Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutNOASDEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
RFcervz
DEC 2 8?01B
PernNttin MIAMI-DADE COUNTY
St. ��go
a Cod ty entPROD 80 SW 6 Street, Room 208
SECTIONCT CONTROL
Miami, Florida 33175-2474
COPY T (786).miamid F (786) crmo v
NOTICE OF ACCEPTANCE (NO j I � www•miamidade.eov/economy
Petersen Dean Roofing and Solar Systems, I L
1011 Fairfield Drive
West Palm Beach, FL.33407 CONCEALED FASTENERS ORATrACHMENTS SCANNED
ARE THE RESPONSIBILITY OF THE BY
SCOPE: CONMCTOR OR RECORD St. Lucie County
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Englert Series 2000 Aluminum Roof Panel
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building OT* PLANS AND ALL PROPOSED WORK
ARE RUBJECTTO ANY CORRECTIONS
This NOA renews NOA# 10-0324.04 and consists of pages 1 through 5. REQUIRED BY FIELD INSPECTORS THAT
The submitted documentation was reviewed by Alex Tigera. MAY BE NECESSARY IN ORDER TOCOs PLY lh'ITH ALL APPLICABLE CODES.
ML4MIDADECOUNTY I��•-~���I NOA No.: 15-0223.11
�"V Expiration Date: 04/16/15
ST. LUCIE COUNTY ING D S Approval Date: 04/]6/15
REVIEWED FORMPLIANC Page 1 of5
PLANS AND PERMIT MUST BE KEP'
SITE OR NO INSPECTIONS) WILL
11 t4
ROOFING ASSEMBLY APPROVAL:
Category:
Roofing
Sub -Category:
Non -Structural Metal Roofing
Material:
Aluminum
Deck Type:
Wood
Maximum Design Pressure
See Table A
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product
Dimensions
Test
Product
Specifications
Description
Series 2000
1= various
TAS 110
Aluminum, preformed, standing seam
w = 18"
TAS 125
panels.
Thickness 0.040"
Min.
Yield Strength: 17 ksi.
Series 2000 Clip
min. 0.048"
TAS 114
Corrosion resistant, formed, steel clips for
3'/2" long x
metal panel installation.
13/4" high
Trim Pieces
1= varies
TAS 110
Standard flashing and trim pieces.
w = varies
Manufactured for each panel width.
Thickness 0.040"
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report Date
Architectural Testing, Inc.
01-32796.01
TAS 100 Sep. 1998
Architectural Testing, Inc.
01-46070.02
TAS 125 10/23/03
ASTM E 8
Hurricane Test Laboratory, LLC.
0155-0404-04
TAS 125 04/16/04
NOA No.: 15-0223.11
Expiration Date: 05/19/20
Approval Date: 04/16/15
Page 2 of 5
APPROVED ASSEMBLIES:
System: Englert Series 2000 Aluminum Panel
Deck Type: Wood, Non -Insulated
Deck Description: New Construction 19/32" or greater plywood or wood plank.
Slope Range: 2": 12" or greater
Maximum Uplift See Table A below
Pressure
Deck Attachment:
In accordance with applicable Building Code, but in no case shall it be less than 8d annular
ring shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick
(Minimum15/32"). The above attachment method must be in addition to existing
attachment.
Underlayment:
Minimum underlayment shall be a ASTM D 226 Type II installed with a minimum 4" side -
laps and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and
1'/d' annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c. in
the field of the roll. Or, any Miami -Dade County Product Control Approved underlayment
having a current NOA.
Fire Barrier Board:
Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
the assembly. See Limitation # 1.
Valleys:
Valley construction shall be in compliance with Roofing Application Standard RAS 133
and with Englert's current published installation instructions.
Metal Panels and
Install the "Series 2000 Panel' and accessories in compliance with the current published
Accessories:
installation instructions and details in Englert's Installation Manual. Flashings,
penetrations, valley construction and other details shall be constructed in compliance with
Roofing Application Standard RAS 133. Male leg of snap seam shall be caulked with a
minimum '/a" bead of elastomeric construction sealant prior to installation of female leg of
panel.
