HomeMy WebLinkAboutEVALUATION REPORTRECEIVED
DECa 2018 MEMO l etc.
Certificate of Authorization #32455
ST. Lucie county, Permitting 353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
.ENGINEER—� EVALUATE TEST CONSULT CERTIFY
EVALUATION REPORT
Polyglass USA, Inc.
1111 West Newport Center
Deerfield Beach, FL 33442;
(954)233-2230
Evaluation Report P12060.02.09-R24
FL5259-R28
SCANNED Date of Issuance: 02/24/2009
BY Revision 24: 01/24/2028
St. Lucie County
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass Roof. Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. Of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMOJetc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOietc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by:
_r
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DC4ANE1983
The facsimile seal appearing was authorized by Robert Nleminen,
P.E. on 01124/2018. This does not serve as an electronically
signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMOletc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMOIetc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither NEMOIetc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
�YT � .iy � f � 4 • i.
s fi �
ONEMOletc.
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the a Edition (2017) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Pro a
Standard
Year
1504.3.1
Wind Uplift
FM 4474
2011
1504.3.1
Wind Uplift
UL 1897
2012
1507.2.3 / 1507.1.1
Physical Properties
ASTM D226
2009
1507.2.4 / 1507.1.1,1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2012
2012
1507.11.2
Physical Properties
ASTM D6164
2011
1507.11.2
Physical Properties
ASTM D6222
2011
TAS 110
Accelerated Weathering
ASTM D4798
2011
3. REFERENCES:
Emint
Examination
Reference
Date
FM Approvals (TST 1867)
Wind Uplift
3004091
01/12/2000
PRI (TST 5878)
Physical Properties
PRIO1111
04/08/2002
PRI (TST 5878)
Physical Properties
PUSA-005-02-01
01/31/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-01
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-02
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-03
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-018-02-01
07/14/2003
PRI (TST 5878)
Physical Properties
PUSA-02MZ-01
07/13/2005
PRI (TST 5878)
Physical Properties
PUSA-033-02-01
01/12/2006
PRI (TST 5878)
Physical Properties
PUSA-035-02-01
09/29/2006
PRI (TST 5878)
Physical Properties
PUSA-055-02-02
12/10/2007
PRI(TSTS878)
Physical Properties
PUSA-061-02-02
01/28/2008
PRI (TST 5878)
Physical Properties
PUSA-076-02-01
02/22/2008
PRI (TST 5878)
Physical Properties
PUSA-083-02-01
04/14/2008
PRI (TST 5878)
Physical Properties
PUSA-088-02-01
07/29/2009
MTI (TST 2508)
Physical Properties
JX20H7A
04/01/2008
MT] (TST 2508)
Physical Properties
RX14E8A
01/29/2009
ERD (TST 6049)
Physical Properties
11752.09.99-1
02/08/2000
ERD (TST 6049)
Wind Uplift
11757.08.01-1
08/13/2001
ERD (TST 6049)
Wind Uplift
11776.06.02
01/16/2003
ERD (TST 6049)
Physical Properties
02200.07.03
07/14/2003
ERD (TST 6049)
Wind Uplift
P1740.01.07
01/04/2007
ERD (TST 6049)
Physical Properties
P5110.04.07-1
04/11/2007
ERD (TST 6049)
Wind Uplift
P9260.03.08
03/21/2008
ERD (TST 6049)
Physical Properties
P13450.08.09
08/13/2009
ERD (TST 6049)
Wind Uplift
P30540.11.09-RS
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09.1
11/30/2009
ERD (TST 6049)
Wind Uplift
P11030.11.09-2
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-3
11/30/2009
ERD (TST 6049)
Physical Properties
P33360.06.10
06/25/2010
ERD (TST 6049)
Physical Properties
P33370.03.11
03/02/2011
ERD (TST 6049)
Physical Properties
P33370.04.11
04/26/2011
ERD (TST 6049)
Physical Properties
P37300.10.11
10/19/2011
NEMO ETC, U.C.
Evaluation Report P32060.02.09-RZ4
Certyf o o7Authortra lon#32455
a EDITION (2017) FBC NON-HVHZ EVALUATION
FL5259-R28
Polyglass Roof Underlayments; (954) 2.33-1230
Revision 24:01/24/2018
Page 2 of 14
ONEMOjetc.
Entivit Examination Reference Date
ERD (TST 6049) Physical Properties P40390.08.12-1 O8/06/2012
ERD (TST 6049) Physical Properties P40390.08.12-2 08/07/2012
ERD (TST 6049) Physical Properties C41420.09.12-3 09/11/2012
ERD (TSr 6049) Wind Uplift P39680.03.13 03/04/2013
ERD (TST 6049) Physical Properties P45370.04.13 04/26/2013
ERD (TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013
ERD (TST 6049) Wind Uplift 11757.04.01-1-Ri 04/30/2013
ERD (TST 6049) Wind Uplift P41630.08.13 08/06/2013
ERD (TST 6049) Wind Uplift P31751.05.03-R1 11/26/2013
ERD (TST 6049) Wind Uplift P31781.11.03-R1 11/26/2013
ERD (TST 6049) Physical Properties P45270.05.14 05/12/2014
ERD (TST 6049) Physical Properties 6020.07.14-1 09/08/2014
ERD (TST 6049) Physical Properties 6020.09.14-2 09/08/2014
ERD (TST 6049) Physical Properties 6020.09.14-3 09/08/2014
ERD (TST 6049) Physical Properties 6020.09.14-4 09/08/2014
ERD (TST 6049) Physical Properties 6020.09.14-5 09/08/2014
ERD (TST 6049) Physical Properties 6020.09.146 09/08/2014
ERD (TST 6049) Physical Properties P46520.10.14 10/03/2014
ERD (TST 6049) Physical Properties P43290.10.14 10/17/2014
ERD (TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015
ERD (TST 6049) Physical Properties P40390.04.15 04/03/2015
ERD (TST 6049) Physical Properties P44360.10.14-R1 05/18/2015
ERD (TST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015
ERD (TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016
ERD (TST 6049) Physical Properties PLYG-SC8080.07.16 07/16/2016
ERD (TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016
ERD (TST 6049) Physical Properties PLYG-SC33040.12.16 12/27/2016
ERD (TST 6049) Physical Properties PLYG-SC31900.03.17 03/10/2017
ERD (TST 6049) Physical Properties PLYG-SC32315.08.17 08/08/2017
ICC-ES(EVL 2396) IBC Compliance ESR-1697 11/01/2014
Miami -Dade (CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015
Polyglass USA Manufacturing Affidavit Products Current 02/18/2009
Polyglass USA P/LAffidavit Mule -Hide Cross Ug 03/01/2008
Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011
UL, LLC. (QUA9625) Quality Control Service Confirmation Exp.10/05/2018
4. PRODUCT DESCRIPDON:
MechanicallyFasteneclUnderlayments f ,
4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet.
