Loading...
HomeMy WebLinkAboutCERTIFICATION - DESIGN LOAD COMPLIANCE/8rL - o sW Planning & Development Services DRe t E COPY Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Permit#: Occupancy Type: Construction SCANNED St Lucie Coun tv INSTRUCrIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Building Code Fifth Edition with 20 N/A Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV Exposure Category: _B X C _D 4. Design Wind Velocity 160 mph X ASD _LRFD End Zone Width: 6 ' ft S. Mean Roof Height 19 ft Roof Pitch: 6 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF based on losgft @ MRH, clearly�ab I on all plan open l tzo.0 4-WO *00. 6 t3y,' Y•i- Zone 1: — 7J. A Zone 2: —55,3 Zone 3: — V/, �- Zone 4: — 9jz. 6 Zone 5: --Y6.5 Garage: — 29r, 7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: NIA PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? Yes _2( NotAppliceble Explain Why Not: '}SORT1 a&J -70 , 0'1 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces s I ledr 00A)AI-p T y (o. Print Name Cert # & Co. Cert Auth. Nd�r r,F j�3Nf /N F37�iz r64 Sig ure, Date; and S I 14 3 Y sul "Ld aW s Company Name & Address /_.9� Oo s L vary �L. 3 9 8' �-• Revised 07/25%101 � :COUNTY •r IL '0' R I DA - Project Name: _ Project Address: /g/L -06z3 Planning & Development Services DepartmentContract®r Co py Building & Code Regulations Division JAN 16 2019 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Permit Occupancy Type: Construction Type: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) SG°'gnl o Residential Addition a NFL o Any accessory structure requiring a building permit St 1"Cie r C o Any non-residential structure. OVnI1k • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Building Code Fifth Edition with 20 N/A Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV Exposure Category: _B X C _D 4. Design Wind Velocity ts0 r1 mph X ASD _LRFD End Zone Width:6 ft S. Mean Roof Height / D ft Roof Pitch: 6 :12 Parapet: N/A ft 6. Components & Gadding Design Pressures Used: (PSF, based an 10sgft @ 15'MRH, dearly label on all plan openingsL: .tZO.0 4-W.0 4-oo.0 t3Y. t3y.'� I-2-Y,7 Zone 1:=31. Q Zone 2: —5313 Zone 3: — 2?1, J- Zone 4:—,77.6 Zone 5: ^yG • Garage: ^ 271 7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: RA PSF Dock: N/A pSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? Yes „}Not Applicable Explain Why Not: h50&,-T_ M_'r-70 - q.7 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify That structural elements depicted on these plans provide adequate resistance to the design forces spec' OoA)AI-a T AJOAZZ& SZ aY bo Print Name Cert # & CO. Cen Auth. s re, Date; and se . _1.163`1 .9'0 12.0W6W4- s . 2 iJ �9 Company yNName &Address Revised 07/25/2014