Loading...
HomeMy WebLinkAboutPOOL LAYOUT - DETAILS30 ft. 2 in. 11 2HP WATERFALL PUMP AND (1) 2HP PUMP FOR JETS Jandy Pro Series VS FloPro Series Pump VS-FHP2.0 Performance Curves Il-` C,0e t 3 �. ``b D 4j f I_ 2) #5 EBAR 4" 18' / 811 NO SCALE ?PEALED FASTENERS OR ATTI T ,pR NY s If1EiHERESIMUTYOtIreACTO�R Ht 8 ft. 3 in. 8 HYDRO JETS BUILT INTO WALL C CHILD SAFETY BARRIER O CD FENCE NO CLOSER THAN 20" FROM WATERLINE N EXACT LOCATION OF DECO DRAIN TO BE DETERMINED IN FIELD DECK WITH OVERPOUR �... COPING COLOR \ k 4 ft. ' LED 4' DEEP 3.5' DEEP TILED BENCH VAC TILED STEP EDGE EDGES � 11 SKIMMER Im - y .61, 40 _ __... _ .._- ------------------------------ IT SAFETY BARRIER PER FRC R4501.17.1- _62, I R4501.17.3 & ASTM5034-95, ASTM D3787- 89, ASTM 653-96 FOOTER DETAIL (1) #5 REBAR OR (2) # 3 REBAR 8., O NO SCALE 100 43 90 39 60 35 a 30 s • 60 26 50 ?? i 40 17 s25 5 30 13 d 20 9 10 4 0 0 0 0 20 W ao 6o W TO 60 90 w o%$oRdw Rate Gallons Per M 5LS 1 11 1 1 180 1T0 180 1W 200 *LOCATION OF GFI VERIFY RECEPTACLE EXACT EQUIPMENT LOCATION IN TO BE DETERMINED IN PAD FIELD WITH FIELD PER NEC 680 PER FBC SUPERVISOR /� R4501.22 30" MIN. CLEARANCE • 4� • 4� • 4� • / I IN FRONT =11IIIIIIIIIIIII12T OF SUBPANEL • POOL BARRIER PER FRC R4501.17.1- EXISTING PATIO, R4501.17.3 AND ANSUNSPI-5-1995 REMOVE THESE PLANS AND ALL PROPOSED WORK I FLAGSTONE, RRE EQUIRE BYFIELCT TO NYSPECTO STH FLOAT, TEXTURE, IONS MAY REQUIRED BY FIELD INSPECTORS THAT 0" Ot BE NECESSARY IN ORDER TO CO?�I C:'PLY WITH ALL APPLICABLE CODES. AND FLOCRETE TOI MATCH POOL DECK CERTIFICATE OF COMPLIANCE THE FOLLOWING PRODUCTS HAVE BEEN TESTED TO ANSIlAPSP-16 2011 PER SECTION 1404 OF THE VIRGINIA GRAEME BAKER POOL AND SAFETY ACT (VGB-2008) AND SAFETY REGULATIONS SET FORTH BY THE CPSC. THESE PRODUCTS ARE MANUFACTURED BY CUSTOM MOLDED PRODUCTS, INC, IN SHANGHAI, CHINA AND CERTIFIED BY UNDERWRITERS LABORATORIES, INC., AT 2929 E IMPERIAL HIGHWAY, SUITE 100, BREA, CA, 92821 (PH: 714-223-3000) OR IAPMO R&T LAB AT 6001 E. PHILADELPHIA STREET, ONTARIO, CA, 91161 (PH: 909-472-4100). A COPY OF THE TEST RESULTS MAY BE FOUND AT W W W.UL.COM OR W W W.PLD.IAPMO.ORG FILE CO P`CHNICALGI FILE T 1f01, to PWMBIN6 POR13 HOW IIOW RATE MR -= i' OI II '.. UVM ')'I. M•� J�' INIj� jB(I f!