.5
0
91
E
Exterior Frame -Wood
Family Rm
13
3
0 9
0
27.0 ft'
0.25
0.5
0
-10,
S .
Exterior Frame -Wood
Family Rm
13
14
6 9
0
130.5 ft2
0.25
0.5
0
_ 11
W
Exterior -Frame - Wood
Family Rm
13
3
0 9
0
27.0 ft'
0
0.25
0.5
0
_ 12
S
Exterior Frame - Wood
Bed 2
13
11
6 9
0
103.5 ft2
0.25
0.5
0
13
W
Exterior Frame -Wood
Bed
13
11
0 9
0
99.0 ft2
0
0.25
0.5
0
_ 14
S
Exterior Frame - Wood
c2
13
2
6 9
0
22.5 ft'
0
0.25
0.5
0
_ 16
N
Exterior Frame - Wood
Bed 3
13
11
6 9
0
103.5 ft2
0
0.25
0.5
0
_ 16
W
Exterior Frame -Wood
Bed 3
13
12
0 9
0
108.0 ft2
0.25
0.5
0
_ 17
N
Exterior Frame -Wood
c3
13
3
6 9
0
31.5 ft'
0
0.25
0.5
0
_ 18
N
Exterior Frame -Wood
Bath
13
5
0 9
0
45.0 ft2
0
0.25
0.5
0
_ 19
N
Exterior Frame -Wood
Bed 4
13
11
0 9
0
99.0 ft'
0
0.25
0.5
0
20
N
Exterior Frame- Wood
c4
13
4
0 9
0
36.0 ft2
0
0.25
0.5
0
1/9/2019 12:51 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6
I-UKIvI K4U0-LU I r
DOORS
# Ornl Door Type Space Stones U-Value Ft Width In Fi eightln Area
1 N Wood Laundry None .3 3 7 21 ft2
2 S Wood Living Room None .3 3 7 21 ft
Wall
#
Ornl
ID
Frame
Panes
1
S
2
None
Single (Clear)
2
E
4
None
Single (Clear)
3
N
5
None
Single (Clear)
_ 4
N
7
None
Single (Clear)
5
S
8
None
Single (Clear)
6
S
8
None
Single (Clear)
7
S
10
None'
Single (Clear)
_ 8
S
12
None
Single (Clear)
_ 9
N
15
None
Single (Clear)
_ 10
N
18
None
Single (Clear)
11
N
19
None
Single (Clear)
# :Scope Method
1 Wljolehouse Proposed ACH(50)
WINDOWS
NFRC
U-Factor SHGC
Imp
Yes
0.7 0.5
Y
18
Yes
0.7 0.5'
Y
9.
Yes
0.7 0.5
Y
9.
Yes
0.7 0.5
Y
9.
Yes
0.7 0.5
Y
7.
Yes
0.7 0.5
Y
36
Yes
0.7 0.5
Y
36
Yes
0.7 0.5
Y
18
Yes
0.7 0.5
Y
18
Yes
0.7 0.5
Y
9.
