Loading...
HomeMy WebLinkAboutEVALUATION REPORTProduct Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC. SCgN Sf . QYN�o 26 Ga. GulfRibTM Roof Panel over 95/32" Plywood �4C/e Coup tk Florida Product Approval #11651.23 R3 Florida Building Code 2017 Per Rule 61 G20-3 Method: 1 —D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61G20-3.005(1)(d) HVHZ Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. 14429 SW 2nd Place, Suite G30 Newberry, FL 32669 Engineer Evaluator: Dan Kuhn, P.E. #75519 Florida Evaluation ANE ID: 10743 Validator: Locke Bowden, P.E. #49704 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1 — 5 FL# 11651.23 R3 • OCTOBER 5, 2017 ,,, 11111111II�, ��cENs• yy': F, 51� 9: % STATE O�Fi9 .c4 0 ApO P 1�0NAL So 1%`% ' / I I n 1 1 11 j 11O/O5/2017 A,./. �\\W\,e Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2, 1518.9, 1523.6.5.2.4. Product Description: GulfRibTM, 3/a" Rib Roof Panel, Minimum 26 Ga. Steel, 36" Coverage, through fastened roof panel over minimum 15/32" Plywood Decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2017 Section 1507.4.3. Paint Finish Optional Yield Strength: Min. 80.Oksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 36" Coverage Rib Height: 3/a" Major Rib at 9" O.C. Panel Fastener: #9-15 HWH 1.5" with sealing washing or approved equal 1/4" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4 Substrate Description: Minimum 15/32" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2017. Design Uplift Pressures: Table "A" Maximum Total Uplift Design Pressure 71.75 psf 159.25 psf Fastener Pattern 9"-9"-9"-9" 6.5"-2.5"-6.5"- 2.5"6.5"-2.5"-6.5" Fastener Pattern Spacing 24" O.C. 12" O.C. Design Pressure includes a Safety Factor = 2.0. Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2, 1518.9, 1523.6.5.2.4. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: • TAS 125-03 • UL 580-06 - Test for Uplift Resistance of Roof Assemblies • UL 1897-12 - Uplift Test for Roof Covering Systems. • TAS 100-95 - Test Procedure for Wind and Wind Driven Rain Resistance of Discontinuous Roof Systems • TAS 110-00 - Accel. Weathering ASTM G 155 / Salt Spray ASTM B 117. Reference Data: 1. TAS 125-03: UL 580-94 / 1897-98 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No.117-0062T-07A-C Dated 02/19/2007 2. TAS 100-95 Farabaugh Engineering & Testing, Inc. (FBC Organization # TST-1654) Report No. T126-07, Dated 02/26/2007 Report No. T270-08, Dated 10/13/2008 3. TAS 110-00: Valspar Fluropon coated metal panel testing A) ASTM G 26 by PRI Asphalt Technologies dated 01/19/2004 B) ASTM B 117 by PRI Asphalt Technologies dated 01/19/2004 4. Certificate of Independence By Dan Kuhn, P.E. (FL# 75519) @ Kuhn Engineering, LLC (FBC Organization # ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test standard. 3. ASTM G 26 is equivalent to ASTM G 155. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005(3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1515.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details and RAS 133. Underlayment: Shall comply with Florida Building Code 2017 section 1518.2, 1518.3, 1518.4 Fire Barrier: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. w ENGINEER LOAD TABLE: 26 Ga. Gulf RibTM Panel over 15/32" Plywood Buildings having a Roof Mean Height <_ 20'-0"; Roof Slope: 2"/12" - 12"/12" Gable or Hip Roof; Wind Speeds 120- 180mph, Exposure C, Risk Category II, Enclosed Building, based on Florida Building Code 2017. 120 130 140 150 160 170 180 WIIND FASTENER SUBSTRATE SPEED (MIN. Penetration) (MIN. 15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER SPACING SPACING SPACING SPACING SPACING SPACING SPACING ZONE 1 #9-15x1.5" Plywood 24", TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 1 ZONE 2 #9-150.5" Plywood 24", TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 1 ZONE 3 #9-15x1.5"' Plywood 24", TYPE 1 24", TYPE 1 24", TYPE 1 12", TYPE 2 1 12", TYPE 2 12", TYPE 2 12", TYPE 2 1.) PANEL DESCRIPTION: GULFRIBTM, MIN. 26 GA., GRADE 80, 36"COVERAGE, 3/4" TALL. 2.) PANEL FASTENER: 99-15X1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL 3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: 71.75 PSF 0 24" O.C. FASTENER SPACING TYPE I FASTENER PATTERN, 159.25 PSF @ 12" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. 4.) PLYWOOD DECKING: MIN.15/32" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017. 5.) ROOF SLOPE: ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10 (KD = 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2017. ,VUNEZ ZONES T-j --------------• \\ \\ RIDGE — / ZONE ♦ \\ / __ \ Note: Dimension (a) is defined as 10e/ of the minimum width of the building or 40% of the mean height of the roof, whichever is smaller, however, (a) cannot be �e less than either4% of the minimum width of the building or 3 feet. ZO \ Z GABLE ROOF Ti a _ I 1- 1 _/ —,}a I j I --RIDGE a "--------------------- i rya I ZONE 1 FL# 11651.23 R3 • OCTOBER 5. 