Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
GENERAC PAPERWORK
16/20/22 kW d1 True Power" Electrical Technology ® Two Line LCD Multilingual Digital Evolution' Controller (English/Spanish/ French/Portuguese) ® Two Transfer Switch Options Available: 1Go Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 5 for Details. ® Electronic Governor . =RECEIVED GENERAC SGUAR®SAN° SERIES �r ,y Residential Standby Generators ij, � �, � • Air -fooled has Engine ® Standard WI-Fl- Remote Monitoring ® System Status & Maintenance Interval LED Indicators ® Sound Attenuated Enclosure A Flexible Fuel Line Connector • Direct -To -Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation • 5 Year Limited Warranty Standby Power Rating Models G007036-1, G007037-1 (Aluminum - Bisque) -16 kW 60 Hz Model G007035-1 (Aluminum - Bisque) -16 kW 60 Hz ST.LUCIE COUNWdels G007039-1, G007038-1 (Aluminum - Bisque) -20 kW 60 Hz PLAN REVIE%odels G007043-2, G007042-2 (Aluminum - Bisque) - 22 kW 60 Hz BLDG: DATE: ����7,p p—,fir—yyN� EL�Ni1l� DATE: PLUMB: DATE: MECH: DATE: • Listed and Labeled by the Southwest Research Institute allowing Installation as close as 18" (457 mm) to a structure.* *Must be located away from doors, windows, and fresh air intakes and in accordance with local codes. hto=llassets.swA.oTrgllib2ry/Di'mctoryOfUstedPmducisl Conseucdonlndusby 973 DOC 204_13204-01-01 Rev9.pdf FEATURES C V0 DS QUIET-TEST.-u de LISTED Note: CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are UL cadged In the USA any. O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generads O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: success in providing the most reliable generators possible. Genera c's G-Force engine This state -of -ahead power maximizing regulation system is standard on lineup offers added peace of mind and reliability for when you need it the most. The all Geneac models. It provides optimized FAST RESPONSE to changing G-Force series engines are purpose built and designed to handle the rigors of load conditions and MAXIMUM MOTOR STARTING CAPABILITY by extended ran times In high temperatures and extreme operating conditions. electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1 %. O TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer form produce less than 5% Total Harmonic Distortion for utility quality power. This allows network provides parts and service know-how for the entire unit, from the confident operation of sensitive electronic equipment and micro -chip based appliances, engine In the smallest electronic component. such as variable speed HVAC systems. O TEST CHITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are ✓ PROTOTYPE TESTED ✓ NEMAMGI.22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY confidence is that the GENERAC product line Includes its own transfer systems and controls for total system compatibility. O MOBILE LINKTM REMOTE MONITORING: FREE with every Guardian Series Home standby generator. Allows you to monitor the status of your generator from anywhere in the _ GENERAC 'a. g"- c _ Wa world using a smartphone, tablet or PC. Frilly access information such as the current� P R O M I S E q®f �* °"`� operating status and maintenance alerts. Connect your account to your authorized service dealer for fast, blandly and proactive service. With Mobile Link, you are taken are of before the next power outage. Coup`Yhe 16/20/22 W featu s and benefits Engine ® GenaracG-Force design Maximizes engine "breathing"for Increased fuel off lciency. Plateau honed cylinderwalisand plasma molyrings helps the engine run cooler, reducing oil consumption resulting in longer engine life. O "Spiny-lok" cast Iron cylinder walls Rigid construction and added durability provide long engine life. ® Electronic IgnitioNsparkadvance These features combine to assure smooth, quick starting every time. ® Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur- Ing up to a 2 year/200 hour oil change Interval. m Low oil pressure shutdown