HomeMy WebLinkAboutENERGY EFFICIENCY CODEContrail FARY
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name:
City, Slate,
Owner:
.Design Location:
MW-67
1 2634 CONIFER DR
Zip: FORT PIERCE, FL, 34951
I
FL, Fort Pierce
Builder Name: GHO HOMES SCANNED
Permit Office: ST. LUCIE BLDG DPTMNT
Permit Number: Q g BY
Jurisdiction: I ✓ �-' r oSO a7t, LOCI@ County
County: St. Lucie (Florida Climate Zone 2 )
1. New construcllon or existing
New (From Plans)
9. Wail Types (1830.1 sgfL)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior R=4.0 1632.60 ft2
b. Frame - Wood, Adjacent
R=11.0 197.56 fN
3. Number'of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
2
d. N/A
R= ft2
10. Ceiling Types (1832.0 sgfQ
Insulation Area
5. Is this a worst case?
No
a. Under Attic (Vented)
R=30.0 1832.00 112
6. Conditioned floor area above grade (ft2)
1832
b. N/A
R= ft2
- Conditioned floor area below grade (ft2)
0
c. N/A
R= fP
11. Ducts
R fP
7. Windows(263.7 sgft.) Description
Area
a. Sup: Attic, Rel: Attic, AH: Main
6 629
a. U-Factor: Dbl, U=0.62
263.67 fP
SHGC: SHGC=0,26
•b: U-Factor: N/A
ft.
12. Cooling systems
kBtu/hr Efficiency
CA SHGC:
a. Central Unit
36.0 SEER:16.00
- • •a, U-factor: NIA
ft2
SHGC:
13. Healing systems
kBtu/hr Efficiency
d. U-Factor: NIA
ft.
a. Electric Strip Heat
24.8 COP:1.00
- SHGC:
Area Weighted Average Overhang Depth:
0.000 ft.
Area Weighted Average SHGC:
0.260
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1832.0 sgft.)
Insulation Area
EF: 0.900
a. Slab -On -Grade Edge Insulation
R=0.0 1832.00 ft2
b. Conservation features
b. N/A
R= ft.
None
c. N/A
R= ft.
15. Credits
Pstat
GlasslFloorArea: 0.144
Total Proposed Modified Loads: 57.55
PASS
Total Baseline Loads: 61.28
0
Fhereby certify that the plans and specifications covered by
this calculation are in omplia ce with the Florida Energy
Code.
PREPARED By)
DATE: _-1 -2 1- _ _
I hereby certify Ih�l tfi s b R3, , as tgri�d,'is in compliance
with the Floridar€ner Cod
Review of the plans and
specifications covered by this
calculation Indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be Inspected for
compliance with Section 553.90E
Florida Statutes.
BUILDING OFFICIAL:
DATE:
Compliance requires certificatilbn by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this oro an:
a9velop , leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2
JAN 2 % 2019
1/17/2019 10:55 AM EnergyGauge® USA Section R405.4.1 Compliant Software itting Dep8'40O4t
m
per
St. Lucie County_
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
MW-67
Bedrooms: 2
Address Type: Street Address
Building Type:
User
Conditioned Area: 1832
Lot #
Owner Name:
Total Stories: 1
BlocWSubdivision:
If of Units
1
Worst Case: No
PlatBook:
Builder Name:
GHO HOMES
Rotate Angle: 0
Street: 2634 CONIFER DR
Permit Office:
ST. LUCIE BLDG DPTMNT Cross Ventilation: No
County: St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip: FORT PIERCE,
Family Typpe:
Single-family
FL, 34951
NewlExisting:
New (From Plans)
Comment'
'
CLIMATE
Design Tamp
Int Design Temp Heating Design Daily Temp
u
Design Location
TMY Site 97.5 % 2,5 %
Winter
Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO BEACH MUNI 39 90
70
76 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
1832 17037.6
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Healed
,1
Main
1832 17037.6 Yes 3
2
1 Yes Yes Yes
FLOORS
-_
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
_ _
1 Slab -On -Grade Edge Insulatio Main 166.5 ft 0
1832 ft'
— 0 0 1
ROOF
Roof Gable Roof
Solar
$A Emig Emill Dock Pitch
V If
Type
Materials Area Area Color
Absor.
