HomeMy WebLinkAboutBUILDING SITE PLAN■ AS ANCHOR BOLT MATL MATERIAL AFF ABOVE FINISHED FLOOR MAX MAXIMUM ADJ ADJACENT MECH MECHANICAL ARCH ARCHITECTURAL MIN MINIMUM BLDG BUILDING NTS NOT TO SCALE BM BEAM O.C. ON CENTER BOT BOTTOM OPT OPTIONAL BRIG BEARING OSB ORIENTED STRAND BOARD Cl CONTROLJOINT PLY PLYWOOD CL CENTERUNE PSI POUNDS PER SQUARE INCH CMU CONCRETE MASONRY UNIT PSF POUNDS PER SQUARE FOOT COL COLUMN PT PRESSURETREATED CONC CONCRETE REINF REINFORCEMENT COND CONDITION READ REQUIRED CONT CONTINUOUS RO ROUGH OPENING CONST CONSTRUCTION RTU ROOFTOP UNIT CLG CEILING SCH SCHEDULE DBL DOUBLE SHTHG SHEATHING DIA DIAMETER SIM SIMILAR DR DOOR SMS SHEET METAL SCREWS DWG DRAWING SP SOUTHERN YELLOW PINE EA EACH SPF SPRUCE PINE FIR EJ EXPANSIONJOINT STL STEEL ELECT ELECTRICAL STR STRUCTURAL FOR ENGINEER OF RECORD SGD SLIDING GLASS DOOR EQUIP EQUIPMENT SQ SQUARE FF FINISH FLOOR T&G TONGUE AND GROOVE FT FOOT/ FEET TOB TOP OF BEARING GA GAUGE TYP TYPICAL GC GENERAL CONTRACTOR LINO UNLESS OTHERWISE NOTED GYP GYPSUM VERT VERTICAL HGT HEIGHT W/ WITH HORIZ HORIZONTAL WIC WALK IN CLOSET HB HOSE BIB WO WOOD INS INSULATION WWF WELDED WIRE FABRIC KSI KIPS PER SQUARE INCH W/O WITHOUT MAS MASONRY WOW WINDOW SCOPE OF WORK 1. ADD A COVERED PORCH TO THE REAR OF THE STRUCTURE PER THE PLANS. A LARGE PORTION OF THIS NEW ROOF SYSTEM SHALL EXTEND OVER THE EXISTING ROOF SYSTEM TO PLANE OUT THE ROOF LINES. Sheet List Page No Sheet Name Sheet Number 1 General Notes SO.1 2 Existing and Proposed Floor Plans and Elevations S1.1 3 Foundation Plan S2.1 4 Roof Framing Plan a g S3.1 5 Roof Framing Sections S3,2 6 Section and Details S4.1 _ 2. 1. DESIGN CODE A. TO THE BEST OF THE DESIGN PROFESSIONALS KNOWLEDGE, THESE DOCUMENTS HAVE BEEN PREPARED WITH AND ARE IN COMPLIANCE WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE SAFETY STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH CHAPTERS 553 AND 633 OF THE FLORIDA STATUTES. THESE DOCUMENTS MEET OR EXCEED THE REQUIREMENTS OF: , a. 2017 FLORIDA BUILDING CODE, SIXTH EDITION, BUILDING, FBC. b. 2017 FLORIDA BUILDING CODE, SIXTH EDITION, RESIDENTIAL, FBC-R. C. 2017 FLORIDA BUILDING CODE ENERGY, FBC-E. d. 2014 NATIONAL ELECTRIC CODE, NEC 2014. } e. 2017 FLORIDA PLUMBING CODE, FBC-P. f. 2017 FUEL GAS CODE, FBC-FG. - a g. FLORIDA FIRE PREVENTION CODE, SIXTH EDITION, FFPC. F h. NATIONAL FIRE PROTECTION ASSOCIATION NFPA. 2. DESIGN CRITERIA A. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH AMERICAN CONCRETE INSTITUTE (ACI) 318 AND 332. _ B. ALL MASONRY WORK SHALL BE IN ACCORDANCE WITH ACI 530/530.1: AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE); TMS 402. C. REINFORCING STEEL SHALL BE IN ACCORDANCE WITH ACI 318. D. ALL WOOD FRAMING SHALL BE IN ACCORDANCE WITH THE LATEST EDITIONS LISTED IN THE FLORIDA BUILDING CODE OF THE FOLLOWING REFERENCED DOCUMENTS: 1. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION BY THE AMERICAN WOOD FOREST AND PAPER ASSOCIATION (AFPA) 2. TIMBER CONSTRUCTION MANUAL BY THE AMERICAN INSTITUTE OF TIMBER CONSTRUCTION 3. NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD TRUSSES (ANSI:TPI-1 BY TRUSS PLATE INSTITUTE (TPI)) 4. GUIDE TO WOOD PRACTICE FOR HANDLING INSTALLING AND BRACING OF METAL PLATE CONNECTED WOOD S. TRUSSES (SCSI 1: BY TPI AND WTCA) 5. ROOF AND WALL SHEATHING SHALL BE IN ACCORDANCE WITH APA PSI-95 OR NER-108D. 6. AMERICAN WOOD PROTECTION ASSOCIATION STANDARDS. 3. DESIGN LOADS A. ROOF DEAD LOAD: a. TOP CHORD (ROOF) 17 (SHINGLE) D (CEILING) 10 PSF GYPSUM b. BOTTOM CHORD (C ) (GYPSUM) B. ROOF LIVE LOAD: 20 PSF C. DEAD LOAD FOR UPLIFT CALCULATION: 10 PSF D. ATTIC LIVE LOAD 10 PSF 4. STRUCTURE SPECIFICATION A. BUILDING OCCUPANCY CATEGORY: II B. CONSTRUCTION TYPE: V-B C. OCCUPANCY CLASSIFICATION: R-3 D. WIND SPEED a. ULTIMATE (LRFD) = 160 MPH b. ALLOWABLE (ASD) = 124 MPH E. WIND EXPOSURE CATEGORY: C F. ENCLOSURE CLASSIFICATION: ENCLOSED G. INTERNAL PRESSURE COEFFICIENT: +/-0.18 H. WIND-BORNE DEBRIS AREA: YES I. REFER TO DRAWINGS FOR STRUCTURE HEIGHT AND AREA J. STRUCTURAL LOADS AND DESIGN PRESSURES LISTED IN THESE PLANS ARE ALLOWABLE (ASD) UNLESS NOTED OTHERWISE. S. PROJECT REQUIREMENTS'. A. THESE PLANS SHALL REMAIN ON THE PROJECT AT ALL TIMES. B. THE CONTRACTOR AND SUB -CONTRACTORS SHALL STRICTLY ADHERE TO ALL APPLICABLE CODES DURING THE COURSE OF CONSTRUCTION, INCLUDING ALL STATE, CITY AND COUNTY BUILDING, ZONING, ELECTRICAL, MECHANICAL, PLUMBING AND FIRE CODES, AS WELL AS ANY APPLICABLE HOMEOWNER ASSOCIATION REQUIREMENTS, C THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND SHALL NOTIFY THE DESIGN PROFESSIONAL OF RECORD OF ANY DISCREPANCIES OR CONFLICT WITH APPLICABLE CODES PRIOR TO CONSTRUCTION, D. THE ARCHITECT / ENGINEER SHALL NOT BE RESPONSIBLE FOR SAFETY PROCEDURES, THE MEANS AND METHODS OF CONSTRUCTION, TECHNOLOGIES OR THE FAILURE OF THE CONTRACTOR TO COMPLETE THE WORK IN ACCORDANCE WITH DRAWINGS, SPECIFICATIONS OR THE RELATED CODES. E. THE CONTRACTOR SHALL FULLY REVIEW ALL ITEMS CONTAINED IN THE DRAWINGS AND SHALL COORDINATE ALL DIMENSIONS, LOCATE DEPRESSED SLABS, SLOPES, DRAINS, OUTLETS, RECESSES,EMBEDS, SLEEVES, ETC, F. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE ERECTION PROCEDURES AND SEQUENCING. THE GENERAL CONTRACTOR 15 RESPONSIBLE FOR HIRING A DESIGN PROFESSIONAL FOR TEMPORARY SHORING OR LIFTING PROGRAMS. G. NOTES, DETAILS, AND SECTIONS ON THE DRAWINGS ARE SHOWN AT SPECIFIC LOCATIONS AND ARE INTENDED TO SHOW GENERAL REQUIREMENTS THROUGHOUT. "TYPICAL' DETAILS SIMPLY REFER TO ALL CONDITIONS TREATED SIMILARLY. CONTRACTOR SHALL MAKE MINOR MODIFICATIONS TO ACCOMMODATE MINOR SIMILAR VARIATIONS. H. THE CONTRACTOR SHALL MAKE NO STRUCTURAL CHANGES OR MODIFICATIONS WITHOUT EXPRESSED WRITTEN APPROVALOF THE ENGINEER OF RECORD IN ADVANCE. SITE WORK: 1. SOIL A. ALL WORK SHALL CONFORM TO THE FINAL GEOTECHNICAL REPORT AND THE FINAL GRADING PLAN ACCEPTED BY THE AUTHORITY HAVING JURISDICTION. B. IF THE SOILS REPORT IS NOT AVAILABLE, SOIL BEARING CAPACITY IS ASSUMED TO BE A MINIMUM OF 1,800 PSF. C. CONTRACTOR SHALL VERIFY COMPACTION REQUIREMENTS PRIOR TO THE EXECUTION OF WORK. DISCREPANCIES SHALL BE BROUGHTTO THE ATTENTION OF THE DESIGN PROFESSIONAL PRIOR TO COMMENCEMENT OF WORK. D. FOOTINGS SHALL BE PLACED ON UNDISTURBED SOIL OR COMPACTED FILL, FREE OR ORGANIC MATTER AND COMPACTED TO 95%OF THE MODIFIED PROCTOR, UNLESS OTHERWISE NOTED IN THE GEOTECHNICAL REPORT. E. THE SOILS WITHIN 15 FEET OF THE PROPOSED BUILDING PAD SHALL BE FREE OF ANY WOOD, VEGETATION. STUMPS, CARDBOARD, TRASH, OR OTHER DELETERIOUS MATERIAL. F. WATER MANAGEMENT ATTHE PERIMETER SHALL BE MAINTAINED AND SHALL INCLUDE: a. CONDENSATE DRAINS AND ROOF DOWN SPOUTS SHALL DISCHARGE AT LEAST 12" FROM BUILDING. b. IRRIGATION /SPRINKLER SYSTEMS, INCLUDING ALL RISERS AND SPRAY HEADS SHALL NOT BE INSTALLED WITHIN 16" OF BUILDING. C. LANDSCAPE SHALL BE INSTALLED AT LEAST 24" AWAY FROM BUILDING PERIMETER. G. ANY FILL BROUGHTTO THE SITE SHALL MEET PROJECT REQUIREMENTS OF THE GEOTECHNICAL ENGINEER. SOIL TREATMENT A. TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES BAITING SYSTEMS, AND/OR PESTICIDES APPLIED TO WOOD OR OTHER APPROVED METHODS. B. BOXED AREAS IN CONCRETE FLOORS FOR INSTALLATION OF TRAPS, ETC. SHALL BE MADE WITH PERMANENT METAL OR APPROVED PLASTIC FORMS. FORMS SHALL BE OF A SIZE AND DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF SOIL AFTER INITIAL TREATMENT. C. PROVIDE VAPOR BARRIER IMMEDIATELY FOLLOWING SOIL TREATMENT. D. A LICENSED PEST CONTROL COMPANY SHALL SUBMIT A CERTIFICATE OF COMPLIANCE TO THE BUILDING DEPARTMENT AT COMPLETION OF TREATMENT. E. AFTER COMPLETION OF WORK, ALL LOOSE WOOD, CONSTRUCTION DEBRIS, AND ORGANIC MATERIAL SHALL BE REMOVED FROM WITHIN 16" OF BUILDING PERIMETER. ;BETE: CONCRETE A. ALL WORK SHALL BE MIXED, PLACED, AND CURED IN ACCORDANCE WITH THE AMERICAN CONCRETE INSTITUTE ACI 318. B. CONCRETE SHALL HAVE THE FOLLOWING SPECIFICATIONS UNLESS NOTED OTHERWISE: AREA STRENGTH (PSI) SLUMP AGGREGATE SIZE SLAB 3,000 PSI (28 DAYS) 4"-6" 3/4"-2" FOOTERS 3,000 PSI (28 DAYS) 4"-6" 3/4" - 2" C. GENERAL CONTRACTOR SHALL SUBMIT MIX DESIGN TO THE ENGINEER OF RECORD FOR REVIEW AND APPROVAL PRIOR TO PLACING ANY CONCRETE. D. MATERIAL FOR CONCRETE SHALL CONFORM TO THE FOLLOWING: a. PORTLAND CEMENT-ASTM C150 b. AGGREGATES: COURSE AGGREGATE: ASTM C33, LIGHTWEIGHT: ASTM C330, FINE: ASTM C33 E. WATER SHALL BE FREE OF CONTAMINANTS, CLEAN AND. POTABLE. F. WATER SHALL NOT BE ADDED TO THE MIX ONSITE UNLESS SPECIFICALLY APPROVED IN THE MIX DESIGN SPECIFICATIONS PER THE SPECIFIED VOLUME. G. ADMIXTURES SHALL CONFORM TO THE MIX DESIGN. TESTING AND SAMPLING A. ALL TESTING SHALL BE DONE BY AN INDEPENDENT TESTING LABORATORY IN ACCORDANCE WITH ASTM REQUIREMENTS. TEST REPORTS SHALL BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO FURTHER CONSTRUCTION. B THREE CYLINDER TE T AMPLES SHALL BE MADE DURING EACH DAYS SEQUENCE PE R EVERY 50YAR S. TWO TESTS (PER ASTM C143) SHALL BE PERFORMED AND RECORDED FOR EACH BATCH, ONE AT THE BEGINNING AND ONE ATTHE END. a. ONE CYLINDER SHALL BE BROKEN AT 7 DAYS AND ONE AT 28 DAYS. RESERVE CYLINDER WILL BE NEEDED IF SECOND TEST FAILS SPECIFICATIONS. C. SUBMIT TEST RESULTS TO ENGINEER OF RECORD WITHIN FIVE DAYS OF RESULTS. GROUT A. GROUT SHALL BE IN ACCORDANCE WITH ASTM C476 HAVING A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI. B. CONTRACTOR SHALL ADD PLASTICIZER TO GROUT MIXTURE C. FILL CMU CELLS SOLID WITH GROUT ATALL UNITS RECEIVING REINFORCEMENT AND AS NOTED ON DRAWINGS AND SECTIONS. D. FILL SOLID FIRST COURSE BELOW CHANGE IN WALL THICKNESS AND ATTOP OF ALL CMU WALLS. E. GROUT SHALL BE PLACED FLUSH TO THE TOP OF ALL UNTELS AND BOND BEAMS. CONSOLIDATE AND RE -CONSOLIDATE GROUT WITH VIBRATOR FOR FULL HEIGHT OF FILLED CELLS, BOND BEAMS, AND LINTELS. REINFORCING A. REINFORCING SHALL HAVE GRADE IDENTIFICATION MARKS AND SHALL CONFORMTO ASTM A615, GRADE 60. B. REINFORCING SHALL BE FREE OF RUST, SCALE OR OTHER BOND REDUCING COATINGS. C. REINFORCING SHALL BE PLACED IN CONCRETE TO PROVIDE MINIMUM COVERAGE IN ACCORDANCE WITH ACI 318 OR AS INDICATED IN THE DRAWINGS. a. CONCRETE CASTAGAINSTAND PERMANENTLY EXPOSED TO EARTH - 3" b. CONCRETE EXPOSED TO EARTH OR WEATHER - 1.5" C. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND-3/4" D. MINIMUM LAP SPLICE (UNLESS NOTED OTHERWISE) BAR SIZE MASONRY CONCRETE 1500 PSI 2000 PSI 3000 PSI 4000 PSI #4 24" 21" 27" 15" #5 30' 26" 21" 19" #6 36' 31" 26" 22" #7 42' 46" 37" 32" #8 48" 53" 43" 37" E. ACCURATELY PLACE AND SUPPORT REINFORCING WITH CHAIRS, BAR SUPPORTS, SPACERS, OR HANGERS AS RECOMMENDED BY ACI DETAILING MANUAL. F. PLACE (1) ONE ACI STANDARD LAP SPLICE BAR, OF THE SAME SIZE AS FOUNDATION REINFORCING, LOCATED AT THE OUTSIDE BAR OF FOUNDATION CORNERS. G. WELDED WIRE MESH IF USED SHALL BE IN ACCORDANCE WITH ASTM A85 AND SHA LL BE 6x6-W1.4xW1.4, UNLESS NOTED OTHERWISE ON DRAWINGS. a. INSTALL WELDED WIRE MESH IN THE MIDDLE OF THE SLAB AND SUPPORT WITH APPROVED MATERIALS OR SUPPORTS AT SPACING NOT TO EXCEED THREE FEET ON CENTER OR IN ACCORDANCE WHTTHE MANUFACTURERS SPECIFICATION. b. LAP ALL JOINTS IN WELDED WIRE MESH 12 INCHES. H. FIBER MESH, IF USED IN LIEU OF WELDED WIRE MESH SHALL BE 2.1 LES PER CUBIC YARD UNLESS NOTED OTHERWISE. PLACEMENT AND FINISHING A. ALL CONCRETE PLACED UNDER ROOF PROTECTION SHALL BE PLACED OVER 6 MIL POLYETHYLENE VAPOR BARRIER, LAPPED 8 INCHES MINIMUM WITH ALL SEAMS TAPED UNLESS NOTED OTHERWISE. B. PLACE ALL EMBEDDED ITEMS (ANCHOR BOLTS, DOWELS, ETC.) IMMEDIATELY PRIOR TO PLACEMENT OF CONCRETE OR DURING CONCRETE OPERATIONS. C. PROTECT ALL CONCRETE FROM DAMAGE AFTER PLACEMENT. D. CONCRETE SHALL BE PLACED WITHIN 90 MINUTES OF BATCHING UNLESS MIX DESIGN SPECIFIES OTHERWISE. E. CONCRETE SHALL BE PLACED WITHIN THE SLUMP LIMITS SPECIFIED IN THE DESIGN MIX, F. WATER ADDED AT THE SITE SHALL BE KEPT TO A MINIMUM AND WITHIN THE SPECIFIED SLUMP. RUN MIXER FOR THIRTY REVOLUTIONS AT 8-12 RPM FOLLOWING THE ADDITION OF WATER AT THE SITE. G. CONCRETE SHALL NOT BE PLACED DURING RAIN. FOLLOWING PLACEMENT OF CONCRETE, PROTECT FROM RAIN PRIOR TO INITIAL SET. H. PLACEMENT SHALL BE CONTINUOUS UNTIL ALL WORK IS COMPLETED. I. DO NO USE CONTAMINATED, DETERIORATED, OR RETEMPERED CONCRETE. 1. THOROUGHLY WORK CONCRETE AROUND REINFORCING BARS. K. PLACE CONCRETE TO GRADES AND ELEVATIONS REQUIRED FOR PROJECT. L. REMOVE ALL GRADE STAKES AFTER PLACEMENT OF CONCRETE. M. AT SLABS GREATER THAN 20 FEET IN ANY DIRECTION a. PROVIDE SAW CUT CONTROL JOINTS IN CONCRETE AFTER INITIAL SET AND PRIOR TO HARDENING b. SAWCUT JOINTS SHALL BE I/3 THE DEPTH OF THE SLAB. t. ANY SLAB EXCEEDING 20 FEET SHALL BE DIVIDED AT ALL CORNERS AND SHALL EXTEND IN EACH 90 DEGREE DIRECTION. N. PROVIDE SURFACE FINISH REQUIRED FOR INTENDED FINAL APPLICATION. 0. SILL PLATE ANCHORS SHALL BE AS SPECIFIED IN SPECIFICATIONS. P. CONSOLIDATE CONCRETE THOROUGHLY DURING CONCRETE OPERATIONS. Q. CURE CONCRETE FOR THREE DAYS TO MINIMIZE SHRINKAGE CRACKS. Category -Subcategory Approval Dof)ng Shingles FL10674-RJ nnfina- IlndarInumant FI t6n6R-Rf MASONRY: 1. MATERIALS A. ALL HOLLOW LOAD BEARING CONCRETE BLOCK SHALL CONFORM TO ASTM C90, GRADE N, TYPE 11. B. COMPRESSIVE STRENGTH OF ALL CONCRETE MASONRY UNITS (CMU) SHALL BE 2000 PSI MINIMUM BASED ON THE NET CROSS SECTIONAL AREA. C. MORTAR SHALL BE TYPE S AND SHALL CONFORM TO ASTM C270. D. GROUTING SHALL BE AS SPECIFIED IN NOTES. 2. EXECUTION A. ALL CONCRETE MASONRY UNITS SHALL BE LAID IN FULL SETTING BED AND IN RUNNING BOND UNLESS NOTED ON DRAWINGS. B. ALL EXTERIOR MASONRY WALLS SHALL HAVE 9 GAUGE "LADDER TYPE" HORIZONTAL REINFORCEMENT LOCATED EVERY 16" ON CENTER VERTICAL. CORNERS SHALL USE PRE-FAB "L" AND "T" SECTIONS. C. OVER ALL MASONRY OPENINGS AND WALLS, PROVIDE PRE -CAST LINTELS, CASTAN-PLACE CONCRETE TIE -BEAMS, BOND BEAMS, OR OTHER HEADERS AS INDICATED ON DRAWINGS. a. LINTELS AND BOND BEAMS SHALL BE REINFORCED AND FULL GROUTED SOLID UNLESS OTHERWISE INDICATED ON DRAWINGS. b. TIE -BEAMS SHALL BE REINFORCED AND POURED SOLID WITH CONCRETE C. VERTICAL REINFORCING AT OPENINGS SHALL BE AS INDICATED ON DRAWINGS. D. VERTICAL FILLED CELLS SHALL MEET THE FOLLOWING: a. HAVE A MINIMUM OF ONE #5 REBAR, LAPPED FOR FULL LENGTH OF FILLED CELL b. VERTICAL REINFORCING SHALL BE LAPPED TO FOUNDATION DOWEL EMBEDDED IN FOOTING. C. TERMINATE VERTICAL REINFORCING ATTHE TOP WITH A STANDARD ACI HOOK, LAPPED TO HORIZONTAL REINFORCING IN BOND BEAM, TIE -BEAM, OR LINTEL. d. REFER TO CONCRETE NOTES FOR GROUT AND REINFORCEMENT REQUIREMENTS. E. PROVIDE TEMPORARY BRACING FOR ALL CMU WALLS AND STEM WALLS DURING CONSTRUCTION. F. PROVIDE MASONRY