Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFILE COPY FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method rw Project Name: MW-60 �191 Builder Name: GHO HOMES Nry St i' �® t: 2654 CONIFER PR Permit Office: ST. LUCIE�BxLDG DPTMNT Permit Number; �4Cie ItytreBState, Zip: FORT PIERCE , , 34951 -Design �' Z �� Z COUn Owner: Jurisdiction: 'III Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1830.1 sgft.) Insulation Area 2. Single family -or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.0 1632.60 ft2 b. Frame - Wood, Adjacent R=11.0 197.56112 -3.'`Number� of units, if multiple family 1 c. N/A R= ft2 4. Numberl of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types (1832.0 sgft.) Insulation Area 5. Is this aIworst case? No a. Under Attic (Vented) R=30.0 1832.00 ft2 6. Conditiohed floor area above grade (ft2) 1832 b. N/A R= ft2 -- Conditiohhed floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R W 7. Windows(263.7 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 629 a. U-Factor: Dbl, U=0.62 263.67 ft' SHGC: SHGC=0.26 b:- U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency 130 SHGC: a. Central Unit 36.0 SEER:16.00 cr•U-Factor: N/A ft2 `:. SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 24.8 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 0.000 ft. Area Weighted Average SHGC: 0.260 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1832.0 sgft.) Insulation Area EF: 0.900 a. Slab -On -Grade Edge Insulation R=0.0 1832.00 ft2 b. Conservation features b. N/A R= ft2 None �. c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.144 Total Proposed Modified Loads: 57.55 PASS Total Baseline Loads: 61.28 I hereby certi that the plans and specifications covered by Review of the plans and SHE STgp� this calculation re in c mpliance ith the Florida Energy specifications covered by this 04 Coale, calculation indicates compliance with the Florida Energy Code. F nui :::"'%. ,-;a;`,'•1`,��y=��n �O PREPARED B " Before construction is completed C DATE: this building will be Inspected for compliance with Section 553.908 I hereby certify that this bu'toing, as design d, is in compliance Florida Statutes. with the Florida En y/Ced . COp 1.V8'(8� „OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. t Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (11402. . I RECEDE I JAN 2 2 2019 1 1/17/2019 10:52 AM EnergyGauge® USA Section R405.4.1 Compliant Page 1 f 4 ermitting Department St. Lucie County, FL IFOF tM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: . Owner Name: # of Units: ,.' Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: MW-60 Bedrooms: 2 User Conditioned Area: 1832 Total Stories: 1 1 Worst Case: No GHO HOMES Rotate Angle: 0 ST. LUCIE BLDG DPTMNT Cross Ventilation: No Whole House Fan: No Single-family New (From Plans) Address Type: Lot # Block/Subdivision: PlatSook: Street: County: City, State, Zip: Street Address 2654 CONIFER DR St. Lucie FORT PIERCE, FL, 34951 CLIMATE M Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockt 1832 17037.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated '^L 1 Main 1832 17037.6 Yes 3 2 1 Yes Yes Yes •s j FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 166.5 ft 0 1832 ft' ---- 0 0 1 ROOF / # Type Roof Gable Roof Materials Area Area, Color Solar Absor. SA Emitt Tested Emilt Deck Pilch Tested Insul. (deg) 1 Hip Concrete 2049 ft2 0 ft' Medium 0.4 N 0.9 No 0 26.6 ATTIC a # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1832 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1832 ft' 0.1 Wood i I� 1/17/2019 10:52 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4 F:nRM R405-9017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below VUV f-bmt- To WAII-Typ, Space R--Value_ Ft In Ft -I Are, RAInlue-Fractlon-AbsorrGradp-0 - rc 1 N Exterior Concrete Block - Ext Insul Main 4 43 7 9 4 406.8 112 0 0 0.3 0 _ 2 E