HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERG` Florida Department of JAN 0 4 2019 EFFICIENCY(, E FOR BUILDING CONSTRUCTION Lucie County; _-errn o�stness-and PnSfessional Regulation - Residential Performance Method Project Name: ROBYN FOSTER Builder Name: S(�,P1�I n1g® Street: 316 SHADY LANE Permit Office: City, State, Zip: PORT ST. LUCIE , FL, Permit Number. BY Owner: Jurisdiction; St. Lucie County Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing Addition 9. Wall Types(1648.0 sgft.) Insulation Area 2, Single family or multiple family Singlo-family a. Concrete Block - Extlnsui, Exterior R=4.1 1136,00 ft2 3. Number of units, if multiple family 1 b. Frame -Wood. Exterior R=13.0 320.00 ft2 ' c. Frame - Wood, Adjacent R=11.0 192.00 ft2 4. Number of BedroomdBedrms In Addition) 3(0) d• NIA R= ft2 5. Is this a worst case? No 10, Ceiling Types (1251.0 sgft.) 'Insulation Area a. Under Attie (Vented) R=30.0 1251.00 1`12 6. Conditioned floor area above gentle (ft2) 1251 b. N/A R- ft2 Conditioned floor area below grade(R2) 0 c• NIA R= ft2 11. Ducts R ft 7. Windows(214.0 sgft.) Description Area a. Sup: Attic, Rat: Attic, AH: Main 6 135 a. U-Factor: - Sgl, U=0.79 193.00 ft' SHGC: SHGC=0.45 b. U-Factor Sgl, I1=0.75 21.00 IF 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.45 a. Central Unit 28.2 SEER:16.00 c. U-Factor. NIA ft2 ' SHGC: 13. Heating systems kBtu/hr Efficiency d. N/A R2 a. Electric Strip Heat 27.0 COP:1.00 S SHGC: SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.450 14. Hot water systems - None required 8. Floor Types (1251.0 sqft.) . Insulation Area a' Cap: N/A a. Slab -On -Grade Edge Insulation R=0.0 1251.00 ft2 b. Conservation features EF: 0.000 b. NIA R-- ft2 c. N/A, R= ft2 15. Credits CF, Pstat Glass/Floor Area: 0.171 Total Proposed Modified Loads: 45.78 PASS Total Baseline Loads: 46.18 / 1 I hereby certify that the plans and specifications covered by Review of the plans and Sr1? this calculation are in compliance with the Florida Energy Code. specifications covered by this calculation indicates compliance with the Florida Energy Code. mr .:, ki p PREPA E B Before construction is completed DATE: this building will be Inspected for compliance with Section 653.908 _ I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. G,OD WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 1/2/2019 2:16 PM EnergyGaugeO USA Section.R405.4.1 Compliant Software Page 1 of 4 FORM R40572017 INPUT SUMMARY CHE CKUST REPORT PROJECT Title: I Building Type: ROBYN FOSTER Bedrooms: 3 User ' Address Type: Street Address owner Name: Conditioned Area: 1251 . Lot# 0 oferlN 1 Total Stories: '1 BiocuSubdivision; Builit Bder Name: Worst Case: No PlatBook: • Permit office: Rotate Angle: 0 Street: 316 SHADY LANE Jurisdiction: Cross Ventilation: County: St. Lucle Family Type: Single-family Whole House Fan: City, State, ZIP: PORT.ST. LUCIE , New/B isting: Addition FL, Comment: CLIMATE Design Location Design Temp TMY Site Int Design Temp - Heating Design Daily Temp 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH_MUNI - 39 90 70 75 299 52 Low BLOCKS Number Name Area - Volume 1 Blockl 1261 10008 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Ihfil ID Finished Cooled Heated 1 Main 1251 10008 Yes 1 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet _ 1 Slab -On -Grade Edge Insulalio Main 105 It 0 1251 fN - _� 1 0 0 ROOF # Type Roof Gable Roof Solar SA Emitt Emlit Deck Pitch Materials Area Area Color Absor. Tested Tested Insul. (deg) -- 1 Hip Composition shingles 135$ft. 0fe Light 0.8 No 0.9 No 0 22.6 ATTIC / v # Type Ventilation Vent Ratio (1 in) Area RBS - IRCC 1 Fun attic Vented 150 1251112 