� l�It41M l' OR IM 1lPM tENTNTkN iM PM 176I6bPM CW MiEVEWi jPMMY201faOi 6f FF5i MOLIC01 I lA0' IRV NF ke IPa. 10'1 Mua*n�'erNmeedvmoN 40 20 I i ° RMV M iM 240 RD RIM) DATE OF MANUFACTURF'. CUSTOM MOLDED PRODUCTS 136 HERRING ROAD, NEWNAN, GA 30265 WWW.C--M-P.COM ST. LUCIE COUNTY BUILDING DIV REVIEWED FOR COMPLIANCE REVIE EM19-1 DATE PLANS AND PE MIT MUST BE KEPT OV JOB SITE OR NO INSPECTION(S) WILL B ADE 18" MIN. ( ENTIRE PERIMETER) PAVER DECK OR CONCRETE DECK 4C W.L. SOIL #8 SOLID COPPERS 'ND WIRE W1 APPR. CLAMPS (ONE ON EACH SIDE OF POOL TOTAL) 8 GAUGE SOLID COPPER WIRE - EQUIPOTE_NTIAL BONDING. GRID DETAIL PER N.E.C. 2014 SEC. 680.26 MINIMUM IS- (MAXIMUM 24••) FROM EDGE OF POOL AR( (WHERE ADOPTED) ENTIRE POOL PERIMETER BURIED 4" TO 6" DEEP M_ISC._NOTE$ 1. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2X6 CAPTILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY 2. HAND HOLD TO BE INSTALLED AT ARE WHERE DECK RAISED-6" ABOVE POOL moo, 48" WA MAX WATER DEPTH p10•• MIN. iLL - 12" MAX. " N.T.S. WHEN PROVIDED SHALL BE AT 20" MAX. BELOW THE WATERLINE 20"I aX. N.T.S. POOL DETAIL APPROVED MAIN DRAIN FRAMES AND GRATES PER V.G.B. ASME/ ANSI 112.19.8-2007 �I ,t o:1p i:• oti=Nkt OR AT; AC,HAAC�f'fS ARL `f7H[ RESPONSIBILITY OF THE CONTRACTOR OR HEIG FID ELITE GAS SCREEN BY PIONEER I APPROVED WITH THE 2017 FLORIDA BUILDING CODE 6T" EDITION FOP IESIDENTIAL AND THE ANSI/APSP-7 2� FOR SUCTION ENTRAPMENT AVOIDANCE 0 0 0 ° 2.5" RETURN TO HYDROS ° UNBLOCKAB_LE CHANNEL DRAIN 0 • ° ° 0 2.5" LINE TO FILTRATION 3" LINE TO HYDRO JET P MP PUMP, MAX 181 GPM MAX 117 GPM 8 FPS MAX 2" RETURN TO FIRST TEE CONCEALED FASTENERS OR ATTACHMENTS OOWRAARE THE ECTORORIRECOR UTY OF D #8 GROUND WIRE HANDRAIL BONDING DETAIL WHERE APPLICABLE STEPS PER NATIONAL ELECTRICAL CODE 1. TREAD IS MIN. OF 10" WIDE. 2. RISER NOT GREATER THAN 12" EXCEPT IF MORE THAN 13) TREADS ARE USED. 3. ALL STEPS TO BE SOLID GUNITE 3000 PSI. FILE COPY FILE COPY POOLBOND P_B-2008 DECK WATER NO WIRE GRID L__O_ CATION_OF WATER BOND \TIC QUIPMENT LAYOUT N.T.S. EQ. LAYOUT o! w 14 LL (NO SCALE) GENERAL NOTES: i � A RISER WALL DETAIL (NO SCALE) TILED EXTERIOR FRONT AND BACK OYERPOUR SHEER DESCENT COPING OOL DECK • APPROVED WITH THE 2017 FLORIDA BUILDING CODE 6T" EDITION FOR RESIDENTIAL CUD pp, 1. SWIMMING POOL CONSTRUCTION TO COMPLY W/ FLA. BLDG. CODE AND WITH ALL LOCAL ORDINANCES AND �R'\ ZONING ��/% �'*J 2. SWIMMING POOL TO BEAR ON ROCK OR UNDISTURBED SAND. ALL WALLS AND FLOORS SHALL BE GUNITED OR LNG POOL O POURED IN -PLACE C(NCRETE W/ MINIMUM 3,000 P.S.I. CONCRETE (@ 28 DAYS) COMPRESSIVE STRENGTH. 