4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet.
4.2.1 Polystick MTS or Polystick MTS PLUS is a nominal 60-mil thick rubberized alpha
fiber reinforced, surfaced with polyolefinic film surface; meets FRSA/TRI Apri12012.
4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface; meets ASTM D1970.
4.2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a
polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012.
NEMO ETC, U.C. Evaluation Report P12060.02.09-R24
Certifimte of Authorization#32455 6TM EDITION (2017)FBC NON-HVHZ EVALUATION FL5259-R28
Polyglass Roof Underiayments; (954) 233-223D Revision 24: 01/24/2018
Page 3 of 14
ONEMOletc.
4.2.4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced, with a granular surface; meets FRSA/TRI April 2012.
4.2.5 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/mz polyester
fabric surface; meets ASTM D1970 and FRSA/TRI April 2012.
4.2.6 Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester
reinforced, APP modified bitumen cap sheets; meet FRSA/TRI April 2012.
4.2.7 Polystick Dual PrdTM is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970.
4.2.8 Polystick Tile ProW" is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012.
4.2.9 Polystick MU-X is a nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section
5.8).
4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SBS
modified bitumen back -side and granule -surfaced APP modified bitumen top -side. Elastoflex G TU is for use as an
alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April
2012 (0442) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap. Sheet" in the "Two Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems.
4.3.2 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164.
Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380,
Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems.
Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "fwo Ply System" from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an
alternate to Hot Asphalt applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath
mechanically fastened tile roof systems.
4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
Polyflex G is for use as an alternate to Heat Applied "Cap Sheet" in the'Two Ply System" from FRSA/TRI April 2012
(04-12) beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat
Applied "Cap Sheet" in the `Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO)etc. nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Underlaymehts may be used with any prepared roof coverwhere the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
NEMO ETC, LLC. Evaluation Report P32060.02.09-1124
CeNRrore of Autharkarion#32455 a EDITION(2017) FBC NON-HVHZ EVALUATION FL5259-R28
Polyglass Roof Underlayments; (954) 233.1230 Revision 24:01/24/2018
Page 4 of 14
NNEMOjetc.
5.5 Allowable Roof Covers:
„e, s `'.,ym .+ �„3 ;ROOF
COVEROPTIONS"„"';? �; ,, .,.
.✓a-: sx" 3, _ �-.
r ..
Underiayment
Asphalt Shingles
Nall -On Tile
Foam -On Tile
Metal
Wood Shakes
& Shingles
Slate
Elastobase
Yes
Yes
(gaze Sheet 4n2-plysptem)
Yes
(Base Sheet In 2-ply system)
Yes
Yes
Yes
Elastobase P
Yes
Yes
(Base Sheetln2-plysyAem)
Yes
(Base Sheet in 2-ply system)
Yes
Yes
Yes
Polyglass G2 Base
No
Yes
(Base Sheet in 2-pN system)
Yes
(Base Sheet In 2-ply system)
No
No
No
Polyglass APP Base
No
Yes
(Base Sheet in 2-ply system)
Yes
(Base Sheet ln2-p1ynm.M)
No
No
No
Polystick NITS or NITS PLUS
Yes
Yes
No
Yes
Yes
Yes
Polystick IR-Xe
Yes
No
No
No
Yes
Yes
Polystick TUP
No
Yes
Yes (See 5.5.1)
No
No
No
Polystick TU Plus
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
PolystickTU Max
No
Yes
Yes (See 5.5.3)
Yes
No
No
Polystick Dual Pro
Yes
No
No
Yes
Yes
Yes
Polystick rile Pro
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
Polwdck MU-X
Yes
No
No
Yes
Yes
Yes
Elastoflex S6G
Yes
Yes
Yes (See 5.5.3)
No
Yes
Yes
Elastafex S6 G FR
Yes
Yes
No
No
Yes
Yes
Elastoflex G TU
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
PolyflexG
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
PolyflexG FR
Yes
Yes
No
No
Yes
Yes
Polyflex SAP or SAP FR
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Mule -Hide SA-APP Cap Sheet
or SA-APP Cap Sheet (FR)
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
.,- .. ...