system Shutdown protection prevents cifastrophic engine damage due to low oil. ® High temperature shutdown Prevents damage due to overheating. Generator ® Revolving field Allows fora smaller, light weight unit that operates 25% more efficiently than arevolving armature generator. o Skewed stator Produces a smooth output wavefarm for compatibility with electronic equipment. ® Displaced phase excitation Maximizes motor starting capability. A Automatic voltage regulation Regulates the output voltage to±l%prevents damaging voltage spikes. ® UL2200listed For your safety. Trarar7ar S%vitch (U applicable) ® Fully automatic Transfers your vital electrical loads to the energized source of power. m NEMA 3R Can be Installed Inside or outside for maximum flexibility. o Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. Evolution"" Controls s Auto/ManuaVCg Illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication In any condition. e Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. o Sealed, raised buttons Smooth, weather -resistant user Interface for programming and operations. ® Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80%pick-up, of standard voltage. * Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. ® Utility Interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. 0 Engine warm-up Ensures engine Is ready to assume the load, setpolnt approximately 5 seconds. ® Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. ® Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. ® Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. 0 Main line circuit breaker Protects generator from overload. ® Electronic governor Maintains constant 60 Hz frequency. Unit s SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Elecbostat- Icaliy applied textured epoxy paint for added darabli ty. A Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. o Small, compact, attractive Makes for an easy, eye appealing Installation, as close as 1811 away from a building. Installation System 0 1 it (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. a Direct -to -did composite mounting pad Complex lattice design prevents settling or sinking of the generator system. of Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. 16/20/22 kW specifications Generator Model 0007035-0, G007036.0, 0007038.0. G007039.0 8097042.1, 8007043.1 0907037.0 (16 kW) (20 kW) (22 kW) Rated Maximum ContinuousPower Cipacily(LP) 16,000Watle 20,000 Us- 24000 Rated Maximum Continuous Power Capacity (NO) 16,000 watts- 18,000 Watts' 19,500 R,aled.Vollage. 240 240 240 Rated Maximum Continuous Load Current-240 Volts(LP/NG) 66.6/66.6 83.3175 91.6181.3 Total Harindilo Mention Less than 5% Less than 5% Less than 5% Main Line Circuit Breaker 70 Amp 100 Amp 100Amp Phase. . 1 1 1 Number of Rotor Poles 2 2 2 Rated AC. Frequency 60 Hz 60 Hz 60Hz Power Factar - 1.0 1.0 1.0 Rotary, Requirement (not included) 12 Volts, Group 26B 540 CCA Minimum or Group 35AGM 650 CCA Minimum Unit Weight (Inviad 408/186 4481203 466/211 Dimensions (L'xWx III iNmm 48825 x 2911218 x 638 x 732 Sound onlput in dB(A)at 23 it(7m) wiin generator operating at normal load" 66 66 67 Sound aUlan t In off (A) a[ 23 It(7 m) with generator 1n Dula I-Test"'low-speed exercise mode'^ 58 58 58 Exercise duration — _ _ _ 5 min 5 min 5 min Engine Type of Engine GENERAC G-Force 1000 Series Number of Cylinders 2 2 2 Displacement 999 cc 999 cc 999 cc Cylinder Block Aluminum w/ Cast Iran Sleeve WMArrangement Overhead Valve Overhead Valve Overhead Valve Ignition System Solid-state w/Magneto Solid-state w/Magneto Solid -slate w/Magneto Governor System Electronic Electronic Electronic Compression Relic 9.5:1 9.5:1 9.5:1 Starter 12 Vdc 12Vdc 12 Vdc Oil Capaclry Including Filter - Appm)L 1.9 gV1.8 L Approx. 1.9 gV1.8 L Approx. 