HomeMy WebLinkAboutENERGY EFFICIENCY CODEFILE COPY
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
rw
Project Name: MW-60
�191
Builder Name: GHO HOMES Nry
St i' �®
t: 2654 CONIFER PR
Permit Office: ST. LUCIE�BxLDG DPTMNT
Permit Number;
�4Cie
ItytreBState, Zip: FORT PIERCE , , 34951
-Design
�' Z ��
Z COUn
Owner:
Jurisdiction:
'III
Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1830.1 sgft.)
Insulation Area
2. Single family -or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.0 1632.60 ft2
b. Frame - Wood, Adjacent
R=11.0 197.56112
-3.'`Number� of units, if multiple family 1
c. N/A
R= ft2
4. Numberl of Bedrooms 2
d. N/A
R= ft2
10. Ceiling Types (1832.0 sgft.)
Insulation Area
5. Is this aIworst case? No
a. Under Attic (Vented)
R=30.0 1832.00 ft2
6. Conditiohed floor area above grade (ft2) 1832
b. N/A
R= ft2
-- Conditiohhed floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R W
7. Windows(263.7 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main
6 629
a. U-Factor: Dbl, U=0.62 263.67 ft'
SHGC: SHGC=0.26
b:- U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
130 SHGC:
a. Central Unit
36.0 SEER:16.00
cr•U-Factor: N/A ft2
`:. SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
24.8 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 0.000 ft.
Area Weighted Average SHGC: 0.260
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1832.0 sgft.) Insulation Area
EF: 0.900
a. Slab -On -Grade Edge Insulation R=0.0 1832.00 ft2
b. Conservation features
b. N/A R= ft2
None
�. c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.144 Total Proposed Modified Loads: 57.55
PASS
Total Baseline Loads: 61.28
I hereby certi that the plans and specifications covered by
Review of the plans and
SHE STgp�
this calculation re in c mpliance ith the Florida Energy
specifications covered by this
04
Coale,
calculation indicates compliance
with the Florida Energy Code.
F nui :::"'%. ,-;a;`,'•1`,��y=��n �O
PREPARED B "
Before construction is completed
C
DATE:
this building will be Inspected for
compliance with Section 553.908
I hereby certify that this bu'toing, as design d, is in compliance
Florida Statutes.
with the Florida En y/Ced .
COp 1.V8'(8�
„OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed In accordance with R403.3.2.1.
t Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (11402. .
I
RECEDE
I JAN 2 2 2019
1 1/17/2019 10:52 AM
EnergyGauge® USA Section R405.4.1 Compliant
Page 1 f 4
ermitting Department
St. Lucie County, FL
IFOF tM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
. Owner Name:
# of Units:
,.' Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
MW-60 Bedrooms: 2
User Conditioned Area: 1832
Total Stories: 1
1 Worst Case: No
GHO HOMES Rotate Angle: 0
ST. LUCIE BLDG DPTMNT Cross Ventilation: No
Whole House Fan: No
Single-family
New (From Plans)
Address Type:
Lot #
Block/Subdivision:
PlatSook:
Street:
County:
City, State, Zip:
Street Address
2654 CONIFER DR
St. Lucie
FORT PIERCE,
FL, 34951
CLIMATE
M Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299
62 Low
BLOCKS
Number
Name
Area Volume
1
Blockt
1832 17037.6
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled Heated
'^L 1
Main
1832 17037.6 Yes 3
2
1 Yes
Yes Yes
•s j
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 166.5 ft 0
1832 ft'
----
0 0 1
ROOF
/
#
Type
Roof Gable Roof
Materials Area Area, Color
Solar
Absor.