' r TABLE
.-.. :... m -.. ---
3At ALLOWABLE,'fILE ADHESIVE f.UN0ERIAYMENT COMBINATIONS
Adhesive
FloridaProduct
Underlayments
Approval
DAP Foam Touch'n Seal Stormllond Roof
FL14506
Polystick TU Plus, Polystick TU Max
Tile Adhesive
Dow TileBond"'
FL22525
Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Polyset® AH-160
FL6332
Elastoflex G TU, Elastoflex56 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Polyset® RTA-1
FL6276
Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
2 Refer to Tile Manufacturer's or Adhesive Manufacturers Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, U.C. Evaluation Report P32060.02.09-R24
rertlptate of Avthorizatlan#32455 6ax EDITION (2017) FBC NON-HVHZ EVALUATION FI5259-R28
Polyglass Roof Underlayments; (954) 233-1230 Revision 24:01/24/2018
Page 5 of 14
ONEMOletc.
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR) self -adhered to:
D New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing
plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels
(designed and installed to meet wind loads for project).
Note: Polyglass does not require priming of new or existing plywood or 05B sheathing. New or existing plywood or
OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ ASTM D41 primed structural concrete.
Polyflex G or Polyflex G FR torch -applied to:
D ASTM D41 primed structural concrete.
5.6.2 Bond -to -Insulation:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered
to:
➢ ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
D Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
Polyflex G or Polyflex G FR torch -applied to:
➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
5.6.3 Bond to Mechanically Attached Base Laver:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or
Tile Pro self -adhered to:
➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
D ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex G FR torch -applied to:
➢ Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For Installations under foam -on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in
accordance with FBC Section 1504.3.1.
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R24
ceMilcoreofAuthor&otlon#32455 e EDITION (2017) F8C NON-HVHZ EVAWATION FL5259-RZS
Polyglass Roof Underlayments; (954) 233-1230 Revision 24: OV24/2018
Page 6 of 14
ONEMOletc.
5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2D12 (04-
12), Appendix A, Table IA or FBC 1609 for determination of design wind loads.
#1 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None `
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#2 Maximum Design Pressure = -97.5 psf
Deck: Min..15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PGIOD or ASTM D41
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
1Y." ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
#3 Maximum Design Pressure = -105 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
SY." ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. `
#4 Maximum Design Pressure =-135 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PGI00 or ASTM D41
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#5 Maximum Design Pressure = -315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap
Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#6 Maximum Design Pressure=-622.5_psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#7 Maximum Design Pressure =-30.0 psf':
Deck: Min. 15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-Inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
NEMO ErC, LLC. Evaluation Report P32060.02.09-R24
cerripcom of Authork0lon#32455 6r"EDITION (2017)FBC NON-HVHZ EVALUATION FL5259-R28
Polyglass Roof Underlayments; (954) 233.1230 Revision 24:01/24/2018
Page 7 of 14
ONEMOletc.
#8 Maximum Design Pressure = -37.5 Rsf':
Deck: Min. 15/32-Inchplywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poiy-film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-Inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-Inch wide side laps and 6-Inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#9 Maximum Design Pressure =-37.5 osf':
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) or two (2) layers ASTM D226, Type 11 felt
Fasteners: - 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-Inch wide side laps and 12-Inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt.
#10 Maximum Design Pressure = -45 osf':
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) layer ASTM D226, Type 11 felt
Fasteners: 11 ga. x 1.25-inch x 3/8-inch,head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 2-inch wide side laps and 4-Inch o.c, at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU, applied in full mopping of hot asphalt.
#11 Maximum Design Pressure = -45 osf•:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Autf'tarity Having Jurisdiction.
Base Sheet: Two (2) layers ASTM D226, Type It felt
Fasteners: 11 ga.x 1.25-Inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c. at the 2-inch wide side laps and 9-Inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot
asphalt.
#12 Maximum Design Pressure = -45 Dsf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners -
Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#13 Maximum Design Pressure = -52.5 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied tap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#14 Maximum Design Pressure =-52.5 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c, at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
NEMO ETC, I.I.C. Evaluation Report P32060.02.Q9-RZ4
Cennmte of Authorirm/an#32455 6r"EDITION (2017)FBC NON-HVHZ EVALUATION FL5259-R28
Polyglass Roof Underlayments; (954) 233-1230 Revision 24: OV24/2018
Page 8 of 14
ONEMOletc.
#15 Maximum Design Pressure=-52-S psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TO or Elastoflex 56 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied.
#16 Maximum Design Pressure = -60 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: 11 ga. x 1.25-inch long x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin caps
Spacing: B-inch ol. at the 4-inch wide side laps and 8-Inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TO or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#17 Maximum Design Pressure =-60 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c. at the 4-Inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TO or Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied.
#18 Maximum Design Pressure = -67.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: 12 ga. x 1.25-Inch long x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/84nch diameter tin caps
Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-Inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TO or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#19 Maximum Design Pressure = -75 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 10-inch o.c. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TO or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#20 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-Inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TO or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#21 Maximum Design Pressure=-90 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal -
Plates
Spacing: 6-Inch o.c. at the 4-Inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TO or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#22 Maximum Design Pressure =-90 psi:
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-Inch o.c. at the 4-Inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TO or Elastoflex S6 G, applied in full mopping of hot asphalt.
NEMO ETC, U.C. Evaluation Report P32060.02.09-R24
Certificate ofAuthorimtion 432455 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28
Polyglass Roof Underlayments; (954) 233.1230 Revision 24: 01/24/2018
Page 9 of 14
ONEMOletc.
#23 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with QMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 9-Inch o.c. at the 4-inch wide side laps and 9-Inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied In full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#24 Maximum Design Pressure = -97.5 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nall Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 4-Inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#25 Maximum Design Pressure =-105 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-Inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#26 Maximum Design Pressure = -112.5 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nall Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin caps
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer at all tin -caps
Base Ply: Polystick MTS or Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#27 Maximum Design Pressure =-120 psf:
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c. at the flinch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#28 Maximum Design Pressure=-120psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-Inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt.