1.9 gV1.8 L Operating rpm 3,600 3.600 3,600 Fuel Consumption ' Natural Gas ffa/hr (mp/hr) 1/2 Load 218 (6:17) 204 (5.78) 228 (6.46) Full Load 309 (8.75) 301 (8.52) 327 (9.26) Liquid Propane fts/hr OWN I* 112 Load 91.6 (2.52) (9.53) 86 (2.37)18.99) 92 (2.53)19.57] Full Load 106.8 (2.94) [11.11) 129.6 (3,56)113A8] 142 (3.90) [14.771 Note: Fuel pipe must6estz.'d,t unload. Requimdf Vyressuretogenemtor fuel Inlet at all land ranges -3.5-7°water coluran(7-13mmmercury) for natural gas, l0-12°water for IPgas. For Blu column (19-22 arm mercury) . content mulllply IlaPorx 2500 (tP} or IN/hrx 1000 (NG). For Meoaloule content multiply me@rx 93.15 (LP) or m=/nrx 37 26 (NG) 2-11ne Plain Text Multilingual LCD Display Made Bultons:Aula Manual off . Ready to Ru wMaintenance Messages Engine Run Hours Indloa0on Programmable start delay between 2-1500 seconds 11111ilyVollegp,Losa4leturn to,116lityA'dlustable (Brownout Setting) Future Set Capable Exerciser/Exercise Set Error Warning RnNAlann'Malntenance Logs' Engine Sian Sequence Stoner Lock -out Smad Battery Charger Charger,FaulVMissing At Warning Low Battery/Battery Problem Protection and Battery Condition Indication A'alomatic VolMys Regulation with Overand Under Voltage Protection Under-Frequency/Overload/Stepper Oveicurrent Protection Safety Fused( Fuse Problem Protection Automatic Law Oil Pressure/Hlgh Oil Temperature Shutdown OvercanWOwwspeed (@ 72 Hi)/rpm Sense Loss Shutdown High Engine Temperature Shutdown Internal Fi dulncorrecl *Ing Prolecliole Common Edernal Fault Capablllry Field Opgiedablel Firmware Simple user interface for ease of operation. Automatic Start on Ofilily failure. 7 day exerciser. Start with starter control, unit slays on. If ulility Mils, transfer to load takes place. Stops unit. Power is removed. Cannot and charger still operate. Standard Standard Standard (programmable by dealer only) From140-171 V/190-216V Standard 50 Giants Each Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration). Starter canal re-engage until sec after engine has stopped. Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard N( (gri[tn ffil Description GENERAL® Service and non -Service rated Automatic Smart Transfer Switches 100 - 400 Amps, Single Phase c@ us LISTED 'GnL only applies to non -service rated switches Generac Automatic Transfer Switches are designed for use with single phase generators that utilize an Evolution'0 or Nexus"' Controller. The 100, 200, and 400 amp open transition switches are available in single phase in both service equipment rated and non -service equipment rated configurations. The 150 and 300 amp open transition switches are only available in a service rated equipment configuration. Standard Features Service rated (RXSW) Generac Automatic Transfer Switches are housed in an aluminum NEMA/UL Type 3R enclosure`, with electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for years of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All switches are covered by a 5 year limited warranty. Non -service rated (RXSC) switches are housed in a steel enclosure. DPM Technology Through the use of digital power technology (DPM), these switches have the capability to manage up to 4 individual HVAC (24 VAC controlled) loads with no additional hardware. When used in tandem with Smart Management Modules, up to 8 more loads can be managed as well, providing the most installation efficient power management options available. "/1rso 4 2(00800 l 100-400 Amps, Single Phase Automatic Smart Transfer Switches Functions All liming and sensing functions originate in the generator controller The transfer switch can be operated manually without power applied. "When used in conjunction with units utilizing Evolution'" controls "Adjustable via the controller Specifications Model RXSC100A3 RXSW100A3 RXSW150A3 MSC20OA3 RXSW200A3 RXSW300A3 RXSC40OA3 RXSW400A3 Amps 100 100 150 200 200 300 400 400 Voltage 120/240, I 120/240,1e 120/240, to 120/240, to 120/240, 1e 120/240, to 120/240, to 120/240,10 Load Transition Type (Automatic) OpenTmnsition Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Service Rated Enclosure Type NEMA/UL 3n NEMAAIL 311 NEMA/UL 311 NEMA/UL3R NEMA/UL311 NEMA/UL 311 NEMA/UL 3R