3 2 3. ENGINEER SHALL BE NOTIFIED IF SOIL BEARING LESS THAN 2500 P.S.F., OR MUCK, SILT OR LOOSE, SOFT SOIL IS ' FOUND. A SOIL BEARNG CAPACITY OF 2,500 P.S.F. HAS BEEN USED IN THE DESIGN. LEGEND 4. REINFORCING BAM SHALL BE NEW BILLET, GRADE 40. 5. ALL POOL PIPING T) BE P.V.C. SCHEDULE 40 MIN. AND BEAR THE N.S.F. APPROVAL. 6. BACK -WASH SHALL BE IN COMPLIANCE WITH LOCAL ORDINANCES. . 2" VACUUM LINE 7. DISPOSAL OF POOL WATER SHALL CONFORM TO LOCAL ORDINANCES. SURFACE GRADING SHALL CONTAIN , 2.5" POOL MAIN DRAIN WATER WITHIN PROPERTY LINES. PONDING SHALL NOT PERSIST FOR MORE THAN ONE HOUR. 2" SKIMMER LINE 8. WATER SUPPLY & DISPOSAL SHALL BE INSTALLED SO THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC , WATER SUPPLY OR WATER DISPOSAL SYSTEM. .2" POOL RETURN LINE TO FIRST TEE, 1.5" TO POOL 9. GRATE AT MAIN DETAIN SHALL HAVE A FREE AREA OF 4X THE AREA OF THE SUCTION LINE .2" SUPPLY LINE TO WATERFALLS 10. HAIR & LINT STRANERS SHALL HAVE A REMOVABLE SCREEN W/ A MINIMUM FREE AREA OF 3X THE AREA OF THE JANDY TRUE CLEAR SALT SYSTEM SUCTION LINE. 11. ELECTRICAL: INSTALL WIRING & DEVICES AS SHOWN IN "POOL DATA" HEREON. LIGHT CONNECTION TO . 2.5" RETURN LINE TO HYDRO JETS CONFORM TO NATIOML ELECTRICAL CODE- LATEST EDITION. . 3" SUCTION LINE 12. ALL METALLIC C04DUITS, PIPING SYSTEMS, REINFORCED STEEL, LIGHT FIXTURE@ & HOUSING, METAL PARTS OF LADDERS, HANDRAIU, DIVING BOARDS & SUPPORTS TO BE BONDED TOGETHER & (MOUNDED TO A COMMON A. 1.5" TO WASTE OR DISCHARGE TO GROUND GROUND. BONDING C)NDUCTOR SHALL NOT BE SMALLER THAN #8 COPPER. .2HP JANDY VARIABLE FHPM PUMP WITH W/APPR HAIR AND LINT STRAINER 13. NO OVERHEAD OPEN WIRE OVER POOL WATER. 14. CARTRIDGE FILTER SHALL HAVE A FILTRATION RATE NOT TO EXCEED 3 G.P.M. / S,F. OF FILTER AREA. NO BACK- . CARTRIDGE FILTER W/ PRESSURE GAUGE AND AIR RELIEF VALVE WASH REQUIRED. VALVES (TYPICAL) 15. CONTRACTOR SHILL VERIFY ALL DIMENSIONS AND CONDITIONS AT SITE BEFORE STARTING THE PROJECT. , INSTALL PERMA-CAST WATER BOND OR APPROVED EQUAL TIED TO PUMP CONTRACTOR SHALLVERIFY LOCATION OF ELECTRICAL SERVICE BY F.P.