HomeMy WebLinkAboutCONCRETE PADGENERATOR PAD THICKNESS AMERICAST GENERATOR CONCRETE PAD - (OWGRADE APPLICATIONS ONLY) AMERICAST •MADB INA1M0110A1• HVHZ OR NON-HVHZ RISK EXPOSURE EXP RISK EXPOSURE EXP RISK EXPOSURE EXP COUNTY I C D II C I D I III,IV I C I D P. BEACH 15O MPH 30.44 PSf 36.94 PSf 170 MPH 39.09 Psf 47.44 Psf 180 MPH 43.83 Psf 53.19 Psf BROWARD 156 MPH 32.92 Psf 39.95 Psf 170 MPH 39.09 Psf 47.44 Psf 180 MPH 43.83 Psf 53.19 Psf MIAMI-DADE 165 MPH 36.83 Psf A-- Psf 175 MPH 41.43 Psf 150.28 Psf 1186 MPH 146.80 Psf 156.80 Psf ISOMETRIC VIEW PAD DIMENSIONS: CONCRETE PAD GENEMTOR GENERATOR UNIT BY o I SEPARATE SUBMITTAL (SEE SCHEDULE FOR ;M I MINIMUM WEIGHT REQUIRED) 54"LENGTH PLAN VIEW CONCRETE PAD ROAD MESH ASTERFIBER 3- MIN MACI00 1- 14" MIN }-32" WIDTH -- GENERATOR TABLE: CAPACITY WIDTH LENGTH HEIGHT WEIGHT ALLOWABLE PRESSURE COMMENTS 5871 & 005883 SO KW 25.00" 48.00" 29.00 " 3871bs 41.43 Psf EXP C 175 MPH & D 156 MPH 5872&005884 14 KW 25.00" 48.OD" 29.00" 43 Ib 9 s 47.44Pf s59, DIP C 186 MPH &D 156 MPH NBRANDD&MODEL 6461, 6462 16 KW 25.00" 48.00" 29.00" 5131bs 47.44 Psf 6721 16 KW 25.00" 48.OD" 29.00" 448 lbs 47.44 Psf 5873&005885 17 KW 25.00" 48.00" 29.00" 4551bs 47.44 Psf 5874&005886 17 KW 25.00" 48.00" 29.00" 421 Its 47.44 Psf Generac 005875 & 005887 20 KW 25.00" 48.00" 29.00" 4511bs 47.44 Psf Generac 006729 & 006730 20 KW 25.00" 48.00" 29.00" 516 HIS 47.44 Psf Generac 006551&0065S2 22 KW 25.00" 48.00" 29.00" 5261bs 47.44 Psf Kohler 14RE5&20RE5 14-20 KW 26.00" 48.OD" 29.00" 500 HIS 47.M Psf GE 40323GE & 40324GE 13 KW 35.00" 39.40" 39.00" 540 HIS 39.D9 Psf EXP C 170 MPH &D 156 MPH BE 04038215KW 15 KW 33.00" 48.00" 30.50" 4841bs 43.83 PSf EXP C 180 MPH & D 156 MPH GE 04037817KW 17 KW 33.00" 49.00" 30.50 " 484115 43.83 PSI GE 40330GE & 40331GE 20 KW 33.00" 49.00" 30.50" 6001bs 43.83 Psf Briggs& Stratton D40243-0 10 KW 31.00" 32.00" 34.00" 4301bs 43.83 Psf Briggs & Stratton D40302.2 12 KW 33.75 " 50.00" 31.60 " 507 HIS 41.43 Psf DIP C 175 MPH & D 156 MPH Briggs & Stratton 040303-1 15 KW 33.75 " 49.00 " 31.60 " 562 HIS 43.83 Psf DIP C 180 MPH & D 156 MPH Briggs & Stratton 0403044 18 KW 33.75 " 49.00 " 31.60 " 568 HIS 44.00 Psf Briggs & Stratton 040305-1 20 KW 33.75" 49.00" 31.60" 5701bs 44.00 Psf Generac 7035,7036, 7037 16 KW MOB" 48.00" 29.00" 406 HIS 47.44 PSI EXP C 166 MPH & 0156 MPH Generac 007038 & 007039 20 KW 25.00 " 48.00 " 29.00 " 4481bs 47.44 Psf Generac OD7042& 7041 22 KW 25.00" 48.00" 29.00" 4661bs 47.44 PSI GENERATOR MOUNTING CONFIGURATION: GENERATOR ATTACHMENT BASE OR SIMPSON A24 ANGLE BRACE W/ (4) s10 SS 316 SELF -DRILLING € SCREWS TO GENERATOR (SEE GENERATOR SPECS), GENERATOR U, (SEE CONCRETE PAD W SCHEDULE FOR DIMENSIONS & WEIGHT REQUIRED) 4" I n I n i----54" LENGTH - i SIDE VIEW FRONT VIEW GENERATOR ANCHOR TO PAD SCHEDULE: SUBSTRATE DESCRIPTION CONCRETE: (2)-3/8'0 MEN HD (6000 PSI OR EQUIVALENT, MIN.) 2-3/4" FULL EMBED 0 CONCRETE, 3' MIN EDGE DISTANCE, 6' MIN. SPACING TO ANY ADJACENT ANCHOR. NOTES: 1. ANCHOR QUANTITY PER LONG SIDE 2. EMBEDMENT AND EDGE DISTANCE EXCLUDES FINISHES, IF APPLICABLE. 