SA Emitt
Tested
Emilt Deck Pilch
Tested Insul. (deg)
1
Hip
Concrete 2049 ft2 0 ft' Medium
0.4
N 0.9
No 0 26.6
ATTIC
a
#
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 1832 ft'
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1832 ft' 0.1
Wood
i
I�
1/17/2019 10:52 AM
EnergyGauge® USA Section R405.4.1 Compliant Software
Page 2 of 4
F:nRM R405-9017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
VUV f-bmt-
To WAII-Typ, Space
R--Value_ Ft In Ft
-I
Are,
RAInlue-Fractlon-AbsorrGradp-0 -
rc
1 N
Exterior Concrete Block - Ext Insul Main
4 43 7 9
4
406.8 112
0
0 0.3
0
_ 2 E
Exterior Concrete Block - Ext Insul Main
4 53 10 9
4
502.4 112
0
0 0.3
0
-3 S
Exterior Concrete Block - Ext Insul Main
4 19 6 9
4
182.0 ft'
0
0 0.3
0
_ 4 W
Exterior Concrete Block - Ext Insul Main
4 58 0 9
4
541.3 ft'
0
0 0.3
0
5
Garage Frame - Wood Main
11 21 2 9
4
197.6 112
0
0.25 0.3
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S Wood Main
None
.39
3
8
24 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
.:./
Wall
Overhang
V #
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
_ 1
n 1 Metal Double (Clear) Yes
0.62 0.26 N
30.0 ft'
0 ft 0 in
0 it 0 in
None
None
2
n 1 Metal Double (Clear) Yes
0.62 0.26 N
36.0 ft2
0 ft 0 in
0 ft 0 in
None
None
3
n 1 Metal Double (Clear) Yes
0.62 0.26 N
96.0 ft2
0 it 0 in
0 ft 0 in
None
None
4
e 2 Metal Double (Clear) Yes
0.62 0.26 N
12.0 ft'
0 ft 0 in
0 ft 0 in
None
None
5
e 2 Metal Double (Clear) Yes
0.62 0.26 N
7.0 ft'
0 ft 0 in
0 ft 0 in
None
None
6
e 2 Metal Double (Clear) Yes
0.62 0.26 N
21.7 11:2
0 ft 0 in
0 ft 0 in
None
None
7
s 3 Metal Double (Clear) Yes
0.62 0.26 N
26.0 ft2
0 ft 0 in
0 ft 0 in
None
None
8
w 4 Metal Double (Clear) Yes
0.62 0.26 N
20.0 ft'
0 ft 0 in
0 ft 0 In
None
None
9
W 4 Metal Double (Clear) Yes
0.62 0.26 N
15.0 ft2
0 ft 0 in
0 ft 0 in
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Well Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
584 112 584 ft'
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000295
1419.8 77.95 146.59
.224
5
HEATING SYSTEM
#
System Type Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/ None
CORI
24.82 kBlu/hr
1
sys#1
r ei
1/17/2019 10:52 AM EnergyGau'ge® USA Section R405.4.1 Compliant Software Page 3 of 4
`rcr
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype.
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
SEER: 16
36 kBlu/hr
1080 cfm
0.7
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnl
Conservation
1 Electric
None
Garage
0.9 50 gal
62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
DUCTS
Supply ---
-- Return ---
Air
CFM 25 CFM25
HVAC #
V If Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
ON
RLF
Heat Cool
1 Attic
6 629 ft'
Attic
515 fl' Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programablfre Thermostat: Y
C[feiling Fans:
Jan ebr(�,
Mar
JX� Apr
rr Junrr
May Jun Jul
rr
Aug
fr r
Sep
ct
Oct
Nov
X Nov
Dee
Dec
Venting [ Jan Feb
[X]
[
[x� [x�
[X�
[
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8 9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78 80
80
80
80
PM
80
80 78
78 78 78
78
78 78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78 78
78
78
78
PM
78
78 78
78 78 78
78
78 78
78
78
78
Heating (WD) AM
66
66 66
66 66 68
68
68 88
68
68
68
PM
68
68 68
68 68 68
68
68 68
68
66
66
NHeating (WEH) AM
66
66 66
66 66 68
66
68 68
68
68
68
PM
68
68 68
68 68 68
68
68 68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ft'
0 ft
0.3
Main
Name:
Rating Compant:
Signature:
Date:
,' 1/17/2019 10:52 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family) 3. 1
4. Number of bedrooms
4. 2
5. Is this a worst case? (yes/no)
5.
No
6. Conditioned floor area (sq. ft.)
6.
1832
r 7. Windows, type and area
- a) U-factor:(weighted average)
7a.
0.620
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.260
c) Area
7c.
263.7
8. Skylights
a) U-factor:(weighted average)
8a.
NA
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
ga.
0.0
b) Wood, raised (R-value)
9b.
c) Concrete, raised (R-value)
9c.
10, Wall type and Insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
10A1.
2. Masonry (Insulation R-value)
10A2.
4.0
B. Adjacent:
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10B2.
13. Cooling system:
Capacity 36.0
a) Split system
SEER 16.0
b) Single package
SEER
c) Ground/water source
SEER/COP
d) Room unit/PTAC
EER
e) Other
14. Heating system: Capacity 24.8
a) Split system heat pump HSPF
b) Single package heat pump HSPF
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
9 Other
15. Water heating system
a) Electric resistance EF 0.90
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
f) Heat recovery unit HeatRec%
g) Other
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level a) Ceiling fans
a) Under attic 11a. 30.0 b) Cross ventilation No
b) Single assembly 11b. c) Whole house fan No
c) Knee walls/skylight walls 11c. d) Multizone cooling credit
d) Radiant barrier installed 11d. No e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has coplied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be Pstalled (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completef based on installed code compliant features.
Builder
Date: I Ian
Address of New Home: 2654 CONIFERDR City/FL Zip: FORT PIERCE, FL 34951
1/17/2019 10:52:11 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1