Panels shall be installed with galvanize steel clips (3'/2" long x 2'/2" wide x 1%" tall),
attached to substrate with (2) two corrosion resistant #10-16 self -tapping pancake screws of
sufficient length to penetrate through the sheathing a minimum of 3/16'. Clip fastening shall
start 3" from panel end and shall be at maximum spacing as described below in Table A.
TABLE A
MAXIMUM DESIGN PRESSURES
Roof Areas
Field
Perimeter and Corner'
Maximum Design Pressures
—70 psf
—123.5 psf
Maximum Clip Spacing
24" o.c.
8" o.c.
1.. Extrapolation shall not be allowed
NOA No.: 15-0223.11
Expiration Date: 05/19/20
Approval Date: 04/16/15
Page 3 of 5
SYSTEM LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. ' The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters,
and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced
pressure zones (i.e. perimeters, extended comers and comers).
3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in
Roofing Application Standard RAS 133
4. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement:
"Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen
below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or model.
5. All products listed.herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the. Florida Administrative Code.
6. Panels may be jobsite roll formed with machine model #0880909 from Englert Inc.
NOA No.: 15-0223.11
Expiration Date: 05/19/20
Approval Date: 04/16/15
Page 4 of 5
1 3/4"
3/8"
1 3/4"
PROFILE DRAWING
SERIES 2000
18"
PANEL
1/2"
END OF THIS ACCEPTANCE
1 5/8"
NOA No.: 15-0223.11
MIAMI•DADE COUNTY Expiration Date: 05/19/20
Approval Date: 04/16/15
Page 5 of 5
RECEIVED
MIAMF
c
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
DEC 2 8 2818
Permitting Departnt MIAMI-DADE COUNTY
St, Lucie COORy PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786)315-2590 F (786) 315-2599
www.m iam idade.eov/economy
GAF H LE COPY SCANNED
1 Campus Drive BY
Parsippany, NJ 07054 I 2, t ri= � Q�12 t 1 f1� St, Lucie County
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: VersaShield® Fire -Resistant Roof Deck Protection and VersaShield® Solo— Fire -Resistant
Slip Sheet
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed'and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 14-1022.26 and consists of pages 1 through 3.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 16-1216.02
Expiration Date: 02/07/22
Approval Date: 02/02/17
Page 1 of 3
Y..
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: Fiberglass
SCOPE:
This acceptance is for VersaShield® Fire -Resistant Roof Deck Protection (a.k.a "VersaShield® Underlayment") and
VersaShield® SoIoTM Fire -Resistant Slip Sheet (a.k.a "VersaShield SoIoTM"), as described in this Notice of Acceptance,
for use with approved prepared roof assemblies. Designed to comply with the Florida Building Code and the High
Velocity Hurricane Zone of the Florida Building Code.
PRODUCT DESCRIPTION:
Manufactured b
Applicant
VersaShield® Fire -
Resistant Roof Deck
Protection
Test
Dimensions Specifications
Product
Description
42" x 100' rolls ASTM D 226 Non -Asphaltic fiberglass -based underlayment
Type II and/or fire barrier.
VersaShield® SoIoTM 72" x 166.7' rolls UL790
Fire -Resistant Slip Sheet 36, x 166.7' rolls
MANUFACTURING LOCATION:
1. Conover, NC
EVIDENCE SUBMITTED:
Test Agency Test Identifier
PRI Construction Materials
Technologies
Underwriters Laboratories Inc.
GAF-270-02-02
GAF-748-02-01'
ELK-063-02-01
99NK45831
1ONK11990
R19254
08CA37926
08CA49140
Non -Asphaltic fiberglass -based slip sheet and/or
fire barrier.
Test Name/Report
ASTM D 226
ASTM D 226
TAS 100
UL790
UL790
ASTM D 226
UL790
Date
11/15/10
12/12/16
09/27/01
03/21/00
05/18/11
09/13/01
09/23/09
INSTALLATION:
1. VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® SoIoTM Fire -Resistant Slip Sheet shall be
installed in strict compliance with applicable Building Code.
2. VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® SoIoTM Fire -Resistant Slip Sheet shall be
installed with a minimum 4-inch head lap in a shingle layer fashion.
