HomeMy WebLinkAboutEVALUATION REPORTCREEK Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813) 48D-3421
EVALUATION REPORT FLORIDA BUILDING CODE, a EDITION (2017)
Manufacturer: TAMKO BUILDING PRODUCTS
220 West a Street
Joplin, MO 64801
(417)624-6644
Manufacturing Plants: Joplin, MO
Phillipsburg, KS
Frederick, MD
Dallas, TX
Tuscaloosa, AL
Quality Assurance: UL LLC (QUA9625)
SCOPE
Issued September25, 2017
SCANNED
BY
St• Lucie County
Category: Roofing
Subcategory: Asphalt Shingles
Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.6.5.1
Properties: Physical properties, Wind Resistance, Wind Driven Rain
REFERENCES
Ent!
Report No.
Standard
Year
PRI Construction Materials Technologies (TST5878)
TAP-043-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-051-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-054-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-114-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-117-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-130-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-131-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-165-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-28D-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-303-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP307-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP314-02-01 Rev 2
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-315-02-01
ASTM D 6381
2008(2013)e1
PRI Construction Materials Technologies (TST5878)
TAP-317-02-01
TAS 100
1995
UL LLC (TST9628)
02NK9507
ASTM D 3161
2016
UL LLC (TST9628)
04NK24366
ASTM D 3462
2010A
UL LLC (TST9628)
05NK28006
ASTM D 6381
2008(2013)e1
UL 2390
ASTM D 7158
2011
UL LLC (TST9628)
06NK03898
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
08CA59132
ASTM D 3161
2016
UL LLC (TST9628)
09NK07896
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
IOCA50498
ASTM D 3462
201 DA
UL LLC (TST9628)
10CA64882
ASTM D 3161
2016
UL LLC (TST9628)
11NK14014
ASTM D 3161
2016
ASTM D 3462
201 DA
UL LLC (TST9628)
12CA24551
ASTM D 3161
2016
UL LLC (TST9628)
4786110543
ASTM D 6381
2008(2013)e1
UL LLC (TST9628)
4787043752
ASTM D 3161
2016
UL LLC (TST9628)
4787148748
ASTM D 7158
2011
ASTM D 3161
2016
ASTM D 3462
201 OA
CREEK Technical Services LLC (ANE11669)
TBP15001.3
Calculations
2017
TBP15001.4
FL1B355.R4
Paae 1 of 11
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Elite GlassSeal®
12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
(Frederick, Joplin &
asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa)
ceramic granules complying with ASTM D 3462.
Glass -Seal
12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
(Frederick &
asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa)
ceramic granules complying with ASTM D 3462.
Glass -Seal
12-1/4" x 36", ASTM D 7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass
(Joplin)
mat coated on both sides with asphalt and surfaced with ceramic granules complying
with ASTM D 3462. Shingles shall be used in the non-HVHZ only.
Heritage®
13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas, Frederick,
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Joplin, Phillipsburg &
complying with ASTM D 3462.
Tuscaloosa)
Heritage® Premium
13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas, Frederick,
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Phillipsburg &
complying with ASTM D 3462.
Tuscaloosa)
Heritage® Premium
12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Frederick)
laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage® Vintage®
17-1/2" x 40", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Phillipsburg)
laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage® Woodgate
13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas & Frederick)
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
complying with ASTM D 3462.
Heritage® Woodgate
12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural
(Frederick)
asphalt shingle surfaced with mineral granules complying with ASTM D, 3462. Shingles
shall be used in the non-HVHZ only.
Hip and Ridge Shingles
12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt
(Frederick & Joplin)
shingle surfaced with mineral granules complying with ASTM D 3462.
Vintage® Hip and Ridge
12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle
(Phillipsburg)
surfaced with mineral granules complying with ASTM D 3462.
TBP15001.4 FL18355-R4 Page 2 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor Imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
INSTALLATION
Elite GlassSeal®
Basic Wind Speed (Vat):
(Frederick, Joplin &
Basic Wind Speed (V w)
Tuscaloosa)
Deck (HVHZ):
&
Glass -Seal
(Frederick, Joplin (Non-
HVHZ) & Tuscaloosa)
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation (HVHZ):
Installation (Nan-HVHZ)
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturers application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5-1/8 inch exposure in accordance with RAS
115 and manufacturers published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5-1/8-inch exposure in accordance with FBC
requirements and manufacturers published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or "6 Nail Pattern" detailed below.
70
5-1/8"
Butt Edge
Figure 1. Elite Glass -Seal & Glass -Seat
4 Nail Pattern (Non-HVHZ only)
NAILS
7180
i-1/8"
Butt Edge
Figure 2. Elite Glass -Seal & Glass -Seal
6 Nail Pattern
TBP15001.4 FL18355-R4 Peas 3 of 1
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor Imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Heritage®
Basic Wind Speed (V,rr):
(Dallas, Frederick, Joplin,
Basic Wind Speed (Vaw)
Phillipsburg & Tuscaloosa)
Deck (HVHZ):
Heritage® Premium
(Dallas, Frederick
Phillipsburg & Tuscaloosa)
Deck (Non-HVHZ):
&
Heritage® Woodgate
(Dallas & Frederick)
Undedayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ)
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturers application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5-5/8 in. exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5-5/8 in. exposure in accordance with FBC
requirements and manufacturers published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or "6 Nail Pattern" detailed below.