5.6.4.1 All other direct -deck, adhered Potyglass underlayment systems beneath foam -on tile systems carry a Maximum
Design Pressure of -45 psf.
NEMO ETC, U.C. Evaluation Report P32060.02.09-R24
Ceniilcate ofAuthodration N32455 6TM EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28
Polyglass Roof Underlayments; (954) 233-2230 Revision 24: 01/24/2018
Page 10 of 14
ONEMOletc.
5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed
that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WDl, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked
with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January
2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation.
Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for
longer than 180-days after installation.
Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30
days.
Elastoflex S6 G or Elastoflex S6, G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the
prepared roof covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum
exposure is 180 days.
5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as
set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance.
5.9 Tile Slippage Limitations (FRSA/TRI April 2012 (04-121):
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as
TL___ i....,, n...;.n«;..,.c ,-nn nnly he exceeded by using battens during loading of the roof tiles.
w ioiwa, i uoc S OPC
�c 1' .• '.-TABLE
Underlayment
Elastoflex G TU
..........,..... __.. ...., __ - - -
2: TILESUPPAGE LIMTATIONS FDA 'DIRECT-DECKTILE INSTALLATIONS
Tile Profile Staging Method Maximum Slope
Flat 30-tile stack 7:12
Lugged
8-tile stack (6 over 2)
6:12
Elastoflex 56 G or S6 G FR
Polystick MTS or MTS PLUS
Flat or Lugged
Flat
6-tile stack (4 over 2)
6-tile stack (4 over 2)
4:12
5:12
Lugged
6-tile stack (4 over 2)
4:12
Polystick Tile Pro
Polystick TU Max
Flat or Lugged
Flat
6-tile stack (4 over 2)
6-tile stack (4 over 21 or 10-tile stack
7:12
7:12
Lugged
6-tile stack (4 over 2)
7:12
Lugged
10-tile stack
6:12
Polystick TUP
Flat
- 6-tile stack (4 over 2)
6:12
Lugged
6-tile stack (4 over 2)
4:12
Polystick TU Plus
Flat or Lugged
6-tile stack (4 over-
7:12
Flat or Lugged
10-tile stack
6:12
Polyflex G or G FR
Polyflex SA P or SA P FR
Flat or Lugged
Flat or Lugged
6-tile stack (4 over 2)
6-tile stack (4 over 21
4:12
4:12
Evaluation Report P12060.02.09-R24
NEMO ETC, U.C. FL5259-1128
o,d1fl,.W o)Authadz&inn H32455 e EDITION (2017) FEIC NON-HVHZ EVALUATION
Polyglass Roof Underlayments; (954) 233-1230 Revision 24:01/24/2018
Page 11 of 14
ONEMOletc.
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
6.3.1 Non -Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA
P Fit, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex 56 G or
Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex. G Fit, torch applied. Roof cover limitations are those are
those associated with the top -layer underlayment, as set forth in Table 1.
6.3.2 Tile Applications:
Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the'Two
Ply System" from FRSA/TRI April Z012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with
FRSA/TRI April Z012 (04-12) Installation Manual.
6 4�+a?'xPotystick'�MTS, MTS'PLUS; IR Xe TU P,rTU Plus, TU Mex, Qual Pro, Tile P,ro or MUX r Polyflex SAP, Polyflex SAPbFR,
Mule H, de SA APPCa Sheet 4r NlulenHide S APP .Sheet (FR
F; 4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 (except Polystick TU P) underlayment
6.4.2
in FBC Table 1507.1.1 for the type of prepared roof covering to be installed.
Direct -to -Deck with Mechanically Fastened Roof Covers:
All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP
Cap Sheet or SA- APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -
Hide back nailing guidelines. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch
diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -
nailed using the above noted fasteners and spacing, in area marked "nail area, area para claval" on the face of
membrane. The head lap membrane is to cover the area being back -nailed.
All seal -lap seams (selvage laps) must be K
firmly rolled with a minimum 28 lb. hand
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric).
wew of Ovelap Seam of Dual Pro and Tile Pro
All over -fabric and over -granule end -laps shall have a 6-Inch wide, uniform layer of Polyplus 50 Premium Modified
Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap.
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys,
or exposed roof to wall details
MEMO ETC, U.C. Evaluation Report P32060.02.09-R24
Certificate of Authorization N32455 63N EDITION (2017) FBC NON-HVHZ EVALUATION FLSZ59-RZS
Polyglass Roof Underlayments, (954) 233.1230 Revision 24:01/24/2018
Page 12 of 14
ONEMOjetc.
Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, If needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be Installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb.roller) or small areas of the
roof that are not accessible to a large roller or broom.
6.4.3 Tile Applications (not allowed for Polystick Dual ProIR-Xe or Polystick MU-X):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.4 herein.
6.4.4 Two (2) Ply Underlayment Systems:
Polystick MTS or MTS PLUS followed by Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex
SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with
the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired.
Polystick MTS or MTS PLUS followed by Polystick TU P, TU Plus, TU Max, Tile Pro or Polyflex SAP is allowable for use
under foam -on tile systems. Limits of use are those associated with the top -layer material. This is not a requirement,
but is allowable if a 2-ply underlayment system is desired.
6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex 56 G FR shall be installed in compliance with current Polyglass published
Installation requirements. For use in tile applications:
✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the -Hot Asphalt
applied "Cap Sheet" in.the'Two Ply System" from FRSA/TRI April 2o12 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 201Z (04-12) beneath mechanically fastened tile
roof systems.
6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex 56 G or Elastoflex 56. G FR shall be fully asphalt -applied to the
substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt
with asphalt extending approximately 3/8-inch beyond the lap edge.
6 6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements.
