HomeMy WebLinkAboutPLAN REVIEW RECORD1812-0502
PLEASE ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK CONTAINING THE SQUARE FOOT INFORMATION. SEE
CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE SIXTH EDTITION.
THE ENERGY CALULATIONS MUST HAVE THE PREPARERS ORIGINAL SIGNATURE PLEASE FURNISH NEW ENERGY CALULATIONS WITH ORIGINAL
SIGNATURES PER 107.1 OF THE 2017 FLORIDA BUILDING CODE
ENERGY CALCS INFORMATION BLOCK ATTHE TOP OF THE PAGE IS INCOMEPLETE BUILDERS NAME PERMIT OFFICE ARE MISSING. SEE SECTION
405.4.2 (1) OF THE 2017 FLORIDA ENERGY CODE.
SCANNED
BY
St. Lucie County
2015 INTERNATIONAL
RESIDENTIAL CODE®' Plan Review # 1812-0502
Date:1/16/19
FOR ONE- AND TWO-FAMILY DWELLINGS Valuation: $335,081.25
PLAN REVIEW RECORD Fee: $2409.21/ $17,194.21
FORT,PIERCE, FL 34951
"
"
JURISDICTION:
(City, County, Township,. etc.)
BUILDING LOCATION: 2654 CONIFER DRIVE
(Streetaddress) ,. SCANNED
BUILDINGDESCRIPTION:: 8FR BY
ucie GouMy
BY:
.REVIEWED
Numerals Indicated in parenthesis areapplicable code sections of the 2015 lntemationaM slidentialCode (IRC). The plan review accomplished as indicated
"in this record is,limitedto those`oode sections specifically Ideribfiedherein. This moored references commonly applicablecode sections with due regard for. '
the amount and type of detailed information which: [a. typically found"on construction documents for one- and two-family 6weilings and townhouses. It does-,
not referenoe all code provisions which may be applicable to specific buildings. This record is designed to be used only by those who areknowledgeabto. -
'and :capable of exerctsingmmpetentljuagment inevaivating.constmcfion documents for code complianoa. ;
CORRECTIONS LIST
No.
DESCRIPTION
Code
Section
i • • ed ISBN 97a-1-60963-611-5
Tmbernark • • III IIIIII III III IIIIIII III
IMERNATIDNAL INTERNATIONAL CODE COUNCIL,9 781609 836115
CODEICOUNCICPHONE• • 1 1
-1-
CORRECTION LIST (cont'd.)
No. DESCRIPTION Code
Section
I
-2-
NOTE: Entries to this Plan Review Record that require a field check or Inspection of the installation must be coordinated with the inspection phase (R109) of the project.
BUILDING PLANNING (Chapter 3)
DESIGN CRITERIA [Table R301.2(1)] Parapets and construction
Floor live load (Table R301.5) psf (R302.2.2, R302.2.3)
Roof live load (Table R301.6) 30 psf Two-family dwelling separation (R302.3)
Ground snow load psf Dwelling unit penetrations (R302.4)
Ultimate design wind speed 160 mph
Wind exposure category (R301.2.1.4) 2-C
High wind design criteria applicable
(R301.2.1.1)
Seismic design category (SDC)
[Figure R301.2(2)]
SDC C&D provisions (R301.2.2)
Weathering NEG
Frost line
Termite
VH
Decay area
Winter design temperature
Ice barrier underlayment required
Flood hazards
FIRE-RESISTANT CONSTRUCTION (R302)
Exterior walls
(R302.1, Tables R302.1(1) and R302.1(2)]
Townhouse separation (R302.2)
Continuity and structural independence
(R302.2.1, R302.2.4)
ROOM PLANNING REQUIREMENTS (R303 through R305)
Dwelling/garage opening/penetration protec-
tion (R302.5)
Dwelling/garage fire separation (R302.6)
Under -stair protection (R302.7)
Wall and ceiling finishes (R302.9)
Flame spread index (R302.9.1)
Smoke -developed index (R302.9.2)
Testing (R302.9.3, R302.9.4)
Insulation (R302.10)
Flame spread/smoke-developed
(R302.10.1, R302.10.2)
Cellulose loose -fill and exposed attic
insulation (R302.10.3, R302.f0.4)
Testing (R302.10.5)
Fireblocking (R302.11)
Draftstopping (17302.12)
Fire protection of floors (R302.13)
Combustible insulation clearance (R302.14)
Use
Area (112)
Width
Ceiling heightt
Natural light*
Natural ventilation'
Living
70
T-O"
7'-0"
8%floor area
4%floor area
Dining
70
7'-0"
7'-0"
8%floor area
4%floor area
Kitchen
N.A.