CONTROL JOINTS AS REQUIRED BY ACI 530. G. IF DOWELS ARE MISPLACED OR MISSING, THE FOLLOWING REMEDIAL ACTION SHALL BE TAKEN AS APPROPRIATE: a. IF THE WALL HAS NOT BEEN BUILT; DRILL A 3/n' DIAMETER HOLE 6" DEEP AT THE CORRECT LOCATION, INSTALLA 36" LONG #5 REBAR WITH SIMPSON TIE "SET EPDXY". FOLLOW THE MANUFACTURERS REQUIREMENT REQUIRING CLEANING THE HOLE AND MIXING THE EPDXY. b. IF THE WALL HAS BEEN BUILT: PRIOR TO LINTEL POUR OPEN THE WALL AT THE CORRECT LOCATION, APPROXIMATELY 16" HIGH AND 14" WIDE AT THE FLOOR, DRILL AND EPDXY THE REBAR AS DESCRIBED ABOVE, LAP VERTICAL STEELTO THE TIE OR BOND BEAM. FORM WALL AND POUR SOLID WITH GROUT, CONSOLIDATING AS NECESSARY. H. CURE MASONRY SURFACES FOR 3 DAYS. WOOD FRAMING COMPONENTS: LUMBER 1. MATERIALS A. ALL WOOD AND WOOD CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING SPECIFICATIONS AND CODES INDICATED IN THE DESIGN CRITERIA: B. LUMBER SHALL BE IN ACCORDANCE WITH THE NATIONAL GRADING RULES AND SHALL BEAR GRADE STAMP OF SPIB, OR OTHER ASSOCIATION RECOGNIZED BY THE AMERICAN INSTITUTE OF TIMBER CONSTRUCTION. C. LUMBER 2" OR LESS IN NOMINAL THICKNESS SHALL NOT EXCEED 19% IN MOISTURE CONTENT AT THE TIME OF INSTALLATION AND SHALL BE STAMPED "S-DRY", "K-D", OR "MC15". ALL LUMBER SHALL BE S4S. D. ALL ROOF FRAMING MEMBERS ABOVE THE CEILING LINE SHALL BE SOUTHERN PINE #2 GRADE OR BETTER. E. INTERIOR BEARING AND EXTERIOR WOOD FRAMED WALL SHALL BE SPF #2, OR BETTER, UNLESS NOTED OTHERWISE ON DRAWINGS. F. INTERIOR NON -BEARING WALL MAY BE 2x's WOOD OR LIGHT GAUGE METAL STUDS AT 24" ON CENTER. 2. EXECUTION A. WOOD FASTENING SHALL BE SPECIFIED IN THE DRAWINGS. B. FASTENING NOT SPECIFICALLY IDENTIFIED ON DRAWINGS SHALL COMPLY WITH THE REQUIREMENTS OF THE BUILDING CODE. C. INTERIOR BEARING AND EXTERIOR WOOD FRAMED WALLS SHALL BE NOMINAL 41NCHES WIDE SPACED AT 16" ON CENTER MAXIMUM, UNLESS NOTED OTHERWISE ON THE DRAWINGS. D. DOUBLE TOP PLATES OF FRAMED WALLS SHALL BE LAPPED 24 INCHES MINIMUM. E. USE LEGEND BELOW FOR CONVENTIONAL FRAME AND OVER -BUILT FRAMING MEMBERS AND CONNECTIONS, SPACING BELOW IS 24" ON CENTER. RAFTER 2x4 SYP 2x6 SYP 2x8 SYP 2x10 SYP 2x12 SYP MAX. SPAN 5'-0" 8'-0" 12--0" 15'-0" 19'-0" F. RIDGE AND VALLEY MEMBERS SHALL HAVE A NOMINAL DEPTH OF 2 INCH LARGER THAN RAFTERS AND SHALL BE TWO PLY FOR MEMBERS LONGER THAN 16'-0". G. HEADERS SHALL BE AS SPECIFIED IN HEADER SCHEDULE WITH STUDS AND STRAPPING SPECIFIED HEADERS SHALL BE SOUTHERN PINE #2 OR BETTER, MINIMUM HEADER UNLESS NOTED OTHERWISE SHALL BE (2) 2x12. H. A BUILT UP OR SOLID SAWN COLUMN SHALL BE INSTALLED UNDER GIRDERS AND / OR BEAMS IN BEARING WALLS AS NOTED ON DRAWINGS. I. SQUASH BLOCKS SHALL BE INSTALLED BELOW ALL COLUMNS AND BUILT UP MEMBERS (INCLUDING JACKS AND KINGS AT OPENINGS) BETWEEN BOTTOM OF FLOOR SHEATHING AND TOP OF WALL BELOW. SQUASH BLOCKS SHALL BE OF THE SAME GRADE AND SIZE OF THE MEMBER ABOVE. 1. DRAFT STOPPING SHALL BE INSTALLED WHERE THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE TO 1000 SQUARE FEET. a. DRAFT STOPPING SHALL BE INSTALLED IN APPROXIMATELY EQUAL AREAS TO LIMITTHE CONCEALED SPACE OF A FLOOR / CEILING ASSEMBLY. b. DRAFT STOPPING SHALL BE OF NOT LESS THAN 1/i `GYPSUM BOARD, 3/8" WOOD STRUCTURAL PANELS, 3/8" TYPE 2- M-W PARTICLE BOARD. C. DRAFT STOPPING SHALL BE INSTALLED PARALLEL TO FLOOR FRAMING MEMBERS. K. FIREBLOCKING SHALL BE INSTALLED AT ALL HORIZONTAL AND VERTICAL DRAFT OPENINGS. a. BLOCKING SHALL BE IN THE FOLLOWING LOCATIONS: • CONCEALED SPACED OF STUD WALLS AND PARTITIONS. • VERTICALLY ATCEILING AND FLOOR LEVELS. • HORIZONTALLY AND INTERVALS EXCEEDING 10 FEET. • BETWEEN HORIZONTAL AND VERTICAL SPACES SUCH AS SOFFITS, DROP CEILINGS AND CO -CEILINGS. UN VENTS, PIPES, CABLES, AN • AT OPEN1 G AR N S O D E D WIRES AT CEILINGS AND FLOOR LEVELS. b. FIREBLOCKING SHALL BE: 21NCH NOMINAL LUMBER, OR • ONE THICKNESS OF 23132" WOOD STRUCTURAL PANELS WITH JOINTS BACKED WITH 23/32" WOOD STRUCTURAL PANELS, OR • 1/," GYPSUM BOARD, OR • OTHER APPROVED MATERIALS PER THE CODE. SHEATHING: 1. MATERIALS A. SHEATHING SHALL BE IN ACCORDANCE WITH PS 1-09 / ANSI A 199.1. ALL SHEETS SHALL BEAR APPROPRIATE GRADING STAMP OF APA AND SPAN RATING. B. SHEATHING SHALL NOT EXCEED 19%MOISTURE CONTENT WHEN INSTALLED. DO NOT INSTALL VAPOR/MOISTURE BARRIERS ON SHEATHING AFTER A RAIN EVENT UNTIL THE MOISTURE CONTENT DROPS BELOW 19%. C. FLOOR SHEATHING SHALL BE A MINIMUM OF 23/32" 24/16 SPAN RATED STRUCTURAL SHEATHING FOR 16" ON CENTER SPACING OR 48/24 FOR SPACING GREATER THAN 16" ON CENTER. D. WALL SHEATHING SHALL BE 24/16 SPAN RATED STRUCTURAL SHEATHING. E. ROOF SHEATHING SHALL BE AS NOTED IN THE ROOF SHEATHING AND ATTACHMENT SCHEDULE. 