NEMA/UL 3R UL Rating UUCUL UL UL UUCUL UL UL UUCUL UL Withstand Rating (Amps) 10,000 10.000 22.000 10.000 22,000 22,000 22,000 22.000 Lug Range 110-#14 250 MGM-#6 600 MGM -#4 or 1/0 - 250 MGM Dimensions Model RXSC100A3 RXSW100A3 RXSW150A3 PLXSC200AS HXSW200AS HXSW300A3 RXSC400A3 RXSW4C0A3 Height H1 17.24/437.9 17.24/437.9 26.75/679.4 17.24/437.9 26.75/679.4 42,91/1089.9 31.25p93.8 42.91/1089.9 (In1mm) H2 20/508 20/508 30/762 20/508 30/762 48/1219.2 36/914.4 40/1219.2 M W Ifth 125/317.5 125/317.5 10.5/266.7 12.5/317.5 10.5/266.7 16.69/423.9 19.181487.2 16.69/423.9 On✓mm) W2 14.6/370.8 14.6/370.8 13.51342.9 14.6/370.8 13.5/3429 21.82/554.2 24/809.6 21.871554.2 Depth (Inlmm) 7.09/180.1 7.091180.1 6.31160.1 7.09A80.1 6.3/160.1 10.06/255.5 10.061255.5 10.06/255.5 Welght(lbsAilos) 20/9.07 22.5po.21 39/17.69 20/9.07 39/17.69 140/63.5 133160.83 140/63.5 OFPfH GENERAC' Generac Power Systems, Inc. • S45 W29290 HWY..50, Waukesha, W153189 • generac.com ' @2817 Geneme Power Systems, Inc. All dghls reserved. All specifications are subject to change without notice. retain 10000013459-A 04/24/17 16/20/22 kW Modeh# �',: Peoduel. �esceip9iop. The WI-Fl enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Mon- GOD7005-D Wi-FI LP Fuel Level Monitor timing the LPtank's fuel level Is an Important step in making sure your generator is ready to ran during an unexpected power failure. Status alerts are available through a free application to notify when your LP tank Is in need of a refill. Generac's Mobile Link allows you to check the status of your generatorfrom anywhere that you have ac- 6006468 4 Mobile Link " cess to an Internet connection from a PC orwith any smart device, You will even be notified via a -mall or text message when a change in the generator's status occurs, Available In the U.S. only. 6005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 25R wet cell battery for use with all air-cooled standby product (excluding PowerPact®). G007101-0 'Battery Pad Warmer Thapadwarmerrestsunderthebattery.RecommendedforuseIfthetemperatureregularlyfallsbelow0°F. (Not necessary for use with AGM -style batteries). G007102-0 OIIWarmer Oil warmer slips directly overthe oil filter. Recommended for use if the temperature regularly falls below 0°F. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to look out a single large electrical load Contact Kit you may not need, Not compatible with 50 amp pre -wired switches. Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a G007027-0 -Bisque (Standard on 22 kM sleek, contoured appearance as well as offering protection from rodents and Insects by covering the lifting holes located in the base. If the generator enclosure Is scratched or damaged, It is important to touch-up the paint to protect from • G005703-0 -Bisque Paint KO future corrosion. The paint kit Includes the necessary paint to properly maintain or touch-up a generator enclosure. 'G006485.0 Scheduled Maintenance Kit Genemc's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on aGenerac automatic standby generator. ' G006873.0 .Smart Management Module Smart Management Modules are used in conjunction with the Automatic Transfer switch to Increase Its (50 Amps) powermanagement capabilities. It provides additional power management flexibility notfound in any other power management system. I.EFl`Gonwm dimensions & LIM Dim enslons shown are approximate. Refer to Installation manwl for met Rme osr= DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES, .NTVIM GE O E— RMCI' Generac Power Systems, Inc. - 845 W29290 HWY. 59, Waukesha, WI 53189 > generac.com C2017 Generac Power systems, MG. All 49% reselved.All specincagons are softest to change WrUlDlrtnogce. Part No: 10000000194.FSIM7 Smart filaaagement Model (ROM73.0 aus — 6tsiEU DESCRIPTION Generac's Smart Power Management System is designed to optfmfze the performance of a standby generator. The system can consist of up to 8lndfviduel Smart Management Modules (SMM). Unlike other load management systems