3. VersaShield® Fire -Resistant Roof Deck Protection shall be mechanically fastened with approved fasteners in
compliance with Florida Building Code 1518.2 when used in lieu of a code prescribed ASTM D 226 Type II
underlayment.
APPROVED
NOA No.: 16-1216.02
Expiration Date: 02/07/22
Approval Date: 02/02/17
Page 2 of 3
LIMITATIONS:
1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire
ratings of this product
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.
3. VersaShield® Fire -Resistant Roof Deck Protection shall not be left exposed as a temporary roof for longer than 30
days of application. VersaShield® Solo TM Fire -Resistant Slip Sheet shall not be left exposed to the weather.
4. VersaShield® Fire -Resistant Roof Deck Protection and VersaShield® SoIoTM Fire -Resistant Slip Sheet are a
component used in roof assemblies. Roof assemblies are approved under specific assembly Notice of Acceptance.
5. VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® Solo- Fire -Resistant Slip Sheet may be used
with any approved roof covering Notice of Acceptance listing. VersaShield® Fire -Resistant Roof Deck Protection
or VersaShield® SoIoTM Fire -Resistant Slip Sheet may be used as a component part of an assembly in the Notice of
Acceptance. If VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® SoIoTM Fire -Resistant Slip Sheet
is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product
Control Department for approval provided that appropriate documentation is provided to detail compatibility of the
products, wind uplift resistance, and fire testing results.
6. VersaShield® Fire -Resistant Roof Deck Protection and VersaShield® SoIoTM Fire -Resistant Slip Sheet are a non -
asphaltic underlayment that may be used as a fire barrier for prepared roof assemblies. For fire classification of
specific roof assemblies using VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® SoIoTM Fire -
Resistant Slip Sheet refer to a current Approved Roofing Materials Directory for fire ratings of this product.
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
LABELING:
All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and
state of manufacturing facility, yellow line to identify the ASTM Standard designation or logo, and the following
statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as
shown below.
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by Building Official or Applicable building code in order to properly evaluate the
installation of this material.
END OF THIS ACCEPTANCE
NOA No.: 16-1216.02
Expiration Date: 02/07/22
Approval Date: 02/02/17
Page 3 of 3
Total Line Lengths:
Length Diagram Ridges = 72 ft
Shaded areas should be verified Hips = 142 It
30
:
EXTtNQE6CdVERAGLt
Valleys = 38 It Flashing = O ft k.-
Rakes = 0 It Step flashing = 0 It
Eaves = 285 it Parapets = 0 It
Y
LE COP pe��,
S``4el �Q.uCI °7a pa.
H7I
/ 37
4
,I6
G
is
S9�:)
J E
N + s
w
Note: This diaqram contains seqment lengths (rounded to the nearest whole number) over 5.0 Feet. In some cases, segment labels
have been removed for readability. Plus siqns preface some numbers to avoid confusion when rotated (e.q. +6 and +9).
Disclaimer: This report was produced using EagleView Extended Coverage Technology, Due to a variety of reasons Including, but
not limited to: tree coverage, poor Images, low photo resolution or other blockages; this report DOES NOT offer an accuracy
guarantee. EagleView recommends that anyone using this report field verify the yellow -shaded sections.
Report' 25877525 ®ZW&3030 Foyle Vltw Tefimtyk9�0K. MOp4pm(Rry BItbIWtlW�fgp.-NI G9Bm RGLrvM-proY�M by Eumpdn Pa[mt AgAloL'on No.lOt611933
-raxv� M ae w more W U.S, pMat Ws.O,B/B,436y 0,145,5/0; 8,U0,090; B,X9,1R; 8,S15,I15; 0,015,9N; 9,U5,TJ]; B,6T1,961; 9519,F6B; B,B1B,770;
E<w\iww Claim: 27 B,59;BB6� 9,219,50919,319,J49; 9,599pfi6. W V IhhMa PoMi�p.
�4
Petersen -Dean Inc Page 4
r r '
12/6/2016
32616_35937_1.jpg(512x384)
FILE COPY
fi�18Q,--© y86
https://w.paslc.org/ImageSketches/sketch/32/32616_35937_1.jpg 1/1