2. EXECUTION A. SHEATHING SHALL HAVE GAP AT ALL EDGES FOR EXPANSION AND CONTRACTION AT ALL EDGES UNLESS NOTED OTHERWISE. B. FLOOR SHEATHING SHALL BE INSTALLED WITH FACE GRAIN PERPENDICULAR TO SUPPORTS GLUED AND SCREWED WITH #10 SCREWS AT 6" ON CENTER. C. ROOF SHEATHING SHALL BE FASTENED AS SPECIFIED IN THE DRAWINGS. ADD BLOCKING AT ALL PANEL EDGES IN ZONE 3 (CORNERS). Florida Product Approval Listings Building Design Pressures Manufacturer Model Number (+PSF/-PSF) wnes Corning Duration 160 MPH ULT wnes Corning ITri Built Roof Underlayments N/A PRODUCT APPROVAL NOTE: I HAVE REVIEWED THE ABOVE COMPONENTS OR CLADDING AND I HAVE APPROVED THEIR USE IN THIS STRUCTURE. THESE PRODUCTS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS SPECIFIED BY CURRENT CODE PROVISIONS. HARD COPIES OF THE PRODUCT APPROVALS SHALL BE AVAILABLE ON SITE FOR INSPECTION$. Product Design Pressures (+PSF / -PSF) 160 MPH ULT N/A PRE-ENGINEERED WOOD TRUSSES: Project Number: 1. GENERAL 18A095 A. NO MODIFICATIONSTO THETRUSS LAYOUTSHOWN ON THIS PLAN SHALL BE MADE WITHOUTTHE APPROVAL OF THE ENGINEER OF RECORD; D. TRUSS MANUFACTURER SHALLVERIFY ALL DIMENSIONS AND SUBMITSHOP DRAWINGS WITH CALCULATIONS SIGNED BY B. ALL TRUSSESANO TRUSS DETAILS SHALL BE DESIGNED, SPECIFIED, AND CERTIFIED BY THE REGISTERED ENGINEER OF THE TRUSS MANUFACTURER. ar C. TRUSS TO TRUSS CONNECTIONS SHALL BE THE RESPONSIBILITY OF THE TRUSS MANUFACTURER. O FLORIDA REGISTERED TRUSS ENGINEER TO THE ENGINEER OF RECORD AND GENERAL CONTRACTOR FOR APPROVAL PRIOR TO FABRICATION. E. TRUSS DESIGN AND FABRICATION SHALL COMPLY WITH TRUSS PLATE INSTITUTE (TPI). F. TRUSS MANUFACTURER TO FOLLOW GABLE END DETAIL FOR ADDITIONAL LOADING REQUIREMENTS (AS OCCURS). 2. MATERIALS A. TRUSS MANUFACTURER SHALL DESIGN ALLTRUSSES AND TRUSS COMPONENTS FOR LOADS SPECIFIED IN NOTES. B. TRUSSES SHALL BE DELIVERED TO THE PROJECTSITE WITH THE FOLLOWING MINIMUM DOCUMENTATION SUPPLIED BYTHE c TRUSS MANUFACTURER. O a. GABLE END BRACING DETAILS AND RECOMMENDATIONS 2 b. LATERAL BRACING AND RESTRAINT DETAILS U C. CONTINUOUS LATERAL BRACING (CLB) INSTALLATION REQUIREMENTS p d. PIGGYBACK INSTALLATION DETAILS e. CONVENTIONAL FRAMED VALLEY DETAIL f. TOE NAIL DETAIL FOR JACK TRUSSES g. TWO PLY CONNECTION DETAIL 3. EXECUTION A. ERECTION OF TRUSSES SHALL BE IN ACCORDANCE WITH THE BUILDING COMPONENTS SAFETY INFORMATION PUBLICATION, BCSI 1-15. THE ERECTION CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER WOOD TRUSS HANDLING AND FOR PROPER TEMPORARY AND PERMANENT BRACING. TRUSSES SHALL BE MAINTAINED IN PROPER ALIGNMENT AND SHALL NOT BE o STRUCTURALLY DAMAGED. Z B. TRUSSES ARE NOT SAFE OR STABLE UNTIL ALL SHEATHING, CONNECTORS, AND BRACING HAS BEEN INSTALLED. CONTRACTOR SHALL NOT REMOVE SHORING UNTIL SYSTEM IS COMPLETE, C. TRUSSES SHALL BE INSTALLED AS INDICATED IN THE LAYOUT SUPPLIED BY THE TRUSS MANUFACTURER AND NOT LESS THAN � LU LU � (" 24" ON CENTER. O (n N F_ D. PERMANENT 2x4 HORIZONTAL BRACING SHALL BE INSTALLED ON TOP OF THE BOTTOM CHORDS OF ALL ROOF TRUSSES WITH SPANS GREATER THAN 10'. BRACING SHALL BE NAILED WITH (2) 10d NAILS AT EACH TRUSS AND SPACED NO MORE THAN 10' ON CENTER. E. FLOOR FRAMING SHALL BE PRE-ENGINEERED FLOOR TRUSSES OR MANUFACTURED LUMBER SPACED AT 24" ON CENTER MAXIMUM, UNLESS NOTED OTHERWISE ON DRAWINGS. F. FLOOR FRAMING SHALL BE LOCATED TO ACCOMMODATE MECHANICAL AND ELECTRICAL LAYOUT. } m FASTENERS: LU co0 1. MATERIALS Q LU A. WOOD CONNECTORS AND HOLD-DOWNS SHALL BE AS SPECIFIED IN THE DRAWINGS AND SHALL BE INSTALLED IN Ln z ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. LU W B. CONNECTORS FOR TRUSS TO TRUSS COMPONENTS SHALL BE SPECIFIED PER THE TRUSS MANUFACTURER. yam) Q < W C. FASTENERS AND CONNECTORS USED ON UN -TREATED WOOD EXPOSED TO THE WEATHER SHALL BE HOT DIPPED GALVANIZED N Lr)) 0 IY OR STAINLESS STEEL. D. FASTENERS AND CONNECTORS (INCLUDING TRUSS PLATES, NAILS, BOLTS, ANCHORS, ETC.) USED IN CONTACT WITH TREATED WOOD SHALL BE COMPATIBLE WITH THE TREATMENT METHOD AND AS FOLLOWS: COL 3:12-17 a. WOOD TREATED WITH DOTSODIUM BORATE - MINIMUM G90 ZINC COATING b. WOOD TREATED WITH AC -C OR AC -D OR Q Q OTHER BORATE (NON -DOT) -MINIMUM G185 ZINC COATING LnC. FOR ALL OTHER TREATMENT- COMPLY WITH THE RECOMMENDATIONS OF THE PRESERVATIVE WOOD SUPPLIER Ln d. STAINLESS STEEL CONNECTORS MAYBE USED FOR ANY TYPES OF TREATED OR UNTREATED WOOD Ur 2. EXECUTION Z CO A. HANGARS AND FRAMED COMPONENTS SHALL BE FURNISHED BY THE MANUFACTURER WITH NAILS FOR SPECIFIC USE AND LU 0 INSTALLATION. ~ � V B. ALL PRE -MANUFACTURED CONNECTORS SHALL HAVE NAILS / SCREWS / ANCHORS INSTALLED IN ACCORDANCE WITH THE I W O) J CONNECTOR SCHEDULE AND MANUFACTURERS SPECIFICATIONS, FILLY DRIVEN. w N Q C. ALL SOLE PLATES SHALL BE AS DESCRIBED HEREIN AND SHALL MEET THE FOLLOWING: U Z Ln > J 0) a. ALL ANCHOR BOLTS SHALL HAVE 2N2"x1/a" PLATE WASHERS UNLESS NOTED OTHERWISE. _ rJ J �'1- It b. BOLTS SHALL BE LOCATED AT CORNERS AND JAMBS AND WITHIN 6" OF EACH END OR JOINT IN PLATE. N co S O c. PLATES LESS THAN 20 INCHES IN LENGTH SHALL HAVE ONE ANCHOR INSTALLED