Floor Plan
scale: 1/4" = 1'-0"
Proiect Data
Project Name: Beebe Residence
Street Address: XXXX Cody Lane
City: Ft. Pierce
County: St. Lucie
State: Florida
Scope of Work
New One level CBS
Single Family residence
Design Loads
Roof Live Load: 30.0 p.s.f.
Wind Speed: 160 MPH
Wind Importance Factor: 1.0
Building Category: II
Wind Exposure: C
Internal Pressure Coefffcent:.18
Structure Designed: Enclosed
Soil bearing capacity: 2000 p.s.f.
Building Data
Occupancy Type: Group R
Construction Type: V
Number of Stories: One
Project Area: 2336 s.f.
Building Code
2017 Florida Building Code: Residential
2014 National Electrical Code: NFPA 70
Area Tabulation
Living:
1768
Porch:
408
Entry:
160
Total:
2336
Total Cubic Volume: xxxx
Climatic & Geographic Design Criteria
Weathering: Negligible Termite Area: Very Heavy
Flame Spread Index & Smoke Developed Index
Insulation Flame Spread: Not to exceed 25
Insulation Smoke Developed Index: Not to exceed 450
Wall Finishes: Not greater than 200
Ceiling Finishes: Not greater than 200
Spray Foam
Insulation-
9'4"-�$-- T.O.B. - — -
1/2" d.w
1 x 4 p.t.
Firestop
One Course Perimeter
Beam with (1) #5 Rebar
Filled with Grout
1 x 2 p.t. furring
strips 24"o.c. ---�
with R4.1 Foil
insulation
ire" d.
#5 vert. relha> in
grout filled cell
See Floor Plan
for Locations
4" 3000# Fibermix Conc.
on .006 Vapor Bearier on
Clean, Compacted, Termite
Treated Fill —\
F.F.E.
(2) #5
Rebar
Gti
/-y
M
�
C)
w
w
Q�
a
�
'7.
•C�
~
U
•,.'may
Z
4
�
U
U
W
d
Q
�
C
W
Ga
C7
`L/
M
FDOH in St. Lucie County
Environmental Health
Site Plan Approved for Construction
Supersedes All Previous Site Plans for
OSTDS# 6.5r,I1 ,14q1 &Well#59-�4433
Date: h /0 4
Reviewbr:if" 141
�
5V Metal Roofing
over 30# Felt on
19/32" c.d.x. plywood fastened
as per nailing schedule
Pre Engineered Wood
Roof Trusses 24"o.c.
Shop Drawings by
Others
See Connector
Schedule
/ 12 2x4p..t.
6� Cont.
2 x 4 24"o.c.
Alum. Drip Edge
r
O
2 x 6 Fascia
w
Alum. Wrap
U
Soffit Over
z
W
oStucco
High Ribbed Wire
Q
T-0^
Lath
vs
Install one layer of 15#
felt to framing prior to
•�
installing wire lath
U
8x16x8
v
CMU Typ.
Q
3�
W
"4
�
�
Light Textured
Stucco Finish
Z
rn
#5 Vert. Rebar with
10" Hook and 30"
Lap. Tie to Vert.
Rebar In Cells
,o I Grade
Typical Wall Section
drawn
s.l.
checked
s.l.
date
8/28/18
scale
as noted
job number
18057
sheet
A-1
FILE COPY
a
E
DEC 2 6 ?V
Lucie County, Permitting
tSti!!illlki''"ua07 apnl '15
8W 8 9 310
G3AI332a�d
Floor Plan
scale: 1/4" =1'-0" �`��
Project Data
Building Data
Project Name: Beebe Residence
Occupancy Type: Group R
r-4
Street Address: XXXX Cody Lane
Construction Type: V
H
00
City: Ft. Pierce
Number of Stories: One
County: St. Lucie
Project Area: 2336 s.f.
State: Florida
w
Scope of Work
Building Code
z
New One level CBS
r
2017 Florida Building Code: Residential
L7
0
�
Single Family residence
2014 National Electrical Code: NFPA 70
Cn
�
Design Loads
a�
N
Area Tabulation
Q
a
Roof Live Load: 30.0 p.s.f.
d
Wind Speed: 160 MPH
Living: 1768
Wind Importance Factor: 1.0
Porch: 408
Building Category: II
Entry:
Ent 160
t�
Z
Wind Exposure: C
r l
W
Internal Pressure Coefficent:.18
Total: 2336
V
Q
Structure Designed: Enclosed
_
Soil bearing capacity: 2000 p.s.f.
Total Cubic Volume: xxxx
W
0
�
�
o
Climatic & Geographic Design Criteria
Weathering: Negligible Termite Area: Very Heavy
Flame Spread Index & Smoke Developed Index
Insulation Flame Spread: Not to exceed 25
Insulation Smoke Developed Index: Not to exceed 450
Wall Finishes: Not greater than 200
Ceiling Finishes: Not greater than 200
W Metal Roofing
over 30# Felt on
19/32" c.d.x. plywood fastened
as per nailing schedule
Pre Engineered Wood
Roof Trusses 24"o.c.
Spray Foam
Shop Drawings by
Insulation
Others
See Connector
Schedule
12 2 x 4 p..t. 2 x 4 24"o.c.
Q6 Cont.
9174tt_ T.O.B. - --- -
� i Alum. Drip Edge
1/2" d.w.
-
1 x 4 p.t.�
ii 2 x 6 Fascia
Firestop
Alum. Wrap
U
G)
One Course Perimeter
ii ; ;„ Stucco Soffit Over
W
o
Beam with (1) #5 Rebar
n Hiagdh Ribbed Wire
Q
W
Filled with Grout
ii T-0"
~
Install one layer of 15#
felt to framing prior to
installing wire lath
'
1 x 2 p.t. furring
¢
U
strips 24"o.c.
;1
with R4.1 Foil
ii
h
Ei
insulation
C� Typ,
w
a
1/2" d.
it
W
+'
#5 vert. rebar in
filled
Light Textured
I
II Stucco Finish
grout cell
See Floor Plan
it
" for Locations
4" 30004 Fibermix Cone.
on .006 Vapor Bearier on
Clean, Compacted, Termite
Treated Fill —\
F.F.E.
(2) #5
Rebar
a
0
M
1'-6"
#5 Vert. Rebar with
10" Hook and 30"
Lap. Tie to Vert.
Rebar In Cells
�o I Grade
Ty-pical Wall Section
drawn
s.1.
checked
s.l.
date
8128/18
scale
as noted
job number
18057
sheet
A-1
I
/Sia- - 09457
FILE COPY
Project Data
Project Name: Beebe Residence
Street Address: XXXX Cody Lane
City: Ft. Pierce
County: St. Lucie
State: Florida
Scope of Work
New One level CBS
Single Family residence
Design Loads
Roof Live Load: 30.0 p.s.f.
Wind Speed: 160 MPH
Wind Importance Factor: 1.0
Building Category: II
Wind Exposure: C
Internal Pressure Coefficent:.18
Structure Designed: Enclosed
Soil bearing capacity: 2000 p.s.f.
Building Data
Occupancy Type: Group R
Construction Type: V
Number of Stories: One
Project Area: 2336 s.f.
Building Code
2017 Florida Building Code: Residential
2014 National Electrical Code: NFPA 70
Area Tabulation
Living:
1768
Porch:
408
Entry:
160
Total:
2336
Total Cubic Volume: xxxx
Climatic & Geographic Design Criteria
Weathering: Negligible Termite Area: Very Heavy
Flame Spread Index & Smoke Developed Index
Insulation Flame Spread: Not to exceed 25
Insulation Smoke Developed Index: Not to exceed 450
Wall Finishes: Not greater than 200
Ceiling Finishes: Not greater than 200
Spray Foam
Insulation
T.O _B_ - — -
1/2" d.w.
1 x 4 p.t.