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing free TrussType Under Attic (Vented) Main 30 Blown 1251 fP 0.11 Wood 1/212019 2:16 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS aAdjacent Space Cavity Width In Height In Below Sheathing Framing SR-1/ahie Et Ft Arn Aolar 1 W Exterior Concrete Block `-Ext lnsul Main 4.0999 42, 8 335.6fe 0 0 0.5 0 _ 2 N Exterior Concrete Block - Fxt lnsul Main 4.0999 24 8 192.0 ft 0 0 0.5 0 3 E Exterior Concrete Block -Ext Insul Main 4.0999 42 8 336.0 fP 0 0 0.5 0 -4 S Exterior Concrete Block -Ext Insui Main 4.0999 34 6 272.0 ft-, 0 0 0.5 0 _5 W Exterior Frame- Wood Main 13- 20 B 160.0 ft' 0 0.25 0.6 0 6 N Exterior Frame - Wood Main 13 10 8 80.0 ft' 0 0.25, 0.5 0 _7 S Exterior Frame -Wood Main 13 10 8 80.0ft' 0 0.25 0.5 0 -8 N Garage Frame - Wood Main 11 24 8 192.0 ft' 0 0.25 0.5 0 DOORS # Dint Door Type Space - Storms U-Value Width Height, Area Ft In Ft In 1 E Insulated Main None .46 3 6 8 20 ft° WINDOWS Orientation shown is the entered Proposed orientation. / Wall - - - - Overhang V # Dint ID Frame Panes NFRC U-Factor SHGC Imp Area ,Depth, Separation Int Shade Screening. _ 1 W 1 Metal Single (Clear) Yes 0.75 0.45 N 9.0 ft' 2 ft 0 in 1 ft 4 in Drape slblinds None _ 2 E 3 Metal Single (Clear) Yes 0.79 0.45 N 9.0 ft2 ft 0 in 1 It 4 in Drapes/blinds None 3 E 3 Metal Single (Clear) Yes 0.79 0.45 N 45.0 ft' 2 ft 0 in 1 If 4 in Drapeslblinds None 4 E 3 Metal Single (Clear) Yes 0.79 0.45 N 16.0 ft' 2 ft 0 in 1 ft 4 in Drapes/blinds None 5 S 4 Metal Single (Clear) Yes 0.79 0.45 N 12.0 ft' 2 ft 0 in 1 It 4 in Drapeslblinds None 6 S 4 Metal Single (Clear) Yes 0.75 0.45 N 6.0 ft' 2 ft 0 in 1 ft 4 In Drapes/blinds None 7 S 4 Metal Single (Clear) Yes 0.75 0.45 N 6.0 ft2 2 ft 0 m 1 ft 4 In Drapes/blinds None 8 S 4 Metal Single (Clear) Yes 0.79 0.45 N 15.0 ft' 2 ft 0 in 1 ft 4 in Drapes/blinds None 9 W 5 Metal Single (Clear) Yes 0.79 0.45 N 20.0 ft' 2 ft 0 in 1 ft 4 in Drapes/blinds None 10 W 5 Metal Single (Clear) Yes 0.79 0.45 N 20.0 ft' 2 R-0 in 1 ft 4 in Drapes/blinds None 11 N 6 Metal Single (Clear) Yes. 0.79 0.45 N 20.0 ft' 2 ft 0 in 1 It 4 in Drapeslblinds None 12 S 7 Metal Single (Clear) Yes 0.70 0.45 N 36.0 ft' 2 ft 0 in 1 ft4 in Drapeslblinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 336fV 336 ft' 24 ft 8ft 11 INFILTRATION # Scope Method SlA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1167.6 64.1 120.55 .2578 7 112r2019 2:16 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 INPUT WIMMORV r1-IFrlC1 1ST RFPnRT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip HeaNReplaceme None COPS 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency. Capacity Air Flow SHR Block Ducts _ 1 Central UnitlReplacement for None SEER: 16 28.2 k8tulhr 846 cfm 0.85 1 sys#1 SOLAR HOT WATER SYSTEM FSEC ' Collector Storage Can # Company Name System Model # Collector Model # Area Volume FEF fN DUCTS Supply—: —Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 135 fl= - Attic 65 fill Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Progmmabl[e Thermostat. Y Ceiling Fans: ((�� Heating pC) Jan Feb [X) Mai Venting (] f ] AApp` [ [ �X1 May [ Jun [ ] Jul [7C� [) Aug (� [ ] (] Sep L J Oct rDU' [[ ]) Jan [ 1Feb [(�x1]. Mar l l [X) [ [ Jun O Jul [) Aug O Sep lxl Nov [ ] DDec ec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling OD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 • 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 • PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68. 