IN THE MIDDLE THIRD OF THE PLATE N Z � w Q m LL LENGTH. ILl Q � w N Q d. SLEEVE ANCHORS AND EXPANSION ANCHORS ARE NOT PERMITTED AT EXTERIOR WALLS. W V cc 02 h w D. REFER TO THE SOLE PLATE ANCHORAGE SCHEDULE ATTACHMENTS OF PLATE TO CONCRETE OR MASONRY. ■ z 0 r` Q LU U i Z) z F- STUCCO FINISHES: L2) Ln 1. GENERAL LLf) A. STUCCO SHALL MEE TASTM C926 AND ASTM C1063. cH B. STUCCO LATH SHALL BE Va " RIB GALVANIZED AND 3.5 LB/YD3. `. C. CEMENTITIOUS FINISH SHALL BE AS NOTED BELOW: a. 1/," THICK (FINISH) OVER MASONRY AS A TWO COAT SYSTEM b. s/a" THICK (FINISH) OVER CEILING SHEATHING AS A TWO COAT SYSTEM D.RTXTURE STUCCO PEIOWNER, 2. MATER{pOVER WALL SHEATHING ASATHREE COAT SYSTEM �/`J \° ti A. STUCCO ACCESSORIES (WEEP SCREED, EXPANSION JOINTS, CORNERS AND TRIM) SHALL BE PVC UNLESS NOTED OTHERWISE. 3. EXECUTION yoh 0 Ol A. PRIOR TO INSTALLATION, ALL FRAMING MEMBERS SHALL BE STRAIGHT AND TRUE WITHIN%". aW i B. ADD CONTROLJOINTS WITH BLOCKING WHERE WALL OR CEILING EXCEEDS FIFTY LINEAL FEET. w^U 21 ¢ p ° C. INSTALL CEILING BOARDS PERPENDICULAR TO THE FRAMING MEMBERS WITH'/s' GAP AT ALL EDGES. y°') z v�i v° O D. FASTENERS SHALL BE LOCATED NOT LESS THAN 3/e' FROM THE EDGE OR END AND SHALL BE DRIVEN SO THE HEADS ARE SLIGHTLY BELOW THE SURFACE WITHOUT BREAKING THE FACE PAPER, FRACTURING THE CORE, OR STRIPPING THE FRAMING E. CEILING SCREWS SHALL BE SPACED AT 6" ON CENTER MAXIMUM. STUCCO LATH SHALL BE ATTACHED TO THE FRAMING ,'fJ1! 11 11 0%`,,` MEMBERS AT 6" ON CENTER MAXIMUM. SCREWS USED TO ATTACH METAL PLASTER BASE TO HORIZONTAL AND VERTICAL WOOD FRAMING MEMBERS SHALL PENETRATE NOT LESS THAN s/e' INTO THE MEMBER WHEN THE LATH IS INSTALLED AND SHALL ENGAGE NOT LESS THAN THREE STRANDS OF LATH. WHEN INSTALLING RIB LATH, THE SCREW SHALL PASS THROUGH, 00 BUT NOT DEFORM, THE RIB, a, F. CONTROL (EXPANSION AND CONTRACTION) JOINTS SHALL BE INSTALLED TO DELINEATE AREAS NOT MORE THAN 100 SQUARE M FEET FOR ALL HORIZONTAL APPLICATIONS. THE DISTANCE BETWEEN CONTROL101NTS SHALL NOT EXCEED 18 FEET IN EITHER DIRECTION OR A LENGTH -TO -WIDTH RATIO OF 21/2 TO 1, A CONTROL JOINT SHALL BE INSTALLED WHERE THE CEILING FRAMING OR FURRING CHANGES DIRECTION. A CONTROL JOINT SHALL BE INSTALLED WHERE AN EXPANSION JOINT OCCURS IN z THE BASE EXTERIOR WALL. w 7 Q 0 Z LLI U 0 ® j Z L ry J W fO Z N d UJ Q W� _J Z Z C] T� W 2 Q Q 110 rn W 11J J LL SCANNED U BY LU °C St. Lucie ounty a L.LL General Notes REVIEWED FOR S0,11 CODE COMPLIANCE ST. LUCIE COUNT Y BOCC of - 6 V Ki RECELVEL JUL 10 1019 - FILto i4 1 Permitting Department R@, 6Utle County EXISTING OUTDOOR KITCHEN TO REMAIN I I 20' 6" 6' _ $ 1 19' _ 4 2 r------------ - ---- -- --- I I N I O rl I BI I � PATIO SLAB r - - - -- -� v 1095 SF b FIREPLACE I I I I ;[STING SQUARE FOOTAGE CALCS: VDER AIR 2,396 SF )RCHES / GARAGE 1,035 SF )TAL BUILDING AREA 3,431 SF PROPOSED SQUARE FOOTAGE CALCS: UNDER AIR 2,396 SF PORCHES / GARAGE 2,130 SF TOTAL BUILDING AREA 4,526 SF First Floor n (T-00" tight Elevation - Pro 1/81, = 1'-01, - 5 Left Elevation - Proposed St.1 1/8.,_ 1,_0„ 1 02 Proposed Floor Plan -Sl-1 1 /4�' = 1'-0" _Rear 10' - 0" b Proposed Isometric 51.1 - REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY Project Number: 18AO95 N 0 z w w IN— O N N � � � 4 N W ri d m 6i Q co W LU Ln z Ln — in LLU COOL 3:12-17 � 1 J Z co w Q ~o " I w N Q Z N ina ''nn co u, L7 M u or LL ■ w Q� w N Q WU cc:mr- = - z O Q w U rL O > K Z F- Ln Ln Ln } b 3 3" �oZ N ti W O O° We m uo� o a�°e asting ana vroposea Floor Plans and Elevations 51.1 a m in N N Z OF 6 N n 1 2 3 4 5 6 II I I I I I I 66' - 8" Ol Foundation Plan 1/4" = 1'-0" _ Foundation Schedule Mark WxDxL I Type Reinforcement P-1 48"x48"x16" Pad Footer - Concentric (4) #5 Bars Each Way at Bott. P-2 60 x60"x20" Pad Footer - Eccentric (6) #5 Bars Each Way Middle and Bott. Structural Column Schedule Mark Size I Type Reinforcement C-1 12"x12" IMasonry (4) #5 Vert. Bars w/ #5 Hoop at M1d. and Top Project Number: 18A095 00 a 0 C G 0 r .� U U U 0 0 G a -a c N h 2 0 z � � w w I— O Ln N � V \ K N w ri LL } m W on 0 0 Z UJI� = w w LA lQ- U7 in in Cr COOL 3:12-17 Ln d' 1 Z co w 0 o U I W Ol J V) rJ Q C] Z Lr) JLLa)ED In N L7 on U 0 ■ Z *t w Q M � W Q > W N Q W U � m n ad - z cc rLccE O > z ac L N en Ln Ld U Z W Q UJ X J U) 1w Z Q Z rwrn QUJ J Z Q WU' h � Z p 0 --J Ul Ln W G) r d' Foundation Plan 52.1 REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY 3 of 6 BOCC 00 0) RCT z D O U w 0 J N J L.L W U it w a M m N c-1 N 0 0 z'. 