3. ENSURE MINIMUM EDGE DISTANCE AS NOTED IN ANCHOR SCHEDULE. 4. ENSURE MINIMUM SPACING TO ANY ADJACENT ANCHORS. S. FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS TO INSTALL ANCHORS. GENERATOR ATTACHMENT BASE, VARIES WITH MODEL SEE GENERATOR SPECS V SIMPSON TITEN HD, SEE ANCHOR SCHEDULE 2'x3'x3/e" GALV. STEEL - WASHER RUBBER VIBRATION PAD - %' THICK GALVANIZED WASHER& RUBBER VIBRATION PAD Z CONCRETE PAD - iv 6,000 PSI n , LIGHTWEIGHT CONCRETE PAD X CONCRETE MIX 6,000 PSI-1III- LIGHTWEIGHT \ MASTERFIBER MAC 100 /11 a CONCRETE MIX & ROAD MESH }�2 NOTES: FOAM CORE 1. Y DISTANCE DEPEND ON GENERATOR BASE LENGTH, NO LESS THAN 2". 2. X DISTANCE 3' FROM UNIT EDGE TO CLIP. 3. Z DISTANCE DEPEND ON GENERATOR BASE WIDTH, NO LESS THAN ANCHOR REQUIREMENTS FRANK L B 0, P.E. T PES0046549 RECEIVED 03/ 018 JAN 7GORDON 6OERFC. G .I>IFA6 BB4,1 ,O M. DI STO, P.E. 2328 NOTICE: IF THIS SHEET DOES ST: Lucie County, Permitting - = NOT CONTAIN AN ORIGINAL SIGNATURE Is ENGINEER SEAL: IF THERE IS A DIGITAL SIGNATURE ON SHEET 1, THIS SHEET IS PART OF A DIGITALLY SCANNED SIGNED FRE, SHALL ORMAT,&RMAININTE IN DIGITAL FORMAT, & PRINTED COPIES DOCUMENT V SIHES CONSIDEREDSIGNED ARE NOTED. THERESIGNEO L/� pA.,j _rI_EtT - IF S NO ANDSEALED.SIGN,IFTHE NSHEE OR SHEETTDREON SHEETI WIND DESIGN REQ LIT9 IYUJ�pt OR THIS SHEET DOES NOT THIS MAIN AN ENGINEER'S ORIGINAL SIGNATURE 6 SEAL, (BASED ON ASCE 7-10 & FLORIDA BUILDING CODE SIXTH ED ON (2017)) TMIs sxEET Is A COPY DAFT. AT -GRADE SIGN METHOD //fIII ULTIMATE DESIGN WIND SPEED VDIt = 186 mph NOMINAL DESIGN WIND SPEED Vasd = 144 mph RISK CATEGORY = III INTERNAL PRESSURE COEF = N/A �� ® W M "+Y i ff''L" EXPOSURE CATEGORY = D WIND DIRECTIONALITY FACTOR Kd= LI- m 300 U. Ea u 0.85 W Vt2 UIm ENCLOSURE CATEGORY = N/A HEIGHT H = AT GROUND W 1w,J, w UJ IA W GUST EFFECT FACTOR = 0.85 PRESSURE AT HEIGHT H qh = 77.56 Ib/ft2 O S m M a F Z � UI U S� FORCE COEFFICIENT Cf a 1.44 � W 4 K Q (a o w M uo WIND PRESSURE: aL m o P= qh G Cf = 56.80 1b/ft2 (ASD) ZX Of r4 '�m' w W U W W O_, �Z W GENERAL NOTESILI U PO.. 3 LL d=w 1. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE O W di to SIXTH EDITION (2D17). n 2. REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED UNDER SEPARATE CERTIFICATION ON A JOB -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. N O N SITE -SPECIFIC LOAD REQUIREMENTS AS DETERMINED IN ACCORDANCE WITH m Q Z THE APPLICABLE BUILDING CODE SHALL BE LESS THAN OR EQUAL TO THE O d O DESIGN PRESSURE'ASD' CAPACITY VALUES LISTED HEREIN FOR ANY lJL E ASSEMBLY AS SHOWN. LL TO 3. DIMENSIONS AND WEIGHT OF UNITS SHACONFORM SPECIFICATIONS U) G DO O Y Z w STATED HEREIN. 