FASTENERS NAIL ZON E
�COMMON
BOND
6-1/8"1 1 1 l 11 I I EXPOSURE S-6/8"
1 " h-- 12-1 /211 —�*— 12-31811 —+— 12-1 /21`h-111
Figure 3. Heritage®, Heritage® Premium, and Heritage® Woodgate (Dallas)
4 Nail Pattern (non-HVHZ only)
FASTENERS NAIL ZONE
COMMON
�a. BOND
EXPOSURE 5-518"
1"� �-7-1/2'�-7-1/2"i�t 7�8"�7-1I2"-►�T-i/2"�
Figure 4. Heritage® & Heritage® Premium
6 Nail Pattern
TBP15001.4
4 of 11
I his evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes thmughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
1� �7-1/2"�-7-1/2'�-7-3/8=►�7-1/2�t7-1/2� �-1"
Figure 5. Heritage® Woodgate
6 Nail Pattern
PAINT
7-7/8rr
TAMKO BUILDING PRODUCTS
Asphalt Shingles
W
BOND
Common Bond
Figure 6. Heritage®, Heritage® Premium, & Heritage® Woodgate
Alternate 6 Nail Pattern
ACCEPTABLE
FASTENER LOCATION
DO NOT FASTEN
ALONGEDGE OF
COMMON BOND
ZONE
Figure 7. Heritage® (Tuscaloosa)
Expanded Nail Zone
Nall patterns from Figures 3, 4, and 6 may be placed in the nall zone as described above
TBP15001.4 FL16355-114 Page 5 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC,of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Heritage® Premium Basic Wind Speed (Vwr):
(Frederick) Basic Wind Speed (V,,d):
Deck (HVHZ):
Deck (Non-HVHZ):
Undedayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ):
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min. 7116 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturers application instructions when installing
shingles at slopes greater than 21:12. .
Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or "6 Nail Pattern" detailed below.
Figure 8. Heritage® Premium (Frederick)
4 Nail Pattern (non-HVHZ only)
FASTENERS
5"
1 n� �91hn gn�n 9th--rl I~� n
Figure 9. Heritage® Premium (Frederick)
6 Nail Pattern
TBP15001.4 FL18355-R4
ZONE(
MON BOND
ZONE/
MON BOND
6 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Heritage® Woodgate Basic Wind Speed (Vol):
(Frederick) Basic Wind Speed (V°m):
Deck (Non-HVHZ):
Undedayment:
Min. slope:
Installation (Nan-HVHZ):
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max.150 mph
In accordance with FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min. 7116 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattem" or "6 Nail Pattern"detailed below.
--r�I T
EXPOSURE V
■1
1'LA [,ii— 11" 4-12-318n--111,1111— 11"
Figure 10. Heritage@ Woodgate (Frederick)
4 Nail Pattern (non-HVHZ only)
S.
1"-� �9.1/2"�►�3' 9$/8° 3 9-112°-� �4°
Figure 11. Heritage@ Woodgate (Frederick)
6 Nail Pattern
Cl
BOND
FJ
BOND
7 of 11
1 his evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
dCREEK
TECHNICAL SERVICES, LLC
Heritage® Vintage® Basic Wind Speed (V,e):
(Phillipsburg) Basic Wind Speed (V.m):
Deck (HVHZ):
5001.4
Deck (Non-HVHZ):
Undedayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ):
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19132 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturers published installation
instructions. Shingles shall be attached using either "5 Nail
Pattern" or "6 Nail Pattern" detailed below.
�to-va•� i�—w3n•�
Figure 12. Heritage® Vintage®
5 Nail Pattern (non-HVHZ only)
Figure 13. Heritage® Vintage®
6 Nail Pattern
FL18355•R4
k�.
wan
8 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Hip & Ridge Basic Wind Speed (Vmr):
(Frederick & Joplin) Basic Wind Speed (Ve,d):
Deck (HVHZ):
Deck (Non-HVHZ):
Undedayment:
Min. slope:
Installation:
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15132 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min. 7116 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements.
Installed with 5-1/8 inch exposure in accordance with the
FBC and manufacturer's published installation instructions.
The direction of the exposed end shall be away from the
prevailing wind.
Direction of prevailing wind
exposure
Figure 1
ner
n
Figure 2
Figure 14. Hip & Ridge (Frederick & Joplin)
)xposure
TBP15001A FL18355-114 Page 9 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G203. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
ACREEK
TECHNICAL SERVICES, LLC
Vintage® Hip & Ridge Basic Wind Speed (Vut):
(Phillipsburg) Basic Wind Speed (V.w):
Deck (HVHZ):
Deck (Non-HVHZ):
Undedayment:
Min. slope:
Installation:
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements.
Installed with 5 inch exposure in accordance with the FBC
and manufacturers published installation instructions. The
direction of the exposed end shall be away from the
prevailing wind.
Direction prevailing wind
exposure
Figure 1
1"
r ,, ,'I Fastener
�'' 5-1/2,
Figure 2
(posure
,rlgure 3
Figure 15. Vintage® Hip & Ridge (Phillipsburg)
TBP15001.4 FL16355-R4 Page 10 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor Imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
3) The mean roof height shall be restricted to a maximum 33 It in the HVHZ.
4) Classification to ASTM D 7158 applies to exposure B & C with a building mean roof height of 60-ft or less.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underiayment application.
6) Shingles shall be installed starting at the save in horizontal layers such that the laps shed water from the
deck.
7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and code compliant detail shall prevail.
8) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 6" Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
No 74021
O'.. STATE OF :�1j/
CERTIFICATION OF INDEPENDENCE
2017.09.25
11:31:41
04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE11669
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
TBP15001.4
END OF REPORT
FL18355-R4
11 Of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.