Firestop
One Course Perimeter
Beam with (1) #5 Rebar
Filled with Grout
1 x 2 p.t. furring
strips 24"o.c.
with R4.1 Foil
insulation
1/2" d.
#5 vert. rebar in
grout filled cell
See Floor Plan
for Locations
4" 3000# Fibermix Cone.
on .006 Vapor Bearier on
Clean, Compacted, Termite
Treated Fill —�
0.00'- F.F.E.
Floor Plan
scale: 1/4" — P-0"
(2) #5
Rebar
CC3
U
U
U
r�
v 1
FDOH in St. Lucie County
Environmental Health
Site Plan Approved for Construction
Supersedes All Previous Site Plans for
OSTDS # -5F-(W8J44N & Well # -28J 3
Date:11 la
Revie r.
5 V Metal Roofing
over 30# Felt on
19/32" c.d.x. plywood fastened
as per nailing schedule
Pre Engineered Wood
Roof Trusses 24"o.c.
Shop Drawings by
Others
See Comiector
Schedule
/ 12 2x4p..t.
6 Cont.
2'_0"
8x16x8
CMLJ Typ.
2 x 4 24"o.c.
Alum. Drip Edge
2 x 6 Fascia
Alum. Wrap
Stucco Soffit Over
High Ribbed Wire
Lath
Install one layer of 15#
felt to framing prior to
installing wire lath
Light Textured
Stucco Finish
�i #5 Vert. Rebar with
10" Hook and 30"
Lap. Tie to Vert.
I!; Rebar In Cells
o I Grade
Typical Wall Section
O
w
�
W
U
o
Q
�
^,
w
O
W'
U
w
�
i-i
�
a
�
rss
z
Un
dra"
s.l.
checked
sL
date
8/28/18
scale
as noted
job mm,ber
18057
sheet
A-1
Ln
7t
00
r
N
U
U
w
G
z
II i
w
10
9
K
LEGEND & ABBREVIATIONS
A
ARC LENGTH
A/C
AIR CONDITIONER
BM
BENCHMARK
C
CALCULATED FROM FIELD MEASUREMENTS
C/L
CENTERLINE
CM
CONCRETE MONUMENT
CONIC
CONCRETE
DEG OR
DEGREE
ELEV
ELEVATION
FFE
FINISHED FLOOR ELEVATION
FND
FOUND
ID
IDENTIFICATION NUMBER
IP
IRON PIPE
IR
IRON ROD
IRC
IRON ROD & CAP
LB
LICENSED BUSINESS
LS
LICENSED SURVEYOR
M
MEASURED DATA
MON
MONUMENT
N&C
NAIL AND CAP
NAVD
NORTH AMERICAN VERTICAL DATUM
NGVD
NATIONAL GEODETIC VERTICAL DATUM
NO OR #
NUMBER
NTS
NOT TO SCALE
CHIP
OVERHEAD UTILITIES
ORB
OFFICIAL RECORDS BOOK
P
PLAT DATA
PG(S)
PAGE(S)
PLS
PROFESSIONAL LAND SURVEYOR
POB
POINT OF BEGINNING
POC
POINT OF COMMENCEMENT
PRM
PERMANENT REFERENCE MONUMENT
PSM
PROFESSIONAL SURVEYOR AND MAPPER
R
RADIUS
RLS
REGISTERED LAND SURVEYOR
R/W
RIGHT-OF-WAY
©
WATER METER
&
AND
®
AT
A
DELTA
0
UTILITY POLE
RECORD SURVEY
LOCATED IN SECTION 5, TOWNSHIP 35 SOUTH, RANGE 39 EAST
SAINT LUCIE COUNTY, FLORIDA
FND 4X4 CM
PRM LS 1192
I �Ie
I 01
I N
O
oI
O
I co
I
-
I
o �
o I EXISTING
CS
SEPTIC x E 3,8
x 24
LOT 3
o OCCUPIED
FFE = 24.9'
II
0< 23.7
EXISTING
G
WELL
i T Lill
a x 3.35'
3 .00' 22,8 S 89°25'25- E x
-
x-x-(x -x -X
1 5'F"ARkF64C-t-x- -" -x -"
SET % IRC 22,9 23,5
3 j LB # 7903
YI 0 0 23.8 x a
Qj IQ � x
O 25,8
194J'
L y ,z.00•
o
oI is 'a LOT 4 N
�I O VACANT o 0
1� x
123.3 195.1'
�z.00•
I I O
o I x PROPOSED
25.0 MINIMUM
23,5 x FFE = 24.3'
I h
23,8 23.2 �n
39'.00' 1 lof_
FR NO
I ~ I I
I I I
� I I
I I I
� I I
I I
I I I
22.8
I
I I
I
I
I
300.00'
S 89025'25" E
® 22,9
LOT
OCCUPIED
FFE = 25.5'
I I
x 24.9
22.1\II 20.6
�C x 21.7
FND % IRC 122.27 2 .32 I
300.00, LS # 4363 . 2n n � 22.21
FIND RAILROAD SPIKE
NO ID
FND NAIL & DISK
NO ID (BENCHMARK)
ELEVATION = 22.36'
00 I e I
� O
N
cv o W O
0
�o 0
34.00' O �• I
0 � c 8.00' 51.2' O I
2QU.
u~i ma N C.)c 21,9 2,5 11 X 22,5
) 11 51.0' x 21,
W�SIOo• L0
20.8 22,48
34.00,
O
N ` O
u�
FND NAIL & DISK
FND % IR I 2,81*--
NO ID
22.0/ \21,8
x 24.8 I 21.5
25,5z
x 23.8
24,3
EXISTING
SEPTIC
I
O
C
N
0
O
y NO /D (BENCHMARK)
/ ELEVATION = 22.82'
32.8
I
I
I I
FND RAILROAD SPIKE
-----_-_----__-_ 30.00' NO ID (BENCHMARK)
ELEVATION = 22.97'
V .E
Z
a
o
M
0
a
a
w
x
n
Lij
N
RECEI
D
m
O
M
2JAN
LL
2 8
20
Z
N
Z'
v
_p
Permitting D
a
ment
}
Z
y
LU
W
0
�J
4
St. Lucie
u
ty
O
0
a
U.
}
�
w�>
\WWz
0
/
>
to
LL
,y'
FCj)
t0
Z
=V/w
"0
4
vs
.j
to
d
Zw
=>
oD
JOB=on
0
Lu
N
A1A
Z
a
N
ti
O
LL
Z
W
Q
Q
IL
J
LL
"
Go
00
a
Z
O
a
LOCATION MAP
NOT TO SCALE
STREET ADDRESS
UNASSIGNED CODY LANE, FT. PIERCE, FL. 34945
LEGAL DESCRIPTION
LOT 4, BLOCK B, COUNTRY LIVING ESTATES, UNIT 1, AS PER
THE PLAT THEREOF, RECORDED IN PLAT BOOK 18, PAGES 13
OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA.
r
GENERAL NOTES
1. THE BEARINGS SHOWN HEREON ARE BASED UPON THE
a
CENTERLINE OF CODY LANE, AS RECORDED IN PLAT BOOK 18,
PAGE 13, PUBLIC RECORDS, ST. LUCIE COUNTY, FLORIDA, HAVING
A BEARING OF S00'40'20"E.
G
000
Luxe
2. FLOOD NOTE: BY GRAPHIC PLOTTING ONLY, THIS PROPERTY
aao
IS IN ZONE "X", ACCORDING TO THE FLOOD INSURANCE RATE MAP,
O
a=`=
COMMUNITY PANEL NO. 12111 C 0155 J, EFFECTIVE DATE
-0-6FEBRUARY
16, 2012. THE EXACT DESIGNATION CAN ONLY BE
Ci
<=
DETERMINED BY AN ELEVATION CERTIFICATE.
Z
oo
oza
3. ALL ABOVE GROUND FIXED IMPROVEMENTS, IF ANY, HAVE
BEEN LOCATED AND SHOWN HEREON.
