Loading...
HomeMy WebLinkAboutCERTIFICATE - DESIGN LOAD COMPLIANCEcoutvey �'` Project Project Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Permit#: Occupancy Type: Construction INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single ormulti-family) SCANNED o Residential Addition BY o Any accessory structure requiring a building permit St. Lucie County o Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Building Code Fifth Edition with 20 NSA Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV Exposure Category: _B X C _D 4. Design Wind Velocity 160 n mph X ASD _LRFD End Zone Width: 6 ft S. Mean Roof Height / D ft Roof Pitch: 6 :12 Parapet: NSA ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, dearly label on all plan openings1 .f Zp.0 4-20.0-t-zo.0 4-3Y,77- t3y.';17 4-ZY,7 Zone 1: — V. A Zone 2: —5Y;3 Zone 3: — S7v J- Zone 4: 6 Zone 5: ^Y6 •S"Garage: — 2 s 7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: NIA PSF Dock: NSA PSF Deck: N/A PSF Stairs: N/A PSF Fence: NIA PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? Yes XNotApplicable Explain Why Not: Apim-'r 04$70 ::, 4-y 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified:' 572-0 .. , Print Name Cert # & Co. Cert Auth. Nc/ffCG� �Na/�t//-�l�%Llit/l s' re, -Date, and Sea[ ^ s� _dl63_`1 (5w,* 6 fte754. r•� �9�o Company Name&Address Revised 07/25/2014