4. UNITS MUST BE CENTERED ON PAD WITH OPPOSITE SIDES HAVING EQUAL LL Q O On CLEARANCE. A MINIMUM DISTANCE FROM UNITTO PAD EDGE IS SPECIFIED. U I m F S. CALCULATIONS MADE USING LIGHTWEIGHT CONCRETE 125 PCF Us U ')'� LLI A'J W 6. THE AREA UNDER CONCERETE SLAB ON GROUND SHALL HAVE ALL ICI f w A w DO = O n LD VEGETATION, STUMPS, ROOTS, AND FOREIGN MATERIALS REMOVED PRIOR � _1a O TO INSTALLATION ON COMPACTED SOIL AS VERIFIED BY OTHERS. 1 F- ry W n G Z U7. 2 (7 RESISTANCE TO SLIDING OFTHE PAD ON THE GROUND IS NOT PART OF THIS K m O J Z DOCUMENT AS SOIL CHARACfERI5ITC5 AND PAD PLACEMENT VARIES. C G M LL v 8. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY Y OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) Q W SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. p 9. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS L9 SHOWNONLY. USEOFTHISSPECIFICATIONBYCONTRACTOR,e al. a INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST &DAMAGES O INCLUDING LEGAL FEES & AFFILIATE FEES RESULTING FROM MATERIAL LL FABRICATION, SYSTEM ERECNON, CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED MR BY LOCAL, STATE, & FEDERAL CODES &FROM DEVIATIONS OFTHIS PLAN. O 10. WATER -TIGHTNESS OF EXISTING FINISHES SHALL BE THE PULL o $ o OS RESPONSIBILITY OF THE INSTALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE MR ANY O u u y 0 000 WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS O u WATER -TIGHTNESS SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING-W0 0 S S S zZ uo CONTACTOR. ' B O9 (gg3 11. THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE $ ffW3 ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE MR THE 3 INTEGRITY OF ALL SUPPORTING SURFACES TO THI5 DESIGN WHICH SHALL BE COORDINATED BY THE PERMITTING CONTACTOR. 2 x 12. THIS DOCUMENT IS GENERIC AND DOES NOT PERTAIN TO ANY SPECIFIC w n Sqo PROJECT SITE. INFORMATION CONTAINED HEREIN IS BASED ON S m CONTACTOR -SUPPLIED DATA AND MEASUREMENTS. ENGINEERING EXPRESS Q y ad SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS E OR INACCURATE DATA OR MEASUREMENTS. DIMENSIONS ARE SHOWN TO LC e O 3 ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY VARY o ' SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN. WPOUGM ExGIxEEaxG FxvREssl 1 �_ I . l L� 1 WORK SHALL BE FIELD VERIFIED BY OTHERS PRIOR TO CONSTRUCTION. ENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE SCALE: NTS UNLESS NOTES INFORMATION PRIOR TO MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS. ALTERATIONS OR OF� ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. 13. EXPRESSLYINTENDPROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS OR AFFIRMATIONS ARE INTENDED.