2017 Cont Tape Seal for use on #9-15 x 1-1/Y w/Sealer Washer at 24' O.C. #9-15 x 1-1/2' w/Sealer Washer at 12' O.C. less MIAM4DAD5 MIAMI-DADS COUNTY PRODUCT CONTROL SECTION ' 11805 SW 26 Slmet, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) eiiiv.miamidade.aavlecmmmv Gulf Coast Supply & Manufacturing LLC. 4020 SW 4490' St. Horseshoe Beach, FL. 32648 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance proposes. If this product or material fails to perform in the accepted maimer, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 26 ga. GulfRib Roof Panel over I5/32" Plywood deck LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for tennination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. APPaOYED NOA No.: 14-0520.01 Expiration Date: 10/23/19 Approval Date: 10/23/14 Page 1 of 6 ROOFING SYSTEM APPROVAL: Cate2ory Sub -Category: Material: Deck Type: Maximum Design Pressure Roofing Metal, Panels (Non -Structural) Steel Wood -159.25 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specifications Description 26 ga. Gu11Rib Roof Length: various TAS 110 26ga. Steel, Flouropan Coated, Ribbed panel. Panel Height: 3/4" Width: 36" (coverage) Thickness: 26ga. (0.0185") MANUFACTURING LOCATION: 1. EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Construction Materials VLS-004-02-01 ASTM G155 02/22/13 Technologies VLS-005-02-01 ASTM B 117 02/22/13 Farabaugh Engineering and Testing T270-08A TAS 100 07/18/13 T126-07A TAS 100 07/18/13 Force Engineering and Testing, Inc. 117-0062T-07A-C TAS 125 07/26/13 NOA No.: 14-0520.01 Expiration Date: 10/23/19 Approval Date: 10/23/14 Page 2 of 6 APPROVED ASSEMBLIES: System: 26Ga. GulfRib Roof Panel Deck Type: Wood, Non -insulated Deck Description: New Construction 19/32" or greater plywood or wood plank, or for re -roofing 15/32" or greater plywood. Slope Range: 2": 12" or greater Maximum Uplift See Table A below Pressure: Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d almular ring shank nails spaced 6" o.c. Ill reroofing, where the deck is less than 19/32" thick (Mininmm 15/32") The above attachment method must be in addition to existing attachment. Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4" side -lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and 12 gauge 1 1/d' annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll or any approved underlayment having a current NOA. Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation # 1. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with the current published installation instructions and details in Gulf Coast Supply & Manufacturing LLC's Installation Manual. Metal Panels and Install the "26Ga. GulfRib Roof Panel " and accessories in compliance with Gulf Coast Accessories: Supply & Manufacturing LLC's current published installation instructions and details. Flashing, penetrations, valley construction and other details shall be constructed in compliance with the minimum requirements provided in Roofing Application Standards RAS 133. 26Ga. GulfRib Roof Panels shall be fastened with a minimum of 49-15 x 1-1/2" woodgrip corrosion resistant screws. Fasteners shall of sufficient length to penetrate through the sheathing a minimum of 3/1G. Fasteners shall be place in accordance with fastener detail herein as follows: TABLE A MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeter and Corner' Maximum Design Pressures 71.75 psf 159.25 psf Maximum Clip Spacing 24" o.c. 12" o.c. 1. Extrapolation shall not be allowed NOA No.: 14-0520.01 Expiration Date: 10/23/19 Approval Date: 10/23/14 Page 3 of 6 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). 3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in Roofing Application Standard RAS 133. 4. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or model. MIAMI•DADE COUNTY 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.: 14-0520.01 Expiration Date: 10/23/19 Approval Date: 10/23/14 Page 4 of 6 PROFILE DRAWINGS DETAIL A FIELD CONDITION ling a min. is. (optional) NOA No.: 14-0520.01 Expiration Date: 10/23/19 Approval Date: 10/23/14 Page 5 of 6 DETAIL A (CONTINUED) #9 Woodscrews long enough to penetrate through the sheathing a min. of 16" 4" -14 x 8" stitch screws. (optional) 12" o.c. for-159.25psf PERIMETER AND CORNER CONDITION END OF THIS ACCEPTANCE NOA No.: 14-0520.01 Expiration Date: 10/23/19 Approval Date: 10/23/14 Page 6 of 6