For use in tile applications:
✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet" in the 'Iwo Ply System" from FRSA/TRI April
2012 (04-22) beneath mechanically fastened or adhered tile roof systems (Base Sheet Limited per 5.6.3).
✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI
April 2012 (04-12)-beneath mechanically fastened tile roof systems (Base Sheet Limited per 5.6.3).
Evaluation Report P32060.02.09-R24
NEMO ETC, LLC. F1.6259-1128
Certijlaate ofAuthorkatlan N32455 6' EDITION (2017)FBC NON-HVHZ EVALUATION
Polyglass Roof Underlayments; (954) 233.1230 Revision 24:01/24/2018
Page 13 of 14
i
ONEMOjetc-
6.6.2 Polyflex G or Polyflex G Fit shall be fully torch -applied to the substrates noted In Section 5.6. Side laps shall be
minimum 3-inch and end -laps minimum 6-Inch wide, off -set minimum 3 feet from course to course. Side and end
laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap
edge.
6_7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to
Table 2 herein, and Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counterbattens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used
on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail-
boards, to prevent the sliding and/or damage to the underlayment during the loading process.
6.7.3 Polyglass specifies the minimum cure time after installation of self -adhering membranes and before loading of
roofing tiles is forty-eight (48) hours.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product-
B. MANUFACFURING PLANTS:
Contact the noted QA agency for Information on product locations covered for F.A.C. 61G20-3 QA requirements. The following
d th' s ective hysicalproperties specifications.
plants have qualified products un er elr re p
�. i ". ,. "r> '., T ry•a .
p
SoeciRc"at)on .
xPlent' „ 5. _
Fernley, NV, Hazleton, PA & Winter Haven, FL
Hazleton, PA
Hazleton, PA &Winter Haven, FL
ASTM D1970
M-D 13-0004
ASTM D1970
Polystick MU-X
Elastoflex G TU
Polystick IR-Xe
ASTM D1970 & FRSA/TRI April 2012
Polystick TU Plus
ASTM D3970 & FRSA/TRI April 2012
Polystick TU Max
Tuscaloosa, AL
Winter Haven, FL
ASTM D4601, Type 11
ASTM D226 (physicals)
Polyglass G2 Base
Elastobase, Elastobase P
ASTM D6509
Polyglass APP Base
FRSA/TRI April 2012
Polystick MTS, Polystick MTS PLUS
FRSA/TRI April 2012
Polystick TU P
FRSA/TRI April 2012
ASTM D1970
Polyflex SAP, Pol ex SA P FR
Polystick Dual Pro
ASTM D1970 &,FRSA/TRI April 2012
Polystick Tile Pro
ASTM D6164
Elastoflex S6, Elastoflex S6 G FR
ASTM D6222
Polyflex G, Polyflex G FR
9. QUALITY ASSURANCE ENTRY:
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
. END OF EVALUATION REPORT -
Evaluation Report P12060.02.09-R24
NEMO ETC, I.I.C. FL5259-R28
Certiflcute o)Avthork-dan#32455 bra EDITION NON-HVHZ EVALUATION
Polyglass R000ffUnderlrlayments; (954)233.1230 Revision 24:4 1
Page age of 14 of 14
East coast metals
2301 West 8 cone
Hialeah FL33010
ERFERIOR RESEARCH & DESIGN, LLC.
Crrtllkote oftmhaba W n esSa3
353 CHRISTIAN STREET, UNI17g13
ERD OXFORD, Cr 06478
PHONE: (203) 262-9245
FAX' (203) 262-9243
SCANNED
BY
St. Lucie County
eYdivanan nepen uvcv..............
F 5374-PA
Date of Issuance: 09(03A008
Revision 4:03MA015 .
SCOPEI-::: �
This Evaluation Report Is Issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials In the State of Florida. The dcmamentadon submitted has been reviewed by Robert Nleminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the a Edition (2014) Florida Building Code sections noted herein. ,
OrscuPnom East Coast Metals Channel Metals
IAsisumt Labeling shag be in accordance with the requirements the Accredited CwalRy Assurance Agency noted herein.
CONTINUED CaMPttANCE: This Evaluation Report Is valid until such time as the named product(s) changes, the referenced
duality Assurance documentation thanges, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Meminen, P.E. If the product changes or the
referenced duality Assurance documentation changes. TrinitylERD TeRtfim a complete review of this Evaluation Report
relative to updated Cade requirements with each Code Cycle.
AovEsomEmenr: The Evaluatlon Report number preceded by the words 'TrinitylERD Evaluated' may be displayed in
advertising literature. Ifany portion of the Evaluation Report Is displayed, then Itshall be done in its entirety.
lawEirrose upon request, a copy of this entire Evaluation Report shag be provided to the user by the manufacturer or its
distributors and shall he evallablefor Inspection atthe Job site at the request of the Building Official.
This Evaluation Reportconsisa of pages 1 through 7.
Prepared bit
da�t�'e1.4}
.yt-
3,1 ♦ Ir
Robert J.M. Meminen, P.E.
oU �.
'3 .,,zj° 0.1
eiamnr iiammro. r+an.++p+w+
tn'.+,
Fleddffftbaade0Ko.$sU 6,FAddo erAANtl983
egmi,mw,mmrwmvan.meavm
ramimmen ssmdo nnot h
1. idniryl� does ^ot have• nor does R intend to acquire or will R acquire, a finsmdal interest in any mmpairy manufacturing or
distributing productsit evaluates.
2. TrinirylEROisnotowned, operated orcontmRed by anytempamy manufacturing ordbtnbuting Products Revaluates.
3. Robert Nieminen,P.E. dons not have nor will acquire,a financial Interest in any company manufacturing or distributing productsfor
which dK evaluation reponsam beingissued.