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 PM 66 66 66 66 68 68 68 68 68 68 68 68 88 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(a Ibs1s .ft. 0 fP 0 ft 0.3 Main Name: Rating Compant: �IJe� (v i 11212019 2:16 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: ROBYN FOSTER Builder Name: with Street: 316 SHADY LANE Permit Office: City, State, Zip: PORT ST. LUCIE , FL , Permit Number: Y Owner: Jurisdiction: w Design Location: FL, Fort Pierce v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable Insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceilinglattic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. The insulation in any dropped ceiling/soffit Access openings, drop down stairs or knee wall doors to shall be aligned with the air barrier. unconditioned attic spaces shall be sealed. Walls The junction of the foundation and Sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be Insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alkinment with the air border. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and. framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including above -garage insulation. maintain permanent contact with the underside of and cantilevered subfloor decking, or floor framing cavity insulation floors) shall be permitted to be In contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawispace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts Innarrowcavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealingshall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind nlnlnn Showerltub on exterior The air barrier installed at exterior walls adjacent to showers and and wirina Exterior walls adjacent to showers and tubs shall wall tubs shall separate them from the showers and tubs. be insulated. Electricallphone box of The air barrier shall be Installed behind electrical or communication exteriorwalls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be'sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill volds Ill air of log walls shall be in accordan th a. In addition, inspection ce wi a prowsrons of ICG400. V=019 2:16 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. Addition 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 3. No. of units (if multiple -family) 3. 1 c) AHU location Aftic/Attic 4. Number of bedrooms 4. 3 5.. Is this a worst case? (yes/no) 5. No 6. Conditioned floor area (sq. ft.) 6. 1251 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.786 b) Solar Heat Gain Coefficient (SHGC) 7b.. '0.450 c) Area 7c. 214.0 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) ga. 0.0 b) Wood, raised (R-value) 9b. c) Concrete, raised (R-value) 9c. 10. Wall type and insulation: A. Exterior. 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 10A1. 13.0 10A2. 4.1 10131. 11.0 10B2. 13. Cooling system: Capacity28.2 ,a) Split system SEER b) Single package SEER c) Ground/water source SEERICOP d) Room unitlPTAC EER e) Other 16.0 14. Heating system: Capacity27.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE 0 Other 15. Water heating system a) Electric resistance EF b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ 0 Heat recovery unit HealRec% g) Other 16. HVAC credits claimed (Performance Method) a) Ceiling fans Yes 11a. ' 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. Yes e) Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Address of New Home: 316 SHADY LANE City/FL Zip: PORT ST. LUCIE. FL 1020119 2:16:05 PM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1 Job: wrightsoft° Load.