Loading...
HomeMy WebLinkAboutCERTIFICATE - DESIGN LOAD COMPLIANCEPlanning & Development Services Departure Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982— (772) Certification for Design Load Compliance Project Name: Stalhut Residence Project Address: 4795 Jorgensen Road Fort Pierce, FL 34981 J N b 7 23 Permit #: Occupancy Type: R-3 Construction Type: V-B �04' ,�AA� INSTRUCTIONS FOR USE: 61t �[/O��y'v�® • This certification must be completed, signed, and sealed by the design professional of record. Cot/ • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: ny o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Residential Code Sixth Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category:_I X II _III_IV Exposure Category:_B X C _D 4. Design Wind Velocity 160 mph ASD X LRFD End Zone Width: 6 ft 5. Mean Roof Height 18 ft Roof Pitch: 6 :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: +40 Zone 2: -79 Zone 3: -103 Zone 4: -36 Zone 5: 45 Garage: n/a 7. Design Loads: Floor:60 PSF Roof/Dead: PSF Roof/Live: Balcony: PSF Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes NotApplicable Explain Why Not: 10. Design Soil Bearing Pressure: 1,800 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: ` ,� I certify that, to the best of my knowledge and belief, the attached plans & s eci I `� sl o comply with the applicable structural portions of the building codes currentrEOR rGO&WI A E County. I also certify that structural elements depicted on these plans provid979VItUEc forces specified: finnystem WSernm s Oft Terence Schli#�-0 Signature, Date, and Seal Revised 12/6712018' Terence Schlitt, FL PE 81238 CA 32295 ®®CC Print Name Cert # & Co. Cert Auth. TE Schlitt Engineering 1555 Indian River Blvd Suite B-145 Vero Beach, FL 32960 Company Name & Address