&L. COMPANY. ROUND W/ #8 SOLID COPPER & APPROVED LUG (MIN. 9 SQ. IN SURFACE AREA 16. SPECIAL ATTENTION SHALL BE GIVEN TO EXISTING FOUNDATION TO PREVENT UNDERMINING. XPOSED TO WATER) PER MFGR'S SPECS (FIELD VERIFY LOCATION) 2HP JANDY PHPM JET PUMP WITH W/APPR HAIR AND LINT STRAINER 6' AND FURTHER = 4°THICK WALLS W/#3 REBAR @ 12" O.C. EACH WAY X TO 6' = 6" THICK WALLS WI#3 REBAR @ 12" O.C. EACH WAY W TO 3' = 8" THICK WALLS W/#3 REBAR @ 12" O.C. EACH WAY 9 ft. 6 ft. W 3 3 'v bD 3 ft. / � W y 0 s 4. 0 W J 0 � 2 I Q EXCAVATION INTO THE ANGLE OF REPOSE IS ALLOWABLE PROVIDED: * SHORING IS INSTALLED AT EXCAVATION AND SHORING SHOULD BE SUFFICIENT TO SECURE SOILS FROM EROSION OR SETTLEMENT * NO UNDERMINING OCCURS OR ENGINEER APPROVED IF ANY DOES * COMPACTION TEST OF THE BACKFILLED MARTIAL ARE PROVIDEDAT C.O. OF THE SWIMMING POOL POOL PATIO�i WATER LEVEL FROM 60 1" LIGHT SPU PELY CONDUIT UNDERWATE UNDERWATER LIGHT NO LIGHT DETAIL NICHE (NO SCALE) APPROVED GROUND CLAMP CONTINUOUS BOND WIRE COMMON TO POOL STEEL, POOL FINISH RAILS & EQUIPMENT ELECTRICAL DIAGRAM AND ELECTRICAL DIAGRAM N.T.S. r-' OUTLET PER 2014 NEC HEATER (GAS) JANDY TRUE 3-#12 THHN CU WITHIN'/2" CLEAR SALT 2HP JANDY PHPM JET PUMP W/BUILT-IN CONDUIT SYSTEM OVERLOAD SWITCH W/3-#10 THHN CU -.-- POOL PANEL W/ 60 AMP WITHIN IA" MIN. CONDUIT BRKR & (2)-#6 & (2) #10 GND / THHN CU IN 1" RPVC CONDUIT }yl/ MANUAL I / SWITCHTOR MOTOR WITH BUILT-IN UIILT- NSPEED JOVERLOADANDY P S.P.S.T. TOGGLE SWITCH (1) POOL LIGHT \ (CFI NOT REQUIRED) y JUNCTION E WITCH W/3-#10 THHN CU WITHIN'f1" MIN. CONDUIT (GFCI PROTECTED) CLOCK ;ONNECT I PUMP BONDED 12 VOLT TRANSFORMER BACK TO POOL . ALL ELECTRICAL TO COMPLY WITH 2O14 NATIONAL ELECTRIC CODE. ELECTRICAL CONTRACTOR TO VERIFY DEQUATE CAPACITY AT POINT OF CONNECTION .3412 THHN CU WITHIN'/2" MIN. CONDUIT FOR POOL LIGHT(S) .GROUND ALL BOXES, LIGHTS, MOTORS, ETC. w/#8 SOLID, BARE COPPER. . PROVIDE W.P.G.F.1. OUTLET 10'MIN. -20' MAX. FROM WATER'S EDGE. . ALL POOL PUMPS TO BE GFCI PROTECTED PER NEC 680.22(B) RECORD CONCEA �.ETDE� FASTENERS j CONCRETE DECK 1/4"PER FT. SLOPE NQ_7@; REMOVE GRATE 8 WELL POINT PLUG FROM MAIN OVERPOUR BEND INTO D CK @ 48" OZ'MAX--► DRAIN &ATTACH AUX. PUMP (OR GAP T WHERE d, LINE WHEN EMPMNG POOL