Exterior Concrete Block - Ext Insul Main 4 53 10 9 4 502.4 112 0 0 0.3 0 -3 S Exterior Concrete Block - Ext Insul Main 4 19 6 9 4 182.0 ft' 0 0 0.3 0 _ 4 W Exterior Concrete Block - Ext Insul Main 4 58 0 9 4 541.3 ft' 0 0 0.3 0 5 Garage Frame - Wood Main 11 21 2 9 4 197.6 112 0 0.25 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Wood Main None .39 3 8 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. .:./ Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening _ 1 n 1 Metal Double (Clear) Yes 0.62 0.26 N 30.0 ft' 0 ft 0 in 0 it 0 in None None 2 n 1 Metal Double (Clear) Yes 0.62 0.26 N 36.0 ft2 0 ft 0 in 0 ft 0 in None None 3 n 1 Metal Double (Clear) Yes 0.62 0.26 N 96.0 ft2 0 it 0 in 0 ft 0 in None None 4 e 2 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft' 0 ft 0 in 0 ft 0 in None None 5 e 2 Metal Double (Clear) Yes 0.62 0.26 N 7.0 ft' 0 ft 0 in 0 ft 0 in None None 6 e 2 Metal Double (Clear) Yes 0.62 0.26 N 21.7 11:2 0 ft 0 in 0 ft 0 in None None 7 s 3 Metal Double (Clear) Yes 0.62 0.26 N 26.0 ft2 0 ft 0 in 0 ft 0 in None None 8 w 4 Metal Double (Clear) Yes 0.62 0.26 N 20.0 ft' 0 ft 0 in 0 ft 0 In None None 9 W 4 Metal Double (Clear) Yes 0.62 0.26 N 15.0 ft2 0 ft 0 in 0 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Well Perimeter Avg. Wall Height Exposed Wall Insulation 1 584 112 584 ft' 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000295 1419.8 77.95 146.59 .224 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None CORI 24.82 kBlu/hr 1 sys#1 r ei 1/17/2019 10:52 AM EnergyGau'ge® USA Section R405.4.1 Compliant Software Page 3 of 4 `rcr FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype. Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 36 kBlu/hr 1080 cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnl Conservation 1 Electric None Garage 0.9 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None DUCTS Supply --- -- Return --- Air CFM 25 CFM25 HVAC # V If Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 629 ft' Attic 515 fl' Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programablfre Thermostat: Y C[feiling Fans: Jan ebr(�, Mar JX� Apr rr Junrr May Jun Jul rr Aug fr r Sep ct Oct Nov X Nov Dee Dec Venting [ Jan Feb [X] [ [x� [x� [X� [ Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 88 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 NHeating (WEH) AM 66 66 66 66 66 68 66 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft' 0 ft 0.3 Main Name: Rating Compant: Signature: Date: ,' 1/17/2019 10:52 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 5. Is this a worst case? (yes/no) 5. No 6. Conditioned floor area (sq. ft.) 6. 1832 r 7. Windows, type and area - a) U-factor:(weighted average) 7a. 0.620 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260 c) Area 7c. 263.7 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) ga. 0.0 b) Wood, raised (R-value) 9b. c) Concrete, raised (R-value) 9c. 10, Wall type and Insulation: A. Exterior: 1. Wood frame (Insulation R-value) 10A1. 2. Masonry (Insulation R-value) 10A2. 4.0 B. Adjacent: 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10B2. 13. Cooling system: Capacity 36.0 a) Split system SEER 16.0 b) Single package SEER c) Ground/water source SEER/COP d) Room unit/PTAC EER e) Other 14. Heating system: Capacity 24.8 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE 9 Other 15. Water heating system a) Electric resistance EF 0.90 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec% g) Other 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has coplied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be Pstalled (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completef based on installed code compliant features. Builder Date: I Ian Address of New Home: 2654 CONIFERDR City/FL Zip: FORT PIERCE, FL 34951 1/17/2019 10:52:11 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1