N.A.
7'-0"
8%floor area
4%floor area
Bedroom
70
T-O"
7'-0"
8%floor area
4%floor area
Bathroom
N.A.
N.A
6'-8"
3 square feet
1 VZ square feet
See Sections R303.1 & R303.3 for mechanical ventilation and artificial light and R303.4 for required whole -house mechanical ventilation.
t 6'-8" min. at plumbing fixtures and for non -habitable basements.
X Required heating (R303.9)
SANITATION (R306 and R307)
X Water closet
X Lavatory
X Tub or shower
X Kitchen area with sink
X Sanitary sewer (Chapter 30)
X Private disposal (Appendix 1)
GLAZING (R308)
Identification (R308.1)
Louvered windows or jalousies (R308.2)
Human impact loads/hazardous locations
(R308.3, R308.4)
Skylights and sloped glazing (R308.6)
-3-
BUILDING PLANNING (cont'd.)
GARAGES AND CARPORTS (R309)
X Floor surface noncombustible; sloped floor
(R309.1)
Carport: open two sides; noncombustible
floors; sloped floor (R309.2)
Automatic garage door opener (R309.4)
Fire sprinklers (R309.5)
EMERGENCY ESCAPE AND RESCUE OPENINGS
(R310)
Where required (17310.1)
Areas, height, width, operations (R310)
Window wells (R310.2.3)
decks and porches (R310.2.4)
Bars, grilles, covers and screens (R310.4)
MEANS OF EGRESS (R311)
X General (R311.1)
X Egress door (R311.2)
Landings at exterior doors
(R311.3 - R311.3.3)
Vertical egress (R311.4)
Construction and attachment (R311.5)
X Hallways (R311.6)
Stairway width, headroom, vertical rise, walk -
line (R311.71 - R311.74)
Stairway treads, risers profiles
(17311.75 - R311.7.5.4)
Stairway landings and walking surfaces
(R311.76, R311.77)
Handrails required (R311.78)
Handrail height, continuity, grip -size
(R311.78.1 - R311.7.8.4)
Stairway illumination (R303.7, R311.79)
Special stairways (R311.710)
Ramp slope, landings, handrails (R311.8)
GUARDS AND WINDOW PROTECTION (R312)
Required for open -sided surfaces, stairs,
ramps and landings > 30" above floor/
grade (13312.1.1)
Height - 36" (R312.1.2)
Opening limitations (R312.1.3)
Window fall protection (R312.2)
AUTOMATIC FIRE SPRINKLER SYSTEMS (R313)
Townhouses (17313.1)
One- and two-family dwellings (R313.2)
SMOKE ALARMS (R314)
Referenced standards (R314.1)
Location and interconnection
(R314.3, R314.4)
Power source (R314.6)
CARBON MONOXIDE ALARMS (R315)
New construction (R315.1, R315.2)
Existing construction (R315.2.2)
Referenced standard (R315.6)
FOAM PLASTIC (R302.8, R316)
Labeling (R316.2)
Surface burning, thermal barrier, specific
approval (R316.3 - R316.8)
DECAY AND TERMITE PROTECTION (R317 and R318)