that depend on another control device, the SMM modules are actually self - aware and operate autonomously. Frequency Is the true measure of generator engine performance and does no( need to factor In increased ambient temperatures, elevation changes or generator fuel type. The modules monitor the frequency (Hz) of the power being produced by Ganerec's standby generators and If It falls below a certain threshold, the module will automatioally follow a power management algorithm to ensure that the generator Is not overloaded. The modules can be set to a load priority between 1-8 or be set in a lock out only mode for too d5 that just Sfmpry de not RBBd f0 fUR in an outage, therefore reducing the necessary Size of the generator for a more cost effective solution. _....... ................................. ................................,,,...,.,,,.............,...,............................................... Potes._...._..........................................................................................I......, ........_.6.5 WalksAMPS . .......................................................w....................,.......... 2 KinducuveAm...................................................................50 Locked RatorAm .................In 50 - .......240eo 240V Enclosure Baling.............................._............................,.,,....... ............... ..,..,...,............. . Yes .............._.........._.._.. .. _. =vAn ILlmo`:Iti I i TIll!,llfl E',C Igf• l'V f);lil[r`151@fly' � , 11trilel W1 0 0 OMM Controls (located behind the cover of the module) 1 LED ON. LOAD SOILME➢ FR{ORLOOKOUT LEDHASDiS=LOADSDFd =➢N E MMErrATOR LeeFcasNas=aOMwrACamli LEDFUSDSS=OENLOADLO➢MUr a Y LPD DOMa➢OrEP001En ® ® O O T TES T ➢1SAELEO MLI Pdodlymalp— sets Inadule priody, Laded SAO(B)— PreverdsloadfromoperelingwheasystemIsoperatingundergeneratorpowet Test Eden M— Dlsahles ooniaoloroulPN for a speclged tlme. LED (0)_ ProNdesm"uleslelusv/nh sasyvlervingih'0 hthe va mal vimving vdndmv lacabd In lha upper fight comer or the motlWe, Generac Power Systems, Inc. o 845 W29290 HWY. 59, Waukesha, W153189 a generae,com (32OfSGenmao PavmrSystems, Inc. All ndbs reserved. AS speeifleaao�m am subjeotrocaanpe vnlhootnmtce. SueeEn OL750bC O3/f0}m Site Selection and Preparation — . — — 5it(1.52m) 110 J 5 it (1.52 m) i I ® ¢ aft © , (0,91 m)� a 3 it (081 m) To dl B P Fgure 24, lrrsta/latfar Clearances to Description comments A Top of generator — B Front and end clearance Mnlmum oleardistances cannot Include shrubs, bushes, or hens. C Rear elearanre. 9a e, (4 7 em minlmu,n oleamnoe per NFPA testing, fabeting, and Meting, Unless State or local codes dictate otherwise. D Windows and openings No operable windows, doors, or openings In the wall are permitted within 5 It (1.52 m) from airy point of the generefor. E Existing wall Cna-heUr fire rated wafts allow closer placement of the generator set. Confirm before Instatiafton. F Removable fence Removable fence panels forservittinng cannot be placed less than 3 ft (0.91 m) In front of the generator. G Overhead clearance 6 If (1.52 m) minimum distance from any structure, overhang, orprojections from the wall, DC NOT instaff under wooden decks orstructmes unless this distance is maintained. Installation Guidelines For60 Hz Air -Cooled Generators 11 Site Selection and Preparation 9'J Install the generator set, in its protective enclosure outdoors where adequate cooling and ventilating air is always available (Firtrre— s-1), Consider these factors: ° The Installation of the generator must comply strictly with ICC iFGC, NFPA 37, NFPA 54, NFPA 58, and NFPA 70 standards. ° Install the unit where air inlet and outlet openings will not become obstructed by leaves, grass, snow, efc. if prevailing winds will cause blowing or drRing, consider using a windbreak to protect the unit. ` Install the generator on high ground where water ►sve►s will not rise and endanger it, This unit should not operate in or be subjected to