Tested Tested Insui. (deg)
1
Hip
Concrete 2049 W 0 W Medium
0.4
N 0.9 No 0 26.6,
ATTIC
T
/
V #
Type
Ventilation Vent Ratio (1 In)
Area
RBS IRCC
_ 1
Fug attic
Vented 150 1832 ft'
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frec Truss Type
1
Under Attic (Vented)
Main 30 Blown
1832W 0.1 Wood
I
;J
I
dH
t/171201910:55 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4 �
I
FORM R405-2017 INPUT SUMMARY CHECKLI5T REPORT
WALLS
�//
Adjacent
Cavity Width Height
Sheathing Framing Solar
Below
V #-.O
To___ WAIISYpe�- Space R-Value-Et-In__.FL.-In
Area
R-value_Fiactlon__Absor--Gradai1-
a_ 1 IN
Exterior Concrete Block - Ext Insul Main
4 43 7 9
4
406.8 ft'
0
0 0.3
0
_ 2 E
Exterior Concrete Block - Ext Insul Main
4 53 10 9
4
502.4 R'
0
0 0.3
0
_ 3 S
Exterior Concrete Block - Ext Insul Main
4 19 6 9
4
182.0 ft'
0
0 0.3
0
_ 4 W
Exterior Concrete Block - Ext Insul Main
4 58 0 9
4
541.3 ft'
0
0 0.3
0
_ 5
Garage Frame - Wood Main
11 21 2 9
4
197.8I12
0
0.25 0.3
0
i
DOORS
#
Oml Door Type Space
Storms
U-Value
WidthArea
Ft
In
Ft
11
S Wood Main
None
.39
3
-In
8
24f'
WINDOWS
'V !
Orientation shown is the entered Proposed orientation.
.../
Wall
Overhang
V #
Omt ID Frame Panes NFRC
U.Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1i
n 1 Metal Double (Clear) Yes
0.62 0.26 N
30.0 ft'
0 It 0 in
0 ft 0In
None
None
_ 2
n 1 Metal Double (Clear) Yes
0.62 0.26 N
36.0 ft'
0 ft 0 in
0 It 0 In
None
None
3
^_
n 1 Metal Double (Clear) Yes
0.62 0.28 N
96.0 ft'
0 ft 0In
0 It 0 In
None
None
4
e 2 Metal Double (Clear) Yes
0.62 0.26 N
12.0 ft'
0 ft 0 in
0 ft 0 In
None
None
5
e 2 Metal Double (Clear) Yes
0.62 0.26 N
7.0 ft'
0 It 0In
0 It 0In
None
None
_
_ 6
e 2 Metal Double (Clear) Yes
0.62 0.26 N
21.7 ft'
0 It 0In
0 It 0In
None
None
4_ 7
s 3 Metal Double (Clear) Yes
0.62 0.20 N
26.0 ft'
0 ft Orin
0 ft 0In
None
None
8
IN 4 Metal Double (Clear) Yes
0.62 0.26 N
20.1) ft'
0 It 0 in
0 It 0 in
None
None
_
n. 9
W 4 Metal Double (Clear) Yes
0.62 0.26 N
15.0 ft'
0 ft 0 in
0 ft 0In
None
None
GARAGE
-_ #
Floor Area Calling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
584 ft' 584 W
64 ft
eft
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Whole house Proposed ACH(50) .000295
1419.8 77.95 146.59
.224
5
HEATING SYSTEM
_ #
System Type Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/ None
COP:1
24.82 kB1Whr
1
sys#1
t
1/171201910:55 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts_
_ ,1 Central Unit/
Split
SEER: 16
36 kBtu/hr
1080 cfm
0.7
1
sys#1
HOT WATER SYSTEM
System Type
SubTpe
Location
EF Cap
Use
SetPnt
Conservation
_
7 Electric
None
Garage
0.9 50 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
�FSEC
Collector
Storage
I
ert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
f1'
L
DUCTS
-J —Supply—
—Return
Air
CFM25 CFM25
HVAC#
V # Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
ON
RLF
Heat Cool'
1 Attic
6 62911'
Attic
516 W Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
-^ Programeble Thermostat: Y
- Calling Fens:
„ Cooling [[�j]]Jan �]]Feb
Heating Jan Feb
[[ ]]Mar
[XI Mar
[ j Apr
L J
May Jun 11 Jul
May Jun Jul
Aug
Aug
Sep
Sep
Oct
Oct
Nov
Nov
Dec
Dec
txJ
Venting [ 1 Jan 1 11 Feb
l J
[[�X11 Mer
lxl Apr
f7hermostat Schedule: HERS 2008 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8 9
10
11
12
"Copling (WD) AM
80
80 78
78 78 7B
78
78 78
78
78
78
WCooling (WEH) AM
78
78 78
78 78 78
76
78 78
78
78
78
PM
78
78 78
78 78 78
78
78 78
78
78
78
-Heeling (WD) AM
68
68 68
68 6B 68
68
68 68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68 68
68
68
68
PM
68
68 fib
68 68 68
68
68 68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction Space
_
Default 6 Ibs/s .ft.