X Protection required
(Table R301.2(1), R3171, R318.1)
Quality mark (R3172 and R318.1.1)
SITE ADDRESS (R319)
Address numbers (R319.1)
ACCESSIBILITY (R320)
Type B dwelling units applicable (R320.1)
ELEVATORS/PLATFORM LIFTS (R321)
Referenced standards (17321.1 - R321.3)
FLOOD -RESISTANT CONSTRUCTION (R322)
General (R322.1)
Hazard area and requirements
(R301.2.4, R309.3, R322.2, R322.3)
Design professional (R322.3.6)
STORM SHELTERS (R323)
General/referenced standard (R323.1)
SOLAR ENERGY SYSTEMS (R324)
System, installation, access
(17324.2 - R324.7)
MEZZANINES (R325)
Area, egress, openness (13325.2 - R325.5)
SWIMMING POOLS, SPAS AND HOT TUBS (R326)
ISPSC (R326.1)
-4-
FOUNDATIONS (Chapter 4)
MATERIALS (R402)
Wood foundations (17402.1)
Concrete, compressive strength
(R402.2, R402.3)
FOOTINGS (R403)
x Soil bearing value (13401.4, R403.1)
x Footing width
(Tables R403.1(1) - R403.1(3)]
Footing edge thickness; footing projection =
2" minimum, but _<footingthickness
(R403.1.1)
Footings in SDC and D
(R403.1.2 and R403.1.6.1)
x Depth below (outside) grade = 12" minimum;
but below frost line (13403.1.4, R403.1.4.1)
Sill plate bolting in concrete/masonry =1/2° di-
ameter bolts, within 12" but not less than 7
bolt diameters from ends, 7" embedment
(R403.1.6)
Footings adjacent to slopes (R403.1.7)
Frost -protected shallow foundations (R403.3)
Footings for precast concrete foundations
(R403.4)
FOUNDATION/RETAINING WALLS (R404 - R406)
Masonry foundation walls (R404.1.2)
Wall height, unbalanced backfill, nominal
.thickness (Tables R404.1.1(1) -
R404.1.1(4), R404.1.5.1]
Reinforcement size and spacing
(Tables R404.1.1(2) - R404.1.1(4)]
Concrete foundation walls (R404.1.3)
Wall height, unbalanced backfill; nominal
thickness (Tables R404.1.2(1) -
R404.1.2(8), R404.1.5.2]
Horizontal and vertical reinforcement size and
spacing (Tables R404.1.2(1) -
R404.1.2(8), R404.1.3.2, R404.1.3.3.7]
Stay -in -place forms (R404.1.3.3.6.1)
SDC D provisions (R404.1.4)
Height above finished grade (R404.1.6)
Sillplate size (R404.3)
Precast concrete foundation walls (R404.5)
Drains required if habitable or usable spaces
are below grade* (R405)
Soil class (Table R405.1)
Dampproofing if basements are below grade*
(R406.1)
Waterproofing if high water table* (R406.2)
* If uninhabitable; see Under -Floor Space (17408)
COLUMNS (R407)
Protection from decay or corrosion
(R407.1 and R407.2)
x Structural requirements (R407.3)
Anchorage (R407.3)
Wood columns (minimum 4" square) (R407.3)