Yes
0.7 0.5
Y
3
6
Overhang
Area Depth Separation Int Shade Screening
.0 $2 0 ft 0 in 0 ft 0 in Drapes/blinds Exterior 5
0 ft' 0 ft.0 in 0 ft 0 in Drapes/blinds Exterior 5
0 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds Exterior 5
0 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds Exterior 5
0 ft2 0 1110 in 0 ft 0 in Drapes/blinds Exterior 5
.0 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds Exterior 5
.0 ft' 0 ft 0 in 0 ft 0 in Drapes/blinds Exterior 5
.0 ft2 0 It 0 in 0 ft 0 in Drapes/blinds Exterior 5
.0 ft2 0 It 0 in 0 ft 0 in Drapes/blinds Exterior 5
0 ft' 0 ft 0 in 0 ft 0 in Drapes/blinds Exterior-5
.0 ft' 0 ft 0 in 0 ft 0 in Drapes/blinds Exterior 5
ACH ACH 50
.2086 5
# System Type Subtype Efficiency Capacity Block Ducts
_1 Electric Strip Heat/ None COPA 27.3 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER: 14 36 kBtu/hr cfm 0.7 1 sys#1
HOT WATER SYSTEM
# System Type SubTpe Location EF Cap Use SelPnt Conservation
1 Electric None Laundry 0.97 40 gal 60.9 gal 120 deg None
1/9/201912:51 PM
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 5 of 6
ACH ACH 50
.2086 5
# System Type Subtype Efficiency Capacity Block Ducts
_1 Electric Strip Heat/ None COPA 27.3 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER: 14 36 kBtu/hr cfm 0.7 1 sys#1
HOT WATER SYSTEM
# System Type SubTpe Location EF Cap Use SelPnt Conservation
1 Electric None Laundry 0.97 40 gal 60.9 gal 120 deg None
1/9/201912:51 PM
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 5 of 6
# System Type SubTpe Location EF Cap Use SelPnt Conservation
1 Electric None Laundry 0.97 40 gal 60.9 gal 120 deg None
1/9/201912:51 PM
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 5 of 6
1/9/201912:51 PM
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 5 of 6
rr M%A oene nn47
rVl\IVI I\t VJ-GV 11
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart #
Company Name
System Model # Collector Model
# Area
Volume
FEF
None
None
ft'
DUCTS
— Supply
—
—Return'—
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic 6
290 fF
Attic
73 ft Default Leakage
AC
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Cooling Jan
Heating [X] Jan
((]] Feb
[X1 Feb
[[ ]] Mar
[X] Mar
Apr E
.May [[X]] Jun [X] Jul
Jun [)Jul
[X] Aug
[ ]Aug
[X] Sep
[ 1 Sep
[ j
1.1
Oct [rX
Oct
Nov
Nov
[�X]] Dec
Venting [)Jan
[ ]) Feb
[[fix]) Mar
Apr [
May l l Jun [ 1 Jul
[) Aug
[) Sep
lXl
[X�
[ ]Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78 78 78
78
78
78
78
78
80
78
80
78
80
78
80
78
PM
80
80
80
80 78
Cooling (WEH)
AM
78
78
78
78 78 78
78
78
78
78
78
80
78
8o
78
80
78
80
78
PM
80
80
80
80 78
Heating (WO)
AM
65
65
65
65 65 65
65
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65 65 65
65
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
68
68
1/9/2019 12:51 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 6
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
4000 Avenue L, Ft. Pierce, FL, 34947
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft0
7. Windows" Description
a. U-Factor: Sgl, U=0.70
SHGC: SHGC=0.50
b. U-Factor. N/A
SHGC:
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. WA
New (From Plans)
Single-family
1
4
No
1450
Area
205.00 ft'
ft'
ft'
ft'
0.000 ft
0.500
Insulation Area
R=0.0 1448.00 ft'
R= ft'
R= ft'
9. Wall Types
a. Frame - Wood, Exterior
b. N/A
c. N/A
d. N/A
10. Ceiling Types
a. Under Attic (Vented)
b. N/A
c. WA
11. Ducts
a. Sup: Attic, Ret: Attic, AH: AC
12. Cooling systems
a. Central Unit
13. Healing systems
a. Electric Strip Heat
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant feats --�
Builder Signature: y� -� Date: WrA \
Address of New Home:
City/FL Zip:
Insulation
R=13.0
R=
R=
R=
Insulation
R=38.0
R=
R=
Area
1593.00 ft'
ft'
ft'
ft'
Area
1450.00 ft'
ft'
ft'
R ft'
6 290
kBtulhr Efficiency
36.0 SEER:14.00
kBtu/hr Efficiency
27.3 COP:1.00
Cap: 40 gallons
EF: 0.97
CF. WHF
'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/9/2019 12:52 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1