-�ort Fo RECEIVED Date: Entire House By. Ars ofvero beach JAN 0 4 2019 28001e 1, wre bead%032960 Phone: 772-794-7215 ST. Lucie CDUnt Permittln Project• • For. Robin Foster 316 shady'lane, poet st lucie, fl 34952 -41 Qesign Information Htg clg Infiltration Outside db (OF) 42 90 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD CF) 28 15 Fireplaces 0 Dailyrange - L Inside humidity (%) 30 50 Moisture difference (grAb) 1 61 HEATING EQUIPMENT Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Airflow factor Static pressure Space thermostat 80AFLIE 0 Btuh 0 Btuh 0 OF 917 cfin 0.050 chBtuh 0 in H2O COOLING EQUIPMENT Make Trade Cond Coil AHRI ref Efficiency Sensible cooling Latent cooling Total cooling Actual airflow Airflowfactor Static pressure Load sensible heat ratio 0 SEER 0 Btuh 0 Btuh 0 Btuh 917 cfrn 0.042 dmlBtuh 0 in H2O 0.82 ROOM NAME Area Htg load Clg load HtggAVF CIgAVF OF) (stun) (Btuh) (cIm) (cfinn) Room1 1300 18237 21611 917 917 Entire House d 1300 18237 21611 917 917 Other equip loads 0 0 Equip. @ 0.95 RSM 20530 Latent cooling 4656 T11T111 O 4Onn 4OOo9 ..4 O1 ! 41 IIAO WUY IVLv/ 4J 10/ OIr Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrightsoft• 2018-Deo2015:0530 .,.,., ._...,,,.,.., Righ4SdL-SUrYversa1201818.0.19RSU27371 Page ACCk c:WsemWtoddOesWnpload CaImTSL2Stonnq Calc=MI8 FrortDoorfams: N +� wrightsoft° Building Analysis o te1 Entire House By. Ars of veto beach For. Robin Foster 316 shady lane, poet st lucie, fi 34952 Design • • • Location: Indoor Heating Cooling Fort Pierce, FL, US Indoor temperature (°F) 70 75 Elevation: 25 ft Deal in TD (°F) 28 15 Latitude: 27°N Relative humidity (%) 30 50 Outdoor. Heating Cooling Moisture difference(gdlb) 1.1 61.5 Dry bulb (°F) 42 90 Infiltration: Dailyrange °F) - 15 (L ) Method Simplified Wef bulb (°�) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 %Heating Component Btui Btuh %of load Walls 2.5 3756 , 20.6 Glazing 16.0 4309 23.6 Doors 0 0 0 Ceilings 0.9 - 1165 6A Floors 0.5 618 3.4 Infiltration 2.8 4800 26.3 Ducts 3589 19.7 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 1 18237 100.0 " 'Cooling.,. Component Btuh/ft2 Btuh %of load Walls 2.2 3219 14.9 Glazing 35.1 9473 43.8 Doors 0 0 0 Ceilings 1.7 2184 10.1 Floors 0.3 331 1.5 Infiltration 0.8 1314 6.1 Ducts 5088 23.5 Ventilation 0 0 Internal gains 0 0 Blower 0 0 Adjustments 0 ` Total 21611 100.0 Latent Cooling Load =4656 Btuh Overall U-value=0.091 Btuh/fi22F Data entries checked. y -F;J- wrightsoft' 2018-Deo-2015:05:30 -` Right-SUte®Uricersai201818D.19 RSU27371 page 1 AC-Ok C:WserslsdtoddrDesMopVLoad Calm'PSL2StowW CaIc=MJ8 Frori DoorfaresA Cote onent Constructions, Job: +� wrightsoft• p Date: Entire House By: Ars of vero beach 280D W 1, vero beach 032960 PMre:772-794-7216 ieroject intormation For. Robin Foster 316 shady lane, poet st lude, 1134952 Design Conditions Location: Indoor. Heating Cooling Fort Pierce, FL, US Indoor temperature (OF) 70 75 Elevation: 25 It Design TD (•F) 28 15 Latitude: 270N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr4b) 1.1 61.5 Dry bulb (•F) 42 90 Infiltration: Daily range (OF) - 15 (L ) Method Simplified Wet bulb (OF) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions or Area u-value Inset H Htg HTM Loss Cig HTM Gain 82 RktV 'F M?F/BM BUM BM shhV BM Walls 12C-0sw. Fnn wall, stuom ext, r-13 cav ins, 7k4" wood frm, 16" o.c. stud Partitions (none) Windows 1 D-c2ow. 2 glazing, dr outr, air gas,,Ad fbn mat, dr innr, 114" gap, 1/8"thk; 6.67 it head ht Doors (none) Ceilings 16B30ad: Attic ceiling, asphalt shingles roof mat, r31 roof ins, r30 cal ins Floors 19C-19cscp: Rr floor, fnn fir, 6"thins, carpet fir fnsh, r-2 e)d ins, r-19 cav ins, tight crlvl ovr, r-11 wall insul n 342 0.091 13.0 2.55 871 2.18 747 e 342 0.091 13.0 2.55 871 2.18 747 s 342 0.091 13.0 2.55 871 2.18 747 W 448 0.091 13.0 2.55 1142 2.18 978 all 1474 0.091 13.0 2.55 3756 2.18 3219 n 90 0.570 0 16.0 1436 20.3 1826 