0
�oN
Co
W
Z LL W N
4. THE SURVEYOR HAS NO KNOWLEDGE OF UNDERGROUND
;t U
z z0,0
oz
FOUNDATIONS WHICH MAY OCCUPY LANDS OF OTHERS.
O W
oz
~W�
�wo>
5. UNDERGROUND UTILITIES AND UTILITY SERVICES HAVE NOT
0)Z�'
BEEN LOCATED ON THIS SURVEY, EXCEPT AS SHOWN.
U 2 2
0 -=03
o ¢MZ
6. LANDS SHOWN HEREON WERE NOT ABSTRACTED BY THIS
�` Va
wmnx
OFFICE FOR RIGHTS -OF -WAY, EASEMENTS OF RECORD,
?
_ Fzwo
OWNERSHIP, ABANDONMENT'S DEED RESTRICTIONS OR MURPHY ACT
WW
Kozo
d w 2 z
DEEDS.
�±
2
a'- oIN*
O OOmo
7. REPRODUCTIONS OF THIS MAP ARE NOT VALID WITHOUT THE
.4InxwZ1
U zawu
~ u
SIGNATURE AND ORIGINAL RAISED SEAL OF A FLORIDA LICENSED
zw W
~3w
SURVEYOR &MAPPER.
W
� (�
�o?�a
~
8. ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS BY
V
o�i-2
Z,ww
OTHER THAN THE SIGNING PARTY OR PARTIES IS PROHIBITED
z ; F z
WITHOUT WRITTEN CONSENT OF THE SIGNING PARTY OR PARTIES.
SCANNNUO.JJBy
°moo
r
St' Lucie
owox
9. INFORMATION SHOWN HEREON IS BASED ON DEED AND FIELD
Cou
"0 °
MEASURED DATA, ALL MEASUREMENTS ARE IN ACCORDANCE WITH
UNITED STATES STANDARD, IN FEET AND DECIMALS THEREOF.
DRAWN BY. CA
10. THE LAST DATE OF FIELD WORK WAS JANUARY 25, 2019.
11. ELEVATIONS SHOWN HEREON ARE IN FEET AND BASED UPON
CHECKED BY, CA
NORTH AMERICAN VERTICAL DATUM (NAVD) OF 1988. BASE
DATE: JUNE 19, 2018
BENCHMARK BEING NGS "C-25-9" WITH AN ELEVATION OF 22.57'
HDRIZONTAL SCALE+
NAVD OF 1988.
1'=30'
12. THE EXPECTED USE OF THE SURVEY AND MAP IS
RESIDENTIAL.
NOT VALID WITHOUT THE SIGNATURE
AND ORIGINAL RAISED SEAL OF A
FLORIDA LICENSED SURVEYOR &
MAPPER.
GLOBAL POSITIONING SYSTEM (GPS) NOTES
1. REAL TIME KINEMATIC (RTK) METHOD WAS UTILIZED USING A TWO
(2) DUAL FREQUENCY TOPCON HYPER GA II SYSTEM. SEAL
2. TYPICALLY, A BASE RECEIVER IS SET UP ON AN ESTABLISHED
CONTROL STATION WHILE A ROVING RECEIVER LOCATES EXISTING
MONUMENTS, IMPROVEMENTS AND CONTROL ON THE PROJECT. CHARLES ARNOLD
PROFESSIONAL SURVEYOR & MAPPER
3. CPS SURVEY MEASUREMENTS WERE PROCESSED AND ADJUSTED FLORIDA LICENSE NO.4971
USING CARLSON SURVEY 2008, - Z7
4. THE HORIZONTAL TARGET ACCURACY FOR THIS SURVEY EXCEEDS PRINTED DAY
MINIMUM STANDARDS OF PRACTICE PER FLORIDA ADMINISTRATIVE CODE SHEET 1 OF 1
(F.A.C.) 5J-17-051.
PROJECT N0. 18-531
go
K
ON
ol 30'60 '1
LEGEND & ABBREVIATIONS
A
ARC LENGTH
A/C
AIR CONDITIONER
BM
BENCHMARK
C
CALCULATED FROM FIELD MEASUREMENTS
C/L
CENTERLINE
CM
CONCRETE MONUMENT
CONIC
CONCRETE
DEG OR
DEGREE
ELEV
ELEVATION
FFE
FINISHED FLOOR ELEVATION
FND
FOUND
ID
IDENTIFICATION NUMBER
IP
IRON PIPE
IR
IRON ROD
IRC
IRON ROD & CAP
LB
LICENSED BUSINESS
LS
LICENSED SURVEYOR
M
MEASURED DATA
MON
MONUMENT
N&C
NAIL AND CAP
NAVD
NORTH AMERICAN VERTICAL DATUM
NGVD
NATIONAL GEODETIC VERTICAL DATUM
NO OR #
NUMBER
NTS
NOT TO SCALE
OHP
OVERHEAD UTILITIES
ORB
OFFICIAL RECORDS BOOK
P
PLAT DATA
PG(S)
PAGE(S)
PLS
PROFESSIONAL LAND SURVEYOR
POB
POINT OF BEGINNING
POC
POINT OF COMMENCEMENT
PRM
PERMANENT REFERENCE MONUMENT
PSM
PROFESSIONAL SURVEYOR AND MAPPER
R
RADIUS
RLS
REGISTERED LAND SURVEYOR
R/W
RIGHT-OF-WAY
®
WATER METER
&
AND
©
AT
A
DELTA
0
UTILITY POLE
SITE PLAN
LOCATED IN SECTION 5, TOWNSHIP 35 SOUTH, RANGE 39 EAST
SAINT LUCIE COUNTY, FLORIDA
FND 4X4 CM
PRM LS 1192
I 31
I NI
O
�I
O
I �I
I
2 2.8
I I I II
I I I II
O to
O
I II
1 LOT 3
1 o OCCUPIED
FFE = 24.9'
I I I II
75.00'
23,7
I I V 23,1 EXISTING
WELL
12
X 3.35' 3.36'
I � o
I
I
i
I
I
I
O N
EXISTING I p I O
SEPTIC I tl C x 3.8 0
x 24• I y
I
x 24.9
22.1 20.6
x 21.7
FND % IRC 122.27 2 ,32
FND RAILROAD SPIKE
NO ID
1 3 .00 I 22 8 S 8902525" E j X 300.00' LS # 4363 30.0 22.2
5' E- ARM FkCEx - x - - x x 3( x FND NAIL S DISK
I
i I
I
SET % IRC 2
9
3
LB # 90a3
4)i°a30.04'
ooI
M1 m
0
35.00'�
0
oYQ�IIII
IIlI
y0N=
'NwQ. o�s im
°
11oVAcoLL23.3
T 4
h7
Cx
� W�
I
C
�30.56'
a �
35.00'
5.09 PROPOSED NO ID (BENCHMARK)
0, N\23DRAINFIELD O
PROPOSED a +-35osa FT PROPOSED I ELEVATION = 22.36'
2 to
WELL O o - GREEN I C I
\ tp zs.o a AREA O. N
O W O
151.62' 25� - - - 25.0c o0 a
0111 34.00' °0 to
O h ufwaft
23.5x
I I _I
1 h o 23,8 23.2 /
39'.00' _
F R
NO ID
I 1
I I 1
I
I I i
� I 1
1
I I 1
22.81
I
I I
I
I
I
/
12.00
p y W
W m V iq
V
00'
PROPOSED 0)
EXISTING
l
N
Q �
COVERED
ENTRY
2.54
HOUSE P o
c
111
21,9
22,5
/
a h � g �
50.8'
x21,
o0
,z.no
!
1141.85' COVERED
34.00'
24.0 20.8
22,48
PURGH
25,0 - - - -
ROPOSED
oT
23•
-
- 3
18'x22�
25,0
CONCRETE
O
NPROPOSED
16'
O
H
SHELL DRIVE
I
2 60
I FND NAIL 8 DISK
300.00'
A✓B YIL>-AIC FMB.