1/4" = 1'-0" A= 6' - 0" -- ---------------- r Y A EE OVERERAMING DETAIL O O J I EXISTING STRUCTURE Member Type/ Marl A - Girder Truss B - Typ. Truss Strap C - Truss to Exist Wall 3/32" = 1'-0" COMPONENTS AND CLADDING WIND PRESSURE FOR ROOF SHEATHING (PSF) ZONE 1- INTERIOR: +46 / -67 +27 / -40 6" O.C. ZONE 2 PERIMETER: +46 / -132 +27 / -79 6" O.C. ZONE 3-CORNER: +45/-172 +27/-103 4"O.C. NOTES: EDGE DISTANCE = 6'-0" THE EFFECTIVE AREA FOR ZONES 1 AND 2 ARE 32 SF. THE EFFECTIVE AREA FOR ZONE 3 IS 36 SF. ROOF SHEATHING SHALL BE 15/32" MIN. ATTACHMENT SHALL BE 10d COMMON OR RINGSHANK, FIELD AND EDGE SPACING SHALL BE THE SAME. Beam Schedule Mark Beam Beam Size Reinforcement _ _ Comment B-1 Precast Lintel 8F161T/1B (1) #5 Bar Horiz. Top and Bottom B-2 Conc. Beam 8"x16" (2) #5 Bars Top and Bott. w/ #3 Hoops at 12" O.C. Max. Cast in Place B-3 Wood (3) Ply 2x10 SYP N/A B-4 Precast Lintel 8F16 2T/2B (2) #5 Bars Horiz. Top and Bottom CONTRACTOR MAY USE B-2 IN LIEU OF PRECAST LINTELS IF PREFERRED FOR CONSISTENCY. Connector Schedule Connector Type Connectors Uplift Needed Uplift Provided VGT (1) 5/8"x12 Anchor Embed. & (16) 1/4"x3" SDS Screws 4,800 Ibs 4,940 Ibs HETA 16 (9) 10d x 1.5' 1,700 Ibs �1:810 Ibs HTSM 20 (10) 10d x 1.5", (4) 1/4" x 2 1/4" 1000 Ibs 1175 Ibs Comments n or Equal n or Equal n or Equal Project Number: 18AO95 W o 0 N n 0 h o a N � � c O 'N U s 0 0 N Q Q N 2 2 0 JC4 Z]— 00 w LU H o V) N � N W � a ca m Q m o Z W V O C W ) to i 0 Cr COL 3:12-17 Ln d- J Z m W O ~ � " I W N rV Q El cn Z 0-) J LL T (D N c°=o ff)ff L9 LL • 2 Yk W Q M W Q> W N Q W U M n cc - Z cc n 0 Lr Q_ U 0 j Z) Z ♦-- Ln N u1 Ln %����,+ 833N�i -Z' °2 a N ° Ua0 o ¢ Oqqo i ZoJZ h�o� go0 W U Z W d Lo Li Q In Z F 0 Q Q Q F- W 0 W W lY I Roof Framing Plan 53. 1 REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY 4 �� 00 0) t M Z O U W U 0 J 1- to J LL W U W a LL LL I TDW Floor _ loor 0" — — — — — — Founda ' n -1' - 3" I I I I 1/4"= 1'-0"I Project Number: 18A095 d e c c 0 `u m 0 6 z 00 w w H o L N K F N I W 1 { i } J W m Q co 0 Q In Z ?� W � W Ln Q W Ln V o c COL 3:12-17 Ln J Z m W O ; I ~LD Q W D 01 —� N Q Ln Z (n 0 —J - N -J LL L7 m co Uto LL ■ Z W QLLJ M J WW U ZE m = j z CC O 7 1 Z � Ln N L dg 1 H°Z N N 0 O° C iZ J Z 5 t~/l�O°0 1 0 `0 `o N O C M m E F— a° Z W z Q U LLJ `s 12 U �' o W N Q ZC ® W LO Q W Z v � J Q W v _ C7 F- O� Z ° W -� v � � o — Ul W Ln 0 6 � � o Lf l J h LL a c W N U L W a p a a N r.' o Roof Framing Sections S3.2 a REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY 5 of 6 N R(' Pn rl i Overbuilt 3/4" = 1'-0" ASPHALT SHINGLE ROOF OVER PEEL'N STICK UNDERLAYMENT OVER SHEATHING PER ROOF FASTENING SCHEDULE P.E. TRUSSES AT 24" O.C. MAX. W/ CONNECTORS PER ROOF PLAN AND SCHEDULE BEAM PER SCHEDULE AND MATCH EXISTING SOFFIT 2'-0" #5 DOWELS W/ 90 DEGREE ACI HOOK AT TOP BEAM PER PLAN/SCHEDULE OVER OPENINGS 8"x8"x16 MASONRY IN STACKED BOND, W/ (4) VERT. BARS PER COLUMN #5 DOWELS W/ 90 DEGREE ACI HOOK - z_ iD N SLOPE GRADE AWAY FROM FOUNDATION, COMPACT 24" OUTSIDE OF BLDG MIN. - SLOPE TOP TO DRAIN - 3/4" = F-0" 12 6 TYP. SLOPE 2x4 RIDGE BEAM USE MST16 ON ALL TRUSSES OVER 6-0" SPAN STRUCTURAL SHEATHING PER COMPONENTS AND CLADDING SCHEDULE P.E. TRUSS OVERFRAMING AT 24" O.C. MAX. TOP CHORD OF PRIMARY P.E. TRUSS BLOCK AS NEEDED FOR STRAPPING 01. TRUSS OVERFRAMING AT 24" O.0 MAX. STRUCTURAL SHEATHING PER COMPONENTS AND CLADDING SCHEDULE MTS 12 STRAP AT 4' O.C. TO BLOCKING OR TRUSS TOP CHORDS W/(4) 10d x 1-1/2" NAILS TYPICAL WHEN NEEDED, USE 2x4 BLOCKING BETWEEN TRUSS TOP CHORDS W/ (2) 12d END NAILS AT EACH END TRUSS TOP CHORD ATTIC OPTIONAL INSULATION, NOT REQUIRED STUCCO CEILING ON TRUSSES PER GENERAL NOTES, TEXTURE PER OWNER SLOPE TOP TO DRAIN #5 HOOP ATTOP AND MIDDLE OF COLUMNS, TYP. 1/2" CEMENTITIOUS FINISH, TEXTURE TO MATCH, PRIME AND PAINT TWO COATS EXT PAINT PER OWNER CLEAN -OUT AT EACH FILLED CELL FOR INSPECTION, EITHER SIDE OF WALL �4" THICK 3000 PSI CONC. SLAB W/ 6x6- W1.4xW1.4 OR 2.1 LBS/CUYD FIBERMESH 10 MIL VISQUEEN VAPOR ;BARRIER OVER TERMITE - TREATED, WELL -COMPACTED FILL REINFORCED CONC. FOOTER PER PLAN/SCHEDULE MISSED STRAP DOES NOT LINE UP WITH TRUS a .. a- A ° •>d ADD NEW CONNECTOR IN - LIEU OF MISSED STRAP WOOD TRUSS IF MISSED CONNECTOR IS HETA 20, CONTRACTOR SHALL USE (2) HTSM20 STRAPS W/ (4)'/4' X 2z/4" TITENS & (10)10dx1.5" IF MISSED CONNECTOR IS (2) HETA 20s, CONTRACTOR SHALL USE FGTR OR VGT PER MANUFACTURER REQUIREMENTS. -�2 Missed Strap Detail #5 BAR HORIZ. IN TOP NEW BEAM COURSE 1' - 6" #5 BAR HORIZ. IN BOTT. OF PRECAST LINTEL Beam Intersection Detail S4:T 3/4" = 1'-0" - 24" LONG #5 BAR D&E INTO (E) FILLED CELL W/ 6" EMBED. AT BOND BEAM EXIST. MASONRY COLUMN/WALL NOTCH BOTTOM 4" FOR BEARING 4" THICK, 4000 PSI CONC. W/ 6x6 - NEW EXISTING W1.4xW1.4 WWF OR FIBERMESH OVER 6 MIL. VAPOR BARRIER OVER 12" #4 DOWEL BAR EPDXIED TREATED, WELL COMPACTED FILL 6" INTO EXISTING AT 16" O.C. MAX. & 12" FROM EDGES 6"x6" THICKENED EDGE EXISTING CONCRETE SLAB AT PERIMETER NOTE: WWF OR FIBERMESH IS NOT NEEDED FOR REPAIRS UNDER 30"IN WIDTH. SEE PLAN F = FILLED WITH GROUT U = UNFILLED QUANTITY OF #5 FIELD ADDED REBAR AT BOTTOM OF LINTEL 8F16-18/1T NOMINAL WIDTH QUANTITY OF #5 FIELD ADDED REBAR AT TOP OF LINTEL NOMINAL HEIGHT 15 s/s' ACTUAL 16" NOMINAL HEIGHT s/ 