HomeMy WebLinkAboutREVISION - BUILDING PERMITOFFICE USE ONLY:
FILE COPY
/
DATE FILED: "C — C5:-tq PERMIT # I -xO 5 0 y
REVISION FEE: --,V-75 RECEIPT # I ably
mw- (4o
ft M14
4PR 1
pe"77wi o" ft
St. to ec�4n�]#RF
r
LOCATION/SITE
ADDRESS: /-'�
PLANNING & DEVELOPMENT
BUILDING & CODE REGULATION
2300 VIRGINIA AVE
FORT PIERCE, FL 349E
(772)462.1553
APPLICATION FOR BUILDING PE
PROJECT INFORMATION
F-e2 Ao
DETAILED DESCRIPTION OF PROJECT
St. Lucie County
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CBC051145 ST. LUCIE CO CERT. #:
BUSINESS NAME: GRBK GHO HOMES LLC
QUALIFIERS NAME: WILLIAM HANDLER
ADDRESS: 590 NW MERCANTILE PLACE
CITY: PORT ST LUCIE STATE: FL ZIP: 34986
PHONE (DAYTIME): 772-873-1711 FAX: 561-688-0909
OWNER/BUILDER INFORMATION:
NAME: GRBK GH MEADOWOOD LLC
ADDRESS: 590 NW MERCANTILE PLACE
CITY: PORT ST LUCIE STATE: FL ZIP: 34986
PHONE (DAYTIME: 772-873-1711 FAX: 561-688-0909
ARCHITECT/ENGINEER INFORMATION:
NAME: NUELLE ENGINEERING
ADDRESS: 11634 SW ROWENA ST
CITY: PORT ST LUCIE
PHONE (DAYTIME): 561-629-6975
SLCCC: 9123109
Revised 06130117
STATE: FL
p
ZIP: 34987
C 8 k a- 0 5�
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MW-60
Builder Name: GHO HOMES
Street: 2654 CONIFER DR
Permit Office: ST. LUCIE BLDG DPTMNT
City, State, Tip: FORT PIERCE, FL, 34951
Permit Number.
Owner.
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types(1830.1 sgfL)
Insulation Area
a. Concrete Block - Exl Insul, Exterior
R=4.0 1632.60 ft'
2. Single family or multiple family Single-family
b. Frame - Wood. Adjacent
R=11.0 197.56 ff2
3. Number of units, if multiple family 1
c. N/A
R= it,
4. Number of Bedrooms 2
d. N/A
R= ft'
10. Ceiling Types (1832.0 sgft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=40.0 1832.00 ft'
6. Conditioned floor area above grade (W) 1832
b. N/A
R= W
c. WA
R
Conditioned floor area below grade (W) 0
11. Ducts
R fP
7. Windows(263.7 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main
6 613
a. U-Factor. Dbl, U=0.62 263.67 f'
SHGC: SHGC=0.26
ft.
12. Cooling systems
kBtu/hr Efficiency
b. U-Factor: NIA
a. Central Unit
36.0 SEER:16.00
SHGC:
c. U-Factor. NIA ft'
SHGC:
13. Heating systems
kBlulhr Efficiency
d. U-Factor: NIA ft'
a. Electric Strip Heal
24.8 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 0.000 ft.
Area Weighted Average SHGC: 0.260
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1832.0 sgft.) Insulation Area
EF: 0.900
a. Slab -On -Grade Edge Insulation R=0.0 1832.00 W
b. Conservation features
b. N/A R= ft'
None
c. WA R= ft'
15. Credits
Pstat
Glass/Floor Area: 0.144 Total Proposed Modified Loads: 59.01
PASS
Total Baseline
Loads: 61.28
I hereby certify that the plangkind speci (cations covered by
Review of the pions and
OjgtiES]gls
this calculation are in complian . with tl a Florid Energy
specifications covered by this
v z Off,
Code. /,
calculation indicates compliance
}V-^
with the Florida Energy Code.
I+ umr- "•••. k;:..:•°`� „
PREPARED BY:
DATE: eN9
Before construction is completed
this building will be Inspected for
compliance with Section 553.908
u� p
0 -Gitrj - a
I hereby certify that this building, as deslg ed, is in compliance
Florida Statutes.
with the Florida Energy. Code.