0 ft'
Oft
0.3
Main
m :s !Name:
Signature-
1 .UGI
Rating Compant:
Date:
t`
F--
I.
l 1/17/201910:55 AM
i
i'
EnergyGauge® USA Section R405.4.1 Compliant Software
Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans) 12. Ducts, location & Insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family b) Return ducts R
6.0
c) AHU location Attic/Attic
3. No, of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 2 13. Cooling system: Capacity
36.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5. No b) Single package SEER
c) Ground/water source SEERICOP
'
6, Conditioned Floor area (sq. ft.)
6. 1832 d) Room unit/PTAC EER
e) Other
'
7. Windows, type and area
a) U-factor.(weighted average)
7a. 0.620
b) Solar Heal Gain Coefficient (SHGC)
7b. 0.260 14. Heating system: Capacity
24.8
c) Area
7c. 263.7 a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-faclor:(weighted average)
8a. NA d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA e) Gas furnace, LPG AFUE
0 Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b. 15. Water healing system
c) Concrete, raised (R-value)
9c, a) Electric resistance EF
0.90
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
•'
1. Wood frame (Insulation R-value)
10A1, e) Dedicated heat pump with tank EF_
j-
2. Masonry (Insulation R-value)
10A2. 4.0 f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation.R-value)
10B1. 11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and Insulation level
a) Ceiling fans
a) Under attic
11 a. 30.0 b) Cross ventilation
No
b) Single assembly
11b. c) Whole house fan
No
c) Knee walls/skylight walls
11c. d) Multizone cooling credit
d) Radiant barrier installed
11d. No e) Multizone heating credit
f) Programmable thermostat
Yes
'La bet required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
certify that this home has compli¢d with the
Florida Building Code, Energy Conservation, through the above energy
saving features which will be inst led (or exceeded) in this home before final Inspection. Otherwise, anew EPL
/ .
display card will be completed be ad on installed code compliant features.
Builder Signature:_
Address of New Home:
Date: /I�r"II
City/FL Zip: FORT PIERCE, FL 34951
1/17/2019 10:55:42 AM I EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1
FILE COPY
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MW-67
Builder Name: GHO HOMES
Street: 2634 CONIFER DR
Permit Office: ST. LUCIE BLDG DPTMNT
City, State, Zip: FORT PIERCE, FL, 34951
Owner:
Permit Number:
Jurisdiction: 1QQ
1 2+ -
C)S'03
I
Design Location: FL, Fort Pierce
V
County: St. Lucie Climate Zone 2 )
(Florida
1. New conlstruction or existing
New (From Plans)
9. Wall Types(1830.1 sqft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior R=4.0 1632.60 ft'
b. Frame - Wood, Adjacent
R=11.0 197.56 ft'
3. Number of units, if multiple family
1
c. N/A
R= ft'
4. Number of Bedrooms
2
d. N/A
R= ft'
10. Ceiling Types (1832.0 sgft.)
Insulation Area
5. Is this a worst case?
No
a. Under Attic (Vented)
R=30.0 1832.00 ftz
6. Conditioned floor area above grade (ft')
1832
b. N/A
R= ft'
Conditioned floor area below grade (W)
0
c. N/A
R= ft'
11. Ducts
R ft'
7. 'Windows(263.7 sgft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: W1i AN NED 6 629
a: U-Factor: Dbl, U=0.62
263.67 ft'
BY
/s SHGC: SHGC=0.26
b: U-Factor: N/A
ft'
12. Cooling systems St. Lucie COhRtlt�/ Efficiency
-. SHGC:
a. Central Unit
36. SEER:16.00
-- c. U-Factor: N/A
ft'
SHGC:
13. Healing systems
kBlu/hr Efficiency
d. U-Factor: N/A
ft'
a. Electric Strip Heat
24.8 COP:1.00
SHGC:
Area Weighted Average Overhang Depth:
0.000 ft.