APPLICABLE ATERLIN • 4" SLAB TILE 2500 FIRE GRATE SHALL BE SECURED IN INTERIO 4 /2" TYP. TYPICAL WALL PLACE SO FINISH WALL SECTION & THAT TOOLS � WELL POINT ARE REQUIRED (NO SCALE) FOR REMOVAL STEEL-TEX FORM 6., NP• R KRAFT WALL 1-14 FLOOR #3 @ 72" O.C.B.W. NOTE: FOR DEPTHS THREADE REATER THAN 6' ADD I - PLUG PLUG COVE BAR @ 6" O.C. TO PUMP 0 GRAVEL BED SPECIFICATIONS MAX. WIDTH 13' MAX. LENGTH 17' MIN. DEPTH 3.5' MAX. DEPTH 4' SHAPE GUST ELEVATION T.B.D FILL FROM EXCAVATION HAUL TILE INTERIOR FINISH GEM FILTER CS200 PUMP MAKE PER FBC 4501.20 JANDY 2HP VS FLOPRO PUMP HP: POOL 2HP VS FLO PRO JETS PUMP: 2HP PHPM FILTRATION PUMP COMPLIANT WITH ANSUAPSP/ICC-15 2011 LIGHTS POOL 1 CLR LED SPA NA _ TRNFORM: POOL 300 WATT SPA NA MAIN DRAIN: POOL 2 SPA NA _ SKIMMER S1) TIMER INCL RETURNS: POOL 2 SPA NA JETS: POOL 8 SPA NA VALVED VAC LINE INCL FILL LINE NA DISCHARGE LINE TO GROUND CHLORINATOR JANDY TRU CLEAR SALT HANDRAIL NA LADDER NA DIVING BOARD NA SLIDE NA HEATER JANDY 400K BTU PROPANE HEATER VACUUM HEAD INCL POLE INCL VACUUM HOSE INCL BRUSH INCL LEAF SKIMMER INCL TEST KIT INCL TREE/STUMP REMOVAL NA REMOVE EXISITING CONCRETE NA SCREEN BY PIONEER SCREEN ELECTRICAL INCL POOL PATIO CONCRETE FLOCRETE EXISTING PATIO FLOAT AND FLOCRETE DECK DRAIN INC GALLON CAPACITY -POOL 4,151 GAL. GALLON CAPACITY -SPA NA TURN -OVER RATE 6 hrs TERMITE TREAT INC BARRIER INC MAX. WATER VELOCITY .6 ft./s FROM TRUNK LINES TO 8 ft./$ SUCTION LINES 10fp_s MAX RETU_R_N. _LINE SKIMMER _MIN. _FLOW 25 GPM SURFACE AREA OF POOL - 142 $Q. FT 48 LN FT JOB NAME: PATRICK ADDRESS: 7921 PLANTATION LAKES DR, PORT ST LUCIE, FL, 34986 PERMIT NO.: DATE DRAWN: DECEMBER 17T" 2018 DRAWN BY: JASON BARAN DESIGNER APPROVAL: CUSTOMER APPROVAL: SCALE: 1/4" = 1' RAY REINHARD PE # 47041 1010 Easter Lilly Lane Unit 203 � Vero Beach, FL 32963 CONCRETE OLS, INC. FILE COPY DECK''+1 7 ROW OF WATERLINE TILE R 3 5, WATERLINE WALLS #3 STEEL @ 12" OIC E.W. SHALL FLOOR SLOPE �'" st_nPL FLOOR SLOPES SHALL RE I� REASONABLY UNIFORM AND C7RFA'i ER COMPLY WITH ARTICLES 5.6.1 TFIAN IT* THHU 5 6 3 CYCOLAC M14' 3 NOT THE SLOPE OF THE FLOOR FROM THE SHALLOW END WALL TOWARDS THE DEEP AREA SHALL NOT EXCEED 1 FOOT IN 7 FOOT 17, TY�L SECTION THRU POOL (NO SCALE) 7-1 RFCArVED BAN o 3 zsls PeTmlttlne /a St. Lu`le e°unry®nrLye