COD tYE•►�J
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed In accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation. Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
4/8/2019 9:36 AM EnergyGaugeO USA Section R405.4.1 Compliant Sof��tp'9 f� `�O Pagel of 4
0 0, O�
F
u1eil It CI RARAAn%f NLICf•1e1 IQT DCDftl7T
rGRIW R4UYGV 1 / nor V I .aunun'+I� • v1 .ry
PROJECT
Tide:
Building Type:
Owner Name:
# of UnlW.
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/E)dsting:
Comment.
toMl-80 Bedrooms: 2
User Conditioned Area: 1032
Total Stories: 1
1 Worst Case: No
OHO HOMES Rotate Angle: 0
ST. LUCIE BLDG DPTMNT Cross Ventilaton: No
Whole House Fan: No
Single-family
New (From Plans)
Address Type: Street Address
Lot #
BlocIdSubdNislon:
PlatBook:
Street: 2654 CONIFER DR
County: St. Lude
City, State, Zip: FORT PIERCE,
FL, 34951
CLIMATE
Design Location
Design Temp
TMY Sfte 97.5 % 2.5 %
Int Design Tamp Heating Design Daily Temp
Winter Summer Degree Days Molsture Range
FL, Fort Plerce FL VERO_BEACH MUNI 39 90
70
75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Bloekl
1832 17037.6
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InOI ID Finished Cooled Heated
1
Main
1832 17037.6 Yes 3
2
1 Yes Yes Yes
FLOORS
#
Floor Type
Spaoe Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 166.5 it 0
1832 h'
.— 0 0 1
ROOF
#
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emht Emitt Deck Pitch
Tested Tested Insul. (deg)
1
Hip
Concrete 2049 ftz 0 ft' Medium
0.4
N 0.9 No 0 26.6
ATTIC
/
V #
Type
Ventilation Vent Redo (1 In)
Area
ROB IRCC
1
Fug adic
Vented 150 1832 IF
N N
CEILING
#
Calling Type
Space R-Value Ins Type Area Framing Fran Truss Type
1
Under Atdc (Vented)
Main 40 Blown
1832 1? 0.1 Wood
4/=019 9:36 AM EnergyGauge® USA Section R405A.1 Compliant Software Page 2 of 4
FORM R405-2o47 INPUT SUMMARY CHECKLIST REPORT
WALLS
gd(acant
Cavity Width Height
Sheathing Framing Solar
BBlow
Al
Cant
Space
WAII T4gpn
Ama
_ 1
N
Exterior Concrete Black- Ext Insul Main
4 43 7 9
4
406.8 flit
0
0 0.3
0
-2
E
Exterior Concrete Block - Ext Insul Main
4 63 10 9
4
502.4 g'
0
0 0.3
0
-3
S
EMedor Concrete Block- Ext Insul Main
4 19 6 9
4
182.0 ft'
0
0 0.3
0
-4
W
Exterior Concrete Block - Ext Insul Main
4 58 0 9
4
541.3 flit
0
0 0.3
0
5
-
Garage Frame - Wood Main
11 21 2 9
4
197.6 ft'
0
025 0.3
0
DOORS
#
Dint DocrType Space
storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S Wood Main
None
.39
3
8
24 ft'
WINDOWS
Orientation shown Is the entered, Proposed orientation.