8" NOMINAL WIDTH PROVIDE ADDITIONAL #5 BARS THICKEN FOOTING A MIN. OF 12" BELOW PIPE MIN. masoM 3/4" = 1'-0" FF #5 FIELD ADDED REBAR AT TOP PF COMPOSITE U - LINTEL MIN. (1) REQD 1-1/2" CLEAR, TYP. FIELD PLACED CMU SOLID GROUT, TOP TO BOT. #5 FIELD ADDED REBAR AT BOTTOM OF U-LINTEL CAVITY PRE -CAST REINFORCING PER MANUFACTURER Project Number: 18AO95 N o c a � � o 0 c o 5 '^ U C L N N 0 a `o a d 2 0 Z � w w H o in cV � d � r UJ r4 a Y on LLI QcoLU p w w w V) oaC COL 3:12-17 V* z Z °0 OU Tiw_- O n■� Iwd V J tV Q Z m J LL rn YJ 13 m U ■ Z U w Q M J W Q >wc-IQ W U OC m n L Q IR ^ H r 0LU Z F- Ln N Ln Ln i� Q Q Z W 0 W Section and Details S4.1 7 Footing Penetration Detail REVIEWED FOR 3/4" = I'_0" - _ _. - - CODE COMPLIANCE ST. LUCIE COUNTY 6 OF 6 ' I L VERIFY TYP. DET. ON IMS VERIFY ALL DIMENSIONS & MATCH EXISTING CONDITIONS AS TRUSS PLANS ARE BASED FROM ORIGINAL PLANS VERIFY HEEL HEIGHT, OVERHANG CONDITION, OVERHANG LENGTH & PITCH OF TRUSSES MATCH EXISTING CONDITIONS TRUSSES ARE FLAT @ BRG. VERIFY THERE IS NO INTERFERENCE W/ NEW TRUSS SPACING AND EXISITING TRUSSES HATCH LEGEND 8' 0" BRG. F1 *NOTE: ALL TRUSS TO WALL AND/UR -1 RUSS TO LEDGER CONNECTIONS BY BUILDER a (UNLESS NOTED OTHERWISE) $ a° C u m m E dac'e ° c 3 = E 'r w E * NOTE: ALL CEILING DROPS BELOW BEAM ARE BY BUILDER (UNLESS NOTED OTHERWISE) o o m °° g d / m * NOTE: THIS TRUSS PLACEMENT DIAGRAM IS TO D a$ iu y SHOW TRUSS I.D. AND TRUSS LOCATION ONLY. THE o T9 E rn BUILDING DESIGNER ISREPSONSIBLE FOR THE a « ` o °E 2 -OTC STRUCTURAL STABILITY OF THE ENTIRE y d 5 2 a -- E a o o ` -s STRUCTURE.REFER TO THE INDIVIDUAL TRUSS o $ o � 2 b T ENGINEERING DRAWINGS FOR GRAVITYAND UPLIFT d Q 1� 2 y a o > (/1 8 QL C.�N A — FOR BRACING & ERECTION DETAILS v g 8 9 aa� w C = _OF REFER TO BCSI-03 AND/OR ENGINEER a RECORD " N N N N E a �4v. °a o�>. d2mma.o.�,=m CnOsw 2 o. REPRESENTS THE LEFT SIDE ,...o_ "d o z t� 3 E o `& OF EACH TRUSS DRAWING E .S f° E o G y y G C M 13 ( NOTE: REFER TO USP CONNECTOR 8 ° e o ; m a C CATALOG FOR INSTALLATION DETAILS °' °' C _ " o m A JUS24 H THD46 Q - - - a a "'r E E " m ic; B JUS26 J MSH422 R--- 2 2 n £vaw�°i..a.v"i C THD26 K MUS26 S--- U o a� 5� ' m2 p THD28 L HJC26 T--- N y E a y a d ° =O'O a c °'� d c E- w 0 m o E.9.0 E THD26-2 M--- U--- F THD28-2 N - - U - - _ "'E'' Lm r m y O C N C y y 'O C7 JUS46 P --- I X --- ; 2D2Em ccaw •-rm� yt46 HBB HANGER BY BUILDER BBB BEAM BY 8 8 c to III nF=P ° m c" a m° a Q a a Z LSTA12 @TC & BC * NOTE: LSTA STRAP o a,a m� INDICATED TO BE USED IN m p o.2 9 o Zt LSTA12 @TC w N W CONCORDANCE WITH � 1 Zb LSTA12 @ BC CORNERSET DETAIL 0 8 :5 m LOADING ROOF FLOOR WIND 2 N m o C +� M '.-I O LOAD 0 LIVE 20 ASCE 7-10 'y''ro ° = � c � m o'N LOAD 0O H U DEAD 17 ' 16t) C �mEmEmra°o2 -c o 5; a LOADma a r,° ma�a�rnK LIVE 0 Residential - CAT II a � a _ C. a 0 LOAD " N m U DEAD 10 Closed a E 5 N w` c .__ Z rt; o TOTAL 47 - FBC 2017 RES CCCy777 12 C O LOAD cO w T c c r c" o N :o �_ °y M. y ? DURATION 1.25 - TPI 2014 O ,r E � ° 2 WO 00 E E DATE BY REMARKS ° : � 2 y 2 -9 3�3 z E° m o REVISE DIM_.O 1 6/6/19 RJEEo"NtNw t W O O O° N N 2 6/10/19 RJ �aE2�m O 6) S 3 6/11/19 RJ REWSED PLANE SPRINGING d j y a N y $'�='y6'0a,w FROM 7XS. BEAM o w t c8 ii c m Y c o ° d ayoFia2 oy 'N C y O � O Q O Opp v Gp] f0 O' � y y - --/--/---- u p a c e E o �. o.� c .._ N O m 2 ° z 'H m to It is understood that above APPROVED � O " y o $ $ conditions have been reviewed & H .9 E era are acceptable for the fabrication APPROVED AS .`�aciQEla-- g E at trusses, elevations, pitches, NOTED N o w 3 E= s E overhangs, fascias,ceiling ❑ REVISE AND 0 ma ' ° ° E elevations/pitches, bearing RESUBMIT cdomm€�.c ; E o H E o E 0 conditions &all detail pertaining ❑REJECTED r2 m u F-° w 8- 2 a to this truss placement plan. No v', , = y w o - a ° ;, _ back charges will be accepted a 9 E a m � a without previous written approval DATE a ° N from an A-1 Roof Trusses v a = g 8 N 8° s ._ representative. REVIEWED _° 0 N= y== o 0 0 2 Q a 0 Q o o a s m o ° 0 PLAN ARCH: /--/---- STRUCIBY--/--/---- 0 a Of cc C6 DATE ooahc3m�Uw... CUSTOMER LARRY NEESE' wyN C O N-0« y9 IJ 4, D y 8 JOB STALHUTADDlTION D m NAME E a 3 z E8mho LD Ln m ._ O .y d y W 8 N Oc a. OPTION(S) " °'gyp ° ao�,cc-rnvd E 'j F a g f0 m LLl `o m COMMNTY A C O Off'.. �❑ N O p ` a, t 0 3§2 8' E L-MY / LOT # c c O"° •O Edp O N C N d y a L y = 8 E o o F o o CITY Fort Pierce IV D uq 3 r (D L r m n0 N O rp C Z} o M T N r:3 COUNTY SAINT LUCIE a t o2'290°?F-Cm FmF BLDG BLDG o ° ; 0 " 9 — o TYPE # M c c o l d " r SCANNED y co r n o 3> a JOB 75828 MASTER St. Lucie County g y F= e a Q n O C 2 m. c c o „ 8 ❑. N..3 c c c N DRAWN SCALE w � 2 � E «4- iu DATE 5/9/19 0 o ' 9 RJ NTS Z0 mm�O WG)a°au°io i y h o m m E c MTRUSSE', v EO t o o m 5 �2 A FLORIDA CORPORATION U)�;$ a o ac M a o Ph 772-409-1010 / Fax 772-409-1015 — y ° ` 2 E " a 5' m c f0 O 0 'o http://www.a1truss.com y g N U