S 8902525" E
-® 22.9
EXISTING
WELL
LOT
OCCUPIED
FFE = 25.5'
FND %IR 2.81*-
NO ID
22.0/ ' \21.8
x 24.8 I 21,5
I
3
24.6
I
O
_
O
N
x 24.1
c
O
,
25,5
"
c
x 23.8 I
y
24.3 EXISTING
SEPTIC I
y NO ID (BENCHMARK)
/ ELEVATION = 22.82'
J2,8
I
FND RAILROAD SPIKE
NO ID (BENCHMARK)
ELEVATION = 22.97'
FILE COPY
LOCATION MAP
NOT TO SCALE
STREET ADDRESS
UNASSIGNED CODY LANE, FT. PIERCE, FL. 34945
LEGAL DESCRIPTION
LOT 4, BLOCK B, COUNTRY LIVING ESTATES, UNIT 1, AS PER
THE PLAT THEREOF, RECORDED IN PLAT BOOK 18, PAGES 13
OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA.
. N N 0
V uj M
-aw �N�
m ° A Coll
a
zN=z uo�
�a�
�oW LL
Lu W
` W Z at call
J O�
LL
F N
NNW 0
J Z QN¢
W x
Z 0 2 > a�
JOn =o
0,N
0 tiZ a
ZwR 2N
� L- 0 z Ul
QD LL °° O
a 00
co _
a
z
0
z >
LU
J O-'
w
z
w
Q A
L.I w
a
Q r
U U pq
(IN 00
GENERAL NOTES
(\LI (U W�
1. THE BEARINGS SHOWN HEREON ARE BASED UPON THE A
CENTERLINE OF CODY LANE, AS RECORDED IN PLAT BOOK 18, C
PAGE 13, PUBLIC RECORDS, ST. LUCIE COUNTY, FLORIDA, HAVING
A BEARING OF SOO`40'20"E.
2. FLOOD NOTE: BY GRAPHIC PLOTTING ONLY, THIS PROPERTY
IS IN ZONE "X", ACCORDING TO THE FLOOD INSURANCE RATE MAP, a�Z3
COMMUNITY PANEL NO. 12111 C 0155 J, EFFECTIVE DATE <-
FEBRUARY 16, 2012. THE EXACT DESIGNATION CAN ONLY BE 6
DETERMINED BY AN ELEVATION CERTIFICATE. Z
w o
w o >woo
3. ALL ABOVE GROUND FIXED IMPROVEMENTS, IF ANY, HAVE Z N W'��
�o
BEEN LOCATED AND SHOWN HEREON. 0 zoo:o
co=ww
4. THE SURVEYOR HAS NO KNOWLEDGE OF UNDERGROUND Z W V c-�<om
FOUNDATIONS WHICH MAY OCCUPY LANDS OF OTHERS. O IlaW Z UZN
w 0� �w
Zoww
5. UNDERGROUND UTILITIES AND UTILITY SERVICES HAVE NOT Q m y = -Zao
o Qpo=Fa
BEEN LOCATED ON THIS SURVEY, EXCEPT AS SHOWN. V 2 Z
o ow8
u- ` O ¢ =w-OU
6. LANDS SHOWN HEREON WERE NOT ABSTRACTED BY THIS 1_ F
OFFICE FOR RIGHTS -OF -WAY, EASEMENTS OF RECORD, j = wWF-g
OWNERSHIP, ABANDONMENT'S DEED RESTRICTIONS OR MURPHY ACT Lll �j W } od�o
DEEDS. (i Z -W
d " o
CU <Z'�3
7. REPRODUCTIONS OF THIS MAP ARE NOT VALID WITHOUT THE ll1 j 5>00
SIGNATURE AND ORIGINAL RAISED SEAL OF A FLORIDA LICENSED w-,F-w
Dww�
SURVEYOR &MAPPER. OoO
u% o m
8. ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS BY w `w=
OTHER THAN THE SIGNING PARTY OR PARTIES IS PROHIBITED V zooa
WITHOUT WRITTEN CONSENT OF THE SIGNING PARTY OR PARTIES.
oa
9. INFORMATION SHOWN HEREON IS BASED ON DEED AND FIELD N <aoow
MEASURED DATA, ALL MEASUREMENTS ARE IN ACCORDANCE WITH
UNITED STATES STANDARD, IN FEET AND DECIMALS THEREOF.
10. THE LAST DATE OF FIELD WORK WAS JUNE 18, 2018. DRAWN BY. CA
11. ELEVATIONS SHOWN HEREON ARE IN FEET AND BASED UPON CHECKED BY: CA
NORTH AMERICAN VERTICAL DATUM (NAVD) OF 1988. BASE DATE: JUNE 19, 2018
BENCHMARK BEING NGS "C-25-9" WITH AN ELEVATION OF 22.57'
NAVD OF 1988. HORIZONTAL SCALE:
1'=30'
12. THE EXPECTED USE OF THE SURVEY AND MAP IS
RESIDENTIAL.
NOT VALID WITHOUT THE SIGNATURE
AND ORIGINAL RAISED SEAL OF A
FLORIDA LICENSED SURVEYOR &
MAPPER.
GLOBAL POSITIONING SYSTEM (GPS) NOTES
1. REAL TIME KINEMATIC (RTK) METHOD WAS UTILIZED US] A TWO
(2) DUAL FREQUENCY TOPCON HYPER GA II SYSTEM. m SEAL ! t
m Z n
2. TYPICALLY, A BASE RECEIVER IS SET UP ON AN ESTABL � Et6 G ,�
CONTROL STATION WHILE A ROVING RECEIVER LOCATES EXISTIN � fl Z-1i
MONUMENTS, IMPROVEMENTS AND CONTROL ON THE PROJECT. 78ARLES ARNOLD
3. GPS SURVEY MEASUREMENTS WERE PROCESSED AND ADJU D PROFESSIONAL SURVEYOR & MAPPERFLORIDA LICENSE NO. 4971
USING CARLSON SURVEY 2008.
4. THE HORIZONTAL TARGET ACCURACY FOR THIS SURVEY EXCEEDS PRINTED DA E
MINIMQlM STANDARDS OF PRACTICE PER FLORIDA ADMINISTRATIVE CODE SHEET 1 OF 1
(F.A.C.) 5J-17-051.
PROJECT N0. 18-531
1
1
Floor Plan
scale: 1/4" = 1'-0"
wvio
Connector Schedule
Truss
Bearing
Truss
Connector
Qnty
Connector
Fasteners
Point
Uplift
ID
Uplift
All trusses
Each
<1810
HETA20
1
1810#
(9) 1 Od x 1 1/2"
<1810
HETA20
1
1810#
(9) 1 Od x 1 1/2"
to CBS
Brng.
All trusses
Each
<1000
MTS18
1
1000#
(9) 10d x 1 1/2"
<1000
MTS18
1
1000#
(9) 10d x 1 1/2"
to Frame
Brag
Valley
Supporting
Framing
(4) 1Od
Trusses
<250#
VTCR
1
370#
Valley
Truss
(3) lOd x 1 1/2"
Connector Notes:
Do not substitute connectors
Do not sheath trusses before all straps are in place
Attach valley trusses and piggy back trusses, if present,
to main trusses per truss manufacturer drawing.
Truss to truss connection by truss company, installed.
per manufacturers specs.
Lateral forces perpendicular and parallel to wall has been
considered (less than 300 p.l.f.)
Contractor to approve temporary bracing to prevent toppling
of trusses, see HIB-9.
Other specs, if different from above, have priority.
A.T.R. = All Treaded Rod
Drill and Epoxy Set all A.T.R.
Use either "Hilti" C-100 or Simpson Epoxy Tie Epoxy
Provide equal number of studs under girders equal to
the number of plys.