Steel columns (minimum 3" diameter, Sched-
ule 40 pipe) (R407.3)
UNDER -FLOOR SPACE (R408)
Ventilation (R408.1 and R408.2)
Unvented crawl space (R408.3)
Access (R408.4)
Removal of debris (R408.5)
Finished grade (R408.6)
Flood resistance (R408.7)
-5-
FLOORS (Chapter 5)
WOOD JOISTS AND GIRDERS (R502)
Species and grade (13502.1)
Joists —Sleeping areas, LL = 30 pal
(Table R502.3.1(1)]
Joists—Nonsleeping areas, LL = 40 psf
[Table R502.3.1(2)]
Cantilevered joists
(Tables R502.3.3(1) and R502.3.3(2)]
Girder and header spans
(Tables R602.7(1) - R602.7(3)]
Joists under bearing partitions (R502.4)
Bearing (1.5" minimum on wood or metal; 3"
on masonry or concrete) and lapped joists
(3") (13502.6, R502.6.1)
Lateral restraint and bridging
(13502.7, R502.71)
Drilling and notching (R502.8)
Fastening (R502.9)
Framing of openings (13502.10)
Wood trusses (R502.11)
Draftstopping (R502.12)
LUMBER FLOOR SHEATHING (R503.1)
Allowable span (Table R503.1)
End joints (R503.1.1)
WOOD STRUCTURAL PANEL SHEATHING (R503.2)
Grade (R503.2.1)
Thickness (R503.2.1)
Allowable spans
(Tables R503.2.1.1(1) and R503.2.1.1(2)]
Installation [Table 602.3(1)]
PARTICLEBOARD UNDERLAYMENT (R503.3)
Grade (R503.3.1)
Thickness (R503.3.2)
Installation [Table R602.3(1)]
TREATED -WOOD FLOORS (ON GROUND) (R504)
Base course: 4" thick with maximum 114"
gravel or'/," crushed stone (R504.2.1)
Moisture barrier: placed over base course
(R504.2.2)
Materials (R504.3)
STEEL FLOOR FRAMING (R505)
Cold -formed steel; applicability limits;
in -line framing (R505.1)
Structural framing (R505.2)
Material (R505.2.1)
Corrosion protection (R505.2.2)
Identification (R505.2.4)
Fastening (R505.2.5)
Floor construction (R505.3)
CONCRETE FLOORS (ON GROUND) (R506)
X Thickness: 31/2" minimum; Concrete strength
(R506.1)
Support: prepared subgrade; maximum earth
fill = 811; maximum sand or gravel fill L 24"
(R506.2.1)
Base course: 4" graded with 2" maximum
aggregate (R506.2.2)
X Vapor retarder (R506.2.3)
X Reinforcement support (R506.2.4)
EXTERIOR DECKS (R507)
Support, attachment (R5071 - R507.
Plastic composite materials (R5073)
Decking/deck joists (R5074, R5075)
Deck beams (R5076)
Deck posts, connections, footings
(R50771, R5078)
0
WALL CONSTRUCTION (Chapter 6)
WOOD CONSTRUCTION (R602)
Construction
[Figures R602.3(1) and R602.3(2)]
Stud grade (R602.2)
Design/construction (R602.3)
Stud spacing [R602.3.1, Table R602.3(5)]
Interior load -bearing walls (R602.4)
X Interior nonbearing walls: 2" x 3" at 24" o.c.