standing water. ° Allow sufficient room on all sides of the generator for maintenance and servicing. This unit must be installed in accordance with any local, state, Or national godes for minimum distances from other structures. ° Clearance from the ends and front of the generator must be 3 if (0.91 m). This includes shrubs, bushes, and trees. Clearance from the back of the generator must be a minimum of 18 in (457 rum) Clearance at the top should be a minimum of 5 ft (1,52 m) from any structure, overhang, or projections from the wall. ° DO NOT install under wooden decks or structures unless there is at least 5 ft (1.52 m) of clearance above the generator install the unit where rain gutter down spouts, roof run off, landscape irrigation, water sprinklers, or A sump pump discharge does not flood the unit or spray the enclosure, including any air inlet or Outlet toA openings,m ° Install the unit where services wilt not be affected Be or obstructed, Including concealed, underground, a or covered services such as electrical, fuel, phone, exc air conditioning, or irrigation. This could affect and warranty coverage, ma man — The generator must be installed on a level sur. face. The generator must be level within a 0.5 In (13 mm) ail around. — The generator fs typically placed on pea gravel, compacted soil, crushed stone, or a concrete Pad. Check local codes to see what type is required. If a concrete pad is required, all appli. cable codes should be followed. Installation Guidelines for Stationary Air -Cooled Generators NFPA 37 is the The National Fire Protection Association's standard for the installation and use of stationary combustion engines, its requirements limit the spacing of an enclosed generator set from a structure or wall (Figure 3-1). NFPA $7, Section 4.1.4, Engines Located outdoors: Engines, and their weatherproof housings if provided, that are installed outdoors shall be [coated at least 5 $ (1,52 m) from openings in walls and at least 5 ft (1.52 m) from structures having combustible wails. A minimum separation shall not be required where the following conditions exist: 1 • The adjacent wall of the structure has a fire resistance rating of at least one hour. 2. The The enclosure is constructed of noncombustible materials and it has been demonstrated that a fire within the enclosure will not ignite combustible materials outside the enclosure. nnex A — Explanatory ivlaterial 4.1.4 (2) Means of demonstrating compliance are by sans of full scale fire test or by calculation procedures. cause of the limited spaces that are frequently vatlable for installation, it has become apparent that eption (2) would be beneficial for many residential commercial installations. Ulrich that In mind, the to run contracted with 8n independent testing Scale fire ° where strong prevailing winds blow from one enclosurebWill not hign tee combustible to rmate lad at the direction, face the generator air inlet openings to the enclosure, re the prevailing winds. outside install the generator as close as possible to the fuel NOTE. Southwest Research Institute testing approves supply to reduce the length of piping. REMEMBER F in (457 mm) installation minimum from structure THAT LAUDS OR CODES MAY REGULATE THE (Figure 3 v' C)• Southwest Research institute is s DISTANCE AND LOCATION. in the absence of 'Icnyaily recognized third Party local codes regarding placement or clearance, we testing and listing recommend following these guidelines: The cdterla was to determine the worst Case fire scenario — install the generator as close as possible to the within the generator and to determine the ignitability of transfer switch. REMEMBER THAT LAWS OR hems outside the engine enclosure at various distances. CODES MAY REGULATE THE Dig T r1N0E AND The enclosure is constructed of non cornnbust�bte LOCATION. matelots, and the results and conclusions from the r,k;dependent testing lab indicated that arty fire within the installation Guidelines For 60 HzAir•Cooled Generators