Area Weighted Average SHGC:
0.260
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1832.0 sqft.)
Insulation Area
EF: 0.900
a. Slab -On -Grade Edge Insulation
R=0.0 1832.00 ft'
b. Conservation features
b. N/A
R= ft'
None
- c. N/A
R= ft'
15. Credits
Patel
Glass/Floor Area: 0.144
Total Proposed Modified Loads: 57.55
PASS
Total Baseline Loads: 61.28
I hereby certify that the plans and specifications covered by
Review of the plans and
�q¢E Spgr
this calculation are in omplia ce with the Florida Energy
specifications covered by this
0
y' FO�
Code.
calculation indicates compliance
_;
ii„ .
with the Florida Energy Code.
y ,
F rn,,.,.'•••%.:g:� '" ; `� �_�„ e-
PREPARED BY._11
DATE: /
Before construction is completed
this building will be inspected for
compliance with Section 553.90811�
t� AV
"iY,aY�I,.-v..� a
�1
I hereby certify as
lh Is b ' ` ,
u d , is in compliance
Florida Statutes.
y�
with the Florida ner Cod
COD WE1'SLJ
aOWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
Compliance requires certiflcatin by the air handler unit manufacturer that the air handler enclosure qualifies as
" certified factory -sealed in accordance with R403.3.2.1.
•- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope) leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4. 1.2 �EIVE®
RE
JAN 2 2 90103
1/17/2019 10:66 AM
EnergyGauge® USA Section R405.4.1 Compliant
Permitting Depart t e"
St. Lucie County,
�nT
FORM R405-2017
IIVYU I SUIV MAMT 6r1CVr%LIS I RCrVrt I
F
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
- Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
MW-67 Bedrooms: 2
User Conditioned Area: 1832
Total Stories: 1
1 Worst Case: No
GHO HOMES Rotate Angle: 0
ST. LUCIE BLDG DPTMNT Cross Ventilation: No
Whole House Fan: No
Single-family
New (From Plans)
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 2634 CONIFER OR
County: St. Lucie
City, State, Zip: FORT PIERCE,
FL, 34951
CLIMATE
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL,
Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
1832 17037.6
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
Infii ID Finished Cooled Heated
1
Main
1832 17037.6 Yes 3
2
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 166.5 It 0
1832 ft'
---- 0 0 1
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt Emitt Deck Pitch
Tested Tested Insul. (deg)
1
Hip
Concrete 2049 ft' 0 ft' Medium
0.4
N 0.9 No 0 26.6
ATTIC
#
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 1832 ft'
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1832 ft' 0.1 Wood
,
I
is
Ill7/2019 10:55 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4
'Cnone Dnn�r;_onl7 INIPI IT SI IMMARY rHFCKLIST REPORT
WALLS
Adjacent
Cavity Width Height
Sheathing Framing Solar
Below
VS
�-Omt
To WallSype pace
R-Value-FtJn-Et
In
Area
R-Value-Ftaction-Absor-Grada°l
_ 1
N
Exterior Concrete Block - Ext Insul Main
4 43 7 9
4
406.8 ft2
0
0 0.3
0
_ 2
E
Exterior Concrete Block - Ext Insul Main
4 53 10 9
4
502.4 ft2
0
0 0.3
0
_ 3
S
Exterior Concrete Block - Ext Insul Main
4 19 6 9
4
182.0 ft2
0
0 0.3
0
_ 4
W
Exterior Concrete Block - Ext Insul Main
4 58 0 9
4
541.3 ft2
0
0 0.3
0
5
-
Garage Frame - Wood Main
11 21 2 9
4
197.6 ft2
0
0.25 0.3
0
DOORS
#
Omt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S Wood Main
None
.39
3
8
24 ft2
WINDOWS
Orientation shown is the entered. Proposed orientation.