4. Robert to miner, P.E. does not have, nor will acquire, a financial into ust in any odiaentity Invoked in the appal process of the
Product.
S. Thls N a building code evalmdon. Neither TrinitylERD nor Robert Nleni en, P.E. are, in aoy way, the Dedgner of Racord for any
project on which th6 Evaluation Report, or previous versions thereof, bfwas used for pemhding or design guidance unless retained
specifically for that purpose.
(
TRINITY iERD
ROORNO COMPONENTEUAWATION:
L SCDPE:
ProductCategoryr.
Roofing
Roofing Atcessoriasthat omen
Integral Part of the Roofing5ystem
SLh.Ca"rlr
Meals dannet Meals, as
produced by East Coast Metah, have
demonstrated WmPfame
Compliance Staames on East Coast
with the fallowing sections of the panda RuMng Code through
testing inaccuclance With thefa0owing Standards. Comptlanty
issobject to theinaallatfon Requirement, and Umiedlow/Cmnlutow of Usesetforth herein.
L STANDARDS:
Sectio
157
Property
nnTalvtlan,noteHVHZ
Snandoad
FREWN Apm 2012(0412)
2012
151eg1
lnswb 6HOHL
RAS11%119&f20
299S
2533AS22
Sa*UpehRehtw=
TAS201
>� .
.
171LLI
StadcupOhfielbance
SOCCSS11131
1997
S. 'REF1TacEs:
. EYamNatbn
DateEAOIRST6049)
08/23/2413
ERt1QR4049j
StaaupOhRedtanc4
SadcupghBehance
E4273DAM
EC!"015795.12.1441
OZI27AMS
ERo(757E079)
SadcUpRBRestsuaw
Et2ASC5795,12M
ozwrms
10n7/7010
FvddaTECIT517393)
PN(T
TAS 101
TAS 101
S10420111
WJ2710030
ADOL
=70)
PRI
TASIM
ECA'awaZ-0am
EC
O6/13/1008
O4/13/1000
USTS878)
PR1(TSTSR781
Pan(TS15678)
TAS 101
Ift
TAS 101
40542-01
EcMansa I
(101311000
0013AM
PRI
TAS 161
ECM-00802-01
os/73/100e
USTSe78)
Pat RICITI B78)
Fa(6BuIldi
TAS 201
TAS301
Ema4m2-01
ECJF00IApd1
04J23/7008
FIuNaBulldingCPda �
Attxhm4ntRequfamenv
FRSA/RRApA20111OF121
0//2072
1935m
Fladdalaidin80de•NO,HL
AttschanodReputamenv
RAS US, 119 and 220
Eastem"Meah
AOhhawalTesdng(QUA1et0)
MealQaanty
Qualitycontrol
AWCett&aoam
PWdpadonLetter
am.37/31/mil
4. PRODUCTDESCO TION:
41 Hip & Ridge Channel Metal: Pr farmed meal channel
deigned for use as a hip and ridge base towhich mofbles
are bonded in FBC Appmved mof the adhe*&
Hip & Ridge Channel Meal Is avaOable in 119-3/84nch
3/84nth) length by 2S, 3, 3.S, 4, 5, 6 erNfla L3/8•irKh)
heights with L54nch L3/1&bmh) deck -Ranges.
aaadprReaudt and Oesl2n,LLC Elnluall°nNep°nFi07AO.oe.OgR4
fptyfmtee7Auavtaedannml 013740,4
Reyldwt4:03/17/2m5
hge2af7
4.2 Trim lock Channel Metal: Pre -formed metal chimed
designedfor useas a hip and ddgebase towhich roof tiles
are bonded in FBC Approved roof We adhesive. Trim lock
Channel Metal Is chamhaected W its profiled and
perforated er horizontal flange designed to recolve
and allow, foripmedockwkh the ovedyi gtle adhesive.
Trim tack Channel Metal is available in 119.3/84rich L
3/a7 length by 3, 3S, 4, 5 or Wnch L• SA -Inch) heights
with 254nch (+2A64nch) dedo-flarsem
42
Trim Lack Plus Channel Metah Pm -formed metal channel
designed for we as a hip and ddge base towhich roof Was
am bonded In FBC Approved roof tile adhesive. Trim Lock
Plus Channel Metal Is chamcmrhod by Bs profiled and
perfod! to receive
and allowforfor upper horizontal flange e
Interlock with the MrIongt t adhesive
and Its perforated deck flanges, designed for Installation
atop the roof undedaymeat via placement in FRC
Approved roof We adhesive, which flows -through and
Intedoc¢ with the underlying adhesye.
Trim lack Plus Channel Metal Is available in 119.3/84tuh .
L+3/8') length by 3, 35, 4, 5 or &Inch (±3/&Inch) heights
with 7S-Inch I+1/16-Inch) dec-flages.
i TRINITYERD
4A Fast Coast Metals Channel Metalsam fabricated of the following metah:
D Wlvanbed Steel: Mln.o.O g:to.OD2-Inch,ASTMAS53(6.90hmlm331M.
D Qlvalume5mel:Min.0a19±OA024nc4ASTMA792,AZS5,mim3516L
D Aluminum: Min. 0.032±0.001-Indh, ASfM BW% 3003-1114, rem. ll giL
D Stainlm Smel: Min.0A19±(Lon4nd%A5fMA24o/A480,T304,min.35KSL
5. LIMITATION9:
5.1 This Is a building code evaluation. Neither TdnitHERD nor Robert Nlemineo, P.E. are, in any way, the Designer of
Record for any protect on which this Evaluation Report, or previous vmakms thereof, is/was used for permitting or
design guidance unless retained spedOmlly for that purpose.