Project Data
Project Name: Beebe Residence
Street Address: XXXX Cody Lane
City: Ft. Pierce
County: St. Lucie
State: Florida
Scope of Work
New One level CBS
Single Family residence
Design Loads
Roof Live Load: 30.0 p.s.f.
Wind Speed: 160 MPH
Wind Importance Factor: 1.0
Building Category: II
WindFxposure: C
Internal Pressure Coefficent:.18
Structure Designed: Enclosed
Soil bearing capacity: 2000 p.s.f.
FILE COPY
Building Data
Occupancy Type: Group R
Construction Type: V
Number of Stories: One
Project Area: 2336 s.f.
Building Code
2017 Florida Building Code: Residential
2014 National Electrical Code: NFPA 70
Area Tabulation
Living:
1768
Porch:
408
Entry:
160
Total: 2336
Total Cubic Volume: 20060 c.f.
Climatic & Geographic Design Criteria
Weathering: Negligible Termite Area: Very Heavy
Flame Spread Index & Smoke Developed Index
Insulation Flame Spread: Not to exceed 25
Insulation Smoke Developed Index: Not to exceed 450
Wall Finishes: Not greater than 200
Ceiling Finishes: Not greater than 200
Spra, Foam
Insulation
)'4„FW
1/2" d.w
1 x 4 p.t.
Firestop
One Course Perimeter
Beam with (1) #5 Rebar
Filled with Grout
1 x 2 p.t. furring
strips 24"o.c.
with R4.1 Foil
insulation
1/2" d.
#5 vert, rebar in
grout filled cell
See Floor Plan
for Locations
4" 3000# Fibertrix Conc.
on .006 Vapor Bearier on
Clean, Compacted, Termite
Treated Fill
0.00' F.F.E.
(2) #5
Rebar P-6"
5V Metal Roofing
over 30# Felt on
19/32" c.d.x. plywood fastened
as per nailing schedule
Pre Engineered Wood
Roof Trusses 24"o.c.
Shop Drawings by
/ Others
See Connector
Schedule
/ 12 2 x 4 p..t. - 2 x 4 24"o.c.
Q 6` Cont.
Alum. Drip Edge
2 x 6 Fascia
Alum. Wrap
Stucco Soffit Over
High Ribbed Wire
2'-O'p Lath
Install one layer of 15#
felt to framing prior to
installing wire lath
8x16x8
CMU Typ.
Light Textured
Stucco Finish
#5 Vert. Rebar with
10" Hook and 30"
Lap. Tie to Vert.
Rebar In Cells
,o I Grade
O
ti
0
w
U
Q
w
CW7
t!1
0
w
0
a�
U
W
V)
date revision
SCANNED
Ry
St Lucie County
drawn
s.l.
checked
s.l.
date
12/1h 18
scale
as noted
job number
18057
deal Wall Section sheet
1
0
to w
Cl
ow
J
Y.C9w w3
n?z u nV)
1 �a ui
� JOz
ma
6
U
�z G
N
00
02> a?
u
~
uww aZ
Jwww2o
LU
F-wwCg�
z W o
a
W
N W U
LL
s✓ O Z
Z
V
cc
C 3
r
/W
I I
ct
'
Y~¢
00 o
WW U¢ V
~
V1
p
s w W
aoa�o,.�
.�
Ri
(D
¢
a
na g
o
�I Q
a3
V 1
N s01 l
w���
Z
C�
r
U
>
W
a
Hto
> d- • (J
���-II
c
fL
`c
ctt
OQ
i U
Q
M
V
RECEIVED
DEC 2 6 2018
OT; Lucie Cglanty. perailttln#
Ll
+33.5 +33.5 +33s
-36.3 6.3 44.s -3
Right Elevation
scale: 1/4" = V-0"
PRODUCT APPROVAL
Approval
Product
Model Number
Manufacturer
Glass
Attachment Method
Building Rated
Product Rated
Number
Ty
Design Pressures
Design Pressures
Head: 12` max. from corners & 30"o.c. max. Iambs:
SH-5500
5/16"
12" max. from corners & 17.7" max. 5" each side of
NOA: 15-0519.05
Windows
Singlehung
PGp Industries
Lam.
meeting rail. Use 3/16" Tapeon with 1 1/4" embedment
+33.5 -44.9
+/- 50.0
into concrete
FL#: 17184.5
Fiberglass
g
5/16"
6" from cornets 8: 14"o.c. at jambs. 1/4" tapeon
FL#: 17194.3
Swing Doors
Door
Plastpro
Lam.
screws with 1 1/4" embed into cone.
+33.5 -36.3
+/- 50.0
FL#: 17184.1
Approval
Product
Model Number
Manufacturer
Attachment Method
Building Rated
Product Rated
Number
Design Pressures
Design Pressures
FL#: 7271.3
Roofing
5 V Crimp (26 ga.)
Union Corrugating
Rib 12"o.c. or #10-14 x 2" Long wood screw with washer at each
Rib
-65.2
-113.1
FL#: 13192.2
Siding
Hardie Plank
James Hardie
Fasteners shall be ET&F block nail .30 Head dia..14 Shank dia. and
1 1/4" long. 21"o.c. max. spacing
-50.0
-92.0
(Optional)
Roofing
Underlayment
Titanium PSU
IrterWrap
hoofing
One layer direct to plywood with 4" Honz. Laps and 6" Vertical Laps
-NOA#:14-06D3.19
Roof Plan
scale: 1/8" = 1'-0"
Il'-0" Setback
FIN
Nu LE
Front Elevation
scale: 1/4" = l'-0"
+33.5
-36.3
5'-0" Setback
+33.5
-36.3
+33.5 +33.5
-36.3 -36.3
9' 4„ T.O.B.
G
0,00' F�- P'E
Left Elevation
scale: 1/4" = l'-0"
LEJ
+33.5
-36.3
-36.3
+33.
36.33
+33.5
-36.3
U+33.5
Rear Elevation
scale: 1/4" = 1'-0"
U
CT
to
w
Qx
w
�
z
c7
a
bA
�
Q
S..i
Gl
L
Ln
O
�
O
Ct
F-
U
H
V)
•
x
O
,�
r
Con
00
M
O
w
w
a�
U
W
(U
o
Q
It
x
�
�
�
o
~;
Q
-U
w
s.4
.�
w
�
�
z
drawn
s.l.
checked
SAL
date
12/16/18
scale
as noted
job number
18057
sheet A /�
2
F-1
F-2
F-3
18" x 16" mono. footing
with (2) #5 rebar cont.
18" x 16" mono, footing
with (2) #5 rebar cont.
8" x 8" mono. footing
with (1) #5 rebar cont.
4"
4„ 4"
4"
4++ Ott
411 Ott
16"
12' gtt
18 it
8'
1 g
MONO. EDGE FOOTING
FOOTING
STEP 00
THICKENED EDGE
Foundation & Footing Plan
PLUMBING NOTES:
Plumber to consult with contractor and equipment ordered
for rough in dimensions.
Verify all dimensions with the floor plan. The floor plan
dimensions dictates all other dimensions on other sheets.
Do not scale drawings, if any conflicts arise, contact the
Architect or Engineer for clarification prior to construction.
All sanitary lines 2" or less shall have a slope of 1/4" per
foot minimum.
All sanitary lines above 2" shall have a slope of 1/8" per
foot minimum.
Provide Anti -Scalding Valve in all showers
Lowest living area floor elevation (refered as 0.00') to be
set by a professional land surveyor to the required building
department elevation, but not less than 18" above the crown
of the road.
2" v.ir. 1, , I r
sanitary
tstem
Insulate all hot water litres
robing Riser Diagram
Cast Crete Lintel Schedule
All Rebar to be #5 Grade 60 min.