/
Well
Overhang
V
0
Omt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
_
1
n 1 Metal Double (Clear) Yes
0.62 026 N
30.01P
0 It 0 In
0It 0 In
None
None
_
2
n 1 Metal Double (Clear) Yes
0.62 026 N
36.0 R'
0 ft 01n
0 It 0In
None
None
3
n 1 Metal Double (Clear) Yes
0.62 026 N
96.0 ft'
o it 0In
0 ft 01n
None
None
_
4
e 2 Metal Double (Clear) Yes
0.62 0.26 N
12.0 ft'
0 8 0 in
0 ft 0 in
None
None
5
B 2 Metal Double (Gear) Yes
0.62 026 N
7.0 IF
0 It 0In
0 ft 0 In
None
None
6
e 2 Metal Double (Gear) Yes
0.62 026 N
21.7 ft'
0 It 0In
0 ft 0 in
None
None
7
5 3 Metal Double (Clear) Yes
0.62 026 N
26.0 ft'
0It 0 in
0 ft 0 in
None
None
_
8
w 4 Metal Double (Clear) Yes
0.62 028 N
20.0 ft'
0 ft 0 to
0 R 0 in
None
None
9
W 4 Metal Double (Clear) Yes
0.62 0.26 N
15.0 ft'
0 ft 0 in
0 it 8 in
None
None
GARAGE
#
Floor Area Calling Area
Exposed Wall Perimeter
Avg. Well Height
Exposed Wall Insulation
1
584 ft' 564 flit
64 it
8 ft
1
INFILTRATION
#
Scope
Method SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(60) .000414
1987.7 109.12 20622
.3136
7
HEATING SYSTEM
#
System Type Subtype
Efficiency
Capacity
Block
Duds
1
Electric Strip Heat/ None
C0121.1
24.82 kBlulhr
1
sys#1
Q812019 9:36 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 4
INCH IT CI IMMADV d%U=fLIfi IQT PPPnPT
-
COOLING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Air Flow SHR
Block
Duds
1 Central Unit/
Split
SEER: 16
36 k81Whr
108D cfm
0.7
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnl
Conservation
1 Electric
None
Garage
0.9 50981 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
tt'
DUCTS
—Supply—
—Return—
Air
CFM 25 CFM25
HVAC#
J # Location R-Value Area
Location
Area Leakage Type
Handier
TOT OUT
ON
RLF
Heat Cool
_ 1 Attic
6 613 fN
Attic
4451P Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Y
Programablr0e0'ThermostatJan:
Crfoiiling Fans:
Feb
I�7f11 Mar
ff 11
MayfXI
Jun [ 1 Jul
IX1
() Aug
Sep
Oct
[fX]1 Nov
Nov
Dec
If7(�1 Dec
V�H g l ] Jan ( ] Feb
IXJ Ma
[Xj pr
` ] May Jun Jul
Aug
Sep
[X)
[)
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8 9
10
11
12
Cooling.(WD) AM
78
78 78
78 78 78
78
78 80
so
80
80
PM
80
80 78
78 78 78
78
78 78
78
78
78
Cooling.(WEH) AM
78
78 78
78 78 78
78
78 78
78
78
78
PM
78
78 78
78 78 78
78
78 78
78
7
78
Healing (WD) AM
68
Be 68
68
66
68
6688 Be
68 68 688
6688
6666
666
Heating(WEH) AM
66
66 66
66 68 68
Be
68 Be
68
68
68
PM
68
Be 68
68 g8 68
68
68 68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction Space
Delaul B lbsIsq.ft.
0 R•
0 6
0.3
Main
Name: Signature:
Rating Compant: Date:
4/812019 9:36 AM EnergyGaugeG USA Section R405.4.1 Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R 6.0
c) AHU location Attic/Attic
3. No. of units (If multiple -family)
3. 1
4. Number of bedrooms
4. 2
13. Cooling system: Capacity 36.0
a) Split system SEER 16.0
5. Is this a worst case? (yesino)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned Floor area (sq. ft.)
6. 1832
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.620
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.260
14. Heating system: Capacity 24.8
c) Area ^
7c. 263.7
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP 1.0
a) U-factor.(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
0 Other
9. Floor type, Insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water healing system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF 0.90
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior.
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2. 4.0
0 Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131. 11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a. 40.0
b) Cross ventilation No
b) Single assembly
111J.
c) Whole house fan No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
0 Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, If not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installe , (or exceeded) in this home before final Inspection. Otherwise, a new EPL
display card will be completed base on installed code compliant features.