or 2" x 4" flat at 16" o.c. (R602.5)
Drilling and notching —studs (R602.6)
Drilling and notching —top plate (R602.6.1)
Headers [Tables R602.7(1) - R602.7(3) and
Figure R602.721
Fireblocking (R602.8, R302.11)
Cripple walls (R602.9)
Wall bracing, lines, panels
(R602.10.1, R602.10.2)
Required length of bracing, method
[R602.10.3, R602.10.4, Tables
R602. f0.3(1) and R602. f0.3(3)]
Minimum length, connections, support, joints,
cripple walls (R602.10.5 - R602.10.11)
Wall anchorage (SDC C and D) (R602.11)
Simplified wall bracing (R602.12)
STEEL WALL FRAMING (R603)
General (R603.1)
Structural framing (R603.2)
Material (R603.2.1)
Corrosion protection (R603.2.2)
Identification (R603.2.4)
Fastening (R603.2.5)
Wall construction (17603.3 - R603.5)
Headers (R603.6)
Studs, tracks and structural sheathing
(R603.7 - R603.9)
SHEATHING (R604 and R605)
Wood structural panels (R604)
Particleboard (R605)
MASONRY CONSTRUCTION (R606 - R610)
X General design (13606)
Seismic requirements (R606.12)
Glass unit masonry (R607)
X Exterior concrete wall construction (R608)
X Exterior windows/doors (R609)
Glass unit masonry (13610)
STRUCTURAL INSULATED PANEL WALL
CONSTRUCTION (R610)
Applicability (R610.2)
Materials (R610.3)
Wall panels, construction details
(R610.4 - R610.10)
7-
WALL COVERING (Chapter 7)
INTERIOR WALL COVERING (R702)
Plaster material (R702.2)
Plaster support (R702.2.3)
X Gypsum board materials (17702.3.1)
Gypsum board support, application and fas-
tening (17702.3.2 - R702.3.7)
X Ceramic tile (R702.4)
Other finishes (13702.5 and R702.6)
Vapor retarders (R702.7)
EXTERIOR WALL COVERING (11703)
X Water -resistive barrier (R703.2)
Attachment and minimum thickness
[Table R703.3(1)]
Wood siding (R703.5)
Wood shakes and shingles (R703.6)
Exterior plaster (R703.7)
Stone & masonry veneer (R703.8 & Figure
R703.8); Steel angle lintels-4" minimum
bearing each end (R703.8.3)
Veneer ties: #9 U.S. gage wire;or #22 U.S.
gage by'/B' corrugated metal; horizontal
and vertical spacing; 2.67 square feet
maximum area supported (wind > 30 psf
and SDC C or maximum area =
square feet) (R703.8.4.1)
Flashing (17703.4 and R703.8.5)
Exterior insulation and finish systems
(R703.9)
X Fiber cement siding (R703.10)
Vinyl siding (17703.11)
Other sidings (R703.12 - R703.17)
ROOF -CEILING CONSTRUCTION (Chapter 8)
WOOD ROOF FRAMING (R802)
Fire -retardant -treated wood (R802.1.5)
X Framing details (13802.3)
Rafter ties (13802.3.1)
Collar ties (4' o.c., in upper third of attic)
(R802.3.1)
Purlins (2" x 4" at 4' o.c. minimum)
(Figure R802.5.1, R802.5.1)
Bearing (R802.6)
Cutting and notching (13802.7)
X Engineered wood products (R802.7.2)
Lateral support and bridging (13802.8)
X Framing of openings (R802.9)
X Wood trusses (13802.10)
X Roof tie -down (17802.11)
CEILING JOISTS [Tables R802.4(1), R802.4(2)]
Without attic storage, LL = 10psf
With attic storage LL = 20psf
Spacing
Species and grade
X Span
X Size
RAFTERS [Tables R802.5.1(1) - R802.5.1(8)]
Ground snow load/LL = 20 psf
Controlling design (LL or snow)
Ceiling not attached/ceiling attached
Spacing
Species and grade
Span
Size
He/HR; Adjustment factor
ROOF SHEATHING (R803.2)
Grade
X Thickness
FRTW allowable stresses/grading
XAllowable spans [Table R503.2.1.1(1)]
X Installation (17803.2.3)
S�
ROOF -CEILING CONSTRUCTION (cont'd.)