MARK
LENGTH OF
LINTEL
ALLOWABLE
GRAVITY LOAD
APPLIED
GRAVITY LOAD
ALLOWABLE
UPLIFT LOAD
APPLIED
UPLIFT LOAD
BEAM SPECS,
L-1
3'-S"
6113
257
3079
83
SF16 1B/lT
L-2
T-8"
1568
784
931
259
8RF14113/1T
L-3
4'-6"
6113
1553
2724
670
8F16113/1T
L-4
8'-0"
1843
667
1133
247
SF16113/1T
L-5
18'-8"
750
257
347
83
8F16113/1T
L-6
12'-0"
1254
601
723
218
8F161B/lT
L-7
10'-10"
1366
257
798
83
8F16 113/1T
Min. Beam depths shown, beams may be increased without convent
At Lintels 24" deep or larger, provide (1) #4 vertical rebar tied to
Horiz. steel at 24"o.c. along length of lintel
Safe Load Table Notes
1. All values based on minimum 4" nominal bearing.
Exception: Safe loads for unfilled U lintels must
be reduced by 20% if bearing length is less than
6 1/2".
2. N.R. = Not Rated
3. Safe loads are superimposed allowable loads.
4. One #7 rebar may be substituted for two #5
rebar in 8 inch U lintels only.
5. All safe loads in units of pounds per linier foot.
6. All safe loads are based on simply supported span.
7. Safe load ratings based on rational design analysis
per ACI 318 and ACI 530.
N5 mbar et
U)R4a.
gvan�y "rrs mbar
uw om mr�ml
Hai%roue
cavdy
z wmro
�I III"F-
z
-
8F16-1B/IT
5/8r #5 rebar at bosom
oflmtd'.Y'
oonJnol—r
helgth
V`vaniryofolJ
.bar at top
Lintel Type Designation
Installation Notes
1. Installation of U lintels must comply with architectural
and/or structural drawings.
2. U lintels can be field cut to the required length.
3. Cast in place concrete may be provided in composite
U lintel in lieu of concrete masonry units.
4. The exterior surface of U lintels installed in exterior
concrete masonry walls shall have a coating of stucco
applied in accordance with ASTM C-926 or other
approved coating.
5. Concrete masonry units used in composite U lintel shall
be laid in a running bond.
6. Shore composite lintels as required.
7. U Lintels are manufactured with a 5 1/2" long notch at
both ends to accomodate vertical cell reinforcing and
grout.
Composite U Lintel Materials
1. Grout per ASTM C476 fg-3000 psi with maximum 3/8
inch aggregate and 8 to 11 inch slump.
2. Rebar per ASTM A615 Grade 60
3. Concrete masonry units (CMU) per ASTM C90 with
minimum net area compressive strength = 1900 psi
4. Mortar per ASTM C270 Type M or S
U
I —I
�
M
Ow
N
to
•�
>
U
O
rrC��
W
V
o
W
cU
C7
>
o
C�
r---I
>
U
E-
Ln
d
L
rl
00
00
M
F�
r�
Cast in place sill or Tie Beam Option
In the event that precast products are damaged in the
field cast in place sills and tie beams may be used (not
to exceed 5'-10") Typical cast in place tie beam to be
a min. 8" x 12" with (2) #5 top and (2) #5 bottom
O
w
cu
v
z
�
b
.3
W
Q
(U
�
o
w
sa
Q
�i
U
z
FORMWORK & SHORING GENERAL FOUNDATION NOTES
No structural concrete shall be stripped until it has reached at least 80% of Concrete shall be a minimum of 4" thick over clean, compacted,
the 28 day design strength,
termite treated fill and 6 mil polyethylene vapor barrier.
Design, Erection, & Removal of all formwork, shores, & reshores shall meet If concrete slab contains 6" x 6" 10/10 V VM provide 1" coverage
meet the ACI Standards 347 and 301
Contractor to verify all building setbacks prior to the start of construction.
A formboard survey shall be submitted to the building department for
approval prior to pouring concrete.
SOIL STATEMENT:
Foundation has been designed for a soil bearing capacity of 2000 p.s.i.
Fill shall be laid in layers of 6". Each layer to be compacted to 95%
compaction.
If the contractor encounters, while digging the foundation, any
discreppa�ncyy to suggest the soil may be madecuate, he must
immediately report it to the owner and the Architect or Engineer
so as to order a soil boring test.
Dowel Rod Repair Note
In the event vertical steel has been omitted from the down
pour locations, drill 5" into concrete (no closer than 3 3/4"
from edges and 5" from ends of cap walls) Remove dust
per manufacturers instructions and use Two Mart epoxy to
anchor the #5 rebar in place. Use either "Hilts C-100" or
Simpson Epoxy -Tie.
Concrete shall have at minimum compressive strength of not less
than 3,000 p.s.i.
All 90% hooks are to be extended 10" minimum beyond the turn.
Field bends are to be done cold and the diameter of the bend,
measured on the inside of the bar, is not to be less than six
bar diameters.
Minimum coverage for rebar shall be 3" in footin$.s and 1 1/2" in
bond beams. Hooks may be rotated horizonitally if required to
achieve minimum coverages.
Rebar overlap shall be 48 bar diameters. 30" for #5 rebar
The foundation design assumes that the soil has a minimum
load carrying capacity of 2000 p.s.f.
In the event the soil bearing capacity falls below 2000 p.s.f. This
foundation plan may be superceded by Foundation Design Engineer.
Satisfactory compaction test of fill does not verify lower soils are
adequate.
All specifications and dimensions to be verified by contractor.
All exterior slabs shall slope a minimum 1/8" per foot for drainage
drawn
0.
checked
sd.
date
12/16/18
scale
as noted
job number
18057
sheet
A-3
STRUCTURAL NOTES:
All reinforcing steel shall be high strength billet steel and shall
conform to ASTM A-615 grade 60 specifications. Lap continuous
reinforcing 48 bar diameters or 30" in beams and in slabs. Lap
bottom steel over supports and top steel at midspan. Hook
discontinuous ends of all top bars. Reinforcing steel shall have
a minimum of 1" concrete cover, or as follows:
BOTTOM TOP SIDES
Beams: 11/2" 11/2" 11/2"
Slab on Grade: 1 1/2" Y, _
Structural Poured: 3/4" 3/4" _
Poured Walls: _ _ 3/4'
Slabs exposed
to the weather 3/4" 1" _
Reinforcing steel shall be detailed and fabricated in accordance
with the "Manual of Standard Practice of Detailing Reinforcin$
Concrete Structures" and the current "ACI Building Code 318
All structural steel shall conform to current ASTM Specification A-36
All wood in contact with masonry shall be pressure treated or approved
seperating material.
All dimensions shall be verified in field by the contractor. If
there are
any discrepancies the Architect or Engineer shall be notified before
proceeding.
No slump over 5" shall be permitted for any structural concrete without
the Architect or Engineer approval.
All Design and Construction shall be inaccordance with the current
American Concrete Institute (ACI). and the American Institute of Steel
Construction (AISC), The Florida Building Code and all applicable
local codes.
Structural Concrete shall attain a minimum ultimate compressive strength
(Fc') in 28 days as follows:
Column Footing and Wall Footing: 3000 p.s.i.
Column and walls from foundation to roof: see column schedule.
All other concrete: 3000 p.s.i.
Footing sizes and reinforcing are based on allowable soil bearing
capacity of 2000 p.s.i. All footings shall bear in virgin soil. If this
is not the case, the Architect or Engineer shall be notified before
proceeding with the work.
Timber (Heavy Timber Construction)
(a) Truss manufacturer shall submit a signed and sealed shop
drawings by a registered Engineer.
(b) Wood rafters to have a Stress Grade ofFb=1200 p.s.i.
(c) Roof members should be secured to the beams or other
structural components with hurricane anchors for wind uplift.
All wood members shall have a minimum fiber stress in bending
of 1200 p.s.i. with 1/360 max. deflection.
All bolted connections shall be 1/2" Cadmium plated or better,
Lag bolts to be used only in shear connections with minimum
4" threaded penetration past steel plate.