Builder Signature:
/�
Date: -1"Z I 1 G
Address of New Home: 2654 CONIF DR
City/FL Zip: FORT PIERCE, FL 34951
4/8/2019 9:36:31 AM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 61h Edition (2017) Compliant Software Page 1 of 1
1- wrightsoft Load Short Form dot'
Date: Nov a, 2018
Entire House By:
Project Information -
For. MW-60
2654 CONIFER DR, FORT PIERCE, FL 34951
Design
Htg
Clg Infiltration
Outside db.(°F)
43
91 Method Simplified
Ins Ida db(°F)
70
72 Construction quality Average
Design TD (eF)
27
19 Fireplaces 0
Daily range
-
L
Inside humidity (%)
30
50
Moisture difference (grfib)
0
65
HEATING EQUIPMENT COOLING EQUIPMENT
Make
Make Carrier
Trade
Trade 16 SEER PURON AC
Model
Cond CA16NA036""'A
AHRI ref
Coil FV4CNB006
AHRI ref 4584643
Efficiency
100 EFF
Efficiency 13.7 EER. 16.5 SEER
Heating input
7.3
kW
Sensible cooling
24500 Btuh
Heating output
24817
Btuh
Latent cooling
10500 Btuh
Temperature rise
19
eF
Total cooling
35000 Btuh
Actual air flow
1167
elm
Actual air flow
1167 cfm
Air flow factor
0.048
cfm/Btuh
Air flow factor
0.050 cfm/Btuh
Static pressure
0
in H2O
Static pressure
0 in H2O
Space thermostat
Load sensible heat ratio
0.66
ROOM NAME
Area
(ft2)
Htg load
(Btuh)
Gig load
(Btuh)
Htg AVF
(cfm)
Clg AVF
(Cfm)
MASTER SUITE
312
5031
3595
240
181
HER WIC
60
931
418
44
21
MASTER BATH
169
1787
1793
85
90
BED 2
205
2394
2837
114
143
UTILITY
72
587
905
28
46
BATH 2
79
64
199
3
10
FOYER
100
775
585
37
29
DINING
130
3710
3528
177
178
KITCHEN
151
1745
2219
83
112
DEN
179
3821
3271
182
165
3659
3804
174
192
GREAT RM
373
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2019Apr-08 09:23.35
wrighttSOft RIgMSuIeO UNvarsal 201212.1.05 RSU02818 page t
/iCIMCAUsaraUaWn1Dooements1Wd9Mse8HVACOW-0O.mp Cale aNUS Front Doorfaces:5
Entire House
1831
24504
23154
1167
1167
Other equip loads
0
0
Equip. @ 0.95 RSM
22112
Latent cooling
12153
A onA
nAenA
1 aA'fRG
ii R7
1197
...
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wri htsoft 2019Apr-080&23:35
9 RightSulte® UNvereal 201212.1.05 RSU02818 Paget
ACC\ CAUseeuasWDowmenls1WdghkoR HVACXMW-60.mp Calc=MJ8 Front Doarlaws: S
wrightsoftProject Summary
Entire House
Project Information
For: MW-60
2654 CONIFER DR, FORT PIERCE, FL 34951
Notes:
Desiqn Information
Weather: Vero Beach Municipal AP, FL, US
Job:
Dale: Nov 6, 2078
By:
Winter Design Conditions
Summer Design Conditions
Outside db
43 OF
Outside db
91 OF
Inside db
70 OF
Inside db
72 OF
Design TO
27 OF
Design TO
19 OF
Daily range
L
Relative humidity
50 %
Moisture difference
65 gr/lb
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure
21299 Btuh
Structure
19716 Btuh
Ducts
3205 Btuh
Ducts
3438 Btuh
Central vent (0 cfm)
0 Btuh
Central vent (0 cfm)
0 Btuh
Humidification
0 Btuh
Blower
0 Btuh
Piping
0 Btuh
Equipment load
24504 Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Infiltration
Equipment sensible load
22112 Stuh
Method
Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
10617 Btuh
Ducts
1536 Btuh
Heating Cooling
Central vent (0 cfm)
0 Btuh
Prea (ft2)
1831 1831
Equipment latent load
12153 Btuh
Volume (fe)
18001 18087
Air changes/hour
0.38 0.20
Equipment total load
34265 Btuh
Equiv. AVF (dm)
115 60
Req. total capacity at 0.70 SHR
2.6 ton
Heating Equipment Summary
Cooling Equipment
Summary
Make
Make Carrier
Trade
Trade 16 SEER PURON AC
Model
Cond CA16NA036••••A
AHRI ref
Coil FV4CNB006
AHRI ref 4584643
Efficiency
100 EFF
Efficiency 13.7 EER, 16.5
SEER
Heating Input
7.3 kW
Sensible cooling
24500 Btuh
Heating output
24817 Btuh
Latent cooling
10500 Btuh
Temperature rise
19 OF
Total cooling
35000 Btuh
Actual air Flow
1167 cfm
Actual air flow
1167 cfm
Air Flow factor
0.048 cfm/Btuh
Air Flow factor
0.050 cfm/Btuh
Static pressure
0 in H2O
Static pressure
0 in H2O
Space thermostat
Load sensible heat ratio
0.66
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2019-Apr-0809:23:36
+ wrlghttsoft- RlghtSURCS U&ergo] 201212.1.05 RSU02818 Page 1
�� C:IUsemUasan1D=nnenb1Wn9hLsaO HVACIM -60.mp Cale=MJ8 Front Door taws: S
GHO HOMES
MW-60
2654 CONIFER DR.