HomeMy WebLinkAboutSOIL NUCLEAR GAUGEle10/ 6It,
0I
a
Pon St. Lucie
FBPE CA C 49M
Soil Nuclear Gauge
Report Date., 8/5/2019
Test Method: ASTM D 6938
Client:
Larry Neese, LLC
488 S. Market Road
Fort Pierce, FL 34982
Project:
17-1032.00
Larry Neese, LLC Master Proposal for Various
Locations
607 W Commodity Cove SCANNED
Pon St. Lucie, FL 34906
Phone: 772-924-35751 F. M-924.3580 BY
Test Results
oufltV
Test#
Retest
Of
Test
Date
ProctorlD
Method
Soil
Classification
Optimum
Moisture
%)
' Maximum
Dry Density
(Pen
In Place
Moisture
N
In Place
Dry Density
(p
Probe
Depth
in
Percent
Compaction
Min/Max
Comp.
%
Remark
7
7117119
P-3
N/A
11.5
104.6
9.1
101.9
12
97
951 105
Pass
8
7/17119
P-3
N/A
11.5
104.6
9.0
'102.6
12
98
951 105
Pass
9
7117119
P-3
NIA
11.5
104.6
9.8
102.0
12
98
951105
Pass
10
7117119
P-3
NIA
11.5
104.6
9.5
103.7
12
99
951 105
Pass
11
7/17119
P-3
NIA
11.5
104.6
9.9
102.4
12
98
95/ 105
Pass
121
7117'19
P-3
NIA
17.5
104.E
9.3
103.0
12
98
95/ 105
Pass
13
7/17119
P-3
NIA
11.5
104.6
10.1
102.7
12
98
95 / 105
Pass
Test Information
_
Test #
Test Location
Elevation
Reference
Gauge
Make / Model / SN / Calibrated
Field Technician
7
Below Bottom of Footing: 4795 Jorgensen Rd., Ft Pierce, See map location #1
D-1'
Troxler /T3440 127974 /
Liverman, Robert
8
Below Bottom of Fooling: 4795 Jorgensen Rd„ Ft Pierce, See map location #2
0-1'
Troxler 1 T34401279741
Liverman, Robert
9
Below Bottom of Footing: 4795 Jorgensen Rd., Ft Pierce, See map location #3
D-1'
Troxler / T3440 / 27974 /
Livemlan, Robert
10
Below Bottom of Footing: 4795 Jorgensen Rd., Ft Pierre, See map location #4
0.1'
Troxler/ T3440 / 27974 /
Liverman, Robert
11
Below Bottom of Footing: 4795 Jorgensen Rd., Ft Pierce, See map location #5
0-1'
Troxler/ T3440 / 27974/
Liverman, Robert
12
Below Bottom of Footing: 4795 Jorgensen Rd., Ft Pierce, See map location #6
0-1'
Troxler /T3440 / 27974 /
Liverman, Robert
13
Below Bottom of Footing: 4795 Jorgensen Rd., Ft Pierce, See map location #7
0-1'
Troxter /T3440 / 279741
Livernian, Robert
Remarks
I Comments
Pass: Tests results comply with specifications
Tests am'Direct Transmission (Method A) unless probe depth Is noted as
'Backscatter. Gauge calibration data on file with the testing agency.
AUG 0 9 2019
ST Lucle County
Test Reports shall not be reproduced, except In full, without the written approval of GFA International Inc.
.
.• GtGENyF'•., �
No 63 8
-�+ ✓ 08/05/�019
90 {tent .E.
PneflTUrg'9@er #'
S ttoi(?1oP•. •' G�\�.
AL 1� \\•
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Page 1 of 1