Lag bolted conditions shall be drill tapped no larger than the
internal thread diameter and shall not be hammer driven.
Under Girder Trusses provide equal number of studs as girder
plys at frame bearing locations
GENERAL REQUIREMENTS
All work to be as per the current edition of the Florida Building Code
and meet or exceed all applicable local requirements.
General contractor is responsible for all labor, materials, utilities, testing,
waste removal, storage, securing of site, accomodation, transport/freight,
and all other cost related to the completion of this project., unless explicitly
identified here.
Owner is responsible for all municipal related charges such as impact
fees, and water connection, except building permit fees, which are to be
included in the construction bid.
General contractor to check all drawings for errors and ommissions and
bring them to the attention of the architect prior to starting any work, or
ordering any materials of the respective division of work. If such errors
and ommissions are not reported in writingto the architect, any resulting
damages or costs shall be born entirely by the general contractor.
Architect is not responsible for the contractors method or means of
construction.
General contractor is to keep the site in a clean and safe state through
out the course of construction. On building turnover, general contractor to
clean all surfaces so as to be free of dust, grease, stains, scuffs, etc.
Unless otherwise noted, the installation of specified hardware shall
conform to the manufacturers instructions and standard practice.
All plans and drawings are not considered complete until they have been
reviewed and approved by the St. Lucie County Building Department
and the building permit has been issued.
EXTERIOR CEILING & SOFFIT NOTE
7/8" Stucco finish over 3/8" high ribbed galv. wire lath fastened to
framing members with No. 11 guage nails with 1 3/4" embed. with 3/8"
dia. head 6"o.e. max. edges to be tied and nailed at 9"o.c.
Install one layer of 15# felt to framing prior to installing ribbed lath
INTERIOR WALL FRAMING NOTE
Interior non bearingg walls to be 2 x 4 studs 24"o.c.
Spruce, Pine, Fir (SPF) #2 Grade lumber or better
or metal studs (25 Ga.) Crimper may be used in
lieu of screws.
GENERAL ROOFING NOTES
Roofing to be composed of and attached to pre manufactured
wood trusses as follows
Felt underlayment (min. ASTM 0 226 Type 11) with 4" min, side and
end laps, fasten with coorosion resistant annular ring shank nails
at 6"o.c. in laps and in staggered rows spaced 12"o.c. in field,
If roof pitch is < 4/12 install (2) layers 15# felt.
If roof pitch is 4/12 or greater, install (1) layer 30# felt.
5/8" cAx. sheathing or equal installed with staggeredjoints & GI clips,
nailed to trusses with 8d corrosion resistant annular ring shank nails
spaced max. 6"o.c. throughout, except max. 4"o.c. at gable ends.
All roof trusses are to be pre -manufactured assemblies provided by
a licensed wood truss fabricator with seperate drawings and data
prepared for actual project conditions by a Florida registered
professional engineer certified for truss design. Any deviation from
the proposed plans as shown regarding placement or bearing shall
be brought to the attention of the truss engineer prior to fabrication
of the trusses. The truss manufacturers cemfied layout shall govern
after fabrication.
The handling, erection, and fixing of wood trusses shall be in
accordance with the specifications contained on the certified mfgr's
drawings and data.
All engineered headers and truss hangers to be provided by the
truss manufacturer.
structural components
Splitting or cracking of due to installation of
hardware is not permitted.
Unless otherwise noted, the installation of specified hardware shall
conform to the truss manufacturers installation instructions and
standard practice.
i
BUCK ATTACHMENT NOTES
AT DOORS USE P.T. PINE OR SPRUCE AND ATTACH
TO BLOCK WITH 1/4" DIA. TAPCONS INTO. C.B.S.
SET AT 6" FROM CORNERS AND AT 12"o.c. MAX.
AT WINDOWS USE P.T. PINE OR SPRUCE AND ATTACH
BUCKS TO BLOCK WITH 8d CASED HARD COIL NAILS
OR "T" NAILS" 4" FROM ENDS AND 12"o.c.
USE WOOD SHIMS MINIMUM DURING DOOR INSTALLATION
SHEATHING NAILING NOTES
Nailing Pattern
Zone 1: 8d at 6b.c. field & 4"o.c. edges
Zone 2: 8d at 4"o.c. edges & field
Zone 3: 8d at 4"o.c. edges & field
Pneumatic Nails
Pneumatic or mechanicaly driven nails will
be accepted under the following conditions:
Min. nails size 8d or larger ring shank with
Min. shank diameter:.113
Min. Length: 2"
Min. Head Diameter:.280 Full Round
Min. Ring Diameter .012 over shank dia.
Min. 16 to 20 Rings per Inch
Note
Gun nails shall be permitted as an
acceptable fastener from any manufacturer
Wood screws meeting the same size requirement
may be used in lieu of nails without comment
Nailing Schedule
ROOF & FLOOR DIAGRAM
Use sheathing with #8 gun nails at 6"o.c.
at supported panel edges and #8 gun
nails at 6'o.c. at intermediate supports.
ROOF SHEATHING TO GABLE END FRAME
Use #8 gun nails at 4"o.c.
EXTERIOR SHEATHING
Use #8 gun nails at 4"o.c. at panel edges
and #8 gun nails at 4"o.c. at panel top and
bottom and 6"o.c. in field
THRESHOLD NOTE
At egress door (see floor plan) the max. hgth.
of the threshold shatl be 1/2"
Wire Lath Attachment
Over wood framing the paper
backed wire lath shall be installed
over one layer of approved plastic
house wrap. Lath shall be attached
horizontal framing members with 1.5"
roofing nails and to vertical wood
framing members with 6d common
nails or 1" roofing nails driven to
penetration of not less then 3/4"
of an inch, or 1" wire staples
driven flush with the plaster base.
Staples shall have crowns not less
than 3/4" and shall engage not less
than three strands of lath and
penetrate the wood framing members
not less than 3/4". The fasteners must
penetrate the wood framing members
not less than 3/4". Fasteners shall be
7" o.c. max.
Ceramic Tile
Shall be installed in accordance with ANSI At08.1, A108.4, A108.5
A108.6, A108.11, A118.1, A118.3, A136.1, & A137.I. Fiber mat reinforced
backer shall be used behind wall applied ceramic tiles in the tub
and shower areas and conform to ASTM C 1325. Per Durock,
cement board exceeds ASTM C1325.
GVDSUm Note
Gypsum board shall conform to ASTM C22, C475, C514, C1002, C1047
C1177, C1178, C1278, C1396, or C1658 and installed per FBC residential
code. Per USG, Wallboard conforms to C1396.
Gvnsum Board & Gvnsum Panel Products
Gypsum board and gypsum panel products shall be applied
at right angles or parallel to framing members. All edges and
ends of gypsum board and gypsum panel products shall
occur on framing members, except those edges and ends that
are perpendicular to the framing members. Interior gypsum
board shall not be installed where it is directly exposed to
weather or to water.
Wall and ceiling gypsum board shall be fastened with screws
spaced at 12"o,c. Screws for attaching gypsum board and gypsum
panel products to wood framing shall be Type W or Type S m
accordance with ASTM C1002 andshall penetrate thewood not
less than 5/8" inch (15.9mm) Gypsum board and Gypsum panel
products shall be attached to cold formed steel framing less
than 0.033" (lmm) thick shall be Type S in accordance with
ASTM C1002 or bugle head style in accordance with ASTM C1513
and shall penetrate the steel not less than 3/8" to 0.112"
(lmm to 3mm) thick shall be in accordance with ASTM C954 or
bugle head style in accordance with ASTM 1513. Screws for
attaching gypsum board or gypsum panel products to structural
insulated panles shall penetrate the wood structural panle facing
not less than 7/16"o.c. (11.lmm).
