HomeMy WebLinkAboutPRODUCT APPROVAL - NAILSTRIPPalm City, Fl. 34990
Compliant with Florida Building Code 2017 (6th ad.)
Compliant with Florida Product Approval Rule # 61G20-3 ST LUCIE
Compliant: Keystone Certifications auILREVIE
FOR COM
DATE 17,► I /0 l //
Product: I" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2 PLANS AND P • MIT
OR
Yield strength: 50 ksi min.; Attached to min.15/32" I MUST KEPT JOB
Bt WOO or NP Y O INSPECTION WILL BE MADE
Wood Deck w/ OA2 specific gravity with 16" Coverage (Max.
Rib Height 1"
Corrosion Resistant Compliant: FBC Sec.1507.4.3 SCgN/�
Fastener 1: #10 x V (min.) Pancake Head Wood Screw to penetrate 3/16" (min.) thru Sf 4Uc ey Fp
bottom of support. ir? CoU
Adhesive/Sealant : Bostik 915" Chem -Chalk one component, polyurethane adhesive with n/Y
3/16" continuous bead application along base of male rib vertical flange at each panel
seam. THESE PLANS AND ALL PROPOSED WQR:;
Underlayment: To be compliant with FBC Sec 1507.1.1 ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
Slope: Shall be in compliance with FBC Sec.1507. WAY NE NECESSARY IN ORDER
COMPLY WITH ALL APPLICABU
Install Details: Table A _Allowable Loads_
_ METHOD.1
DESIGN PRESSURE'
86 PSF Mainfield
-9725 PSF Perimeter
FASTENER SPACING
6" O.C.
6' O.C.
SEAM ADHESIVE
Not required
3/16' continuous bead
_
see detalLs
Reference Data: ARCW CruaTESTING, INC. TST I1111:1527
UL S80-06 & UL 1897.04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2
EQUIVALENCY 1IL1897-041s egmvWent to Test Standard UL1897--12. „•pe$ugp Pressyre rtt4l9%R .Of 5dfety,A_.
Certificate of Independence:
Locke Bowden, P.E. does not have, not wig acquire a linancal l9poaltinpy,tompanV manufacturing or distributing products
under this evaluation. D '13Gyy,. Li,,
Locke Bowden, P.L Is not owned, operated, or contrail e�' Y� In ordistrihuting products under this
report. %%•%� �' _
TO
CODES.
•Gtzpri' .-
x seal GONGEALpO FggiENERS ORAiTACHMENT:
10 STATEOF :,y`� ' ARE THE RESPONSIBILITY OF THE
LORID ,
. ..
'`'h„' F t• ' CONTRACTOROFRECORD
'ONAt Em k'••'
amm
Limitations:
1. Undertayment to be compliance wdh current Florida Building Code (FBC)2D17 6°'ed-
2. Mnimum slope to be compliant wM Florida Building Code 2017 Vied., and perwith Manufacturer's installation reference.
3. Products are compliantfor State of Florida product approval per Rule 61G203. Compliance Method: l-D
4. Engineering analysis for "project specifc approval by boat authodeswfiurisdiction is alovred by other registered ergcieers.
5. Fire classification is not W of this acceptance. Sheardiaphml;m values are outside this report
6. Support framing In compliance w1FBC 2017 61, ad., Chapter22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural
Loading.
7. This report does not Imply warranty, Installation, recommended product use outside of this report
FL 17022.5 1.0 Nail Strip (26GA Steel),1611 Wide Roof Panel - Details
16"
--I
Panel Profile
16" o.C.
- -
3/4"
1
Deck:
-15/37 or greater Plywood, or
- Wood plank
Snap Lads
Apply Mir Bead Bostic 915w Sealant
ContinuousAlong Male Rib Vertical Flange
Fastener
910 x 1"Mn. per Table W
Pancake Head Wood Screw
(Typical Fastening Pattern Across Width)
r,
101
FL 17022.5 1.0 Nail Strip (26GA Steel),16" Wide Roof Panel -Details
GNnnn�
-156Z or greater Plywood, or Apply 3H6" Bead Bostlk 915^' Sealant
- Wood plank ContlnuousAlong Male Rib Verfical Flange
(Refer ID Table W)
Isometric View