DaedorRerearrharM Dedgn, ILG aWupbnRepedE10240.53NM4
F15374Rt
4htlpmfeeJAutMdm4mI3rW e4vWon4A3/17/7a1S
PapSof7
TRHTY jERD
S,2 FORNPN2IURSDIC^ON•'
S.= For Hip & Ridge Channel Metal or Trim lads Channel Matti, refer to FBC PAS 11& Umsdng 13, Detail 3; PM 129,
Drawing 12, Detail 3; or RAS 120, Omwa61% Detail 3. For Trim lack Plus Channel Metal, refer to the Installation
Instructions herein.
S22 For HM Imisdktlons, Installations of Hip & Ridge Channel Metal and Trim lark am, prescriptive W RAS 11% 119 and
no, and the data inTables 1Aand7a is supplemental manage prewiptNe afteme ces.
hananstans of Trim Lack plus amitmtted to PwIdds having a ieW and moment resistance (MJ or upRR resistance (F,),
as determined in accordam with RAS 127, not greater than the folkwdng values
Rarer to the tie adhesive manufadumes pubiblecd installation Instructions for edhedw paddy platement deans.
D "INDEPENDENT" paddy placement means each Individual ale is bonded on the Owned Metal in Its own, $ingle
foam paddy; tine head laps are not bonded This method is limited to 2-part tee adhesives. Allowable
performance data below for "INDEPENDENT' paddy placement already has 12 to 1 margin of safety applied to
UldmateperformancL
D 'INTERDEPENDENT" paddy plecamentmeam each lndtddoll toe is horded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the the had lap, or two ides are handed to the Channel Metal using a single
foam paddy. Mineable performance data blow for'INTEROEPENOENr paddy placement already has a 4 to 1
marldn of safetyappuedto ultimateperromranm
TAele1D: prapmraaxcelrswmmns-HPH71NrOatromaNrPAocrrPurUaDTr
' r4talrAoldllmraarTAi6a0YATUmf
Mp/RldleMetei
Tina
AdhaNe
ACamhlapedmmame
MorlientBned
Uplift eased
DOSTar
Menl7vpe
TV&
Pbtemmt
14M01,0
F(&D
Tdmta&"TUm
gW4nked,Gahaama•,
flavor
3Me'1.OpmpawrdFmm
latudeperdeat
95
0a
tnskaus
akowmm�msbadeseseed
accurate
go INAdheduckARA6G
gabooked, Galvalmne•.
civet
am-a4oftaeAdheslee
Interdependent
99
94
Trim Mdt
stiude sated
mvu=te
ITT"
clover
36PFoarnRoctTae
ineerdependem
90.
94
itmmd
aluminum
acserse
Adhesive RTM3
gdadved, Gdvaame•,
davm
Tile
Interdependent
90
84
Tftto&Plus
ahudnamermafesssted
amaeta
AdhesNeRfA-1
aahadted,Gawahane•m
on"
THE BONU'MdTb
anedepeMent
123
117
ldm lurk
steaknsaeel
concrete
Adhesive
Trin, Imk
atuminum
data
omcete
IUBMO-RmfTae
Adhmem
rnMdependent
79
73
galranaed,Gahah,mn•,
clever
IIIEROIm+ROOlve
InkmapaMent
79
73
ltkn lockNm
aluminumorstaaksssaetl
concrete
Adhesive
IfaWante4GaNahone•or
dayor
TCam-nSedSwrmBand
Intedependmt
146
139
Trim Lod[
steadmssted
wmrate
acefTReAdmim
daym
Touch InSwISmentond
atudepeaded
58
54
Trap lark
Mrmaum
mrroete
IteWTaeAdiadse
gahanhed.G4Mhane•,
day or
Toud,filedlmm,94nd
aamependot
Sa
54
Tdmlarkphs
alumaumwsteinkasteel
concrete
ltmfTRandhestm
51ta1bIRlseNdtarld Deslpr, HG EwhadarlRepnRElOt40.a 74-R4
FlS374•R4
etrygmeentAurMemtb„a9sm Rablanm0311712015
Page4of7
` .`TRINIii( ERD
53 FORNON•HVI¢NR15o1CfIDNR
53.1 far Hip 8 RUIP IC100d Metal or Trim lock Chmnet hh" mhr to FRTA/fN Ap1R 2D12(frf•321• FarTrM lam Plus
Channel Metal, mfertotheinslaBa m instructions herein
53.2 Far n,,4m IMtatlations am ranted to Pmlear haft hip and ridge design pressure requirements, detIFMMW in
accordance with Table 1A of RISVM AprR 201210442), Out greater than the following values. Refer to the t9G
adhesWe ma.racturce, published Installation Instruction for acclusake paddy placementdeta[L%
8 °INDEPENDENT" Paddy placement means each hsdtaidual tea Is bonded a the Channel Meal in its own. Cade
fors paddy We had laps are nothanded This method is limited
a2•parttileadhedues. Ag bleperformancedaabdowfar9NDEPENDENNpaddyphcementakeadyhua2
to Icemen ufsdety aVpltedto ultimatePerfarmaone,
8 9MMOEP ouwpaddypiammentmeanseadhir4Wdualtikishoadedaths Channel Mealtnafoampaddy,
and a second Foam paddy hands the Die head bm, or two Was am bonded to the Cannel Metal using a single
foam paddy, Aiharebie perfamu daa below for'INTERDEPMDENP Paddy phcemmd *eadyhos a 4 a 2
.....,.in. !,nr h.,anefied to untmaacerlmoamn.
TM82A:;POe�nn�t+almvMTloh[-Nwr•tMtL1!ffi PumPulttatatr .