Gypsum board used as the base orbacker for adhesive application
of ceramic tile or other required nonabsorbent finish material shall
conform to ASTM C1396, C1179, C1278. Use of water resistant
gypsum backing board shall be permitted on ceilings. Water
resistant gypsum board shall not be installed over a Class 1 or
Class 2 vapor retarder in a shower or tub compartment. Cut or
exposed edges, including those at wall intersections, shall be
sealed as recommended by the manufaetuer. Water resistant
gypsum backing board shall not be used where there will be
direct exposure to water, or areas subject to continuous high
humidity,
Cold Formed Steel Note
Cold formed steel framing supporting gypsum board and gypsum
anel products shall be not less than 1 1/4" (32mm) wide in the
least dimension. Non Load bearing cold formed steel framing
i shall comply with AISI S220 and ASTM C645, Section 10. Load
bearing cold formed steel framing shall comply with AISI S200
and ASTM C955, Section 8.
L
Wood Framine Note
Wood framing supporting gypsum board and gypsum panel
products shall be not less than 2" (51mm) nominal thickness
in th least dimension except that wood furring strips not less
than 1" by 2" (25mm x 51mm) nominal dimension shall be
Permitted to be used over solid backing or framing spaced
not more than 24"o.c. (610mm)
Roof Wind Zones
2 x 4 blocking at 4'-0"o.c.
starting from ridge between
both top and bottom cords
for two truss spaces from
gable end
See truss shop
drawings
2 x 4 diagonal "X"
bracing at 8'4'o.c.
starting from ridge
with (3) 12d each
end -\
(2) 12d trusses 24"o.c.
see layout
Continuous 2 x 4 Lateral
bracing at 1/3 points of
span. Nail with (2) 16d
each truss btm. cord
Continuous 2 x 4 bracing
fastened to beam with
5/8" x 6" wedge bolts
with 1/8" x 2" washer 24"o.c.
Gable End Bracing Detail
1 x 4 bottom cord bracing
101-011
Bottom Cord Lateral Bracing
Wind Zones - Walls
Galv. drip edge
nun. 4" lap
I x 3 p.t. over 2 x 6
Paint Grade Fascia
Gable end truss
by truss mfgr.
19/32" c.d.x. plywood
with 8d nails 4"o.c.
Cover with House Wrap
2x "L" web stiffener
as required by the
truss mfgr.
"Simpson" HETA16 truss
to bond beam with (14)
10d x 1 1/2"
located at each truss
vertical
Concrete Bond
Beam
3/8" continuous bead of
caulk (back bedding) behind
buck to prevent liquid passage
set flange in continuous
bead of caulk across the
entire face of buck
CBS
q Min. 1 1/4" embedment
a at windows and min.
1 1/2" embedment at
G o ° ° A gl. doors
o e
° °
\ (1/2" drywall
I /
stucco finish
perimeter caulk J
Attach F .t .bucks
with 8d coil nails at
12"o.c.
Typ. Alum. window
jamb or sliding glass
doorjamb
NOTE: Method of attachment and
waterproofing procedures are the
same at poured concrete sill.
Wind
Includes
Attachment Method
Alum. window
frame
3/8" continuous bead of
caulk (back bedding) behind
shim to prevent liquid passage
1/4" struct. shim
set flangge in continuous
bead ofcaulk across the
entire face of buck
perimeter caulk
stucco finish
1/4" max. struct. shim
caulk
attach as per
manufacturers
product approvals
Gunable sealants shall comply with
ASTM C 920 Class 25 grade or
greater for properjoint expansion
and contraction
Detail at CBS Wall
corrosive resistant
Tapeon concrete
srews installed as
specified in window
manufacturers product
approval
r-window sill
Gunable sealants shall compply with
ASTM C 920 Class 25 grade or ° ° ° . v
greater for proper joint expansion
and contraction
precast
cone. sill
Typical Precast Conc. Sill Detail
c
O
b
corner bars at beam
(outside only) (2) corner
bars at footing (min.) —
vert. dowel lapped with
wall reinforcing, all
laps 25" (min.) in grout
filled cell
all corner bars to be the
same size, number, and
spacing as horizontial bars
in footing, beams, and walls
Corner Reinforcing Detail
H
ao
M
�
w
W
v
z
b.Q
to
con
.�]
9
U
�
L�
"
A
W
Q�
�
O
J,
Q
W
4)
U
'C
(U
W
O
Q
O
W
z
drawn
S.I.
checked
s.l.
date
12/16/18
scale
as noted
job number
18057
sheet
A-4
b
20
MO
3
ELECTRICAL LEDGEND
RECESSED LIGHT WITH LENS Q EXTERIOR & WET LOCATIONS
SURFACE MOUNTED LIGHT FIXTURE
SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE
UNDER CABINET FLUORESCENT FIXTURE
RECESSED INCANDESCENT LIGHT FIXTURE WITH EXHAUST FAN
C,EU >NG FAN
EXHAUST FAN OUTLET
THERMOSTAT
DUPLEX OUTLET -SWITCHED
DUPLEX OUTLET
220 V OUTLET
SWITCH
THREE WAY SWITCH
® DOOR CHIMES
®SMOKE
& CARBON
MONOXIDE DETECTOR
-+1
TELEVISION
TELEPHONE
g.
PUSH BUTTON
-yr DDAMER SWITCH
NOTE: RECEPTACLES IN KITCHEN & BATH AREAS TO BE 46" A.F.F.
ALL 120V SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS SUPPLYING
OUTLETS THAT ARE NOT GFCI MUST BE "Cl.
TAMPER PROOF RECEPTICALES MUST BE INSTALLED IN 120 VOLT, SINGLE
PHASE 15 & 20 AMP BRANCH CIRCUITS
Elecu7cal Load Calculations
1768 Living S.F. at 3 VA
5304 watts
Two 20 Amp Appliance Ckts.
3000 watts
One Laundry Cir. @ 1500 watts
1500 watts
One lunge
8000 watts
One Dishwasher & One Disposal @
1500 watts each 3000 watts
One Microwave @ 2000 watts
2000 watts
One Water Heater @ 4.5 kw
4500 watts
One Dryer @ 5 kw
5000 watts
One Ref. @ 1500 watts
1500 watts
Two Baths @ 1500 watts each
3000 watts
Total 36,804 watts
First 10 KVA at 100% 10,000 watts
Remainder at 40% 10,722 watts
Total 20,722 watts
One AC Heat at 100% 10,000 watts
Total 30,722 watts
30,722 W / 240 V = 128.0 Amps
Use 200A Service
Smoke detectors wired to 120V Bathroom lights
Non Switchable, Non GFI
Electrical contractor to verify all equipment loads prior to
start of construction. Electrical contractor to recalculate
electrical schedule if loads are to be modified
(3) #2/0 (THW) copper
and (1) #4 around (THW)
copper in 2' galy. conduit
Panel: 200 A.M.C.B. 200 Amp
1,o, 3W 40 Circuit Panel
120/240 Volt
a.c
disc.
5/8" dia. x 10'-0"
long ground rod 3/4" copper
water pipe
8'-9 19/32"
(3) #2/0 (THW) copper
and (1) #4 ground (THW)
copper in 2" galy. conduit
Wall F.P.L. service
[may (if overhead
y service)
(3) #2/0 (THW) copper
and (1) #4 ground (THW)
copper in 2" galy. conduit
F.P.L. service
(if underground
service)
tie ground wire
to footing rebars
Electrical Riser Dia rg am
U
Q
w
U
z
r�
a�
Ln
00
h-1
/>
Q
W
O
w
�
Q
C/1
A ,
rrQ
A�
kV
O
M
�,
t�
Q�
E-
U
In
x
O
N
0C
r---i
CC
r
M
w
w
a�
U
•3
z
�
•�,
w
�
o
w
Cn
w
O
U
W
�
rr1
C7
z
r/1
drawn
s.l.
checked
s.l.
date
12/16/18
scale
as noted
job number
18057
sheet
A— r