e 90 0.570 0 16.0 1436 62.4 5613 s 90 0.570 0 16.0 1436 22.6 2035 all 270 0.570 0 16.0 ` 4309 35.1 9473 1300 0.032 30.0 0.90 1165 1.68 2184 1300 0.049 30.0 0.4.8 618 0.25 331 -F4d- wright aft- 2018-Deo-2015.0530 . .....,,,.,., Mgt1-Sdte9Udversa1201818.0.19 RSU27371 Pagel ACCA C:Wser wtoddlDesldopload CaImTSL251onnp Calc=M18 Frorl Doorfaces: N Ii+ wrightsofte Cor:=:rjnent Constructions o Room9 By. Ars of vero beach 2800 is 1, wrO beatlka 32960 Phore:772-794-7215 Project• • For. Robin Foster 316 shady lane, poetst lucie, fi 34952 Design • • • Location: Indoor. Heating Cooling Fort Pierce, FL, US Indoor temperature (OF) 70 75 Elevation: 25 it Design TD (OF) 28 15 Latitude: 270N Relative humidity (o/u) 30 50 Outdoor: Heating Cooling Moisture difference (grAb) 1.1 61.5 Dry bulb (OF) 42 90 Infiltration: Daily range (OF) 15 (L ) Method Simplified Wet bulb (OF) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value InsulR Htg HTM Loss CIg HTM Gain R BUMUF WIFA" BUM Btih BWtlg' am Walls 12C-0sw. Fnn wall, stucco ext, r-13 aev ins, 2'k4" wood frm, 16" o.o n 342 0.091 13.0 2.55 871 2.18 747 stud a 342 0.091 13.0 2.55 871 2.18 747 s 342 0.091 13.0 2.55 871 2.18 747 W 448 0.091 13.0 2.55 1142 2.18 978 all 1474 0.091 13.0 155 3756 2.18 3219 Partitions (none) Windows 1 Dc2ow. 2 glazing, clr outr, air gas, vd fnn mat, clr innr, 1/4"gap, 1/8" thk; 6.67 ft head ht Doors (none) Ceilings 16B30ad: Attic ceiling, asphalt shingles roof mat, r31 roof ins, r30 veil Ins Floors 19C-19cscp: Flrfloor, fnn fir, 6"thkns, carpet flrfnsh, r-2 ext ins, r-19 cav ins, tight cnM ovr, r-11 wall insul n 90 0.570 0 16.0 1436 20.3 1826 .a 90 0.570 0 16.0 1436 62.4 5613 s 90 0.570 0 16.0 1436 22.6 2035 all 270 0.570 0 16.0 4309 35.1 9473 1300 0,032 30.0 0.90 1165 1.68 2184 1300 0.049 30.0 0.48 618 0.25 331 wrightsoR• 2018-Deo-2015:0530 �+ u.•, .RIgK-SWe®UAwrsa1201818.0.19RSU27371 Pege2 ACCA C:Wsers..lsdloddlDesld pPto'ed CelmWSL2.5toarm Ca1c=MI8 FrortDoorfaws: N +�} wrightsoft' Right-J®Worksheet o m1 Entire House By. Ars of vero beach 2800 w 1. vero beadl fl 32960 Ptnre: 772-794-7215 1 Raw name Entire House Room1 2 EVosedveil 224.0 ft 224.0 ft 3 Room helgN 16.0 ft d 16.0 ft heaVcod 4 Roomdmensims 10.0 x 130.0 ft 5 Roan area 1300.0 ft 1300.0 ft Ty Canstrur m U-wlue or HTM rea A(ftF) load Area (f* Load number (BWt14 L9 (Bt "n or perimeter (IQ (Btuh) or perimeter (1) (Btuh) Heat Cod Gloss NIPS Heat Cool Gross I Nee. Heat Cool 6 0.091 n 255 218 432 342 971 747 432 342 671 747 T-12C-Dw G 1D C20W 0.570 n 15.96 ' 2029 90 0 1436 1826 90 . 0 1436 1026 ev 0.091 a 255 Z16 432 342 971 747 432 342 871 747 _12C-O G ID-C2w 0.670 a 15.98 62.36. 90 0 1436 5613 90 0 1436 5613 11 %E--G 12C-Ow Q091 s 255 218 . '432 342 871 747 432 342 871 747 1D40W 0.570 s 15.96 72.61 90 0 1436 2035 93 0 1436 2035 w 12C-0sv 0.091 w 255 218 448 448 1142 978 448 448 1142 978 C 16B30ad 0.032 - 0.90 1.68 1300 1300 1165 2154. 13m 1300 1165. 2184 F 19C-19cxp 0.049 - 0.48 025 13DO 1300 618 331 1300 1300 618 331 6 c)AED emason 0 0 Envelope loss/gain 9848 15208 9946 1520B 12 a) Infiltration 4800 1314 4800 1314 b) Rmm ventilation 0 0 0 0 13 InteOW gains: omlpmts@ 230 0 0 0 0 Appiianmyodw 0 0 SubbW Qines6tr113) 14649 16522 14141 16522 LesseAemalload 0 0 0 0 LestransW 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 14649 16522 14649 16522 15 DuCloads 24% 31% 3589 5088 24-A 31% 3589 5088 Tofalroom load 18237 21611 18237 21611 Airn: mm,(Um) 917 917 917 917 Calculations approved byACCAto meet all requirements of Manual J Sth Ed. "f`�" wrlghcsof_e- 2018-Dea2015.05:30 RIgtt-Sole® UNversa1201818.0.19 RSU27371 Page 1 I&k C:WseraVOWdUasldoptoad CaIm7SL 2.5 tong Calc=MJ8 FrorlDoorfams: N