STEEL ROOF FRAMING (R804)
General (R804.1)
Structural framing (R804.2)
Material (R804.2.1)
Corrosion protection (R804.2.2)
Identification (13804.2.3)
Fastening (13804.2.5)
Roof construction (R804.3)
Roof tie -down (R804.3.8)
ROOF VENTILATION (R806)
X Ventilation requirements (13806.1 - R806.5)
ATTIC ACCESS (R807)
X Access requirements (807.1)
ROOF ASSEMBLIES (Chapter 9)
ROOF CLASSIFICATION (R902)
X Roof covering materials (R902.1)
WEATHER PROTECTION (R903)
Flashing (R903.2)
Coping (R903.3)
Roof drainage (R903.4)
MATERIALS (11904)
Compatibility; specifications; physical charac-
teristics; identification (R904.2 - R904.4)
REQUIREMENTS FOR ROOF COVERINGS (R905)
X Underlayment (R905.1.1, R905.1.2)
Asphalt shingles (R905.2)
Clay and concrete tile (R905.3)
Metal roof shingles (R905.4)
Mineral -surfaced roll roofing (R905.5)
Slate shingles (R905.6)
Wood shingles (R905.7)
Wood shakes (R905.8)
Built-up roofs (13905.9)
X Metal roof panels (R905.10)
NOA / PA Modified bitumen roofing (17905.11)
NOA / PA Thermoset single -ply roofing (17905.12)
NOA / PA Thermoplastic single -ply roofing (R905.13)
NOA / PA Sprayed polyurethane foam roofing (R905.14)
NOA / PA Liquid -applied roofing (R905.15)
NOA / PA Photovoltaic shingles (R905.16)
ROOF INSULATION (R906)
General (R906.1)
ROOFTOP - MOUNTED PHOTOVOLTAIC SYSTEMS
(R907)
Materials and installation (R9071 - R9075)
REROOFING (R908)
Materials and methods (R908.1)
Structural support (R908.2)
Replacement/re-covering (13908.3, R908.4)
ROOFTOP - MOUNTED PHOTOVOLTAIC
PANEL SYSTEMS (R909)
Materials and installation (R909.1 - R909.3)
CHIMNEYS AND FIREPLACES (Chapter 10)
MASONRY FIREPLACES (111001)
Construction
(Figure R1001.1 and Table R1001.1)
SDC D reinforcing/anchorage
(R1001.3 and R1001.4)
Firebox walls and dimensions
(171001.5 and R1001.6)
Steel fireplace units (R1001.5.1)
Lintel (noncombustible) (R1001.7)
Hearth extension (171001.9, R1001.10)
Fireplace clearance (171001.11)
Fireblocking (R1001.12)
MASONRY CHIMNEYS (R1003)
Construction (Table R1001.1, R1003.2,
R1003.3, and Figure R1001.1)
Corbeling (R1003.5)
in
CHIMNEYS AND FIREPLACES (cont'd.)
Changes in dimension (R1003.6)
Additional load (R1003.8)
Termination (R1003.9)
Spark arrestors (R1003.9.2)
Wall thickness; >_ 4" (R1003.10)
Flue lining - material installation
(R1003.11 and R1003.12)
Multiple flues (R1003.13)
Flue area (appliance) (R1003.14)
Flue area (masonry fireplace) (R1003.15)
Inlet (R1003.16)
Cleanout opening (R1003.17)
Chimney clearance (R1003.18)
Fireblocking (R1003.19)
Chimney crickets (171003.20)
FACTORY -BUILT FIREPLACES (111004)
Listed and labeled (171004.1)
Installation (R1004.2 - R1004.5)
FACTORY -BUILT CHIMNEYS (111005)
Listed and labeled (R1005.1)
Installation (R1005.3 and R1005.4)
EXTERIOR AIR SUPPLY (R1006)
Intake size (111006.2, R1006.4)
ENERGY EFFICIENCY (Chapter 11)
Compliance; information Electrical (N7104)
(N1101.5, N1101.13) Simulated performance (N1105)
Climate zone (Table N1101.7) ERI compliance alternative (N1106)
Building thermal envelope (N1102) Existing buildings (N1107 - N1111)
Systems (N1 f03)
MECHANICAL (Chapters 12-23)
Appliance labeling (141302, M1303)
Chimney and vent location and terminations
(Chapters 10 and 18)
Appliance access (M1305, M1401)
Special equipment (Chapter 19) �
Appliance installation (141307)
Boilers/water heaters (Chapter 20)