/
Wall
Overhang
V
#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
n 1 Metal Double (Clear) Yes
0.62 0.26 N
30.0 ft2
0 ft 0 in
0 ft 0 in
None
None
2
n 1 Metal Double (Clear) Yes
0.62 0.26 N
36.0 ft2
0 ft 0 in
0 ft 0 in
None
None
3
n 1 Metal Double (Clear) Yes
0.62 0.26 N
96.0 ft2
0 ft 0 in
0 ft 0 in
None
None
4
e 2 Metal Double (Clear) Yes
0.62 0.26 N
12.0 112
0 ft 0 in
0 ft 0 in
None
None
5
e 2 Metal Double (Clear) Yes
0.62 0.26 N
7.0 ft2
0 ft 0 in
0 ft 0 in
None
None
6
e 2 Metal Double (Clear) Yes
0.62 0.26 N
21.7 ft2
0 ft 0 in
0 ft 0 in
None
None
7
6 3 Metal Double (Clear) Yes
0.62 0.26 N
26.0 ft2
0 ft 0 In
0 ft 0 in
None
None
8
w 4 Metal Double (Clear) Yes
0.62 0.26 ' N
20.0 ft2
0 ft 0 in
0 ft 0 in
None
None
9
W 4 Metal Double (Clear) Yes
0.62 0.26 N
15.0 ft2
0 It 0 in
0 ft 0 In
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
584 ft2 584 ft2
64 ft
8 ft
1
INFILTRATION
.#
wF1
Scope
Method SLA
CFM 50 ELA EgLA
ACH
ACH 50
Wholehouse Proposed ACH(50) .000295
1419.8 77.95 146.59
.224
5
HEATING SYSTEM
#
System Type Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip HeaU None
COPA
24.82 kBtu/hr
1
sys#1
I,
1/17/2019 10:55 AM
EnergyGauge® USA Section R405.4.1 Compliant Software
Page 3 of 4
FnR�A 9n17
IMPI IT SIIMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
SEER: 16
36 kBtu/hr
1080 cfm
0.7
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
_
1 Electric
None
Garage
0.9 50 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft'
DUCTS
Supply--
--- Return ----
Air
CFM 25 CFM25
HVAC#
V
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
ON
RLF
Heat Cool
1 Attic
6 629 ft'
Attic
515 ft' Default Leakage
Main
(Default) (Default)
1 1 ^
TEMPERATURES
Programablee Thermosta[[t:]]Y
Calling Fans:
Heating [Xl Jan [X] Feb
Mar
r[f[ ]]
EE
Aug
r[X]'gap r
S
Oct
[rX']
Nov
Dec
INovr7C,)
Dec
Venting ll 1) Jan [[ 11 Feb
X
X Mar
Apr
[ May Jun lXl Jul
[Xj
[ ] p
[X]
[ ]
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8 9
10
11
12
Cooling (WD) AM
78
78
78
78 78 78
78
78 80
80
80
80
PM
80
80
78
78 78 78
78
78 78
78
78
78
Cooling (WEH) AM
78
78
78
78 78 78
78
78 78
78
78
78
PM
78
78
78
78 78 78
- 78
78 78
78
78
78
^�Heating(WD) AM
66
66
66
66 66 68
68
68 68
68
68
68
+. PM
68
68
68
68 68 68
68
68 68
68
66
66
'Heating (WEH) AM
66
66
66
66 66 68
68
68 68
68
68
68
PM
68
68
68
68 68 68
68
68 68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ft'
0 ft
0.3
Main
Name:
Rating Compant:
Signature:
Date:
111712019 10:55 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3.
1
i
4. Number of bedrooms
4.
2
5. is
this a worst case? (yes/no)
5.
No
6. Conditioned floor area (sq. ft.)
6.
1832
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.620
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.260
c) Area
7c.
263.7
8. Skylights
a) U-factor:(weighted average)
Be.
NA
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
c) Concrete, raised (R-value)
9c.
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
10A1.
2. Masonry (Insulation R-value)
10A2.
4.0
B. Adjacent:
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10B2.
13. Cooling system:
Capacity 36.0
a) Split system
SEER 16.0
b) Single package
SEER
c) Ground/water source
SEERICOP
d) Room unit/PTAC
EER
e) Other
14. Heating system: Capacity 24.8
a) Split system heat pump HSPF
b) Single package heat pump HSPF
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.90
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
f) Heat recovery unit HeatRec%
g) Other
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level a) Ceiling fans
a) Under attic 11a. 30.0 b) Cross ventilation No
b) Single assembly 11b. c) Whole house fan No
c) Knee walls/skylight walls 11c. d) Multizone cooling credit
d) Radiant barrier installed 11d. No e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has cot
saving features which will be li
display card will be completed
Builder
Address of New Home:
with the Florida Building Cade, Energy Conservation, through the above energy
d (or exceeded) in this home before final inspection. Otherwise, a new EPL
on installed code compliant features.
Date: //I ttl�I I e-J�
City/FL Zip: FORT PIERCE, FL 34951
1/17/2019 10:55:42 AM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1