. fttolwircworsAttryAurAorAwoml
HwaNPNtaul
Toe
AdhMM
ADawahIIIIII
64
DedP
meal Type
TV"
Placement
Hilwadge
dater
3M"LConponentF am[ad
adep ndeat
169
Channel Meal
PIH M
meoem
TkAdheaMAH•160
PMnhad, Gah iume•,ahwaum or
Bayer
3M^Memponentleam Roof
jae pendent
178
Tdmaek
sainaassual
mmreta
ThAdhadmAH-160
[WankedWNdume•,siumhwmor
dwer
3M^2{amponentFwmNmf
IMsrysndant
178
TdmatkHm
shalasSMI
mnaals
TBeAdhWmAHSW
TAme2Bt PMRMAMUMITAMNS—NO"VHI. PAODTPtACUAW
1dmlAM15310 YAMahmAMYm1
HlpPRIfte i
10o
AdhaM
ADowaale DP[N
fwo
Type
Paammt
Da4n'
Mdd7tpe
idmlackorTrhn
PMnked,WMtume•,dumhwm er
Bator
3Me'1•Canpaamtfeam Bear
Idwdepeadmt
98
IokPlus
sta'vderssteel
C to
7BoAdhdlraAH•160
galwohod,WMWme`orsaedm
dryer
30^Foam Poeflide Adhedse
Inodeendmt
late
Tmn loch
steel
woaete
lICA3
doter
3M^Poem Rmf79eAdheshe
Inedependent
93
Tdm adC
aluminum
ronaea
RTA•1
gaMnhad,GeMlume•,duminumot
dryer
3M^Fomh RootTikAdhesMe
Interdependent
93
TIt taaplus
saidewsreel
matte
RTA•1
PNanhed,6alvdmne•wdaWess
Bryon
Td OOM-sworweAdhesM
Interdependent
151
Tdm lark
sod
mmrea
fa'yor
TREBDIaTRa lPle Adhesiae
Interdependent
a1
Was ark
aimnaum
mnmm
Tdm
gaM° 'GaNalume•,aluMmonar
day or
TllgeDND"RoadfReAdheshe
madependmt
at
takPiw
st3inimsted
mnaea
Wlvahene•mshhhiess
Craver
Teuel'niseal5torm9daRod
Mtedependent
148
tHm LockgaMdted,
seal
mnaea
Th Adhadm
dryer
Tads'n3ealAmmeandPod
toused pendent
fd
Tdmlodt
Alumimtm
rnnnehe
ig.Mhasthe
PMnlad Wimyme•,alumahwnar
Touch n3esiNmm19mCm8and Four
InterdepmdMn
61
Tdm adCPaa
naNkasad
9derlmpeseamhandpestgn,ttC Evslmtlan ggpoteg102aaD606A4
Fe6376 Ra
[br8lmredAudodCvdmNaF RMslan4��17/1a15
PaP3o17
�TWNITYIERD
6. 11WAWTIOht
6.1 The roof dock shall be minimum 1"24nch plywood (no"VIR( or minimum 151 finch plywood (HVW) attached In
accordance with FBC Chapter 23 to the sa6sfa W on of the AM.
62 Nip & Ridge Channel Metal and Tdm Lock Channel Metal shall be Installed using min. 12 &L x Wnch Imhg x3184nch
head diameter galvanited annular ling shank tags spaced 6•inch o a along both deck46anges. Fasteners shag be
FOCCRRASS 118 Umwiinngg 33 Detai�RASS U9edge f DmuBn Detail 3;ar RAS 12each deck-fiange, set In a bed 0, Drawing 35lastic roof m , Detail 3-rFBC NVFf{refer to
63 Trim Lock Plus Channel Metal shag beinstalled stop the Approved mofundedayment In continuous 24nch wide ribbons
of tile adhesive centered beneath each l.5-inch wide deckilange. Place the Trim Lock Plus Cannel Metal into thewet
adhesive and allow has Wt-VP P&I'VO IR921131han of roof tiles.
VlewoFPolysetAHl6o PlacementforTrlm LockPlus Channel Metal butobedaa
6.31 it b critical that the bond between the Trim Lack Plus Channel Metal, the file adhesive and the underlayment is not
disturbed prior to or during placementofthe Was t9eL
63.2 Approved mhderlxyments arc the codified 3oAar system or other FBC Approved real underiayments Rising approved
use of the subject file adhedve.
DanbrRasearch and Dena, LtC. avaluadan Report Fle24aaaaait4
O,tlftahafAVMvrYhbnelSat RSi7aR4
beddenarW/2TAGIS
Paae6ef7
TRINITY i ERD
6A ine shall be Installed stop the blished
installation Instructions, subject to the limitations outnd Metal In lined Innce Section Sthe ihemi . The exposed edso shalle adhesive manuFacturar's e packed and
pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (0442) or RAS
118, RAS 119, RAS320 requirements.
Hip / Ridge THE
Tile Adhesive
Trim Lock Plus
Moam or Weather Block
Adhesive
Tile Adhesive
Wewof Trim Lock Plus Channel maullnstallatlon after Weath"Bledred
6A.1 Channel Metal shall be free of dud,debris, ails or other bond -breaking substance prier to placement of adhesive.
7. BUILDING PERMIT REQUIREMENTS:
As required bythe Building official erAuthority Navinglurbdictian in order to properly evaluate the Installation of this product.
B. MANUFACTURING PLANTS:
Contact the named OAndtyfor manufacturing faulitiescovered by FJLC. Rule 61G20-3 OA requirements.
9. QUALITY ASSURANCE ENNiy:
Architectural Toting. Inc.—QUA1891; (717)764-7700
-ENOOFEVALUATION REPORT -
ExtedarResoorchandoeshALM EvaluationRepoftElOMMALO M
ELS376aA
outwW aa7Audw herbal" RevhlonermMADIS
Page7a17