Heating and cooling equipment; load calcula-
Hydronic piping (Chapter2l)
tions (Chapter 14)
Special piping and storage systems
Exhaust systems (Chapter 15)
(Chapter22)
Duct systems (Chapter 16)
Solar thermal energy systems (Chapter
23)
Combustion air (Chapter 17)
Penetrations of fire -resistance rated assem-
blies (17302.4, R302.5)
FUEL GAS (Chapter 24)
Application (G2401.1)
Clearances (G2409)
General regulations (G2404)
Electrical and electrical bonding
(G2410, G2411)
Appliance location (G2406)
Pipe sizing (G2413)
Air requirements (G2407)
Piping materials (G2414)
Installation (G2408)
-10-
FUEL GAS (cont'd)
Piping installation (G2415 and G2419) Venting (G2425 - G2429)
Piping support (G2418 and G2424) Misc appliances
Valves, controls, connections (G2423, G2430 - G2454)
(G2420, G2421 and G2422)
PLUMBING (Chapters 25-33)
Water service location and depth Freezing protection (P2904.2.3)
(P2603, P2604) Sprinkler coverage (P2904.2.4)
Sanitary and storm sewer location and depth
(P2603, P2604)
Piping support (Table P2605.1)
Listed plastic materials (P2609)
Plumbing fixtures (Chapter27)
Water heater size and location (Chapter28)
Water supply and distribution system -design
and calculations (Chapter29)
Dwelling unit fire sprinkler systems (172904)
NFPA 13D system (P2904.1)
Temperature rating
(P2904.2.1, P2904.2.2)
Piping materials (P2904.3)
Flow rates (P2904.4.1, P2904.4.2)
Water supply capacity (P2904.5.2)
Pipe sizing (P2904.6)
Drain, waste and vent pipe sizing and riser
diagram (P3004, P3005, Chapter3l)
Sumps and ejectors (P3007)
Backwater valves (P3008)
Fixture traps (P3201)
Storm drainage (Chapter 33)
Penetrations of fire -resistance rated assem-
blies (R302.4, R302.5)
ELECTRICAL (Chapters 34-43)
Penetrations of fire -resistance rated assem- Wiring methods (Chapter38)
blies (E3402.2)
Required lighting and receptacle outlets
Listed and labeled materials (E3403) (E3901, E3903)
Service equipment and location
(E3405, E3601, E3606)
Service size and load calculations (E3602)
Available fault current (E3606)
System grounding (E3607)
Required branch circuits (E3703)
Feeder requirements and load calculations
(E3704)
Ground -fault and arc -fault circuit -interrupter
protection (E3902)
Devices and lighting fixtures (Chapter 40)
Appliance installation (Chapter4l)
Swimming pools (Chapter42)
Class 2 remote -control, signaling and power -
limited circuits (Chapter43)
MANUFACTURED HOUSING USED AS DWELLINGS (Appendix E)
Provisions adopted (17102.5)
Compliance with Appendix E verified
PASSIVE RADON GAS CONTROLS (Appendix F)
Provisions adopted (R102.5) Compliance with Appendix F verified
PATIO COVERS (Appendix H)
Provisions adopted (R102.5) Compliance with Appendix H verified
PRIVATE SEWAGE DISPOSAL (Appendix 1)
Provisions adopted (R102.5) Compliance with Appendix I verified !
EXISTING BUILDINGS AND STRUCTURES (Appendix J)
Provisions adopted (R102.5) Compliance with Appendix J verified
SOUND TRANSMISSION (Appendix K)
i
Provisions adopted (R102.5) Compliance with Appendix K verified
I
HOME DAY CARE—R-3 OCCUPANCY (Appendix M)
Provisions adopted (R102.5) Compliance with Appendix M verified
AUTOMATIC VEHICULAR GATES (Appendix O)
Provisions adopted (R102.5) Compliance with Appendix O verified
SOLAR -READY PROVISIONS (Appendix U)
Provisions adopted (R102.5) Compliance with Appendix U verified
NOTES
u
5P2